Loading...
APPROVED BLD BLD2021-0353+Architectural_Plan+3.9.2021_2.41.04_PM+2083680EXISTING RESIDENCE (E) LEDGER TO REMAINS D I \—NEW 51MP50N "DTT I Z" ANCHORS > VERIFY (E) OR PROVIDE NEW (TOTAL OF 5 AT NEW DECK) 51MP50N "LU528Z" HANGERS AT LEDGER O ' ___+7::EX15TING DECK JOISTS TO REMAIN - NO CHANGE o I 1 OII G1 _ Gil GI G11 GI G11 GI Gil I 1 OII of v 2 3 _ DI DI KB KB KB KB KB KB - - - - - - J L- NEW PT Gx 10 hF#2 BEAM N KNEE BRACES AT POSTS O TOTAL OF (G) AT DECK NEW PT 4xG POSTS, (V w/ 24"x24" FOUNDATIONS TOTAL OF (5) AT DECK EXISTING WOOD GUARDRAILING TO REMAIN - NO CHANGE _2'-0" 8'-O" _2'-0" _ 14'-0" _2'-011 EX15TING 51DE DECK JOISTS TO REMAIN, EX15TING BEAM WITH POSTS TO BE REPLACED. TEMPORARY SHORING OF THE JOISTS WILL BE NECESSARY PRIOR TO REMOVING THE EXISTING BEAM AND INSTALLING NEW BEAM. ALL SHORING WORK AND INSTALLATION SHALL BE PER THE CONTRACTOR 5/4"xG" COMPOSITE DECKING TO BE INSTALLED, SPACE DECKING MIN 1/4" APART TO ALLOW DRAINAGE (OR PER MFR. RECOMMENDATIONS) SIDE DECK FLAMING / FOUNDATION PLAN 1/4 11 _ 1 I-011 TYPICAL DECK FRAMING NOTES: ALL WORK TO CONFORM TO CURRENT BUILDING CODE: IRC-2018 TYPICAL SOIL BEARING CAPACITY = 1 500 P5F (ASSUMED). CONTRACTOR TO INSTALL FOOTINGS ON FIRM NATIVE SOIL OR THOROUGHLY COMPACTED STRUCTURAL FILL AS REQ'D. ALL FRAMING MEMBERS TO BE *PRESSURE TREATED* HEM -FIR #2 OR BETTER UNLESS NOTED OTERWI5E ON PLANS. NEW 30" HIGH GUARDR w/ TOP -MOUNTED PC AT PORCH AND STAIRS PERIMI NEW PT 4xG hF#2 LANDING BE w/ PT 4x4 H F#2 PC 1 2" DIAM. 50NOTUDE FOl NEW PT 2x8 HF#2 @ 1 LANDING JO O N .._._._._._._._._._._.� Hardware and fasteners in contact with ■ ' preservative -treated wood shall be of hot -dipped zinc galvanized steel, ■ stainless steel, silicon bronze or copper. In the absence of manufacturer's ■ recommendations a minimum of ASTM A 653 type G185 zinc -coated galvanized steel, or ■ equivalent, shall be used. I IRC R317.3.1 IBC 2304.10.5.1 ■ EXISTING WOOD GUARDRAILING TO REMAIN - NO CHANGE NEW BEAM PER NEW POSTS PER O ALL POSTS TO BE GxG *PRESSURE TREATED* HEM -FIR #2 UNLESS NOTED OTHERWISE FASTENER NOTES: IRC 319.3 FASTENERS FOR PRESSURE TREATED PRESERVATIVE AND FIRE RETARDANT TREATED WOOD SHALL BE HOT DIPPED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER ALL STRUCTURAL CONNECTOR HARDWARE SHALL BE Z-MAX COATED "51MP50N STRONG -TIE" OR APPROVED EQUIVALENT. "LEDGER-LOK" SCREWS * "THRU-LOK" BOLTS SHALL BE INSTALLED PER MANUFACTURER'S TECHNICAL 5ULETIN5 AND ICC E5R REPORT # 1 078. ENGINEERING NOTE: PLANS * DETAILS SHOWN HAVE BEEN DESIGNED * ENGINEERED FOR THIS SPECIFIC PROJECT. CONTACTOR SHALL CONTACT ENGINEER IF SITE CONDITIONS DIFFER OR SUBSTITUTIONS ARE REQUESTED. ALL WORK SHALL BE INSPECTED BY BUILDING OFFICIAL. PT HF#2 LEDGER "LEDGER-LOK' SCREWS 2 PER BAY FOR I G"oc JOISTS) ?x8 HF#2 @ I G"oc DISTS IxG HF#2 BEAM GZ" HANGER AT RIM BOARD Ex4 POST AM. 50NOTU13E FOUND. POST TO REMAIN :TOR TO COORDINATE STAIR FRAMING IRS 2 @ 1 2"oc STRINGERS 0 EXISTING FRONT PORCH TO BE REMOVED AND DISPOSED, NEW FRONT WITH STAIRS TO BE CONSTRUCTED 5/4"xG" COMPOSITE DECKING TO BE INSTALLED, SPACE DECKING MIN 1/4" APART TO ALLOW DRAINAGE (OR PER MFR. RECOMMENDATIONS) FRONT PORCH FOUNDATION / FRAMING PLAN 1/4 11 = 1 1-011 EXISTING RESIDENCE - III III III III III I —NEW P05T FOUNDATIONS PER PLAN I SIDE DECK RIGHT E 3/1 611 _ I 1-011 (E) ROOF POST TO REMAI NEW PERIMETER 3G" HIGH GUARDRAILS w/ TOP -MOUNTED POSTS LEVATION (E) PT DECK JOISTS TO REMAIN PT 2x BLOCKING AT BEAM BETWEEN DECK JOISTS NEW PT BEAM PER 51MP50N "PCGZ" POST CAP z I C7 w C� w NEW PT POST PER PLAN ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE �EXISTING WOOD GUARDRAILING TO REMAIN - NO CHANGE EXISTING RESIDENCE KNEE BRACES PER PLAN NEW BEAM PER PLAN NEW POSTS PER PLAN III III III III III III NEW P05T FOUNDATIONS PER PLAN —III I SI DE DECK FRONT ELEVATION 3/1 611 = I 1-011 EXISTING RE51C DECKING PLANKS PER PLAN 5IMP5ON "A5U4GZ" POST BASE w/ 5/8" DIA x5" EMBED PT POST PER PLAN SS -WEDGE ANCHOR \ \ \ I O" DIAM. CONCRETE PLINTH. CUT EXISTING CONC. SLAB DOWEL INTO FOOTING •o TO ACCOMODATE NEW POST FOOTING o w/ (4)#4 VERT BARS u —1 I II I II I— _z CONCRETE FOOTING CID PER PLAN - O NEW PT 4x4 HF#2 KNEE BRACE 1 /2"xG" GALV. LAG SCREW w/ PL WASHER EMBED 3-1/2" MIN INTO POST AND COUNTERSINK TO KNEE -BRACE DECK FLAMING / KNEE GLACE DETAIL 2 3/411 _ 1 I-011 EXISTING RESIDENCE ROOF P05T TO REMAIN NEW POSTS PER PLAN a 7T�EW POST SONOTUBE - FOUNDATIONS PER PLAN— II I II I II I II I II I I I I I I I I I I II I I� FRONT PORCH SIDE ELEVATION 3/1 611 = 1 1-011 MIN PT (8)# 1 EACH END )#4 BARS EA. WAY 51ZE PER PLAN SIDE DECK NEW FOUNDATION DETAIL 3 3/411 _ 1 I-011 5"x5"x3/8" MOUNTING PLATE 2x8 MIN RIM JOIST45IMP50N (4)-3/8"0 GALV OR SS LAG SCREW PRE -DRILLED WITH 114" PILOT HOLES AND SOAP TH READ5 4x8 (MIN) FULL HEIGHT BLOCKING BETWEEN JOISTS "LU528" B OR EQUIV. SECTION A -A ALUMINUM POST DECKING SECTION B-B MOUNTING BRACKET BY OTHERS NG BEYOND GUARDRAIL POST ATTACHMENT DETAIL 3/411 = 1 1-011 APPROVED PLANS MUST BE ON JOB SITE =DGER TO REMAIN :XISTING LEDGER SCREWS PER CODE EW DECKING PLANKS PER PLAN XISTING DECK JOISTS TO REMAIN EW 51MP50N "DTT I Z" ANCHORS Elf PLAN FOR LOCATIONS IMP5ON "5DHW" TIMBER SCREW, MBED 3" TO HOU5E WALL TOP PLATE OR 2x WALL STUD LEDGER CONNECTION DETAIL 3/411 — I 1-011 PT POST PER PLAN DIAM. PER PLAN 5IMP50N "A5U44Z" POST BASE w/ 5/8" DIA x5" EMBED 55-WEDGE ANCHOR _z CID CONC. 50NOTU13E FOUNDATION w/ (4)#4 VERT BARS ON BE FOUND. DETAIL 4 3/411 = 11-011 51MP50N "15CZ" STRINGER CONNECTORS FASTEN STAIR BACKING PLATE TO'j DECK RIM JOIST w/ 51MP50N "TJC37" FLAT PLATE BTWN EACH STRINGER (MIN 2) STAIR NOTES: HANDRAILS ON STEPS TO HAVE ENDS RETURNED AND PLACED MIN. 34", MAX. 38" ABOVE STEP NOSING. THE HAND GRIP PORTION OF HANDRAIL SHALL NOT BE LESS THAN 1 -1 /2" NOR MORE THAN 2" IN CROSS -SECTIONAL DIMENSION OR THE 5hA SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE. THE HANDGRIP PORTION OF HANDRAILS SHALL HAVE A SMOOTH 5URFAC WITH NO SHARP CORNERS. RAILING SHALL NOT PA55 A 4" 5PhERE. THERE SHALL BE N( MORE THAN A 3/8" VARIANCE BETWEEN THE TALLEST RISER AND THE 5hORTE5T RISER 0 ANY FLIGHT OF STEPS. I.V IV I. ✓ILI I I'\V VI\ DECK BELOW STAI L 1=LAMING DETAIL RECEIVED 6 3/411 = I ar 10 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z WOUj Uj 0 x W U > Z i 0 0 I: mip (255) 265-4522 inquiry@evergreen horn eexteriors.com Z O Lu v y LU kD w LU p J m Q W Q Q m I.0 m Q Z 3 / 512021 V J W 0 } r-6 U (13 co `n � r- Q 0 lIl W N Q � w O^/ L.� DATE: 3/(5/202 I SHEET SIZE: 24" x 36" DRAWING: D 1 BLD2021-0353