BLD2021-0252+Structural_Analysis_or_Calculations+2.12.2021_7.56.49_PM+2046815RECEIVED Feb 13 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT These Calculations for Permit #BLD2021-0252 are APPROVED by the City of Edmonds Building Department JOB # 21011 sAacvJ STRUCTURAL COMPUTATIONS FOR LEWIS RESIDENCE REMODEL 7019 LAKE BALLINGER WAY EDMONDS, WASHINGTON 981326 FEB 8, 2021 42 BY: SABCO CONSULTING ENGINEERS 11322 34T11. DRIVE S.E. EVERETT, WASHINGTON TEL, (425) 33B-0342 INC. JOB # 2101 1 DESIGN CRITERIA: CODE: WIND: SEISMIC: ROOF SNOW LOAD: - ROOF DEAD LOAD: -- FLOOR DEAD LOAD: 201 B IBC 1 10 MPH,(3 SEC. GUST) EXPOSURE"C" SEISMIC USE GROUP I SITE CLASS D 25 PSF 15 PSF 15 PSF INDEX TO CALCULATIONS: GENERAL:------------------ G 1 - G2 LATERAL:-------------------- L1 - L4 FRAMING: ------------------ 81 - B 4 SMM=7 -A% SQDCOo CONSULTONG 1 1322 34M. DRIVE S.E. EVERETT, WASHINGTON 98208 TEL (425)3380342 JOB: Lt lwffRest`OCNC'L Rr-auoz3t- CRQ SUBJECT: F(17ly}` GJ9?dL/i c DATE: PCb&jotj BY KYS JOBS: 710 f( SHEETS 11144 OW COo NSULTONG 1 1322 34TH. DRIVE S.E. EVERETT, WASHINGTON 98208 TEL (425) 338 0342 JOB: _LcmS 0 C5; aM.0� i- ONC. SUBJECr pf*2Z,'�- Yr4Z422-ft. DATE: f BY K//YS JOBS: �N 0y-1 SHEET# L-L /!- JA F soy ! I rt -- 4tw�' /Root / 6? v fiLz-�.sn� 5/c76,CL7 J27.7"T77A "Ar SABCD CONSUL76HO EMOMEERS ONC. 11322 34TH. DRIVE S.E. EVERETT, WASHINGTON 98206 TEL (425) 338 0342 JOB: 1-141AA SUBJECT: e-C4 M� I c- DATE:244,12v/ BY KYS JOB* SHEET # GF I SABCO CONSULTING ENGINEERS INC. Title: LEWIS RESIDENCE REMODEL Job # 21011 11322 34TH DRIVE BE Dagnr: KHALED SABRA,ME,PE Date: 2:12PM, 8 FEB 21 EVERETT, WASHINGTON 98208 Description : DESIGN MEETS THE 2018 IBC STANDARDS AND SPESIFICATIONS Scope: SCOPE OF WORK: ONE BEAM ONLY (31 , l Uw.M-0605oac,Vw5.8.0,t-De 2003 General Timber Beam Page 1 i (c)t9a3-2003 ENERCALC Engir dM Sa"re 6eam5.B�vcCalalelion5 Description GL OPTION BEAM BETWEEN KITCHEN DINING AND LIVING [General information . Base allowabies are user defined Section Name 6.125x12 Center Span 18.50 ft .....Lu 0.00 ft Beam Width 5.125 in Left Cantilever ft .....Lu 0.00 It Beam Depth 12.000 in Right Cantilever It .....Lu 0.00 ft Member Type Glul-am 24F-V4 Fb Base Allow 2,400.0 psi Load Dur. Factor 1.150 Fv Allow 240.0 psi Beam End Fixity Pin -Pin Fc Allow 650.0 psi E 1,800.0 ksi Center DL 165.00 #/it LL 275.00 #A Left Cantilever DL #/ft LL #/ft Right Cantilever DL #/ft LL #M Beam Design OK Span= 18.50ft, Beam Width = 5.125in x Depth = 12.in, Ends are Pin -Pin Max Stress Ratio 0,665 : 1 Maximum Moment 18.8 k-ft Maximum Shear * 1.5 6.1 k Allowable 28.3 k-ft Allowable 17.0 k Max. Positive Moment 18.82 k-ft at 9.250 ft Shear: @ Left 4.07 k Max. Negative Moment 0.00 k-ft at 0.000 ft @ Right 4.07 k Max @ Left Support 0.00 k-ft Camber: @ Left 0.000 in Max @ Right Support 0.00 k-ft @ Center 0.491 in Max. M allow 2829 Reactions... @ Right 0.000in fb 1,836.46 psi fv 99.27 psi Left DL 1.53 k Max 4.07 k Fb 2,760.00 psi Fv 276.00 psi Right DL 1.53 k Max 4.07 k Deflections Deflection -0.327 in ...Location 9.250 ft ...Length/Deft 678.2 Camber ( using 1.6 * D.L. Deft I ... @ Center 0.491 in @ Left 0.000 in @ Right 0.000 in 9.250 It 254.31 Deflection ...Length/Deft Right Cantilever... Deflection ...Length/Deft 0.000 in 0.000 in 0.0 0.0 0.000 in 0.000 in 0.0 0.0 SABCO CONSULTING ENGINEERS INC. Title: LEWIS RESIDENCE REMODEL Job # 21011 11322 34TH DRIVE SE Dsgnr: KHALED SABRA,ME,PE Date: 2:12PM, 8 FEB 21 EVERETT, WASHINGTON 98208 DescriPbon : DESIGN MEETS THE 2018 IBC STANDARDS AND SPESIFICATIONS �a2 Scope : SCOPE OF WORK: ONE BEAM ONLY `l General Timber Beam KITCHEN SABCO CONSULTING ENGINEERS INC. 11322 34TH DRIVE SE EVERETT, WASHINGTON 98208 Tide: LEWIS RESIDENCE REMODEL Job#21011 Dsgnr: KHALED SABRA,ME,PE Date: 2:12PM, 8 FEB 21 D"CdPdOn : DESIGN MEETS THE 20181BC STANDARDS AND SPESIFICATIONS Scope: SCOPE OF WORK: ONE BEAM ONLY i u�cwoaoaevs.a ._._ General Timber Beam Description PSL OPTION BEAM BETWEEN KITCHEN General Information Base allowables are user defined Section Name Prllm: 5.25x11.875 Center Span 18.50 ft .....Lu 0.00 ft Beam Width 5.250 in Left Cantilever it .....Lu 0.00 ft Beam Depth 11.875 in Right Cantilever ft .....Lu 0.00 ft Member Type GluLam PSL (2.OE) Fb Base Allow 2,900.0 psi Load our. Factor 1.150 Fv Allow 290.0 psi Beam End Fixity Pin -Pin Fc Allow 750.0 psi E 2,000.0 ksi Full Length Uniform Loads -- Center DL 165.00 Wft LL 275.00 #7ft Left Cantilever OL #/ft LL #/ft Right Cantilever DL #/ft LL #/ft Beam Design OK Span= 18.5011, Beam Width = 5.250in x Depth = 11,875in, Ends are Pin -Pin Max Stress Ratio 0.549 : 1 Maximum Moment 18.8 k-ft Maximum Shear 1.5 6.1 k Allowable 34.3 k-ft Allowable 20.8 k Max. Positive Moment 18.82 k-ft at 9.250 It Shear: @ Left 4.07 k Max. Negative Moment 0.00 k-ft at 0.000 It @ Right 4.07 k Max @ Left Support 0.00 k-ft Camber: @ Left 0.000 in Max @ Right Support 0.00 k-ft @ Center 0.445 in Max. M allow 34.29 Reactions... @ Right 0.000 in It, 1,830.68 psi fv 97.92 psi Left DL 1.53 k Max 4.07 k Fb 3,335.00 psi Fv 333.50 psi Right DL 1.53 k Max 4.07 k Deflections 1 Deflection -0.297 in -0.791 in Deflection 0.000 in 0.000 in ...Location 9.250 ft 9.250 ft ...Length/Deft 0.0 0.0 ...Length/Deft 748.0 280.51 Right Cantilever... Camber ( using 1.5' D.L. Defl ) ... Deflection 0.000 in 0.000 in @ Center 0.445 in ...Length/Defl 0.0 0.0 @ Left 0.000 in @ Right 0.000 in SABCO CONSULTING ENGINEERS INC. Title: LEWIS RESIDENCE REMODEL Job 821011 11322 34TH DRIVE SE Dagnr: KHALED SABRA,ME,PE Date: 2:12PM, 8 FES 21 EVERETT, WASHINGTON 98208 D"Crlpnon: DESIGN MEETS THE 201816C STANDARDS AND SPESIFICATIONS J Scope: SCOPE OF WORK: ONE BEAM ONLY `� Rev: 5W= USN: KW-0605036, Va6.e.0, 1-De-= General Timber Beam Page 2 (c)1883-2003 ENERCALC Eng:,nmdng Software beams.ec .Catalan" Description PSL OPTION BEAM BETWEEN KITCHEN DINING AND LIVING