Loading...
Singleton SFR - DFR 5-18-21& ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION May 14, 2021 Mr. Keith Singleton (E-Mail) 508 2nd Avenue N. Edmonds, WA 98020 RE: CONSTRUCTION TESTING AND INSPECTION Singleton SIR 508 2°d Avenue N. Edmonds, Washington Dear Mr. Singleton, KA No. 096-21213 Permit No. BLD2021-0279 In accordance with your request and authorization, our firm performed construction testing and inspection for the above -referenced project. The sampling and testing was performed by our inspectors and reports are included. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office. Respectfully submitted, KRAZAN & ASSOCIATES, INC. CCorb4ti W. Mercer Project Manager/Lab Manager Pacific Northwest Division CWM/lkj C.C. CITY OF EDMONDS 4303 198`h Street SW, Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Offices Serving the Western United States 09621213 DFR -=—Krazan&ASSOCIATES GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION FORENSIC INVESTIGATION Date: Project No.: Project: Project Location: Krazan PM: May 10, 2021 096-21213 Singleton SFR 508 2' Ave N, Edmonds, WA JM/MR FIELD REPORT Report No.: 21213DFRO51021-NG Contractor: Property Owner Permit No.: BLD2021-0279 Inspector: Niccolo Guiao Jurisdiction: City of Edmonds Weather: Sunny Temp: 60's A Krazan geotechnical representative visited the project site today for a footing subgrade evaluation. Pro iect Description The house remodel project generally includes the demolition of an existing chimney and load bearing wall at the south central portion of the house. The demolished wall would be replaced by a new steel beam with the north end of the steel beam supported by a new interior isolated pad footing. The new interior isolated pad footing would be placed near the crawl space access. Geology Map We reviewed the "Geologic Map of the Edmonds East and Part of the Edmonds West Quadrangles, Washington" by James P. Minard (1983) during our project research. The geologic map indicates that the site vicinity is underlain by Quaternary Whidbey Formation (Qw). Pro iect Plans We have been provided with structural plans titled, "Singleton Remodel" by B2 Structural Engineers dated 04/21/21. The structural plans indicate an assumed allowable soil bearing pressure of 1,500 pounds per square foot (psf). Detail 2 on sheet S-1 show the new interior isolated pad footing sitting on the crawl space subgrade. Footing; Sukrade Evaluation Upon our arrival today, the demolition of the existing chimney and load bearing wall have started. It is our understanding that the bottom footing elevation of the new interior isolated pad footing would be the same as the crawl space subgrade elevation. To aid with our footing subgrade evaluation, we performed two (2) shallow hand tool explorations near the crawl space access and the footing of the demolished chimney. The crawl space subgrade consisted of brown silt. We evaluated the crawl space subgrade using a'/z-in diameter steel T-probe rod. The crawl space subgrade probed up to 4-in under moderate pressure, indicating stiff to very stiff conditions. We observed brownish gray silt to about 0.5-ft below the crawl space subgrade. The exposed subgrade soils probed up to 4-in under moderate pressure, indicating stiff to very stiff conditions. We interpreted the brown and brownish gray silt to native soils. See the attached site plan for the approximate locations of the new interior isolated pad footing and the hand tool explorations. This field report is for information purposes only. Superintendent/Representative: Technician: Niccolo Guiao 4303 —1981 Street SW • Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Offices Serving the Western United States KRAZAN & ASSOCIATES, INC. 09621213DFRO51021-NG Singleton SFR Page No. 2 Conclusion Based on our field observations, the subgrade area of the new interior isolated pad footing observed today is underlain by stiff to very stiff silt, interpreted as native soils. It is our opinion that the stiff to very stiff silt soils should adequately support the assumed allowable soil bearing pressure of 1,500 psf. We understand that the plan is to place the pad footing on the ground surface in the crawl space, and no excavation or foundation embedment is planned. We note that there is some potential for frost heave to affect the footing unless the bottom of footing is below the frost penetration line. Site Plan: I, a II n u n n li ,I u u u u r. r n II a I; !� U II II II !I II II III II ;I II — if :I IP 0 1± II N 11 I li EXISTING "ST 2X10 — I p i II II II II !I C AT 16 TO REMAIN I II 'I II II II II II if 11 II 0 I II I �a Approximate location of the hand tool ° !' explorations performed today. I A II n j _IF SPLICE_ EXISTING 9UT JOISTS 1 - ! WRH NEW 2X10 AT 16" TO it A II I INFILL EXISTING CHU.INEV ii II jY/ II fl I 0 II Y A WITH 10d T�1� �' TIER i1 11 II !I • II !I II II I U N II DN I II II A I I II I it 4 __ i it Y Y II N 1 N N srs'(NN)APAPLYWOOD FLOOR SHEATH.hO WITH IW NAILS AT 6' I N fl Il Y I Y EDGE NALING AND 10d AT 1i II I A n it q RELD NAILING i II A II A NEW WIOX30 STEEL n tl 11 II it A II BEAM (13-1) TO REPLACE EXISTING LOAD -BEARING WALLSELOW Y d II N II it U Y U U li I II II 11 N N II 11 II II II II fl II !! " ;� II II n M II 11 II II A II A Approximate location of the new II A Y N I� interior isolated pad footing. This field report is for information purposes only. Superintendent/Representative: Technician: Niccolo Guiao Krazan & Associates, Inc. Offices Serving The Western United States