Loading...
APPROVED BLD BLD2021-1510+Architectural_Plan+11.4.2021_12.26.05_PM+2502742La out Page Table Label Title 1 SUMMARY 2 PROPOSED/EXISTING FLOOR PLAN 3 1ST FLOOR CEILING FRAMING EXISTING / PROPOSED 4 FLOOR FRAMING / FOUNDATION 5 3D RENDERINGS S1.0 GENERAL STRUCTURAL NOTES S1.1 MAIN FLOOR & FOUNDATION PLAN S1.2 2ND FLOOR FRAMING PLAN S1.3 ROOF FRAMING PLAN S3.0 STRUCTURAL DETAILS REVISIONS Number Date Revised By Description OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE NO PLUMBING PERMIT HAS BEEN APPLIED AND OR ISSUED FOR THIS PROJECT. SHOULD PLUMBING WORK BE PART OF THIS PROJECT A PLUMBING PERMIT WILL BE REQUIRED City Of Edmonds Building Department ------------- Work INTERIOR REMODEL ------------------- Address: ------------------------ 9024 191 ST PL SW ------------------ ------------------ Owner ----------------- - --------------- NICHOLS/ZANIS Approved Date 11 /18/2021 Building Official : W. W pfia.sc Permit Number BLD2021-1510 3D VIEWS ARE NOT TO SCALE AND MAY NOT REFLECT EXACTLY WHAT IS AVAILABLE FOR THE PROJECT. RENDER VIEWS ARE REPRESENTATIONS OF WHAT THE VIEW COULD LOOK LIKE, NOT WHAT IT WILL LOOK LIKE. 2D VIEWS ALWAYS SUPERCEDE 3D VIEWS V p N N N 0 o — O U) O 0 O o > Q �j o -U co o0 Nt n' W O O 6 M O ( N O r Nt LICENSE NUMBER: HOMERSL941 BT U) Z Q N Z J W Q _ U C G (n J Cfl � O Q Lu z O a J J 06 (/) W U w 2 LU J O U �p No Q Z 0')� W J Q Q U) W H W Z Z w J O 2 U d w J H i= 75 G w Q C G a U) RECEIVED Nov 04 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DRAWN BY: JT DATE: 11 /4/2021 SCALE: 1 /4"= 1 'off SHEET #: 1 I I I I I I I I I- - - - - - - - - - - - - ATH / m--L— 5TAI RNELL / / 0 FAMILY OFFIG NO IL05ET UP / KITGHEN �II II tMEGHANGL05ET I I i I I ' II I1 L- II LIVING 15T FLOOR EXI5TING/PROP05ED FLOOR PLAN DINING ------------------- E11ZZ= (E) WALL TO BE REMOVED NO PLUMBING PERMIT HAS BEEN APPLIED AND OR ISSUED FOR THIS PROJECT. SHOULD PLUMBING WORK BE PART OF THIS PROJECT A PLUMBING PERMIT WILL BE REQUIRED sD \ L — — — J �1J I \ I \ J BEDRO\O\M REVISIONS Number Date Revised B Description --------------------------- uP � 2ND STORY EXI5TING FLOOR PLAN (NO CHANGE) �(E) MGG TRUSSES 3D VIEWS ARE NOT TO SCALE AND MAY NOT REFLECT EXACTLY WHAT IS AVAILABLE FOR THE PROJECT. RENDER VIEWS ARE REPRESENTATIONS OF WHAT THE VIEW COULD LOOK LIKE, NOT WHAT IT WILL LOOK LIKE. 2D VIEWS ALWAYS SUPERCEDE 3D VIEWS O N j a� N �--� N 0 o 4- 0 () O 0 2 0 L O i -U co co 0 O O M E O c N 0 r � Z LICENSE NUMBER: HOMERSL941 BT U7 Z Q N O z J J J W Q U _ C/ J ~ CD Q > V) z a J U W 2o LU J 0 U No 0 0 � Z m0 W J Q a c/) w I- 6 i z z w J O 2 U a_ V Z 7 LJ.I J I ^� 1 H ~ 0 ^' W a w0 a U)0 0 J � L.L EIVED ov 04 2021 Y OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DRAWN BY: JT DATE: 11 /4/2021 SCALE: 1 /4" = 1 ' 0" SHEET #: 2 REVISIONS 3D VIEWS ARE NOT TO SCALE AND MAY NOT Number Date Revised By-- Description REFLECT EXACTLY WHAT IS AVAILABLE FOR THE PROJECT. RENDER VIEWS ARE REPRESENTATIONS OF WHAT THE VIEW COULD LOOK LIKE, NOT WHAT IT WILL LOOK LIKE. 2D VIEWS ALWAYS SUPERCEDE 3D VIEWS L I I II I II II � II uP I \ � N v) CD 0 ------------ -0M _ m E II (E) 11 1/6" X 1 1/2" TJI @ 16" OG / I-T- U co II II = U co Nt II o M o L,7 II � cfl N m � � (E) YIIALL TO BE REMOVED "? r 0 (E) 11 l/8" X 1 7/6" LVL (E) 11 l/8" X 1 1/2" TJI (E) WALL TO BE REMOVED @16" OG HUNG OFF LICENSE NUMBER: (E) LVL cv i- HOMERSL941 BT y IL UP II V \ Z� Z w w UU)rwn J �+ ) (N) POST AND P05T/BEAM CONNECTION PER STRUCTURAL H W 0 H W a O� a 0 z 0 c J cn (N) DROPPED BEAM PER 5TRUGTURAL VJ r LL v m DRAWN BY: LLI—L -1L L I.. Lud �l �l .1 �l �l �l �l JT F) POST AND P05T/BEAM CONNECTION PER STRUCTURAL DATE: 11 /4/2021 SCALE: RECEIVED 1 /4" = 1' 0" Nov 04 2021 CITY OF EDMONDS SHEET #: DEVELOPMENT SERVICES DEPARTMENT 3 Z Q N Z J J W Q _ U C G p� � (n J � � � � Q z O a J w � � J 0 U � � o� � Q Z W J Q Q W H W Z Z � W J O 2 U d REVISIONS 3D VIEWS ARE NOT TO SCALE AND MAY NOT Number Date Revised B Description REFLECT EXACTLY WHAT IS AVAILABLE FOR THE PROJECT. RENDER VIEWS ARE REPRESENTATIONS OF WHAT THE VIEW COULD LOOK LIKE, NOT WHAT IT WILL LOOK LIKE. 2D VIEWS ALWAYS SUPERCEDE 3D VIEWS V O N j N 0 N o �--� }, () O 2 O o 0 > O � L O i (E) 2X10 FLOOR J0I5T5 16" OG — U coC — ao G � CN O o — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — O co �— ------ :..... -.� ( N II I I LICENSE NUMBER: (E)4 Xb BEAM HOMERSL941 BT lu Q U) ®i- �. - -• C 02 • • - Fir _-- - A ME Tm P - _ r r PqL- pr a 3D VIEWS ARE NOT TO SCALE AND MAY NOT REFLECT EXACTLY WHAT IS AVAILABLE FOR THE PROJECT. RENDER VIEWS ARE REPRESENTATIONS OF WHAT THE VIEW COULD LOOK LIKE, NOT WHAT IT WILL LOOK LIKE. 2D VIEWS ALWAYS SUPERCEDE 3D VIEWS V 0 N N N 0 o O () O 0 o > Q (D �j o -U co C G _ co � Nt ^ , W CDN CDM O co N O r Nt LICENSE NUMBER: HOMERSL941 BT U) z Q N Z J W Q _ U C G � (n J Cfl 00 d Q z O a J J 06 (/) W U w 2 LU J 0 U �p No 0 Z 0')� LIJ J Q Q U) W H W Z Z w J O 2 U d �v, V Z J W F- W Q Q Z a Nw RECEIVED Nov 04 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DRAWN BY: JT DATE: 11 /4/2021 SCALE: 1 /4" = 1 ' 0" SHEET #: 5 CRITERIA 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, THE 2018 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC) 3. DESIGN LOADING CRITERIA FLOOR LIVE LOAD 40 PSF 4. LATERAL LOADS ARE TRANSFERRED BY THE ROOF AND FLOOR DIAPHRAGMS TO THE SHEAR WALLS. FORCES ARE BASED ON THE TRIBUTARY AREA FOR EACH SHEAR WALL AND ARE CARRIED BY THE SHEAR WALLS TO THE FOUNDATION. 5. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 6. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. 7. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. 8. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THEIR WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES OF THE OWNER, CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. 9. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. 10. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. WHERE INFORMATION ON THE DRAWINGS IS IN CONFLICT WITH THE SPECIFICATIONS, THE MORE STRINGENT SHALL APPLY, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. DO NOT SCALE THE DRAWINGS. 11. ALL STRUCTURAL SYSTEMS WHICH ARE COMPOSED OF FIELD ERECTED COMPONENTS SHALL BE SUPERVISED BY THE SUPPLIER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE AND ERECTION IN ACCORDANCE WITH INSTRUCTIONS PREPARED BY THE SUPPLIER. 12. SHOP DRAWINGS STRUCTURAL STEEL AND CONNECTOR PLATE WOOD ROOF TRUSSES SHALL BE SUBMITTED TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION OF THESE ITEMS. 13. SHOP DRAWING REVIEW: DIMENSIONS AND QUANTITIES ARE NOT REVIEWED BY THE ENGINEER OF RECORD, AND THEREFORE MUST BE VERIFIED BY THE CONTRACTOR. CONTRACTOR SHALL REVIEW AND STAMP DRAWINGS PRIOR TO REVIEW BY ENGINEER OF RECORD. CONTRACTOR SHALL REVIEW DRAWINGS FOR CONFORMANCE WITH THE MEANS, METHODS, TECHNIQUES, SEQUENCES AND OPERATIONS OF CONSTRUCTION, AND ALL SAFETY PRECAUTIONS AND PROGRAMS INCIDENTAL THERETO. A MINIMUM OF TWO WEEKS SHALL BE ALLOWED FOR REVIEW. GEOTECHNICAL 14. FOUNDATION NOTES: ALLOWABLE SOIL PRESSURE AND LATERAL EARTH PRESSURE ARE ASSUMED AND THEREFORE MUST BE VERIFIED IN THE FIELD. IF SOILS ARE FOUND TO BE OTHER THAN ASSUMED, NOTIFY THE STRUCTURAL ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH (CONTROLLED, COMPACTED STRUCTURAL FILL OR BOTH) AT LEAST 18" BELOW LOWEST ADJACENT FINISHED GRADE. FOOTING DEPTHS/ELEVATIONS SHOWN ON PLANS (OR IN DETAILS) ARE MINIMUM AND FOR GUIDANCE ONLY; THE ACTUAL ELEVATIONS OF FOOTINGS MUST BE ESTABLISHED BY THE CONTRACTOR IN THE FIELD. UNLESS OTHERWISE NOTED, FOOTINGS SHALL BE CENTERED UNDER COLUMNS OR WALLS ABOVE. BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE. THE STRUCTURAL DESIGN IS BASED ON THE FOLLOWING ASSUMED VALUES: ALLOWABLE SOIL PRESSURE 1,500 PSF LATERAL EARTH PRESSURE (RESTRAINED/UNRESTRAINED) 55 PCF/35 PCF SEISMIC SURCHARGE PRESSURE (RESTRAINED/UNRESTRAINED) 8H PSF/5H PSF PASSIVE SOIL PRESSURE 350 PCF SOIL COEFFICIENT OF FRICTION 0.35 SOIL DENSITY 120 PCF GENERAL STRUCTURAL NOTES (The following apply unless shown otherwise on the plans) RENOVATION 15. DEMOLITION: VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. 16. CHECK FOR DRYROT AT ALL EXTERIOR WALLS, EXISTING TOILET ROOM FLOORS AND WALLS, AREAS SHOWING WATER STAINS, AND ALL WOOD MEMBERS IN BASEMENT AND CRAWL SPACES. ALL ROT SHALL BE REMOVED AND DAMAGED MEMBERS SHALL BE REPLACED OR REPAIRED AS DIRECTED BY THE STRUCTURAL ENGINEER OR ARCHITECT. 17. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH ACI 301. CONSTRUCTION TOLERANCES SHALL NOT EXCEED THOSE LISTED IN ACI 117. STRENGTHS AT 28 DAYS AND MIX CRITERIA SHALL BE AS FOLLOWS: TYPE OF CONSTRUCTION A. FOOTINGS, SLABS -ON -GRADE, TOPPING SLABS 28 DAY MAXIMUM STRENGTH (fc) SLUMP 2,500 PSI 5" MIN. CEMENT CONTENT MAX. PER CUBIC YARD AGGREGATE SIZE 5-1/2 SACKS 1 1 /4" MIXES SHALL BE PROPORTIONED SO AS NOT TO EXCEED THE MAXIMUM SLUMPS INDICATED (BEFORE THE ADDITION OF ADMIXTURES). THE WATER/CEMENT RATIO SHALL NOT EXCEED 0.55 FOR FOOTINGS AND 0.45 FOR ALL SLABS AND EXPOSED CONCRETE. THE MINIMUM AMOUNT OF CEMENT AND THE MAXIMUM SLUMP MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS SUBMITTED TO THE STRUCTURAL ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CONCRETE. (THE W/C RATIO LIMITS STILL APPLY). THE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, CEMENTITIOUS MATERIAL, FINE AND COARSE AGGREGATE, WATER AND ADMIXTURES AS WELL AS THE WATER/CEMENT RATIO, SLUMP, CONCRETE YIELD AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH ACI 301. CHEMICAL ADMIXTURES AND FLY ASH SHALL CONFORM TO ASTM C494 AND C618 RESPECTIVELY. FLY ASH PERCENTAGE OF TOTAL CEMENTITIOUS MATERIAL SHALL NOT EXCEED 20%. THE USE OF A PERFORMANCE MIX REQUIRES BATCH PLANT INSPECTION, THE COST OF WHICH SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER. REVIEW OF MIX SUBMITTALS BY THE ENGINEER OF RECORD INDICATES ONLY THAT INFORMATION PRESENTED CONFORMS GENERALLY TO CONTRACT DOCUMENTS. CONTRACTOR MAINTAINS FULL RESPONSIBILITY FOR SPECIFIED PERFORMANCE. CONCRETE MAY BE PLACED BY THE "SHOTCRETE" METHOD, PROVIDED THE APPROVALS, TESTS, AND INSPECTIONS REQUIRED BY THE BUILDING DEPARTMENT ARE OBTAINED. SHOTCRETE MATERIALS, EQUIPMENT, PROCEDURES, PROPORTIONS, BATCHING AND MIXING AND PLACEMENT SHALL BE IN ACCORDANCE WITH ACI 506R, ACI 506.2 AND IBC SECTION 1908. SHOTCRETE AGGREGATE SIZE SHALL NOT EXCEED 3/8". THE "SHOTCRETE" METHOD SHALL NOT BE USED WITHOUT MAKING SPECIAL ARRANGEMENTS THROUGH OWNER AND ENGINEER UNLESS STRUCTURAL DRAWINGS ARE SPECIFICALLY DETAILED TO ACCOMMODATE SHOTCRETING. 18. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1), GRADE 60, fy = 60,000 PSI. EXCEPTIONS: ANY BARS SPECIFICALLY SO NOTED ON THE DRAWINGS AS GRADE 40 SHALL HAVE fy = 40,000 PSI. GRADE 60 REINFORCING STEEL INDICATED ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING STEEL COMPLYING WITH ASTM A615 (S1) MAY BE WELDED ONLY IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN A.W.S. D1.4 ARE SUBMITTED. LONGITUDINAL REINFORCING STEEL IN DUCTILE FRAME MEMBERS AND IN SHEAR WALL BOUNDARY MEMBERS SHALL COMPLY WITH ASTM A706. ASTM A615 GRADE 60 REINFORCING STEEL IS ALLOWED IN THESE MEMBERS IF (A) THE ACTUAL YIELD STRENGTH BASED ON MILL TESTS DOES NOT EXCEED THE SPECIFIED YIELD STRENGTH BY MORE THAN 18,000 PSI (RETESTS SHALL NOT EXCEED THIS VALUE BY MORE THAN AN ADDITIONAL 3,000 PSI) AND (B) THE RATIO OF THE ACTUAL ULTIMATE TENSILE STRESS TO THE ACTUAL TENSILE YIELD STRENGTH IS NOT LESS THAN 1.25. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A1064. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. 19. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORDANCE WITH ACI 315 AND 318. LAP ALL CONTINUOUS REINFORCEMENT #5 AND SMALLER 60 BAR DIAMETERS, 2'-0" MINIMUM. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP CORNER BARS #5 AND SMALLER 60 BAR DIAMETERS OR 2'-0" MINIMUM. LAPS OF LARGER BARS SHALL BE MADE IN ACCORDANCE WITH ACI 318, CLASS B. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. PROVIDE (2) #5 MIN. U.N.O. TRIM BARS AROUND ALL OPENINGS IN CONCRETE WALLS OR SLABS EXTENDING 2'-6" PAST CORNERS, TYPICAL. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. NO REINFORCING BARS SHALL BE "WET -SET" INTO THE CONCRETE. PROVIDE A 20, LONG REBAR GROUND (UFER GROUND) PER ELECTRICIAN. 20. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: FOOTINGS AND OTHER UNFORMED SURFACES CAST AGAINST EARTH 3" FORMED SURFACES EXPOSED TO EARTH (i.e. WALLS BELOW GROUND) OR WEATHER (#6 BARS OR LARGER) 2" (#5 BARS OR SMALLER) 1-1 /2" COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1-1/2" SLABS AND WALLS (INTERIOR FACE) GREATER OF (BAR DIAMETER PLUS 1/8") OR 3/4" 21. CAST -IN -PLACE CONCRETE: SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND DIMENSIONS OF DOOR AND WINDOW OPENINGS IN ALL CONCRETE WALLS. SEE MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF MISCELLANEOUS MECHANICAL OPENINGS THROUGH CONCRETE WALLS. SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE, AND OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES, BOTH CAST -IN -PLACE AND PRECAST. WOOD 26. FRAMING LUMBER: SHALL BE KILN DRIED OR MC-19 (MOISTURE CONTENT LESS THAN 19%), AND GRADED AND MARKED IN CONFORMANCE WITH W.C.L.I.B. STANDARD NO. 17 GRADING RULES FOR WEST COAST LUMBER. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS (2X, AND 4X MEMBERS) DOUGLAS FIR OR HEM -FIR NO.2 BEAMS AND STRINGERS (INCLUDING 6 X AND LARGER MEMBERS) DOUGLAS FIR NO. 1 POSTS AND TIMBERS DOUGLAS FIR NO. 1 STUDS, PLATES & MISCELLANEOUS LIGHT FRAMING DOUGLAS FIR OR HEM -FIR NO.2 (AS NOTED ON PLANS / DETAILS) 27. GLUED LAMINATED MEMBERS SHALL BE FABRICATED IN CONFORMANCE WITH ASTM D3737 AND ANSI A190.1. EACH MEMBER SHALL BEAR AN A.I.T.C. IDENTIFICATION MARK AND SHALL BE ACCOMPANIED BY AN A.I.T.C. CERTIFICATE OF CONFORMANCE. CERTIFICATES OF CONFORMANCE MUST BE MADE AVAILABLE TO BUILDING INSPECTORS. ALL SIMPLE SPAN BEAMS SHALL BE DOUGLAS FIR COMBINATION 24F-V4, Fb = 2,400 PSI, Fv = 240 PSI, E = 1,800 KSI. ALL CONTINUOUS BEAMS SHALL BE DOUGLAS FIR COMBINATION 24F-V8, Fb = 2,400 PSI, Fv = 240 PSI, E = 1,800 KSI. CAMBER ALL SIMPLE SPAN GLULAM BEAMS TO 5,000' RADIUS UNLESS SHOWN OTHERWISE ON THE PLANS. 28. WOOD SHEATHING SHALL BE APA RATED, EXTERIOR GLUE; EXPOSURE 1, IN CONFORMANCE WITH THE REQUIREMENTS FOR THEIR TYPE IN DOC PS-1 OR PS-2. SEE PLANS FOR THICKNESS, PANEL IDENTIFICATION INDEX AND NAILING REQUIREMENTS. UNLESS OTHERWISE NOTED ON THE PLANS, ROOF AND FLOOR SHEATHING SHALL BE LAID UP WITH FACE GRAIN PERPENDICULAR TO SUPPORTS. ALL FLOOR SHEATHING EDGES SHALL HAVE APPROVED TONGUE -AND -GROOVE JOINTS OR SHALL BE SUPPORTED WITH SOLID BLOCKING. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF FLOOR AND ROOF SHEATHING. TOENAIL BLOCKING TO SUPPORTS WITH (2) 10d-F NAILS AT EACH END, UNLESS OTHERWISE NOTED. AT BLOCKED FLOOR AND ROOF DIAPHRAGMS PROVIDE FLAT 2X BLOCKING AT ALL UNFRAMED PANEL EDGES AND NAIL WITH EDGE NAILING SPACED PER PLANS. WHERE NOT NOTED OTHERWISE, NAIL PANEL EDGES WITH 8d NAILS @ 6" O.C. EDGES, 12" O.C. IN THE FIELD. 29. ALL WOOD EXPOSED TO WEATHER, OR BEARING ON UNPROTECTED CONCRETE OR MASONRY BELOW GRADE, OR BEARING ON UNPROTECTED CONCRETE OR MASONRY LESS THAN 8" FROM EXPOSED EARTH SHALL BE PRESSURE -TREATED, U.O.N. PRESSURE TREATMENT SHALL BE WITH AN APPROVED PRESERVATIVE AND BRANDED WITH A QUALITY CONTROL AGENCY MARK BY THE AMERICAN WOOD PRESERVERS BUREAU OR EQUAL. ALL METAL HARDWARE IN CONTACT WITH TREATED WOOD SHALL BE PROTECTED WITH A G185 GALVANIZED COATING (ZMAX) OR BETTER. ALL NAILS IN TREATED WOOD SHALL BE HOT -DIP GALVANIZED OR BETTER. PROVIDE 2 LAYERS OF 30# ASPHALT IMPREGNATED BUILDING PAPER BETWEEN NON -PRESSURE -TREATED LEDGERS, BLOCKING, ETC., AND CONCRETE OR MASONRY. 30. WOOD FRAMING NOTES: THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS: A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE IBC. MINIMUM NAILING, UNLESS OTHERWISE NOTED, SHALL CONFORM TO IBC TABLE 2304.10.1. COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. TIGHTEN BOLTS AND LAG SCREWS SNUGLY AGAINST WOOD FRAMING AFTER WOOD HAS REACHED SPECIFIED MOISTURE CONTENT. B. WALL FRAMING: ALL BEARING AND SHEAR WALLS SHOWN AND NOT OTHERWISE NOTED SHALL BE 2 x 4 STUDS @ 16" O.C. AT INTERIOR WALLS AND 2 x 6 @ 16" O.C. AT EXTERIOR WALLS. TWO STUDS MINIMUM SHALL BE PROVIDED AT THE END OF ALL BEARING AND SHEAR WALLS AND AT EACH SIDE OF ALL OPENINGS. SOLID BLOCKING FOR WOOD COLUMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. ALL BEARING STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH 16d NAILS AT 8" O.C. STAGGERED OR BOLTED TO CONCRETE WITH 5/8" DIAMETER ANCHOR BOLTS WITH 3"x3"x1/4" PLATE WASHERS @ 4'-0" O.C., UNLESS INDICATED OTHERWISE. INDIVIDUAL MEMBERS OF BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH 10d-F NAILS @ 8" O.C. STAGGERED. REFER TO THE PLANS AND SHEAR WALL SCHEDULE FOR REQUIRED SHEATHING AND NAILING. WHEN NOT OTHERWISE NOTED, PROVIDE GYPSUM WALLBOARD ON INTERIOR SURFACES AND GYPSUM SHEATHING ON EXTERIOR SURFACES ATTACHED TO ALL STUDS, TOP AND BOTTOM PLATES AND BLOCKING WITH SCREWS AT 8" O.C. USE 1-1/4 " W #6 SCREWS FOR 1/2" GWB AND 5/8" GWB WHERE OCCURS. USE 1-1/4" W #6 GALVANIZED SCREWS FOR 1/2" GWB AND 5/8" EXTERIOR GYPSUM SHEATHING, WHERE OCCURS. VERIFY THE FIRE ASSEMBLY REQUIREMENTS WHERE APPLICABLE WITH THE ARCHITECT. RECEIVED Nov 04 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT HAREZLAK ENGINEERING HAREZLAK ENGINEERING 11745 87th Ave. S. Seattle, WA 98178 PH: 360.224.0627 E: phil@harezlakengineering.com CONSULTANT STAMP: P HAR DRAWN / z BY: TA BY: BY: � 55577 FG /STERN G /ONAL MJH APPROVED BY: 11.02.2021 PAH Z N a W �00 N V ca Z a J LV }, Z. F_ Op v) _ _ N�o w a) Z o LL z /� v/ o ° a r � O w _ Z W OC wN ° w REVISIONS: NO. DESCRIPTION DATE PROJECT NUMBER: 21-064 ISSUE DATE: 11 /02/2021 CURRENT REVISION: PERMIT SHEET NAME: GENERAL STRUCTURAL NOTES/SHEET INDEX SHEET NUMBER: S10011 1■ L (E) 2X10 FLOOR J015T5 16" OG I- - - - - - - - - - - - - - - - - - - - - I FOUNDATION & FLOOR FRAMING PLAN NOTES: 1. CONTRACTOR TO FIELD VERIFY ALL EXISTING FRAMING AND DIMENSIONS. 2. (N) CONCRETE AND WOOD FRAMING SPECIFICATIONS PER GENERAL STRUCTURAL NOTES ON SHEET S1.0. RECEIVED Nov 04 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT HAREZLAK ENGINEERING HAREZLAK ENGINEERING 11745 87th Ave. S. Seattle, WA 98178 PH: 360.224.0627 E: phil@harezlakengineering.com CONSULTANT STAMP: Hq DRAWN / z BY: TA 0 5577 ECKE BY: MJH ONAL APPROVED BY: PAH 11.02.2021 Z N Q W O 00 Z a� J LV OQ O Q r � 0 _ � N Lu Z o z o� Q O w _ Z W DC Lu ° cN w REVISIONS: NO. I DESCRIPTION DATE PROJECT NUMBER: 21-064 ISSUE DATE: 11/02/2021 CURRENT REVISION: PERMIT SHEET NAME: MAIN FLOOR & FOUNDATION PLAN SHEET NUMBER: Simi SEE PL/ EXISTING 2ND FLOOR FRAMING PLAN FLOOR FRAMING PLAN NOTES: 1. CONTRACTOR TO FIELD VERIFY ALL EXISTING FRAMING AND DIMENSIONS. 2. PRIOR TO WALL REMOVAL, CONTRACTOR TO VERIFY THAT INTERIOR WALLS ARE NOT SHEATHED WITH PLYWOOD. IF PLYWOOD SHEATHING IS FOUND ON WALLS, PLEASE CONTACT HAREZLAK ENGINEERING FOR ADDITIONAL REVIEW AND RETROFIT. NEW 2ND FLOOR FRAMING PLAN HAREZLAK ENGINEERING HAREZLAK ENGINEERING 11745 87th Ave. S. Seattle, WA 98178 PH: 360.224.0627 E: phil@harezlakengineering.com CONSULTANT STAMP: HfjR WasyF�� DRAWN , z BY: TA5577 BCYECKE F �FG�STERF���� MJH ONAL APPROVED BY: PAH 11.02.2021 Z N ao W �CD N V ca Z a� J LV z O o o = _ �r w a� Z o LL 0�0 Q� w _ Z W DC Lu ° CN w REVISIONS: NO. I DESCRIPTION DATE PROJECT NUMBER: RECEIVE Nov 04 S�61ATE: Iv nr nn iA I 2021 DEV€�A499isRrO3,#�) N: DEPARTMENT PERMIT SHEET NAME: 2ND FLOOR FRAMING PLAN SHEET NUMBER: S1m2 SEE PLAN NOTE 2. 15T FLOOR EXI5TING/PROP05ED FLOOR PLAN EXISTING ROOF FRAMING, SEE PLAN NOTE 1. P0f)F FROMIIVC.. PI ON KI[)TFS- 1. BASED ON REVIEW OF EXISTING DRAWINGS, ROOF FRAMING CONSISTS OF PRE-MFR ROOF TRUSSES @ 24" OC. CONTRACTOR TO VERIFY SPACING AND ROOF FRAMING PRIOR TO CONSTRUCTION. DESIGN ASSUMES THAT TRUSSES FULL SPAN THE INTERIOR SPACE AND THERE ARE NO INTERIOR BEARING ELEMENTS. 2. PRIOR TO WALL REMOVAL, CONTRACTOR TO VERIFY THAT INTERIOR WALLS ARE NOT SHEATHED WITH PLYWOOD. IF PLYWOOD SHEATHING IS FOUND ON WALLS, PLEASE CONTACT HAREZLAK ENGINEERING FOR ADDITIONAL REVIEW AND RETROFIT. 3. CONTRACTOR TO FIELD VERIFY ALL EXISTING FRAMING AND DIMENSIONS. �- - - - - - - - - - - - - - - - - - - - - - - - - - - - 2ND STORY EXI5TIN(5 FLOOR PLAN (NO CHANGE) �(E) MGG TRUSSES ■ ■ HAREZLAK ENGINEERING HAREZLAK ENGINEERING 11745 87th Ave. S. Seattle, WA 98178 PH: 360.224.0627 E: phil@harezlakengineering.com CONSULTANT STAMP: Hq � P RF W A Stii y DRAWN / z BY: TA CHECKEFC 5577��� BY: / STE MJH S/ONAL APPROVED BY: PAH 11.02.2021 U) Z Cfl N Q W O 00 N V �Q ci) Z a300 z J W }, v) O �� o o _ _ w c) a� Z z w W Q� c� 0 IL _ Z OC w ° Lu REVISIONS: NO. I DESCRIPTION DATE PROJECT NUMBER: RECEIVED Nov 041S�I��F BATE: CITY OF�E�INT-0G(iNY�p/`G 2021 DEV�'kY�AE��VF N: PERMIT SHEET NAME: ROOF FRAMING PLAN SHEET NUMBER: S1m3 (E) 1.75x11-7/8" LVL (N) 2x FULL DEPTH BLKG W/ PLYWOOD SHIM TO (E) TJI JOISTS PER PLAN INSTALL BC4 POST CAP LVL/BLKG TO (N) BEAM BELOW; NAIL BLKG TO LVL (E) PLYWOOD SHEATHING w/ MIN (4) 16d NAILS AND NAILING (N) BC4 POST CAP, NEW BEAM TO LVL/BLOCKING Li ABOVE (N) DROPPED GLB PER PLAN (N) 4x6 POST (INSTALLED DEPTH ALONG BEAM LENGTH) w/ EPC4Z POST CAP DETAIL SCALE: NONE DETAIL SCALE: NONE 2 DETAIL SCALE NONE 3 (N) DROP BEAM TO POST & BEAM CONNECTION SCALE. NONE 4 u � >o CO Lu Q m CONTRACTOR TO CUT (2) 11" LONG SLITS IN U) cU) FLOOR TO ALLOW FOR (N) 4x6 POST 0 a CCQ INSTALLATION TO ABOVE, FASTEN J J BEAM BELOW INVERTED U U CCQ44SDS2.5 BASE (N) POST TO (E) BEAM BELOW (E) 4x8 GIRDER BEAM. JOISTS FRAMING INTO GIRDER NOT SHOWN FOR CLARITY (E) PLYWOOD SHEATHING AND NAILING (N) HGA10 EA. SIDE POST TO BOTTOM OF (E) GIRDER BEAM INSTALL (N) 4x4 POST AND FOOTING PER 12/S3.0 DIRECTLY BELOW (N) POST ABOVE lu >> : DETAIL SCALE: NONE 5 DETAIL SCALE: NONE 6 DETAIL SCALE: NONE 7 (N) BEAM TO BEAM CONNECTION SCALE: NONE 8 WALL ABOVE, NEW POST PER PLAN CONTRACTOR TO VERIFY IF SHEAR WALL LOCATION (2) %"O x 4%" SDS TOP AND BOTTOM (E) PLATE TO (N) 6x BLOCKING (E) JOIST WHERE (N) 4x8 BLKG. INSTALLED OCCURS BETWEEN (E) JOISTS DIRECTLY BELOW POST ABOVE; FASTEN TO ADJACENT JOISTS w/ (3)16d (N) 24" SQ x 10" DP NAILS AS SHOWN CONC. FTG w/ (3) #4 EW BOTTOM 11i (N) 4x4 POST w/ i AC4 POST CAP & ABU44Z POST BASE I% _ = W = TO (N) FTG CONTRACTOR TO PREPARE SUBGRADE FOR ADEQUATE AT CONNECTION TO (E) DOUBLE 2x10 GIRDER, BEARING CONDITIONS PROVIDE 1/2" PLYWOOD SHIM, FOR POST CAP CONNECTION. DETAIL SCALE: NONE 9 DETAIL SCALE: NONE 110 DETAIL SCALE: NONE 11 (N) POST THRU FLOOR CONNECTION SCALE: NONE 12 HAREZLAK ENGINEERING HAREZLAK ENGINEERING 11745 87th Ave. S. Seattle, WA 98178 PH: 360.224.0627 E: phil@harezlakengineering.com CONSULTANT STAMP: Hq WA S���� DRAWN , z BY: TA CHECKE �� 5577��� BY: / STD MJH �'ONAL APPROVED BY: 11.02.2021 PAH Z N a W �CD N V CO Z j J LV a. }, .. o� F �� — elf a)Z o z w V/� � W o r Q Lu o� _ 00� elf im Lu REVISIONS: NO. I DESCRIPTION DATE PROJECT NUMBER: RECEIVED Nov 04 I I�II�II//nn��I ATE: CITY OF EDMO A212021 DEVEMPI �ON: PERMIT SHEET NAME: STRUCTURAL DETAILS SHEET NUMBER: S3mO