REVIEWED BLD BLD2021-0047+Structural_Analysis_or_Calculations+1.13.2021_1.28.01_PM+1988301Harriott Valentine Engineers Inc. STRUCTURAL CALCULATIONS Project: Goodman residence 8010 181 st PL SW Edmonds, WA 98026 Architect: 1-12D Architecture + Design 23020 Edmonds Way #113 Edmonds, WA 98020 Structural Engineer: Harriott Valentine Engineers, Inc. 1932 First Avenue, Suite 720 Seattle, WA 98101 tel. 206-624-4760 '20 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel. 206-624-4760 1 fax 447-6971 Harriott Valentine Engineers Inc. CRITERIA O'Donnell Remodel Gravity Loads ex. roof dead 2x10 @ 24 1/2" plywood R38 insulation 5/8" gyp. wallboard asphalt shingles slope factor miscellaneous total dead + live floor dead 3/4" hardwood 3/4" plywood (2) 2x8 @ 16 acoustic insulation 1/2" plywood miscellaneous total dead + live walls wood siding 1/2" plywood 2x6 @ 16"oc R21 insulation 1/2" gyp. wallboard miscellaneous total dead Trellis dead 4x8 @ 24 3/4" plywood miscellaneous total dead + live porch/deck dead 2x10 @ 16" 1/2" plywood miscellaneous total dead + live 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel 206-624-4760 1 fax 447-6971 1.90 live snow 1.50 1.10 2.80 2.50 0.50 1.70 14% 12.00 psf 37.00 psf 3.00 2.30 4.40 1.00 1.50 1.80 13% 14.00 psf 54.00 psf 25.00 psf live residential 40.00 psf 3.00 1.50 1.70 0.80 2.20 0.80 8% 10.00 psf 10.00 psf 3.00 live snow 2.30 1.70 24% 7.00 32.00 psf 25.00 psf 2.80 live residential 60.00 psf 1.50 3.70 46% 8.00 68.00 psf Harriott Valentine Engineers Inc. Lateral wind wind importance factor basic wind speed wind exposure topographical factor (Kzt) seismic seismic importance factor latitude longitude mapped spectral response accel. at short periods (Ss) seismic design category response modification factor (R) 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel 206-624-4760 1 fax 447-6971 1.0 110 mph B 1.67 1.0 47.679 ° -122.287 ° 1.288 g D 6.5 (from USGS) ®%t1 ROOF FRAMING PLAN (MAIN FLOOR WALLS) S22 ed. 1/P -1'-T �Ii F JOB SUMMARY REPORT Goodman Roof - vaulted ceiling Member Name Results Current Solution Comments Ex. Rafters Passed 1 piece(s) 2 x 8 Hem -Fir No. 1 @ 24" OC R1 Passed 1 piece(s) 5 1/8" x 18" 24F-V4 DF Glulam R2 Passed 1 piece(s) 3 1/2" x 11 7/8" 24F-V4 DF Glulam Trellis rafters R5 Passed 11 piece(s) 4 x 8 Hem -Fir No. 1 @ 24" OC R4 Passed 1 piece(s) 6 x 10 Douglas Fir -Larch No. 1 R3 Passed 1 piece(s) 6 x 12 Douglas Fir -Larch No. 1 Deck Member Name Results Current Solution Comments Deck joists Passed 1 piece(s) 2 x 4 Hem -Fir No. 1 @ 16" OC Edge beams Passed 1 piece(s) 6 x 8 Douglas Fir -Larch No. 1 ForteWEB Software Operator Job Notes Todd Fisher Harriott Valentine Engineers (206) 624-4760 trisher@harriottvalentine.com 8/21/2020 9:13:55 PM UTC ForteWEB v3.0 Weyerhaeuser File Name: Goodman Page 1 / 9 a" O R T CM MEMBER REPORT PASSED Roof - vaulted ceiling, Ex. Rafters 1 piece(s) 2 x 8 Hem -Fir No. 1@ 24" OC 12 4F 2' 6" 0 Sloped Lengih: 16' 5 1/8' 12' 6" All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 699 @ 2' 7 3/4" 2241 (3.50") Passed (31%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 446 @ T 4 3/8" 1251 Passed (36%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 1438 @ 9' 2 5/16" 1694 Passed (85%) 1.15 1.0 D + 1.0 S (Alt Spans) Live Load Defl. (in) 0.436 @ 9' 11/16" 0.671 Passed (L/370) 1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in) 0.644 @ 9' 15/16" 1 0.895 1 Passed (L/250) 1 1.0 D + 1.0 S (Alt Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Overhang deflection criteria: LL (2L/240) and TL (2L/180). Upward deflection on left cantilever exceeds overhang deflection criteria. • Allowed moment does not reflect the adjustment for the beam stability factor. • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Beveled Plate - SPF 3.50" 3.50" 1.50" 235 371 464 1070 Blocking 2 - Beveled Plate - SPF 3.50" 3.50" 1 1.50" 159 257 322 738 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 5' 1" o/c Bottom Edge (Lu) 16' 5" o/c -Maximum allowable bracing intervals based on applied load. Vertical Load Location (Side) Spacing Dead (0.90) Roof Live (non -snow: 1.25) Snow (1.15) Comments 1 - Uniform (PSF) 0 to 15' 7" 24" 12.0 20.0 25.0 ROOF Notes Member Length : 16' 7 9/16" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2015 Design Methodology : Aso Member Pitch : 4/12 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -parry certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/wGodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Todd Fisher Harriott Valentine Engineers (206) 624-4760 trisher@harriottvalentine.com 8/21/2020 9:13:55 PM UTC ForteWEB v3.0, Engine: V8.1.3.1, Data: V8.0.0.0 Weyerhaeuser File Name: Goodman Page 2 / 9 a" O R T CM MEMBER REPORT PASSED Roof - vaulted ceiling, R1 1 piece(s) 5 1/8" x 18" 24F-V4 DF Glulam Overall Length: -� 11 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 9344 @ 4" 11980 (5.50") Passed (78%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 7940 @ 23' 11 1/2" 18742 Passed (42%) 1.15 1.0 D + 1.0 S (All Spans) Pos Moment (Ft-Ibs) 57434 @ 12' 11 7/16" 60007 Passed (96%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.945 @ 12' 11 7/16" 1.263 Passed (L/321) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 1.470 @ 12' 11 7/16" 1 1.683 1 Passed (L/206) 1 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 0.94 that was calculated using length L = 25' 3". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Supports IV Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Stud wall - SPF 5.50" 5.50" 4.29" 3334 4805 6010 14149 Blocking 2 - Stud wall - SPF 5.50" 5.50" 4.00" 3122 4470 5590 13182 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 12' 5" o/c Bottom Edge (Lu) 25' 11" o/c -Maximum allowable bracing intervals based on applied load. Dead Roof Live Snow Vertical Loads Location (Side) Tributary Width (0.90) (non -snow: 1.25) (1.15) Comments 0 - Self Weight (PLF) 0 to 25' 11" N/A 22.4 1 - Uniform (PLF) 0 to 25' (Front) N/A 117.5 185.5 232.0 Linked from: Ex. Rafters, Support 1 2 - Uniform (PLF) 0 to 25' (Front) N/A 117.5 185.5 232.0 Linked from: Ex. Rafters, Support 1 System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Member Pitch : 0/12 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Todd Fisher Harriott Valentine Engineers (206) 624-4760 trisher@harriottvalentine.com 8/21/2020 9:13:55 PM UTC ForteWEB v3.0, Engine: V8.1.3.1, Data: V8.0.0.0 Weyerhaeuser File Name: Goodman Page 3/9 a" O R T CM MEMBER REPORT PASSED Roof - vaulted ceiling, R2 1 piece(s) 3 1/2" x it 7/8" 24F-V4 DF Glulam Overall Length: 14' a 1 0 14' n All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. 0 Design Results Actual @ Location Allowed Result 0 LDF Load: Combination (Pattern) Member Reaction (Ibs) 8597 @ 4" 12513 (5.50") Passed (69%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 8582 @ 1' 5 3/8" 8444 Passed (102%) 1.15 1.0 D + 1.0 S (All Spans) Pos Moment (Ft-Ibs) 10019 @ 1' 6" 18920 Passed (53%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.155 @ 6' 9/16" 0.444 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.250 @ 6' 15/16" 1 0.667 1 Passed (L/641) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 13' 4". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Column - DF 5.50" 5.50" 3.78" 3113 4385 5484 12982 None 2 - Column - DF 5.50" 5.50" 1.50" 362 420 526 1308 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 14' o/c Bottom Edge (Lu) 14' o/c -Maximum allowable bracing intervals based on applied load. Dead Roof Live Snow Vertical Loads Location (Side) Tributary Width (0.90) (non -snow: 1.25) (1.15) Comments 0 - Self Weight (PLF) 0 to 14' N/A 10.1 -- -- 1 - Point (lb) 1' 6" (Front) N/A 3334 4805 6010 Linked from: R1, Support 1 System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASO Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Todd Fisher Harriott Valentine Engineers (206) 624-4760 trisher@harriottvalentine.com 8/21/2020 9:13:55 PM UTC ForteWEB v3.0, Engine: V8.1.3.1, Data: V8.0.0.0 Weyerhaeuser File Name: Goodman Page 4 / 9 a" O R T CM MEMBER REPORT PASSED Roof - vaulted ceiling, Trellis rafters R5 1 piece(s) 4 x 8 Hem -Fir No. 1@ 24" OC r 0 Overall Length: 19' 10 15/16' 12' 315116" r 5, 9„ 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 866 @ 14' 3/16" 4961 (3.50") Passed (17%) 1.0 D + 1.0 S (Adj Spans) Shear (Ibs) 441 @ 13' 3 3/16" 2918 Passed (15%) 1.15 1.0 D + 1.0 S (Adj Spans) Moment (Ft-Ibs) -1112 @ 14' 3/16" 4283 Passed (26%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.180 @ 19' 10 15/16" 0.590 Passed (2L/786) 1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in) 0.195 @ 19' 10 15/16" 1 0.786 1 Passed (2L/728) 1.0 D + 1.0 S (Alt Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Overhang deflection criteria: LL (2L/240) and TL (2L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Stud wall - SPF 3.50" 3.50" 1.50" 90 284 355 729 Blocking 2 - Stud wall - SPF 3.50" 3.50" 1 1.50" 189 542 677 1408 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 19' 11" o/c Bottom Edge (Lu) 19' 11" o/c -Maximum allowable bracing intervals based on applied load. Vertical Load Location (Side) Spacing Dead (0.90) Roof Live (non -snow: 1.25) Snow (1.15) Comments 1 - Uniform (PSF) 0 to 19' 10 15/16" 24" 7.0 20.0 25.0 TRELLIS ROOF Notes System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2015 Design Methodology : Aso Member Pitch : 0/12 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -parry certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/wGodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Todd Fisher Harriott Valentine Engineers (206) 624-4760 trisher@harriottvalentine.com 8/21/2020 9:13:55 PM UTC ForteWEB v3.0, Engine: V8.1.3.1, Data: V8.0.0.0 Weyerhaeuser File Name: Goodman Pages/9 a FORTE'M3 MEMBER REPORT Roof - vaulted ceiling, R4 1 piece(s) 6 x 10 Douglas Fir -Larch No. 1 PASSED 1 0 Overall Length: 13 15' All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1768 @ 2" 8181 (3.50") Passed (22%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 1513 @ 1' 1" 6810 Passed (22%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 6339 @ 7' 6" 10703 Passed (59%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.327 @ 7' 6" 0.489 Passed (L/539) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.434 @ 7' 6" 0.733 Passed (L/406) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Stud wall - SPF 3.50" 3.50" 1.50" 437 1065 1331 2833 Blocking 2 - Stud wall - SPF 3.50" 3.50" 1 1.50" 437 1065 1331 2833 Blocking • BiocKmg Naneis are assumeo to carry no ioads applied oirecuy anove tnem ano the run ioao is appnea to the member Deing oesigneo. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 15' o/c Bottom Edge (Lu) 15' o/c -Maximum allowable bracing intervals based on applied load. Dead Roof Live Snow Vertical Loads Location (Side) Tributary Width (0.90) (non -snow: 1.25) (1.15) Comments 0 - Self Weight (PLF) 0 to 15' N/A 13.2 Linked from: Trellis 1 - Uniform (PLF) 0 to 15' (Front) N/A 45.0 142.0 177.5 rafters R5, Support 1 System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Todd Fisher Harriott Valentine Engineers (206) 624-4760 trisher@harriottvalentine.com 8/21/2020 9:13:55 PM UTC ForteWEB v3.0, Engine: V8.1.3.1, Data: V8.0.0.0 Weyerhaeuser File Name: Goodman Page 6 / 9 a FORTE'M3 MEMBER REPORT Roof - vaulted ceiling, R3 1 piece(s) 6 x 12 Douglas Fir -Larch No. 1 PASSED 1 0 Overall Length: 13 15' All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 3368 @ 2" 8181 (3.50") Passed (41%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 2806 @ P 3" 8244 Passed (34%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 12074 @ 76" 15684 Passed (77%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.351 @ 7' 6" 0.489 Passed (L/501) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.466 @ 7' 6" 0.733 Passed (L/378) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Total 1 - Stud wall - SPF 3.50" 3.50" 1.50" 829 2033 2539 5401 Blocking 2 - Stud wall - SPF 3.50" 3.50" 1 1.50" 829 2033 2539 5401 Blocking • BiocKmg Naneis are assumed to carry no ioads applied direcuy anove tnem and the run ioad is appuea to the memoer Deing designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 15' o/c Bottom Edge (Lu) 15' o/c -Maximum allowable bracing intervals based on applied load. Dead Roof Live Snow Vertical Loads Location (Side) Tributary Width (0.90) (non -snow: 1.25) (1.15) Comments 0 - Self Weight (PLF) 0 to 15' N/A 16.0 Linked from: Trellis 1 - Uniform (PLF) 0 to 15' (Front) N/A 94.5 271.0 338.5 rafters R5, Support 2 System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Todd Fisher Harriott Valentine Engineers (206) 624-4760 trisher@harriottvalentine.com 8/21/2020 9:13:55 PM UTC ForteWEB v3.0, Engine: V8.1.3.1, Data: V8.0.0.0 Weyerhaeuser File Name: Goodman Page 7 / 9 a" O R T CM MEMBER REPORT PASSED Deck, Deck joists 1 piece(s) 2 x 4 Hem -Fir No. 1@ 16" OC Overall Length: lr 4' 9" i 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 255 @ 2 1/2" 1063 (1.75") Passed (24%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 200 @ 7" 525 Passed (38%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 290 @ 2' 8" 429 Passed (68%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.139 @ 2' 8" 0.164 Passed (L/424) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 0.165 @ 2' 8" 1 0.246 1 Passed (L/357) 1 1.0 D + 0.75 L + 0.75 S (All Spans) TJ-Pro'"" Rating N/A I N/A I N/A I N/A • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on NDS. • No composite action between deck and joist was considered in analysis. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Total 1 - Stud wall - HF 3.50" 1.75" 1.50" 43 213 89 345 1 3/4" Rim Board 2 - Stud wall - HF 3.50" 1.75" 1 1.50" 43 213 89 345 1 3/4" Rim Board • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 5' 1" o/c Bottom Edge (Lu) 5' 1" o/c -Maximum allowable bracing intervals based on applied load. Vertical Load Location (Side) Spacing Dead (0.90) Floor Live (1.00) Snow (1.15) Comments 1 - Uniform (PSF) 0 to 54" 16" 12.0 60.0 25.0 DECK System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2015 Design Methodology : Aso Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Todd Fisher Harriott Valentine Engineers (206) 624-4760 trisher@harriottvalentine.com 8/21/2020 9:13:55 PM UTC ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0 Weyerhaeuser File Name: Goodman Page 8 / 9 a FORTE"M3 MEMBER REPORT Deck, Edge beams 1 piece(s) 6 x 8 Douglas Fir -Larch No. 1 PASSED 0 Overall Length: 13 13' 9" All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1439 @ 4" 14609 (4.25") Passed (10%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 1173 @ P 1" 4675 Passed (25%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 4332 @ 6' 10 1/2" 5157 Passed (84%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.362 @ 6' 10 1/2" 0.436 Passed (L/434) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 0.453 @ 6' 10 1/2" 1 0.654 1 Passed (L/347) 1.0 D + 0.75 L + 0.75 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Total 1 - Column - DF 5.50" 4.25" 1.50" 292 1098 459 1849 1 1/4" Rim Board 2 - Column - DF 5.50" 4.25" 1 1.50" 292 1098 459 1849 1 1/4" Rim Board • Kim Boara is assumes to carry all ioaas appl eo oirecuy above it, Dypassmg the memner Deng aesignea. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) IT 7" o/c Bottom Edge (Lu) 13' 7" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Snow Vertical Loads Location (Side) Tributary Width (0.90) (1.00) (1.15) Comments 0 - Self Weight (PLF) 1 1/4" to 13' 7 3/4" N/A 10.4 1 - Uniform (PLF) 0 to 13' 9" (Front) N/A 32.3 159.8 66.8 Linked from: Deck joists, Support 1 System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : Aso Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Todd Fisher Harriott Valentine Engineers (206) 624-4760 trisher@harriottvalentine.com 8/21/2020 9:13:55 PM UTC ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0 Weyerhaeuser File Name: Goodman Page 9 / 9 a F O " ' " CM SOLUTIONS REPORT PASSED Roof - vaulted ceiling, HEADER SUPPORTING KING POST AT WEST Current Solution: 2 piece(s) 4 x 8 Douglas Fir -Larch No. 1 Overall Length: 3' 0 0 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 4691 @ 2" 15313 (3.50") Passed (31%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 4680 @ 10 3/4" 7004 Passed (67%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 6241 @ 1' 6" 7640 Passed (82%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.011 @ 1' 6" 0.089 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.017 @ 1' 6" 0.133 Passed (L/999+) 1.0 D + 1.0 S (All Spans) All Product Solutions Depth Series Plies Wood Volume 7 1/4" 4 x Douglas Fir -Larch No. 1 2 86.28 System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD The purpose of this report is for product comparison only. Load and support information necessary for professional design review is not displayed here. Please print an individual Member Report for submittal purposes. ForteWEB Software Operator Job Notes Todd Fisher Harriott Valentine Engineers (206) 624-4760 trisher@harriottvalentine.com 8/21/2020 10:37:26 PM UTC ForteWEB v3.0, Engine: V8.1.3.1, Data: V8.0.0.0 Weyerhaeuser File Name: Goodman Page 1 / 1 U.S. Seismic Design Maps https://seismicmaps.org/ ¢�o 8010 181 st PI SW, Edmonds, WA 98026, USA Latitude, Longitude: 47.8343172,-122.342019 85t% Ir--stmentPoetry Go gle Date Design Code Reference Document Risk Category Site Class Type Value SS 1.306 S1 0.462 SMS 1.567 SM1 null -See Section 11.4.8 SDS 1.045 SD1 null -See Section 11.4.8 Type Value SDC null -See Section 11.4.8 Fa 1.2 Fv null -See Section 11.4.8 PGA 0.559 FPGA 1.2 PGAM 0.671 TL 6 SsRT 1.306 SsUH 1.441 SsD 2.676 S 1 RT 0.462 S1UH 0.517 S1D 1.139 PGAd 0.948 CRS 0.906 Moth PI SW OSHPD 5 182nd PI SW n (D a C Q m .c 7/13/2020, 5:01:58 PM ASCE7-16 II D - Default (See Section 11.4.3) Description MCER ground motion. (for 0.2 second period) MCER ground motion. (for 1.0s period) Site -modified spectral acceleration value Site -modified spectral acceleration value Numeric seismic design value at 0.2 second SA Numeric seismic design value at 1.0 second SA Description Seismic design category Site amplification factor at 0.2 second Site amplification factor at 1.0 second MCEG peak ground acceleration Site amplification factor at PGA Site modified peak ground acceleration Long -period transition period in seconds Probabilistic risk -targeted ground motion. (0.2 second) Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration Factored deterministic acceleration value. (0.2 second) Probabilistic risk -targeted ground motion. (1.0 second) Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration. Factored deterministic acceleration value. (1.0 second) Factored deterministic acceleration value. (Peak Ground Acceleration) Mapped value of the risk coefficient at short periods Map data 02020 1 of 3 2020-07-13, 17:02 S. Seismic Design Maps https:Hseismicmaps.org/ Type Value Description CR1 0.894 Mapped value of the risk coefficient at a period of 1 s 2 of 3 2020-07-13, 17:02 S. Seismic Design Maps https:Hseismicmaps.org/ DISCLAIMER While the information presented on this website is believed to be correct, SEAOC /OSHPD and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in this web application should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. SEAOC / OSHPD do not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the seismic data provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the search results of this website. 3 of 3 2020-07-13, 17:02 Harriott Valentine Engineers Inc. SEISMIC DESIGN ASCE 7-10 Equivalent Lateral Force Procedure Occupancy Category Seismic Design Category Importance Factor Site Class Ss S1 Fa Fv Ct x hn Sens = Fa*Ss Smi = Fv*S1 SIDS = (2/3)*Sms SD1 = (2/3)*Smi Period Ta = Ct*hn^x To Ts Sa R DO Cd Section 9.5.5 ok? Equivalent Lateral Force Procedure (section 12.8) Cs 11 Table 1-1 D Table 11.6-1 1.00 Table 11.5-1 D Table 20.3-1 130.60 %g (from USGS Seismic Hazard Ct 46.20 %g (from USGS Seismic Hazard Ct 1.00 Table 11.4-1 1.50 Table 11.4-2 0.02 Table 12.8-2 0.75 Table 12.8-2 8.00 feet (height to highest level) 1.3060 Eq.11.4-1 0.6930 Eq.11.4-2 0.8707 g Eq. 11.4-3 0.4620 g Eq. 11.4-4 0.0951 s Eq. 12.8-7 0.1061 s per section 11.4.5 0.5306 s per section 11.4.5 0.0817 g per section 11.4.5 1.25 Table 12.2-1 1.25 Table 12.2-1 1.25 Table 12.2-1 Yes Table 12.6-1 0.6965 Eq.12.8-2 Area of trellis roof = 291 ft^2 Weight of trellis roof = 7 psf Total 2037 lb Base shear V = 1418.8 lb East/west eq: Load to columns near ex. house = 595.91 lb 297.96 lb/col M = 2682 lb-ft/col Load to south columns = 397.275 lb 198.64 lb/col M = 1788 lb-ft/col North/south eq: Load to columns at west = 496.593 lb 248.3 lb/col M = 2235 lb-ft/col Load to columns at east = 496.593 248.3 lb/col M = 2235 lb-ft/col Use DFL #1 8x8 Mr = 4992 lb-ft 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel. 206-624-4760 1 fax 447-6971 2020-08-21 Page of Harriott Valentine Engineers Inc. arves, 2008 data) arves, 2008 data) 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel. 206-624-4760 1 fax 447-6971 2020-08-21 Page Harriott Valentine Engineers Inc. CONCRETE BEAM ANALYSIS Moment phiMn = phi [ Asfy ( d - Asfy / 1.7f'cb) fy = 60.00 ksi f'c = 2.50 ksi b = 30.00 in d = 21.00 in As = 0.59 in2 phi = 0.90 phiMn = 54.93 kft #4 @ 12"oc vert. min Shear phiVc = phi [ 2 (f'c ^ 1/2) bd f'c = 2.50 ksi b = 30.00 in d = 21.00 in phi = 0.85 phiVc = 53.55 k phiVs = phi Av fy d / s s = 6.00 in Av = 1.24 in2 phiVs = 221.34 k phiVn = phiVc + phiVs phiVn = 274.89 k Minimum flexural reinforcement (rho = 200/fy): As min = 2.10 in2 For structural slabs, temperature and shrinkage reinforcement shall be provided: ratio = 0.0020',Grade 40) b = 30.00 in cover = 1.00 in h = 4.00 in As min = 0.24 in2 ratio = 0.0018',Grade 60) b = 30.00 in cover = 1.50 in h = 8.00 in As min = 0.43 in2 A minimum area of shear reinforcement shall be provided where Vu exceeds 1/2 phiVc: 1/2 phiVc: 26.78 k Except for: 1. Slabs and footings. 2. Concrete joist construction (per 1908.11). 3. Beams with total depth not greater than 10", 2-1/2 x flange thickness, or 1/2 web width. Minimum shear reinforcement Av = 50 bw s / fy Av min = 0.15 in2 s=d/2= 10.50 in s=d/4= 5.25 in 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 2020-08-21 tel 206-624-4760 1 fax 447-6971 Page of Harriott Valentine Engineers Inc. FOOTING WITH COMBINED AXIAL AND FLEXURAL LOADS Wall 1 In -Plane Sizes and Loads: superstructure: frame 1,800lb footing: length 2.50 ft (along same axis as applied moment) width 2.50 ft (perpendicular to applied moment) depth 2.00 ft weight 1,813lb soil abv. 0 lb total R = 3,613 lb M = 2,682 Ibft e = 0.74 ft B/6 = 0.42 ft Bearing Pressures: Reaction is OUTSIDE kern. (Use these results) x = 0.51 ft fp = Fa = Stability: Mot = Mr = 1898 psf 2,000 psf 2,682 Ibft 2,709 Ibft (Do not use these results) fa = 578 psf fb = 1030 psf fp = 1608 psf Fa = 2,000 psf (using 0.6W, per ASD Load Combinations) (using 0.6D, per ASD Load Combinations) 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 2020-08-21 tel 206-624-4760 1 fax 447-6971 Page of