Loading...
REVIEWED FIR 2021-0124+Calculations+11.9.2021_6.48.41_PM+2512052ENGINEERS : GLOBAL MECHANICAL 686-841-0300. ADDRESS : Av Del Rio 3497, Fracc. Hacienda del Rio, Mexicali B.C. LICENSE : 1992254 DESIGNER : BAJA DESIGN ENGINEERING DATE : 11-08-2021 FILE : GENEL JOB NAME : GENEL HOUSE LOCATION : GENEL 7615 201 ST SW, EDMONDS, WA DESIGN DATA. HAZARD : DENSITY : AREA PER SPRINKLER : TOTAL CALCULATED AREA : TOTAL SPRINKLERS CALCULATED FLOW DATA. TOTAL SPRINKLER FLOW : TOTAL HOSE STREAM : TOTAL WATER REQUIRED : BASE OF RISER NODE: FLOW AUTHORITY HAVING JURISDICTION PHONE 0.05 GPM/FT2 THE 2 MOST HYDRAULIC REMOTE SPRINKI .054 Sq Ft 256 Sq Ft 512 Sq Ft 2 Heads 27.8 Gpm .0 Gpm 27.8 Gpm .0 Gpm PRESSURE 0 Psi HYDRONICS: FIRE SPRINKLER HYDRAULICS 5.4 - SUBMITTAL. Page 1 ENGINEERS : GLOBAL MECHANICAL 686-841-0300. ADDRESS : Av Del Rio 3497, Fracc. Hacienda del Rio, Mexicali B.C. Date: 11-08-2021 File: C:\Documents and Settings\Calculos\2021\WA-GENEL\GENEL.HYI JOB : GENEL HOUSE PUMP I STATIC : 70 Psi RESIDUAL : 25 Psi FLOW : 35 Gpm PUMP RATED 1 70 Psi at 35 Gpm NODE ELEVATION K- PRESSURE DISCHARGE NO. Feet FACTOR Psi Gpm ----------------------------------------------------------- S1 10.0 4.9 8.0 13.9 S2 10.0 4.9 8.1 13.9 C1 10.0 9.7 C2 10.0 8.5 C3 10.0 8.2 TR 10.0 11.9 AG .8 17.5 UG -3.0 21.6 UG1 -3.0 22.6 UG2 -3.0 SOURCE 22.6 27.8 SPRINKLERS FLOWING 2 Heads AREA PER SPRINKLER 256 Sq Ft REQUIRED DENSITY .05 Gpm/Sq Ft COMPUTED DENSITY .05 Gpm/Sq Ft TOTAL SPRINKLER FLOW 27.8 Gpm INSIDE HOSE STREAM Gpm OUTSIDE HOSE STREAM Gpm TOTAL WATER REQUIRED 27.8 Gpm TOTAL SPRINKLER PRESS 22.6 Psi VALVE FIXED LOSS Psi Copyright (2005) SUPPLY PRESS AVAILABLE 40.4 Psi by DEMAND PRESS REQUIRED 22.6 Psi Hydronics Engineering PRESSURE CUSHION 17.7 Psi 34119 Fremont Bl, Suite 609 Fremont, Ca., 94555 MAXIMUM VELOCITY 9.2 F/S (800) 845-9819 HYDRONICS: FIRE SPRINKLER HYDRAULICS 5.4 - SUBMITTAL. Page 2 ENGINEERS : GLOBAL MECHANICAL 686-841-0300. ADDRESS : Av Del Rio 3497, Fracc. Hacienda del Rio, Mexicali B.C. Date: 11-08-2021 File: C:\Documents and Settings\Calculos\2021\WA-GENEL\GENEL.HYI JOB : GENEL HOUSE PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) ------------------------------------------------------------------------------- S1 q= 13.9 K= 4.9 L= 16.0 Pt 8.0 Pt 8.0 1 Q= 3.8 F= F= .0 C= 150 Pe .0 Pv .0 Vel= 1.3 D= 1.109 TL= 16.0 .0031 Pf .0 Pn 8.0 S2 Pt 8.1 -------------------------------------------------------------------------- S2 q= 13.9 K= 4.9 L= 9.0 Pt 8.1 Pt 8.1 2 Q= 12.1 F= 2T F= 10.0 C= 150 Pe .0 Pv -.1 Vel= 4.0 D= 1.109 TL= 19.0 .0261 Pf .5 Pn 7.9 C2 Pt 8.5 -------------------------------------------------------------------------- S1 q= 13.9 K= 4.9 L= 67.0 Pt 8.0 Pt 8.0 3 Q= 10.0 F= 3ET F= 26.0 C= 150 Pe .0 Pv -.1 Vel= 3.3 D= 1.109 TL= 93.0 .0183 Pf 1.7 Pn 7.9 Cl Pt 9.7 -------------------------------------------------------------------------- S2 q= 13.9 K= 4.9 L= 21.0 Pt 8.1 Pt 8.1 4 Q= 5.6 F= 2T F= 10.0 C= 150 Pe .0 Pv .0 Vel= 1.9 D= 1.109 TL= 31.0 .0062 Pf .2 Pn 8.0 C3 Pt 8.2 -------------------------------------------------------------------------- C1 q= .0 K= .0 L= 12.0 Pt 9.7 Pt 9.7 5 Q= 17.7 F= 2T F= 10.0 C= 150 Pe .0 Pv -.2 Vel= 5.9 D= 1.109 TL= 22.0 .0526 Pf 1.2 Pn 9.5 C2 Pt 8.5 -------------------------------------------------------------------------- C2 q= .0 K= .0 L= 30.0 Pt 8.5 Pt 8.5 6 Q= 5.6 F= 2ET F= 19.0 C= 150 Pe .0 Pv .0 Vel= 1.9 D= 1.109 TL= 49.0 .0062 Pf .3 Pn 8.5 C3 Pt 8.2 -------------------------------------------------------------------------- C1 q= .0 K= .0 L= 6.0 Pt 9.7 Pt 9.7 5 Q= 27.8 F= TE F= 12.0 C= 150 Pe .0 Pv -.6 Vel= 9.2 D= 1.109 TL= 18.0 .1205 Pf 2.2 Pn 9.1 TR Pt 11.9 -------------------------------------------------------------------------- TR q= .0 K= .0 L= 8.2 Pt 11.9 Pt 11.9 6 Q= 27.8 F= CG F= 5.0 C= 150 Pe 4.0 Pv -.6 Vel= 9.2 D= 1.109 TL= 13.2 .1205 Pf 1.6 Pn 11.3 AG Pt 17.5 -------------------------------------------------------------------------- AG q= .0 K= .0 L= 3.8 Pt 17.5 Pt 17.5 7 Q= 27.8 F= 17 F= 17.0 C= 150 Pe 1.6 Pv -.6 Vel= 9.2 D= 1.109 TL= 20.8 .1205 Pf 2.5 Pn 16.9 UG Pt 21.6 HYDRONICS: FIRE SPRINKLER HYDRAULICS 5.4 - SUBMITTAL. Page 3 ENGINEERS : GLOBAL MECHANICAL 686-841-0300. ADDRESS : Av Del Rio 3497, Fracc. Hacienda del Rio, Mexicali B.C. Date: 11-08-2021 File: C:\Documents and Settings\Calculos\2021\WA-GENEL\GENEL.HYI JOB : GENEL HOUSE PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) ------------------------------------------------------------------------------- UG q= .0 K= .0 L= 35.0 Pt 21.6 Pt 21.6 8 Q= 27.8 F= 13 F= 13.0 C= 150 Pe .0 Pv -.1 Vel= 4.4 D= 1.602 TL= 48.0 .0201 Pf 1.0 Pn 21.5 UG1 Pt 22.6 -------------------------------------------------------------------------- UG1 q= .0 K= .0 L= 50.0 Pt 22.6 Pt 22.6 9 Q= 27.8 F= F= .0 C- 140 Pe .0 Pv .0 Vel= .3 D= 6.4 TL= 50.0 .0 Pf .0 Pn 22.6 -------------------------------------------------------------------------- UG2 Pt 22.6 -------------------------------------------------------------------------- -------------------------------------------------------------------------- Q= 27.8 <<< SOURCE >>> Pt 22.6 E=>90-Elb T=>TeeBch L=>Lt-Elb C=>ChkVly B=>BfyVly G=>GatVly A=>AlmChk HYDRONICS: FIRE SPRINKLER HYDRAULICS 5.0 - SUBMITTAL. ENGINEERS : GLOBAL MECHANICAL 686-841-0300. ADDRESS : Av Del Rio 3497, Fracc. Hacienda del Rio, Mexicali B.C. DATE : 11-08-2021 FILE C:\Documents and Settings\Calculos\2021\WA-GENEL\G JOB : GENEL HOUSE PSI 100 90 80 70 60 50 40 30 20 10 0 FIRE SPRINKLER HYDRAULIC GRAPH 200 300 400 500 600 700 800 900 1000 FLOW - Gpm 0 o Supply Curve Static: 70.0 Resid : 24.5 Flow : 35.0 Source Pump Rated 70 Psi @ 35 Gpm Copyright: Hydronics Engineering, 2006. 34119 Fremont Bl, Suite 609, Fremont, CA. 94555. (800) 845-9819. • Demand Curve Avl Pr : 40.4 @ 28 Req Pr : 22.6 @ 28 Pr Cush: 17.7