SI report 2POST -INSTALLED ANCHORS REPORT MAYES lrerraclon Report Number: M7211251.0002 Service Date: 06/01/21 Report Date: 06/04/21 20225 Cedar Valley Rd Ste 110 Lynnwood, WA 98036-6365 425-742-9360 Client Project Andersen Construction BAC Edmonds Renovation Attn: Vante Johnson 306 Main St 5601 6th Ave S. Ste 550 Edmonds, WA Seattle, WA 98108 Proiect No.: M7211251 Permit No.: BLDG-2020-0469 Samples: N/A Weather: Indoors CORRECTIVE ACTION TAKEN On site for a follow up inspection to field report M7211251.0001, dated 05/26/2021, stating missing anchor not installed due to reinforcing steel interference in the cold form steel wall at Passenger Room 102. Received the attached documentation from Gensler -Don Henning with ASI Structures -Don Fuller approved fix to add a new A3C wall aligned with the edge of the door frame and insert a new Simpson Strong bolt 2 (1/2x 3-3/4" ) at the jamb for anchoring the cold form steel base track. Observed satisfactory installations and bolt torque at 60 foot- pounds with effective embedment at 2-3/4". Installation of this anchor clears Mayes Terracon field report M7211251.0001, dated 05/26/2021. To the best of our knowledge, the items inspected today are in conformance with approved plans and specifications. Services: Special Inspections / Materials Testing Mayes/Terracon Rep.: Todd Wirtz Reported to: Andersen Construction Contractor: Andersen Construction Report Distribution: (1) Andersen Construction, Vante (1) City of Edmonds WA, Pat Lawler Johnson (1) Jones Lang LaSalle Americas, Inc., (1) M Arthur Gensler Jr & Associates Maria Arsanto Inc, Don Henninq (1) Mayes Testing Engineers, Inc, Barry Tuttle Reviewed By: 4- Barry Tuttle Project Field Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CT0001, 10-16-13, Rev.10 Page 1 of 1 ' 08 The hold down for this door stud is the one that is#led. It has the rebar right under ' A it 2" down. We are ' not able to get the t02 bolt to grab. The rebar runs under the wall line the whole 3'-3" length of it II � PASSAGE