Loading...
APPROVED ENG PLN_BLD2022-0188+Architectural_Plan+2.11.2022_1.18.15_PM+2676452T/ I� I� 4�I'`. `�i PHOTO AT AREA OF WO AO NOT TO SCALE Approved by Fire 02/28/2022 APRA ��ffi avav Any alterations to fire alarm will require a separate permit. Address visible from parking area. Fire Alarm service and entry BRACKETT APARTM E P 9501 244TH St. SW Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way Edmonds, WA per city standards that is caused or occurs during the permitted project. Catwalk Repairs Buildih into Tegris will need to be ALL WORK SUBJECT APPROVED ENGINEERING DIVISION d onds u 4rtment iR R. ADECKING, RAILING, V �Y ST SW x y APTS Iding OfficialErir- Ccwivt r Permit Number; BLD2022-0188 fin.al. TO FIELD PLANS MUST BE APPROVED AS NOTED WORK INSPECTION FOR C r CODE COMPLIANCE ON JOB SITE 03/08/2022 THE FOLLOWING SCOPE OF WORK AND DRAWINGS SHALL PROVIDE GUIDELINES FOR REPAIRS TO THE EXTERIOR "CATWALK" LANDING AND STAIRS FOUND AT BUILDING I OF THE BRACKETT APARTMENT COMPLEX. DUE TO THE IMPORTANCE OF REPAIRING THIS WALKWAY FOR EXITING, SOME OF THE WORK HAS ALREADY TAKEN PLACE. THE INTENT OF THIS DOCUMENT IS TO CONFIRM THE REPAIR WORK MEETS THE INTENT OF THE APPLICABLE BUILDING CODE AS FOLLOWS: 220018 INTERNATIONAL EXISTING BUILDING CODE (IBC) SECTIONS: 50 SCOPE. THE WORK PERFORMED ON AN EXISTING BUILDING SHALL BE CLASSIFIED IN ACCORDANCE WITH THIS CHAPTER s-"- .2 WORK AREA. WORK AREA SHALL BE DEFINED ON THE CONSTRUCTION DOCUMENTS. 5011 SCOPE. LE EL 1 ALTERATIONS INCLUDE THE REMOVAL AND REPLACEMENT OR THE COVERING OF EXISTING MATERIALS, ELEMENTS, OR FIXTURES USING NEW MA TERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES THAT SERVE THE SAME PURPOSE. ClkPTER 7: ALTERATIONS - LEVEL 1 701.2 CONFORMANCE: T� EXISTING BUILDING SHALL NOT BE ALTERED SUCH THAT THE BUILDING BECOMES LESS SAFE THAN ITS EXISTING CONDITION 70 .1 MEANS OF EGRESS AL 'ERATIONS DONE TO THIS PROJECT WILL MAINTAIN THE LEVEL OF PROTECTION FOR THE EXISTING MEANS OF EGRESS 1. 2. 3. NING 4 SITE MAP BUILDING AO NOT TO SCALE N1 6. 7. 8. 9. 10 11 E SCOPE OF WORK FOR THIS REPAIR PROJECT IS GENERALLY DESCRIBED BELOW AND ON ATTACHED DRAWINGS. REPLACE WATER DAMAGED 4X12 BEAM WITH NEW BEAM TO MATCH EXISTING (4X12 HEM/FIR #2) PROVIDE NEW 2X12 HEM/FIR #2 JOISTS ADJACENT TO EXISTING 2X12 JOISTS REPLACE ANY DAMAGED FRAMING AT RIM AREAS WITH PRESSURE TREATED WOOD IN SIZES TO MATCH EXISTING. REPAIR AREAS OF WATER DAMAGED SHEATHING, AS NOTED ON PHOTO, WITH NEW 4" CDX SHEATHING TO MATCH EXISTING. BASIS OF DESIGN DECK COATING IS PACIFIC POLYMERS ELASTO-DECK 5001 NG BASE COAT WITH SAND BROADCAST INTO ELASTO-GLAZEAL-HT TOP COAT AND ACCESSORIES (SM7120PU SEALANTS, TIETEX t-272 REINFORCING FABRICS AND 24 GA BONDERIZED METAL EDGE FLASHINGS) PROVIDE BUTYL SELF ADHERED MEMBRANE OVER OUTER FACE OF BEAM PRIOR TO COVERING WITH EXTERIOR TRIMS REPLACE ANY DAMAGED PICKETS TO MATCH EXISTING WITH STAINLESS STEEL FASTENERS REPLACE ANY DAMAGED GUARDRAIL FRAMING TO MATCH EXISTING REPLACE SOFFIT WTIH EXTERIOR GRADE $" TYPE X GWB. PROVIDE NEW 4" CONTINUOUS SOFFIT VENTS AT ALL REPLACED SOFFITS TYP. PROVIDE DRIP EDGE L-ANGLE FLASHING UNDER PERIMETER OF OUTER RIM BOARD AS NOTED ON DRAWINGS. PRIME AND PAINT AREAS TO MATCH EXISTING, AS PER BRACKETT APARTMENT INSTRUCTIONS REGARDING PAINT MANUFACTURER AND COLOR(S). GENERAL NOTES: A. ANY VARIATIONS OR UNFORSEEN CONDITIONS SHALL BE REPORTED TO CLIENT. B. ABB SHALL REVIEW CONDITIONS WITH CONTRACTOR AND WILL PROVIDE SUBSEQUENT REPAIR DIRECTIVES WHERE REQUIRED. RECEIVED C. ALL REPLACED FRAMING AND SHEATHING SHALL MATCH EXISTING. D. FRAMING AND SHEATHING MUST BE DRY BEFORE COVERING. Feb 16 2022 OWNER/CONTRACTOR IS RESPONSIBLE FOR CITY OFEDMONDS ENT EROSION CONTROL AND DRAINAGE DEVE OPARTMENRVICES AREA OF REPAIR TO SHEATHING AND DECK COATING 1A DECK COATING REPAIR AREA All 1/4"=1'-0" EXISTING EXTERIOR WALLS EXISTING 4X12 PT 1 STRINGER WITH A2 CONCRETE TREADS REMAINS IN PLACE 11-0 I � A XI I � I I I I I I o1 I I I I I ID, I NEW CODE I I I 1 COMPLIANT HANDRAILS EACH I I I SIDE OF STEPS ex st slope I ONE SIDE SHALL a .112 1 I HAVE 1'-0" HANDRAIL (D EXTENSIONS �zI� I I 1 XIXUI I A2 w 104 O �= EXISTING 4X12 BEAM (7'� CAT WALK PLAN AT AREA OF WORK Al 1 /4"= l'-0" EXISTING 4X12 BEAM AREA OF REPAIR TO SHEATHING AND DECK COATING EXISTING 42" HIGH GUARDRAILS REPLACE EXISTING BEAM IN LIKE KIND: 4X12 HF#2 PRESSURE TREATED CANTILEVER BEAM 20 FT LENGTH REMOVE AND RESET EXISTING 42" HIGH GUARDRAILS WHERE NEW WORK IS REQUIRED 1'-01, 1 TREAD. ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE -iANDRAILS SHALL BE MINIMUM OF 1-1/4" TOMAXIMUM OF ?" OUTSIDE DIAMETER. RETURN HANDRAIL TO WALL OR BACK TO RAIL -,PER IBC 1012.5, HANDRAILS SHALL CONTINUE TO "-SLOPE FOR FOR THE DEPTH OF ONE TREAD BEYOND THE BOTTOM RISER NEW PAINTED METAL HANDRAIL WITH 1.5" MIN CLEARANCE TO WALL SURFACE STAIR TREADS PER IBC 1012.5, HANDRAILS SHALL EXTEND STAIR WITHIN STAIRWELL 12" BEYOND TOP RISER TYP. STAIR HANDRAIL GENERAL REQUIREMENTS Al 1 /4"=1'-0" RECEIVED Feb 16 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ,r. - -' Hardware and fasteners in contact with ■ preservative -treated wood shall be of hot -dipped zinc galvanized steel, ■ stainless steel, silicon bronze or copper. I In the absence of manufacturer's recommendations a minimum of ASTM A 653 type G185 zinc -coated galvanized steel, or ■ equivalent, shall be used. I IRC R317.3.1 IBC 2304.10.5.1 r— - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - I Guardrails to withstand 200# force. Infill spacing not to exceed 4". ------------------------------------ EXIST WRB AND SIDING LAP OVER EXISTING DECK COATING EXIST DECK COATING (REPLACE WHERE DAMAGED) EXIST 4" CDX PLYWOOD (REPLACE WHERE DAMAGED) SLOPE TO DRAIN — — — — — — — - — — — — — — — — — — — — — — EXIST. 2X10 RIP DOWNS MATCH EXISTING (REPLACE or SISTER WITH NEW JOISTS IF DAMAGE IS LIMITED) $" TYPE X EXTERIOR RATED GWB PROVIDE CONTINUOUS 4" STRIP VENT AT ALL SOFFIT AREAS EXIST 2X6 CAP (REPLACE WHERE DAMAGED) EXIST 2X6 (REPLACE WHERE DAMAGED) 2X2 @ 5" O.C. MATCH EXISTING (REPLACE WHERE DAMAGED) 1X4 BOARD TO MATCH EXISTING, SET VERTICALLY ? OVER 2X2. (REPLACE WHERE DAMAGED) 1 ih 2 24 GA EDGE FLASHING REPLACE BEAM WITH 4X12 PRESSURE TREATED (MATCH EXISTING SIZE) CAT WALK DETAIL SECTION A2 1 1/2" = 1'-0" COVER END OF BEAM WITH SELF ADHERED MEMBRANE BEFORE ATTACHING TRIM BOARD COVER. ALLOW FOR DRAINAGE FROM n IZ AM11r T/ M) MIXIrMTrM AIAiAX/ rM�RA MrAnn rKIM MATCH FASTENER TYPE AND SPACING OF EXISTING WHERE REPLACED 1X10 TK CEDAR BOARD -MATCH EXISTING SET HORIZONTALLY OVER 2X2'S (REPLACE WHERE DAMAGED) REPLACE ALL DAMAGED EDGE JOISTS WITH 2X PRESSURE TREATED WOOD TO MATCH EXISTING, RIPPED TO FIT. ALL CUT EDGES TO BE SEALED PROVIDE 3/4X3/4" PRE FIN GALV DRIP EDGE FLASHING SET IN CONTINOUS BEAD OF BASF-NP1 SEALANT PHOTO OF DAMAGED AREA A2 PHOTO OF DECK GUARDRARECEIVED Feb 16 2022 b� Allana, Buick & Bers, Inc. BRACKET LANDING - CAT WALK REPAIR Date: Issue: —00 300 Elliot Avenue, Suite 250 Project Location: ABBAE 02/03/22 Draft Review Set Seattle, WA. 98121 9501 244 th St. SW Project #: 227161.01 02/09/21 Contractor Issue Set r� www.abbae.com www.abbae.com Edmonds, WA, 98020 ALLANA BuICK & 9ERI3 W:\Projects\22-7161.01 Greystar-Bracket Landing Repair\05-CD \5.3 WORKING SET\5.3.1 CAD CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT A2 Detail Section