Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2022-0507+Site_Plan+5.5.2022_4.36.58_PM+2851138
DIRECTORY OF PLAN PAGES IIRON RIDGE FLASHFOOT2 MOUNTING DETAILS I PROJECT DETAILS PROPERTY OWNER CHRISTIEN MILLER PROPERTY ADDRESS 1002 WALNUT STREET EDMONDS, WA 98020 OWNER PHONE (206) 782-5869 APN 00434203500102 AHJ CITY OF EDMONDS ZONING RESIDENTIAL CONST. TYPE FLUSH ROOF -MOUNTED PHOTOVOLTAIC ARRAY UTILITY COMPANY SNOHOMISH COUNTY PUD OBSERVED CODES 2018 INTERNATIONAL BUILDING CODE 20181NTERNATIONAL RESIDENTIAL CODE 20181NTERNATIONAL MECHANICAL CODE 2018 INTERNATIONAL FUEL GAS CODE 2018 INTERNATIONAL EXISTING BUILDING CODE 20181CC PERFORMANCE CODE 2018 WASHINGTON STATE ENERGY CODE 2018 UNIFORM PLUMBING CODE 2018 INTERNATIONAL FIRE CODE 2020 NATIONAL ELECTRICAL CODE OSHA 29 CFR 1910.269 UNDERWRITERS LABORATORIES (UL) STANDARDS STRUCT.METHOD ASCE7-16 OWNER -BUILDER INFORMATION OWNER -BUILDER CHRISTIEN MILLER ADDRESS 1002 WALNUT STREET EDMONDS, WA 98020 PHONE (206) 782-5869 OWNER -BUILDER SIGNATURE PLAN DESIGNER INFORMATION COMPANY GEMINI SOLAR DESIGN, LLC. NAME SANJAY CHRISTOPHER MALLIPUDI ADDRESS 6020 ELK RIVER ROAD EUREKA, CA 95503 PHONE (609) 802-5743 PLAN DESIGNER SIGNATURE SYSTEM DETAILS DC RATING OF SYSTEM 13,30OW AC OUTPUT CURRENT 114SA MICROINVERTER (10) ENPHASE IQ7A-72-2-US MODULE (10) CANADIAN SOLAR CS3W-445MB-AG BRANCH CONFIGURATION 1 BRANCH OF 10 MICROINVERTERS INTERCONNECTION LOAD -SIDE SITE SPECIFICATIONS UTILITY SERVICE 1201240VAC, 1-0, 3W MAIN SERVICE PANEL (TOP -FED) 200A RATED BUSBAR 200A / 2P MAIN BREAKER 20A / 2P BACKFED SOLAR BREAKER ASHRAE EXTREME ANNUAL MEAN MINIMUM DENSITY DRY BULB TEMP. -70C ASHRAE 2% ANNUAL DRY DENSITY BULB TEMP. 29-C DESIGN WIND SPEED (ULTIMATE) 110 MPH GROUND SNOW LOAD 25 PSF WIND EXPOSURE CATEGORY C RISK CATEGORY II -�1ayton st r -myc1 s Maple 'Way Maple Nay Maple x MapEF S y r Yost Par Better Living Retreat Walnut 5t 1002 Walnut St, Edmonds, QUA 98020 spitice Sr?1�Ce SC Spruce PI 4 I1-urO LIB. Hemlock 5t 214rh P1 SW �15t - m � r PV_ move 00 R i PLOT PV-1 SCALE: NTS Adincgton w — r � 411� low rjISL'-I le } rerL M�nra� a,f*Mlount,BakeeS INlalnuat St Natl�l,a1 5 WA 98020 .r Kirkland RedmondOhl r % Be Wattlllevue Sarnmamish ` 'Mrerc6er 0)11& �`}� r� Alp' 111 Island �- � Issaquah Irewood North Peen` dw � en Renton „. vw4. ?' r 2 LOCALE PV-1 SCALE: NTS CONSTRUCTION NOTES CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS 1 PRIOR TO INITIATING CONSTRUCTION. CONTRACTOR SHALL REVIEW ALL MANUFACTURER 2 INSTALLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. ALL EQUIPMENT SHALL BE LISTED BY THE U.L. (OR 3 EQUAL) AND LISTED FOR ITS SPECIFIC APPLICATION. 4 ALL EQUIPMENT SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT IS INSTALLED. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE 5 WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. ACCESS TO ELECTRICAL COMPONENTS OVER 150 6 VOLTS TO GROUND SHALL BE RESTRICTED TO QUALIFIED PERSONNEL. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 7 VOLTS AND 90°C WET ENVIRONMENT, UNLESS OTHERWISE NOTED. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND 8 CONDUITS ARE NOT SPECIFIED, CONTRACTOR SHALL SIZE THEM ACCORDING TO APPLICABLE CODES. PV MODULES FRAMES SHALL BE BONDED TO RACKING 9 RAIL OR BARE COPPER G.E.C. PER THE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET. PV MODULES RACKING RAIL SHALL BE BONDED TO 10 BARE COPPER G.E.0 VIA WEEB LUG, ILSCO GBL-4DBT LAY -IN LUG, OR EQUIVALENT LISTED LUG. 11 GROUNDING ELECTRODE CONDUCTOR (G.E.C) SHALL BE CONTINUOUS AND/OR IRREVERSIBLY SPLICED ALL JUNCTION BOXES, COMBINER BOXES, AND 12 DISCONNECTS SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION. 13 WORKING SPACE AROUND ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC SECTION 110.26. SCOPE OF WORK DESCRIPTION THE PROPOSED SYSTEM IS A ROOF MOUNTED PHOTOVOLTAIC ARRAY. THE PHOTOVOLTAIC (PV) SYSTEM IS TO BE INSTALLED ON THE RESIDENTIAL ZONED PROPERTY IN THE CITY OF EDMONDS, WASHINGTON. THE ENERGY PRODUCED BY THE PV SYSTEM SHALL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ON -SITE ELECTRICAL EQUIPMENT VIA A LOAD SIDE CONNECTION. THIS PROJECT DOES NOT INCLUDE STORAGE BATTERIES. PHONE: 206 782-5869 CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. O w LLI GV U LLJ O Z Of O w M M CJ3 Q w� Z Q � Q Z w i�: O J J C4 O � w PROJECTINFO DRAWN BY: SCM DATE: 4/21 /2022 PV_ 1 16171 1 BRANCH OF 10 MICROINVERTERS (ENPHASE IQ7A-72-2-US) I I I 89' WALNUT STREET (N) PV ARRAY 180° AZIMUTH, 23° PITCH (10) CANADIAN SOLAR CS3W-445MB-AG I (10) ENPHASE IQ7A-72-2-US I N NEMA 3R J-BOX (LOC. UNDER MODULE) I I i E) UTILITY METER (LOC. ON INTERIOR) 1 42'-8" N SOLAR AC DISCONNECT ���� MODEL: SQUARE D DU221RB, ;------------------------ 30A RATED, 240VAC, NEMA 3R 96' ____ _______ -� i (LOC. ON EXTERIOR OF STRUCTURE, SHALL BE VISIBLE AND ACCESSIBLE) E 200A MAIN SERVICE PANEL (E) 200A / 2P MAIN BREAKER I 120 / 240VAC - 1 � - 3W - NEMA 3R (N) LOAD -SIDE INTERCONNECTION TO BE ACHIEVED VIA 20A / 2P BACKFED SOLAR CIRCUIT BREAKER (LOC. ON INTERIOR) I I I I I I 16\ 761 54'-8" I I I I I (E) SINGLE FAMILY DWELLING I 46'-7" I I I I I 36" I I _ 0,-2„ 108' 36" I I I 36" FIRE ACCESS PATHWAY I AS PER 2018 INTL. FIRE CODE (PURPLE HATCHED AREAS) I I I I I I I I I I I I E PROPERTY LINE SITE PLAN NOTES CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT 1 RESISTANT PER NEC 319.0(D). 2 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC 310.8(C). 3 ARRAYS SHALL BE INSTALLED IN A WAY THAT ENSURES THAT PV SOURCE CONDUCTORS SHALL NOT BE READILY ACCESSIBLE. A SITE PLAN PV-2 SCALE: 1" = 13'-0" CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. Y w 0 uj CD w z w LLI N U w o Z 00 Lu p CJ� E Q z w R�: O J J CV :�E o UJ w SITE PLAN PV-2 PM 1-10 PV SOLAR MODULE, TYP. (PM1) 445W + I — ENPHASE IQ7A-72-2-US MICROINVERTER (LOCATED UNDER PV MODULE) I I I 10 IN IBRANCH I I I I I- + I I I r---J I I I 1 NEMA 3R JUNCTION BOX (LOC. ON ROOF) TRANSITION FROM #12 ENPHASE TRUNK CABLE TO #10 THWN-2 CONDUCTORS TO BE I RAN INSIDE 0.50" DIA. EMT CONDUIT I I 2 I L------- SOLAR AC DISCONNECT MODEL: SQUARE D DU221 RB, DS 1 30A RATED, 240VAC, NEMA 3R (LOC, ON EXTERIOR OF STRUCTURE, 30A SHALL BE VISIBLE AND ACCESSIBLE) 3 TO UTILITY 0 0 J FKWHR ' CB1°1 ° 20A / l I \ i L(E) GROUNDING o 0 ELECTRODE, DRIVEN ROD, _ _ MIN. 6 FT DEPTH o 0 (E) 200A / 2P MAIN OCPD ►Y\ A MAIN SERVICE PANEL 120 / 240VAC,1-�, 3W 200A RATED BUSBAR 200A MAIN OCPD BREAKER REF. TYP. MODULE PM1-10 10 CANADIAN SOLAR CS3W-445MB-AG PV MODULE STC POWER PTC POWER ISC 445W 420.26W 11.59A IMP VOC VMP SERIES FUSE RATING PHONE: 206 782-5869 11.05A 48.5V 40.3V 25A CONFIDENTIAL: THE INFORMATION CONTAINED MICROINVERTER REF. TYP. MICROINVERTER GROUND AC VOLTAGE MAX MAX OUTPUT POWER MAX AC CURRENT MAX INPUT MAX INPUT CEC WEIGHTED OCPD SIZE (CONTINUOUS) CURRENT VOLTAGE EFFICIENCY 11-10 10 ENPHASE IQ7A-72-2-US INTEGRATED 240VAC 20A 349W 1.45A 15A 58VDC 97% SYSTEM SUMMARY BRANCH #1 INVERTERS PER BRANCH 10 ARRAY STC POWER 4,450W ARRAY PTC POWER 4,202W TOTAL MAX AC CURRENT 14.5A TOTAL MAX AC POWER 3,490W OCPD SCHEDULE REF. TYP. POLES CURRENT RATING MAX. VOLTAGE CBI (BACKFED SOLAR BREAKER) 1 2 20A 240VAC DISCONNECT SCHEDULE REF. TYP. POLES CURRENT RATING MAX. VOLTAGE DS1(SQUARED DU221RB) 1 2 30A 240VAC SCHEMATIC NOTES 0 THE FIRST AC CONNECTOR IN EACH MICROINVERTER BRANCH CIRCUIT IS SUITABLE AS A DISCONNECTING MEANS. OUTPUT OF SOLAR AC DISCONNECT IS CONNECTED TO UTILITY ON LOAD SIDE OF SERVICE 0 DISCONNECT. OUTPUT SHALL BE BACKFED THROUGH A 20A / 2P CIRCUIT BREAKER IN THE 200A MAIN SERVICE PANEL. THE SOLAR BACKFED BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE BUSBAR FROM THE MAIN BREAKER DISCONNECT. CONDUCTOR SCHEDULE WITH NEC ELECTRICAL CALCULATIONS TERMINAL BASE RATING CHECK AMPACITY CONDITIONS NO. OF TEMP. @ TEMP. of USE TEMP) CURRENT RATED CORR. FILL ADJ. CONT. MAX. (ASSUME 75°C FOR RATING @ 90°C TEMP. RATING ID TYP DESCRIPTION CONDUCTOR CONDUIT CARRYING FILL % OCPD EGC FACTOR @ THWN-2 & 60°C FOR CNDRS. AMPS 90°C TEMP. FACTOR CURRENT CURRENT NM-B, ROMEX) (AssuME so°c (ASSUME 90°C IN CNDT. RATING SHALL EXCEED FOR THWN-2 FORTHWN-2& 60°C FOR NM-B, 1.25X CONT. & 60°C FOR ROMEX) CURRENT NM-B, ROMEX) 12 AWG THWN-2 MICROINVERTER OUTPUT: COPPER FREEAIR 25A> 18.13A 40A 30.4A 1 1 MICROINVERTER TO N/A N/A 14.5A N/A 6 AWG BARE 0.76 (51 °C) 1.0 14.5A 18.13A JUNCTION BOX (ENPHASEIQ7A (DIRECT HOMERUN TO J-BOX COPPER PASS (INFREEAIR) (INFREEAIR) LOCATED UNDER PV MODULE) TRUNK CABLE) MICROINVERTER OUTPUT 2 10 AWG 35A> 18.13A 40A 30.4A 2 1 (TRANSITIONED): 10 AWG THWN-2 0.50"DIA. EMT 20.8 % 14.5A soA (Ds1) THWN-2 0.76 (51 °C) 1.0 14.5A 18.13A JUNCTION BOX TO COPPER (L1, L2) X 1 COPPER PASS (IN CONDUIT) (IN CONDUIT) AC DISCONNECT AC DISCONNECT OUTPUT: AC DISCONNECT TO 200A MAIN SERVICE PANEL 2 10 AWG 35A> 18.13A 40A 40A 3 1 (LOAD -SIDE POINT OF 10 AWG THWN-2 0.50"DIA. EMT 20.8% 14.5A 20A (CBI) THWN-2 1.0 (29°C) 1.0 14.5A 18.13A INTERCONNECTION VIA COPPER (L1, L2) X 1 COPPER PASS (IN CONDUIT) (IN CONDUIT) BACKFED DOUBLE POLE CIRCUIT BREAKER) ALL CONDUCTORS, OCPD SIZES AND TYPES SPECIFIED ACCORDING TO NEC ARTICLES 690.8(A)(1), NEC ARTICLE 240, AND NEC ARTICLE 690.7. IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. � O W L1J N Z orf 00 67 0 C/) Q co UJ JQ cl W O J O Lu W SINGLE -LINE DIAGRAMI DATE: 4/21/2022 PV-3 i I Mlls VA JUNCTION BOX RACEWAYS 10 JUNCTION BOX A WARNING A PHOTOVOLTAIC POWER SOURCE NEC 690.31(E)(3),(4) O JUNCTION BOX DO NOT ADISCONNECT A LINDERLOAD NEC 690.16(B) 3T RACEWAYS, CABLES PER 10 FT. A WARNING A PHOTOVOLTAIC POWER SOURCE NEC 690.31(E)(3),(4) MAIN SERVICE PANEL ® MAIN SERVICE PANEL ® WARNING A DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM NEC 690.56(B) © MAIN SERVICE PANEL A WARNING A INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE NEC 705.12(D)(7) ® BACKFED SOLAR CIRCUIT BREAKER (CB1) PHOTOVOLTAIC SYSTEM AC DISCONNECT OPERATING CURRENT 14.5AMPS OPERATING VOLTAGE 240VOLTS NEC 690.54 SIGNAGE REQUIREMENTS 1 ALL PLACARDS AND SIGNAGE REQUIRED BY THE 2020 NATIONAL ELECTRICAL CODE, AND ANY OTHER STATE CODES OR LOCAL ORDINANCES WILL BE INSTALLED AS REQUIRED. 2 RED BACKGROUND 3 WHITE LETTERING 4 MINIMUM 3/8" LETTER HEIGHT 5 ALL CAPITAL LETTERS 6 AERIAL OR SIMILAR FONT 7 IWEATHER RESISTANT MATERIAL, PER UL 969 O MAIN SERVICE PANEL A WARNING A ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.17.4 7O MAIN SERVICE PANEL SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF' POSITION TO sauac�ic SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY MAIN SERVICE PANEL 90 MAIN SERVICE PANEL A CAUTION A POWER TO THIS SERVICE IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN MAIN SERVICE PANEL (LOC. ON INTERIOR) AC DISCONNECT (LOC. ON EXTERIOR) N NEC 690.56(B) 1 PLACARDS PV-4 SCALE: NITS CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. w w CN z 00 w 0 G/ Q UJ � Q 0 w 3: O J J CV �E o � w PLACARDS PV-4 36" FIRE ACCESS PATHWAY 36" AS PER 2018 INTL. FIRE CODE (PURPLE HATCHED AREAS) I I I I I I I II I I IRON RIDGE FLASHFOOT2 I I I I I I I MOUNTING ATTACHMENT I I I I I @ 48" O.C. SPANS I I (STAGGERED FORMATION) I I l I II II II II II II CANADIAN SOLAR l I I CS3W-445MB-AG PV MODULE, TYP. I II II II II I II II II II IRON RIDGE XR-100 l SERIES RACKING RAIL 2" X 4" RAFTER II II II II II II @ 24" O.C. I II II N II II II II II II II II ROOF INFORMATION ROOF TYPE COMPOSITE SHINGLE PITCH 23' RAFTER SPACING 24" O.C. RAFTER DIMENSIONS 2" X 4" LAYOUT SPECIFICATIONS NUMBER OF MODULES 10 NUMBER OF MID -CLAMPS 18 NUMBER OF END -CLAMPS 4 NUMBER OF ATTACHMENTS 19 AREA 241 SQ. FT AZIMUTH 180° M. FA iwAp 000, I , FAR, 'PA A 10?44 PAN �pm P, do, II II II 2" II II II II 1 II II II II 8 II II II II I N II II II II II II I N II II II II II II I N II II II N II II I �n ii m FLq ii nn ii n = 23 II II III Ti I II II II I �^ II N II II II II II II II II N II II II N II II II II II II II N II II II N II II II II II II II II II II II II II II II II II II II II II II II II II N II II II I� �� 48" 24" 0 STRUCTURAL CALCULATIONS WIND EXPOSURE CATEGORY C RISK CATEGORY II DESIGN WIND SPEED (ULTIMATE) 110 MPH GROUND SNOW LOAD 25 PSF TOTAL WEIGHT OF ARRAY 721 LBS POINT LOAD (NO SNOW LOAD) 38.0 LBS POINT LOAD (25 PSF SNOW LOAD) 355.0 LBS DEAD LOAD (NO SNOW LOAD) 2.99 PSF DEAD LOAD (25 PSF SNOW LOAD) 27.99 PSF PV MODULES AND IRON RACKING SYSTEM HAVE A CLASS A FIRE RATING CLASSIFICATION. 24" ATTACHMENT PLAN NOTES 1 ROOF MEMBERS AND PENETRATIONS TO BE DETERMINED IN THE FIELD. 2 THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 3 PLEASE SEE SHEETS PV-6A, PV-6B, AND PV-6C FOR DETAILS REGARDING THE MOUNTING ATTACHMENT TO BE USED, THE FLASHING TO BE USED, AS WELL AS THE RELEVANT INSTALLATION INSTRUCTIONS. PLEASE SEE SHEET PV-11 FOR A STRUCTURAL CERTIFICATION LETTER FOR THE IRON RIDGE FLUSH MOUNT 4 SYSTEM. LETTER IS STAMPED BYA STATE OF WASHINGTON REGISTERED PROFESSIONAL ENGINEER (PE). 1 ATTACHMENT PLAN PV-5 SCALE: 1" = 4'-8" CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. Ln Ln I � II II 7' Lu ~ II II C I II Lu II � 0 36" I w Z LU w oN Z UJ 00 rn 0 1 Lu cn 0f Q Z Lu O ATTACHMENT PLAN DATE: 4/21 /2022 PV-5 idbol'*rA OWNER -BUILDER NAME: CHRISTIEN MILLER PHONE: 206 782-5869 W CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND VQ SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM IRONRIDGE RAIL 1 REPRESENTED IN THIS PLAN. w IRONRIDGE FLASHFOOT2 a o 3 s Y o C O s H aM 7.4 i W w o C VARIES N / X J _ Y 7.4 — ` L0 W R � LJJ L1J NO w U LLJ O Lu p w N z l C� SIDE VIEW, FLASHFOOT2 MOUNT, PORTRAIT MODULE p o Q Scale: l"=1' 0" 0 o C� W 0 o o Z o 2 LL1 3: zO w J CN � o � O '0 Z 2 U N � O L1J f W w ~ W a O 00 w v p a > LJJ IRONRIDGE UNIVERSAL rc Z FASTENING OBJECT w F PV MODULE FRAME w D 7.0 PV MODULE FRAME 7.0 3„ IRONRIDGE UNIVERSAL W ' 8 — FASTENING OBJECT IRONRIDGE RAIL O N O w r C a v F a p F 0 7.0 w w w a w O x o p a p p o 3 y w g B DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT 7.0 Scale: 6"=1'-O" Scale: 6"=1'-O" A PLAN VIEW FLASHFOOT2 MOUNT PORTRAIT MODULE SOS G \off Scale: 1"=1'-0" c0� IRONRIDGE STOPPER SLEEVE IRONRIDGE RAIL IRONRIDGE UNIVERSAL IRONRIDGE FLASHFOOT2 IRONRIDGE IRONRPPER IDGE UNIVERSAL NIVERSEEVE STENING OBJECT PV MODULE FRAME PV MODULE FASTENING OBJECT G J IRONRIDGE UNIVERSAL IRONRIDGE UNIVERSAL PV MODULE FRAME 7.0 /`7610) IRONRIDGE RAIL 7.4 FASTENING OBJECT �-� FASTENING OBJECT IRONRIDGE STOPPER IRONRIDGE RAIL SLOPED ROOF SLEEVE PVSYSTEM MOUNTING DETAIL DETAILS: FLASHFOOT2 L _ L (UFO) 0.4xL MAX. FRONT VIEW, FLASHFOOT2 MOUNT, PORTRAIT MODULE iF DETAIL, END CLAMP (UFO) PLAN G DETAIL, END CLAMP (UFO) FRONT Scale: 6"=1'-O" Scale: 6"=1'-O" ss°E�° 3.1 SR PROJECT N0; GSD 20220421 175617 Scale: 1"=1'-0" IR 7'0 DRAWN BY: SCM g 24x36DATE:4/21/2022 IRON RIDGE FLASHFOOT2 MOUNTING DETAILS PV-6AV-6 SCALE: NTS OWNER -BUILDER NAME: CHRISTIEN MILLER PHONE: 206 782-5869 W CONFIDENTIAL: THE INFORMATION CONTAINED PV MODULE, BY OTHERS PV MODULE, IN THIS DRAWING SET IS CONFIDENTIAL AND BY OTHERS SHALL NOT BE DISCLOSED IN FULL OR IN PART IRONRIDGE IRONRIDGE RAIL N TO ANYONE EXCEPT THOSE INVOLVED IN THE RAIL TOP -FACING SLOT a 0 DESIGN AND INSTALLATION OF THE PV SYSTEM TOP -FACING SLOT (E) ROOF (E) ROOF TOP -FACING SLOT REPRESENTED IN THIS PLAN. MEMBRANE MEMBRANE UNDERMOUNTING SLOT O o INTERNAL SPLICE INTERNAL SPLICE INTERNAL SPLICE Z 3 z a o O IRONRIDGE IRONRIDGE SIDE -FACING SLOT SIDE -FACING SLOT w > R FLASHFOOT2 FLASHFOOT2 SIDE -FACING SLOT a N (E) BUILDING (E) BUILDING S w N o " STRUCTURE STRUCTURE o v FLASHFOOT2 DETAIL FLASHFOOT2 DETAIL DETAIL, SPLICE, XR1000 DETAIL, SPLICE, XR100 DETAIL, SPLICE, XR10 IN ` Lin U Scale: 3"=1'-O" U Scale: 3"=1'-0" 1' 0"=1'-0" 1' 0"=1'-0" O M SELF -DRILLING SCR W W U w o Z I� CD 1.2 Z Lu � rn cw9 0 0 0 Q IRONRIDGE RAIL 0 w Z (/) — w W J M y J 3: Q 0 J N C) w a IRONRIDGE INTERNAL SPLICE C O Lu Z W W Y C Lu ~ U OO V DETAIL, SPLICE CONNECTION, XR1000 (L a U) IRONRIDGE FLASHFOOT2, SIDE VIEW 6"=1'-O" P W U Z GROUNDING STRAP, w INSTALLED AS NEEDED 9. 0 SELF -DRILLING SCREW IRONRIDGE FLASHFOOT2 J w U to b:J a a o IRONRIDGE RAIL w¢ W 3 Cw K U w w w N; 0 0 0 z N w IRONRIDGE INTERNAL SPLICE 1" MIN. DETAIL, EXPANSION JOINT CONNECTION, XR1000 01F R "5 GO „r 16 SLOPED MOUNTING DETAIL PV SYSTEM SYSTEM L2i'j DETAILS: FLASHFOOT2 R IRONRIDGE FLASHFOOT2 FRONT VIEW IRONRIDGE FLASHFOOT2, PLAN VIEW & PROJECT N0: GSD-20220421-175617 " 3.1 SR DEC 2018 DRAWN BY: SCM IR 7.4 DATE: 4/21/2022 24X36 IRON RIDGE FLASHFOOT2 MOUNTING DETAILS PV-6B V-66 SCALE: NTS IRONRIDGE FlashFoot2 (3.56) (1.02 (3.67) i3 2 4 THIS EDGE TOWARDS ROOF RIDGE 1 (12.00) i I ( 3.00 4.50 9.00 NO. DESCRIPTION 1 ASSY, FLASHING, MILL OR BLACK 2 ASSY, CAP, MILL OR BLACK KIT, FLASHFOOT2 3 BOLT LAG 5/16 X 4.75" A I DO NOT SCALE DRAWING 4 WASHER, EPDM BACKED SCALE :1:4 1 WEIGHT: 0.881b SHEET I G17 © 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. FM-FF2-MAN REV 1.20 Installation Tools Required: tape measure, chalk line, stud finder, roofing bar, caulking gun, driver with 1/4" bit and 7/16" hex socket. 1JEMSFmom IM11,15al UUMMME Locate rafters and snap vertical and horizontal lines to mark flashing locations. Drill 1/4" pilot holes, then fill with roofing manufacturer's approved sealant. Line up pilot hole with flashing hole and insert lag bolt with bonded washer through flashing. Tighten lag bolt until fully seated. Attach rails to either side of the open slot using bonding hardware. Level rail at desired height, then torque to 250 in-lbs (21 ft-lbs). 3 course 2nd course Slide flashing, between 1st and 2nd course, so the top is at least 3/4" above the edge of the 3rd course and the bottom is above the edge of the 1 st course. Iiiiiiia Place Cap onto flashing in desired orientation for E/W or N/S rails and rotate 180 degrees. FlashFoot 2 is now installed and ready for IronRidge XR Rails. Structural Certification Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7. Water Seal Ratings Water Sealing Tested to UL 441 Section 27 "Rain Test" and TAS 100-95 "Wind Driven Rain Test" by Intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. Tested and evaluated without sealant. Any roofing manufacturer approved sealant is allowed. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See IronRidge Flush Mount Installation Manual for full ratings. © 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. FM-FF2-MAN REV 1.20 1 IRON RIDGE FLASHFOOT2 INSTALLATION V-6C SCALE: NTS CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. W C/) C/) M Uj CD W Z � o W L1J N Z� 00 rn 0 U) Q LU Cn Q C) W 3: O J CV �i � O LU W INSTALLATION 5*13VA PV-6C IRONRIDGE Built for solar's toughest roofF Datasheet Flush Mount System IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested All components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. ® UL 2703 Listed System Entire system and components meet newest effective UL 2703 standard. PE Certified Pre -stamped engineering letters available in most states. Design Assistant Online software makes it simple to create, share, and price projects. 25-Year Warranty Products guaranteed to be free of impairing defects. AA XR Rails O XR10 Rail i A low -profile mounting ra I for regions with light snow. • 6' spanning capability • Moderate load capabili y • Clear and black finish Clamps & Grounding O UFOs 1� A e Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear and black finish Attachments O FlashFoot2 i Flash and mount XR Rails with superior waterproofing. • Twist -on Cap eases install • Wind -driven rain tested • Mill and black finish Resources XR100 Rail The ultimate residential solar mounting rail. • 8'spanning capability • Heavy load capability • Clear and black finish Stopper Sleeves Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • Sized to match modules • Clear and black finish Conduit Mount Flash and mount conduit, strut, or junction boxes. • Twist -on Cap eases install • Wind -driven rain tested • Secures 3/a" or 1" conduit /:i[11Z1Z11l:F11 A heavyweight mounting rail for commercial projects. • 12'spanning capability • Extreme load capability • Clear anodized finish CAMO Bond modules to rails while staying completely hidden. • Universal end -cam clamp • Tool -less installation • Fully assembled Slotted L-Feet Drop -in design for rapid rail attachment. • Secure rail connections • Slot for vertical adjusting • Clear and black finish Datasheet Bonded Splices All rails use internal splices for seamless connections. • Self -drilling screws • Varying versions for rails • Forms secure bonding Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction Bonding Hardware l Bond and attach XR Rails to roof attachments. • T & Square Bolt options • Nut uses 7/16" socket • Assembled and lubricated --..- -- Design Assistantified Training - - Go from rough layout to fully CO)a''Earn free continuing education credits, NABCEP _ engineered system. For free. while learning more about our systems. — Go to IronRidge.com/design � Go to IronRidge.com/training wwwr 1 FLUSH MOUNT RACKING DATASHEET PV-7 SCALE: NTS CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. Y W C/) C/) M UJ CD W Z I— O W UJ N Z00 W rn 0 Q UJ CO of JQ W 3: O o LU W RACKING DATASHEET PV-7 idt171t1 oouumlrr„°,,.. 'NEW= �O"o...... BiHiKu SUPER HIGH POWER BIFACIAL MONO PERC MODULE 420 W - 445 W UP TO 30% MORE POWER FROM THE BACK SIDE CS3W-420 1 425 1 430 1 435 1 440 1 445M B-AG MORE POWER EXTRA Up to 30% more power from the POWER backside 4 24 % higher front side power than conventional modules Low NMOT: 41 ± 3 °C 41°C Low temperature coefficient (Pmax): -0.35 % / °C + Better shading tolerance MORE RELIABLE Lower internal current, lower hot spot temperature Minimizes micro -crack impacts * * * Heavy snow load up to 5400 Pa, 0 wind load up to 3600 Pa * * For detail information, please refer to Installation Manual. �� CanadianSolar 111110 loss wool an FRONT BACK i\ years - linear power output warranty* 30 3 enhanced product warranty on materials I yl2 ? and workmanship* *According to the applicable Canadian Solar Limited Warranty Statement. MANAGEMENT SYSTEM CERTIFICATES* ISO 9001:2015 / Quality management system ISO 14001:2015 / Standards for environmental management system OHSAS 18001:2007 / International standards for occupational health & safety PRODUCT CERTIFICATES* IEC 61215 / IEC 61730: VDE / CE / MCS / INMETRO UL 1703: CSA/IEC 61701 ED2: VDE/IEC 62716: VDE/IEC 60068-2-68: SGS Take-a-way CCDVE c* -a ��� ME * As there are different certification requirements in different markets, please contact your local Canadian Solar sales representative for the specific certificates applicable to the products in the region in which the products are to be used. CANADIAN SOLAR INC. is committed to providing high quality solar products, solar system solutions and services to cus- tomers around the world. No. 1 module supplier for quality and performance/price ratio in IHS Module Customer Insight Survey. As a leading PV project developer and manufacturer of solar modules with over 40 GW deployed around the world since 2001. CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario N1 K 1 E6, Canada, www.canadiansolar.com, support@canadiansolar.com ENGINEERING DRAWING (mm) Rear View CS3W-435MB-AG / I-V CURVES Frame Cross Section A A 12 12 A -A 11 11 10 10 23 9 9 8 8 � m 6 6 6 5 5 4 4 3 3 2 z Mounting Hole 1 1 o vo v 5 10 15 20 25 30 35 40 45 50 5 10 15 20 25 30 35 40 45 50 ■ 1000 w1W 5-C ■ ■ 800 W/W 25-C ■ 600 W/W 45-C 0 400 W/m' 65-C 200 W1W ELECTRICAL DATA I STC* ELECTRICAL DATA I NMOT* Nominal Opt. Opt. Open Short Nominal Opt. Opt. Open Short Max. Power Operating0perating Voltage Current Circuit Circuit Voltage Current Module Efficiency Max. Operating0perating Circuit Circuit Power Voltage Current Voltage Current (Pmax) (Vmp) (Imp) (Voc) (ISO (Pmax) (Vmp) (Imp) (Voc) (Isc) CS3W-420MB-AG 420 W 39.9 V 10.53 A 47.9 V 11.27 A 18.8% CS3W-420MB-AG 315 W 37.3 V 8.42 A 45.2 V 9.09 A 5% 441 W 39.9 V 11.06 A 47.9 V 11.83 A 19.7% CS3W-425MB-AG 318 W 37.5 V 8.48 A 45.4 V 9.13 A Bifacial 10% 462 W 39.9 V 11.58 A 47.9 V 12.40 A 20.7% Gain** 20% 504 W 39.9 V 12.64 A 47.9 V 13.52 A 22.6% CS3W-430MB-AG 322 W 37.7 V 8.54 A 45.6 V 9.17 A 30% 546 W 39.9 V 13.69 A 47.9 V 14.65 A 24.4% CS3W-435MB-AG 326 W 37.9 V 8.59 A 45.8 V 9.21 A CS3W-425MB-AG 425W 40.1 V 10.60A 48.1 V 11.32A 19.0% C53W-440MB-AG 329 W 38.1 V 8.65 A 46 V 9.26 A 5% 446 W 40.1 V 11.13 A 48.1 V 11.89 A 20.0% Bifacial 10% 468 W 40.1 V 11.66 A 48.1 V 12.45 A 20.9% CS3W-445MB-AG 333 W 38.3 V 8.71 A 46.1 V 9.31 A Gain** 20% 510 W 40.1 V 12.72 A 48.1 V 13.58 A 22.8% * Under Nominal Module Operating Temperature (NMOT), irradiance of 800 W/m' 30% 553 W 40.1 V 13.78 A 48.1 V 14.72 A 24.8% spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s. CS3W-430MB-AG 430 W 40.3 V 10.68 A 48.3 V 11.37 A 19.2% 5% 452 W 40.3 V _ 11.21 A 48.3 V 11.94 A 20.2% Bifacial 10% 473 W 40.3 V 11.75 A 48.3 V 12.51 A 21.2%_ Gain** 20% 516 W 40.3 V 12.82 A 48.3 V 13.64 A 23.1 % MECHANICAL DATA 30% 559 W 40.3 V 13.88 A 48.3 V 14.78 A 25.0% Specification Data CS3W-435MB-AG 435 W 40.5 V 10.75 A 48.5 V 11.42 A 19.5% Cell Type Mono -crystalline 5% 457 W 40.5 V 11.29 A 48.5 V 11.99 A 20.5% Cell Arrangement 144 [2X (12 X6) ] Bifacial 10% 479 W 40.5 V 11.83 A 48.5 V 12.56 A 21.4% Dimensions 2132 x 1048 x 30 mm (83.9 x 41.3 x 1.2 in) Gain** 20% 522 W 40.5 V 12.90 A 48.5 V 13.70 A 23.4% 30% 566 W 40.5 V 13.98 A 48.5 V 14.85 A 25.3% Weight 28.4 kg (62.6 Ibs) CS3W-440MB-AG 440 W 40.7 V 10.82 A 48.7 V 11.48 A 19.7% Front / Back Glass 2.0 mm heat strengthened glass 5% 462 W 40.7 V 11.36 A 48.7 V 12.05 A 20.7% Frame Anodized aluminium alloy Bifacial 10% 484 W 40.7 V 11.90 A 48.7 V 12.63 A 21.7% j-Box IP68, 3 diodes Gain** 20% 528 W 40.7 V 12.98 A 48.7 V 13.78 A 23.6% Cable 4.0 mm2 (IEC), 12 AWG (UL) CS3W-445MB-AG 445 W 40.9 V 10.89 A 48.9 V 11.54 A 19.9% Length In Portrait: 400 mm (15.7 in) (+) / 280 mm Cable Len clu- 9 ( (11.0 in) 0; landscape: 1400 mm (55.1 in); 5% 467 W 40.9 V 11.43 A 48.9 V 12.12 A 20.9% ding Connector) leap -frog connection: 1850 mm (72.8 Dr Bifacial 10% 490 W 40.9 V 11.98 A 48.9 V 12.69 A 21.9% Connector T4 series or H4 UTX or MC4-EV02 Gain** 20% 534 W 40.9 V 13.07 A 48.9 V 13.85 A 23.9% Per Pallet 33 pieces 30% 579 W 40.9 V 14.16 A 48.9 V 15.00 A 25.9% Per Container (40' HQ) 660 pieces or 561 pieces (only for US) temperature of 25°C * For detailed information, please contactyour local Canadian Solar sales and techni- ** Bifacial Gain: The additional gain from the backside compared to the power of the front side cal representatives. at the standard test condition. It depends on mounting (structure, height, tilt angle etc.) and albedo of the ground. ELECTRICAL DATA TEMPERATURE CHARACTERISTICS Operating Temperature -40°C-+851C Max. System Voltage 1500 V (IEC/UL) or 1000 V (IEC/UL) Specification Data Module Fire Performance TYPE 3 (UL 1703) Temperature Coefficient Pmax -0.35 %/ °C p (Pmax) or CLASS C (IEC61730) Temperature Coefficient (Voc) 0.27 %/ °C Max. Series Fuse Rating 25 A Application Classification Class A Temperature Coefficient (Isc) 0.05 %/ °C Power Tolerance 0 -+ 10 W Nominal Module Operating Temperature 41 ± 3°C Power Bifacialitv* 70 % * Power Bifaciality= Pmax.. / Pmax. , both Pmax, and Pmax., are tested under STC, Bifacia- lity Tolerance: ± 5 % PARTNER SECTION *The specifications and key features contained in this datasheet may deviate slightly from our .......................".................................................."'........... actual products due to the on -going innovation and product enhancement. Canadian Solar Inc. reserves the right to make necessary adjustment to the information described herein at any time without further notice. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our PV modules. ....................................................................................................................................................................... .............................. . ............... ................ CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario N1 K 1 E6, Canada, www.canadiansolar.com, support@canadiansolar.com May 2020. All rights reserved, PV Module Product Datasheet V5.59_EN PV MODULE DATASHEET PV 8 SCALE: NTS CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. W C/) C/) M UJ UJ z W W No C-) W o z Of CC) UJ W W ¢ � J 3Z 0 O LU W MODULE DATASHEET DATE: PV-8 Data Sheet Enphase Microinverters Region: AMERICAS Enphase IIQ 7A Microinvertpr m To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7A Micro'" dramatically simplifies the installation process while achieving the highest system efficiency for systems with 60-cell and 72-cell modules. Part of the Enphase IQ System, the IQ 7A Micro integrates with the Enphase IQ Envoy'", Enphase IQ Battery'", and the Enphase Enlighten- monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. High Power • Peak output power 366 VA @ 240 VAC and 295 VA @ 208 VAC Easy to Install Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014, 2017 & 2020) Efficient and Reliable Optimized for high powered 60-cell and 72-cell modules Highest CEC efficiency of 97% More than a million hours of testing Class II double -insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride - through requirements Envoy and Internet connection required Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) O=i ENPHASE Enphase IQ 7A Microinverter INPUT (DC) IQ7A-72-2-US Commonly used module pairings' 295 W-460 W + Module compatibility 60-cell, 66-cell and 72-cell PV modules Maximum input DC voltage 58 V Power point tracking voltage range 18 V-58 V Min/Max start voltage 33 V / 58 V Max DC short circuit current (module Isc)' 15 A Overvoltage class DC port II DC port backfeed current 0 A CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT (AC) @ 240 VAC @ 208 VAC Peak output power 366 VA 295 VA Maximum continuous output power 349 VA 290 VA Nominal (L-L) voltage/range4 240 V / 211-264 V 208 V / 183-229 V Maximum continuous output current 1.45 A (240 VAC) 1.39 A (208 VAC) Nominal frequency 60 Hz LO Extended frequency range 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A (L-L) branch circuits 11 (240 VAC) 11 (208 VAC) Overvoltage class AC port III UJ AC port backfeed current 18 mA I — Power factor setting 1.0 Power factor (adjustable) 0.85 leading ... 0.85 lagging >_ Q EFFICIENCY @240 VAC @208 VAC CEC weighted efficiency 97.0 % 96.5% W MECHANICAL Ambient temperature range -400C to +60°C Relative humidity range 4% to 100% (condensing) Q Connector type: DC (IQ7A-72-2-US) MC4 Dimensions (HxWxD) 212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 Ibs) Cooling Natural convection - No fans W Approved for wet locations Yes Z Pollution degree PD3 Enclosure Environmental category / UV exposure rating Class II double -insulated, corrosion resistant polymeric enclosure NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020, section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-com atp ibility. 2. CEC peak power tracking voltage range is 38 V to 43 V. 3. Maximum continuous input DC current is 10.2A. 4. Voltage range can be extended beyond nominal if required by the utility. 5. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com @ 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7A, Enphase IQ Battery, Enphase Enlighten, Enphase IQ E N PHASE Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 11-04-2021 MICROINVERTER DATASHEET PV 9 SCALE: NTS W W No U Lu o z 110:� CO W I— LU U) � Q � W 3: O O I� W NVERTER DATASHEET DATE: PV-9 8431 Murphy Drive Middleton, WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com Test Verification of Conformity In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. licant Name & Address: Product Description: IronRidge, Inc. 1495 Zephyr Ave. Hayward, CA 94544 USA Flush Mount System with XR Rails. Ratings & Principle Fire Class Resistance Rating: Characteristics: -Flush Mount (Symmetrical). Class A Fire Rated for Low Slope applications when using Type 1, 2 and 3, listed photovoltaic modules. Class A Fire Rated for Steep Slope applications with Type1, 2 and 3, listed photovoltaic modules. Tested with a 5" gap (distance between the bottom the module frame and the roof covering), per the standard this system can be installed at any gap allowed by the manufacturers installation instructions. No perimeter guarding is required. This rating is applicable with any IronRidge or 3'rd party roof anchor. Models: Brand Name: IronRidge Flush Mount with XR Rails IronRidge Flush Mount Relevant Standards: UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat -Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18, 2014, (Section 31.2) Standard for Safety for Flat -Plate Photovoltaic Modules and Panels. Verification Issuing Office: Intertek Testing Services NA, Inc. 8431 Murphy Drive Middleton, WI 53562 Date of Tests: 08/27/2014 to 03/17/2015 Test Report Number(s): 101769343MID-001r1, 101769343MID-001a, 101915978MID-001 & 101999492MID-001ar1-cr1 This verification is part of the full imply product certification. Completed by: Chris Zimbrich Reviewed by: Chad Naggs Title: Technician II, Fire Resistance Title: Technician I, Fire Resistance �j Signature: d "-" Signature: - Date: 05/25/2016 Date: 05/25/2016 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product or service is or has ever been under an Intertek certification program. GFT-OP-11a (24-MAR-2014) //A IRONRIDGE Background All roofing products are tested and classified for their ability to resist fire Recently, these fire resistance standards were expanded to include solar equipment as part of the roof system. Specifically, this requires the modules, mounting hardware and roof covering to be tested together as a system to ensure they achieve the same fire rating as the original roof covering. These new requirements are being adopted throughout the country in 2016. IronRidge Certification IronRidge was the first company to receive a Class A Fire Rating —the highest possible rating —from Intertek Group plc., a Nationally Recognized Testing Laboratory. IronRidge Flush Mount and Tilt Mount Systems were tested on sloped and flat roofs in accordance with the new UL 1703 & UL 2703 test standards. The testing evaluated the system's ability to resist flame spread, burning material and structural damage to the roof. Refer to the table below to determine the requirements for achieving a Class A Fire Rating on your next project. Flush Mount Any Slope Tilt Mount M s 6 Degrees I Class A Fire Rating Test Setup Solar Modules Solar modules are given a Type classification based on their materials and construction. Mounting System Mounting is tested as part of a system that includes type -tested modules and fire -rated roof covering Roof Covering Roof covering products are given a Fire Class Rating of A, B or C based on their tested fire resistance. Burnin A burning wooden block is placed on module as a fan blows at 12 mph. Flame cannot be seen on underside of roof within 90 minutes. Spread of Flame Test 0 kA� Flame at southern edge of roof is aimed up the roof as a fan blows at 12 mph. The flame cannot spread 6 feet or more in 10 minutes. Type 1, 2, & 3 1 Class A Type 1, 2, & 3 1 Class A 'Class A rated PV systems can be installed on Class A, B, and C roofs. CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. W W ON U W o Z 00 W F— Cr Cf) Q LU C0 � Q Z W Q J O LU W CLASS A FIRE RATING idri,1141rA 1 CLASS A FIRE RATING DATASHEET V-10 PV_1 0 SCALE: NTS Ia*IW DM Attn: Corey Geiger, COO, IronRidge Inc. Date: September 711, 2021 Re: Structural Certification and Span Tables for the IronRidge Flush Mount System 28357 Industrial Blvd. Hayward, CA 94545 1-800-227-9523 IronRidge.com This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System. The contents of the letter shall be read in its entirety before applying to any project design. The Flush Mount System is a proprietary rooftop mounting system used to support photovoltaic (PV) modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails and secured to the rails with IronRidge mounting clamps. The XR Rails are side mounted to a selected roof attachment with 3/8" stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core components are shown in Exhibit EX-0015. The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards listed below, for the load conditions and configurations tabulated in the attached span tables. • ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures (ASCE 7-16) • 2018 International Building Code (IBC-2018) • 2018 Washington State Building Code • 2015 Aluminum Design Manual (ADM-2015) • Report SEAOC (Structural Engineer Association of California) PV2-2017 Wind Design for Solar Arrays The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B, C, & D, roof zones provided in ASCE 7-16 for gable & hip roof profiles, and roof slopes of 8° to 45°. The tabulated spans are applicable when the following conditions are met: 1. Span is the distance between two adjacent roof attachment points (measured at the center of the attachment fastener). 2. Each module shall be supported by 2 rails (2 rail system) or 3 rails (3 rail system). Spans are calculated based on 2 rail systems, and conservatively deemed acceptable for 3 rail systems. 3. The underlying roof slope, measured between the roof surface and horizontal plane, is 80 to 450. 4. The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from grade, does not exceed 30 feet. 5. A clearance from the underside of the array to the roof surface of 2" minimum shall be provided and the height of the array, the distance from the module top surface to the roof surface (defined as h2), shall not exceed 10". 6. Module length and area shall not exceed the maximum values listed on the respective span tables. 7. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Mount Installation Manual and other applicable standards for the general roof construction practice. © 2021 IronRidge, Inc. WA Flush Mount System Certification Letter - 1 /%r IRONRIDGE 28357 Industrial Blvd. Hayward, CA 94545 1-800-227-9523 IronRidge.com The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules, or the underlying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. Sincerely, Gang Xuan, PE Senior Structural Engineer © 2021 IronRidge, Inc. �w�F tv,i ci`il \ i 33 0. fF9 r�G'lSTtRE� 2021.09.07 15:55:03 -07'00' WA Flush Mount System Certification Letter - 4 1 STATE OF WASHINGTON ENGINEERING LETTER (IRON RIDGE RACKING) V-11 SCALE: NTS CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. Sri w v J U:) M LU Of W Z W W ON z�00 CD Cf) Q LU C0 � Q Z W O �o LU W ENGINEERING LETTER Id 141VA PV-1 1 UFO Family of Components /A IRONRIDGE Simplified Grounding for Every Application The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules directly to IronRidge XR Rails. All system types that feature the UFO family —Flush Mount, Tilt Mount and Ground Mount —are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations. System Diagram ------------------m----------- --- -- ------------------ m--- --------- --- -- ------------------m----------- --- -- O UFO C Stopper Sleeve • Grounding Lug m Bonded Splice Ground Wire V Approved Enphase microinverters can provide equipment grounding of IronRidge systems, eliminating the need for grounding lugs and field installed equipment ground conductors (EGC). A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. UL Certification The IronRidge Flush Mount, Tilt Mount, and Ground Mount Systems have been listed to UL 2703 by Intertek Group plc. UL 2703 is the standard for evaluating solar mounting systems. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. QGo to IronRidge.conn/UFO XR Rails d .I XR1000 Only UFO/Stopper Bonded Splice d d N/A Grounding Lugs 1 per Row 1 per Row 1 per Array Microinverters Enphase - M250-72, M250-60, M215-60, C250-72 & Power Darfon - MIG240, MIG300, G320, G640 Optimizers SolarEdge - P300, P320, P400, P405, P600, P700, P730 Fire Rating Class A Class A N/A Modules Tested or Evaluated with over 400 Framed Modules Refer to installation manuals for a detailed list. WZAE 1 GROUNDING DETAILS IRON RIDGE RACKING) V-12 SCALE: NTS CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. LO W C/:) C/3 M W Z W W ON U w o Z 0:� 00 W F— Cr co Q LJJ C/) � Q Z w O o � w GROUNDING DETAILS idb,11,111A 6 6.75 [172]� LI I`tJ 7.50 [191]� n '�• '�I ` l �( 1, ( 1 .28 [7] (3 HOLES) C )CKOUTS A,B,C,D KNOCKOUTS NOTES: FINISH - GRAY BAKED ENAMEL ELECTRODEPOSITIED OVER CLEANED PHOSPHATIZED STEEL. UL LISTED - FILE E-2875 ALL NEUTRALS - INSULATED GROUNDABLE SUITABLE FOR USE AS SERVICE EQUIPMENT TOP OF NEMA TYPE 3R SWITCHES HAVE PROVISIONS FOR MAXIMUM 2 1/2" BOLT -ON HUB. SHORT CIRCUIT CURRENT RATINGS: • 10,000 AMPERES. 10,000 AMPERES WHEN USED WITH OR PROTECTED BY CLASS H OR K FUSES. 100,000 AMPERES WITH CLASS R FUSES. * FOR CORNER GROUNDED DELTA SYSTEMS. ■ PLUG FUSES $ LUGS SUITABLE FOR 60-C OR 75' CONDUCTORS. FEBRUARY 2014 LII/J NEMA TYPE 3R ILLUSTRATED A,B,C KNOCKOUTS WIRING DIAGRAMS FUSIBLE NOT FUSIBLE I I A C S N I I I p p p B D � f b SN TERMINAL LUGS $ AMPERES MAX. WIRE MIN. WIRE TYPE 30 # 6 AWG # 12 AWG AL # 6 AWG # 14 AWG CU KNOCKOUTS SYMBOL A B C D CONDUIT SIZE .50 .75 1 1.25 DUAL DIMENSIONS: INCHES MILLIMETERS CATALOG NUMBER VOTAGE RATINGS WIRING DIAG. HORSEPOWER RATINGS 120VAC 240VAC STD. MAX. STD. MAX. 10 10 10 30 10 30 D211NRB• ■ D221NRB D321NRB 240VAC 240VAC 240VAC A A B C D 1/2 - - - - 2 - - - - 1 1/2 1 1/2 1 1/2 - - - 3* 3 - - 3 3 3 3 3 - 7 1/2* 7 1/2 - 7 1/2 DU221R6 I 240VAC DU321RB 240VAC REF DWG #1852 1 AC DISCONNECT DATASHEET V-13 SCALE: NTS CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. Lo W C/:) C/3 W Z W w oN Z o:f 00 W F— (:D cf) Q Lu C/D � C/) � Q Z W 0 J O Lu W AC DISCONNECT Id 0,1VA PV-1 3 CERTIFICATE OF COMPLIANCE Certificate Number E341165 Report Reference E341165-20171030 Issue Date 2020-JANUARY-22 Issued to: Enphase Energy Inc 1420 N McDowell Blvd Petaluma, CA 94954-6515 This certificate confirms that Static Inverters, Converters and Accessories for Use in representative samples of Independent Power Systems; Photovoltaic Rapid Shutdown System Equipment Refer to the Addendum Page for Models Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: UL 62109-1, Power Converters for Use in Photovoltaic Power Systems - Part 1: General Requirements UL 1741, Inverters, Converters, Controllers and Interconnection System Equipment for Use with Distributed Energy Resources (Utility Interaction requirements) CAN/CSA C22.2 No. 107.1-01, General Use Power Supplies Additional Information: See the UL Online Certifications Directory at https://ig.ulprospector.com for additional information. This Certificate of Compliance does not provide authorization to apply the UL Mark. Only the UL Follow -Up Services Procedure provides authorization to apply the UL Mark. Only those products bearing the UL Mark should be considered as being UL Certified and covered under UL's Follow -Up Services. Look for the UL Certification Mark on the product. CERTIFICATE OF COMPLIANCE Certificate Number E341165 Report Reference E341165-20171030 Issue Date 2020-JANUARY-22 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. Permanently -connected, Grid Support utility Interactive, 208V single-phase, 240V single phase evaluated for use on a split phase system, distributed resource power system. Models IQ7-60, IQ7PLUS-72, IQ7X-96, IQ7XS-96, may be f/b -2, -5, -E, or -ACM, f/b -US, may be f/b - NM, may be f/b -RMA&. Models IQ7A, may be f/b S, may be f/b -66 or -72, may be f/b -2, -5, -E, or -ACM, f/b -US, may be f/b - NM, may be f/b -RMA&. Models IQ7PD-72-2-US& and IQ7PD-84-2-US&. Where "&" designates additional characters not affecting safety Photovoltaic Rapid Shutdown Equipment. Models IQ7-60, IQ7PLUS-72, IQ7X-96, IQ7XS-96, may be f/b -2, -5, -E, or -ACM, f/b -US, may be f/b - NM, may be f/b -RMA&. Models 1Q7A, may be f/b S, may be f/b -66 or -72, may be f/b -2, -5, -E, or -ACM, f/b -US, may be f/b - NM, may be f/b -RMA&. Models IQ7PD-72-2-US& and IQ7PD-84-2-US&. Where "&" designates additional characters not affecting safety CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. LO W C/:) C/3 M W Z W W ON U W o Z Qf 00 W i— Cr Cn Q LU Cf) � Q Z W 0 o LU W mcgl-su ZZA u UL LISTING Bruce Mahrenholz, Director North American Certification P11g1mn Bruce Mahrenholz, Director North American Certification Program UL LLC UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any auth.,i..d licensee of UL. For questions, please Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at htto:/lul.comlaboutulllocationsl contact a local UL Customer Service Representative at htlo:llul.comlaboutulllocmions/ Page 1 of 2 Page 2 of 2 i PROJECT NO: GSD-20220421-175617 nnAIA INI nv. -A 1 ENPHASE UL LISTING CERTIFICATION MICROINVERTER) V-14 SCALE: NTS Enphase®Energy // Rapid Shutdown Rapid shutdown is built-in The 2014 and 2017 editions of the National Electrical Code (NEC 2014/NEC What's new in Section 690.12? 2017) added new rapid shutdown requirements for PV systems installed on NEC 2014/2017, Section 690.12 applies buildings. Enphase Microinverters fully meet rapid shutdown requirements in to PV conductors over 10 feet from the new code without the need to install any additional electrical equipment. the PV array and requires that the conductors power down to 30 volts and 240 volt-amperes within 10 seconds of rapid shutdown initiation. String inverters require work arounds for rapid shutdown Work around. Specialized Rapid Shutdow electrical box installed on tY roof within 10 feet of array. Work around. Shutoff switch that is easily accessible to first responders on the ground. Work around. Extra conduit in installation. Residential String Inverter Work around. String inverter installed on roof, a hostile environment that string inverters are not built to live in. Commercial String Inverter Enphase comes standard with rapid shutdown capability All Enphase microin- verters, even those that were previously installed, inherently meet rapid shutdown requirements, no additional equipment or workarounds needed Residential Microinverter To learn more, visit enphase.com Enphase microinverters can safely shut down automatically, leaving only low -voltage DC electricity isolated to the PV module Commercial Microinverter On ENPHASE 1 RAPID SHUTDOWN DATASHEET V-15 SCALE: NTS CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. 0 LO w C/:) C/3 C9 W Z W W ON z�00 W I— Cr oCf)Q LU C/) � Q Z W O J �o LU W RAPID SHUTDOWN M7:11� PV-1 5