APPROVED BLD BLD2021-0858+Architectural_Plan+6.18.2021_3.00.07_PM+2259031S H K S A R C H I T E C T S ABBREVIATIONS DRAFTING SYMBOLS & AND GA GAUGE R or RAD RADIUS L ANGLE GALV GALVANIZED RB RESILIENT BASE SIM @ AT GB GRAB BAR RCP REFLECTED CEILING PLAN 1 WALL SECTION 0 DIAMETER GC GENERAL CONTRACTOR RD ROOF DRAIN A101 # POUND OR NUMBER GL GLASS REF REFERENCE (E) EXISTING GLB GLU-LAM BEAM REFR REFRIGERATOR i CENTERLINE GND GROUND REINF REINFORCED SIM R PROPERTY LINE GR GRADE RELOC RELOCATE 1 BLDG SECTION GRT'D GROUTED REQ'D REQUIRED A101 A.B. ANCHOR BOLT GWB GYPSUM WALL BOARD RES RESILIENT ABV ABOVE RM ROOM AC AIR CONDITIONING HB HOSE BIBB RO ROUGH OPENING 1 ACP ACOUSTIC CEILING PANEL HC HANDICAP RV ROOF VENT ACU AIR CONDITION UNIT HCMU HOLLOW CLAY MASONRY UNIT RL RAIN WATER LEADER ADJ ADJUSTABLE HDWD HARDWOOD 1 A101 1 EXTERIOR ELEVATION AFF ABOVE FINISHED FLOOR HOWE HARDWARE S SOUTH ALT ALTERNATE HT HEIGHT SA SMOKE ALARM ALUM ALUMINUM HM HOLLOW METAL SC SOLID CORE 1 APPROX APPROXIMATELY HR HOUR SCHED SCHEDULE ARCH ARCHITECT, ARCHITECTURAL HORIZ HORIZONTAL SECT SECTION 1 SG SAFETY GLASS BLDG BUILDING I.D. INSIDE DIAMETER SHT SHEET 1 A101 1 INTERIOR ELEVATION BLW BELOW INSUL INSULATION SIM SIMILAR BM BEAM INT INTERIOR SPEC SPECIFICATION SQ SQUARE 1 B.O. BOTTOM OF S.S. STAINLESS STEEL BRS BACKER ROD & SEALANT JAN JANITOR STA STATION JT JOINT STD STANDARD SIM CB CATCH BASIN 1 DETAIL CBB CEMENT BACKER BOARD STL STEEL KIT KITCHEN STN STAIN A101 CEM CEMENT STOR STORAGE CJ CONTROL JOINT LAB LABORATORY STRUCT STRUCTURE CL CENTERLINE LAM LAMINATE SOG SLAB ON GRADE CLG CEILING LAV LAVATORY SUSP SUSPENDED CLR CLEAR LKR LOCKER SYM SYMMETRICAL NORTH ARROW CO CLEAN OUT LOC LOCATE COL COLUMN CONIC CONCRETE LT LIGHT T, TMP TEMPERED LVL LAMINATED VENEER LUMBER COND CONDITION T&G TONGUE &GROOVE CONT CONTINUOUS M MEN'S TEL TELEPHONE GRID HEAD CPT CARPET TER TERRAllO CT CERAMIC TILE MAIL MATERIAL THK THICK MAX MAXIMUM CTR CENTER T.O. TOP OF ROOM NAME MC MEDICINE CABINET ROOM TAG MECH MECHANICAL TS TUBE STEEL 101 DBL DOUBLE MEMB MEMBRANE TV TELEVISION DEMO DEMOLISH MFR MANUFACTURER TYP TYPICAL WINDOW & OF DRINKING FOUNTAIN MIN MINIMUM 1i STOREFRONT TAG DIA DIAMETER MIR MIRROR UL UNDERWRITERS' LABORATORIES DIFF DIFFUSER MISC MISCELLANEOUS UNO UNLESS NOTED OTHERWISE DIM DIMENSION MH MANHOLE UTIL UTILITY R1 FLOOR, WALL, OR DISP DISPENSER MO MASONRY OPENING ROOF TAG ON DOWN MTD MOUNTED VCT VINYL COMPOSITION TILE DR DOOR MTL METAL VERT VERTICAL <6> CASEWORK TAG DS DOWNSPOUT MULL MULLION VEST VESTIBULE DTL DETAIL VIF VERIFY IN FIELD DW DISHWASHER N NORTH VTR VENT THRU ROOF 101 DOOR TAG NA NOT APPLICABLE E EAST NIC NOT IN CONTRACT W WEST EA EACH NOM NOMINAL W/ WITH ECS EXTERIOR COMPOSITE SIDING NITS NOT TO SCALE WC WATER CLOSET EF EXHAUST FAN NR NOT RATED WD WOOD 1 KEY NOTE EJ EXPANSION JOINT WF WIDE FLANGE EL ELEVATION ELEC ELECTRICAL OA OVERALL W/0 WITHOUT NAME ELEV ELEVATOR OBS OBSCURE ELEVATION ELEVATION NOTE O.C. ON CENTER WOM WALK OFF MAT EMERG EMERGENCY O.D. OUTSIDE DIAMETER WM WOMEN'S EQ EQUAL OFF OFFICE WP WATERPROOFING EXP EXPANSION OPNG OPENING WR WATER RESISTANT XXX SPOT ELEVATION T.O. XXX OPP OPPOSITE WSCT WAINSCOT FBP FIBER BOARD PANEL WT WEIGHT FD FLOOR DRAIN PC PRECAST CONCRETE FE FIRE EXTINGUISHER PL PLATE CENTERLINE FF FINISH FLOOR PLAS PLASTER FH FIRE HYDRANT PLY PLYWOOD FIN FINISH P.LAM PLASTIC LAMINATE FLR FLOOR PNT PAINT - R - PROPERTY LINE F.O. FACE OF POC POINT OF CONNECTION FDIC FURNISHED BY OWNER, PR PAIR XXx,XXX FLOOR TRANSITION INSTALL BY CONTRACTOR PSL PARALLEL STRAND LUMBER F010 FURNISHED BY OWNER PT PRESSURE TREATED INSTALL BY OWNER PTN PARTITION FIR FIRE RESISTANT Al REVISION FS FLOOR SINK DESCRIPTION FT FEET QT QUARRY TILE BREAKLINE DIMENSION POINT MATERIAL SYMBOLS ENLARGED DETAIL CALLOUT BATT INSULATION CONCRETE RIGID INSULATION SIM _ 1 A101 EARTH GRAVEL WOOD MASONRY PLYWOOD STEEL GENERAL NOTES 1. MATERIALS, ASSEMBLIES AND NOTED ITEMS ARE NEW UNLESS OTHERWISE NOTED. 2. CONTRACTOR SHALL VERIFY CONDITIONS. NOTIFY THE ARCHITECT OF ANY CONDITIONS INCONSISTENT WITH THE INTENT OF THE DRAWINGS PRIOR TO STARTING OR CONTINUING WORK IN THE AREA CONCERNED. CODE: 1. ALL WORK SHALL CONFORM TO APPLICABLE CODES AND LOCAL BUILDING REQUIREMENTS, WHICH INCLUDE THE MOST CURRENT EDITIONS OF THE INTERNATIONAL BUILDING CODE WITH LOCAL AMENDMENTS, INTERNATIONAL MECHANICAL CODE (IMC), NATIONAL ELECTRICAL CODE (NEC), INTERNATIONAL FIRE CODE (IFC), AND WASHINGTON STATE ENERGY CODE (WEC). 2. REFER TO WINDOW SCHEDULE FOR WINDOW SIZES AND TYPES. ALL GLAZING WITHIN 18" OF INTERIOR FLOOR, EXTERIOR WALKING SURFACE OR WITHIN 24" OF A DOOR IN ANY POSITION TO BE TEMPERED GLASS UNLESS INDICATED OTHERWISE. 3. MECHANICAL, ELECTRICAL AND PLUMBING PERMITS TO BE APPLIED FOR UNDER SEPARATE APPLICATION BY CONTRACTOR. 4. PROVIDE FIREBLOCKS AND DRAFTSTOPS PER IBC. DEMOLITION: 1. WHERE ITEMS ARE INDICATED ON PLANS TO BE DEMOLISHED, IT SHALL MEAN THE COMPLETE REMOVAL AND DISPOSAL OF THE ITEM INDICATED UNLESS OTHERWISE NOTED. CONTRACTOR IS RESPONSIBLE FOR REVIEW OF THE HAZARDOUS MATERIALS ABATEMENT, ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR CUTTING AND PATCHING WORK. DIMENSIONS: 1. DO NOT SCALE DRAWINGS. 2. VERIFY DIMENSIONS SHOWN ON DRAWINGS. USE ONLY DIMENSIONS INDICATED. PRIOR TO STARTING OR CONTINUING WORK, NOTIFY ARCHITECT OF DISCREPANCIES OR CONDITIONS INCONSISTENT WITH THE INTENT OF THE CONSTRUCTION DOCUMENTS. 3. DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF MASONRY, OR FACE OF STUD, UNLESS OTHERWISE NOTED. 4. FINISHED SURFACE OF INFILL OR EXTENSIONS OF EXISTING PARTITIONS SHALL ALIGN WITH ADJACENT EXISTING SURFACES UNLESS OTHERWISE NOTED. 5. VERTICAL DIMENSIONS ARE MEASURED FROM STRUCTURAL SLAB, TOP OF STEEL OR TOP OF SHEATHING, UNLESS NOTED OTHERWISE. 6. DOORS NOT LOCATED BY DIMENSION ON PLANS SHALL BE SIX INCHES FROM FACE OF ADJOINING PARTITION TO HINGE EDGE OF DOOR OPENING. PROVIDE MINIMUM 18" CLEAR FROM FACE OF ADJOINING PARTITION OR OTHER OBSTRUCTION TO JAMB EDGE OF DOOR OPENING, UNLESS OTHERWISE NOTED. NOTIFY ARCHITECT IF REQUIRED CLEARANCES ARE NOT AVAILABLE. COORDINATION: 1. COORDINATE ALL OPERATIONS WITH OWNER, SUCH AS AREAS USED FOR MATERIAL STORAGE, ACCESS TO AND FROM THE SITE, TIMING OF WORK AND REQUIREMENTS OF NOISE ORDINANCE. INSTALL DUST AND NOISE BARRIERS AS REQUIRED TO PROTECT EXISTING ADJACENT BUILDINGS AND OCCUPANTS AND TO MAINTAIN AN ENVIRONMENT SUITABLE TO PERMIT CONTINUED OCCUPANCY OF SUBJECT AND ADJACENT BUILDINGS. 2. REVIEW DEMOLITION DRAWINGS. PATCH AND REPAIR ALL EXISTING SURFACES AFFECTED BY DEMOLITION WORK. 3. VERIFY LOCATIONS OF EXISTING UTILITIES. CAP, MARK AND PROTECT AS NECESSARY TO COMPLETE THE WORK. 4. REVIEW ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS AND PROVIDE ROUGH -INS THROUGH SLABS, BEAMS, WALLS, CEILINGS, AND ROOFS FOR DUCTS, PIPES, CONDUITS, JUNCTION BOXES, CABINETS AND EQUIPMENT. VERIFY SIZE AND LOCATION BEFORE PROCEEDING WITH WORK. COORDINATE WITH INSTALLATION REQUIREMENTS. PATCH AND REPAIR EXISTING SURFACES AS NECESSARY TO COMPLETE WORK. 5. COORDINATE AND PROVIDE REQUIRED PENETRATIONS AND PATCHING WITH INDIVIDUAL SUBCONTRACTORS TO SUIT NEW WORK. 6. CONTRACTOR TO OBTAIN AND VERIFY ROUGH -IN DIMENSION REQUIREMENTS FOR CABINETRY, EQUIPMENT, ACCESSORIES AND THE LIKE INCLUDING THOSE DESIGNATED FDIC AND FOIO. CONTRACTOR TO PROVIDE BACKING, BLOCKING, SUPPORT AS REQUIRED FOR INSTALLATION. CONTRACTOR TO COORDINATE POWER, DATA, COMMUNICATIONS AND SECURITY REQUIREMENTS FOR FOIC AND FOIO EQUIPMENT WHERE SERVICES ARE REQUIRED. INCLUDE STUB OUTS AND CONNECTIONS. VERIFY AND COORDINATE DIMENSIONS OF FDIC AND FOIO ITEMS PRIOR TO PROCEEDING WITH WORK. INCLUDE STUB OUTS FOR FUTURE WORK. 7. PIPING, CONDUITS, DUCTS, ETC. SHALL BE CONCEALED IN WALLS, CHASES, ABOVE SUSPENDED CEILINGS, BELOW FLOORS OR BE FURRED -IN IN ROOMS WITH EXISTING CEILINGS, UNLESS OTHERWISE NOTED. DO NOT CONCEAL PIPING, CONDUITS, DUCTS, ETC. IN ELECTRICAL, MECHANICAL, AND COMMUNICATION ROOMS. 8. CAREFULLY COORDINATE MECHANICAL, ELECTRICAL, AND BUILDING SYSTEM INSTALLATIONS WITH EXISTING STRUCTURE AND BUILDING SYSTEMS. 9. "REMOVE" MEANS TO COMPLETELY AND PERMANENTLY REMOVE FROM THE PROJECT. ENERGY CODE ANALYSIS 2018 WASHINGTON STATE ENERGY CODE (TABLE R402.1.1, CLIMATE ZONE, 4C - KING) FENESTRATION U-FACTOR U-0.30 SKYLIGHT U-FACTOR U-0.50 GLAZED FENESTRATION SHGC NR CEILING R-49 WOOD FRAME WALL R-21 INT BELOW -GRADE WALL R-10/15/21 INT. SLAB R-10, DEPTH 2 ft PROJECT INFORMATION PROJECT OWNER: JOSHUA AND IHLAE ROSEN 21507 88th AVE W EDMONDS, WA 98026-7311 PROJECT ADDRESS: 21507 88th AVE W EDMONDS, WA 98026-7311 SCOPE DESCRIPTION: -DEMOLITION OF PORTION OF NON- STRUCTURAL PARTITION WALLS -NEW KITCHEN CASEWORK, APPLIANCES, FINISHES, LIGHTING. -NEW WINDOWS AND SKYLIGHTS ZONING ANALYSIS ZONE: RS-8 CURRENT USE: SINGLE-FAMILY RESIDENCE YEAR BUILT: 1983 LOT AREA: 7740 SF LEGAL DESCRIPTION: LAURI ANN PARK NO. 4 BLK 000 D-00 - LOT 4 (E) BUILDING AREA: 1 ST FLOOR: 1637 SF 2ND FLOOR: 1637 SF TOTAL: 3274 SF PROPOSED BUILDING AREA NO CHANGE PROPOSED LOT COVERAGE: NO CHANGE FAR: NO CHANGE PARKING: NO CHANGE REQUIRED SETBACKS: FRONT SETBACK: 25'-0" SIDE SETBACK: 716" REAR SETBACK: 15'-0" HEIGHT LIMIT: NO CHANGE DESIGN TEAM ARCHITECT: SHKS ARCHITECTS 1050 NORTH 38TH ST SEATTLE, WA 98103 TEL: 206.675.9151 CONTACT: Andreas Baatz EMAIL: andreasb@shksarchitects.com STRUCTURAL ENGINEER: SSF ENGINEERING 1201 1 ST AVE S #310 SEATTLE, WA 98134 TEL: 206.956.3722 CONTACT: Ryan Anderson EMAIL: rnderson@ssfengineers.com APPLICABLE CODES 2018 INTERNATIONAL RESIDENTIAL CODE 2018 UNIFORM PLUMBING CODE 2018 INTERNATIONAL FIRE CODE 2018 WASHINGTON STATE ENERGY CODE - RESIDENTIAL SHEET INDEX A0.0 COVER SHEET A1.0 SITE PLAN A3.0 EXTERIOR ELEVATIONS A2.1.1 DEMO AND FLOOR PLANS A3.1 BUILDING SECTIONS AND ELEVATIONS XA3.0 EXTERIOR ELEVATIONS XAD2.0 DEMO PLAN LIA?Ai1:1d1&I10110111Wd101 OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE City Of Edmonds Building Department Work KITCHEN REMODEL Address 21507 88TH AVE W Owner ROSEN Approved Date 7/6/2021 Building Official W. X VfAALIL Permit Number BLD2021-0858 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com 5158 REGISTERED ARC ITECT JONATHAN H. HA U G STATF OF WASHI GTO JOSHUA & IHLAE ROSEN ROSEN KITCHEN REMODEL PERMIT SET 21507 88TH AVE W EDMONDS, WA 98026 Drawn by: AB Checked: JH Date: 06/18/2021 Scale: As indicated Revisions: No. Date Remarks o _ RECEIVED _ Jun 21 2021 CITY OF EDMONDS M - DEVELOPMENT SERVICES li DEPARTMENT H _ Z - CD "- COVER SHEET OG _ CD U - IIAOOO - O Z - o_ CV V CV (V O N co 1 ST FLOOR PLAN ORESIDENCE PLAN 1 q1/8 PLAN 1'-0" 20'-0" REQUIRED FRONT YARD SETBACK - (E) 12" DIA TREE (E) LANDSCAPING, TYP (E) 6" CONIC CURB (E) 6" WD STAIR W a co (E) CURB CUT (E) 6" CONIC CURB CM (E) LIVING ROOM (E) PRIMARY D ENTRY (E) ENTRY/HALL (E) STAIR (E) DINING ON KITCHEN (E) BEDROOM (E) BATH (E) BATH 2ND FLOOR PLAN (E) BEDROOM (E) BEDROOM (E) WD FENCE R 82.02' / I (E) CHIMNEY / 25' - 0" +/ \ M \ 17 I I 1 PRIMARY ENTRY III PROJECT INFORMATION PROJECT OWNER: JOSHUA AND IHLAE ROSEN 21507 88th AVE W EDMONDS, WA 98026-7311 PROJECT ADDRESS: 21507 88th AVE W EDMONDS, WA 98026-7311 SCOPE DESCRIPTION: -DEMOLITION OF PORTION OF NON- STRUCTURAL PARTITION WALLS -NEW KITCHEN CASEWORK, APPLIANCES, FINISHES, LIGHTING. -NEW WINDOWS AND SKYLIGHTS REQUIRED SIDE YARD SETBACK (E) WD GATE ZONING ANALYSIS ZONE: RS-8 CURRENT USE: SINGLE-FAMILY RESIDENCE YEAR BUILT: 1983 LOT AREA: 7740 SF LEGAL DESCRIPTION: LAURI ANN PARK NO. 4 BILK 000 D-00 - LOT 4 (E) BUILDING AREA: 1 ST FLOOR: 1637 SF 2ND FLOOR: 1637 SF TOTAL: 3274 SF PROPOSED BUILDING AREA NO CHANGE PROPOSED LOT COVERAGE: NO CHANGE FAR: NO CHANGE PARKING: NO CHANGE REQUIRED SETBACKS: FRONT SETBACK: 25'-0" SIDE SETBACK: 716" REAR SETBACK: 15'-0" HEIGHT LIMIT: NO CHANGE I (E) CONC PAVERS ; I 2'-0"TYP I I (E) EAVE I I I (E) BUILDING FOOTPRINT I I I \ (E) LAWN 7 — I (E) RESIDENCE 1 1 , \ / _ / 21507 88TH AVE W i (E) CONCRETE DRIVEWAY PE) ELEC TO OWER POLE AREA OF WORK (INTERIOR ONLY) I EDMONDS, WA 98026-7311 I I PARCEL#: 1 19' - 10 3/41, +/- 00723500000400 I 150" PROPOSE SKYLIGHT I I I I I I I I I + I - (E) SECOND r FLOOR BALCONY ti (E) LAWN cc / (E) BALCONY POST, TYP I I I I I L------------------------ — 11iIi11 I LANDSCAPING (E) DRIVEWAY R 82.99' D I I I I I I I � (E) LAWN I I I I S I I I I 1 I I I I I I I I I I I I 0 I I I (ZE) EARTH/LANDSCAPING I I I I I I --------------J REQUIRED SIDE YARD SETBACK CM 0 1' 2' 4' 8' 10, REQUIRED REAR YARD SETBACK (E) WD FENCE (E) LANDSCAPING, TYP (E) WD SHED S H K S A R C H I T E C T S 1050 N.38th St. Seattle, WA 98103 — PH:206.675.9151 — www.shksarchitects.com FSTATF' RED ECT U G TO JOSHUA & IHLAE ROSEN ROSEN KITCHEN REMODEL PERMIT SET 21507 88TH AVE W EDMONDS, WA 98026 Drawn by: AB Checked: JH Date: 06/18/2021 Scale: As indicated Revisions: No. Date Remarks o RECEIVED _ Jun 21 2021 LD CITY OF EDMONDS M — DEVELOPMENT SERVICES DEPARTMENT ^ — V+ Z CD SITE " - SITE PLAN O `_Al — r ■ 0 Z — FIRST FLOOR DEMO PLAN 1/4" = 1'-0" CV CV V CV (V O Q W co 0 1' 2' 4' 8' 10' DEMO LEGEND: DEMOLISH (D) DEMOLISH FIXTURE (S) SALVAGE FIXTURE (E) WALL GENERAL NOTES: 1.DEMO (E) LIGHTING, EXCEPT FOR (E) TRACK LIGHTING & (E) RECESSED LIGHT FIXTURES UNO. 3. DEMOLISH GWB AS REQUIRED TO INSTALL ELEC AND DATA. Domestic dishwashing machines shall discharge indirectly through an air gap fitting a or above the flood -level of the sink or drainboard into a waste receptor, a wye branch fitting on the tailpiece of a kitchen sink, or a dishwasher connection of a food waste grinder — (E) WD DECK N_ 0o N (E) CHIMNEY (E) LIVING ROOM (E) BEDROOM 281 SF 195 SF /(E) CARPET E BATH E BATH 40 SF 40 SF FLOORING TRANSITION 002 /(E) WD FLOOR 7 — % (E) HALL (E) BEDROOM 208 SF 123 SF KITCHEN DINING N 360 SIF 1X 5'-9" 4'-2" - FLOORING S/ r TRANSITION 5 (E) CARPET 7 R00 / C3' ------ A3.1 13 REFI 1 14 A3.1 15 F— co A3.1 SINK M L L (E) ATTIC r ti REFR ACCESS HATCH DW O MW - -L-�-- Roo (E) BEDROOM co OVEN 126 SF L J 24X48" SKYLIGHT; LOCATE `' co + BETWEEN (E) RAFTERS 2)114"ST FLOOR PLAN = 1-0 L r` 001 2' - 1" 100 CFM INTERMITTENT FAN 3' - 6" 31 IL (RANGE HOOD) 10'-1" 12'-1" 16-3"+/ 0 1' 2' 4' 8' 10' PLAN LEGEND (E) WALL NON -RATED WALL SD SMOKE DETECTOR PER IRC 314.1 S/ SMOKE AND CARB MONOXIDE ALARM PER IRC R314.1 AN R315.2 FAN PER M1505.5. (E) WD DECK S H K S A R C H I T E C T S 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com 5158 REGISTERED ARC ITECT JONATHAN H. HA U G STATF OF WASHI GTO ON D — 4.4 — JOSHUA & IHLAE ROSEN ROSEN KITCHEN REMODEL PERMIT SET 21507 88TH AVE W EDMONDS, WA 98026 Drawn by: AB Checked: JH Date: 06/18/2021 Scale: 1/4" = 1'-0" Revisions: No. Date Remarks o RECEIVED _ Jun 21 2021 LD CITY OF EDMONDS M _ DEVELOPMENT SERVICES DEPARTMENT r _ Cn c - DEMO AND " - FLOOR PLANS A2 CD U_ — ll— O01 01 Z (E) CHIMNEY (E) ASPHALT ROOF 23'-5 R002 R001 T.O. PLATE 16' - 8 1 /4" FIRST FLOOR (E) WD STAIR (E) WD DECK E] Ll Ll T.O. FOUNDATION WALL 2' 0" BASEMENT F.F. Oil WEST ELEVATION 1/8" = V-0" (E) WD DECK III II EAST ELEVATION 3 1/8" = V-0" co 0 1' 2' 4' 8' 10' DOOR SCHEDULE MARK FROM ROOM TO ROOM LEAF SIZE REMARKS W H D 001 KITCHEN DINING (E) DECK 3' - 0" 6' - 8" 2" SAFETY GLAZING; U-0.50 002 (E) BEDROOM (E) HALL 2' - 6" 6' - 8" 2" WINDOW SCHEDULE MARK TYPE WIDTH HEIGHT AREA U-VALUE COMMENTS R001 24" x 48" 2' - 0" 4' - 0" 0.30 R002 24" x 48" 2' - 0" 4' - 0" 0.30 WRO01 48" x 39" 4' - 0" 3' - 3" 14 SF 0.30 WRO02 60" x 39" 5' - 0" 3' - 3" 17 SF 0.30 GLAZING NOTES: 1. DIMENSIONS LISTED ARE FRAME DIMENSIONS UNLESS OTHERWISE NOTED. 2. CONTRACTOR TO COORDINATE ROUGH OPENING DIMENSIONS WITH FRAME SIZE, ROUGH FRAMING, AND FINISH REQUIREMENTS. 3. WINDOWS ARE NFRC CERTIFIED. 4. ALL GLAZING WITHIN 18" OF INTERIOR FLOOR, EXTERIOR WALKING SURFACE, OR WITHIN 24" OF A DOOR IN ANY POSITION TO BE SAFETY/TEMPERED GLASS 5. PROVIDE CONTINUOUS AIR SEAL AT ALL WINDOWS, DOORS, WALL AND ROOF PENETRATIONS. 23'-5 T.O. PLATE 16' - 8 1 /4" FIRST FLOOR 9' - 0 1 /4" T.O. FOUNDATION WALL 2'-Oil V III III NORTH ELEVATION (E) CHIMNEY (E) ASPHALT ROOF (E) WD STAIR 1/8" = V-0" 0 1' 2' 4' 8' 10, (E) CHIMNEY (E) CHIMNEY 23' - 5 5/8° (E) ASPHALT ROOF 3' - 5 5/8" (E) ASPHALT ROOFING R001 T.O. PLATE T.O. PLATE 16' - 8 1 /4" T 16' - 8 1 /4" ❑ ❑ ❑ ❑� (E) STAIR T - — — — — — — 001 — — — — — — — — — 7F i FIRST FLOOR J1, FIRST FLOOR 9' - 01/4" 9' - 01/4" (E) WD DECK, DASHED \ FOR CLARITY T.O. FOUNDATION WALL T.O. FOUNDATION WALL — — - - — 2'_p 2'_p — SEMENT F.F. BASEMENT F.F. Oil oil -III III III III III III III III III III III III III III III II III III III III III III III III III III III III III III SOUTH ELEVATION 0 1' 2' 4' 8' 10' 1/8" = 1'-0" 0 1' 2' 4' 8' 10, S H K S A R C H I T E C T S 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com _F ERED ECT UG TO JOSHUA & IHLAE ROSEN ROSEN KITCHEN REMODEL PERMIT SET 21507 88TH AVE W EDMONDS, WA 98026 Drawn by: AB Checked: JH Date: 06/18/2021 Scale: Revisions: No. Date Remarks o RECEIVED LD — Jun 21 2021 CITY OF EDMONDS M _ DEVELOPMENT SERVICES DEPARTMENT fir^ _ V+ c - EXTERIOR " - ELEVATIONS O `_ — r A300 O Z_ co C0 DEMO (E) DROPPED CEILING ------ REF OVEN / \ 0 _ T.O. PLATE 16' - 81 /4" FIRST FLOOR 2'-6" L 3'-01/4" 2'-9" L 3'-0" 11' - 5 1/8" KITCHEN - EAST ELEVATION 1/4" = V-0" - 0 1/2"ice 4'- 2 1/2" 11 2'- 3" i. 3' - 6" REFR i GAS 001 `V RANGE ---------------- o e 2'-3" 1_2'-0" SINK 4'-2" 1'-9" 9" 3'-0" Ll1-6"1'-0"_2'-0" 5 KITCHEN - SOUTH ELEVATION 1/4" = V-0" 4'-3" 1 7'-3" DEMO (E) 1 DROPPED CEILING I I ROO ROO 0 0 0O e o /SINK\ o F I DW / 2'-1" � 3'-0011� Lf 2'-6" �21-011 �11-611� 21_6" 21_6" 14'-0" KITCHEN - WEST ELEVATION 1/4" = 1'-0" AUK TNK'_ MW o 2' 0" 2' _ 6" FIRST FLOOR OIL 9'- 01 /4" 2'-0" ISLAND - WEST ELEVATION 1/4" = 1'-0" o r r 4' a' 0 1' 2' 4' 8' 100 CFM INTERMITTENT FAN (RANGE HOOD) T.O. PLATE 16' - 8 1/4" FIRST FLOOR 9' - 01/4" MAKEUP AIR VENT AS REQUIRED PER IRC M1503.6 0 1' 2' 4' 8' T.O. PLATE 16'- 8 1/4" FIRST FLOOR OL 9' - 01 /4" 0 1' 2' 4' 8' /00\ 6" 2' - 0" FIRST FLOOR 9' - 01 /4" 14 ISLA oD -EAST �L��ATI�l — o 8' BUILDING SECTION 3/4" = 1'-0" ENERGY CODE ANALYSIS 2018 WASHINGTON STATE ENERGY CODE (TABLE R402.1.1, CLIMATE ZONE, 4C - KING) FENESTRATION U-FACTOR U-0.30 SKYLIGHT U-FACTOR U-0.50 GLAZED FENESTRATION SHGC NR CEILING R-49 WOOD FRAME WALL R-21 INT BELOW -GRADE WALL R-10/15/21 INT. SLAB R-10, DEPTH 2 ft (E) VENT BLOCKING (E) ROOF ASSEMBLY (E) FASCIA AND GUTTER T.O. PLATE 16'- 8 1/4" (E) TOP PLATE (2) 2X6 HEADER, TYP @ ALL NEW WINDOWS AND DOORS WINDOW PER SCHEDULE (E) WALL ASSEMBLY FINISH FLOOR FIRST FLOOR 9'- 0 1/4" (E) WALL ASSEMBLY 0 8" 1' 2' 3' S H K S A R C H I T E C T S 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com _ 5258 REGISTERED ARC ITECT JONATHAN H. HA U G STATIF OF WASHI GTO JOSHUA & IHLAE ROSEN ROSEN KITCHEN REMODEL PERMIT SET 21507 88TH AVE W EDMONDS, WA 98026 Drawn by: Author Checked: Checker Date: 06/18/2021 Scale: As indicated Revisions: No. Date Remarks o RECEIVED LD — Jun 21 2021 CITY OF EDMONDS M — DEVELOPMENT SERVICES li DEPARTMENT y - BUILDING c - SECTIONS AND " - ELEVATIONS O U — O A301 Z —