APPROVED BLD BLD2021-1341+Architectural_Plan+9.29.2021_11.20.40_AM+243507222050 99th Place West
Edmonds, WA 98020
Home Owners: Matthew Hart +
Bethany Childress
206-979-4315
childresshart@gmail.com
ChildressHart Home
September 27, 2021
PROPERTY INFORMATION
Property Address
22050 99TH PL W, EDMONDS, WA 98020-4540
Parcel Number
00602100100700
Property Description
TWIN VIEW ESTATES DIV 1
PROJECT DESCRIPTION
BLK 001 D-00 - LOT 7 BLK A
Primary Bath Remodel & Primary Bedroom Entry revised (closet
added & entry relocated), Miscellaneous Exterior Walls opened (wall
panel removed) for electrical rewire - insulation being replaced where
wall opened. Adding non-structural walls at Rec Room and in
Basement for an mud room / storage and den.
Please note mechanical and plumbing work is being performed under
separate permits, see permit numbers below:
BLD2021-0971 - Gas Piping
BLD2021-0972 - Plumbing for new hot water heater and multiple
fixture replacements
BLD2021-1278 - Master Bath Remodel (Plumbing Only)
BLD2021-1302 - Furnace Replacement (old furnace - heating oil, new
furnace - natural gas)
Other Work
Existing Oil Tank Removal
Permit for Oil Tank Removal under Fire Department =
FIR2021-078 — Work Completed and Inspected
Electrical Rewire
Permit for Electrical Rewire under LNI =
3619910E - Work Complete and Awaiting Final Inspection
PROJECT CONTACT
Matthew Hart
CHI LDRESSHART(o-)-GMAI L.COM
206-979-4315
Updates:
September 29, 2021 - Added information about Smoke
Detectors and Carbon Monoxide Detectors to plans.
Space in basement labeled "open" revised to say gym.
APPROVED
PLANS MUST BE
ON JOB SITE
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
City Of Edmonds
Building Department
Work INTERIOR REMODEL
Address 22050 99TH PL W
Owner HART
----------------------------------
---------------------------------
Approved Date 10/14/2021
Building Official ; W. X
---------------------------------------------------------
Permit Number: BLD2021-1341
RECEIVED
Sep 30 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Page - 1 of 6
.�''''', I t#** ♦j
•
'Existing
=Rec Room
•
23' x 19,5'
445 sf
40
• 0
5'-0"
Existing
Hall
60'
Existing
Garage
23' x 23'
530 sf
Page -2of6
Level 1: Existing Plan
-Repair, infill sub floor
Non-structural wall removed. adjacent
hallway wall to be extended
existing
closet
Existing
Bedroom
11' x 11'
120 sf
existing
closet
o Existing
°' Hall
Existing
Bedroom
9,5' x 11'
100 sf
existing
closet
existing
closet
— T-0"
xlst
Hall
36'
L
(xisting
Closet
7' x 15'
110 Sf
Existing
ih Hall
O
Existing
Bath
7 x 7
J 45 sf
existing
closet
■
Existing
Living Room
16' x 19'
300 sf
Refer to photograph set A on page 6 for
additional information
1■
Existing
Kitchen
9' x 15.5'
140 sf
Existing
Dining
7.5' x 8'
60 sf
Existing
Closet
4' x 7.5'
30 sf
Existi
B h
5' x 14'
110 sf
0
Existing
Shower
3-.5' x 4.5'
15 s�
Existing
Breakfast
6' x 7'
40 sf
Existing
Deck
M
scale = 114"
Remove low/partial wall
Remove tub
Existing
Bedroom
17' x 23,5'
400 sf
Refer to photograph set C on page 6 fo
additional information
Repair damaged wall
-Remove shower
Existing to be removed or
repaired
RECEIVED
Sep 30 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
22050 99th Place West
Edmonds, WA 98020
Home Owners: Matthew Hart +
Bethany Childress
September 27 2021 North 206-979-
4315
Se p , childresshartart@gmail.com
Add door to bedroom
Add non-structural walls for closet
scale = 114"
Repair/infill sub floor
Smaller
Rec Room
15' x 19.5'
- . 290 sf
Add non-struct
wall
New
Entry
7.5' x 19.5'
245 sf
5'-0"
Existing
Hall
Existing
Garage
23' x 23'
530 sf
Page -3of6
Level 1: New Plan
M
existing
closet
Existing
Bedroom
11' x 11'
120 sf
existing
closet
o Existing
"' Hall
Existing
Bedroom
9.5' x 11'
100 sf
Existing
Closet
4' x 7,5'
e w 30 sf
/set
Non-structural w ' I =
New Non-structural wall infill + dM or S Existing
Hall Bedroom
17' x 23.5'
400 sf
Add partial height furring wall
New New tub
Laundry WAD
3.5' x 8.5' L�'
30 sf Existing Convert tub to tile shower
Bath
0 8.5' x 14' (add non-structural wing walls)
existing O 110 sf
closet C
O CDO Add non-structural furring wall to align
O Existing
Bath with existing
7' x 7'
45 sf
2-1
existing ,elocatec
closet t
R-15 batt insulation to be installed at
S x 4.
15 f location where exterior wall is opened for
existing 15 s
CIO
O plumbing / electrical work
— T-0"
xlst
Hall
L
Existing
Kitchen
9' x 15.5'
140 sf
Existing
Breakfast
6' x 7'
40 sf
Repair water damaged wall, add door
Relocate toilet
S *Smoke Detector
Existing
Dining
760 sf8" S� *Smoke Detector /
Carbon Monoxide Combo
Existing New R-15 batt
Deck i insulation locations
Existing
Living Room New walls / doors
16' x 19'
300 sf
Notes
*All smoke detectors and smoke
/ carbon monoxide detectors
were installed in July 2021 and
inspected by L&I. The detectors
are all wired together.
RECEIVED 22050 99th Place West
Sep 30 2021 Edmonds, WA 98020 _
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Home Owners: Matthew Hart +
Bethany Childress
September 27 2021 North 206-979-
4315
Se p , childresshartart@gmail.com
scale = 114"
Existing paneling removed
for repair (electrical re -wire)
Page - 4 of 6
Basement: Existing Plan
noved or
:D
ES
��....,..,.,......�ce West
Edmonds, WA 98020
Home Owners: Matthew Hart +
Bethany Childress
September 27 2021 North 206-979-
4315
Se p , childresshartart@gmail.com
scale = 114"
R-15 batt insulation to be
installed at location where
exterior wall is opened for
plumbing / electrical work
Page -5of6
Basement: New Plan
Sep 30 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Combo
is
-s and smoke
detectors
ly 2021 and
he detectors
er.
��.,..,..,.,......�ce West
Edmonds, WA 98020
Home Owners: Matthew Hart +
Bethany Childress
September 27, 2021 North I
206-979-4315
childresshart@gmail.com
*Photograph Set A
Existing Hallway Wall
Location of removed wall
Photograph Set B
Photograph Set C
Page -6of6
Supplemental Information
r=vic+inn I- n11Xni0Xi \Noll
Location of removed wall
Location of removed wall
- wall not attached to any joists
- wall runs parallel to joist
- top plate running below 1 x4
that is used for ceiling finish
rea of wall to be removed
krea of wall to be remain
Water damage discovered
during shower removal. wall to
be repaired / replaced.
Existing Hallway Wall
w
Location of removed wall
- wall not attached to any joists
- wall runs parallel to joist
2x4 in photograph added for
patching ceiling
Location of removed wall
- wall not attached to any joists
- wall runs parallel to joist
- top plate running below 1x4
that is used for ceiling finish
Floor Joist
Floor Joist
RECEIVED
Sep 30 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
SeDtember 27. 2021
Location of removed wall
- wall not attached to any joists
- wall runs parallel to joist
Notes
*Blown -in Insulation (R-49) to
be installed in the attic after
work above ceiling is
complete.
22050 99th Place West
Edmonds, WA 98020
Home Owners: Matthew Hart +
Bethany Childress
206-979-4315
childresshart@gmail.com