Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED FIR RESUB 1-Fire Alarm Plan
Cascadia Electrical Solutions LLC 15226 20th PI W ES Lynnwood, WA 98087 (425) 493-3604 1 (844) 243-8237 info@cascadia-solutions.com PROJECT NARRATIVE Dayton Place — 540 Dayton Street 10/12/2021 RESUB Oct 21 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Cascadia Electrical Solutions LLC will be installing a new dedicated -function fire alarm system in the building located at 540 Dayton Street in Edmonds. This installation will consist of • An addressable dedicated function fire alarm panel and replacing existing smoke detectors with addressable • Installing an SLC riser loop to machine room • Taking over the existing zones as configured • Installing raceway and wiring for detection at each elevator lobby • Providing detection within elevator machine room • Providing primary, secondary, and hat relays • Installing an elevator pit heat for recall from pit level sprinkler riser The following corrections have been made to the design per plan review request: 1. Sprinkler riser location and monitor module have been indicated on the plans 2. Exterior horn strobe facing fire department arrival has been added 3. Lobby horn strobe has been added 4. Elevator pit and shaft have been detailed on the plans and sprinkler head is addressed on the plan set 5. A Knox box has been indicated on the plans Upon completion of installation and prior to inspection by the fire marshal, Cascadia Electrical Solutions LLC will perform a pre -test of the system to ensure functionality and compliance with applicable codes. Any and all changes requested by the fire marshal shall be adhered to in order to ensure compliance with local codes. Documents, permits, and inspection reports shall be kept on -site in an accessible location near the fire alarm control panel and will be made available upon request by any Authority Having Jurisdiction. Devin Dedman Project Manager Cascadia Electrical Solutions LLC devin@cascadia-solutions.com (360) 640-2922 SYSTEM INPUTS LOSS OF PRIMARY POWER ACTIVATION OF ALARM SILENCE SWITCH ACTIVATION OF MANUAL PULL STATION ACTIVATION OF SMOKE DETECTOR ACTIVATION OF TAMPER SWITCH ACTIVATION OF HEAT DETECTOR OPEN WIRE/GROUND IN CIRCUIT ACTIVATION OF WATER FLOW SWITCH ACTIVATION OF 2ND13RD FL SMOKE DETECTOR ACTIVATION OF GROUND FL SMOKE DETECTOR ACTIVATION OF ELEV MACHINE RM SMOKE DETECTOR 11-04-2021 PLAN REVIEW NOTES: Approved with condition: CONDTION: Sprinkler head is required to be installed in the pit. A normally opened monitored water control valve is also required. Please install the heat detector as well. DFM Burt 75CD 0 0 1 NAC1 WP 115CD v SYSTEM OUTPUTS SYSTEM RESPONSE V� 44 h� -r o 0 yAQr O C9 � O� 2 2 °Ar 'V -4�° °? 2 �° J �VQ 47 h0 4, 0 , .44 S �°J .1'. 11 h 2 y0� g 2 J0- � �� O� h� h� y� '0 a a v� A p A 5 47 � Q Q Q Q Q Q U° Q'T Q OPERATIONAL MATRIX AES RADIO FACP Approved D F M CIS I'%s -Lcrt South County Fire Date: 11 /04/2021 O Ci 1 SBC3 FAA 1 AUX1 y0 J1 Battery Calculations for Panel: FACP Part No:AFC50-AFC50, FACP, 50 POINT, 2 NACs Part No. QtT.1 Description I Standby Total Standby Alarm Total Alarm Panel Equipment AFCSO_MB 1 AFC-50MB 130.000OmA 130.000OmA 200.0000mA 200.000OmA Total Panel Stby 130.000OmA Total Panel Alarm 200.000OmA Peripheral Devices P2RK 1 HORN/STROBE, 2 WIRE, STANDARD CD, RED, OUTDOOR (Notification) 115CD 84dB 0.000OmA 0.000OmA 218.0000mA 218.000OmA P2RL 1 LSERIES 2-WIRE, HORN STROBE, RED, WALL (Notification) 75CD 88dB 0.000OmA 0.000OmA 119.000OmA 119.000OmA RA-6075 1 LCD REMOTE ANNUNCIATOR (Power) 20.000OmA 20.000OmA 25.000OmA 25.000OmA RA-6075 1 LCD REMOTE ANNUNCIATOR (Serial) 0.0000mA 0.000OmA 0.000OmA 0.000OmA PAD100-PD 5 PHOTO SMOKE SENSOR (Signaling line) 0.5000mA 2.5000mA 0.5000mA 2.5000mA PAD100-RM 4 RELAY MODULE (Signaling line) 0.2400mA 0.9600mA 0.2400mA 0.9600mA PAD100 HD 2 FIXED TEMPERATURE AND/OR SELECTABLE ROR HEAT SENSOR (Signaling line) 0.5000mA 1.00OOmAF 0.5000mA 1.000OmA PAD100-PSSA 1 ADDRESSABLE PULL STATION, SINGLE ACTION (Signaling line) 0.2000mA 0.2000mA 0.2000mA 0.2000mA PAD1WSIM 1 SINGLE INPUT MODULE (Signaling line) 0.2400mA 0.2400mA 0.2400mAj 0.2400mA Total Peripheral Stby 24.9000mA Total Periph Alarm 366.9000mA Total Standby Amps 154.9000mA Total Alarm Amps 566.9000mA Standby time: 24 Hrs 3.718Ah Alarm time: 5 Min 0.047Ah Battery requirement: 3.765Ah Compensation Factors - Standby: 1.2 Alarm: 1.2 Requirement with compensation: 4.518Ah Battery Calculations for Transponder: AES RADIO Circuit Calculations Panel: FACP Card: 00 Circuit:SBC3 Part No:7707P�8-ULPaVI -INTELLINET 2.0 FIRE SUBSCRIBER 8 ZONE, 7794A LOCAL ANNUN, MCT, RED Circuit Name: SBC3 Part NO. Q Description Standb Total Standb Alarm Total Alarm Circuit Type: Serial/RS-485 P-Link Terminal Voltage: 16V:DC Amperage: 1.000OA Panel Equipment Cable: 18/2 SOL JKT FPLR 1M RL RED #18 7707P-88-ULP-M MB 1 MOTHER BOARD 200.000OmA 200.0000mA 1.2000mA 1.2000mA Calculations based on Running Total Length. Total Panel Stby 200.0000mA Total Panel Alarm 1.2000mA Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 18°% Peripheral Devices Device Part No Appliance Desc Distance Current Volta a Volta a Drop Total Peripheral Stby 0.0000mA jotal Periph Alarm 0.0000mA AFC-50 Panel 001 RA-6075 LCD REMOTE ANNUNCIATOR 116'-0 0.0000mA Total Standby Amps 200.0000mAj TotalAlarmAmpsj 1.2000mA Circuit Calculations Panel: FACP Card: 00 Circuit:AUX1 Circuit Name: AUX1 Circuit Type: Power/Power limited Terminal Voltage: 24V:DC Amperage: 2.000OA Standby time: 24 Hrs 4.8Ah Alarm time: 5 Min OAh Battery requirement: 4.8Ah Compensation Factors -Standby: 1.2 Alarm: 1.2 Requirement with compensation: 5.76Ah I Cable: 1412 SOL JKT FPLR 1M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167"F Max. operating voltage drop: 18°% Device Part No Appliance Desc Distance Current Voltage Voltage Drop Circuit Calculations Panel: FACP Card: 00 Circuit:NAC1 Circuit Name: NAC1 AFC-50 Panel 24V Circuit Type: Notification Terminal Voltage: 20.4V:DC Amperage: 3.000OA 001 RA-6076 LCD REMOTE ANNUNCIATOR 116'-0 25.0000mA 23.9822V (0.0178V) Cable: 14/2 SOL JKT FPLR 1M RL RED #14 116'-0 25.000OmA Calculations based on Running Total Length. Total Current: 25.000OmA Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 18% (Total VDrop Percent:0.07%) Total Voltage Drop: 0.0178V Device Part No Appliance Desc Distance Current Voltage Voltage Drop Circuit Calculations Panel: FACP Card: 00 Circuit:SLC1 Circuit Name: SLC1 Circuit Type: Signaling line/Potter - SLC Terminal Voltage: 20.4V:DC Amperage: 1.000OA Cable: 18/2 SOL JKT FPLR 1M RL RED #18 Calculations based on Running Total Length. AFC-50 Panel 20.4v P2RK HORWSTROBE, 2 WIRE, STANDARD DID, RED, OUTDOOR, 115CD 67'-0 218.000OmA 20.2614V (0.1380V) 001 P2RL LSERES 24VIRE, HORN STROBE, RED, WALL, 76CD 46'-0 119.000OmA 20.2278V (0.0330V) 113'-0 337.000OmA Total Current: 337.0000mA (Total VDrop Pereent:0.84%) Total Voltage Drop: 0.1722V Design Criteria: Ambient temperature: 167"F Max. operating voltage drop: 18% Device Part No Appliance Desc Distance Current Voltage Volta a Drop AFC-50 Panel 20.4V 01 PAD100-PD PHOTO SMOKE SENSOR 7-0 0.5000mA 20.3999V (0.0001V; 02 PAD100-PSSA ADDRESSABLE PULL STATION, SINGLE ACTION T-0 0.2000mA 20.3997V (0.0002V, 11 PAD100-SIM SINGLE INPUT MODULE 20'-0 0.2400mA 20.3987V (0.001V; 03 PAD100-RM RELAY MODULE 36'-0 0.2400mA 20.3971V (0.0017V, 04 PAD100-RM RELAY MODULE 4'-0 0.24OOmA 20.3969V (0.0002V, CONDTION: Sprinkler head is 05 PAD100-RM RELAY MODULE N-0 0.2400mA 20.3967V (0.0002V, required to be installed in the 06 PAD100-RM RELAY MODULE 4'-0 0.2400mA 20.3966V (0.0001v; pit. A normally opened 07 PAD100-PD PHOTO SMOKE SENSOR 8'-0 0.5000mA 20.3964V (0.0002V, monitored water control valve 08 PAD100-HD FIXED TEMPERATURE AND/OR SELECTABLE ROR HEAT SENSOR V-0 0.5000mA 20.3962V (0.0001V; 09 PAD100-PD PHOTO SMOKE SENSOR 38'-00.5000mA 20.3956V (0.0006v, 10 PAD100-HD FIXED TEMPERATURE AND/OR SELECTABLE ROR HEAT SENSOR W-00.5000mA 20.3956V (0.0001V; is also required. Please install 134'-03.9000MA Total Current: 3.9000mA the heat detector as well. (Total VDrop Percent:0.02%) Total Voltage Drop: 0.0044V �--�' 19.90' 41 ' PARKING ' UNIT- 201 I L.C.E. ' PARKING � I , ' UNIT 202---- t L. C. E. 19.80' o ` 19.90' (0 �- A I PARKING UNIT 101 ,. LC.E. i O 1 SLC1 is 1812 F'iPLR A ' PA G T 102- in sec •o L C. E. 7 ch Le 115CD I ;O, 19.90' NAc1 wP 66.85' 17.00' 26. 5.85' 1 . •09tI C)t�J° CI(.R 8.90' f 0.15' V TO 1ST FLOOR SLC1 UP 15.35' STORAGE o of STORAGE in N 75CD HEAT DETECTOR IS IN ELEVATOR PIT ' NAC 1.001 I - - O 0 N GEN. S TORA GE o o 0 01,AUX1•g0 O 03 45' O O A 4 6.05' 6.05' 15.20' ELEV TO EQU1P. C. E. N GROUND FLOOR ELEVATOR EQUIPME T ROOM SCALE: 1/8" = 1' SLC1.07 135 S j SLCl-08F SLC1.05 SLCl-03 RELAY MODULES ARE CONNECTED TO THE FIRE HAT, SHUNT TRIP, PRIMARY ELEVATOR RM RM RM RM RECALL, AND SECONDARY ELEVATOR RECALL SLC1.06 SLC1.04 SUMMARY OF CONNECTIONS 1 SLC1 35.58' STORAGE STORAGE NIT 101) (UNIT 102) L' L. C. E. TELEPHONE UIP. ROOM C. E. NOTE: THERE IS NO SPRINKLER HEAD EXISTING INSIDE THE ELEVATOR SHAFT OR ELEVATOR PIT; HEAT DETECTOR ONLY FACP LOCATED IN RISER SPRINKLER RISER INSIDE ROOM RISER ROOM SLCl-01 S SLCl-11 FACP DAC AIM F SLCl-02 Ts F AI;, RM RM RM RM S R/F S O R/F 0 O� Ob •O� •00 •O^ o0 00 ,�O Ci Ci C 0 0 to t; 0 41 41 41 4O 41 41 LOVE OF DECK 1 s f f'_ ODOR Symbol Legend SYMBOL DESCRIPTION MANUFACTURER PART NUMBER QUANTITY FRCP AFC-50, FACP, 50 POINT, 2 NACs POTTER ELECTRIC SIGNAL AFC-50 1 QPHOTO SMOKE SENSOR POTTER ELECTRIC SIGNAL PAD100-PD 5 DAC INTELLINET 2.0 FIRE SUBSCRIBER 8 ZONE, 7794A, LOCAL ANNUN, MCT, RED AES CORP 7707P--88-ULP-M 1 FM RELAY MODULE POTTER ELECTRIC SIGNAL PAD100-RM 4 ®R/F FIXED TEMPERATURE AND/OR SELECTABLE ROR HEAT SENSOR POTTER ELECTRIC SIGNAL PAD100-HD 2 ADDRESSABLE PULL STATION, SINGLE ACTION POTTER ELECTRIC SIGNAL PAD100-PSSA 1 t LO# T 1 O7 • d L"T 101 DECK W T 202 DECK L.C.£ �J 63 : C E/I'T02 FROM GROUND FLOOR SLC1.��: o 1 s• !'S - O �' V-S C 1.13 -�a 6 FAA r WOCAL 1 SLC1 :18/2 FPLR UINI T ;01 62 90' 1st FLOOR PLAN " SCALE: 1/8" = 1' J) I L" T 702 Of Cr �11 c�wT adt F I R2021-0099 63 iC' LPT*f- 202 f DECK \ UNIT 10,E Sr~ YL&G4 T T NVEC AI, in i 0, o ?S 40' o - - o�h DO tit •ll l 13L 20' o s 1.12 4 h 14 75' S 2a 60' �r f WEPLACF FyPtICAi �I LOW T 207 AECx LG.f. } UNl T 201 SK r.JG" T rW'?CAt g LW T 2M 6s 50* ICr -r--- t._ C. £- 2n d OOR PLAN " FL SCALE: 1/8" = 1' J) RESUB Oct 21 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT J J z 0 H J 0 L/1 .J Q U I- U LLJ J LU Q 0 Q U V) Q X J 0 U J in 0 z z 0 0 W p Z J > coJ 0 0 U W Q 0 U Q Q Q N U p Q 0 o U) U N CIOU W J (0 z Uj Z Q J LO Q U (n Q U � 2 DATE: 10/13/21 W Q JIL W W F- Cn N CD 00 � z z 0 0 Q 0 � 0 0 2 0 z 2 ❑ Y W U ❑ ❑ z W = LU Y � m LU o 0 a m a Z Z �w ❑ z 0 w NICET CERTIFIED ENGINEER INFO: ENGINEER., DEVIN DEDMAN COMPANY.' CASCADIA ELECTRICAL SOLUTIONS LLC ADDRESS. 15226 20TH PL W LYNNWOOD, WA 98087 PHONE NUMBER. 360.640.2922 NICET INFORMATION: FIRE PROTECTION ENGINEERING TECHNOLOGY FIRE ALARM SYSTEMS #147961 LEVEL III SIGNATURE BLOCK SHEET NUMBER: FA1 (E)POTTER The Symbol of Protection Features • 50 addresses available on this analog addressable system • Additional system capacity achieved via multi -point SLC modules • 99 software zones • NFPA 72 Compliant Smoke Sensitivity Test Built -In • System Operates as Class A or Class B for SLC, P-Link and NACs • 5 Amp Power Supply, Expandable to 310 amps • 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188 • 2 Input/Output (1/0) Circuits for system flexibility rated at 1 Amp each • Strobe Synchronization and System Wide Sync for Gentex®, AMSECO®, Cooper Wheelock® and System Sensor® strobes • Dedicated Alarm, Supervisory and Trouble Relays • 4,000 Event History Buffer • Optional two line DACT with UD-2000 that can report General, Zone or Point Information • Built in IP Communicator • Ethernet Port for Programming and Network Connectivity • E-Mail System Status, Reports and Event Information • Product includes 5 year warranty. Description The AFC-50 is an analog/addressable fire alarm system with a total system capacity of 50 addresses. Additional capacity on the system is achieved using multi -point SLC modules. The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC). The AFC-50 has a 5 Amp power supply with two Notification Appliance Circuits (NACS) and two Input/Output (UO) circuits. The NACS are rated at 3 Amps each and the I/Os are rated at 1 Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Gentex, AMSECO, System Sensor and Cooper/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The NACS may be expanded using the PSN-1000 series intelligent power supplies. Each PSN-1000 adds another 10 Amps of power, 2 additional input circuits and the AFC-50 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN- 1000E has space to allow the installation of up to six expansion cards. The cards mount on a stacker bracket that allows access to all circuit connections. AFC-50 Fire Alarm Control Panel NYC Fire Dept. O F M Certificate of Approval p ° APPROVED 6256 ®ra . LISTED 7165-0328:0509 S735 Technical Specifications Dimensions 16"W x 17"H x 3 7/8"D AC Mains 3.0 Amps @ 120 VAC 50/60 HZ 2.0 Amps @ 240 VAC 50/60 HZ Enclosure 16 gauge cold rolled steel with removable locked door with Lexan viewing window Standby Current-130 mA Alarm Current-200 mA • 5 Amps power for NACS, I/O, and P-Link Battery 3 Amps per NAC, regulated • 1 Amp per VO circuit, regulated • Battery Charger range 8-55 Ali • Battery Charger voltage 27.3 VDC • P-Link maximum current of 1 Amp Temperature and 320 to 120° (0°C to 49°C) with a maximum Humidity Range humidity of 93% non -condensing. RESUB Oct 21 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830133 - REV E • 9/19 PAGE 1 OF 4 (E)POTTER The Symbol of Protection SLC Loop Accessories AFC-50 Fire Alarm Control Panel The control panel may be connected with up to 50 addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description Mh PAD 100-PD Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PAD 100-PHD Combination Analog Photo Electric Smoke/Heat Detector — a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135' Fahrenheit heat detector. PAD100-HD Analog Fixed (135d-185dF) or Rate -of -Rise Heat Detector (software selectable) PAD 100-DUCTR Addressable Duct Smoke Detector with Form C Relay. Addressable Duct Smoke Detector with Form C relay rated at 10a @ 250/120VAC or 8amps at 30VDC. PAD100-DUCT Addressable Duct Smoke Detector. PAD 100-6B 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors. PAD 100-4B 4" round base that may be mounted to an electrical box and wired for connection to the above sensors. PAD100-IB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. PAD100-RB Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. PAD100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. PAD100-CD Addressable CO gas detector. PAD 100-DD Addressable photo electric smoke detector for use in DUCT/DUCTR enclosure. PAD100-LFSB Addressable Low Frequency Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. The LFSB complies with the Low Frequency Signal Requirements (520 Hz) PAD100-SPYB Speaker base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1/8W to 4W. Modules Device Description Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PAD 100-MIM PAD100-PSSA Single Action Addressable Pull Station. PAD100-PSDA Dual Action Addressable Pull Station. PAD100-SIM Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box. PAD 100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PAD100-TRTI Two Relay Two Input module provides two form C relays that are individually controlled by the control panel. Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. Also provides two contact inputs. PAD 100-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PAD 100-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system. PAD 100-IM Isolater Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. PAD100-RM Relay Module that provides one form C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. PAD 100-LED Module provides a single addressable LED that is controlled by the control panel. PAD 100-SM Speaker Module provides switching for two audio channels. PAD 100-LEDK Addressable LED and key switch that mounts in a single gang box. PAD 100-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised. For use with the PAD 100-DUCTR only. PAD100-OROI One Relay One Input Module provides one form C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830133 - REV E • 9/19 PAGE 2 OF 4 (E)POTTER The Symbol of Protection SLC Features The Potter protocol is a digital protocol with a proven design for reliability and noise immunity. The system does not require special cable or conductors for connection of the Signaling Line Circuit as long as the cable is compliant with NFPA 70 and NFPA 72. The system allows for Class A or Class B installations as well as "T-Taps", with a max wiring distance of 10,000 Ft. Sensor Features The sensors through the fire alarm control panel provide a real time status as to the condition of the system. The smoke detector sensitivity, heat detector temperature level and drift compensation are all programmable options. The system also allows for a day/night mode where the panel automatically adjusts the sensitivity depending on the time of day. To assist in the reduction of false alarms, the smoke detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the point that it can no longer maintain the programmed sensitivity. User Interface The fire alarm control panel has a 2 x 16 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LEDs: • AC Power - Green • Alarm - Red • Earth Fault - Amber • Supervisory - Amber • Silenced - Amber • Trouble - Amber • Pre -Release - Amber • Release - Red The common buttons include a Silence, Reset, Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. P-Link The AFC-50 has a proprietary communication protocol that communicates through a RS-485 connection to field devices. Up to 32 devices may be connected to a single P-Link connection. The P-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: PAD100-SLCE-Analog/Addressable loop expansion module RA-6075R — 2 x 16 LCD annunciator with a key pad in a locked metal enclosure. AFC-50 Fire Alarm Control Panel RA-6500R(F) — 4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version available. LED-16(F) — 16 LED annunciator with common indicators in a locked metal enclosure. Flush mount version available. PSN-1000(E) — 10 amp, remote intelligent power supply with 6 NACs, 2 Inputs and a P-Link repeater. This panel is listed in conjunction with the AFC-50 as releasing circuits. CA-6075 — Class A convertor that converts the SLC, NACs and P-Link connection UD-2000 — UL listed, Dual line telephone alarm communicator DRV-50 — LED driver expander, used to connect up to 50 LEDs in a graphic display FCB-1000 — Fire communication bridge, provides remote mounting of the Ethernet connection FIB-1000 — Fiber interface module, used to extend P-Link to multi - mode fiber (2 required) RLY 5 — Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC SPG-1000 — Serial parallel gateway, allows for the connection to a serial or parallel printer The FIB-1000, FCB-1000 and the SPG-1000 may be installed in the stacker bracket or ordered with the optional rack mount enclosure. MC-1000 Multi -Connect allows up to sixty-three AFC series panels to share a single reporting technology. IDC-6 — Initiating device circuit provides 6 programmable inputs AE-2 — Two card expansion cabinet AE-8 — Eight card expansion cabinet AE-14 — Fourteen card expansion cabinet Ethernet/I.P. Connection The AFC-50 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The IP communicator is listed to report to the UL listed Sur -Gard III IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830133 - REV E • 9/19 PAGE 3 OF 4 (E)POTTER The Symbol of Protection Dimensions IN 00 II O 0 LEFT SIDE Ordering Information AFC-50 Fire Alarm Control Panel © O TOP DEPTH = 3.75 " 0 0 DOOR = 16.07" BACKBOX = 15.77" DEPTH = 3.84" BOTTOM Model Description Stock No. AFC-50 Fire Alarm Control Panel 3992752 Replacement Board AFC-50 3992756 II 0 C) C) RIGHT SIDE DWG #5931 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830133 - REV E 9/19 PAGE 4 OF 4 'W�4" ,, ES,�� of SECURITY CORPORATION INNOVATION 7707 Fire Subscribers IntelliNet A Newer, Smarter Alarm Communications Platform Feature Highlights • Leverages state of the art technology • Applies advanced security protection • Offers flexible power and configuration options • Engineered for backward compatibility with legacy systems • Enables future ready capabilities • Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button • Includes robust Multiple Communication Technologies (MCT) feature • Emulates virtual keypad • Improves functionality with an adaptive Graphic User Interface (GUI) for programming via smartphones, tablets and PCs • Plus many more... Key Benefits M AU 1-1(90NNFPALISTED • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks • Protects subscriber units against unauthorized access and rogue activity with a password -protected Dealer Code • Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-IntelliPro full data module • Provides versatile power options: (1) Direct from the Fire Alarm Control Panel (FACP) without requiring an electrician onsite and without Subscriber backup battery; (2) Directly from the FACP with Subscriber backup battery; or (3) Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network. The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data module option, they are the ideal drop -in replacement for Plain Old Telephone Service (POTS) lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status. The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop, tablet, or integrated Universal Serial Bus (USB)—without the need for special cables or having to use a handheld programmer. Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network D) BurglaryD _ Subscriber — — — — — — — — — lam B ♦ 1 1_1 _ C ♦ I N B) Fire / N i Subscriber 1 1 I AES-Network Management System D — — — B _ _ _ _ _ — — — — — — — — 705BE �— — — PrimaryAES-MultiNet Receiver I ♦ �� I I ♦ I A) Alarm Panel Secondary AES-MultiNet Receiver ♦ I ♦ 1 I •• B ♦♦ E B Alarm Automation A — _ — _ _ I C)IP Links Customer Location I Mesh Radio Technology I Central Monitoring Station Alarm Panel & AES Subscriber Multi -path AES-IntelliNet@ Network Primary & Secondary AES-MultiNet System sends critical event signal delivers alarm signals via smart routing receives transmission in 1-3 seconds The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add -on accessory board. AES subscribers' intelligent software automatically detects new hardware and devices to reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming. A laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units. A FACP Power Supply Adapter is required for certain configurations when using flexible power options. The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians to get in, out, and on to the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: aes-corp.com/products/fire/fire-marshal-resources How to Order 7707 Fire InteffiNet 2.0 Fire Subscribers 2.0 PREMIUM (UL & ULC Listed) 7707P-88-M IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies (MCT), Red Enclosure 7707P-88-ULP-M IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707P-44-M IntelliNet 2.0 Fire Subscriber, 4x4 Zone (4 Reversing Polarity, 4 Supervised) with Multiple Communication Technologies (MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber, 4x4 Zone (4 Reversing Polarity, 4 Supervised) 7707P-44-ULP-M with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 2.0 ACCESSORIES 7794A Standalone AES-IntelliPro Fire full data module add -on accessory board with firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-way Junction Box Legacy. .- 7706-ULF Integrated Fire Monitoring System, Red Enclosure 7788F-ULP-P Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro (7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7788F-ULP Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7788F Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure Legacy Fire Subscriber, 4 Zone with 7795 AES-IntelliPro (7794 full data module, 7744F-ULP-P 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7744F-ULP Legacy Fire Subscriber, 4x4 Zone, 4 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7744F Legacy Fire Subscriber, 4x4 Zone, 4 Reversing Polarity, 4 Supervised Zones, Red Enclosure LEGACY ACCESSORIES 7794 Standalone AES-IntelliPro Fire full data module add -on accessory board for legacy units only, please see 7794A above for IntelliNet 2.0 version Technical Specifications 7707 Fire DIMENSIONS 13"H x 8.5"W x 4.5"D (33cmH x 21.5cmW x 11.4cmD) WEIGHT 5.8 Ibs (2.6 kilograms) excluding battery 13 Ibs (5.9 kilograms) with 10 Ah battery RADIO FREQUENCY Standard Frequency Range: 450-470 MHz Contact AES for other UHF and VHF frequencies ANTENNA 2.5 dB tamper resistant antenna included, mounts on enclosure Optional remote mounting antenna available POWER INPUT AC SOURCES Transformer: Class 2 16.5V AC nominal output 1.9 A max current (40 VA MIN) ELK ELK-TRG1640, MG ELECTRONIC SALES MGT1640, or AES 1640 (not included) DC SOURCES (includes FACP) 24V DC Regulated Power Supply with Subscriber Rechargeable Battery 1.9 A max current BACKUP BATTERY 10-12 Ah, UL recognized lead acid gel cell, size based on subscriber configuration Contact Us ALARM SIGNAL INPUTS/ZONES 8 individually programmable E.O.L. type zone inputs 4+4: 4 reverse polarity input and 4 individually programmable E.O.L. type zone inputs Optional 7794A AES-IntelliPro for full data via Contact ID, Pulse, Modem Ile and Modem IIIa2 UL LISTINGS UL 864 loth Edition Standard for Control Units and Accessories for Fire Alarm Systems ULC S559-04 1st Edition Equipment for Fire Signal Receiving Centres and Systems TROUBLE OUTPUT—ACK DELAY/ANTENNA CUT Form C relay, fail secure, rated 24V DC 1A resistive, unsupervised RESET BUTTON Located on main circuit board OPERATING TEMPERATURE 32 to 120°F (0 to 49°C) STORAGE TEMPERATURE 14 to 140°F (-10 to 60°C) RELATIVE HUMIDITY 0 to 93%, non -condensing RECHARGE CAPABILITY Will charge 12V battery size from 10-12 Ah PORTS Ethernet for configuration and message communication USB access for software upgrade REMOTE ANNUNCIATOR AES Model 7740 Remote Annunciator, supervised COMPATIBLE RECEIVERS 7705i AES-MultiNet Receiver CONFIGURATION INTERFACE Web browser capable device accessible via smartphone, tablet, laptop, or PC CURRENT CONSUMPTION Standby w/ charged backup battery: 200 mA (1.2 A Transmitting) Standby + charging backup battery: 900 mA (1.9 A Transmitting - MAX) POWER OUTPUT 2 or 5 Watts Factory set ENCLOSURE MATERIAL Steel with paint finish FINISH COLOR Red VISUAL INDICATORS Front panel LCD (2 x 20 alphanumeric character backlit display) Power and Trouble LEDs (ALM, Trouble, Tx, Rx, WA) For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com. (E)POTTER The Symbol of Protection Features • One (1) Form C relay contact • SLC Class A, Class X & Class B • Mounts in a standard 4" or double gang box • Wiring terminals accessible when mounted in box • All wiring terminals accept 22 to 12 AWG • Product includes a 5 year warranty • UUKL Listed for Smoke Control Description The PAD 100-RM uses one (1) SLC loop address to provide one (1) Form C relay contact. The module mounts on either a 4" square or double gang box. The PAD 100-RM includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. Application The PAD 100-RM is compatible with Potter's IPA and AFC/ARC series addressable fire alarm control panels. The PAD100-RM is an interface module providing one (1) Form C relay contact. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the PAD100-RM. The PAD 100-RM uses a single device address to identify relay contacts. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: 1. Power to the device is removed. 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. PAD 100-RM Relay Module -C MB/ + + f i2 NE J © POTfER FM ( U` APPROVED Technical Specifications Operating Voltage 24.OV Max SLC Standby 240µA Current Max SLC Alarm 240µA Current Relay Contacts 2A @30VDC, 0.5A @125VAC Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non -condensing) Max no. of Module Per 127 units Loop Dimensions 4.17" (106mm)L X 4.17" (106mm)W x 1.14" (29mm)D Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.6 lbs Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830084 - REV D 12/18 PAGE 1 OF 2 (E)POTTER The Symbol of Protection Installation Using Compatible Electrical Box Fig 1 Wiring Diagram PAD] 00-RMRelay Circuit Fig 2 FROM FACP OR PREVIOUS MODULE TO NEXT MODULE SYl4VHN O ® ,Y ONE (1)FORM C i RELAY CONTACTS o —NC M 0 0 0 0 o ®PO= o 0 PA IOPNM 0 PAD 100-RM Relay Module It is possible that the internal relay in the PAD100-RM may be shipped in the non -normal / activated state. To ensure that the internal relay is set to the normal state, connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output. Ordering Information Model Description I Stock No. PAD100-RM Relay Module 13992705 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830084 - REV D • 12/18 PAGE 2 OF 2 (E)POTTER The Symbol of Protection Features • Single or Dual Action versions • Durable die-cast construction • Reset key matches the fire alarm control panels • Compatible with IPA Series panels • SLC Class A, Class X & Class B • Product includes a 5 year warranty • UUKL Listed for Smoke Control Description The PAD100-PSSA (Single Action) is activated by simply pulling the white "T" bar handle down. The PAD100-PSDA (Dual Action) is activated by lifting the front cover and then pulling the white "T" bar handle down. Once activated, the "T" bar cannot be reset without opening the front cover. Opening the front cover will also activate the pull station. To reset the PAD 100-PS Series, use the Potter WS-93 key to unlock and open the front cover. Once the cover is open, push the "T" bar back into the normal position and re -secure the front cover. Application The PAD 1 00-PSSA/PSDA is compatible with Potter's IPA and AFC/ ARC series addressable fire alarm control panels. It is a non -coded addressable pull station available in either a single or dual action model and installs on a single gang box or surface mounts using the P32-BB or P32-DBB (deep) back box. PAD 100-PSSA/PS DA Addressable Pull Station Single/Dual Action �RO U`9�R . w<AP(� Technical Specifications Operating Voltage 24.0 VDC Max SLC Standby Current 200uA Max SLC Alarm Current 200uA 32°F - 120°F (0° - 49°C) Environmental Limitations Indoor Only Dimensions 4.75" H x 3.25" W x 1.75" D Relative Humidity Range 0 - 93% (non -condensing) Single gang box or Mounting Options Potter P32-BB/DBB APS-SA - 1.22 lbs. [ZppingWei t APS-DA - 1.46 lbs. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830097 - REV D • 12/18 PAGE 1 OF 2 PAD 100-PSSA/PSDA (E)POTTER Addressable Pull Station The Symbol of Protection Single/Dual Action Setting the Address The PAD 100-PS Series uses one SLC address assigned to the device. The address is set using the DIP switch located on the back of the PAD 100-PS device. Pull Station Front View Fig 1 o-_ Hn c jz p U ©PorTER PAD100-PSDA Pull Station Back View and Wiring Fig 2 FROM FACP OR PREVIOUS DEVICE TO NEXT DEVICE Ordering Information 0 Model Description Stock No. PAD100-PSSA Addressable Pull Station, Single Action 3992721 PAD100-PSDA Addressable Pull Station, Dual Action 3992720 U POTTER PAD 100-PSSA WIRED CONTACTS 0 0 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830097 - REV D • 12/18 PAGE 2 OF 2 (E)POTTER The Symbol of Protection Features • Low profile, less than 2 inches with the base • Wide selectable sensitivity range of 1.0 to 3.7%/foot • Sensor communicates sensitivity to control panel • UL listed smoke calibration and sensitivity • Optional locking tab to prevent unwanted removal • Simple DIP switch address setting, no programming tool required • LED alarm indicator • Product includes a 5 year warranty • UUKL Listed for Smoke Control Description The Photoelectric Smoke Sensor is a listed Analog Addressable smoke sensor compatible with fire alarm control panels that utilize the Potter Addressable Device (PAD) protocol. The PAD 100-PD is a low profile smoke sensor with a wide sensitivity range. The sensor and base (not included) are made of a durable plastic in an off-white color to blend in with the ceiling. The PAD 100-PD has a sensitivity range of 1.0 to 3.7 % per foot and is UL. The PAD100-PD features drift compensation and has built in dirty detector warning as well as. The PAD 100-PD and the control panel communicate over a proven and robust digital communication path and the system analyzes the information at the particular device. The total polling speed is less than five (5) seconds, well under the UL requirements. The sensor is compatible with any of the PAD series sensor bases and simply twists on. The PAD100-PD is addressed using DIP switches in the rear of the sensor and can be easily programmed in the field without special tools. Setting the Address Each addressable device on the SLC loop must have a unique address from 1 to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device. Verify the following: 1. Power to the device is removed 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. PAD100-PD Photoelectric Smoke Sensor QySEMB�SO • W R�yTHE VyP 4r O � FM =, U� APPROVED LISTED Technical Specifications Operating Voltage 24 VDC Detector Current Draw 300 µA Alarm indicator 1 LED Alarm set -point range 1.0 to 3.7 %/ft 3.6-12 %/m Installation temperature 32 to 120 ° F / 0 to 49 ° C range Operating relative 0% to 93% (Non -condensing) humidity range Start-up time Max. 1 sec. Maximum number of 127 addresses per loop Maximum number of lighted indicators in 30 alarm per loop. Color Eggshell White Weight (without base) 101g (3.56oz) Dimensions (without Height: 1.35 in (34mm) base) Diameter: 3.93 in (100 mm) Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830108 - REV D • 12/18 PAGE 1 OF 2 (E)POTTER The Symbol of Protection Air Velocity Ratings The PAD100-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. PAD100-PD Photoelectric Smoke Sensor The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on, the PAD100-PD will operate even though the LED may not illuminate. Operation The PAD 100-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit (SLC) of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled. The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is in an active status. The polling LED can be turned off if desired for less conspicuous operation. The PAD 100-PD with the PAD100-4DB or PAD100-6DB has a low profile of less than two (2) inches to blend into the surrounding environment. The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector. Sensor Sensitivity The PAD100-PD and the compatible control panel work in tandem to keep the sensitivity consistent. As the sensor is installed over time, the sensor compensates for the dirt in the unit until it is out of range. At that time, the panel will indicate a dirty sensor. The sensor will then have to be cleaned or replaced. The PAD 100-PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for intervention prior to the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs. NOTE. As required by NFPA, do not install the sensors until all construction is complete and the work area has been thoroughly cleaned. If the sensors have been installed in a construction environment, they should be cleaned or replaced before the system is placed into service. Spacing The PAD100-PD is UL listed with a recommended maximum spacing of 30 feet. Refer to NFPA 72 for specific information regarding detector spacing, placement and special applications. Compatible Bases All bases will mount on a single gang, double gang, octagon, 4" square or mud ring electrical box. Device Description Stock No. PAD100-4DB 4" Standard Base 3992731 PAD100-6DB 6" Standard Base 3992732 PAD100-IB 6" base with an isolator module included. 3992730 PAD100-RB 6" base with one Form-C relay contact. 2A @ 30VDC, 0.5A @ 125VAC 3992728 PAD100-SB 6" base with sounder module included. Sound pattern is provided from external source. 3992729 PAD100-SPKB 6" base with speaker included 3992762 Ordering Information Model Description I Stock No. PAD100-PD Photoelectric Smoke Sensor 3992733 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830108 - REV D • 12/18 PAGE 2 OF 2 (E)POTTER PAD100-HD The Symbol of Protection Heat Detector Features P�SEMB�Fo • Selectable Rate of Rise and/or Fixed Heat Detector �P i2 THE J`' • Low profile ■IC Qy • Reliable detection technology • LED Alarm Indicator • Ambient temperature listing of 32' F to 150' F • Simple DIP switch address setting, no programming tool required + l� • Product includes a 5 year warranty • UUKL Listed for Smoke Control Description The PAD100-HD is a listed Analog Addressable rate of rise and/or fixed temperature heat sensor compatible with any fire alarm control panel that has the Potter Addressable Device (PAD) protocol. The heat sensing portion utilizes a proven thermistor for accurate and reliable heat detection. The sensor and base (not included) are made of a durable plastic in an off white to blend in with the ceiling. The PAD100-HD is UL listed with a selectable fixed temperature point from 135' to 185' Fahrenheit and can be used for rate of rise applications. See detector spacing limitations below. This flexibility allows the installer to cover a wide variety of applications with a single unit. The PAD100-HD and the control panel communicate over a proven and robust digital communication path and the system analyzes the information at the particular device. The total polling speed is less than five (5) seconds, well under the UL requirements. The sensor is compatible with any of the PAD series sensor bases and simply twists on. The PAD 100-HD is addressed using DIP switches in the rear of the sensor and can be easily programmed in the field without special tools. Setting the Address Each addressable device on the SLC loop must have a unique address from 1 to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device. Verify the following: 1. Power to the device is removed 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. FM =, U� '� APPROVED LISTED Technical Specifications Operating Voltage 24 VDC Detector Current Draw 300 µA Alarm indicator 1 LED Alarm set -point range 135 to 185 'F/ 57 to 85 °C Rate of Rise Detection 150F/min. (8.3'C/min.) (Selectable Option) Installation temperature 32 to 150 OF / 0 to 66 °C range Operating relative 0% to 93% (Non -condensing) humidity range Start-up time Max. 1 sec. Maximum number of 127 addresses per loop Maximum number of lighted indicators in 30 alarm per loop Color Eggshell White Weight (without base) 82g (2.89 oz) Dimensions (without Height: 1.94 in (49mm) base) Diameter 3.93 in (100mm) Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830110 - REV E • 6/20 PAGE 1 OF 2 (E)POTTER The Symbol of Protection Operation PAD100-HD Heat Detector The PAD 100-HD is an analog addressable sensor that uses one address on the Signaling Line Circuit (SLC) of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled. The LED flashes every time the unit is polled and will flash at a fast rate if the unit is in an active status. The polling LED can be turned off if desired for less conspicuous operation. The PAD 100-HD with the PAD 100-4DB or PAD 100-6DB has a low profile to blend into the surrounding environment. The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on, the PAD100-HD will operate even though the LED will not illuminate. Spacing The ANSUUL listed spacing limitations of PAD 100-HD smooth ceiling are dependent on alarm set point. Alarm Set -Point Rate of Rise Spacing Fixed Temperature Spacing 135°F to 160°F Max. 70 ft. Max. 70 ft. (57°C to 71°C) 161°F to 1747 Max. 60 ft. Max. 60 ft. (72°C to 79°C) 175°F to 185°F I Max. 15 ft. I Max. 15 ft. (80°C to 85°C) Compatible Bases All bases will mount on a single gang, double gang, octagon, 4" square or mud ring electrical box. Device Description Stock No. PAD100-4DB 4" Standard Base 3992731 PAD100-61)B 6" Standard Base 3992732 PAD100-I13 6" base with an isolator module included. 3992730 PAD100-RB 6" base with one Form-C relay contact. 2A @ 30VDC, 0.5A @ 125VAC 3992728 PAD100-SB 6" base with sounder module included. Sound pattern is provided from external source. 3992729 PAD100-SPKB 6" base with speaker included 3992762 Ordering Information Model Description I Stock No. PAD100-HD Fixed Temperature Heat Sensor 3992735 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830110 - REV E • 6/20 PAGE 2 OF 2