Loading...
REVIEWED RESUB 1-Structural_Analysis_or_Calculations+11.4.2021_10.57.53_AM+2502329REVIEWED BY CITY OF EDMONDS A AMERICAN TOWER C O R P O R A T I O N Eng.# 13696032_C2_02 October 15, 2021 Page 1 of 2 Structural Evaluation ATC Site 414383 Reviewed By: Number & Name Expires: 12/02/2021 SEAQ LAKE BALLINGER WA, WA Carrier Site Number 163036 WASE LAKE_BALLINGER & Name I�. L4 Site Location 24329 Highway 99 Edmonds, WA 98020, Snohomish County " �FWA5NING 47.7786 N / 122.3436 W l02 Tower Description 90 ft Monopole Basic Wind Speed 98 mph (3-second gust) Basic Wind w/ Ice 30 mph (3-second gust) w/1" radial ice concurrent � 7�Q� Applicable Code ANSI/TIA-222-H / 2018 IBC A,O , &- 4U RUCT� G� SSIONAV Evaluation Results: The loading in the tables below was evaluated with respect to the tower and foundation Authorized by "EOR" capacities. As future loading is added, or if actual loading is different from these tables, 18 Oct 2021 08:30:02 -0si, re-evaluation shall be required. This tower and foundation are adequate to support the below loads in conformance with specified requirements. Created By: Kyle MacPetrie Existing and Reserved Equipment Elev.1(ft) Qty Equipment Mount Type Lines Carrier 86.0 1 VZW Unused Reserve (21273.60 sqin) Square Platform with Handrails _ VERIZON WIRELESS 3 Nokia AirScale Dual RRH 4T4R B12/71 240W AH LOA 3 Nokia AHFIG 70.55 Ibs 73.0 2 Commscope HELIAX FiberFeed 12 RRU Pendant Connect Triangular Platform with Handrails (2) 1.55" (39.5mm) Hybrid (24) 7/8" Coax T-MOBILE 3 Andrew TMBXX-6516-A2M with actuator 3 Commscope FFVV-65C-R3-V1 3 Nokia AEHC 71.0 3 Andrew TMAT19211378-21A Equipment to be Removed Elev1(ft) Qty Equipment Mount Type Lines Carrier 90.0 1 Generic 24" x 24" Junction Box (1) 1 5/8" Hybriflex (6) 7/8" Coax VERIZON WIRELESS 89.0 3 Generic RRU (Model TBD) 88.0 6 Amphenol Antel W65-13-x010 86.0 3 Antel HTXC4517R000G ,n ATC Tower Services, Inc. 3500 Regency Parkway, Suite 100 - Cary, NC 27518 — 919-468-0112 Office — 919-466-5414 Fax - www.americantower.com Eng. 13696032_C2_02 AOctober 15, 2021 Page 2 of 2 AMERICAN TOWER C O R P D R A T 1 O N Proposed Equipment Elevl(ft) Qty Equipment Mount Type Lines Carrier 88.0 3 Ericsson Radio 4449 - B13&B5 Square Platform with Handrails (3) 1 5/8" Hybriflex VERIZON WIRELESS 3 Ericsson 8843 Rev 2 3 Raycap RCMDC-3315-PF-48 3 Ericsson AIR 6449 B77D/ C-Band 6 Commscope NHH-45A-R2B 'Contracted elevations are shown for appurtenances within contracted installation tolerances. Appurtenances outside of contract limits are shown at installed elevations. Install proposed lines inside the pole shaft. ATC Tower Services, Inc. 3500 Regency Parkway, Suite 100 - Cary, NC 27518 — 919-468-0112 Office — 919-466-5414 Fax - www.americantower.com