REVIEWED BLD RESUB 1 BLD2021-0332+Structural_Analysis_or_Calculations+4.5.2021_10.36.03_AM+2127165BURT ENGINEERING April 1, 2021 City of Edmonds Building Division Edmonds, WA 98020 RE: Interior Remodel 934 Maple St Plan Check BLD2021-0332 Thank you for the careful review of the previous permit drawing submittal. 18530 MERIDIAN AVE N. SHORELINE, WA 98133 The scope of work at the Thompson residence includes a framing revision and some interior alterations. I have addressed your review comments below. Please feel free to call me directly at 206-779- 6856 to avoid further corrections that can be addressed in that manner. Responses are italicized: 1. It appears that there are drawings, details, bracing, connection details and information that can be found in the Engineer's calculation packet, that have not been depicted on the submitted plan sheet(s) for the project. Please demonstrate this information on the plans. We have submitted sheets Al-A5 addressing the plan information that was provided in my calculations onto sheets. We have also added sheet SO for general notes. 2. Please provide a foundation plan for the project. It appears that this is missing but can be found in calculation packet.. The representative foundation plan is included in the drawing set. Refer to sheet A3 3. Please provide a roof framing plan for the project. It appears that this is missing but can be found in calculation packet.. The representative roof framing plan is included in the drawing set. Refer to sheet A5. 4. Please demonstrate on the plans the structural members and their locations for the calculations you have done for this project. Refer to plan sheets AI-A5. 5. Please demonstrate on the plans the header sizes for the two newly enlarged windows and the newly enlarged door. Both of the headers are indicated on the roof framing plan on sheet A5. (2)-2x8. BkBUR T 18530 MERIDIAN AVE N. SHORELINE, WA 98133 ENGINEERING 6. Please demonstrate on the plans the Mechanical ventilation and its minimum requirements for the bathroom and kitchen. Response by architect. 7. Please provide the code cycle and any other additional ICC code references used for this project on page P1. Please keep in mind that as of February 1, 2021 Washington state has adopted the 2018 code cycle for ICC along with amendments. Response by architect, but note that our design is 2018 IBC compliant. 8. Please demonstrate on the plans, how the smoke/carbon monoxide detector(s) will be connected to the existing smoke/ carbon monoxide detector(s). Response by architect. 9. It appears that there is an existing and proposed floor plan found on AI and A2. For better clarity please provide a separate existing and proposed floor plan. It appears that the kitchen is not being remodeled as the job description in the application depicts. Response by architect. Sincerely, BURT ENGINEERING PLLC Cornell E. Burt, P.E. President Cc: File BURT ENGINEERING Structural Calculations Supplemental Thompson Residence 934 Maple St Edmonds, WA 98020 BE Project # 21026 April 1, 2021 2018 International Building Code 18530 MERIDIAN AVE N. SHORELINE. WA 98133 BURT ENGINEERING NGINEERING PROJECT 4 P� UAl 1 �T SUBJECT A �1'n l? I T)M v.AID�, �•A STRUCTURAL ENGINEERING BUILDING CODE CONSULTING PROJECT # Z Z 6 DATE Y 2( SHEET OF By C 8 Cap✓���� ���c4��tf��� s ; 5 G F vvT PLf- BURT ENGINEERING PLLC 18530 Meridian Ave N Shoreline, WA 98133 206-779-6856 cb@burtengineering.com Wood Beam DESCRIPTION: 6' header at roof CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: ASCE 7-16 Material Properties Project Title: Engineer: Project ID: Project Descr: Analysis Method: Allowable Stress Design Fb + Load Combination ASCE 7-16 Fb - Fc - Prll Wood Species : Douglas Fir -Larch Fc - Perp Wood Grade : No.2 Fv Ft Beam Bracing : Beam is Fully Braced against lateral -torsional buckling e 2-2x8 Span = 6.50 ft Software Printed: 1 APR 2021, 8:43AM File: Thompson.ec6 INC. 1983-2020. Build:12.20.8.17 900 psi E : Modulus of Elasticity 900 psi Ebend- xx 1600 ksi 1350 psi Eminbend - xx 580 ksi 625 psi 180 psi 575 psi Density 31.21 pcf Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.0150, S = 0.0250 ksf, Tributary Width = 4.0 fl DESIGN SUMMARY • Maximum Bending Stress Ratio = 0.311: 1 Maximum Shear Stress Ratio = 0.142 : 1 Section used for this span 2-2x8 Section used for this span 2-2x8 fb: Actual = 385.83psi fv: Actual = 29.32 psi Fb: Allowable = 1,242.00 psi Fv: Allowable = 207.00 psi Load Combination +D+S Load Combination +D+S Location of maximum on span = 3.250ft Location of maximum on span = 5.907 ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.027 in Ratio = 2943>=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.042 in Ratio = 1839>=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C i Cr C m C t C L M fb F'b V fv F'v D Only 0.00 0.00 0.00 0.00 Length = 6.50 ft 1 0.149 0.068 0.90 1.200 1.00 1.00 1.00 1.00 1.00 0.32 144.68 972.00 0.16 10.99 162.00 +D+S 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.50 ft 1 0.311 0.142 1.15 1.200 1.00 1.00 1.00 1.00 1.00 0.85 385.83 1242.00 0.43 29.32 207.00 +D+0.750S 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.50 ft 1 0.262 0.120 1.15 1.200 1.00 1.00 1.00 1.00 1.00 0.71 325.54 1242.00 0.36 24.74 207.00 +0.60D 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.50 ft 1 0.050 0.023 1.60 1.200 1.00 1.00 1.00 1.00 1.00 0.19 86.81 1728.00 0.10 6.60 288.00 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+S 1 0.0424 3.274 0.0000 0.000 BURT ENGINEERING PLLC 18530 Meridian Ave N Shoreline, WA 98133 206-779-6856 cb@burtengineering.com Wood Beam DESCRIPTION: 6' header at roof Vertical Reactions Project Title: Engineer: Project ID: Project Descr: Support notation : Far left is #1 Printed: 1 APR 2021, 8:43AM Software coovriaht ENERCALC. INC.1983-2020. Build:12.20.8.17 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.520 0.520 Overall MINimum 0.325 0.325 D Only 0.195 0.195 +D+S 0.520 0.520 +D+0.750S 0.439 0.439 +0.60D 0.117 0.117 S Only 0.325 0.325