FIR2022-0046_Fire_Alarm_Equipment_Specification_Sheets_5.3.2022_7.59.57_AM_2842473
EXISTING FACP (E)POTTER The Symbol of Protection Features • 100 addresses available on this analog addressable system • Additional system capacity achieved via multi -point SLC modules • 99 software zones • NFPA 72 Compliant Smoke Sensitivity Test Built -In • System Operates as Class A or Class B for SLC, P-Link and NACs • 5 Amp Power Supply, Expandable to 310 amps • 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188 • 2 Input/Output (1/0) Circuits for system flexibility rated at 1 Amp each • Strobe Synchronization and System Wide Sync for Gentex®, AMSECOO, Cooper Wheelock® and System Sensor® strobes • Dedicated Alarm, Supervisory and Trouble Relays • 4,000 Event History Buffer • Optional two line DACT with UD-2000 that can report General, Zone or Point Information • Built in IP Communicator AFC-100 Fire Alarm Control Panel PySEMB�FO #t O R •,y T�Q. • Ethernet Port for Programming and Network Connectivity O • E-Mail System Status, Reports and Event Information O NYC Fire Dept.'.. UL • Product includes 5 year warranty F M Certificate of Approval u 6256 LISTED APPROVED 7165-0328:0509 S735 Description The AFC-100 is an analog/addressable fire alarm system with a total system capacity of 100 addresses. Additional capacity on the system is achieved using multi -point SLC modules. The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC). The AFC-100 has a 5 Amp power supply with two Notification Appliance Circuits (NACS) and two Input/Output (I/O) circuits. The NACS are rated at 3 Amps each and the I/Os are rated at 1 Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Gentex, AMSECO, System Sensor and Cooper/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The NACS may be expanded using the PSN-1000 series intelligent power supplies. Each PSN-1000 adds another 10 Amps of power, 2 additional input circuits and the AFC-100 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN- 1000E has space to allow the installation of up to six loop expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections. Technical Specifications Dimensions 16"W x 17H x 3 %"D AC Mains 3.0 Amps @ 120 VAC 50/60 HZ 2.0 Amps @ 240 VAC 50/60 HZ Enclosure 16 gauge cold rolled steel with removable locked door with Lexan viewing window Standby Current-130 mA Alarm Current-200 mA • 5 Amps power for NACS, UO, and P-Link Battery • 3 Amps per NAC, regulated • 1 Amp per I/O circuit, regulated • Battery Charger range 8-55 Ah • Battery Charger voltage 27.3 VDC • P-Link maximum current of 1 Amp Temperature and 321 to 1201 (0°C to 49°C) with a maximum Humidity Range humidity of 93% non -condensing. • NFPA, 13, 15, 16, 17, 17A, 70, 72, and 750 • ANSI/UL 864 - Local (L), Remote Station (RS), Central Station (CS), Propriety (PPU), Auxiliary (AUX). Type of Service: Automatic (A), Manual (M),Water flow Standards (WF) Sprinkler Supervisory (SS) Type of Signaling: Digital Alarm Communicator (DAC), March Time (March), Non Coded (NC), Reverse Polarity (Rev Pol), Other Technologies (OT) • IBC (International Building Code) Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830134 - REV F • 2/22 PAGE 1 OF 5 (E)POTTER AFC-100 The Symbol of Protection Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 100 addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PAD200-PD Analog Photoelectric Smoke Detector is a smoke detector with a listed obscuration of 1.0 to 3.7%/foot. UL 268 7th Edition. PAD200-PHD Combination Analog Photoelectric Smoke/Heat Detector — a smoke detector with a listed obscuration of 1.0 to 3.5%/foot obscuration and a fixed temperature range of 135° to 1850 F heat detector. Smoke detection compliant with UL 268 7th Edition. PAD200-PCD Combination Photoelectric Smoke/Carbon Monoxide Detector. Smoke detection compliant with UL 268 7th Edition. Carbon Monoxide detection compliant with UL 2075. PAD200-PCHD Combination Photoelectric Smoke/Heat/Carbon Monoxide Detector. Smoke detection compliant with UL 268 7th Edition. Heat detection with a fixed temperature range of 135' to 185' F and is UL 268 and UL 521 7th Edition compliant. Carbon Monoxide detection compliant with UL 2075. PAD100-HD Analog Fixed Temperature (135' - 185°F) or Rate -of -Rise Heat Detector (software selectable). PAD200-DUCTR Addressable Duct Smoke Detector with Form C Relay rate at IOAmps @ 250/120VAC or 8 Amps at 30VDC. PAD200-DUCT Addressable Duct Smoke Detector. PAD 100-6B 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors. PAD100-413 4" round base that may be mounted to an electrical box and wired for connection to the above sensors. PAD100-I13 Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. PAD100-RB Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. PAD100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. PAD100-CD Addressable CO gas detector. PAD 100-DD Addressable photoelectric smoke detector for use in DUCT/DUCTR enclosure. PAD100-LFSB Addressable Low Frequency Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. The LFSB complies with the Low Frequency Signal Requirements (520 Hz). PAD100-SPKB Speaker base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1/8W to 4W. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830134 - REV F • 2/22 PAGE 2 OF 5 (E)POTTER The Symbol of Protection Modules AFC-100 Fire Alarm Control Panel Device PAD 100-MIM Description Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PAD 100-PSSA Single Action Addressable Pull Station. PAD 100-PSDA Dual Action Addressable Pull Station. PAD 100-SIM Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box. PAD 100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PAD 100-TRTI Two Relay Two Input module provides two form C relays that are individually controlled by the control panel. Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. Also provides two contact inputs. PAD 100-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PAD100-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system. PAD 100-IM Isolater Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. PAD100-RM Relay Module that provides one form C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. PAD 100-LED Module provides a single addressable LED that is controlled by the control panel. PAD 100-SM Speaker Module provides switching for two audio channels. PAD 100-LEDK Addressable LED and key switch that mounts in a single gang box. PAD 100-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised. For use with the PAD 100-DUCTR only. PAD100-0R0I One Relay One Input Module provides one form C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830134 - REV F • 2/22 PAGE 3 OF 5 (E)POTTER The Symbol of Protection AFC-100 Fire Alarm Control Panel SLC Features RA-6500R(F) — 4 x 40 LCD annunciator with a key pad in a locked The Potter protocol is a digital protocol with a proven design for metal enclosure. Flush mount version available. reliability and noise immunity. The system does not require special LED-16(F) — 16 LED annunciator with common indicators in a cable or conductors for connection of the Signaling Line Circuit locked metal enclosure. Flush mount version available. as long as the cable is compliant with NFPA 70 and NFPA 72. PSN-1000(E) — 10 amp, remote intelligent power supply with The system allows for Class A or Class B installations as well as 6 NACs, 2 Inputs and a P-Link repeater. This panel is listed in "T-Taps", with a max wiring distance of 10,000 Ft. conjunction with the AFC-100 as releasing circuits. CA-6075 — Class A convertor that converts the SLC, NACs and Sensor Features P-Link connection The sensors through the fire alarm control panel provide a real time status as to the condition of the system. The smoke detector sensitivity, heat detector temperature level and drift compensation are all programmable options. The system also allows for a day/night mode where the panel automatically adjusts the sensitivity depending on the time of day. To assist in the reduction of false alarms, the smoke detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the point that it can no longer maintain the programmed sensitivity. User Interface The fire alarm control panel has a 2 x 16 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LEDs: • AC Power - Green • Alarm - Red • Earth Fault - Amber • Supervisory - Amber • Silenced - Amber • Trouble - Amber • Pre -Release - Amber • Release - Red The common buttons include a Silence, Reset, Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. P-Link The AFC-100 has a proprietary communication protocol that communicates through a RS-485 connection to field devices. Up to 32 devices may be connected to a single P-Link connection. The P-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: SLCE-127 -Nohmi addressable loop expansion module for retrofit applications. UD-2000 — UL listed, Dual line telephone alarm communicator DRV 50 — LED driver expander, used to connect up to 50 LEDs in a graphic display FCB-1000 — Fire communication bridge, provides remote mounting of the Ethernet connection FIB-1000 — Fiber interface module, used to extend P-Link to multi - mode fiber (2 required) RLY-5 — Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC SPG-1000 — Serial parallel gateway, allows for the connection to a serial or parallel printer The FIB-1000, FCB-1000 and the SPG-1000 may be installed in the stacker bracket or ordered with the optional rack mount enclosure. MC-1000 Multi -Connect allows up to sixty-three AFC series panels to share a single reporting technology. IDC-6 — Initiating device circuit provides 6 programmable inputs AE-2 — Two card expansion cabinet AE-8 — Eight card expansion cabinet AE-14 — Fourteen card expansion cabinet Ethernet/I.P. Connection The AFC-100 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The IP communicator is listed to report to the UL listed Sur -Gard III IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830134 - REV F • 2/22 PAGE 4 OF 5 (E)POTTER The Symbol of Protection Dimensions a ® 00 0 0 FIgy49Ula Ordering Information AFC-100 Fire Alarm Control Panel ® O TOP • • DEPTH = 3.75 " 0 0 DOOR = 16.07" _ BACKBOX=15.77" DEPTH = 3.84" BOTTOM Model Description Stock No. AFC-100 Fire Alarm Control Panel 3992753 Replacement Board AFC-100 3992757 C) 0 RIGHT SIDE DWG #593-1 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830134 - REV F 2/22 PAGE 5 OF 5 ZV4 TELGUARD Telguard Online Telguard makes adopting cellular easy with a secure Internet portal. The straightforward web interface allows security dealers and central stations to quickly and efficiently access Telguard based services 24/7. This advanced tool has multi -level user authorization and provides total account management of UL Listed Telguard cellular alarm communicators. TG=7FS 3G CELLULAR ALARM COMMUNICATOR COMMERCIAL FIRE PRODUCT FEATURES II• Meets UL 864 requirements for sole, primary or backup path communications. IF Provides RMR protection with 3G technology, which operates on 2G, 3G and 4G networks. Supports listen -in, two-way voice verification over cellular. Minimizes false alarms by providing dual paths for self -tests. The Telguard TG-7FS is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2010 Edition of NFPA 72, the TG-7FS can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS, the monthly communications bill decreases. By being able to signal failures to the central station within five minutes of an outage, the TG-7FS can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS because of the new five minute supervision mode. The TG-7FS can also be installed as a backup path and upgraded to sole path at a later date. Telguard Cellular Service Telguard Cellular Service provides nationwide digital cellular network coverage for all Telguard units. Telguard's Communication Center is UL listed and provides seamless connectivity between the alarm panel, the Telguard family of products and the central station. Telguard Technical Support provides a single point of contact for both cellular service and Telguard product questions. Advanced Reliability • Features SMS backup to reduce false alarms, providing self -tests using SMS if GPRS fails. • Automatic self -tests with central station notification ensure the cellular system is operating. • Available relay output for tripping the alarm control panel when a trouble condition occurs. ZV4 TELGUARD TG=7FS 3G CELLULAR ALARM COMMUNICATOR (c0 Power (c11>) • Transmit power: 1.OW-2.OW ® — 3GCe,lular Telguard ■_. - '� (maximum allowable). Newo,k =omm��lallo c•�I•r • Power Consumption: Alarm Panel TG-7F5 cenna1S-1- Fire 60mA (Standby) Landi- 250mA (Transmission). oPtienau • Transformer: 12VAC, 800mA UL listed plug-in. Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for Radio Transceiver superior in -building penetration. • 3G cellular radio. • GSM 85OMHz: Class 4 (2 watts). Telguard products are easy to install, economical, and UL Listed. • GSM 190OMHz: Class 1 (1 watt). • UMTS WCDMA FDD 850/190OMHz. Accessories • Antenna: 9" dipole with 2dBi gain, • ACD 12, ACD 35, ACD 50, ACD 100: 12 ft of cable and universal mounting 12/35/50/100 feet of low loss, high performance cable. bracket. • HGD-0: High gain directional antenna. • FCC part 15, 22, 24 and 68 compliant. • EXD-0: External antenna. Physical Details • TG-7FS: 7.5" H x 11.5" W x 3.5" D. • Shipping Weight: 8lbs. • Operating Environment: 0°C to +50°C; up to 95% humidity (non -condensing). UL Listings Standard Features Commercial Fire Commercial Burglary Residential 864 • Control units & 365 Police Station 985 • Household fire • Full data reporting. accessories for fire connected burglar warning systems • Automatic self -test (5 min. & daily). alarm systems alarm units and 1023 • Household burglar systems alarm systems • Power supply with battery harness. 1610 • Central station • Locking, red metal enclosure. burglar alarm units • Two programmable supervisory For the most current product specifications and UL Listings visit www.Telguard.com. trip outputs. • Alarm format support for SIA2, Contact ID, pulse (3x1, 4x2), M] ����� modem Ile, & Illaz, DML P. 5*I , [0 - • Telephone line monitor built-j I SECURELECTRITY ASSOCIATION IC with Standard Line Security. .Ow �� " in, LISTED NFPA' /I �� Executive Strategic Partner INTERNATIONAL Gold Telguard, a Division of Telular Corporation • 2727 Paces Ferry Road SE • Suite 1-800 • Atlanta, GA 30339 • USA 800-229-2326, Option 5 • www.Telguard.com • Copyright ©2012 Telular Corporation • All Rights Reserved 012012Rev6