Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED BLD2021-1359+Interior_Lighting_Summary+10.4.2021_10.14.01_AM+2442439
LIGHTING COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2021 NEEA, All rights reserved Project &Applicant Information Project Title 5th Ave Cleaners N Tailors Inc - 2018 WSEC For Building Department Use: REVIEWED BY CITY OF EDMONDS Date: Oct 01, 2021 RECEIVED Oct 05 2021 ONDS CILOPMTY OF ET ERVI DEVELOPMENT SERVICES DEPARTMENT Project Address S5th Ave S. Edmonds, ds, WA98020 Applicant Name Blake Bethards Applicant Phone 310-463-1013 Applicant Email blake@bethardsarchitecture.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Services, Laundry/Dry Cleaning Building Cond. Floor Area 1,228 General Project Types Alteration New Building or Addition Lighting Scope Alteration Lighting Scope Interior Lighting Project Cond. Floor Area 1,228 Floors Above Grade 1 Compliance Method Not Selected Lighting Project Description TENANT OPERATES A FULL -SERVICE DROP-OFF WASH AND FOLD LAUNDRY SERVICE Lighting Compliance Scope Project a Pro Interior / Exterior (Interior includes both interior & parking) Luminaire Replacement Scope Compliance Method LPA Calculation Adjustment Compliance Verification and Method Alteration Interior Lighting 50% or more replaced Building area No Calculation Adjustments allowed COMPLIES Additional Efficiency Options Included Project Title I 5th Ave Cleaners N Tailors Inc - 2018 WSEC Date Oct 01, 2021 Lighting Power Calculation ALTERATION - INTERIOR LIGHTING (50% or more replaced) Compliance Verification COMPLIES Compliance Method Building area LPA Calculation Adjustment none Interior Lighting Power Allowance - Building Area Building Areas Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed Total Proposed Watts Compliance Status by (SF x LPA x 1) By Building Area Building Area Retail 1,228 1 0.84 1,032 987 COMPLIES Proposed Lighting Power Density Watts per Total Watts Fixture Type/Application Fixture ID Building Area New or Quantity of Fixtures, CLDs or Fixture, CLD or Total Linear Watts per Linear Proposed Existing -to -Remain Luminaires (#F) Luminaire (WpF) Feet (LF) Foot (WpLF) (#F x WpF) or I LF x WpLF) Individual Fixtures Horizontal surface -mount S1 Retail Existing 3 40 120 Recessed downlight R2 Retail New 6 28 168 Recessed downlight RI Retail New 13 48 624 Recessed downlight R3 Retail New 5 13 65 Wall -mounted S2 Retail Existing 1 10 10 Project Title 5th Ave Cleaners N Tailors Inc - 2018 WSEC Date Oct 01, 2( Proposed Fixtures Details ALTERATION - INTERIOR LIGHTING (50% or more replaced) Fixture Type/Application Fixture ID Location in Documents Lamp Type Building Area New or Existing -to -Remain Individual Fixtures Horizontal surface -mount S1 2/A1.1 T-5 Fluorescent Retail Existing Fixture Description: Exist. 4' surface mounted fluorescent fixture Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: Display/accent lighting, occupancy controls Recessed downlight R2 2/Al.l LED Retail New Fixture Description: 2x2 Recessed LED Are these fixtures located within a daylight zone?: Yes, applying exception for controls Do these fixtures require specific application lighting controls?: None required Recessed downlight RI 2/Al.l LED Retail New Fixture Description: 2x4 Recessed LED Are these fixtures located within a daylight zone?: Yes, applying exception for controls Do these fixtures require specific application lighting controls?: None required Recessed downlight R3 2/Al.l LED Retail New Fixture Description: Recessed 6" LED Are these fixtures located within a daylight zone?: Yes, controls provided Do these fixtures require specific application lighting controls?: Display/accent lighting, occupancy controls Wall -mounted S2 ALI Compact Fluorescent Retail Existing Fixture Description: Existing Wall Mounted Fluorescent Fixture @ Restroom Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required