Loading...
APPROVED BLD ENG PLN_RESUB 2-Architectural & Site Plan 12.10.2021APPROVED BY PLANNING 4l •-"`" 4 yL Dec 15 2021 T-MOBILE SITE NUMBER: T-MOBILE SITE NAME: T-MOBILE PROJECT: SITE INFORMATION CROWN CASTLE USA INC. SITE NAME: ED LARGE/CARNELL MP SE01626B FIVE CORNERS FIRESTATION ANCHOR ALL WORK SUBJECT APPROVED TO FIELD PLANSINSPECTION FOR MUST BE CODE COMPLIANCE I ON JOB SITE SITE ADDRESS: 8505 BOWDOIN WAY EDMONDS, WA 98026 COUNTY: SNOHOMISH MAP/PARCEL #: 0373600501802 AREA OF CONSTRUCTION: EXISTING LATITUDE: 47.80682800 LONGITUDE: -122.34876800 LAT/LONG TYPE: NAD83 GROUND ELEVATION: 440.0' CURRENT ZONING: 483 JURISDICTION: SNOHOMISH COUNTY OCCUPANCY CLASSIFICATION: U TYPE OF CONSTRUCTION: IIB A.D.A. COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION PROPERTY OWNER: CITY OF EDMONDS 250 5TH AVE N. EDMONDS, WA 98020 TOWER OWNER: CROWN CASTLE USA, INC. 2000 CORPORATE DRIVE CANONSBURG, PA 15317 CARRIER/APPLICANT: T-MOBILE 8960 ALDERWOOD ROAD PORTLAND, OR 97220 ELECTRIC PROVIDER: SNOHOMISH PUD TELCO PROVIDER: VERZION TELECOM PROJECT TEAM A&E FIRM: P. MARSHALL & ASSOCIATES, LLC 6801 PORTWEST DR. STE 100 HOUSTON, TX 77024 (713) 677-0964 CROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 USA INC. DISTRICT SEATTLE, WA 98109 CONTACTS: ALICIA POWERS - PROJECT MANAGER (206) 336-3218 PAUL LONG - CONSTRUCTION MANAGER (206) 388-9090 NOTE: PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN NOC AT (800) 788-7011 & CROWN CONSTRUCTION MANAGER. CALL WASHINGTON ONE CALL (800) 424-5555 p CALL 3 WORKING DAYS BEFORE YOU DIG! DRAWING INDEX SHEET # SHEET DESCRIPTION T-1 TITLE SHEET T-2 GENERAL NOTES C-1.1 OVERALL SITE PLAN C-1.2 EXISTING SITE PLAN C-1.3 FINAL SITE PLAN C-2 EXISTING & FINAL ELEVATIONS C-3 ANTENNA SCHEDULES & PLANS C-4 EXISTING & FINAL PLUMBING DIAGRAMS C-5 - C-10 EQUIPMENT SPECS E-1 PANEL SCHEDULE AND ONE LINE DIAGRAM E-2 INTERSECT 200 AMP PPC W/ BUILT-IN CAM LOK BOX G-1 ANTENNA GROUNDING DIAGRAM G-2 GROUNDING DETAILS G-3 GROUNDING DETAILS ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR FULL SIZE. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. IN APPROVALS APPROVAL SIGNATURE DATE PROJECT MGR T-MOBILE RF ENGINEER SITE ACQUISITION CONSTRUCTION MGR SITE OWNER T-MOBILE DEVELOPMENT MGR T-MOBILE CONSTRUCTION MGR T-MOBILE OPS MGR T-MOBILE REGULATORY REVIEW T-MOBILE PROJECT MGR T-MOBILE PERMITTING THE PARTIES ABOVE HEREBY APPROVE AND ACCEPT THESE DOCUMENTS AND AUTHORIZE THE CONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN. ALL CONSTRUCTION DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT AND ANY CHANGES AND MODIFICATIONS THEY MAY IMPOSE. BUSINESS UNIT #: SITE ADDRESS: COUNTY: SITE TYPE: TOWER HEIGHT: 824070 8505 BOWDOIN WAY EDMONDS, WA 98026 SNOHOMISH MONOPOLE 109' -2" LOCATION MAP City Of Edmonds Building Department Work CELLULAR ALTERATIONS -------------------------------------------------- Address 8505 BOWDOIN WAY --------------------------------------------------- Owner T-MOBILE ------------- Approved Date 12/17/2021 Building Official ; Eric. Carte-r Permit Number' - -- -- - BLD2021-1226 Nothing in the permit approval process shall be If � Brjdge Animal interpreted as allowing or permitting the maintenanceerral cmr of any currently existing illegal, nonconforming or Edmonds Veterinary Hospital unpermitted building, structure or site condition which 9 is outside the scope of the permit application, regardless of whether such building, structure or condition is 9Namaste Salon 5 Cbmers Tak •• el l Delivery D � ���'� shown on the site plan or drawing. Such building, oLri structure or condition may be the subject of a separate enforcement action. 824070 Bin Cain and 9 Assoclales, Inc C6 E Bar DOJO rakeout Delivery w�!. � Vt 60,"' y Noodle Hut a Tekev l ENGINEERING DIVISION _ _— NO SCALE DRIVING DIRECTIONS: M i THE PURPOSE OF THIS PROJECT IS TO ENHANCE BROADBAND CONNECTIVITY AND CAPACITY TO THE EXISTING ELIGIBLE WIRELESS FACILITY. TOWER SCOPE OF WORK: • REMOVE (3) ANTENNAS • REMOVE (3) RRU'S • REMOVE (1) COVP • REMOVE (1) HYBRID CABLE • INSTALL (3) ANTENNAS • INSTALL (3) AHFIG RRU'S • INSTALL (2) HCS 2.0 J-BOX W/ BREAKOUT PENDANTS • INSTALL (2) 1-1/2" HYBRID CABLES GROUND SCOPE OF WORK: • REMOVE (1) EXISTING CABINET: (1) SSC CABINET • REMOVE (1) EXISTING H-FRAME MOUNTED RACK • REMOVE (2) AMOB UNITS • REMOVE (1) CSR 7210 SAS-MXP ROUTER • REMOVE (1) EXISTING 100A PPC • REMOVE (1) EXISTING 100A DISCONNECT • INSTALL (1) PURCELL HPL3 CABINET W/: (2) AMIA'S, (2) PSU 4813 VOLTAGE BOOSTER W/ (6) AMPLIFIERS & (1) CSR IXRE V2 ROUTER • INSTALL (1) PURCELL LB3 BATTERY CABINET W/ (4) BATTERY STRINGS • INSTALL EXTENDED 5'-0" UTILITY H-FRAME • INSTALL (1) TECH LIGHT • INSTALL (1) 200A DISCONNECT • INSTALL ICE BRIDGE W/ HEIGHT OF 12'-0" & 12" DIVING BOARD • REPLACE EXISTING 100A PPC W/ NEW 200 AMP PPC W/BUILT-IN CAM LOK BOX • RETAIN EXISTING FCOA CABINET W/ (3) FRIA's, (1) ESMB, & (1) FSME W�V'_'_At12/17/2021 DOCUMENTS ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: CODE TYPE CODE BUILDING MECHANICAL ELECTRICAL 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL MECHANICAL CODE 2020 NATIONAL ELECTRICAL CODE REFERENCE DOCUMENTS: STRUCTURAL ANALYSIS: TOWER ENGINEERING PROFESSIONALS DATED: 06/09/21 MOUNT ANALYSIS: VERTICAL STRUCTURES, INC. DATED: 05/17/21 RFDS REVISION: 10 DATED: 04/01 /21 ORDER ID: 558188 REVISION: 0 IT • • Mob ile• • •I 8960 ALDERWOOD ROAD PORTLAND, OR 97220 CROWN CC CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 D 0 0 P. MARSHALL & ASSOCIATES 6801 PORTWEST DR., SUITE 100 HOUSTON, TX 77024 T-MOBILE SITE NUMBER: SE01626B BU #: 824070 ED LARGE / CARNELL MP 8505 BOWDOIN WAY EDMONDS, WA 98026 EXISTING 109'-2" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./ Q A 06/14/21 JAH PRELIMINARY HS 0 07/09/21 CS FINAL CD HS 1 08/30/21 PA FINAL REVISION HS 2 09/13/21 CS FINAL REVISION HS 3 10/11/21 CS JDX REVISION VT 4 12/02/21 CS JDX REVISION VT 55949 WV-"-12/06/2021 UBI NUMBER: 604-106-184 RESUB Dec 10 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A JOB #: 21CCT7M-082 SHEET NUMBER: REVISION: CROWN CASTLE USA INC. SITE ACTIVITY REQUIREMENTS: I GENERAL NOTES: I ELECTRICAL INSTALLATION NOTES: 2. 3. 4. 5. e ri LO 11 12 13 14 15 16 17 18 19 20 21 22 NOTICE TO PROCEED- NO WORK SHALL COMMENCE PRIOR TO CROWN CASTLE USA INC. WRITTEN NOTICE TO PROCEED (NIP) AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN CASTLE USA INC. NOC AT 800-788-701 1 & THE CROWN CASTLE USA INC. CONSTRUCTION MANAGER. "LOOK UP" - CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT: THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGES OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR CROWN CASTLE USA INC. POC OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET. PRIOR TO THE START OF CONSTRUCTION, ALL REQUIRED JURISDICTIONAL PERMITS SHALL BE OBTAINED. THIS INCLUDES, BUT IS NOT LIMITED TO, BUILDING, ELECTRICAL, MECHANICAL, FIRE, FLOOD ZONE, ENVIRONMENTAL, AND ZONING. AFTER ONSITE ACTIVITIES AND CONSTRUCTION ARE COMPLETED, ALL REQUIRED PERMITS SHALL BE SATISFIED AND CLOSED OUT ACCORDING Q TO LOCAL JURISDICTIONAL REQUIREMENTS. ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS, RIGGING PLANS, CLIMBING PLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THE WORK CONTAINED HEREIN, AND SHALL MEET ANSI/ASSE Al0.48 (LATEST EDITION); FEDERAL, STATE, AND LOCAL REGULATIONS; AND ANY APPLICABLE INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIES BEING PERFORMED. ALL RIGGING PLANS SHALL ADHERE TO ANSI/ASSE Al0.48 (LATEST EDITION) AND CROWN CASTLE USA INC. STANDARD CED-STD-10253, INCLUDING THE REQUIRED INVOLVEMENT OF A QUALIFIED ENGINEER FOR CLASS IV CONSTRUCTION, TO CERTIFY THE SUPPORTING STRUCTURE(S) IN ACCORDANCE WITH ANSI/TIA-322 (LATEST EDITION). ALL SITE WORK TO COMPLY WITH QAS-STD-10068 "INSTALLATION STANDARDS FOR CONSTRUCTION ACTIVITIES ON CROWN CASTLE USA INC. TOWER SITE," CED-STD-10294 "STANDARD FOR INSTALLATION OF MOUNTS AND APPURTENANCES," AND LATEST VERSION OF ANSI/TIA-1 01 9-A-2012 "STANDARD FOR INSTALLATION, ALTERATION, AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS." IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY CROWN CASTLE USA INC. PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION E) CONSTRUCTION SAFETY PROCEDURES. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND PROJECT SPECIFICATIONS, LATEST APPROVED REVISION. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH AT THE COMPLETION OF THE WORK. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF CONTRACTOR, TOWER OWNER, CROWN CASTLE USA INC., AND/OR LOCAL UTILITIES. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE REQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED ON INDIVIDUAL PIECES OF EQUIPMENT, ROOMS, AND SHELTERS. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT AND TOWER AREAS. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION AS SPECIFIED ON THE CONSTRUCTION DRAWINGS AND/OR PROJECT SPECIFICATIONS. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. GREENFIELD GROUNDING NOTES: 1 2 3 4 5 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR: GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION CARRIER: T-MOBILE TOWER OWNER: CROWN CASTLE USA INC. 2. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS OR SIMILAR LOCALITIES. IT IS ASSUMED THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE WHO HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, FORMWORK, SHORING, ETC. SITE VISITS BY THE ENGINEER OR HIS REPRESENTATIVE WILL NOT INCLUDE INSPECTION OF THESE ITEMS AND IS FOR STRUCTURAL OBSERVATION OF THE FINISHED STRUCTURE ONLY. 4. NOTES AND DETAILS IN THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, AND/OR AS PROVIDED FOR IN THE CONTRACT DOCUMENTS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES, AND SPECIFICATIONS, THE GREATER, MORE STRICT REQUIREMENTS, SHALL GOVERN. IF FURTHER CLARIFICATION IS REQUIRED CONTACT THE ENGINEER OF RECORD. 5. SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO ASSIST IN THE FABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY THE DIMENSIONS, MEASUREMENTS, AND/OR CLEARANCES SHOWN IN THE CONSTRUCTION DRAWINGS PRIOR TO FABRICATION OR CUTTING OF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS. IF IT IS DETERMINED THAT THERE ARE DISCREPANCIES AND/OR CONFLICTS WITH THE CONSTRUCTION DRAWINGS THE ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS POSSIBLE. 6. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CROWN CASTLE. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 9. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 10. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CARRIER AND CROWN CASTLE PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 11. CONTRACTOR IS TO PERFORM A SITE INVESTIGATION AND IS TO DETERMINE THE BEST ROUTING OF ALL CONDUITS FOR POWER, AND TELCO AND FOR GROUNDING CABLES AS SHOWN IN THE POWER, TELCO, AND GROUNDING PLAN DRAWINGS. 12. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF CROWN CASTLE USA INC. 13. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 14. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. CONCRETE, FOUNDATIONS, AND REINFORCING STEEL: 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACI 336, ASTM Al84, ASTM Al85 AND THE DESIGN AND CONSTRUCTION SPECIFICATION FOR CAST -IN -PLACE CONCRETE. 2. UNLESS NOTED OTHERWISE, SOIL BEARING PRESSURE USED FOR DESIGN OF SLABS AND FOUNDATIONS IS ASSUMED TO BE 1000 psf. 3. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (fc) OF 3000 psi AT 28 DAYS, UNLESS NOTED OTHERWISE. NO MORE THAN 90 MINUTES SHALL ELAPSE FROM BATCH TIME TO TIME OF PLACEMENT UNLESS APPROVED BY THE ENGINEER OF RECORD. TEMPERATURE OF CONCRETE SHALL NOT EXCEED 900f AT TIME OF PLACEMENT. 4. CONCRETE EXPOSED TO FREEZE -THAW CYCLES SHALL CONTAIN AIR ENTRAINING ADMIXTURES. AMOUNT OF AIR ENTRAINMENT TO BE BASED ON SIZE OF AGGREGATE AND F3 CLASS EXPOSURE (VERY SEVERE). CEMENT USED TO BE TYPE II PORTLAND CEMENT WITH A MAXIMUM WATER -TO -CEMENT RATIO (W/C) OF 0.45. 5. ALL STEEL REINFORCING SHALL CONFORM TO ASTM A615. ALL WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM Al85. ALL SPLICES SHALL BE CLASS "B" TENSION SPLICES, UNLESS NOTED OTHERWISE. ALL HOOKS SHALL BE STANDARD 90 DEGREE HOOKS, UNLESS NOTED OTHERWISE. YIELD STRENGTH (Fy) OF STANDARD DEFORMED BARS ARE AS FOLLOWS: #4 BARS AND SMALLER.................................................................................... 40 ksi #5 BARS AND LARGER...................................................................................... 60 ksi 6. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH ....................... 3" CONCRETE EXPOSED TO EARTH OR WEATHER: #6 BARS AND LARGER.....................................................................................21, #5 BARS AND SMALLER.......................................................................... 1-1 /2„ CONCRETE NOT EXPOSED TO EARTH OR WEATHER: SLAB AND WALLS......................................................................................... 3/4" BEAMS AND COLUMNS............................................................................. 1-1 /2„ 7. A TOOLED EDGE OR A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, UNLESS NOTED OTHERWISE, IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. THE CONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTAL RESISTANCE TO EARTH TESTING (PER IEEE 1 100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH #6 COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED COPPER FOR OUTDOOR BTS. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED COPPER UNLESS OTHERWISE INDICATED. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. USE OF 900 BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 450 BENDS CAN BE ADEQUATELY SUPPORTED. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. BOND ALL METALLIC OBJECTS WITHIN 6 ft OF MAIN GROUND RING WITH (1) #2 BARE SOLID TINNED COPPER GROUND CONDUCTOR. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e., NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN 3/4" NON-METALLIC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD -WELD TERMINATION POINT. THE EXPOSED END OF THE CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUNDING RING, TO THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY). l . ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS NEC AND ALL APPLICABLE FEDERAL STATE AND LOCAL CODES/ORDINANCES. 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDS ARE ELIMINATED. 3. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. 4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. 4.1. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO REQUIREMENT OF THE NATIONAL ELECTRICAL CODE. 4.2. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED, 22,000 AIC MINIMUM. VERYIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE RATING OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PRE THE GOVERNING JURISDICTION. 5. EACH END OF EVERY POWER PHASE CONDUCTOR, GROUNDING CONDUCTOR, AND TELCO CONDUCTOR OR CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE 3M BRAND 1 2" PLASTIC ELECTRICAL TAPE WITH UV PROTECTION OREQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA. 6. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH LAMICOID TAGS SHOWING THEIR RATED VOLTAGE, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING AND BRANCH CIRCUIT ID NUMBERS (i.e. PANEL BOARD AND CIRCUIT ID'S). 7. PANEL BOARDS (ID NUMBERS) SHALL BE CLEARLY LABELED WITH PLASTIC LABELS. 8. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. 9. ALL POWER AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR (#14 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR (#6 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 11. POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI -CONDUCTOR, TYPE SOOW CORD (# 14 OR LARGER) UNLESS OTHERWISE SPECIFIED. 12. POWER AND CONTROL WIRING FOR USE IN CABLE TRAY SHALL BE MULTI -CONDUCTOR, TYPE TC CABLE (# 14 OR LARGER), WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 13. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75° C (90° C IF AVAILABLE). 14. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND NEC. 15. ELECTRICAL METALLIC TUBING (EMT), INTERMEDIATE METAL CONDUIT (IMC), OR RIGID METAL CONDUIT (RMC) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. 16. ELECTRICAL METALLIC TUBING (EMT) OR METAL -CLAD CABLE (MC) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. 17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90s AND ALL APPROVED ABOVE GRADE PVC CONDUIT. 18. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT ACCEPTABLE. 20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND THE NEC. 21. WIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS (WIREMOLD SPECMATE WIREWAY). 22. SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER (PANDUIT TYPE E OR EQUAL). 23. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON -PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES (i.e. POWDER -ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. 24. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET STEEL. SHALL MEET OR EXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3R (OR BETTER) FOR EXTERIOR LOCATIONS. 25. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED OR NON -CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 26. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2 (NEWEST REVISION) AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 27. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR CROWN CASTLE USA INC. BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. 28. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY. 29. INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW "T-MOBILE". 30. ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED. CONDUCTOR COLOR CODE SYSTEM CONDUCTOR COLOR 120/240V, 10 A PHASE BLACK B PHASE RED NEUTRAL WHITE GROUND GREEN 120/208V, 30 A PHASE BLACK B PHASE RED C PHASE BLUE NEUTRAL WHITE GROUND GREEN 277/480V, 30 A PHASE BROWN B PHASE ORANGE OR PURPLE C PHASE YELLOW NEUTRAL GREY GROUND GREEN DC VOLTAGE POS (+) RED** NEG (-) BLACK** * SEE NEC 210.5(C) (1) AND (2) ** POLARITY MARKED AT TERMINATION ABBREVIATIONS: ANT ANTENNA (E) EXISTING FIF FACILITY INTERFACE FRAME GEN GENERATOR GPS GLOBAL POSITIONING SYSTEM GSM GLOBAL SYSTEM FOR MOBILE LTE LONG TERM EVOLUTION MGB MASTER GROUND BAR MW MICROWAVE (N) NEW NEC NATIONAL ELECTRIC CODE (P) PROPOSED PP POWER PLANT QTY QUANTITY RECT RECTIFIER RBS RADIO BASE STATION RET REMOTE ELECTRIC TILT RFDS RADIO FREQUENCY DATA SHEET RRH REMOTE RADIO HEAD RRU REMOTE RADIO UNIT SIAD SMART INTEGRATED DEVICE TMA TOWER MOUNTED AMPLIFIER TYP TYPICAL UMTS UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM W.P. WORK POINT APWA UNIFORM COLOR CODE: WHITE PROPOSED EXCAVATION TEMPORARY SURVEY MARKINGS ELECTRIC POWER LINES, CABLES, CONDUIT, AND LIGHTING CABLES YELLOW GAS, OIL, STEAM, PETROLEUM, OR GASEOUS MATERIALS COMMUNICATION, ALARM OR SIGNAL LINES, CABLES, OR CONDUIT AND TRAFFIC LOOPS POTABLE WATER RECLAIMED WATER, IRRIGATION, AND SLURRY LINES SEWERS AND DRAIN LINES IT • • Mob 'Ile • • •I 8960 ALDERWOOD ROAD PORTLAND, OR 97220 C i� CROWN v CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 p0 P. MARSHALL &ASSOCIATES 6801 PORTWEST DR., SUITE 100 HOUSTON, TX 77024 T-MOBILE SITE NUMBER: SE01626B BU #: 824070 ED LARGE / CARNELL MP 8505 BOWDOIN WAY EDMONDS, WA 98026 EXISTING 109'-2" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 06/14/21 JAH PRELIMINARY HS 0 07/09/21 CS FINAL CD HS 1 08/30/21 PA FINAL REVISION HS 2 09/13/21 CS FINAL REVISION HS 3 10/11/21 CS JDX REVISION VT 4 12/02/21 CS JDX REVISION VT r WII� r O`er I? 55949 WTTg -12/06/2021 UBI NUMBER: 604-106-184 RESUB Dec 10 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A JOB #: 21CCT7M-082 SHEET NUMBER: REVISION: APN: 00373600501705 .• �T 4 APN: 00373600501708 ka APN: 00373600501707 O ,t Z Io I° x IO � I APN: 00373600400101 APN: 00613400000100 = 01 W. APN: 00373600400102 P"�P- , 0 Blue hatched area (end of the road) is owned by the condominiums over the fence and is not city right of way. pr�44,00\\A \N P�z APN: � 00613400000201 1 v/ hA A6 LW �� APN: 0373600501906 G 1 9 I ..i APN: 00613400000500 APN: APN: 00613400000400 00613400000301 ' .•_-� � •�` 1 y _ �' � `tip APN: 00613400000802 , 00613400000202ILK APN: 00953400099400 RIGHT OF WAY PERMIT NEEDED Shaded area is public right of way. Any use of the right of way including staging or parking of construction related vehicles requires a right of way permit. Please contact engineeringpermits@edmondswa.gov for application if applicable. OVERALL SITE PLAN SCALE: 20' 10' 0 20' 1"=W-0" (FULL SIZE) 1"=40'-0" (11x17) N SITE PLAN DISCLAIMER: PROPERTY LINES AND STRUCTURES HAVE BEEN DIGITIZED FROM PREVIOUS PLAN SETS. CROWN CASTLE USA INC. HAS NOT COMPLETED A SITE SURVEY AND THEREFORE MAKES NO CLAIMS AS TO THE ACCURACY OF INFORMATION DEPICTED ON THIS SHEET. M I IT • • Mob ile• • •I 8960 ALDERWOOD ROAD PORTLAND, OR 97220 CCCROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 D 0 O P. MARSHALL & ASSOCIATES 6801 PORTWEST DR., SUITE 100 HOUSTON, TX 77024 T-MOBILE SITE NUMBER: SE01626B BU #: 824070 ED LARGE/CARNELL MP 8505 BOWDOIN WAY EDMONDS, WA 98026 EXISTING 109'-2" MONOPOLE ISSUED FOR: TE DRWN DESCRIPTION DES./ Q 4/21 JAH PRELIMINARY HS 9/21 L CS FINAL CD HS 0/21 PA FINAL REVISION HS 3/21 CS FINAL REVISION HS /21 CS JDXREVISION VT /21 CS JDX REVISION VT r wrt„� r 55949 WV-"-12/06/2021 UBI NUMBER: 604-106-184 RESUB Dec 10 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A JOB #: 21CCT7M-082 SHEET NUMBER: REVISION: • M HIGHEST APPURTENANCE OF STRUCTURE ELEV. 1 19'-0" )VIED EXISTING TOWER ELEVATION • HIGHEST APPURTENANCE OF STRUCTURE ELEV. 1 19'-0" T-MOBILE ANTENNA TIP HEIGHT FI F\/ 1 1 A'-O" MOUNT ANALYSIS NOTES: 1. THE DESIGN DEPICTED IN THESE DRAWINGS IS VALID WHEN ACCOMPANIED BY A CORRESPONDING PASSING MOUNT ANALYSIS. 2. CONSTRUCTION MANAGER / GENERAL CONTRACTOR SHALL REVIEW THE MOUNT ANALYSIS FOR ANY CONDITIONS PRIOR TO INSTALLATION. 3. ANY REQUIRED MOUNT MODIFICATION DESIGN OR MOUNT REPLACEMENT SHALL BE APPROVED BY EOR. EXISTING GRADE "LOOK UP" - CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT: THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGES OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR CROWN CASTLE USA INC. POC OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET. ELEV. 0'-0" 0 I (E) T-MOBILE FEEDLINES (6) COAX CABLES (1-5/8") (±175' CABLE LENGTH) (P) T-MOBILE FEEDLINES: (2) 1-1/2" HCS 2.0 TRUNK CABLE (±175' LF) (E) T-MOBILE FEEDLINE (1) GPS COAX CABLES (1 /4") FINAL TOWER ELEVATION SCALE: 3/32"=l'-0" (FULL SIZE) 8' 4' 0 8' 3/64"=l'-0" (11x17) T • •Mobile • • •I 8960 ALDERWOOD ROAD PORTLAND, OR 97220 CROWN CC CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 Pm P. MARSHALL &ASSOCIATES 6801 PORTWEST DR., SUITE 100 HOUSTON, TX 77024 T-MOBILE SITE NUMBER: SE01626B BU #: 824070 ED LARGE / CARNELL MP 8505 BOWDOIN WAY EDMONDS, WA 98026 EXISTING 109'-2" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./ Q A 06/14/21 JAH PRELIMINARY HS 0 07/09/21 CS FINAL CD HS 1 08/30/21 PA FINAL REVISION HS 2 09/13/21 CS FINAL REVISION HS 3 10/11/21 CS JDX REVISION VT 4 12/02/21 CS JDX REVISION VT r wrt„� r 55949 WV-"-12/06/2021 UBI NUMBER: 604-106-184 RESUB Dec 10 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A JOB #: 21CCT7M-082 SHEET NUMBER: REVISI4 ON: MOUNT ANALYSIS NOTES: 1. THE DESIGN DEPICTED IN THESE DRAWINGS IS VALID WHEN ACCOMPANIED BY A CORRESPONDING PASSING MOUNT ANALYSIS. 2. CONSTRUCTION MANAGER / GENERAL CONTRACTOR SHALL REVIEW THE MOUNT ANALYSIS FOR ANY CONDITIONS PRIOR TO INSTALLATION. 3. ANY REQUIRED MOUNT MODIFICATION DESIGN OR MOUNT REPLACEMENT SHALL BE APPROVED BY EOR. ANTENNA AND CABLE SCHEDULE SCALE: NOT TO SCALE (E) (3) T-ARM MOUNTS TO REMi (E) T-MOBILE AHLOA MOUNTED TO T-ARM MOUNT TO REMAIN (3 TOTAL, 1 PER SECTOR) (E) T-MOBILE LARI TOBEF �25C EXISTING ANTENNA SCHEDULE ANTENNA SECTOR POS. TECHNOLOGY CRAID AZIMUTH MANUFACTURER ANTENNA MODEL TOWER MOUNTED EQUIPMENT FEEDLINE TYPE ALPHA Al L700/L600/N600/ 1 12'-0" 0° COMMSCOPE FFHH-65C-R3 (1) AHLOA/ (1) FXFB COAX G1900/U2100 ALPHA A2 - 1 12'-0" 0° ANDREW TMBXX-6516-A2M - HIGH CAP CABLE ALPHA A3 L2100 112'-0" 0° ANDREW TMBXX-6516-A2M (1) FRIG SHARED HIGH CAP CABLE ALPHA A4 - - - - - - - BETA B1 L700/L600/N600/ 1 12'-0" 1200 COMMSCOPE FFHH-65C-R3 (1) AHLOA COAX G1900/U2100 BETA B2 - 1 12'-0" 1200 ANDREW TMBXX-6516-A2M _ SHARED HIGH CAP CABLE BETA B3 -2100 - - ANDREW TMBXX-6516-A2M (1) FRIG SHARED HIGH CAP CABLE BETA B4 - - - - - - - GAMMA Cl L700/L600/N600/ 112'-0" 2500 COMMSCOPE FFHH-65C-R3 (1) AHLOA COAX G1900/U2100 GAMMA C2 - 1 12'-0" 2500 ANDREW TMBXX-6516-A2M _ SHARED HIGH CAP CABLE GAMMA C3 L2100 - - ANDREW TMBXX-6516-A2M (1) FRIG SHARED HIGH CAP CABLE GAMMA C4 - - - - - - - PROPOSED ANTENNA SCHEDULE SECTOR POS. TECHNOLOGY AZIMUTH NTT ANTENNA MODEL TOWER MOUNTED EQUIPMENT FEEDLINE TYPE CRADER TA MA ALPHA Al L700/L600/N600/ 1 12'-0" 0° COMMSCOPE FFHH-65C-R3 (1) AHLOA/ (1) FXFB COAX G1900/U2100 ALPHA A2 L2100/L1900/ 1 17-0" 0° ANDREW TMBXX-6516-A2M (1) AHFIG HYBRID 2.0 CABLE N1900/N2100 ALPHA A3 L2500/N2500 1 12'-0" 0° NOKIA AEHC - HYBRID 2.0 CABLE ALPHA A4 - - - - - - - BETA Bl L700/L600/N600/ 112'-0" 1200 COMMSCOPE FFHH-65C-R3 (1) AHLOA COAX G1900/U2100 BETA B2 -2100/L1900/ 112'-0" 1200 ANDREW TMBXX-6516-A2M (1) AHFIG SHARED HYBRID N1900/N2100 2.0 CABLE BETA B3 L2500/N2500 1 12'-0" 1200 NOKIA AEHC _ SHARED HYBRID 2.0 CABLE BETA B4 - - - - - - - GAMMA Cl L700/L600/N600/ 112'-0" 2500 COMMSCOPE FFHH-65C-R3 (1) AHLOA COAX G1900/U2100 GAMMA C2 L2100/1-1900/ 112'-0" 2500 ANDREW TMBXX-6516-A2M (1) AHFIG SHARED HYBRID N 1900/N2100 2.0 CABLE GAMMA C3 L2500/N2500 1 17-0" 2500 NOKIA AEHC _ SHARED HYBRID 2.0 CABLE GAMMA C4 - - - - - - - EXISTING ANTENNA PLAN SCALE: NOT TO SCALE ICI T A A/%nii C A AITCA IAI A (P) T-MOBILE ANTENNA NOKIA - AEHC MOUNTED TO T-ARM MOUNT (3 TOTAL, 1 PER SECTOR) (E) (3) T-ARM MOUNTS (E) T-MOBILE AHLOA MOUNTED TO T-ARM MOUNT (3 TOTAL, 1 PER SECTOR) C' (P) T-MOBILE AHF TO T- (3 TOTAL, 1 (GAMn �250° AZIr (E) T ANDREV M (3 TO - FINAL ANTENNA PLAN SCALE: NOT TO SCALE TOWER LOADING SUMMARY STATUS CABLE TYPE SIZE LENGTH QUANTITY EXISTING - - - - EXISTING COAX 1 /4 175-0" 1 EXISTING COAX 1-5/8 175-0" 6 NEW HCS2.0TRUNK 1-1/2" 175-0" 2 FINAL CABLE QUANTITY: 9 ICI T AAr,Dll C AKITCKIKIA T • •Mobile • • •I 8960 ALDERWOOD ROAD PORTLAND, OR 97220 CROWN CC CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 P0 P. MARSHALL &ASSOCIATES 6801 PORTWEST DR., SUITE 100 HOUSTON, TX 77024 T-MOBILE SITE NUMBER: SE01626B BU #: 824070 ED LARGE / CARNELL MP 8505 BOWDOIN WAY EDMONDS, WA 98026 EXISTING 109'-2" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./ Q A 06/14/21 JAH PRELIMINARY HS 0 07/09/21 CS FINAL CD HS 1 08/30/21 PA FINAL REVISION HS 2 09/13/21 CS FINAL REVISION HS 3 10/11/21 CS JDX REVISION VT 4 12/02/21 CS JDX REVISION VT WTTg-12/06/2021 UBI NUMBER: 604-106-184 RESUB Dec 10 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A JOB #: 21CCT7M-082 C-3 L 4 1 SHEET NUMBER: REVISION: 11 /23/21, 11:06 AM SE0162613Anchor 10 2021-11-23 Configuration 6701A_R4_U21 (Alpha , Beta & Gamma) To E ------------------ Notes: EXISTING PLUMBING DIAGRAM SCALE: NOT TO SCALE FDD - Loband B12 (L700) — 5 MHz B71 (L600) —10 MHz B71 (N600) —10 MHz FDD - Midband B4 (L2100) — 20 MHz GS M PCS U MTS AWS Configuration 56791EZ_U21 * For 5G and LTE Airscale BB dimensioning refer to Fiber Port matrices. (Alpha , Beta & Gamma) LB + M:B Octo MB Quad Passive Antenna Passive Antenna Y L701 L19+L19 t 0 Li L21+AWS3 °J N21 0 N600 U21 AEHC LTE+5G B41 12 11 10 9 8 7 6 5 :4 3 2 1 Active Antenna AHFIG AWS+PCS AH LOA 700+600 HCS1.0 H Top ------------ Ground f, HCS2.0 HCS1.0 TowerTop Style 3CX TMA AWS/PCS ,.Diplexer FDD - Lowband IT • • Mob ile• 8960 ALDERWOOD ROAD PORTLAND, OR 97220 (CROWNDZ CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 P� P. MARSHALL &ASSOCIATES B 12 (L700) — 5 MHz 6801 PORTWEST DR., SUITE 100 B71 (L600) —10 MHz HOUSTON, TX 77024 B71 (N600) — 10 MHz T-MOBILE SITE NUMBER: 1- v a..,.1 SE01626B 134 (L2100) — 20 MHz B2 (1-1900) — 20 MHz B25 (L1900) — 20 MHz B66 (AWS3) — 5MHz BU #: 824070 TDD - Band 41 L2.5(2.5GHz)— 60 MHz N41(2.5GHz) — 100MHz +2nd carrier (<=80MHz) i Gamma,mins � i Beta 11 A01- I i Gai Beta y "p- -- FSMF UMTS AWS FINAL PLUMBING DIAGRAM 2 SCALE: NOT TO SCALE ED LARGE / CARNELL MP 8505 BOWDOIN WAY EDMONDS, WA 98026 EXISTING 109'-2" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./ Q A 06/14/21 JAH PRELIMINARY HS 0 07/09/21 CS FINAL CD HS 1 08/30/21 PA FINAL REVISION HS 2 09/13/21 CS FINAL REVISION HS 3 10/11/21 CS JDX REVISION VT 4 12/02/21 CS JDX REVISION VT WV-"-12/06/2021 UBI NUMBER: 604-106-184 RESUB Dec 10 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A JOB #: 21CCT7M-082 C-4 SHEET NUMBER: REVISI4 ON: NOKIA AEHC WEIGHT (WITHOUT MOUNTING HARDWARE): 99.2 LBS. SIZE (HxWxD): 35.43x22.83x8.26 IN. FRONT TOP NOKIA AEHC DETAIL SCALE: NOT TO SCALE SIDE HCS 2.0 J-BOX WEIGHT (WITHOUT MOUNTING HARDWARE): 23.5 LBS. SIZE (HxWxD): 14.Oxl6.Ox8.0 IN. HCS 2.0 J-BOX DETAILS 4 SCALE: NOT TO SCALE 7 n 7 it NOKIA AHFIG WEIGHT (WITHOUT MOUNTING HARDWARE): 79.4 LBS. SIZE (HxWxD): 27.6xl3.4x5.6 IN. 2 AHFIG SPECIFICATIONS SCALE: NOT TO SCALE • IAIIAIIAIIAIIAIIAIIAIIAIIAIIAIIIAlIAlOIAIIAIIAIIAI �G1�� G�1��1� ��O�G��� G���{�1��0� pit 11M NOKIA CSR IXR-E V2 ROUTER WEIGHT: 11.2 LBS. SIZE (HxWxD): 1.75xl 7.25xl 0.0 IN. NOKIA CS IXR-E V2 ROUTER 5 SCALE: NOT TO SCALE BASED BOX ASSEMBLY HEAT SHRINK TU 3RID CABLE HCS 2.0 FIBER FEED W/ PENDANT WEIGHT (WITHOUT MOUNTING HARDWARE): 23.5 LBS. SIZE (HxWxD): 14.0x16.Ox8.0 IN. HCS 2.0 FIBER FEED W/ PENDANT DETAIL SCALE: NOT TO SCALE 2 General Product Overview PSU 48 13 • ��+i{iii��i+it i� ate• • . Figure 1 Mounting bracket Bracketfor 19- rack installations. Bracket can be reversed. E DC in ut temnina Is Covered interlace for connecting power cables from the power distribution - External alarm port. Interface for connects alarm cable to site ex.emaI alarms. - Power switches =or swiwhi nq onfoff the corresponding DC out u-. - Fuse connectors Covered fuse rerrininals for corres on d ing DCoutput. = DC power outputs Covered term ina Is for connecting power cables to remote loads. -I Ground connector Grounds chassis T - -Mobile - Ericsson PSU 48 13 Voltage SoosterDesign Specification The general specifications fo - the PSU 48 13 are as follows_ Elleebii,call Operatirna Limits l Voltage -38.D - -58.5 VDC Input Voltage, naminal 48 VDC Input Current, max 166 A; 30 Atotal for all four-49V inputs Ourtp ut Voltage, fixed -58 VDC Ourtput Power, max_ 2t700 watts each EnvironmentalOperating Limits Temperature, operation 40 -+80 IC Temperature. storage 40 -+55 °C Temperature, trasport -40 - +7 0 'C Humidity, operation and storage 5% - 55% Altkude, operation and storage C - 4000 m cocllin'g ,ntemal farts Vibration E TS3M019-2 Shack ET-S C019-2 Drop ETS300019-2 EMC FCC Part 15 Safety U L 13238E-1 Raise a 9.8 bel sound peroer Lightning Protection 4 kA: I D-?350 Im 20 kA. 8 r2D ps Fuse O lions 30 A. 40 A, 50 A Mechanical Specification WeilqM s 7.8 k 17.2 1bj ❑irnensions H x W x❑ 44 x 483 x M mlm I X x 19.0' x 14.3" incaude brackets, oovar PSU Unit IC1t_ SKU 34132 1 rraq I.SR I i DCRn ;tmII Part Number Part Description Qty Comments I SPAR 911 93j3 D-C_ CONVERTERJPSU 41313 1 2 SNG 819IV1 CABLE LUGiPOwerdual lug 6 awl; Rcght angled 5 3 nc parts, facing hybfid Gable 3 SNG SIB 23/1 CABLE LUGJPewerdual IU9 4 awe Right angled 6 3 DC ports, facing hybrid cable 4.1 NFWG021/30 FUSE HOLDER/30A.8OV, UL 1 3 fuses in each kit 4.2 NFN95021140 FUSE HOLDER140A, 80V, UL 1 3 fuses in each kit 43 NFA195021150 FUSE HOLDEP r50A, 801V, UL 1 3 fuses in each kit PSU 4813 VOLTAGE BOOSTER SPECS PSU 4813 VOLTAGE BOOSTER WEIGHT: 17.2 LBS. SIZE (HxWxD): 1.7x19.0x14.4 IN. IT • • Mob ile• • •I 8960 ALDERWOOD ROAD PORTLAND, OR 97220 CROWN CC CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 P� P. MARSHALL &ASSOCIATES 6801 PORTWEST DR., SUITE 100 HOUSTON, TX 77024 T-MOBILE SITE NUMBER: SE01626B BU #: 824070 ED LARGE / CARNELL MP 8505 BOWDOIN WAY EDMONDS, WA 98026 EXISTING 109'-2" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./ Q A 06/14/21 JAH PRELIMINARY HS 0 07/09/21 CS FINAL CD HS 1 08/30/21 PA FINAL REVISION HS 2 09/13/21 CS FINAL REVISION HS 3 10/11/21 CS JDX REVISION VT 4 12/02/21 CS JDX REVISION VT WTT" -12/06/2021 UBI NUMBER: 604-106-184 RESUB Dec 10 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A JOB #: 21CCT7M-082 SHEET NUMBER: REVISION: SCALE: NOT TO SCALE NOKIA AMIA WEIGHT: 11.2 LBS. SIZE (HxWxD): 5.2xl 7.6xl 5.7 IN. SKU# 33389 - NOKIA AMIA 1 SCALE: NOT TO SCALE NOKIA ABIL WEIGHT (UNIT ONLY): 4.4 LBS. SIZE (HxWxD): l.lx8.6xl4.2 IN. SFP28 S-RFl S-RF2 ®mm®mmmmmmm®mm®mmm®mm mm �C mmm®mm®mm®mmmmmmm mm 0000000BO oO00000 ® 00 m m mwn o S-RF1 S-RF2 QSFP28 ,00000000000000000000000 0000000000000000 00 °o °o ® °o °o ® °000 ® oo ® 000 ® o CCD o o o°000n00000°o°00000°000°0000°000°o°o°° -------------- ®aa®oo®oo®oo®oo®o ® O o000000000000000000000000000000000000000 0 6 0000 ®°000® 0000® 0000® 0000 ®O .0 00000000000000000000 00 0® o°0°0°00°08°0°0°0°0°0°0°00 °o°o�°o R�O��® ��� O® 000 ® m O® 9 9999999 9 9 e999a 99 9 PROPOSED ABIL LOCATION SKU# 33617 - NOKIA ABIL SCALE: NOT TO SCALE 0 NOKIA ASIB WEIGHT (UNIT ONLY): 6.4 LBS. SIZE (HxWxD): 1.7x8.6xl 4.2 IN. 0000000000000000000000000000000000000000 COD p 000°0000°000000000°°°°000°°°°°°°°°o°°o°° o®oo®oo®aa®oo®o ® O O o®oo®oo®oo®oo®O ° o00000000000000000°00 0oo 00000oo000000000 o00000000000000 o00 O 00o0 000a00000000 0 ° o0 0 0 o® o ��O o® QQQ ® r m ® p p 9 e999999 9 99 e999B 99 B PROPOSED ASIB LOCATION SKU# 34104 - NOKIA ASIB SCALE: NOT TO SCALE NOKIA ABIC WEIGHT (UNIT ONLY): 5.8 LBS. SIZE (HxWxD): 1.7x8.6xl4.2 IN. RF2 RF4 RF6 RF8 0 0000000;L oo o o o 0oo0000oo0000000000o000oo o 08®00®08®88®oo®S° p p 0000000 0 oo°°°°°o°°°°°°oo°°°°°00000°°000 oo®oa®a°®oo®oo®o O 0 jT�� °o®°000®0000 °000®°o°o'��0 p000000000000000000000 00 0® 0000000000000000 ®oo® 0000000000000000 00 0 00000008(0jj0000000 0 00 0 0 p%-�oo����® -- o ��� O® �000 ®a m ® a 9999999 9 99 e9999 9e 9 p d PROPOSED ABIC LOCATION SKU# 34103 - NOKIA ABIC SCALE: NOT TO SCALE 0 0 0 0 0 0 0 0 0 0 NOKIA ABIA WEIGHT (UNIT ONLY): 4.6 LBS. SIZE (HxWxD): 1.1x8.6xl4.2IN. a.6.. RF1 RF2 RF3 RF4 RF5 RF6 00 0®00 0O0®0O0®0O0®oo°®00000000000000000 00000000 oo oo oo 00 °®oo®oo®oo®oo®oo0 0000000°00®°0°o0®°0 °00®°0000®O°o°a°v gloo-0 %000000000000000 00 °v°v O°O000°o°o°o°o°o°001-°o°o°o°0000o �Oo°o8 0 0 000 0O000 oI�==000 o0 00 °° 0 0 ov v o n00 ®®m o ®U ° ° oo ° m9 9 e999e99 9 99 a9e99 96 9 • O I PROPOSED ABIA LOCATION SKU# 33388 - NOKIA ABIA SCALE: NOT TO SCALE NOKIA ASIK WEIGHT (UNIT ONLY): 6.6 LBS. SIZE (HxWxD): 1.7x8.6xl4.2 IN. 0 0 0 0 0 0.6" I \" FAN LMP STATUS SEI EIF1 EIF2 00000000000000000000000000000000000000000 ap °00 v°v ®00 oo®oo®oo®oo®oo®ovv ap vv 000000000000000000 00000000000000000001 00 00 00 00 0 �v ®00 0000 0 00 00 00 oo ap0000000 vv 0 000000000000000000000000 00 oo®oo®oo®000000®000O d� O 0000000000000000 vv OO 00000o 0Oo00o 00o 000000000000800000000000 00O U 0 0 000 0 0 O 000 0 O _ � vv ®® 0 000 o®000 00 00 00 �o Ov uu -- O d� o ® � \J ll ll I ® o m Ov a e eeeeeee e e eee®e ®e e SKU# 33615 - NOKIA ASIK U SCALE: NOT TO SCALE C PROPOSED ASIKLOCATION • MTN m mMobllemm . 8960 ALDERWOOD ROAD PORTLAND, OR 97220 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 D 0 O P. MARSHALL & ASSOCIATES 6801 PORTWEST DR., SUITE 100 HOUSTON, TX 77024 T—MOBILE SITE NUMBER: SE01626B BU #: 824070 ED LARGE/CARNELL MP 8505 BOWDOIN WAY EDMONDS, WA 98026 EXISTING 109'-2" MONOPOLE L i ISSUED FOR: REV DATE DRWN DESCRIPTION DES./ Q A 06/14/21 JAH PRELIMINARY HS 0 112/02/21 07/09/21 CS FINAL CD HS 1 08/30/21 PA FINAL REVISION HS 2 09/13/21 CS FINAL REVISION HS 3 10/11/21 CS JDX REVISION VT 4 CS JDX REVISION VT r wrt„� r a(r13TEK'' S�" 14, ssj�NAL�� 12/06/2021 UBI NUMBER: 604-106-184 RESUB Dec 10 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A JOB #: 21CCT7M-082 SHEET NUMBER: REVISION: C - 6 L 4 500 WATT LITHk-.1 QUARTZ FLOOD LIG"T MOGUL SOCKET MOUNTING MANUFACTURER'S CABLE OR O SUITABLE FOR EXTENDED SUNLIGH METALLIC CABLE TERMINATIC EXISTING GATI WEATHER PROOF 60 MIN. ROTA LIGH 3/4" RGS CONDUIT FOR (3) ELECT #2 AWG BARE SOLID TINNE TC EXOTHER TO NI U- w w E UT > OF 4'-0" MAX. TO EACH POST CONTRACTOR TO VERIFY OVERALL LENGTH REQUIRED TO n ACCOMMODATE EQUIPMENT n PLAN VIEW ELEVATION 8"x8"x1/2" STEEL BASEPLATE---, NV�If�'W 1-1/2" GALV. SQUARE P1000 UNISTRUT RAIL (12 GA.) (TYP.) COORDINATE EXACT LOCATION IN FIELD 3" DIA. SCH 40 STAINLESS STEEL OR GALV. PIPE (TYP) /2" U-BOLT (TYP.) 3" DIA. SCH 40 STAINLESS STEEL OR GALV. PIPE (TYP C O N END CAP (TYP) 8"x8"x1/2" STEEL BASEPLATE (TYP.) WITH (4) 1/2" DIA. BOLTS WITH EPDXI ANCHOR AND 4" MIN. EMBEDMENT 1-1/2" END VIEW MOUNTING BRACKET (SUPPLIED W/ ANTENNA) ANTENNA MOUNTING PIPE INSTALLER NOTE: 1. ALL PIPES, BRACKETS, AND MISCELLANEOUS HARDWARE TO BE GALVANIZED UNLESS NOTED OTHERWISE. 2 ANTENNA MOUNTING DETAIL SCALE: NOT TO SCALE Frequency Bands & Sectors Frequency Band Colors Lowband - 600/700 ............. Oranw- PCs - 1900 AWS - 2100/1700 Gray Sector Colors Alpha Beta Gamma Delta Yellow Epsilon White Zeta • - NEW ANTENNA ZACKET ANTENNA) Alpha Sector Example AWS - 210011700 Lowband - 6001700 1 1 1 PCs -1900 Dual Band (PCS/AWS) IT • • Mob ile• • •I 8960 ALDERWOOD ROAD PORTLAND, OR 97220 CROWN CC CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 P0 P. MARSHALL &ASSOCIATES 6801 PORTWEST DR., SUITE 100 HOUSTON, TX 77024 T-MOBILE SITE NUMBER: SE01626B BU #: 824070 ED LARGE / CARNELL MP 8505 BOWDOIN WAY EDMONDS, WA 98026 EXISTING 109'-2" MONOPOLE ISSUED FOR: Lowband - 6001700 1 1 1 PCs -1900 Dual Band (PCS/AWS) IT • • Mob ile• • •I 8960 ALDERWOOD ROAD PORTLAND, OR 97220 CROWN CC CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 P0 P. MARSHALL &ASSOCIATES 6801 PORTWEST DR., SUITE 100 HOUSTON, TX 77024 T-MOBILE SITE NUMBER: SE01626B BU #: 824070 ED LARGE / CARNELL MP 8505 BOWDOIN WAY EDMONDS, WA 98026 EXISTING 109'-2" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./ Q A 06/14/21 JAH PRELIMINARY HS 0 07/09/21 CS FINAL CD HS 1 08/30/21 PA FINAL REVISION HS 2 09/13/21 CS FINAL REVISION HS 3 10/11/21 CS JDX REVISION VT 4 12/02/21 CS JDX REVISION VT r WTTg-12/06/2021 UBI NUMBER: 604-106-184 RESUB Dec 10 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A JOB #: 21CCT7M-082 SHEET NUMBER: REVISION: 3 WORK LIGHT WITH TIMER DETAIL SCALE: NOT TO SCALE 4 UTILITY H-FRAME )— SCALE: NOT TO SCALE RF JUMCAL PER COLOR CODING SE: NOT TO SCALE MOUNTING FOOTPRINT 21-611 PLAN VIEW 5/8"0 FOR INET ANCHORAGE 5/8"0 FOR TERY MOUNTING 811 21-811 891 VENDOR: PURCELL SYSTEMS INC MODEL: 2000005433 DIMENSIONS: 30.0"x30.0"x72.0" WEIGHT: 430 LBS (WITHOUT EQUIPMENT) NOTE - ADDITIONAL KNOCKOUTS MAY BE REQUIRED AND CAN BE DRILLED ON SITE AS NECESSARY ISO VIEW SHIPPING HOOKS TO BE REMOVED AFTER CABINET INSTALL CORRECT KNOCKOUT TOOL REQUIRED FOR PUNCHING KNOCKOUTS. DO NOT DRILL KNOCKOUTS THROUGH FRONT VIEW SIDE VIEW BACK VIEW PURCELL HPL3 POWER CABINET SPECIFICATIONS SCALE: NOT TO SCALE MOUNTING FOOTPRINT 21-6'1 PLAN VIEW 0 �ro 0 0 FRONT VIEW 9' )R ICHORAGE ISO VIEW SIDE VIEW VENDOR: PURCELL SYSTEMS INC MODEL: 2000005434 DIMENSIONS: 30.0"x30.0"x63.0" WEIGHT: 350 LBS (WITHOUT EQUIPMENT) PURCELL LB3 BATTERY CABINET SPECIFICATIONS SCALE: NOT TO SCALE SHIPPING HOOKS TO BE REMOVED AFTER CABINET INSTALL ;ORRECT KNOCKOUT 'OOL REQUIRED FOR 'UNCHING KNOCKOUTS. )O NOT DRILL :NOCKOUTS THROUGH T • •Mobile • • •I 8960 ALDERWOOD ROAD PORTLAND, OR 97220 CROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 p0 P. MARSHALL &ASSOCIATES 6801 PORTWEST DR., SUITE 100 HOUSTON, TX 77024 T-MOBILE SITE NUMBER: SE01626B BU #: 824070 ED LARGE / CARNELL MP 8505 BOWDOIN WAY EDMONDS, WA 98026 EXISTING 109'-2" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./ Q A 06/14/21 JAH PRELIMINARY HS 0 07/09/21 CS FINAL CD HS 1 08/30/21 PA FINAL REVISION HS 2 09/13/21 CS FINAL REVISION HS 3 10/11/21 CS JDX REVISION VT 4 12/02/21 CS JDX REVISION VT r wrt„� r WV-"-12/06/2021 UBI NUMBER: 604-106-184 RESUB Dec 10 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A JOB #: 21CCT7M-082 SHEET NUMBER: REVISIC-8 4 ON: SPECIFICATIONS VOLTAGE CAPACITY (AH) NOMINAL DIMENSIONS NOMINAL WEIGHT 8 HR TO 1.75 VPC @ 250 10 HR TO 1.8 VPC @ 250 INCHES MILLIMETERS A B C A B C LBS Kg 12 183 / 186 AH 187 / 190 AH 22.0 4.9 12.6 560 125 320 124.3 56.3 CONCRETE SLAB ELECTRICAL DATA SHORT INTERNAL MODEL NUMBER CIRCUIT RESISTANCE CURRENT (mOhms) NSB 190FT RED BATTERY 5000 A 2.8 FLOAT VOLTAGE CONSTANT VOLTAGE CHARGING IS RECOMMENDED. RECOMMENDED FLOAT VOLTAGE: 2.27 +/- 0.02 VPC. CHAPTER 12, SECTION 1206 ELECTRICAL ENERGY STORAGE SYSTEM 1206.2 SCOPE: STATIONARY STORAGE BATTERY SYSTEMS HAVING CAPACITIES EXCEEDING THE VALUES SHOWN IN TABLE 1206.2 SHALL COMPLY W/ SECTION 1206.2.1 THROUGH 1206.2.12.6, AS APPLICABLE. BATTERY STORAGE SYSTEM THRESHOLD QTY'S CATTERY TECHNOLOGY CAPACITY ALLOWED LEAD ACID, ALL TYPES 70 kWh (252 MEGAJOULES) AH = VOLTAGE (AH)/1000 VOLTS AH kWh NO. OF BATTERIES TOTAL kWh 12 190 1000 2.28 16 36.48 CONCLUSIONS: 36.48 < 70 kWh SECTION 1206.2 DOES NOT APPLY TOTAL BATTERY WEIGHT (16 BATTERIES): 1,988.8 LBS TOTAL GALLONS - ELECTROLYTE & ACID (16 BATTERIES): 44.48 NORTHSTAR NSB 190FT RED BATTERY SPECS SCALE: NOT TO SCALE PROPOSED 1 /2" DIAMETER, SIMPSON STRONG -TIE STRONG -BOLT 2 WEDGE ANCHOR WITH 3-3/4" NOMINAL EMBEDMENT (ICC ESR-3037). TO BE INSTALLED A MINIMUM OF (1) IN EACH CORNER OF CABINET. SEE MANUFACTURER'S EQUIPMENT INSTALLATION MANUAL FOR ANCHOR LOCATIONS. IT IS ASSUMED THAT CABINET ANCHOR LOCATIONS HAVE BEEN DESIGNED/REINFORCED BY THE MANUFACTURER TO WITHSTAND SHEAR AND UPLIFT FORCES AS CALCULATED IN THIS DESIGN LOCK WASHER PLATE WASHER a a a a a a a a a Q EQUIPMENT BASE FRAME Z 10 V) i z U_ I— oO J N IT • • Mob ile• • •I 8960 ALDERWOOD ROAD PORTLAND, OR 97220 CROWN CC CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 Pm P. MARSHALL &ASSOCIATES 6801 PORTWEST DR., SUITE 100 HOUSTON, TX 77024 T-MOBILE SITE NUMBER: SE01626B BU #: 824070 ED LARGE / CARNELL MP 8505 BOWDOIN WAY EDMONDS, WA 98026 EXISTING 109'-2" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./ Q A 06/14/21 JAH PRELIMINARY HS 0 07/09/21 CS FINAL CD HS 1 08/30/21 PA FINAL REVISION HS 2 09/13/21 CS FINAL REVISION HS 3 10/11/21 CS JDX REVISION VT 4 12/02/21 CS JDX REVISION VT r WTTg-12/06/2021 UBI NUMBER: 604-106-184 RESUB Dec 10 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A JOB #: 21CCT7M-082 SHEET NUMBER: REVISION: CABINET ANCHOR DETAIL L SCALE: NOT TO SCALE MP Series ransfer Centers (U O)0tier?) Actual product may vary from photograph. Please request product drawings from solutions@intersectinc.com The MP Series consolidates AC service entrance power components into a single enclosure. Integrated components include mechanically interlocked main breakers enabling manual transfer between the utility and emergency power sources, Strikesorb° surge protection, Square D load center, and an optional Cam-Lok style generator receptacle. Space -saving Power Transfer Center is Versatile and Built for Long-lasting, Reliable Performance • Use as stand-alone service entrance panel or distribution sub -panel • Install on an H-frame or wall • Availabe with an optional pad mount or pad -lockable telco demar- cation box • Dead front switch board listed for 200 A, 10 or 30 • Standard designs for 100 and 200 amp applications; custom designs available for 60 amps to 200 amps Manual Transfer Switch • Mechanically interlocked — prevents the utility and generator sources from being closed at the same time • Main source "utility" breaker is rated 65 kAIC; alternate "generator" source breaker is rated 10 kAIC. Both breakers offer the "push -to -trip" red dot test feature • Transfer switch is constructed of 14-gauge steel Surge -Protected Loads from a 30- or 42-circuit Square D Panel Board • Strikesorb protection — Protection characteristics remain unchanged throughout service life — Loads are never left unprotected, as Strikesorb operates to a short circuit and trips main disconnect breaker in the event of a long duration, catastrophic over -voltage event • Load center accepts both bolt -on and plug-in branch circuit breakers NEMA 3R Enclosure • A stainless steel reinforced gasket "grips" the metal flange inside of the panel to provide a three-point seal for strengthened weatherproofing • Factory punched for ease of installation. Knockouts outline on back of panel simplify routing of power and grounding cables • Ships with UL-recognized plugs to maintain the enclosure's NEMA 3R rating For more information contact Intersect at solutions@intersectinc.com. ersect;lnc. Quality/products. Premium customer care. Integrated solutions. General Data Enclosure weight & dimensions Varies by service voltage, amperage and op- tions. Please request specific panel dimensions for the MP Series. Enclosure • NEMA 313 • 0.125" thick aluminum Powder coat paint UL Pantone (Cod Gray) TGIC polyester Door • 3-point latching system with 3-point seal • Pad -lockable UL certification • UL 50 — Enclosure for electrical equipment • UL 891 — Dead front switch boards • Service entrance rated Manufacturer's warranty Load Center Load center type Square D Circuit breaker positions 30 or 42 Circuit breaker type Square D — Bolt -on or plug-in branch devices Transfer Device Type Mechanical interlock Suppression Technology Technology type Strikesorb 40mm, 120 V modules (one per phase, L-N) UL certification UL 1449 3rd Edition Nominal operating voltage 120 V Suppressed voltage rating (SVR) UL 1449, Feb 2007 tested <500 V Maximum continuous operating voltage (MCOV) 150 V Let through voltage Ste, 7W ry o Reno 650 CM _ SSE in- rw Pes�hs 550-- 5 10 15 N _5 30 K 40 =45 5;7 55 G;;, .)5 T: -. Surge Current AmeraF (M) Available interrupt current (AIC) UL Recognized for direct installation behind any breaker in any circuit with an AIC rate of 85 kA rms without use of additional fusing. UL Recognized fore direct installation in any circuit having an available fault current up to 200,000 A rms, when protected by a 4000 A Class L fuse. Remote alarming Form "C" relay Multiple surge resilience 2,000 hits at 10 kA (8/20 ps) (Represents the ability to withstand multiple strikes with less than a 5% change in characteristics.) Long duration surge performance 250 hits at 500 A, 2 msec squared waveform (IEEE C62.11) All specifications subject to change without notice. Strikesorb" is a registered trademark of Raycap Corporation. O Intersect, Inc. 2003-2015. Rev 041515. TM' IntersectfInc. f X a P.O. Box 753 Liberty Lake WA 9901— USA Phone: 509.255.9570 or 800.910.3735 Fax:.509.255.6034 www.intersectinc.com IT • • Mob ile• • •I 8960 ALDERWOOD ROAD PORTLAND, OR 97220 (CROWNDZ CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 DI � P. MARSHALL &ASSOCIATES 6801 PORTWEST DR., SUITE 100 HOUSTON, TX 77024 T-MOBILE SITE NUMBER: SE01626B BU #: 824070 ED LARGE / CARNELL MP 8505 BOWDOIN WAY EDMONDS, WA 98026 EXISTING 109'-2" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 06/14/21 JAH PRELIMINARY HS 0 07/09/21 CS FINAL CD HS 1 08/30/21 PA FINAL REVISION HS 2 09/13/21 CS FINAL REVISION HS 3 10/11/21 CS JDX REVISION VT 4 12/02/21 CS JDX REVISION VT 55949 WTTV -12/06/2021 UBI NUMBER: 604-106-184 RESUB Dec 10 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A JOB #: 21CCT7M-082 SHEET NUMBER: REVISION: NTERSECT 200 AMP PPC W/ BUILT-IN CAM LOK BOX SCALE: NOT TO SCALE TO ANTENNA COAX COPPER/GALVANIZED GROUND BAR O O O IO O O O O O O O O O O O O O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O O O O O O O O O O O O O O 0 TWO HOLE LONG BARREL COMPRESSION LUG (TYP) NOTES: 1. DOUBLING UP "OR STACKING" OF CONNECTIONS IS NOT PERMITTED. 2. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 3. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO ANTENNA MOUNT STEEL. ANTENNA SECTOR GROUND BAR DETAIL SCALE: NOT TO SCALE TO TOWER MOUNTED EQUIPMENT (TYP) TO ANTENNA STANDARD COAX CABLE GROUND KIT (TYP) #6 STRANDED CU WIRE WITH GREEN, 600V, THWN INSULATION (OR AS PROVIDED WITH GROUND KIT) (TYP) MONOPOLE 4 r ANTENNA GROUND BAR LOCATED AT MCL I I (BONDED TO TOWER STEEL) 2 HOLE LUG (TYP) MECHANICAL CONNECTION (TYP) COAX GROUND BAR WITH COAX CABLE INSULATORS, CONNECTED (TYP FOR ALL) DIRECTLY TO THE BOTTOM OF MONOPOLE. SEE NOTE 1. TO BTS EQUIPMENT VIA 2/0 TINNED BARE TRAY OR ICE BRIDGE COPPER WIRE MONOPOLE PIER GROUND WIRE SEE NOTE 3 GROUND WIRE NOTE 3 - -- - �--�--�-ice INSPECTION WELL i EXOTHERMIC WELD (TYP) NOTES: I l . NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA LOCATIONS AND CONNECTION ORIENTATION. COAXIAL CABLES EXCEEDING 200 FEET ON THE TOWER SHALL HAVE GROUND KITS AT THE MIDPOINT. PROVIDE AS REQUIRED. 2. ONLY MECHANICAL CONNECTIONS ARE ALLOWED TO BE MADE TO CROWN CASTLE USA INC. TOWERS. ALL MECHANICAL CONNECTIONS SHALL BE TREATED WITH AN ANTI -OXIDANT COATING. 3. ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF THE RECOGNIZED EDITION OF ANSI/TIA 222 AND NFPA 780. TYPICAL ANTENNA CABLE GROUNDING SCALE: NOT TO SCALE TO ANTENNA COAX COPPER/GALVANIZED GROUND BAR 0 o O O O O O O O O O O O O 0' O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O TWO HOLE LONG BARREL COMPRESSION LUG (TYP) NOTES: #2 SOLID TINNED COPPER CONDUCTOR TO TOWER/SHELTER GROUND RING (2 TYP. FOR BOTTOM GROUND BAR ONLY) 1. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 2. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL (TOWER ONLY). 3. GROUND BAR SHALL BE ISOLATED FROM BUILDING OR SHELTER. TOWER/SHELTER GROUND BAR DETAIL SCALE: NOT TO SCALE 2-HOLE CRIMP/ COMPRESSION CONNECTOR STAINLESS STEEL BOLT FYP) STAINLESS STEEL FLAT WASHER (TYP) GROUND BAR STAINLESS STEEL FLAT WASHER STAINLESS STEEL (TYP) BELLVILLE WASHER STAINLESS STEEL NUT (TYP) (TYP) SINGLE CONNECTOR AT GROUND BARS DRAGOI 2-HOLE CRIMP/ COMPRESSION CONNECTOR BELLVILLE WASHER (TYP) SINGLE CONNECTOR AT STEEL OBJECTS 2-HOLE CRIMP/ COMPRESSION CONNECTOR STAINLESS STEEL SELF -DRILLING METAL SCREW (TYP) 8" PVC PLUG 8" PVC PLUG CPLG. (THIRD.) T/FINISH GRADE SUBGRADE Cq 0 0 #2 SOLID (TEST LOOP) z z NOTCH SIDES OF 8" PVC SCH 40 PIPE - C5 oM TO ALLOW EXIT/ENTRANCE OF 110 wp EXOTHERMIC WELD GROUND RING WIRE w Lu II III III I II III II II- 10 TRENCH BOTTOM CADWELD TEST LOOP TO GROUND RING WIRE NOTES: U 5/8" Q x 10'-0" LONG COPPER CLAD GROUND ROD 1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE VERTICAL 2. GROUND WIRE SHALL BE MIN. 30" BELOW GRADE OR 6" BELOW FROST LINE. (WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D) N STAINLESS STEEL BOLT �L_u O z STAINLESS STEEL z �I FLAT WASHER w 0 w w STEEL BLESS STEEL WASHER STAINLESS STEEL NUT TYP) STAINLESS STEEL FLAT WASHER (TYP) DRAGON TOOTH METALLIC OBJECT WASHER (TYP) SINGLE CONNECTOR AT METALLIC/STEEL OBJECTS HARDWARE DETAIL FOR EXTERIOR CONNECTIONS SCALE: NOT TO SCALE GRADE 2/0 TINNED CU EXTERNAL TOWER GROUND RING WIRE 3 INSPECTION WELL DETAIL SCALE: NOT TO SCALE 6" WIDE METALLIC HTEL WARNING/LOCATOR TAPE AT 12" DEPTH EXOTHERMIC WELD GROUND RING #2 COPPER WIRE SOLID, TINNED FOR CARRIER AND ICE BRIDGE GROUND LOOP GROUND RING 2/0 FOR TOWER GROUND LOOP GROUND ROD COPPER CLAD STEEL ROD W/MIN. 5/8 0 x I U-0" LONG NOTES: 1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE VERTICAL 2. GROUND WIRE SHALL BE MIN. 30" BELOW GRADE OR 6" BELOW FROST LINE. (WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D) GROUND ROD DETAIL 6 SCALE: NOT TO SCALE IT • • Mob ile• • •I 8960 ALDERWOOD ROAD PORTLAND, OR 97220 ccCROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 1DDj � P. MARSHALL &ASSOCIATES 6801 PORTWEST DR., SUITE 100 HOUSTON, TX 77024 T-MOBILE SITE NUMBER: SE01626B BU #: 824070 ED LARGE / CARNELL MP 8505 BOWDOIN WAY EDMONDS, WA 98026 EXISTING 109'-2" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 06/14/21 JAH PRELIMINARY ITS 0 07/09/21 CS FINAL CD HS 1 08/30/21 PA FINAL REVISION HS 2 09/13/21 CS FINAL REVISION HS 3 10/11/21 CS JDX REVISION VT 4 12/02/21 CS JDX REVISION VT WV-"-12/06/2021 UBI NUMBER: 604-106-184 RESUB Dec 10 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A JOB #: 21CCT7M-082 SHEET NUMBER: REVISION: G-2 4 WEATHERPROOFING KIT (SEE NOTE 3) ANTENNA CABLE #6 AWG STRANDED TO GROUND BAR). CABLE GROUND KI' CABLE CONNECTO. NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. CABLE GROUND KIT CONNECTION 'we TYPE 2-YA-2 TYPE XA TYPE GR TYPE VS TYPE VB TYPE PT TYPE GT2 NOTE: 1. ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH CONSTRUCTION MANAGER FOR SPECIFIC MOLDS TO BE USED FOR THIS PROJECT. 2. MOLD TYPE ONLY TO BE USED BELOW GRADE WHEN CONNECTING GROUND RING TO GROUND ROD. CADWELD GROUNDING CONNECTIONS SCALE: NOT TO SCALE (TYPICALLY) 1')" Tr) ')A" SCALE: NOT TO SCALE TO ANTENNAS COAX JUMPER (TYP.) CONNEC WEATHERPROOFIN( (TYP. SEE NO ANTENNA Cf TO BTS EQUIPMENT (- NOTES: WEATHERPROOFING KIT (TYP) GROUND KIT (TYP) �6 AWG COPPER/GALVANIZED COAX GROUND BAR BONDED DIRECTLY TOWER 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. 2. WEATHERPROOFING SHALL BE TWO-PART TAPE KIT. COLD SHRINK SHALL NOT BE USED. WIRE SIZE BURNDY LUG BOLT SIZE #6 AWG GREEN INSULATED YA6C-2TC38 3/8" - 16 NC S 2 BOLT #2 AWG SOLID TINNED YA3C-2TC38 3/8" - 16 NC S 2 BOLT #2 AWG STRANDED YA2C-2TC38 3/8" - 16 NC S 2 BOLT #2/0 AWG STRANDED YA26-2TC38 3/8" - 16 NC S 2 BOLT #4/0 AWG STRANDED YA28-2N 1 /2" - 16 NC S 2 BOLT BURNDY GROUND LUG W/ HEAT SHRINK LONG BARREL (SEE CHART) (CLEAR) NUT GROUNDING (TYP) CONDUCTOR LOCK WA(HER TYP) GROUND BAR BOLT (SEE CHART) (TYP) BURNDY TWO HOLE LUG W/ LONG BARREL SEE CHART) BARE WIRE TO BE NO-OX AT BOTH ENDS STRANDED (GREEN INSULATED) ONLY FOR #6 AWG (SEE CHART) NOTES: 1. ALL GROUNDING LUGS ARE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. ALL HARDWARE BOLTS, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL. ALL HARDWARE ARE TO BE AS FOLLOWS: BOLT, FLAT WASHER,GROUND BAR, GROUND LUG, FLAT WASHER AND NUT. MECHANICAL LUG CONNECTION SCALE: NOT TO SCALE #6 AWG MIN. FROM ANTENNA CABLE GROUND KIT GROUND BAR ON SHELTER. IC BRIDGE, OR ON ANTENNA TOWEI IT • • Mob ile• • •I 8960 ALDERWOOD ROAD PORTLAND, OR 97220 CCCROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 P 0 O P. MARSHALL & ASSOCIATES 6801 PORTWEST DR., SUITE 100 HOUSTON, TX 77024 T-MOBILE SITE NUMBER: SE01626B BU #: 824070 ED LARGE / CARNELL MP 8505 BOWDOIN WAY EDMONDS, WA 98026 EXISTING 109'-2" MONOPOLE] ISSUED FOR: REV DATE DRWN DESCRIPTION DES./ Q A 06/14/21 JAH PRELIMINARY HS 0 07/09/21 CS FINAL CD HS 1 08/30/21 PA FINAL REVISION HS 2 09/13/21 CS FINAL REVISION HS 3 10/11/21 CS JDX REVISION VT 4 12/02/21 CS JDX REVISION VT GROUND CABLE CONNECTION *TWO HOLE LUG, OR EXOTHERMIC GROUNDING SHALL BE ELIMINATED 3/8-1 lxl" TAMPER 4 SCALE: NOT TO SCALE WELD TO BE USED WITH #2 AWG BARE WHEN GROUND BAR IS ELECTRICALLY RESISTANT BOLT CONDUCTOR WIRE TO BUILDING BONDED TO METAL TOWER (TYP) SERVICE GROUND OR GROUND RING INSULATORS p,� WII�I01�1 SEE NOTE 2. og WAsu� (TYP) O� 0 WALL BRACKET ® GROUNDWIRE INSTALLATION (TYP) ® ® NOTE: MINIMUM OF S/S NUT 5 � 55949 � ® ® 3 THREADS TO BE (TYP) SCALE: NOT TO SCALE �'rsTEX'' ® VISIBLE ssIONAL� (TYP) 12/06/2021 ® S/S SPLIT UBI NUMBER: 604-106-184 WASHER ® ® TYP LONG HOLE 2 ® (TYP) #2 TINNED SOLID IN 3/4" LIQUID TIGHT CONDUIT PIPE RES U B ® ® UNIVERSAL COPPER BARREL TINNEDSOLID COPPER FROM 24" BELOW GRADE TO WITHIN 3" TO b" OF GROUND BAR (4"x20") LUG S/S FLAT CAD -WELD TERMINATION POINT. EXPOSED END Dec 10 2021 WASHER OF THE LIQUID TIGHT CONDUIT MUST BE SEALED CITY OFEDMONDS LOCK WASHER (TYP) (TYP) WITH SILICONE CAULK. DEVELOPMENTP SERVICES P/N M10 ENT (TYP) TWO -HOLE COMPRESSION LUG NOTES: 1. DOWN LEAD (HOME RUN) CONDUCTORS ARE NOT TO BE INSTALLED ON CROWN CASTLE USA INC. TOWER, PER THE GROUNDING DOWN CONDUCTOR POLICY QAS-STD-10091. NO MODIFICATION OR DRILLING TO TOWER STEEL IS ALLOWED IN ANY FORM OR FASHION, CAD -WELDING ON THE TOWER AND/OR IN THE AIR ARE NOT PERMITTED. 2. OMIT INSULATOR WHEN MOUNTING TO TOWER STEEL OR PLATFORM STEEL USE INSULATORS WHEN ATTACHING TO BUILDING OR SHELTERS. 6 GROUND BAR DETAIL SCALE: NOT TO SCALE TIN COATED SOLID CADWELD COPPER BUS BAR (TYP) S/S FLAT WASHER CHERRY INSULATOR (TYP) INSTALLED IF REQUIRED S/S BOLT (TYP) TIE INTO EXISTING GROUND RING 7 LUG DETAIL SCALE: NOT TO SCALE TRANSITIONING GROUND DETAIL SCALE: NOT TO SCALE IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A JOB #: 21CCT7M-082 SHEET NUMBER: REVISION: 11,..�G - 3 L 4