Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED BLD2021-1290+Interior_Lighting_Summary+9.17.2021_10.17.14_AM+2415249
LIGHTING COMPLIANCE SUMMARY _J 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2021 NEEA, All rights reserved Project Title Mike's Plumbing Tenant Improvement - 2018 WSEC For Building Department Us E C E I V E D Date: Sep 09, 2021 Project Address 21010 70th Ave West Project & Applicant Edmonds, WA 98026 Information Applicant Name Blake Bethards BLD2021-1290 Sep 17 2021 Applicant Phone 310-463-1013 CITY OF EDMONDS DEVELOPMENT SERVICES Applicant Email blake@bethardsarchitecture.com DEPARTMENT For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Office, Other Building Cond. Floor 2,771 Area Project Cond. Floor 2 771 Alteration New Building Alteration Area General Project Types Change in Space Conditioning (Semi -heated converted to Fully or Addition Lighting Interior Lighting Floors Above Grade 1 Compliance Method Compliance Method 1 - Conditioned) Lighting Scope g g P Scope General TENANT IMPROVEMENTS TO APPROXIMATELY 6,828 SF EXISTING BUILDING INCLUDING THE DEMOLITION OF PORTIONS OF THE EXISTING BUILDING INTERIOR, NEW WALL AND Lighting Project Description CEILING CONSTRUCTION, NEW LIGHT FIXTURE AND POWER & DATA INSTALLATION, NEW RESTROOM FACILITIES AND KITCHENETTE + ASSOCIATED PLUMBING, NEW MECHANICAL SYSTEM, REPLACEMENT AND REFURBISHMENT OF (E) EXTERIOR GARAGE DOORS AND WINDOWS, EXTERIOR FACADE IMPROVEMENTS AND NEW CARPET AND PAINT THROUGHOUT. ALL CONSTRUCTION IS NON-COMBUSTIBLE. Lighting Compliance Scope and Method Project a Type Interior / Exterior (Interior includes both interior & parking) Luminaire Replacement Scope p p Compliance Method p LPA Calculation Adjustment Compliance Verification p Alteration Interior Lighting 50% or more replaced Building area No Calculation Adjustments allowed COMPLIES Additional Efficiency Options Included Project Title Mike's Plumbing Tenant Improvement - 2018 WSEC Date Sep 09, A Lighting Power Calculation ALTERATION - INTERIOR LIGHTING (50% or more replaced) Compliance Verification COMPLIES Compliance Method Building area LPA Calculation Adjustment none Interior Lighting Power Allowance - Building Area Building Areas Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed Total Proposed Watts Compliance Status by (SF x LPA x 1) By Building Area Building Area Office 2,131 0.64 1,364 1,354 COMPLIES Warehouse 4,203 0.40 1,681 1,512 COMPLIES r Proposed Lighting Power Density Watts per Total Watts Fixture Type/Application Fixture ID Building Area New or Quantity of Fixtures, CLDs or Fixture, CLD or Total Linear Watts per Linear Proposed Existing -to -Remain Luminaires (#F) Luminaire (WpF) Feet (LF) Foot (WpLF) (#F x WpF) or (LF x WpLF) Individual Fixtures Horizontal surface -mount S1 Warehouse New 35 32 1,120 Recessed downlight R2 Office New 13 30 387 Recessed downlight RECESSED Office New 13 27 351 Suspended PI Warehouse New 4 98 392 Wall -mounted VANITY WALL MOUNT Office New 2 15 30 Linear Fixtures LED strip I RI I Office New 19 131 1 1 585 Project Title Mike's Plumbing Tenant Improvement - 2018 WSEC Date Sep 09, 2021 Proposed Fixtures Details ALTERATION - INTERIOR LIGHTING (50% or more replaced)ML h6 Fixture Type/Application Fixture ID Location in Documents Lamp Type Building Area New or Existing -to -Remain Individual Fixtures Horizontal surface -mount S 1 PLAN AI A LED Warehouse New Fixture Description: 4' SURFACE MOUNT LED Are these fixtures located within a daylight zone?: Yes, applying exception for controls Do these fixtures require specific application lighting controls?: None required Recessed downlight R2 A1.4 LED Office New Fixture Description: 2X2 RECESSED LED AT DROPPED T-GRID CEILING Are these fixtures located within a daylight zone?: Yes, applying exception for controls Do these fixtures require specific application lighting controls?: None required Recessed downlight RECESSED A1.4 LED Office New Fixture Description: 6" LED RECESSED DOWNLIGHT Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Suspended P1 A1.4 LED Warehouse New Fixture Description: HIGH -BAY LED PENDANT Are these fixtures located within a daylight zone?: Yes, applying exception for controls Do these fixtures require specific application lighting controls?: None required Wall -mounted VANITY WALL MOUNT A1.4 LED Office New Fixture Description: LED SURFACE WALL MOUNT Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Linear Fixtures LED strip R1 I PLAN A1.4 LED Office New How is linear fixture quantity defined?: Quantity of fixtures with current limiting device Length of track (LT): Fixture Description: RECESSED LINEAR LED STRIP AT DROPPED T-GRID CEILING Are these fixtures located within a daylight zone?: Yes, applying exception for controls Do these fixtures require specific application lighting controls?: None required