REVIEWED BLD2022-0153+Manufacturer_Specifications_and_Installation_Instructions+2.4.2022_9.26.00_PM+2663918
TRANS® BLD2022-0153 RECEIVED Feb 07 2022 CITY OF EDMONDS DEVELOPMENT SERVICES 4WCY4036B-SUB-3 REVIEWED 3 Ton Convertible Heat Pump Packaged Units BY CITY OF EDMONDS 4WCY4036B3000A PRODUCT SPECIFICATIONS MODEL 4WCY4036B3000A RATED Volts/PH/Hz 208-230/3/60 Performance Cooling BTUHO 36000 Indoor Airflow (CFM) 1200 Power Input (KW) 3.15 EER/SEER (BTU/Watt-Hr.)© 11.75 / 14.0 Sound Power Rating [dB(A)]OO 69 Performance Heating0 (High Temp.)BTUH 32400 Power Input (KW) 2.4 (Low Temp.) BTUH 24800 Power Input (KW) 2.6 HSPF (BTU / Watt-HQ6 8.0 POWER CONN.—V/Ph/Hz 208-230/3/60 Min. Brch. Cir. Ampacity0 18.4 Fuse Size — Max. (amps) 25 Fuse Size — Recmd. (amps) 25 COMPRESSOR SCROLL Volts/Ph/Hz 208-230/3/60 R.L. Amps — L.R. Amps 10.4 / 73 OUTDOOR COIL — TYPE SPINE -FIN Rows/F.P.I. 2 / 24 Face Area (sq.ft.) 15.49 Tube Size (in.) 3/8 Refrigerant Control EXPANSION VALVE INDOOR COIL — TYPE PLATE FIN Rows/F.P.I. 4 / 15 Face Area (sq.ft.) 3.54 Tube Size (in.) 3/8 Refrigerant Control EXPANSION VALVE Drain Conn. Size (in.) 3/4 FEMALE NPT OUTDOOR FAN —TYPE PROPELLER Dia. (in.) 23.4 Drive/No. Speeds DIRECT / 1 CFM @ 0.0 in. w.g.® 3250 Motor— HP/R.P.M. 1/5 / 830 Volts/Ph/Hz 230/1 /60 F.L. Amps/L.R. Amps 1.1 / 1.9 INDOOR FAN — TYPE CENTRIFUGAL Dia x Width (in.) 10 X 10 Drive/No. Speeds DIRECT / VARIABLE CFM @ 0.0 in. w.g.Os SEE FAN PERFORMANCE TABLE Motor— HP/R.P.M. 1/2 / VARIABLE Volts/Ph/Hz 200-230/1 /60 F.L. Amps/L.R. Amps 4.3 / 4.3 FILTER / FURNISHED NO Type Recommended THROWAWAY Recmd. Face Area (sq. ft.)OO 4.0 REFRIGERANT R41CA Charge (Ibs.) 7.4 DIMENSIONS H X W X L Crated (in.) 47.86 / 44.5 / 52.03 WEIGHT Shipping (lbs.) / Net (lbs.) 468 / 372 O Certified in accordance with the Unitary Air -Conditioner Equipment certification program, which is based on AHRI Standard 210/240. ® Sound Power values are not adjusted for AHRI 270-95 tonal cor- rections. ® Calculated in accordance with currently prevailing Nat'l Electrical Code. ® Standard Air — Dry Coil — Outdoor. © Standard Air —Wet Coil — Indoor. © Rated in accordance with D.O.E. test procedure. O Filters must be installed in return air system. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendations with clean resistance of 0.05" W.C. 0 2012 Trane Dimensional Data and Weights I 119-5/8j i- I-- 1-- .11 LEFT SIDE 18.03 18.29 123/32] Ll [23/32] 14.22 19/161 SECTION Y-Y TYPICAL (8) SIDES OF DOWNFLOW DUCT OPENINGS NOTE: The view labeled `Bottom Side" represents the Base as viewed looking up from underneath the unit. I VI wl- OUTLET FRONT SIDE M BOTTOM SIDE 1 2 4WCY4024 through 4WCY4036 (1 of 3) Dimensional Data and Weights RECOMMENDED CLEARANCE .COMBUSTIBLE 304.£ [121 ( INSIDE 84.2 [3-. 24V ENTRY 359.79 I } (14-5/321 288.42 225.68 [11-11/32] 18-7/81 117.73 [ 4 - 5 / 8 1 4vv.4v [161 (INSIDE) BOTTOM DUCT OPENINGS POWER ENTRY 28.58 [1-1/8) DIA. KNOCKOUT 180.20 [1-3/321 118.08 POWER ENTRY 28.58 [1-1/8) DIA. KNOCKOUT 34.93 [1-3/81 DIA. KNOCKOUT 150.94 50.01 [1-31/321 DIA. KNOCKOUT [5-15/16] SINGLE POINT ENTRY 34.93 [1-3/81 DIA. KNOCKOUT RIGHT SIDE 62.1 [I-3I/32DIA. KNOCKOUT 62.71 [2-15/321 DIA. KNOCKOUT 4WCY4024 through 4WCY4036 (2 of 3) 406.40 [161 (INSIDE) .i7 CLEARANCE .COMBUSTIBLE 304.£ [121 ( INSIDE 84.2 [3-. 24V ENTRY 359.79 I } (14-5/321 288.42 225.68 [11-11/32] 18-7/81 117.73 [ 4 - 5 / 8 1 4vv.4v [161 (INSIDE) BOTTOM DUCT OPENINGS POWER ENTRY 28.58 [1-1/8) DIA. KNOCKOUT 180.20 [1-3/321 118.08 POWER ENTRY 28.58 [1-1/8) DIA. KNOCKOUT 34.93 [1-3/81 DIA. KNOCKOUT 150.94 50.01 [1-31/321 DIA. KNOCKOUT [5-15/16] SINGLE POINT ENTRY 34.93 [1-3/81 DIA. KNOCKOUT RIGHT SIDE 62.1 [I-3I/32DIA. KNOCKOUT 62.71 [2-15/321 DIA. KNOCKOUT 4WCY4024 through 4WCY4036 (2 of 3) 406.40 [161 (INSIDE) .i7 304.£ [121 ( INSIDE 84.2 [3-. 24V ENTRY 359.79 I } (14-5/321 288.42 225.68 [11-11/32] 18-7/81 117.73 [ 4 - 5 / 8 1 4vv.4v [161 (INSIDE) BOTTOM DUCT OPENINGS POWER ENTRY 28.58 [1-1/8) DIA. KNOCKOUT 180.20 [1-3/321 118.08 POWER ENTRY 28.58 [1-1/8) DIA. KNOCKOUT 34.93 [1-3/81 DIA. KNOCKOUT 150.94 50.01 [1-31/321 DIA. KNOCKOUT [5-15/16] SINGLE POINT ENTRY 34.93 [1-3/81 DIA. KNOCKOUT RIGHT SIDE 62.1 [I-3I/32DIA. KNOCKOUT 62.71 [2-15/321 DIA. KNOCKOUT 4WCY4024 through 4WCY4036 (2 of 3) 406.40 [161 (INSIDE) .i7 Dimensional Data and Weights 115-11/161 (OUTSIDE) BACK DUCT OPENINGS 530.60 17.78 [II/16] [20-7/81 Xv � X SECTION X-X TYPICAL (8) SIDES OF SIDEFLOW DUCT OPENINGS 1105.06 [43-1/2) (SURFACE AREA) BACK SIDE /16] DE ) 9 /32] 9 4] MODEL HEIGHT MM/IN. APPROX. CORNER WEIGHT - KG/LBS SHIPPING WEIGHT KG/LBS TOTAL UNIT WEIGHT KG/LBS CENTER OF GRAVITY MM/IN. A WI W2 W3 W4 B C 4TCY4024/030 898.53 (35-3/81 56.7 (1251 35.8 (791 25.4 (561 39.9 (881 201.6 (4441 157.9 (3481 401.3 [15.81 508.0 [20.01 4TCY4036 949.33 137-3/81 57.6 11271 36.3 1801 25.9 (571 40.8 (901 204.3 (4501 160.6 13541 401.3 [15.81 508.0 120.01 4WCY40241030 898.53 135-3/81 57.6 11271 36.3 1801 26.3 1581 41.7 1921 205.1 (4531 161.9 (3571 401.3 [15.81 515.6 [20.3] 4WCY4036 949.33 137-3/81 60.8 11341 38.1 1841 27.2 1601 42.6 (941 212.5 [468] 168.7 [372] 401.3 [15.81 508.0 120.01 4WCZ6036 949.33 137-3/81 60.8 11341 38.1 [841 27.2 1601 42.6 (941 212.5 [468] 168.7 [372] 401.3 [15.8) 508.0 120.01 4WCY4024 through 4WCY4036 (3 of 3) Unit Performance Data Indoor Fan Performance 4WCY4O36A Horizontal Airflow 4WCY4036-HOR DIPSWITCH SETTINGS External Static Pressure (in. wg) AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 350 CFM/TON OFF OFF OFF ON Watts 162 173 197 226 256 285 313 343 360 - - CFM 1058 1062 1063 1063 1062 1060 1057 1053 1010 400 CFM/TON' OFF OFF OFF OFF Watts 179 230 265 296 329 366 403 431 436 CFM 1179 1196 1204 1206 1205 1203 1199 1194 1185 450 CFM/TON OFF OFF ON OFF Watts 318 336 365 399 435 469 502 533 - CFM 1390 1376 1370 1366 1361 1354 1349 1351 Down Airflow 4WCY4036-DOWN DIPSWITCH SETTINGS External Static Pressure (in. wg) AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 350 CFM/TON OFF OFF OFF ON Watts 169 182 210 243 273 301 331 370 433 - - CFM 1025 1062 1068 1063 1060 1061 1064 1055 1015 400 CFM/TON` OFF OFF OFF OFF Watts 225 253 283 315 348 381 414 449 484 CFM 1187 1201 1203 1201 1198 1197 1194 1184 1157 450 CFM/TON OFF OFF ON OFF Watts 339 357 390 424 455 483 516 571 - CFM 1391 1377 1377 1375 1366 1352 1344 1360 *Factory Default Setting 4WCY4036 AIRFLOW WITH AUXILIARY HEAT (CFM) SWITCH SETTINGS SELECTION NOMINAL AIRFLOW 7-OFF 8-OFF LOW 1050 CFM 7-ON 8-OFF HIGH 1200 CFM 7-OFF 8-ON HIGH 1200 CFM 7-ON 8-ON HIGH 1200 CFM BAYHTRV305, 308, 310, 315E, Supplementary Electric Heater UNIT MODEL ELECTRIC HEATER MODEL RATED VOLTAGE PHASE AMPS HEATER CAPACITY STAGES KW/STAGE MCA MAX FUSE OR HACR CKT BKR SIZE (4) CANADA ONLY MAX. CKT BKR SIZE (5) KW BTUH 1 2 ^W/TCY4036-060A3 BAYHTRV305E 208/240 3 10/12 3.76/5.0 12800/17100 1 3.76/5.0 13/15 15/15 15/15 ^W/TCY4036-060A3 BAYHTRV308E 208/240 3 17/19 6.0/8.0 20500/27300 1 6.0/8.0 21/24 25/25 25/25 ^W/TCY4036-060A3 BAYHTRV310E 208/240 3 21/24 7.5/10.0 25600/34100 1 7.5/10.0 26/30 30/30 30/30 ^W/TCY4036-060A3 BAYHTRV315E 208/240 3 31/36 11.27/15.0 38500/51200 2 7.5/10.0 3.76/5.0 39/45 40/45 40/45 BAYSPEK61, 64E Single Power Entry Kit SINGLE POWER ENTRY KIT HEATER MODEL UNIT MODEL BAYSPEK061 E BAYHTRV305E 4WCY4036-060A3 BAYHTRV308E 4WCY4036-060A3 BAYHTRV310E 4WCY4036-048A3 BAYSPEK064E BAYHTRV315E 4WCY4036-06OA3 BAYCURB050A Full Perimeter Roof Mounting Curb for 4WCY4024-036 3€ 14 1 1/2 RETURN / AIR SUPPLY AIR C D CHANNEL SIDE CHANNEL END I WOOD NAILER I I I I I I I I I I I I I I I I I HOLE it N ROOF I I � 43 3/8 35 7/8 - 3 5/8 3/16 The drawings on this page are prepared by the manu- facturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. SERVICE CLEARANCE DIMENSIONS A B C D WC*/TC* 42.00 36.00 12.00** 24.00 DC*/YC* 42.00 36.00 12.00** 36.00 / ** 42.00 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY Optional Equipment BAYFLTR101, 201 B, 1 " - 2" Filter Rack (Mounts in Filter/Coil Section) BAYACCDORI A & BAYACCDOR2A Hinged Filter Access Door Replaces Filter/Coil Access Panel The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not respon- sible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. Optional Equipment BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) HVAC Unit A Economizer eeeeeeeeee rain hood eeeeeeeee�e Outside ai dampers Z. Required c tReturn air filter kit, order ampers separately Mist limi- o . nator Relief damper Return Roofcurb Duct Economizer Unit Application Models A BAYECON101A 4TC*,WC`,YC',DC` 20.125" 018-036 BAYECON102A 4TC' DC' 24.375" *WC",YC`, 042-060 BAYCON200,201A Horizontal Economizer and Rain Hood The drawings on this page are prepared by the manu- facturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manu- facturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. Economiz Duct Economizer A B C D E F BAYECON200AA 22" 20" 16 7/8" 15 11/16 11 11/16 15 BAYECON201AA 26" 22 21/32" 19" 17 11/16 14 11/16 21-3/8 I Optional Equipment BAYOSAH001,002A, 25% Outside Air Damper (Replaces Filter/Coil Access Panel) The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the ZR unauthorized use of these drawings and expressly disclaims any liability for dam- ages resulting from such unauthorized use. Manual Fresh Air Model Unit Application Models A B C D 4YC,WC3018-036 BAYOSAH001 4TC`3018-036 4W/T/Y/DCY4024-036 22 7/16" 20 11 /16" 12 3/8" 9 3/16" 4W/Y/DCZ6036 4YC, W C3042-060 BAYOSAH002 4TC`3042-060 4W/T/Y/DCY4042-060 25 3/16" 20 11 /16" 12 3/8" 9 3/16" 4W/Y/DCZ6048-060 FULLY OPEN FULLY- B CLOSED BAYDMPR101,102A, 25% Motorized Outside Air Damper (Mounts Over Horizontal Return Air Opening) 10 *— D—* Unit Application Models A B C D E 4YC, WC3018-036 BAYDMPR101A 4TC3018-036 4W/T/Y/DCY4024-036 1513/16" 1113/16" 10 1/4" 111/2" 12 1/4" 4W/Y/DCZ6036 4YC, WC3042-060 BAYDMPR102A 4TC3042-060 4W/T/Y/DCY4042-060 18 3/16" 15 1/8" 10 1/4" 11 1/2" 12 1/4" 4W/Y/DCZ6048-060 i 0 10 Mechanical Specifications General The units shall be horizontal airflow as shipped and convertible to downflow. All units shall be factory assembled, piped, internally wired and fully charged with refrigerant. All units shall be factory run tested to check cooling operation, fan and blower rotation and control or TXV se- quence. Units shall be designed to operate at ambient temperatures between 115°F and 55°F in cooling as manufactured. Cooling performance shall be rated in ac- cordance with A.H.R.I. standards. Unit Casing All components shall be mounted in a weather -resistant steel cabinet with an enamel finish. Access panels shall be pro- vided for unit controls and indoor coil and fans. Indoor air section compartment shall be completely insulated with fireproof, permanent, odorless glass fiber material. Knockouts shall be provided for utility and control connections. Drain connections shall be provided to accommodate indoor water runoff. Compressor The compressor shall be hermetically sealed, high efficiency Climatuff° com- pressors. Internal overcurrent and over temperature protection, internal pressure relief shall be standard. Refrigeration System All units shall have TXV in cooling and TXV in heating. Service pressure tap ports, and a refrigerant line filter dryer shall be stan- dard. Indoor Coil Coils shall be internally finned or smooth bore 3/8" copper tubes mechanically bonded to configured aluminum plate fin as standard. Evaporator coil leak and pressure tested to 200 psig; condenser coil tested to 450 psig. Tirane 6200 Troup Highway Tyler, TX 75707-9010 Condenser Coil — The Spine Fin TMcondenser coil shall be continuously wrapped, corrosion resis- tant all aluminum with minimum brazed joints. This coil is 3/8 inch O.D. seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Indoor Air Fan — Direct -drive, forward - curved, centrifugal wheel in a Composite Vortica° Blower housing. Motor shall have thermal overload protection. Permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber mounts. Condenser Fan — Direct -drive, draw thru propeller type. Weather -proofed permanent split capacitor fan motor shall have built-in thermal overload and per- manently lubricated motor bearings. System Controls System controls include condenser fan, evaporator fan and compressor contac- tors. Accessories Roof Curb —The roof curb shall be de- signed to mate with the unit and provide support and complete weathertight instal- lation when properly installed. Adhesive back polyurethane sealing strips shall be provided to ensure an airtight seal be- tween supply and return openings of the curb and unit. The roof curb design allows field fabricated ductwork to be connected directly to the curb. Curb ships knocked down for field assembly, and includes factory -installed wood nailer strips. Electric Heaters — Each heater assem bly shall include power supply fusing if over 48 amps, automatic resetting limit switches and heat limiters for thermal protection. Heaters shall be provided with polarized plugs for quick connection to unit low voltage wiring. Electric heat mod- ules shall be UL listed. Single Source Power Entry — This ac- cessory when used with electric heat accessory shall allow single source power connection to unit and heater combina- tion. Single source power entry kits shall have specific matching heater(s). Kit shall include high voltage terminal blocks, fuse blocks and fuses, cut -to -length in- terconnecting wiring, and junction box (if required) to provide power sources with fuse protection as required for both the unit and accessory heater. Kit compo- nents shall install within the unit cabinet in the heater access section. Single source branch power circuit shall be protected and wired in accordance with local codes. Fully Modulating Economizer — This accessory shall be field installed and be composed of the following items: 0-100% fresh air damper, damper drive motor, fixed dry bulb enthalpy control, and low voltage wiring plug for electrical connections. Solid state enthalpy or differential enthalpy con- trol is optional. Economizer operations shall be controlled by the preset position of the enthalpy control. A barometic relief damper shall be standard with the econo- mizer and provide a pressure operated damper that shall be gravity closing and prohibit entrance of outside air on equip- ment "off' cycle. Economizer requires BAYRLAY004A relay kit to interface the economizer to the heat pump. Manual Outside Air Dampers — Rain hood and screen shall be field installed. Suitable for up to 25% outside air. Start Kit — Extra compressor starting ca- pacity for single phase equipment. Control Options Standard Indoor Thermostats — Two stage heating/cooling or one stage heat- ing/cooling thermostats shall be available in either manual or automatic changeover. Programmable Electronic Night Set- back Thermostat — Programmable electronic thermostat shall provide heat- ing setback and cooling setup with 7-day, programming capability. 1 H/1 C or 2H/2C models available. COTUS $TE Intertek The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.