APPROVED BLD2021-1615+Mechanical_Plan+11.30.2021_11.21.55_AM+2543558GENERAL NOTES LEGEND ALL WORK SUBJECT TO FIELD GENERAL NOTES — MECHANICAL SHEET METAL NOTES ACU AIR CONDITIONING UNIT 1. REFERENCE TO RELATED WORK: "REF" INDICATIONS DENOTE WORK 1. REFERENCE: SMACNA HVAC DUCT CONSTRUCTION STANDARDS, ARCHITECTURAL BACKGROUND AFF ABOVE FINISHED FLOOR COVERED ELSEWHERE (ARCHITECTURAL, STRUCTURAL, CIVIL, METAL AND FLEXIBLE, CURRENT EDITION (SMACNA HVACDCS). (THIN LINE) AHJ AUTHORITY HAVING JURISDICTION INSPECTION FOR ELECTRICAL, LANDSCAPE, OR KITCHEN), OR ITEM BASED ON A 2. CLEARANCE: COORDINATE DUCTWORK WITH MISCELLANEOUS AHU AIR HANDLING UNIT SPECIFIC MANUFACTURER'S DIMENSIONS (VERIFY). OBSTRUCTIONS IN CEILING SPACE. NEW MECHANICAL WORK BDD BACKDRAFT DAMPER 2. ELECTRICAL CHARACTERISTICS: REFER TO ELECTRICAL DRAWINGS FOR 3. DUCTWORK SIZES: SIZES INDICATED ARE INSIDE CLEAR (HEAVY LINE) BTUH BRITISH THERMAL UNIT PER HOUR CODE COMPLIANCE ELECTRICAL CHARACTERISTICS (VOLTAGES, ETC.) OF MECHANICAL DIMENSIONS. — — CBBDD COUNTERBALANCED BACKDRAFT EQUIPMENT, UNLESS OTHERWISE INDICATED. MATCHLINE OR PROPERTY LINE DAMPER 4. ROUND ELBOWS AND OFFSETS: FULL RADIUS (R/D = 1.5), 3. CODES: COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM CC COOLING COIL SHALL BE PER THE APPLICABLE BUILDING, MECHANICAL, ENERGY, 5-PIECE SEGMENTED OR STAMPED. REFER TO SMACNA HVACDCS EF-1 PLUMBING, FIRE, AND HEALTH CODES AND REGULATIONS N ADOPTED FIG 2-7, 3-3. DO NOT USE ANGLED OFFSET (TYPE 1). CD CEILING DIFFUSER BY THE LOCAL AHJ. MITERED OFFSET (TYPE 2) MAY BE USED UP TO 30 DEGREE TYPICAL EQUIPMENT DESIGNATION CFM CUBIC FEET PER MINUTE OFFSET ANGLE. (EXHAUST FAN SHOWN) CLG CEILING, COOLING 4. MECHANICAL CONTRACTOR SHALL LOCATE AND COORDINATE EXACT 5. ROUND TEES AND LATERALS: CONICAL TEE PER SMACNA HVACDCS COMB COMBUSTION LOCATION OF ALL MECHANICAL EQUIPMENT WITHIN THE STRUCTURE. FIG 3-5; DO NOT USE STRAIGHT TEE; DO NOT USE CONICAL ROOM THERMOSTAT OR CONTR CONTRACTOR APPROVED5. PENETRATIONS: PROVIDE ESCUTCHEON PLATES FOR EXPOSED SADDLE TAP FOR EXPOSED DUCTWORK IN FINISHED SPACES. 90- O TEMPERATURE TRANSMITTER D DRAIN DIAMETER PIPING PENETRATIONS AND SHEET METAL FLASHING FOR EXPOSED DEGREE TEE WITH OVAL TO ROUND TAP, LATERAL, AND 45- DUCTWORK PENETRATIONS. DEGREE RECTANGULAR LEAD-IN PER SMACNA HVACDCS FIG 3-4. o DB DRY BULB, DECIBEL DUCT SMOKE DETECTOR DISCH DISCHARGE 6. RECTANGULAR ELBOWS AND OFFSETS: FULL RADIUS WHERE SPACE 6. SHAFT AND PLENUM CONNECTIONS: SEAL CONNECTIONS TO AIR SHAFTS AIRTIGHT. PROVIDE AIRTIGHT SEAL AROUND PERMITS, R/W = 1.5; OTHERWISE USE SQUARE CORNER ELBOW DMPR DAMPER WITH TURNING VANES. DN DOWN PLANS MUST E INSULATION/LINING NOTES 7. RECTANGULAR DIVIDED FLOW FITTINGS: USE GENERALLY, DUCT (1ST FIGURE = SIDE SHOWN, EA EXHAUST AIR EXCEPT BRANCHES TO TERMINALS; SMACNA HVACDCS FIG 2-5, 18x12 2ND FIGURE = SIDE NOT SHOWN) EAT ENTERING AIR TEMPERATURE 1. ENERGY CODE: AS A MINIMUM, COMPLY WITH THICKNESSES AND EER ENERGY EFFICIENCY RATIO TYPES LISTED IN ENERGY CODE ENFORCED BY AHJ. UP DOWN EF EXHAUST FAN ON 2. EXTENT OF INTERNAL DUCT LINING: DUCT SECTION, POSITIVE PRESSURE EFF EFFICIENCY JO SITEA. GRILLE AND DIFFUSER BOXES AND BOOTS. EG EXHAUST GRILLE, ENGINE GENERATOR B. TRANSFER DUCTS. UP DOWN EL ELEVATION 3. MISCELLANEOUS DUCT FITTINGS (CONICAL TAKEOFFS, ETC.): DUCT SECTION, NEGATIVE PRESSURE ELEC ELECTRIC WRAP WITH INSULATION FOR CONDENSATION CONTROL. EQUIV EQUIVALENT r--------------------------------------------------------------------� ESP EXTERNAL STATIC PRESSURE 4. EXTENT OF EXTERNAL DUCT INSULATION: UP DOWN At the time o final inspection an � A. SUPPLY AND RETURN AIR IN MECHANICAL ROOMS, ELECTRICAL ROOMS, EXT EXTERIOR, EXTERNAL AND EQUIPMENT ROUND DUCT SECTION F FAHRENHEIT engineered design for attachment of the ROOMS NOT SPECIFIED TO BE INTERNALLY LINED. FCU FAN COIL UNIT I I B. SUPPLY AIR ABOVE CEILINGS. C. OUTDOOR AIR INTAKE. FD FIRE DAMPER, FLOOR DRAIN ;equipment to structure will be required. UP UP UP DUCT PENETRATION THRU FLOOR FLR FLOOR Please provide a stamped design to the 0 A m OR ROOF FLTR FILTER p g FPM FEET PER MINUTE City Inspector. FSD FSD FIRE/SMOKE DAMPER FPS FEET PER SECOND i I (�= HORIZ DUCT, G GAS I �= VERT DUCT), GWB GYPSUM WALLBOARD PROJECT DESCR PTO 2-HR RATED, UON HORIZ HORIZONTAL FD FD HP HORSEPOWER T 1 FIRE DAMPER HVAC HEATING, VENTILATING, AND AIR CONDITIONING REPLACE EXISTING 18 TON CAPACITY AIR-COOLED CHILLER HVACDCS HVAC DUCT CONSTRUCTION STANDARDS, METAL AND 90° ELBOW, R/D OR R/W=1.5 FLEXIBLE (SMACNA) KW KILOWATT L LONG, LENGTH SQUARE CORNER ELBOW WITH MBH THOUSAND BTU PER HOUR TURNING VANES MECH MECHANICAL MCA MINIMUM CIRCUIT APPUCABLE CODES AMPACI 90° TAKE -OFF OR TEE MOCP MAXIMUM OVER CURRENT PROTECTION OTECTION MTD MOUNTED OA OUTDOOR AIR THESE DRAWINGS ARE BASED ON THE FOLLOWING CODES: 45° LATERAL TAKE -OFF OBD OPPOSED BLADE DAMPER OD OUTSIDE DIMENSION OR DIAMETER -2018 INTERNATIONAL BUILDING CODE WITH CITY AMENDMENTS OPNG OPENING -2018 INTERNATIONAL MECHANICAL CODE WITH CITY AMENDMENTS TRANSITION OR REDUCER (FOT= -2018 INTERNATIONAL ENERGY CODE WITH CITY AMENDMENTS FLAT ON TOP, FOB -FLAT ON PD PRESSURE DROP, PUMPED DRAIN BOTTOM) POC POINT OF CONNECTION PRV PRESSURE REDUCING VALVE 90° RECTANGULAR TAKE -OFF WITH PSIG POUNDS PER SQUARE INCH GAUGE 45° TAPER RA RETURN AIR V C�N�TY MAP REF REFERENCE 90° DIVERGING RECTANGULAR TEE, RG RETURN GRILLE EITHER RADIUS OR TURNING VANES SA SUPPLY AIR SCH SCHEDULE SF SUPPLY F PROJECT SITE 0 ROUND DUCT INDICATOR SENS SENSIBLEE, SQUARE FOOT SG SUPPLY GRILLE + SMACNA SHEET METAL AND AIR CONDITIONING �. .�. CD-12x12 CD-1`iDIFFUSER/GRILLE TYPE, AND NUMBER CONTRACTORS NATIONAL IL 1.._,I - OR OR SIZE ASSOCIATION `i T C * _ ` 400 400 `*` DESIGN CFM (WHERE APPLICABLE) SO SCREENED OPENING 1.-208t,.... _ - CEILING DIFFUSER (FLOW ARROWS CEILING STATIC PRESSURE ¢ $ # TG TRANSFER GRILLE SHOWN ONLY IF AIRFLOW NOT TYP TYPICAL ! SYMMETRICAL) tr ` - UON UNLESS OTHERWISE NOTED APPROVED BY PLANNING E _ �_ VD VOLUME DAMPER *hyst., F� CEILING RETURN/EXHAUST GRILLE 11/30/2021 r- • Ther.■ 'Edmo * *s � WALL SUPPLY GRILLE (SG) •. ' ! • WALL RETURN/EXHAUST GRILLEr ;�17RMUcychn DRAWNG NDEX d1PSuZg1, Mir _. - �4 TRANSFER GRILLE (TG), DUCT CONNECTED, WALL MOUNTED WITH M-1 LEGEND, GENERAL NOTES, DRAWING INDEX ± 50 M-2 HVAC ROOF PLAN City Of Edmonds Building Department Work MECHANICAL Address 21401 72ND Owner THE EVERETT CLINIC Approved Date 12/01 /2021 Building Official Eric) Cawfer Permit Number BLD2021-1615 =rM-3 ELEVATION Btr1t7� ad+ . Kam~ ,•,•.�` • i j • - L� �+ ti - M-5 UNIT DATA . Apa imeni HomBrijl #an ~ YTRANSFER GRILLE, CEILING MOUNTEDLd j JWITH FULL-SIZED LINED DUCT k �7 t f Vvinco Foods, k .CONNECTION_PROJECT �NFORMAT�ON 47. , AIRFLOW THRU DOOR GRILLE OR 220th St Syr2 UNDERCUT W/OPTIONAL CFM SHOWN 2Dth"St ' 4 - j . Harbor-Freigh Tools/ L E y _ 'M6 . 11 FLEXIBLE DUCT • I •- tsperarrce ��}�r 7c.Vie+�vjArena , �._ �I t { r k j F T t Park O I# f G i-aS I I- I �•�}N� �R �����i �■ ` F r L Don Xrea ' R E • y ' } * t * * , N . ­ - 7 . - J. • *fir f i I y (316 I\ 41 11 LI tl : IVi a fiCJetAMM t '.I W, -1 P11 pp00❑❑000�0 ppp ..................Mq W hy/ � O ❑ :� ❑ O 4 QFC45976 O •.. /STER..• ��p ��oFSS�ONAL E�\�pp -21 °�a❑❑❑o�0�1-2� EXPIRES: 1 0/25/22 ISSUE: U z 3 w d Q z N W x BLD2021-1615 RECEIVED Nov 30 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET NO. M-1 LEGEND, GENERAL NOTES, DRAWING INDEX 3 PROJECT NO. 020-042 11-27-20 CH-1 'Orl NOTE: REPLACEMENT CHILLER TO BE CONNECTED TO EXISTING HYDRONIC PIPING SYSTEM. ANY PIPING ADDITIONS OR MODIFICATION TO EXISTING PIPING REQUIRED TO ACCOMMODATE NEW CHILLER SHALL FULLY COMPLY WITH SECTION 1202 OF THE SM C FOR PIPING, FITTING, VALVES, ETC. AND MEET OR EXCEED THE RATING OF THE EXISTING SYSTEM (150#). p°Doo❑o0p00 00� �eN�R..... ��M,y �pp #p pF WASy�� ❑ :� ❑ S'6G STER�`�' ��0004 ppOFss/ONAL ENG\�� o goo❑❑aoo°11-2� -21 EXPIRES: 10/25/22 SSUE: W x 3 w d i Q z N RECEIVED Nov 30 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEE I NO. I WOR4. E-44 H VAC PLAN - ROOF SCALE: 1 /8" = 1'-0" z SITE PLAN PROJECT NO. 020-042 11-2 / -20 COPYRIGHT 2021 PINEHURST ENGINEERING, PLLC