Loading...
FIR2021-0044+Calculations+4.30.2021_9.36.27_AM+2172825State of Washington 1Y1 Yt Sprinkler License # Designer: Kenneth H. Robinson RO-BI-NP-*272C2, Level 3 Robinson-Elmslie 29330124th Ave N.E. State of Washington Sprinkler Plumbing Inc 01403--7462 A 98223 Comp tancyertificate of #7659-0106-CE L-3 Builder: Advantage Contractors Property address: 7412 176th St SW, Edmonds (Weiss - Cook Residence) Total quantity of sprinkler heads: 27 Fire sprinkler system notes: * Fire sprinkler system design per NFPA 13d (standard for houses and duplexes). * Fire sprinkler system to be pressure tested and flow tested. * Sprinkler piping and fittings to be C.P.V.C. "Flameguard" by Speers Mfg. * Installation of C.P.V.C. pipe and fittings to be done by manufacturer certified installers. * Underground water service to be combination fire and domestic. * Sprinkler heads to be Globe Sprinkler Co. "Inch" concealed pendant with escutcheons per listing. SIN # GL4906 and Globe sidewll SIN # GL3241. Dry head for outdoor fireplace Globe GL5641. * Lines in attic to be protected from freezing with tent insulation (by others). * Sprinkler system to supply water connection for toilets, providing "flow through" in lieu of backflow prevention. Dead end branch lines shall be kept to no more than 20' in length. * Design spacing is 16' x 16' (256 square feet). * Design Density is minimum .05 gpm/square foot * Design area is for 2 head simultaneous flow. * Minimum flow requirements are: (1) head flow =13 gpm @7.0 psi (flat or sloped ceilings) (2) head flow =13 gpm (ea) @ 7.0 psi (flat or sloped ceilings) JOB: ADVANTAGE CONTRACTORS ADDRESS: 7412 176TH ST SW, EDMONDS (WEISS - COOK RESIDENCE) DESIGNER: KENNETH H. ROBINSON-ELMSLIE CALCULATIONS FOR 26 GPM FLOW (2 HEADS) IND. LOSS NET TOTAL A. WATER PRESSURE IN STREET 55.00 B: SELECT PIPE SIZE: 1" C: DEDUCT METER & SETTER LOSS (1") 12.00 43.00 DEDUCT BACKFLOW DEVICE LOSS (NONE) 0.00 43.00 D: DEDUCT HEAD LOSS FOR ELEVATION HEIGHT 30 X .434 LBS/FT 13.02 29.98 E. DEDUCT PRESSURE LOSS FROM MAIN TO SRINKLER 1-1/2" WATER SERVICE ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 150 1 150 ELLS: 8 2 16 R-TEES 7 3 21 B-TEES 3 2 6 TOTAL: 193 TOTAL EQUIVALENT FT. X .02 PSI/FT = 3.86 26.12 F: DEDUCT PRESSURE LOSSES FOR 1-1/2" PIPING FROM CONTROL VALVE TO MOST REMOTE SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 0 1 0 ELLS: 0 7 0 R-TEES 0 1 0 B-TEES 0 8 0 TOTAL: 0 TOTAL EQUIVALENT FT. X .0178 PSI/FT = 0 26.12 F: DEDUCT PRESSURE LOSSES FOR 1-1/4" PIPING FROM CONTROL VALVE TO MOST REMOTE SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 37 1 37 ELLS: 7 6 42 R-TEES 3 1 3 B-TEES 5 6 30 TOTAL: 112 TOTAL EQUIVALENT FT. X .0343 PSI/FT = 3.8416 22.28 F: DEDUCT PRESSURE LOSSES FOR V PIPING FROM CONTROL VALVE TO MOST REMOTE SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 12 1 12 ELLS: 3 5 15 R-TEES 2 1 2 B-TEES 1 5 5 TOTAL: 34 TOTAL EQUIVALENT FT. X. 1067 PSI/FT = 3.63 18.65 F: DEDUCT PRESSURE LOSSES FOR 3/4" PIPING FROM CONTROL VALVE TO MOST REMOTE SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 10 1 10 ELLS: 1 4 4 R-TEES 0 1 0 B-TEES 0 3 0 TOTAL: 14 TOTAL EQUIVALENT FT. X .0296 PSI/FT = 0.41 18.24 REMAINING PRESSURE FOR SPRINKLER OPERATION 18.24 CALCULATIONS PER NFPA 13D A.10.4.3 (A) (2013 ED.) WASHINGTON STATE a CERTIFICATE OF COMPETENCY PIKE PROTECTION SPRINKLER SYSTEM � Kenneth H. Robinson-Elmslie • • 7659-0106-CE Level 3 Robinson Plumbing, Inc. s; 110131 r72C2�� Explr s • 121311