REVIEWED BLD BLD2021-0286+Structural_Calculations+2.23.2021_3.06.32_PM+2060553��NASIH & ASSOCIATES ARCHITECTS PLAN 3277 STRUCTURAL CALCULATIONS 12871 REGISTERED ARCHITECT l� EL WAYNE JOHNSON STATE OF WASHINGTON 2018 IBC FEB 1, 2021 8003 118th AVE NE Kirkland, SPA 98033 (425) 828-4117 1P1P1Y.NASH-ARCHITECTS. COM CLIENT: NASH & ASSOCIATES BEAM DESIGN DATA PROJECT: ARCHITECTS DATE: NAME: Roof Loads: LL 25 #/sf DL 15 #/sf Total 40 #r/sf Unless Noted Otherwise Floor Loads: LL 40 #/sf DL 10 #/sf Total 50 #/sf Deck Loads: LL 60 #/sf DL 10 #/sf Total 70 #/sf Soil: 1500 PSF Min. Concrete: Per IBC 18 Masonry. Per IBC 18 Steel: Per IBC 18 Wood: Per IBC 18 Nailing: Per IBC 18 4" Beam: Douglas Fir #2 fv = 180 fb = 900 PSI E = 1,600,000 6" Beam: Douglas Fir #2 fv = 170 fb = 875 PSI E = 1,300,000 Joists & Hem Fir #2 Rafters: fv = 150 fb = 850 PSI E = 1,300,000 Glu—Lam Beams: fv = 240 PSI fb = 2,400 PSI (reduced by size factor, CF•KI) E = 1,800,000 8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117 WWW. NASH—ARCHITECTS. COM PLAN 3277 BeamChek v2014 licensed to: Nash Jones Anderson Architects Reg # 6464-622 RB-1 Date: 12/08/14 Selection 4x 8 DF-L #2 _ Lu = 0.0 Ft 77-71 Conditions NDS 2012 Min Bearing Area R1= 2.B in2 R2= 2.8 in' (1.5) DL Defl= 0.05 in Data Beam Span 6.0 ft Reaction 1 LL 1089 # Reaction 2 LL 1089 # Beam Wt per ft 6.17 # Reaction 1 TL 1758 # Reaction 2 TL 1758 # Bm Wt Included 37 # Maximum V 1758 # Max Moment 2638'# Max V (Reduced) 1404 # TL Max Defl L / 240 TL Actual Defl L / 630 LL Max Defl L / 360 LL Actual Defl L / > 1000 Attributes Section Sin'} Shear (in) TL Defl jin) LL Defl Actual 30.66 25.38 0.11 0.06 Critical 27.05 11.70 0.30 0.20 Status OK OK OK OK Ratio 88% 46% 38% 30% Fb(psi) Fv si E(psi x mil Fc i Values Reference Values 900 180 1.6 625 Adjusted Values 1170 180 1.6 625 Arl�t►s�rne�?ts CF Size Factor 1.300 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Loads Uniform LL: 363 Uniform TL: 580 = A Uniform Load A� R1 = 1758 R2 = 1758 SPAN = 6 FT Uniform and partial uniform loads are Ibs per lineal ft. PLAN 3277 BeamChak v2014 licensed to: Nash Jones Anderson ArcnitecM Reg # 6464-622 B-1 Date: 12/08/14 Selection 5-1/8x 16-1/2 GLB 24F-V4 DF/DF Lu = 0.0 Ft Conditions NDS 2012 _ _ Min Bearing Area R1= 12.0 in2 R2= 12.0 in (1.5) DL Defl= 0.18 in Recom Camber- 0.28 in Data Beam Span 15.5 ft Reaction 1 LL 5293 # Reaction 2 LL 5293 # Beam Wt per ft 20.55 # Reaction 1 TL 7832 # Reaction 2 TL 7832 # Bm Wt Included 319 # Maximum V 7832 # Max Moment 30348# Max V (Reduced) 6442 # TL Max Defl L / 240 TL Actual Defl L / 422 LL Max Defl L / 360 LL Actual Defl L / 725 Attributes Section in' Shear Ins TL Defl in) LL Defl Actual 232.55 84.56 _ 0.44 0.26 Critical 151.96 40.26 0.78 0.52 Status OK OK OK OK Ratio 65% 48% 57% 50% Fb si Fv(psi) E(psi x mil Fcl i Values Reference Values 2400 240 1.8 650 Adiusted Values 2396 240 1.8 650 Adiuslments Cv Volume 0.999 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb = 0.00 Le = 0.00 _ Ft Loads Uniform LL: 683 Uniform TL: 990 = A F- Uniform Load A L R1 = 7832 R2 = 7832 SPAN =15.5FT Uniform and partial uniform loads are Ibs per lineal ft. PLAN 3277 Data A11tibutes Actual Critical Status Ratio Values A&Vmen s Loads BeamChek v2014 licensed to: Nash Jones Anderson Architects Reg # 6464-622 Date: 12/08/14 5-1/8x 12 GLB 24F-V4 DFIDF Lu = 0.0 Ft NDS 2012 Min Bearing Area R1= 2.0 inz R2= 2.0 in' (1.5) DL Defl= 0.10 in Recom Camber= 0.14 in Beam Span 15.0 ft Reaction 1 LL 750 # Reaction 2 LL 750 # Beam Wt per ft 14.94 # Reaction 1 TL 1312 # Reaction 2 TL 1312 # Bm Wt Included 224 # Maximum V 1312 # Max Moment 4920 '# Max V (Reduced) 1137 # TL Max Defl L / 240 TLActual Defl L / 990 LL Max Defl L / 360 LL Actual Defl L / >1000 Section (i_n' Shear in' TL Defl JjqL LL Def] 123.00 61.50 0.18 0.09 24.60 7.11 0.75 0.50 OK OK OK OK 20% 12% 24% 17% Fb i Fv i E(psi x mil) Fc I si Reference Values 2400 240 1.8 650 Ad'usted Values 2400 240 1.8 650 Cv Volume 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1,0000 Rb = 0.00 Le = 0.00 Ft Uniform LL: 100 Uniform TL: 160 =A Uniform Load A R1=1312 R2=1312 SPAN = 15 FT Uniform and partial uniform loads are Ibs per lineal ft. PLAN 3277 BearnChek v2014 licensed to: Nash Jones Anderson Architects Reg # 6464-622 B-3 Date: 12/08/14 Selection 5-1/8x 12 GLB 24F-V4 DF/DF Lu = 0.0 Ft Conditions NDS 2012 Min Bearing Area R1= 5.0 in2 R2= 4.6 inz (1.5) DL Defl= 0.13 in Recom Camber= 0.20 in Data Beam Span 11.0 ft Reaction 1 LL 1674 # Reaction 2 LL 1551 # Beam Wt per ft 14.94 # Reaction 1 TL 3281 # Reaction 2 TL 2986 # Bm Wt Included 164 # Maximum V 3281 # Max Moment 11839'# Max V (Reduced) 2971 # TL Max Defl L / 240 TL Actual Defl L / 577 LL Max Defl L / 360 LL Actual Defl L / >1000 Attributes Section (in") Shear (In'] TL Defl in LL Defl Actual 123.00 61.50 0.23 0.10 Critical 59.20 18.57 0.55 0.37 Status OK OK OK OK Ratio 48% 30% 42% 26% Values Adjustments _ Fb (pSQ Fv(psi E(psi x mil Fc! S Reference Values 2400 240 1.8 650 Ad'usted Values 2400 240 1.8 650 Cv Volume 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Loads Point LL Point TL Distance Par Unif LL Par Unif TL Start End 1650 B = 3023 7.0 225 H = 440 0 7.0 L H Pt loads: B R1 = 3281 R2 = 2986 SPAN = 11 FT Uniform and partial uniform loads are Ibs per lineal ft. PLAN 3277 BeamChek v2014 licensed to: Nash Jones Anderson Architects Reg # 6464-622 B-4 Date: 12/08/14 Selection 4x 10 DF-L #2 Lu = 0.0 Ft Conditions NDS 2012 Min Bearing Area R1= 3.3 inz R2= 3.3 in' (1.5) DL Defl= 0.04 in Data Beam Span 8.0 ft Reaction 1 LL 1600 # Reaction 2 LL 1600 # Beam Wt per ft 7.87 # Reaction 1 TL 2031 # Reaction 2 TL 2031 # Bm Wt Included 63 # Maximum V 2031 # Max Moment 4063# Max V (Reduced) 1640 # TL Max Deft L / 240 TL Actual Defl L / 686 LL Max Defl L / 360 LL Actual Defl L / 963 Attributes Actual Critical Status Ratio Section in' Shear in TL Defl in LL Defl 49.91 32.38 0.14 0.10 45.14 13.67 0.40 0.27 OK OK OK OK 90% 42% 35% 37% Values Reference Values Adjusted Values Adustments CIF Size Factor Cd Duration Cr Repetitive Ch Shear Stress Cm Wet Use Cl Stability Loads Fb (psi) Fv (psi) E (psi x 900 180 1.6 1080 180 1.6 1.200 1.00 1.00 1.00 N/A 1.00 1.00 1.00 1.0000 Rb = 0.00 Le = 0.00 Ft Uniform LL: 400 Uniform TL: 500 = A 625 1.00 Uniform Load A R1 = 2031 R2 = 2031 SPAN = 8 FT Uniform and partial uniform loads are Ibs per lineal ft. PLAN 3277 BeamChek v2014 licensed to: Nash Jones Anderson Architects Reg # 6464-622 B-5 Date: 12/08/14 selection 3-1/8x 12 GLB 24F-V4 DF/DF Lu = 0.0 Ft Conailt'gns NDS2012 Min Bearing Area R1= 4.6 inZ R2= 5.3 in (1.5) DL Defl= 0.07 in Recom Camber= 0.10 in Data Beam Span 8.0 ft Reaction 1 LL 2020 # Reaction 2 LL 1660 # Beam Wt per ft 9.11 # Reaction 1 TL 3011 # Reaction 2 TL 3461 # Bm Wt Included 73 # Maximum V 3461 # Max Moment 6881 '# Max V (Reduced) 3102 # TL Max Defl L / 240 TLActual Defl L / 758 LL Max Defl L / 360 LL Actual Defl L 1 >1000 Attributes Section W Shear (Inj TL Defl in) LL Defl Actual 75.00 37.50 0.13 0.06 Critical 34.40 19.39 0.40 0.27 Status OK OK OK OK Ratio 46% 52% 32% 22% Fb(psi) Fv (psi) E (psi x mil) FC L (psi) Values Reference Values 2400 240 1.8 650 Adjusted Values 2400 240 1.8 650 Adjustments Cv Volume 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Loads Point TL Distance Par Unif LL Par Unif TL Start End B = 1800 6.0 520 H = 650 0 6.0 280 1 = 350 6.0 8.0 I N _ Pt loads: R1 = 3011 R2 = 3461 SPAN = 8 FT Uniform and partial uniform loads are Ibs per lineal ft. PLAN 3277 BearnChek v2014 licensed to: Nash Jones Anderson Architects Reg # 6464-622 GB-1 Date: 12/08/14 selectr'on 3-1/8x 12 GLB 24F-V4 DF/DF Lu = 0.0 Ft Conditions NDS 2012 Data Min bearing Area K1= b.0 In` K1= 6.0 In` (1.0) UL Uetl= U.U9 In Kecom Camber= 0.14 in Beam Span 11.0 ft Reaction 1 LL 3080 # Reaction 2 LL 3080 # Beam Wt per ft 9.11 # Reaction 1 TL 3900 # Reaction 2 TL 3900 # Bm Wt Included 100 # Maximum V 3900 # Max Moment 10725 W Max V (Reduced) 3191 # TL Max Defl L / 240 TL Actual Defl L / 415 LL Max Defl L / 360 LL Actual Defl L / 581 Attributes Section in' Shear in' TL DO (Iti} Actual 75.00 37.50 0.32 Critical 53.63 19.94 0.55 Status OK L72% OK OK Ratio 53% 58% Values AAdius[rn n Loads LL Defl 0.23 0.37 OK 62% Fb(psi) Fv(psi) E i x mil)_Fc i(psi) Reference Values 2400 240 1.8 650 Adjusted Values 2400 240 1.8 650 Cv Volume 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Uniform LL: 560 Uniform TL: 700 = A Uniform Load A R1 = 3900 R2 = 3900 SPAN = 11 FT Uniform and partial uniform loads are Ibs per lineal ft. PLAN 3277 GB-2 Selection BeamChek v2014 licensed to: Nash Jones Anderson Architects Reg # 6464-622 Date: 12/08/14 5-1/8x 15 GLB 24F-V4 DF/DF Lu = 0.0 Ft Conditions NDS 2012 Min Bearing Area R1= 10.1 in R2= 10.0 inz (1.5) DL Defl= 0.08 in Recom Cambe-0.13 in Data Beam Span 11.5 ft Reaction 1 LL 4387 # Reaction 2 LL 4387 # Beam Wt per ft 18.68 # Reaction 1 TL 6534 # Reaction 2 TL 6507 # Bm Wt Included 215 # Maximum V 6534 # Max Moment 16577'# Max V (Reduced) 5186 # TL Max Defl L / 240 TL Actual Defl L / 706 LL Max Defl L / 360 LLActual Defl L / >1000 Attributes Section in' _ Shear ins TL Defl in LL Defl Actual 192.19 76.88 0.20 0.11 Critical 82.88 32.41 0.58 0.38 Status OK OK OK OK Ratio 43% 42% 34% 29% Values I Reference Values Adjusted Values 6&stments Cv Volume Cd Duration Cr Repetitive Ch Shear Stress Cm Wet Use Cl Stability Fb tpsg 2400 2400 1.000 1.00 1.00 Fv psi E (psi x mild Fcl 240 1.8 650 240 1.8 650 1.00 N/A 1.00 1.00 1.00 1.00 1.0000 Rb = 0.00 Le = 0.00 Ft Dads Uniform LL: 400 Uniform TL: 500 = A Point LL Point T1. Distance Par Unif LL Par Unif TL Start End 1089 B = 1758 2.5 363 H = 560 0 2.5 1089 C = 1758 8.5 1 = 80 2.5 8.5 363 J = 560 8.5 11.5 J _ I H Uniform Load A Pt loads: B ZN R1 = 6534 R2 = 6507 SPAN =11.5FT Uniform and partial uniform loads are Ibs per lineal ft. PLAN 3277 BeamChek v2014 licensed to: Nash Jones Anderson Architects Reg # 6464-622 GB-3 Date: 12/08/14 Ski-er,on 5-1/8x 15 GLB 24F-V4 DF/DF Lu = 0.0 Ft Conditions NDS 2012 Min Bearing Area R1= 8.3 in' R2= 8.3 in' (1.5) DL Defl= 0.24 in Recom Camber- 0.35 in Data Attributes Actual Critical Status Ratio Values Adios/rnen1,5 Beam Span 16.0 ft Reaction 1 LL Beam Wt per ft 18.68 # Reaction 1 TL Bm Wt Included 299 # Maximum V Max Moment 23566'# Max V (Reduced) TL Max Defl L / 240 TL Actual Defl LL Max Defl L / 360 LL Actual Defl 3450 # Reaction 2 LL 3750 # 5399 # Reaction 2 TL 5399 # 5399 # 4751 # L / 378 L / 708 Section (n'. Shear (in') TL Defl_ in LL Defl 192.19 76.88 0.51 0.27 117.83 29.69 0.80 0.53 OK OK OK OK 61 % 39% 63% 51 % Fb(psi) Fv(psi) E si x mil) Fc 1(psi) Reference Values 2400 240 1.8 650 Adjusted Values 2400 240 1.8 650 Cv Volume 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Loads Point TL Distance Par Unif LL Par UnifTL Start End B = 1500 6.0 400 H = 500 0 6.0 480 1 = 600 6.0 16.0 1 H Pt loads: l R1 = 5399 R2 = 5399 SPAN =16FT Uniform and partial uniform loads are Ibs per lineal ft. CLIENT H - ASSOCIATES ;ASIR 7 W I ND AND 5E 15M I G DE51 GN DATA PROJECT: C I I I T I C T S PER 2015 1 BG DATE: NAW- WIND DESIGN GRITERIA DESIGN PER A5GE 7-10 I. NOMINAL/ULTIMATE WIND SPEED V/asd / Vult 85/110 mph 2. R15K CATEGORY II 1.00 3. WIND EXPOSURE CATEGORY "B" 4. INTERNAL PRESSURE GOEFFIGENT +/-55 5. COMPONENTS AND CLADDING DE516N PRE55!RE +/- 16 psf BUILDIN65, 5TRUGTURE5, AND PARTS THEREOF SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH STRENGTH DESIGN, LOAD, AND RESISTANCE FACTOR DESIGN, ALLOWABLE 5TRE55 DESIGN, EMPIRICAL DESIGN OR GONVENTIONAL GON57RUGTION METHODS, A5 PERMITTED BY THE APPLICABLE MATERIAL CHAPTER, SECTION 1604.1 BUILDINGS, 5TRUGTURE5, AND PARTS THEREOF, SHALL BE DESIGNED TO WITHSTAND WIND LOADS AS DEFINED IN 5EGTION 1609 AND A50E 7-10 51MPLIFIED METHOD TO BE U5ED FOR WIND DESIGN PER ASGE 7-10, SECTION 27.5 (BUILDING HEIGHT 15 LESS THAN 160 FEfT) 110 MPH ULTIMATE WIND SPEED USE 19.6 PSF PER TABLE 27.6.1 "EXPOSURE B" WOOD 1?E51GN PER 5EGTION5 2304-2306. 5TRUGTURE5 USING WOOD SHEAR WALLS AND DIAPHRAGMS TO RE515T WIND, SEISMIC,, AND ALL OTHER LATERAL LOADS SHALL BE DESIGNED AND GON5TRUGTED IN AC40RDANGE WITH AF 4 PA 50PW5 AND PROVISIONS OF SECTIONS 2305-2506 5E15MIG DESIGN DATA DESIGN PER A5GE 7-10/5ECTION 1615 I. SEISMIC IMPORTANCE FACTOR le 1.00 2. SHORT PERIOD ACCELERATION 55 1.66 "see footnote at bottom of page 5.1 SECOND AGGELERATION 51 0.748 "see footnote at bottom of page 4. SITE GLASS D (default class per IBC) 5. SPECTRAL RESPONSE GOEFFIGENT 5vs OA-12 'see footnote at bottom of page 6. 5PEGTRAL RESPONSE COEFFICIENT 50, 0.748 *see footnote at bottom of page 7. SEISMIC, DESIGN CATEGORY D 8. SEISMIC, FORGE RESISTING SYSTEM PLYWOOD SHEAR WALLS a. DESIGN BASE SHEAR (see seismic calculations) 10. SEISMIC RESPONSE GOEFFIGENT Gg 0.13 11. RESPONSE MODIFICATION FACTOR R 6.5 12. ANALYSIS PROGEDURE EQUIVALENT LATERAL FORGE 15. R15K CATEGORY II THE ANCHORAGE OF WALLS SUPPORTING CONSTRUCTION SHALL BE BE DESIGNED IN AGGORDANGE WITH ASGE 7-10, 5EGTION 12.11.2 IN STRUCTURES ASSIGNED TO SEISMIC DE516N CATEGORY C-F, GOLLEGTOR ELEMENTS AND THEIR GONNEGTION5 TO VERTICAL ELEMENTS SHALL BE DESIGNED TO RE515T MAXIMUM EFFECTS A5 SPECIFIED IN A5GE 7-10, SECTION 12.102.1 BASE SHEAR V= (F= 5D5/R) W ANCHOR BOLT5: 5/8" DIA X 10", A307 OR BETTER W/ 7" MIN. EMBEDMENT. V= 1104#/BOLT • PER U565, THE MAXIMUM 5i IN THE STATE OF WA514I146TON 15 0.748. ALL SEISMIC, DESIGN VALUES USED IN THIS ANALY515 ARE BASED UPON TH15 NUMBER. SINGE 5115 LE55 THAN 0.75, THEN USE SEISMIC GATEGORY D IF R15K CATEGORY 15 I, 11, OR III 8003 118th AVE NE Kirkland, WA 98033 (425) 828-4117 WWW NASH—ARCHITECTS.COM -4-<j 91bl- -d Sid 9'461 xtiv /I 2 -4 X2i Z) a P 2 Id s w Q o O 0 0 XL(V SZ'�1 o� Z -d r j1h4d jib-ld •9 -1d i #IId LATERAL CALCULATIONS CLIENT. �-ASSOCIATES W11dD WORKSHEETPROJECT: CTS DATE:, &5 MPH/110 MPH= NOMINALNLTIMATE WIND SPEED NAtM[F; Icib P5F FRONT ELEVATION LEFT ELEVATION REAR ELEVATION RIGHT ELEVATION LOCATION TOTAL SHEAR FORCE (#) W x H x (see chart for wind pressure SHEAR WALL UNIT SHEAR SHEAR WALL 0 specified height) LENGTH (ft) (#/ft) TYPE _ lilp 9t 1399 -76 own — Ar►� _�skr 4.� 1 - - - �dv Zk�r k 19► � cup / Vf 166 PI-6," jWjjr1 32*7OF P� Z.a►��x�r4� _qA" 614 43gQ �.� 3 �Nr�x x 9f6 4 Zmi 3 ( /51 PA (0 11644 N.E. 80th St. Kirkland, WA 98033 (425) 828-4117 Fax (425) 822-1918 WWW. NASH—ARCHITECTS. COM ASSOCIATES ;JF NASH& LATERAL CALCULATIONS CLIENT: yND WORKSHEET 1\1tCHITLC PROJECT: DATE: 85 MPH/110 MPH= NOMINALALTIMATE WIND SPEED NAME: IC1.6 P5F FRONT ELEVATION LEFT ELEVATION REAR ELEVATION RIGHT ELEVATION LOCATION TOTAL SHEAR FORCE (fit} SHEAR UNIT SHEAR W x H x (see chart for wind pressure 0 specified height) WALL LENGTH (ft) SHEAR (#/ft) WALL TYPE 4 sits q+► /y� 57/ PA?1/ •� S6G 3 A 5' 11644 N.E. 80th St. Kirkland, WA 98033 (425) 828-4117 Fax (425) 822-1918 WWW. NASH—ARCHITECTS. CO NASH & ASSOCIATES Weight of Building: CLIENT: SEISMIC ANALYSIS PROJECT: DATE: NAME: i Roof Assembly Asphalt Shingles - 2.00 #/it Cedar Shakes - 2.25 #/ft Tile - 9.50 #/ft Felt - 0.15 #/it Felt - 0.15 #/ft Felt - 0.15 #/ft 1/2" Plywood - 1.50 #/it 1/2" Plywood - 1.50 #/ft 1/2' Plywood - 1.50 #/ft Trusses ® 24" o.c. - 1.75 #/ft Trusses ® 24" o.c. - 1.75 #/it Trusses ® 24" o.c. - 1.75 #/ft R-38 Insulation - 2.35 #/It R-30 Insulation - 2.25 #/ft R-30 Insulation - 2.25 #/ft 1/2" GWB Ceiling - 2.00 #/it 1/2" GWB Ceiling - 2.00 #/ft 1/2" GWB Ceiling - 2.00 #/ft Total 9.75 #/ft Total 9.90 #/ft Total 17.90 #/it Use 10.00 #/ft Use 10.00 #/ft Use 18.00 #/it let & 2nd Floor Assembly. Carpet / Pad 0.50 #/ft 3/4' T&C Plywood - 2.50 #/ft 2x10 0 16" o.c. - 2.30 #/it 1/2" GWB Ceiling - 2.00 #/ft Total 7.30 #/it Use 10.00 #/ft Interior Wall Assembly. 1/2" GWB - 2.00 #/ft 2X4 ® 16" o.c. - 1.10 #/ft 1/2" GWB - 2.00 #/it Total 5.10 #/it Use 8.00 #/ft Hardwood - 2.50 #/ft 3/4" T&G Plywood - 2.50 #/ft 2x10 ® 16' o.c. - 2.30 #/ft 1/2" GWB Ceiling - 2.00 #/it Total 9.30 #/ft Use 10.00 #/ft Exterior Wall Assembly. 3/4" Wood Siding - 2.30 #/ft 1/2" Plywood - 1.50 #/it 2x6 0 16" O.C. 1.37 #/it R-21 Insulation - 2.10 #/ft 1/2" GWB - 2.00 #/ft Total 9.27 #/ft Use 10.00 #/ft 4" Brick Veneer - + 3.20 #/ft 11644 N.E. 80th St. Kirkland, WA 98033 (425) 828-4117 Fax (425) 822-1918 WWW. NASH-ARCHITECTS. COM CLIENT: NASH&ASSOCIATES SEISMIC ANALYSIS PROJECT: _ ARC.IIITEC DATE: NAME: 2 1 SEISMIC: V = (C-) (WO (plywood) 2nd Level: L c Roof: (Asphalt / Cedar Shake) 10#/ft X ! SQ sf = o 12 °r (Tile) 18#/ft X sf = Exterior Walls: L x 10#/sf x 1/2 (h) Interior Walls: L x 8#/sf x 1/2 (11) ?owD (1� ZZOxB� TOTAL: - 3u IV If 1st Level: Roof: (1st Floor Roof) 10#/ft X 333 sf = 3 331D_ _ 2nd Floor: 10#/ft X 7&:— sf = _10 7(00 Exterior Walls: (E2) + L x 10#/sf x 1/2 (h) ■ as Syov�- 210 xjo kq,r (E1) Interior Walls: (I + L x 8#/sf x 1/2 (h) 00 0- TOTAL: 9060 Basement: 1st Floor. 10#/ft X .- _ _ sf = Exterior Walls: (E1) + L x 10#/sf x 1/2 (h) Interior Walls: (I1) + L x 8#/sf x 1/2 (h) TOTAL: - 11644 N.E. 80th St. Kirkland, WA 98033 (425) 828-4117 Fax (425) 822-1918 WWW. NASH- ARCHITECTS. COM CLIENT: _ NASH&ASSOCIATES SEISMIC ANALYSIS PROJECT: rARCI1TTP,CI'S DATE: NAME: BASE SHEAR: BASE SHEAR V= (E 5V5/R) W V= F (.9"12)/b.5= .14q 3 LEVEL 2: Wdl ♦4� -1 # x 0.149 = tO LEVEL 1: Wdl __J`1 & .5 # .# x 0.149 = /1 6 TOTAL: Wdl 56" 4 # x 0.149 = M45M (V) Level i Dead Load (Wdl) He* ht (h Moment (Wdl)(h) Shear 0 Star Fx = [(Wdl (h)TV (Wdl)}(h) Remarks 2 �uiGl � � (o Z$� Z � ��.2(rT►�i7 �r�3• z 7f i 1 110 S 15 /M 3, Z s, ar Total bu bl 1143, Z 11644 N.E. 80th St. Kirkland, WA 98033 (425) 828-4117 Fax (425) 822-1918 WWW. NASH—ARCHITECTS. COM tz ✓ LEVEL LINE LINE SHEAR LINE SHEAR TOTAL P > 1 WALL LENGTH Vmax SEISMIC (#/ft) WIND SHEAR WALL HEIGHT OVER TURNING HOLD— DOWN SHEAR WALL ABOVE FORCE REQ'd x - im CD / 76 Zy fo %ib rr A / 1, 8 34(o / ,S l S 43 7$ zz2K •nfr9 7. l/7� b 7$ �� ( / / 5 2 141S14 mir Y4i83 % 32? q ?q'43 FSA W 1 2 1� ¢ 2 if f.6 ift k2 sZ 2 "s q 3 6 Y J 51W1 a 3 it Y* f,76 �, � W( 150 CO Sf b t# N r K itK.0 file ; a y 6 S K O K lost 06 b►q$ 571 q sl 3 c4 NDIg L,� Iry6 1178 3►,7q t/.s- Z$ 2 yqz s z040 smsig CD H O H m I -- NASH & ASSOCIATES CLIENT:.. Axcf1lTLcTs SEISMIC ANALYSIS PROJECT: _. DATE: NAME: Redundancy Factor 1. Maximum allowable wall shear for p<=1 Vumax = (2)(Vaccstory)/Ab 1/2 at gs"p �- . --- . S'y 43 Z27$ �'Tr?2 2. Maximum actual shear Vmax = Largest seismic wall shear ,ski . ,Sf-f0 3. p = 2—[2(Vaccstory)/(Vumax)(Ab 1/2) Z' 1(1?,4-7 ) 7 1sw3(V?r17) 110'f4 A.Z. OULn JL. Wrkland, VITA 96033 (425) 828-4117 Fax (425) WWW NASH—ARCHITECTS.COM