FIR2021-0141+Fire_Alarm_Equipment_Specification_Sheets+12.7.2021_11.14.37_AM+2557573
PSG 6 Amp and 10 Amp, 24 Volt Power Supplies The PS Series are independently configurable power supplies, allowing you to pair any input with any output, and feature LED diagnostics for troubleshooting. The PS Series is a remote power supply line from Silent Knight and is a direct replacement for the 5495/5499. The SK-PS6 is a 6 amp and the SK-PS10 is a 10 amp, remote power supply with battery charger that maybe connected to any 12 or 24 volt fire alarm control panel (FACP) or used as a standalone power supply. The PS Series provides 24 VDC power for NACs (notification appliance circuits) configured as either Class B or Class A (requires the ZNAC-PS option card) with multiple sync protocol options. The PS Series also provides auxiliary power, constant or resettable, suited for detectors, annunciators, door holders, and other fire alarm system peripherals. The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet. FEATURES AND BENEFITS • Up to five (6 amp model) or seven (10 amp model) independently -configurable, power - limited output circuits for: —Class B and/or Class A NACs —Class B and/or Class A resettable or non- resettable 24V auxiliary power —door holder power • Converts from Class B to Class A wiring without losing any outputs using the ZNAC- PS converter card (sold separately) • Optimal for powering four -wire smoke detectors, annunciators, and other system peripherals requiring regulated power • Optional addressable control, monitor, and relay modules and power -supervision relay (EOLR-1) • Configurable for ANSI° Temporal 3 or Temporal coded output • UL-Listed NAC synchronization using System Sensor®, Wheelock', Gentex°, or AMSECO° appliances • Synchronization can be triggered from FACP NAC/remote sync outputs, cascaded power supply, or a control module, single or multi, which may be housed within the power supply cabinet • Ability to cascade up to four power supplies • Two (6 amp model) orthree (10 amp model) fully -isolated input/control circuits which can be programmed to any output • Two Form C normally -closed trouble relays for AC Trouble and General Trouble • 6 or 10 amp full load output, respectively, with 3 A maximum/circuit • Individual NAC power and trouble LEDs for diagnostic efficiency • Trouble history mode for diagnostic support • Wide range end -of -line supervision value (normal: 2-27K ohms) • Selectable earth fault detection (enable or disable) • AC trouble report delay timer • Completely configurable via onboard DIP switches, no extra software required • Self-contained in compact, locking cabinet constructed of heavy gauge steel with a I91:441YAMIE11 RECEIVED Dec 07 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT A corrosion -resistant powder coat chip and scratch -resistant finish • Cabinet designed with ten double knockouts and a removable door for ease of installation and wiring • Includes integral battery charger capable of charging up to 33 AH batteries • Cabinet can house two 7 AH or 18 AH batteries • Battery charger may be disabled via DIP switch for applications requiring larger batteries and external battery charger • Removable terminal blocks accommodate up to 12 AWG (3.1mm2) wire • Works with any UL 864 FACP which utilizes an industry -standard reverse -polarity notification circuit Honeywell SILENT' KNIGHT ORDERING INFORMATION SK-PS6: 6.0 A,120 VAC remote charger power supply in a lockable, metal enclosure, red SK-PS10:10.0 A,120 VAC remote charger power supply in a lockable, metal enclosure, red ZNAC-PS: Optional Class A converter card, sold separately SK-CONTROL: Addressable Control Module for one Class B or Class A zone of supervised, polarized Notification Appliances. Notification Appliance Circuit option requires external24 VDC to power notification appliances. SK-RELAY: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch SK-MONITOR: Addressable Monitor Module for one zone of normally open dry -contact initiating devices. Includes plastic cover plate and end -of -line resistor. Module may be configured for either a Class B or Class A SK-MONITOR-2: Dual Monitor Module. Same as SK-MONITOR except it provides two inputs for Class B wiring only SK-RELAYMON-2: Provides two monitored inputs and two Form-C relays. Functions in Class B wiring only SK-CONTROL-6: Six -circuit supervised control module SK-RELAY-6: Six Form-C relay control module EOLR-1:12/24 VDC end -of -line relay for monitoring four -wire smoke detector power BAT-1270-BP: Battery,12 volt, 7.0 AH, 5-pack (two required) BAT-12180-BP: Battery,12 volt,18AH, 2-pack BAT-12330: Battery,12 volt, 33AH SEISKIT-MULTI-1: Seismic kit for the PS Series. Includes bracket and hardware for two 7AH or two 18AH batteries. Page 2 of 3 — SK-61095:C • 3/10/2021 SK-PS6 / SK-PS10 TECHNICAL SPECIFICATIONS PRIMARY (AC) POWER SK-PS6:120 VAC, 50/60 Hz, 5.OA maximum SK-PS10:120VAC, 50/60 Hz, 6.2 A maximum Wire Size: #12-14 AWG with 600 V insulation COMMAND INPUT CIRCUIT Trigger Input Voltage: 9 to 32 VDC Trigger Current: 2.0 mA (16 - 32 V); Per Input:1.0 mA (9 -16 V) RELAY CIRCUITS Trouble Contact Rating: 4 A at 24 VDC OUTPUT CIRCUITS • 24 VDC filtered • SK-PS6: T138-TI39 — lA Regulated, 3A special applications; TB10-TB12 — 0.3A Regulated, 3A special applications • SK-PS10: T138-TB11-1.5A Regulated, 3A special applications; TB12-TB14 — 0.3A Regulated, 3A special applications • 6.0A (SK-PS6) or 10.0 (SK-PS10) maximum total continuous current for all outputs Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.sitentknight.com SECONDARY POWER (BATTERY) CHARGING CIRCUIT • Supports lead -acid batteries only • Float -charge voltage: 27.6 VDC • Maximum current charge:1.5 A • Maximum battery capacity: 18 AH (inside cabinet) • Maximum battery charging capacity: 33 AH (external cabinet) PHYSICAL Dimensions: 20.0"H x 14.5°W x 3.5"D (cm: 50.8H x 36.83W x 8.9D) Weight: with two 7Ah batteries is 24 pounds (10.9 kg), with two 18 AH batteries is 39 pounds (17.7 kg) STANDARDS AND CODES The SK-PS complies with the following standards: NFPA 72: National Fire Alarm Code UL 864: Standard for Control Units for Fire Alarm Systems (NAC expander mode) UL 1481: Power Supplies for Fire Alarm Systems AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S3511 CSFM: 7315-0559:0522 FDNY Approved FM Approved SK-61095 I C 1 03/21 ©2021 Honeywell International Inc. Honeywell SILENT' KNIGHT 4,�� SYSTEM Photoelectric Smoke Detectors System Sensor i3- series smoke detectors represent significant advancement in conventional detection. The i3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features • Plug-in detector line, mounting base included Large wire entry port • In -line terminals with SEMS screws • Mounts to octagonal and single -gang back boxes, 4-square back boxes, or direct to ceiling • Stop -Drop 'N Lock attachment to base • Removable detector cover and chamber • Built-in remote maintenance signaling Drift compensation and smoothing algorithms • Simplified sensitivity measurement • Wide-angle, dual -color LED indication • Loop testing via EZ Walk feature • Built-in test switch Agency Listings & F M X MEA MSFMWs LISTED APOapproved approved c 5911 3011446 7272-1653:152 290-01 " 313C93? Installation ease.The i3 line redefines installation ease with its plug-in design.This allows an installerto pre -wire bases (included with heads). The large wire entry port and in -line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug into the base with a simple Stop-Drop'N Lock' action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED - indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i3 protocol. The SENS-RDR, a wireless device, displays the sensitivityof i3 detectors in terms of percent -per -foot obscuration. Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out -of -sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, the EZ Walk loop test feature is available on 2-wire P detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. (-L3) Smoke Detector Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 1357 (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single -gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre -wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent -per -foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual - color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 12/24V non -polarized Minimum: 8.5 V Maximum: 35 V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 NA maximum average; 4-wire: 50 NA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V, 23 mA @ 24 V Peak Standby Current 2-wire: 100 uA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30 V AC/DC Physical Specifications Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 1207 (0°C to 49°C); 2WT-B and 4WT-B: 327 to 1007 (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non -condensing Thermal Sensor 1357 (57.2°C) fixed Freeze Trouble 2WT-B and 4WT-B only:417 (5°C) Sensitivity 2.50/o/ft nominal Input Terminals 14 to 22 AWG Mounting LED Modes 3'/2-inch octagonal back box 4-inch octagonal back box Single -gang back box 4-inch square back box with a plaster ring Direct mount to ceiling Power -Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal 2W-B No Wiring Alarm Current 2-wire 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24 V 4WT-B Yes 4-wire 20 mA @ 12 V, 23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter f_ SYSTEM �/ SENSOR m2cha System Sensor. 3825 Ohio Avenue • St. Charles, L 60174 Product specifications subjec[to009 System Sensotice.Vsit rystemsensoccom for Phone:800-SENSOR2•Fax:630-377-6495 urrentproductinformat5-03180i7-6/09latest version okhisdata sheet. A06-0318-007.6/09•#2169