Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2022-0577_Manufacturer_Specifications_and_Installation_Instructions_5.5.2022_2.24.59_PM_2850530
BREAKING THE 20% EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behaviour. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.QTm. EXTREME WEATHER RATING High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY ro , Q.ANTUM DUO combines cutting edge cell separation I and innovative wiring with Q.ANTUM Technology. I APT test conditions according to I EC/TS 62804-1:2015, method B (-1500 V,168 h) 1 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: (10 Rooftop arrays residential buildings Engineered in Germany CELLS MECHANICAL SPECIFICATION Format 1879mm x 1045mm x 32mm (including frame) 18]9 mm 74„ Weight 22.0 kg lose mm71 3gs.s mm Front Cover 3.2 mm thermally pre -stressed glass with anti -reflection technology a.cmabmbeaolmsea.5mm� E] 4.-uMmaslots(DETAIL zUoomm ® � Illy A) j R.- B> Dmmsge holes 1 996mm 1045 mm 41.25" Back Cover Composite film Frame Black anodised aluminium Cell 6 x 22 monocrystalline Q.ANTUM solar half cells Junction box 53-101 mm x 32-60 mm x 15-18 mm Protection class IP67, with bypass diodes Cable 4mm2 Solar cable; (+) >1200 mm, (-) >:1200 mm Connector Staubli MC4, Hanwha Q CELLS HQC4; IP68 32mm DUAILA 1H 24.5mmI I8.5mm ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE +5W/ -OW) Power at MPP' PMPP [W] 385 390 395 400 405 Short Circuit Current' Isc [A] 11.04 11.07 11.10 11.14 11.17 E E Open Circuit Voltage' VDc IV] 45.19 45.23 45.27 45.30 45.34 5 Current at MPP IMPP [A] 10.59 10.65 10.71 10.77 10.83 2 Voltage at MPP VMPP IV] 36.36 36.62 36.88 37.13 37.39 Efficiency' q [%] >t19.6 >_19.9 >t20.1 >-20.4 >:20.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 Power at MPP PMPP [W] 288.8 292.6 296.3 300.1 303.8 E Short Circuit Current Isc [A] 8.90 8.92 8.95 8.97 9.00 E Open Circuit Voltage Voc IV] 42.62 42.65 42.69 42.72 42.76 .S 2 Current at MPP IMPP [A] 8.35 8.41 8.46 8.51 8.57 Voltage at MPP VMPP IV] 34.59 34.81 35.03 35.25 35.46 'Measurement tolerances PMPP±3%; Isc; Voc±5% at STC: 1000 W/m2, 25±2°C, AM 1.5 according to IEC 60904-3.2800 W/m2, NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE wo z _ °d At least 98 % of nominal power dur- aao w w 98 a�b Imo° Wertem� - ing first year. Thereafter max. 0.5 % o LLa .4 w degradation per year. At least u loo w ? of nominal power up to 10 years. At - w z least 86% of nominal power up to w I Q BO------------- �z > 25years. p ao--r-----r---------7------II 1 oa 14 All data within measurement toler- s ances. Full warranties in accordance so a with the warranty terms of the 200 400 Boo Boo loos o B4 Q CELLS sales organisation of your IRRADIANCE [W/m2] o a respective country. srnea�rea ro, ngamwPe ses ina man .i sa ba,2014) YEARS Typical module performance under low irradiance conditions in wih w°au<sP.W11zm4(s comparison to STC conditions (25°C,1000 W/m2). TEMPERATURE COEFFICIENTS Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of VDD [i [%/K] -0.27 Temperature Coefficient of PMcg y [%/K] -0.34 Nominal Module Operating Temperature NMOT [°C] 43±3 PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage Vsys IV] 1000 PV module classification Class II Maximum Reverse Current la [A] 20 Fire Rating based on ANSI /UL 61730 C/TYPE 2 Max. Design Load, Push/Pull [Pa] 3600/2660 Permitted Module Temperature-40°C-+85°C Max. Test Load, Push/Pull [Pa] 5400/4000 on Continuous Duty QUALIFICATIONS AND CERTIFICATES IEC 612016 IEC 61730 730:2016. This data sheet complies With DIN EN 50380. ruvsnsi�ls�a /` E to nnzzom Note: Installation instructions must be followed. Seethe installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwhe Q CELLS GmbH Sonnenallee 17-21, 06766 Bitterfeld-Wolfen, Germany I TEL+49 (0)3494 66 99-23444 1 FAX +49 (0)3494 66 99-23000 1 EMAIL salesQq-cells.com I WEB www.q-cells.com Engineered in Germany Cr CELLS SUNM*Mm69Fh:30 EZ Roof Mount Attachments EZ Roof Mount Attachments With L-Foot, Standoffs and Variants Pub. D10011-VO06 Copyright 2017 SUNM4019ph 0 Please read carefully before installing Patent # US8122648B EZ Roof Mount Attachments SunModo's EZ Roof Mount Attachments can be used to mount PV panels on pitch roofs. All installations shall be in accordance with NEC requirements in the USA. Table of Contents InstallerResponsibility: .......................................................................................................................... 3 Safety:................................................................................................................................................... 3 Specifications: ....................................................................................................................................... 3 LagPull -Out Capacities: ........................................................................................................................ 3 EZRoof Mount Series: ........................................................................................................................... 4 PrimaryMaterials: .................................................................................................................................. 5 Tools Required for Installation: .............................................................................................................. 8 TorqueValues: ...................................................................................................................................... 9 FlashingPlacement: ............................................................................................................................ 10 SealantApplication: ............................................................................................................................. 10 Installation Instructions: ....................................................................................................................... 11 EZ Roof Mount Kit K10068-XXX...................................................................................................... 11 EZ Roof Mounting Standoff Kit K10070-XXX.................................................................................... 12 EZ Roof Mount with C-Bracket Kit K12005-001................................................................................ 12 Optional Mounting Instructions: ............................................................................................................ 13 EZ Roof Mount Kit K10068-BK7....................................................................................................... 13 SunModo Corporation: Vancouver, Washington CE#�) www.SunModo.com Ph: 360-844-0048 Document Number D10011-V006 info@sunmodo.com 02017 — SunModo Corp. File 0248 2of14 A SUNM40 ,r EZ Roof Mount ,_ Attachments Installer Responsibility: Before ordering and installing materials, all system layout dimensions should be confirmed by field measurements. SunModo reserves the right to alter, without notice, any details, proposals or plans. Any inquiries that you may have concerning installation of the PV system should be directed to your SunModo Sales representative. Consult SunModo Sales for any information not contained in this manual. This manual is intended to be used as a guide when installing SunModo's EZ Roof Mount System on pitched roofs. It is the responsibility of the installer to ensure the safe installation of this product as outline herein. • Installer shall guarantee that screws and anchors have adequate pullout strength and shear capacities. • Installer shall adhere to the torque values specified in this Instruction Manual. • Installer shall use anti -seize compound, such as Permatex anti -seize, lubricant is recommended for all threaded parts. • Installer is responsible to install EZ Roof Mount System over a Fire Resistant roof covering rated for the application. • Installer is responsible to determine that the roof, its rafters, connections, and other architectural support components can sustain the array under all code level loading conditions. • Installer shall adhere to all relevant local or national building codes. This takes account of those that supplant this document's requirements. • Installer shall guarantee the safe placement of all electrical details of the PV array. • Installer shall comply with all applicable local, state and national building codes, including periodic re - inspection of the installation for loose components, loose fasteners and any corrosion, such that if found, the affected components are to be immediately replaced. Safety: Review relevant OSHA and other safety standards before following these instructions. The installation of solar PV systems is a dangerous procedure and should be supervised by trained and experienced personnel. It is not possible for SunModo to be aware of all the possible job site situations that could cause an unsafe condition to exist. The installer of the roof system is responsible for reading these instructions and determining the safest way to install the roof system. These instructions are provided only as a guide to show a knowledgeable, trained erector the correct part placement one to another. If following any of the installation steps would endanger a worker, the erector should stop work and decide upon a corrective action. Provide required safety railing, netting, or safety lines for crew members working on the roof. Specifications: EZ Roof Mount K10068 is certified for International Building Code and International Residential Codes (IRC) by IAPMO. Evaluation Report is 0248, structural test per EC002-2011 and rain test per UL 441-96. Lag Pull -Out Capacities: Sources: American Wood Council, NDS 2005, Table 11.2 A, 11.3.2 A capacitiesLag pull-out (withdrawal) lumber: Douglas Fir, Larch Gravity .50 per 1" thread depth 266 per 2-1/2" thread depth 665 Douglas Fir, South .46 235 588 Engelmann Spruce, Lodgepole Pine (MSR 1650 f & higher) .46 235 588 Hem, Fir .43 212 530 Hem, Fir (North) .46 235 588 Southern Pine .55 307 768 Spruce, Pine, Fir .42 205 513 Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) .50 266 665 Notes: 1) Actual test data in Southern Pine: Test Load at 0.250 inch deflection: 1,800 lbs. uplift (withdrawal); 240 lbs. lateral. Test Load at 0.125 inch deflection: 695 lbs. uplift (withdrawal); 130 lbs. lateral. 2) Thread must be embedded in a rafter or other structural roof member. 3) See NDS Table 11.5.1 C for required edge distances. 3of14 SUNM,,�A'W EZ Roof Mount Series: EZ Roof Mount Kit includes: • Flashing • L-Foot • Roof Shoe and Gasket • 4" Lag Bolt • AL Hex Cap • 3/8" Flange Nut and Bolt EZ Roof Mount Decking Kit: Flashing • L-Foot • Roof Shoe and Gasket • 4X 1/4 X 3" Decking Screw • AL Hex Cap • 3/8" Flange Nut and Bolt EZ Roof Mount Standoff Kit: Flashing • Roof Shoe and Gasket • 4" Lag Bolt oil ii • AL Hex Cap • 3/8" Flange Nut and Bolt • Standoff: 2" shown EZ Roof Mount C-Bracket Kit: • Flashing • Roof Shoe and Gasket • 4" Lag Bolt • AL Hex Cap • 3/8" Flange Nut and Bolt EZ Roof Mount Conduit Kit: • Flashing • L-Foot • Roof Shoe and Gasket • 4" Lag Bolt • AL Hex Cap • 3/8" Flange Nut and Bolt • Conduit Clamp 4of14 EZ Roof Mount Attachments K10068-XXX EZ Roof Mount with L-Foot (-001 as shown) K10068-B20 EZ Roof Mount with L-Foot (Black as shown) K10070-XXX EZ Roof Mount with Standoff (Standoff heights: 2", 3", 5" and 7") K12005-001 EZ Roof Mount Kit with C-Bracket K10205-001 EZ Roof Mount Kit, 1" Conduit K10205-002 EZ Roof Mount Kit, 3/4" Conduit EZ Roof Mount SUNM4019ph 0 Primary Materials: Aluminum Flashings are offered in two sizes: 10"X12.5" and 18"X18". A20052-XXX Available in clear, black and AL Flashing brown anodize. Aluminum L-Foot is offered in A20064-XXX clear, black and brown. AL L-Foot AL Hex Cap Available in clear and black Aluminum Shoe is provided with EPDM Sealing Washer installed Attachments A20066-001 and -BK1 AL Hex Cap A20065-001 AL Shoe C10006-001 Sealing Washer 5/16 Stainless Steel Lag Bolts are B15015-XXX available lengths: 3.5", 4", 4.5" 5/16 Stainless Steel Lag Bolt and 5" OMG XHD (Extra Heavy Duty) #15 Roofing Fastener Aluminum L-Foot available in clear and black. 5of14 B15040-001 (4 reqd per mount) OMG 1/4 X 3" Decking Screw XHD003B #15X3 K10066-XXX Standard L-Foot Kit K10096-XXX Tall L-Foot Kit (3/8" Flange Nut and Bolt included) EZ Roof Mount SUNM,,�A'w Attachments o Aluminum Standoff heights: 2", 3", A20049-XXX 5" and 7" Standoff (multiple lengths) (part of EZ Roof Kit K10070-XXX) Aluminum C-Bracket A22001-001 (part of EZ Roof Kit K12005-001) C-Bracket A20212-001 Conduit Clamp for 3/4" and 1" 1" Conduit Clamp diameter conduit A20213-001 e4o 3/4" Conduit Clamp Conduit Mount L-Foot A20064-004 Conduit Mount L-Foot Helio Rails: Features both 1/4" and 3/8" side slots, and 1 /4" top slot for clamping PV panels. Available in 84", 124", 164" and 206" lengths. Last 3 digits denote rail length. 4 stock sizes in clear and black. A20144-XXX (Clear) A20144-XXX-BK (Black) HR250 (Standard Rail) A20145-XXX (Clear) A20145-XXX-BK (Black) HR350 (Heavy Rail) A20146-XXX (Clear) A20146-XXX-BK (Black) HR500 (Super Rail) C10017-001 (Black) C10017-001-GR (Gray) Rail End Caps available for Helio Helio Standard Standard and Heavy rails (optional) C10021-001 (Black) C10021-001-GR (Gray) Helio Heavy A20284-001 A20284-BK1 (Black) HR250 (Helio Standard) Metal Rail End Caps available for Helio Standard and Heavy rails A20285-001 (optional) HR350 (Helio Heavy) A20263-001 HR500 (Helio Super) 6of14 EZ Roof Mount SUNM,..dAffW"hZ30 i HR150 (Open Rail): Features wire management channel and both 1/4" and 3/8" side slots, and 1/4" top slot for clamping PV panels. Available in 84", 124", 164" and 206" lengths. Last 3 digits denote rail length. 4 stock sizes in clear and black. Attachments A20242-XXX (Clear) A20242-XXX-BK (Black) HR150 (Open Rail) 1/4" Slot Open Rail Splice Kit with 4X 1/4-20 Bolts and Flange K10236-001 Nuts with integral grounding. May HR150 Splice Kit be repositioned until torqued For single -use only to final value. Rail End Cap available for A20250-001 (Clear) HR150 rails (optional) A20250-BK1 (Black) HR150 Rail End Cover HR150 Channel Clip: snaps into A20252-001 (Clear) the open rail to manage wire A20252-BK1 (Black) bundles where needed. HR150 Wire Cover Available in clear and black. The HR150 family of products are shown assembled above. Two HR150 Rails are spliced together with an HR150 Rail Splice. PV electrical wires are shown routed in the channels of the HR150 Rails, retained with two HR150 Channel Clips snapped into place. 7of3.4 EZ Roof Mount SUNM4019ph 0 Tools Required for Installation: Attachments Electric Drill or impact driver. Note that the use of an impact driver is strongly discouraged for all stainless nut and bolt hardware. Roofing Bar Drill Bit for lag bolts, pilot hole 7/32" diameter for 5/16" lag bolt 3/8" Socket Wrench Sockets for 3/8" drive sockets, 7/16", 1/2", 9/16" and 1-1/16" Torque Wrench 3/8" drive, 0 to 35 ft. lbs. 1PPPPPP'__1 J Anti -seize compound (Permatex 80071 or equivalent). 8of14 EZ Roof Mount SUNM,�MD Caulk gun and silicon sealant Chem Link M1 (or equivalent) for wood and composite roofs. Cheml-ink Dural -ink (or equivalent) for metal roofs. Tape measure Saws for cutting aluminum posts and rails as necessary Other items that can be useful: • Chalk or roofer's marker to layout roof. • Adaptor for 3/8" socket to drill chuck. • #3 Phillips bit ToUghTape 25' Attachments Torque Values: These values must be adhered to for mechanical strength. It is required that a torque wrench be used to measure the bolt torque during final assembly, and it is recommended that anti -seize compound, such as Permatex, be applied to the screw threads. Hardware Torque 1/4" Bolts and Hex Flange Nuts 7 7.5 ft. lbs. 1/4 X 3" Decking Fastener As Required 5/16 X 4" Lag Bolt 25 ft. lbs. 3/8" Bolts and Hex Flange Nuts 15 ft. lbs. 3/8" T-Bolts and Hex Flange Nuts 15 ft. lbs. Mid or End Clamp, 1/4-20 Female Standoff with 7/16" Hex Head Collar Nut 7.5 ft. lbs. Ground Lug: 1/4" Flange Nut with 7/16 hex drive head 7.5 ft. lbs. Ground Lug: 1/4" setscrew with1/8 Allen drive 4.2 ft. lbs. (50 in. lbs.) HEX Cap: 1-1/16" socket 15 ft. lbs. Note: We strongly recommend against the use of an impact wrench except for the installation of the Lag Bolts. 9of3.4 3/4"F-T-7: t I ' 2-1/4" NO INCORRECT Position Moisture and debris can accumulate causing early shingle degradation CORRECT Position No shingle cutting required 3rd shingle row ---- bd shingle row O Ist shingle row Acceptable Position If shingle cutting is required a 1/2" gap between the raised feature of the Flashing and the shingle is recommended Bead of sealant over the Flashing and under the shingle Bead of seala on each side under the Flashing EZ Roof Mount SUNM4019ph 0 Installation Instructions: EZ Roof Mount Kit K10068-XXX From the marked location, move down the roof 2-1/4" from the bottom of the shingle, and drill the pilot hole for the Lag Bolt with a 7/32" drill bit. For maximum strength, the hole should not be more than 3" in depth, and a drill stop may be used to insure this. 2. Clean sawdust, and fill hole with sealant, such as Chem - link M1 for wood and composite roofs, or ChemLink Dural -ink for metal roofs. Install AL Shoe to roof by using 5/16" Lag Bolt. Tighten to 25 ft. lbs. torque. 3. Make sure the Sealing Washer is positioned correctly on the threaded shank of the AL Shoe. Use roofer bar to lift roof shingle, slide the flashing under shingle, and insert the Flashing on threaded shank as shown. For additional waterproofing apply beads of sealant as shown. 4. Insert L-Foot to AL Shoe on top of Flashing. Place AL Hex Cap on Shoe, and lightly hand tighten Hex Cap. 5. Install AL Rail to L-Foot to the specific orientation. Then, tighten 3/8" Flange Nut to 15 ft-lbs. and Hex Cap to 15 ft- Ibs. torque. 11 of 14 Attachments EZ Roof Mount SUNM4019ph 0 Installation Instructions EZ Roof Mounting Standoff Kit K10070-XXX Mount the AL Shoe using steps 1-3 (shown above). A. Place AL Standoff on AL Shoe threads and tighten by hand, then by wrench. Use 15 ft.-Ibs. nominal torque. B. Using the 3/8" Flange Bolt (supplied with AL L-Foot) attach to the top of the Standoff. C. Install AL Rail to L-Foot to the specific orientation. Then, tighten 3/8" Flange Nut to 15 ft-Ibs. and Hex Cap to 15 ft-Ibs. torque. Installation Instructions EZ Roof Mount with C-Bracket Kit K12005-001 Mount the C-Bracket using steps 1-3 (shown above) D. Mount the C-Bracket instead of an L-Foot, using the Hex Nut. The C-Bracket can be used to mount a variety of rails and other rooftop equipment. 12 of 14 Attachments SUNM*MEN30 EZ Roof Mount Optional Mounting Instructions: EZ Roof Mount Kit K10068-B20 From the desired location, move down the roof 2-1/4" from the bottom of the shingle, and locate the EZ Roof Mount AL Shoe center. The AL Shoe will be used as a template to locate the 4 screws. 2. Place a bead of Chem -link M1 for wood and composite roofs along the length of the screw four (4) 1/4" X 3" self - drilling Decking Screws. Mount the AL Shoe to the roof through the shingles using the four Decking Screws. The screws will penetrate the roof sheathing and should protrude through the sheathing at least 1/2". Maximum pullout strength requires that the threads extend below the sheathing. 3. Make sure the Sealing Washer is positioned correctly on the threaded shank of the AL Shoe. Use roofer bar to lift roof shingle, slide the flashing under shingle, and insert the Flashing on threaded shank as shown. For additional waterproofing apply beads of sealant as shown. 4. Insert L-Foot to AL Shoe on top of Flashing. Place AL Hex Cap on Shoe, and lightly hand tighten Hex Cap. 5. Install AL Rail to L-Foot to the specific orientation. Then, tighten 3/8" Flange Nut to 15 ft-lbs. and Hex Cap to 15 ft- Ibs. torque. n. The self -drilling decking screw mount option is only suitable for roofs less than 5/12 pitch and should only be used with a direct L-Foot attachment. 13 of 14 Attachments SUNM*09'00 EZ Roof Mount Attachments See www.sunmodo.com for current warranty documents and information. SunModo Corporation Ph: 360-844-0048 14 of 14 SUNM%oArW":3� SunModo is focused on innovative racking and mounting solutions for professional installers in the fast-growing solar industry. Our solar mounting system features a patented grounding and bonding scheme that is designed into the mounting hardware for rails, clamps and splices. All self -grounding hardware meets NEC 690.43, ULz7o3 Grounding and Bonding and UL1703 Class -A Fire Rated for Type 1 and z PV modules tested by ETL. THE EZ ROOF MOUNT SYSTEM offers one of the most versatile, installer -friendly pitched roof mounting systems on the market. Our patented easy -to -use flagship EZ Roof Mount anchor 30OMW in installed capacity. With a full range of mounts and components, our pitched roof system can be configured in an endless variety of designs. In addition, SunModo offers a variety of mounts, from shingle to metal roof, to best fit your system needs and requirements. All system components have been UL2703 tested by ETL for electrical continuity, eliminating the need for additional grounding hardware. AN EZ Roof Mount Family e Helio aluminum i with corrosion anodized co Portrait Mid Clamp Landscape Mid Clamp Landscape End Clamp Self -grounding Splice Grounding Lug UL 467 tested by ETL SUNM4bAm69ffh:3\"--" THE EZ SUNBEAM SYSTEM is versatile and can be deployed as a ground mount or a roof mount solar panel racking system. When used for ground mounting steel supports can be integrated into this scalable system. When used roof mounting the system has been engineered to elevate above obstructions like HVAC, pipes and vents. a Heavy and Super Rail Post Cap Extrusions Pipe Clamp Angle Mount Solid base and aluminum post By spanning over obstacles, EZ SUNBEAM takes full advantage of roof space to maximize system size, increasing ROL Its aluminum construction reduces stress on the building structure while withstanding wind loads and salty air. A heavy duty beam allows longer spans, which reduces the number of posts. Since the system is a permanent part of the building, it eliminates any abrasions, moss build up and need of system removal for roof repair or re -roofing. TESTS, CERTIFICATIONS AND PATENTS: ETL CLASSIFIED E us /a TO Intertek 5001753 nec File 0248 SUNMra^. M U.S. Patent Numbers: 8,122.648 9,076,899 9,097,443 SunModo Corp 11905 E 5th Street, Suite A I Vancouver, WA 98661 1 360-844-0046 Document Number D10032-VO02 1 ©2015 — SunModo Corp. Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 0 MV IN m ;a PV power optimization at the module -level / Specifically designed to work with SolarEdge inverters / Up to 25% more energy / Superior efficiency (99.5%) / Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading / Flexible system design for maximum space utilization / Fast installation with a single bolt / Next generation maintenance with module - level monitoring / Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) / Module -level voltage shutdown for installer and firefighter safety solaredge.com solar =ee z Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 INPUT Rated Input DC Power() 320 340 370 400 405 485 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 60 1251ll 8312l Vdc MPPT Operating Range 8 - 48 8-60 8 - 80 8-60 12.5 - 105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 10.1 11.75 11 14 Adc Maximum DC Input Current 13.75 12.5 14.65 12.5 17.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0 , UV Resistant ROHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 129 x 153 x 27.5 / 5.1 x 6 x 1.1 129x153x33.5 /5.1x6x1.3 129x153x29.5 /5.1x6x1.16 129x159x49.5/5.1x6.3x1.9 129x162x59/ 5.1x6.4x2.3 mm /in Weight (including cables) 630 / 1.4 750 / 1.7 655 / 1.5 845 / 1.9 1064 / 2.3 gr / lb Input Connector p MC413' Single or dual MC4131w1 IvI Input Wire Length 0.16 / 0.52 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 0.9 / 2.95 1.2 / 3.9 m / ft Operating Temperature Range(') -40 - +85 / -40 - +185 °C / `F Protection Rating IP68 / NEMA6P Relative Humidity 0 -100 % (1) Rated power of the module at STC will not exceed the optimizer "Rated Input DC Power". Modules with up to +5% power tolerance are allowed 2) NEC 2017 requires max input voltage be not more than 80V (3) For other connector types please contact SolarEdge (4) For dual version for parallel connection of two modules use P485-4NMDMRM. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals. (5) For ambient temperature above +85°C / +185°F power de -rating is applied. Refer to Power Optimizers Temperature De -Rating Technical Note for more details. Minimum String Length P320, P340, P370, 8 10 18 (Power Optimizers) P400, P401 P405, P485, P505 6 8 14 Maximum String Length (Power Optimizers) 25 25 50(8) 5700 (6000 with Maximum Power per String SE7600-US - SE11400- 5250 60000) 1275000I W US) Parallel Strings of Different Lengths or Orientations Yes (6) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string-sizing-na.pdf (7) It is not allowed to mix P405/P485/P505 with P320/P340/P370/P400/P401 in one string (8) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (9) For 208V grid: it is allowed to install up to 6,500W per string when the maximum power difference between each string is 1,000W (10) For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W T ® SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. T �uS Ro H S All other trademarks mentioned herein are trademarks of their respective owners. Date: 04/2020/V02/ENG NAM. Subject to change without notice. CC Intertek