Loading...
APPROVED BLD ENG PLN BLD2021-0561+Architectural_Plan+4.16.2021_11.28.17_AM+2149645City Of Edmonds Building Department Work CELL ALTERATION ------------------------------ ------------- Address 9726 EDMONDS WAY ------------------------------------------- Owner T-MOBILE ------------------------------------ ------------------------------- Approved Date , 5/19/2021 ------------------------------------------- Building Official ;� W. x :---------..---------------------------------------- Permit Number; BLD2021-0561 ' -------------------------------------- PROJECT INFORMATION SITE NAME: EDMONDS WAY/PUD/BERSCHURE SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 COUNTY: SNOHOMISH COUNTY LATITUDE: 47- 47' 25.5" N (47.79042700') LONGITUDE: 122' 21' 50.8" W (-122.36410050') GROUND ELEVATION: 327.26' AMSL STRUCTURE HEIGHT: 60'-0" (TOP OF STEEL POLE) JURISDICTION: CITY OF EDMONDS PARCEL: 00434500000100, RIGHT-OF-WAY PARCEL SIZE: 0.89 ACRES ZONING: WMU OCCUPANCY: U CONSTRUCTION INFORMATION: AREA OF CONSTRUCTION: EXISTING/NO CHANGE CONSTRUCTION TYPE: II-B PROPOSED USE: UNMANNED TELECOMMUNICATIONS FACILITY HANDICAP REQUIREMENTS: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS NOT REQUIRED TOWER OWNER: SNOPUD PO BOX 1107 EVERETT, WA 98206 PROPERTY OWNER: BERSCHAUER DIANNE MARIE 9724 EDMONDS WAY EDMONDS, WA. 98020 APPLICANT: T-MOBILE 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 PROJECT TEAM SITE ACQUISITION: PROJECT CONSULTANT RYKA CONSULTING MORRISON HERSHFIELD CORP. 5628 AIRPORT WAY S, SUITE 330 600 STEWART ST, SUITE 200 SEATTLE, WA 98108 SEATTLE, WA 98101 CONTACT: JESSICA PIERCE CONTACT: ROY LORETE PHONE: (206) 523-1941 PHONE: (206) 708-9031 r1 orete®mo rri so n h ers hf i eld. com PERMITTING: ENGINEER: RYKA CONSULTING G. LANCE COOKE 5628 AIRPORT WAY S, SUITE 330 MORRISON HERSHFIELD CORP. SEATTLE, WA 98108 PHONE (503) 595-9128 CONTACT: CHRISTINE CONTRERAS Icookesmorrisonhershfield.com PHONE: (206) 523-1941 ccontrera s®ryka consu Iti n g. com T—MOBILE CONSTRUCTION MANAGER ARCHITECT: T—MOBILE ROBERT LARA CONTACT: WALTER DARBY MORRISON HERSHFIELD CORP. PHONE:(425) 279-3533 PHONE (954) 577-4655 APPROVED OBTAIN ELECTRICAL ALL WORK SUBJECT PLANS MUST BE PERMIT FROM TO FIELD ■ ON JOB SITE STATE LABOR & INSPECTION FOR �M0 ®_= INDUSTRIES CODE COMPLIANCE SoI e 19807 NORTH CREEK PKWV N ® ■® BOTHELL, WA 98011 _ 1 APPROVED BY PLANNING RYKA, CONSUL T.NG SITE NAME: EDMONDS WAY/PUD/BERSCHURE ai �(o I SITE ADDRESS: T-MOBILE SITE NUMBER: PROJECT: VICINITY MAP 6 P=Sp�.lan [huh - � i . f�nc.d,NmondA �s renew ti r Ieq Y' - � .renia i 3 ' ° ' .,� w vlEdmndi O9��r.n'.YAniy.c Pair Sn n.nun'9 SSV--SI S* TRC:2S" .Eddprd�iy�. �} KC' tea. Al rAali•�momif H'engxe C7yM� Q F.eC-6[ hkOnn�dfs� nn JnroMi%.ick' •'n Ed!—d. w+ FaWe ■ sent-W-h a�uwrr� cu�c� PW® �W.'e�a•.'uvrPn UIe P,�„cJ"�ade �w.wda•�p Cn1a �Ihufla� � i na.rw SITE �.0 sa i [ � rWM.�MCiA IAlrm�v •,� .n... ,• �CwFcucOwch a Voprml ; 95011V IA4Kgh5ch" SCOPE OF WORK T—MOBILE PROPOSES TO MODIFY AN EXISTING UNMANNED TELECOMMUNICATIONS FACILITY WITH THE FOLLOWING: TOWER SCOPE: • REPLACE (2) HEX W/ (2) OCTOS • INSTALL (2) AEHC ACTIVE ANTENNA/RADIO • REMOVE (2) FRIG & (2) FXFB UTILITY NOTE: • INSTALL (2) AHFIG, (2) AH LOA SEE UTILITY SCOPE OF WORK & • REMOVE (1) HCS 1.0 CABLE POWER SURVEY/UCR BY • REMOVE (1) COVP OTHERS, UNDER SEPARATE • REMOVE ALL DIPLEXERS COVER, TO BE INCLUDED IN NTP • REMOVE ALL TMA's & UNDER SEPARATE ELECTRICAL • REMOVE (8) 7/8" COAX PERMIT IF REQUIRED. • INSTALL (2) HCS 2.0 CABLES W/PENDANTS GROUND SCOPE: • UPGRADE POWER TO 200A • REMOVE (1) PURCELL RAC72, (1) ULTRASITE & (1) FCOA CABINET • REPLACE TECH LIGHT • INSTALL (1) PURCELL HPL3 600A DC POWER CABINET & (1) HPL3 BATTERY CABINET W/ 4 STRING BATTERIES • INSTALL (1) CSR IXRE ROUTER (1) NEW FSMF, (2) AMIA W/ BASEBAND MODULES PER RFDS & VOLTAGE BOOSTER IN HPL3 • REPLACE TELCO BOX W/ AAV CUBE; RELOCATE LEC ROUTER TO AAV (PER UTILITY NOTE) • INSTALL ICE BRIDGE & NEW CONDUIT PER PLAN DESIGN BASED ON: RFDS ANCHOR VERSION 4, DATED 01/15/2021 3:48:16 PM 9726 EDMONDS WAY EDMONDS, WA 98020 SE01632A ANCHOR DIRECTIONS DIRECTIONS TO SITE (FROM T-MOBILE OFFICE, BOTHELL, WA): HEAD SOUTH TOWARD WA-527 S TURN LEFT TOWARD WA-527 S TURN RIGHT ONTO WA-527 S TURN RIGHT TO MERGE WITH 1-405 N TOWARD LYNNWOOD MERGE WITH 1-405 N TAKE THE INTERSTATE 5 S EXIT TOWARD SEATTLE/LYNNWOOD KEEP LEFT, FOLLOW SIGNS FOR 1-5 S AND MERGE ONTO 1-5 S TAKE EXIT 177 TO MERGE WITH WA-104 W/NE 205TH ST/LAKE BALLINGER WAY TOWARD EDMONDS MERGE WITH WA-104 W/NE 205TH ST/LAKE BALLINGER WAY CONTINUE TO FOLLOW WA-104 W DESTINATION WILL BE ON THE LEFT APPROVALS APPROVAL SIGNATURE DATE PROJECT MANAGER T-MOBILE RF ENGINEER SITE ACQUISITION CONSTRUCTION MANAGER SITE OWNER T-MOBILE DEVELOPMENT MANAGER T-MOBILE CONSTRUCTION MANAGER T-MOBILE OPS MANAGER T-MOBILE REGULATORY REVIEW T-MOBILE PROJECT MANAGER May 21 2021 ENGINEERING DIVISION APPROVED AS NOTED W� 05/08/2021 ROW ENG2021-0140 INDEX OF DRAWINGS SHEET DESCRIPTION TITLE SHEET GENERAL NOTES SITE PLAN ENLARGED SITE PLAN EQUIPMENT PLANS T-1 T-2 A-1 A-1.1 A-1.2 A-2 TOWER PROFILES A-3 CONSTRUCTION DETAILS A-4 CONSTRUCTION DETAILS A-5 CONSTRUCTION DETAILS A-6 CONSTRUCTION DETAILS A-7 CONSTRUCTION DETAILS A-8 CONSTRUCTION DETAILS RF-1 ANTENNA CONFIGURATION RF-2 PLUMBING DIAGRAM RF-3 TYPICAL SECTOR SFP E-1 EQUIPMENT ELECTRICAL/GROUNDING PLAN E-2 WIRING DIAGRAMS E-3 WIRING DIAGRAMS E-4 ANTENNA GROUNDING SCHEMATIC E-5 GROUNDING DETAILS CODE COMPLIANCE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT CONDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: WASHINGTON STATE AND LOCAL BUILDING CODES WITH THE FOLLOWING REFERENCE CODE: 2018 INTERNATIONAL BUILDING CODE (IBC) 2018 INTERNATIONAL MECHANICAL CODE (IMC) 2018 INTERNATIONAL FIRE CODE (IFC) 2020 NATIONAL ELECTRIC CODE (NFPA 70) a CONTRACTOR TO CALL TO VERIFY UTILITIES AT Q Q LEAST TWO WORKING DAYS PRIOR TO DIGGING Know what's below. Call before you dig. DO NOT SCALE DRAWINGS CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ARCHITECT OR ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 v .morrlsonhemhfield.com MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 SOX REVIEW SA 0 02/22/21 10096 FINAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: EDMONDS WAY/PUD/ BERSCHURE T-MOBILE SITE I.D. SE01632A SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 SHEET NAME: RECEIVE TITLE �HE95T202 SHEET NUMBER: DEPARTMENT T-1 C J ARCHITECTURAL GENERAL NOTES ELECTRICAL GENERAL NOTES COMPOUND NOTES 1. WORK SHALL COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. ALL NECESSARY LICENSES, CERTIFICATES, ETC., REQUIRED BY AUTHORITY HAVING JURISDICTION SHALL BE PROCURED AND PAID FOR BY THE CONTRACTOR. 2. THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING DIMENSIONS AND CONDITIONS AT THE JOB SITE WHICH COULD AFFECT THE WORK UNDER THIS CONTRACT. ALL MANUFACTURERS RECOMMENDED SPECIFICATIONS, EXCEPT THOSE SPECIFICATIONS HEREIN, WHERE MOST STRINGENT SHALL BE COMPLIED WITH. 3. THE CONTRACTOR SHALL VERIFY THAT NO CONFLICTS EXIST BETWEEN THE LOCATIONS OF ANY AND ALL MECHANICAL, ELECTRICAL, PLUMBING, OR STRUCTURAL ELEMENTS, AND THAT ALL REQUIRED CLEARANCES FOR INSTALLATION AND MAINTENANCE ARE MET. NOTIFY THE CONSULTANT OF ANY CONFLICTS. THE CONSULTANT HAS THE RIGHT TO MAKE MINOR MODIFICATIONS IN THE DESIGN OF THE CONTRACT WITHOUT THE CONTRACTOR GETTING ADDITIONAL COMPENSATION. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAILY CLEAN UP OF ALL TRADES AND REMOVE ALL DEBRIS FROM THE CONSTRUCTION SITE. AT THE COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL THOROUGHLY CLEAN THE BUILDING, SITE, AND ANY OTHER SURROUNDING AREAS TO A BETTER THAN NEW CONDITION. 5. THE CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE, ETC. ACCORDING TO APPLICABLE CODES, STANDARDS, AND GOOD CONSTRUCTION PRACTICES. 6. WHERE ONE DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY FOR ALL LIKE OR SIMILAR CONDITIONS, EVEN THOUGH NOT SPECIFICALLY MARKED ON THE DRAWINGS OR REFERRED TO IN THE SPECIFICATIONS, UNLESS NOTED OTHERWISE. 7. WHERE NEW PAVING, CONCRETE SIDEWALKS OR PATHS MEET EXISTING CONSTRUCTION, THE CONTRACTOR SHALL MATCH THE EXISTING PITCH, GRADE, AND ELEVATION SO THE ENTIRE STRUCTURE SHALL HAVE A SMOOTH TRANSITION. 8. THE GENERAL CONTRACTOR SHALL OBTAIN WRITTEN CONFIRMATION OF THE EXPECTED DATE OF COMPLETION OF THE POWER CONNECTION FROM THE POWER COMPANY. 9. IF THE POWER COMPANY IS UNABLE TO PROVIDE THE POWER CONNECTION BY OWNER'S REQUIRED DATE, THE GENERAL CONTRACTOR SHALL PROVIDE AND MAINTAIN A TEMPORARY GENERATOR UNTIL THE POWER COMPANY CONNECTION IS COMPLETED. COSTS ASSOCIATED WITH THE TEMPORARY GENERATOR TO BE APPROVED BY THE OWNER. 10. PLANS PART OF THIS SET ARE COMPLEMENTARY. INFORMATION IS NOT LIMITED TO ONE PLAN. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT, WHETHER THE PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. THEY ARE NOT TO BE USED BY THE OWNER ON OTHER PROJECTS OR EXTENSION TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO MORRISON HERSHFIELD. THESE PLANS WERE PREPARED TO BE SUBMITTED TO GOVERNMENTAL BUILDING AUTHORITIES FOR REVIEW FOR COMPLIANCE WITH APPLICABLE CODES AND IT IS THE SOLE RESPONSIBILITY OF THE OWNER AND/OR CONTRACTOR TO BUILD ACCORDING TO APPLICABLE BUILDING CODES. 11. IF CONTRACTOR OR SUB -CONTRACTOR FIND IT NECESSARY TO DEVIATE FROM ORIGINAL APPROVED PLANS, THEN IT IS THE CONTRACTOR'S AND THE SUB -CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE ARCHITECT WITH (4) COPIES OF THE PROPOSED CHANGES FOR HIS APPROVAL BEFORE PROCEEDING WITH THE WORK. IN ADDITION THE CONTRACTOR AND SUB -CONTRACTORS SHALL BE RESPONSIBLE FOR PROCURING ALL NECESSARY APPROVALS FROM THE BUILDING AUTHORITIES FOR THE PROPOSED CHANGES BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR AND SUB -CONTRACTORS SHALL BE RESPONSIBLE FOR PROCURING ALL NECESSARY INSPECTIONS AND APPROVALS FROM BUILDING AUTHORITIES DURING THE EXECUTION OF THE WORK. 12. IN EVERY EVENT, THESE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS SHALL BE INTERPRETED TO BE A MINIMUM ACCEPTABLE MEANS OF CONSTRUCTION BUT THIS SHALL NOT RELIEVE THE CONTRACTOR, SUB -CONTRACTOR, AND/OR SUPPLIER/MANUFACTURER FROM PROVIDING A COMPLETE AND CORRECT JOB WHEN ADDITIONAL ITEMS ARE REQUIRED TO THE MINIMUM SPECIFICATION. IF ANY ITEMS NEED TO EXCEED THESE MINIMUM SPECIFICATIONS TO PROVIDE A COMPLETE, ADEQUATE AND SAFE WORKING CONDITION, THEN IT SHALL BE THE DEEMED AND UNDERSTOOD TO BE INCLUDED IN THE DRAWINGS. FOR EXAMPLE, IF AN ITEM AND/OR PIECE OF EQUIPMENT REQUIRES A LARGER WIRE SIZE (I.E. ELECTRICAL WIRE), STRONGER OR LARGER PIPING, INCREASED QUANTITY (I.E. STRUCTURAL ELEMENTS), REDUCED SPACING, AND/OR INCREASED LENGTH (I.E. BOLT LENGTHS, BAR LENGTHS) THEN IT SHALL BE DEEMED AND UNDERSTOOD TO BE INCLUDED IN THE BID/PROPOSAL. THESE DOCUMENTS ARE MEANT AS A GUIDE AND ALL ITEMS REASONABLY INFERRED SHALL BE DEEMED TO BE INCLUDED. 13. THESE CONTRACT DOCUMENTS AND SPECIFICATIONS SHALL NOT BE CONSTRUED TO CREATE A CONTRACTUAL RELATIONSHIP OF ANY KIND BETWEEN THE ARCHITECT AND THE CONTRACTOR. A. GENERAL 1. EXAMINE THE SITE CONDITIONS VERY CAREFULLY AND THE SCOPE OF PROPOSED WORK TOGETHER WITH THE WORK OF ALL OTHER TRADES AND INCLUDE IN THE BID PRICE ALL COSTS FOR WORK SUCH AS EQUIPMENT AND WIRING MADE NECESSARY TO ACCOMMODATE THE ELECTRICAL SYSTEMS SHOWN AND SYSTEMS OF OTHER TRADES. 2. OBTAIN ALL PERMITS, PAY ASSOCIATED FEES AND SCHEDULE INSPECTION. 3. PROVIDE ALL LABOR, MATERIAL, EQUIPMENT, INSURANCE, AND SERVICES TO COMPLETE THIS PROJECT IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND PRESENT IT AS FULLY OPERATIONAL TO THE SATISFACTION OF T-MOBILE & LAND/TOWER OWNER 4. PRIOR TO BEGINNING WORK COORDINATE ALL POWER AND TELCO WORK WITH THE LOCAL UTILITY COMPANY AS IT MAY APPLY TO THIS SITE. ALL WORK TO COMPLY WITH THE RULES AND REGULATIONS OF THE UTILITIES INVOLVED GENERAL CONTRACTOR IS RESPONSIBLE FOR VED. REQUESTING CONNECTION OF COMMERCIAL POWER FROM THE POWER COMPANY. ELECTRICAL CONTRACTOR SHALL COORDINATE THIS WORK WITH THE GENERAL CONTRACTOR. 5. FABRICATION AND INSTALLATION OF THE COMPLETE ELECTRICAL SYSTEM SHALL BE DONE IN A FIRST CLASS WORKMANSHIP PER NECA STANDARD 1-2000 BY QUALIFIED PERSONNEL EXPERIENCED IN SUCH WORK AND SHALL SCHEDULE THE WORK IN AN ORDERLY MANNER SO AS NOT TO IMPEDE PROGRESS OF THE PROJECT. B. BASIC MATERIALS AND METHODS 1. ALL ELECTRICAL WORK SHALL CONFORM TO THE EDITION OF THE NEC ACCEPTED BY THE LOCAL JURISDICTION AND TO THE APPLICABLE LOCAL CODES AND REGULATIONS. 2. ARRANGE CONDUIT, WIRING, EQUIPMENT, AND OTHER WORK GENERALLY AS SHOWN, PROVIDING PROPER CLEARANCES AND ACCESS. CAREFULLY EXAMINE ALL CONTRACT DRAWINGS AND FIT THE WORK IN EACH LOCATION WITHOUT SUBSTANTIAL ALTERATION. WHERE DEPARTURES ARE PROPOSED BECAUSE OF FIELD CONDITIONS OR OTHER CAUSES, PREPARE AND SUBMIT DETAILED DRAWINGS FOR ACCEPTANCE. 3. THE CONTRACT DRAWINGS ARE GENERALLY DIAGRAMMATIC AND ALL OFFSETS, BENDS, FITTINGS AND ACCESSORIES ARE NOT NECESSARILY SHOWN. PROVIDE ALL SUCH ITEMS AS MAY BE REQUIRED TO FIT THE WORK TO THE CONDITIONS. 4. SEAL AROUND CONDUITS AND AROUND CONDUCTORS WITHIN CONDUITS ENTERING THE MODULAR CABINETS WHERE PENETRATION OCCURS WITH A SILICONE SEALANT TO PREVENT MOISTURE PENETRATION INTO BUILDING. C. CONDUCTORS AND CONNECTORS 1. UNLESS NOTED OTHERWISE, ALL CONDUCTORS SHALL BE COPPER, MINIMUM SIZE #12 AWG, WITH THERMOPLASTIC INSULATION CONFORMING TO NEMA WC5 OR CROSS -LINKED POLYETHYLENE INSULATION CONFORMING TO NEMA WC7. (TYPES THHN). INSULATION SHALL BE RATED FOR 90 DEG. CONDUCTORS SHALL BE COLOR CODED IN ACCORDANCE WITH NEC. 2. CONDUCTOR LENGTHS SHALL BE CONTINUOUS FROM TERMINATION TO TERMINATION WITHOUT SPLICES. SPLICES ARE NOT ACCEPTABLE. IF SPLICES ARE UNAVOIDABLE PRIOR APPROVAL FROM THE ENGINEER MUST BE OBTAINED. D. GROUNDING 1. ALL LIGHTNING PROTECTION GROUNDING OF THE ELECTRICAL EQUIPMENT SHALL BE CARRIED OUT IN ACCORDANCE WITH THE CURRENT NFPA STANDARDS. 2. ALL GROUND LUG AND COMPRESSION CONNECTIONS SHALL BE COATED WITH ANTI -OXIDANT AGENT, SUCH AS NO-OX, NOALOX, PENETROX OR KOPRSHIELD. 3. ALL EXTERIOR GROUNDING CONDUCTORS INCLUDING EXTERIOR GROUND RING SHALL BE #2 AWG SOLID BARE TINNED COPPER. MAKE ALL GROUND CONNECTIONS AS SHORT AND DIRECT AS POSSIBLE. AVOID SHARP BENDS. THE RADIUS OF ANY BEND SHALL NOT BE LESS THAN 8" AND THE ANGLE OF ANY BEND SHALL NOT EXCEED 90% GROUNDING CONDUCTORS SHALL BE ROUTED DOWNWARD TOWARD THE BURIED GROUND RING. 4. REPAIR ALL GALVANIZED SURFACES THAT HAVE BEEN DAMAGED BY THERMO-WELDING WITH ERICO T-319 GALVANIZING BAR. 5. ALL EXTERNAL GROUND CONNECTIONS SHALL BE EXOTHERMICALLY WELDED. ALL EXOTHERMIC WELDS TO EXTERIOR GROUND RING SHALL BE THE PARALLEL TYPE, EXCEPT FOR THE GROUND RODS WHICH ARE TEE EXOTHERMIC WELDS. REPAIR ALL GALVANIZED SURFACES THAT HAVE BEEN DAMAGED BY EXOTHERMIC WELDING. USE SPRAY GALVANIZER SUCH AS HOLUB LECTROSOL #15-501. 1. CONTRACTOR AND SUBCONTRACTORS SHALL VERIFY ALL UTILITY SERVICE CONNECTION LOCATIONS PRIOR TO SUBMITTING BID AND PROCEEDING WITH WORK. IT IS RECOMMENDED THAT THE CONTRACTOR VISIT THE SITE AND VERIFY ALL DIMENSIONS AND NOTES BEFORE SUBMITTING BID AND PROCEEDING WITH WORK. 2. SOIL AT THIS SITE IS UNDISTURBED ROCK AND SAND ADEQUATE OF SUPPORTING THE DESIGN LOAD OF 2000 P.S.F. IF OTHER CONDITIONS ARE ENCOUNTERED, NOTIFY MORRISON HERSHFIELD BEFORE PROCEEDING WITH WORK. THIS VALUE IS CONSIDERED SAFE WITH RESPECT TO ACTUAL FAILURE OF THE SUPPORTING GROUND, BUT DOES NOT NECESSARILY ENSURE THE PREVENTION OF EXCESSIVE FOUNDATION MOVEMENTS. 3. IN ORDER TO AVOID ANY CONFLICTS, CONTRACTOR SHALL COORDINATE ALL HIS PRACTICAL TRADES. 4. THE POWER CABINET MUST BE CLEAR OF FLAMMABLE MATERIAL WITHIN 12 INCHES OF THE CABINET, INCLUDING ABOVE THE CABINET. 5. THE POWER CABINET MUST BE MOUNTED ON THE FOUNDATION TO ALLOW WATER TO DRAIN FROM THE DRAIN OUTLET AND AWAY FROM THE CABINET. 6. TO ENSURE SERVICEABLE ABILITY, THE DOORS OF CABINETS WILL REQUIRE AN OPENING RADIUS OF 36 INCHES OF CLEARANCE FROM THE CLOSED POSITION TO THE OPEN POSITION. SITE GENERAL NOTES 1. RESTORE EXISTING ASPHALT AND/OR CONCRETE COMPOUND TO IT'S ORIGINAL CONDITION. 2. CONTRACTOR SHALL DETECT AND MARK ANY UNDERGROUND LINES, PIPING, PRIOR TO START OF EXCAVATION. PROJECT INFORMATION 1. THIS IS AN UNMANNED AND RESTRICTED ACCESS EQUIPMENT AND WILL BE USED FOR THE TRANSMISSION OF RADIO SIGNALS FOR THE PURPOSE OF PROVIDING PUBLIC CELLULAR SERVICE. 2. THIS FACILITY WILL CONSUME NO UNRECOVERABLE ENERGY. 3. NO POTABLE WATER SUPPLY IS TO BE PROVIDED AT THIS LOCATION. 4. NO WASTE WATER WILL BE GENERATED AT THIS LOCATION. 5. NO SOLID WASTE WILL BE GENERATED AT THIS LOCATION. 6. T-MOBILE MAINTENANCE CREW (TYPICALLY ONE PERSON) WILL MAKE AN AVERAGE OF ONE TRIP PER MONTH AT ONE HOUR PER VISIT. IMPORTANT NOTICE THE EXISTING CONDITIONS REPRESENTED HEREIN ARE BASED ON VISUAL OBSERVATIONS AND INFORMATION PROVIDED BY OTHERS. MORRISON HERSHFIELD CORPORATION CANNOT GUARANTEE THE CORRECTNESS NOR COMPLETENESS OF THE EXISTING CONDITIONS SHOWN AND ASSUMES NO RESPONSIBILITY THEREOF. CONTRACTOR AND HIS SUB -CONTRACTORS SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS AS REQUIRED FOR PROPER EXECUTION OF PROJECT. REPORT ANY CONFLICTS OR DISCREPANCIES TO THE CONSULTANT PRIOR TO CONSTRUCTION. T 1VMo_a1 k 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA .;- CONSUL T.NG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W Ww.morrlsonheirshfielcl.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 SOX REVIEW BA 0 02/22/21 10096 FINAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: EDMONDS WAY/PUD/ BERSCHURE T-MOBILE SITE I.D. SE01632A SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 SHEET NAME: R (' I�/ GENERA�IQGTES May 05 202 SHEET NUMBER: DEPARTMENT T-2 C NOTE: THIS IS NOT A SURVEY. ALL INFORMATION AND TRUE NORTH HAVE BEEN OBTAINED FROM EXISTING DRAWINGS AND JURISDICTIONAL CIS INFORMATION AND ARE APPROXIMATE. TAX PARCEL: 27033600118400 EXISTING DRIVEWAY (TYP) T—MOBILE INSTALLATION AT TOP OF POLE EXISTING t60'—O" STEEL UTILITY POLE EXISTING SHRUB (TYP), TAX PARCEL: 00391400001401 I EXISTING T—MOBILE I F I FENCED EQUIPMENT AREA I AT GROUND LEVEL ♦ TAX PARCEL:. ♦ _ _ 00391400001602 TAX PARCEL: 003914000111601 I 24"x36" SCALE: 1" = 20'-0" 11"x17" SCALE: 1" = 40'-0" 20 10 0 0. LEGAL DESCRIPTION: ABBREVIATED PER ASSESSOR RECORDS EDMONDS HI WAY TRACTS BILK 000 D-00 LOT 1 LESS S/HWY TGW EDT —LOTS 2 & 3 EXC S 65FT OF SO LOTS 2 & 3 & LESS S/HWY (PER CITY EDM LOT AGGREGATION REC AF NO 9704210890) TAX PARCEL: / 27033600107500-- TMO N —� 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA .;- CONSUL T.NG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 www. morrison h ershfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 90x REVIEW BA 0 02/22/21 100x FINAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY ENGINEERING DIVISION SITE NAME: APPROVED EDMONDS WAY/PUD/ 95/08/2021 BERSCHURE T—MOBILE SITE I.D. RECEIVED SE01632A May 05 2021 SITE ADDRESS: 9726 EDMONDS WAY CITY OF EDMONDS EDMONDS, WA98020 DEVELOPMENT SERVICES DEPARTMENT SHEET NAME: 0 SITE PLAN 0 SHEET NUMBER: Know what's below. Call before you dig. A-1 SITE PLAN 11 FACE OF CURB E D M 0 N D S W A 1 EXISTING SHRUB 24"x36" SCALE: 3/16" = 1'-0" 11"07" SCALE: 3/32" = 1'-0" 4' 2' 0" 4 EXISTING HANDHOLE (TYP) T—MOBILE ANTENNAS AND 1 ANCILLARY EQUIPMENT ON POLE RF-1 W O RIGHT—OF—WAY _ EXISTING f60'—O" STEEL UTILITY POLE I W W II W N' W yIII�, W N' y V 11 W W EXISTING T—MOBILE FEEDLINES [(8) 7/8" COAX & (1) HCS 1.0 CABLE] WITHIN UNDERGROUND CONDUIT, VERIFY ROUTE �✓ w REMOVE ALL FEEDLINES EXISTING PARKING LOT � N' `7' I N' PROPOSED T—MOBILE FEEDLINES [(2) HCS 2.01 ROUTED WITHIN EXISTING CONDUIT EQUIPMENT AREA NOTES: _ 1. CONTRACTOR IS RESPONSIBLE FOR COMPLYING ®_ WITH ALL FEDERAL, STATE AND LOCAL CODES ® 0 0 ee - 2. CONTRACTOR IS RESPONSIBLE FOR PULLING ALL ®®y REQUIRED PERMITS AND ARRANGING FOR ALL ' INSPECTIONS AND OBTAINING ALL APPROVALS 3. CONTRACTOR SHALL LOCATE AND MARK ANY UNDERGROUND UTILITIES PRIOR TO EXCAVATION 19807 NORTH CREEK PKWYN BOTHELL, WA 98011 1 N RYKA#CDNSU' T.NG NOTES: PLAN INFORMATION CONTAINED HEREIN IS TAKEN FROM THE DOCUMENTS PROVIDED BY CLIENT. NEITHER WARRANTY NOR GUARANTEE IS GIVEN BY THE ARCHITECT NOR MORRISON HERSHFIELD CORPORATION TO THE ACCURACY NOR THE COMPLETENESS OF THE COPIED COMPOUND PLAN INFROMATION. ENLARGED SITE PLAN 11 PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 ww W.morrlsonheirshfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 90% REVIEW BA 0 02/22/21 100% FINAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY NIL INAMIL: EDMONDS WAY/PUD/ BERSCHURE T—MOBILE SITE I.D. S E01632A SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 SHEET NAME: ENLARKE-CLu'llAI PLpOqNy 05 202 SHEET NUMBER: DEPARTMENT A-1.1 EXISTING T—MOBILE ACCESS GATE EXISTING IRRIGATION CONTROL VALVE EXISTING WOOD FENCE EXISTING T—MOBILE LEC---_ ROUTER TO BE RELOCATED TO AAV CUBE* EXISTING T—MOBILE INTERNAL EQUIPMENT TO BE REMOVED; EXISTING FSMF IS DOCUMENTED AS VERSION 102 & NOT SUITABLE FOR RE —USE EXISTING T—MOBILE TECH LIGHT REMOVED G T—MOBILE SURGE ESSOR (ABOVE) TO BE REMOVED E REPLACED/UPGRADED• j POWER I o \ \\ CABINET \ TO BE \ REMOVED I I I I > ULTRASITE TO BE R IMOVEI I FUCA �\ TO BE REMOVED J \\`jhIIL— J 0 EXISTING T—MOBILE GPS ANTENNAI J a I (1) TO BE RELOCATED, (2) TO BE REMOVED I EXISTING CRAWL SPACE - ACCESS HATCH I I EXISTING CONCRETE E I PAD I EX STING B ILDING 24"x36" SCALE: 1/2" = V-0" 11"x17" SCALE: 1/4" = V—O" 2 1' 0" 2 EXISTING BUILDING BATTERY NOTE: NOTES: (4) STRINGS OF (4) 116 CELLS TOTAL) OF VALVE REGULATED 1. CONTRACTOR IS RESPONSIBLE FOR COMPLYING LEAD ACID BATTERIES (VRLA) WITH IMMOBILIZED ELECTROLYTE WITH ALL FEDERAL, STATE AND LOCAL CODES TECHNOLOGY AT 2.34 GALLONS PER CELL. TOTAL ELECTROLYTE 2. CONTRACTOR IS RESPONSIBLE FOR PULLING ALL VOLUME IS 37.44 GALLONS. AS THE TOTAL ELECTROLYTE REQUIRED PERMITS AND ARRANGING FOR ALL VOLUME DOES NOT EXCEED 50 GALLONS, COMPLIANCE WITH INSPECTIONS AND OBTAINING ALL APPROVALS INTERNATIONAL FIRE CODE SECTION 608 IS NOT REQUIRED. 3. CONTRACTOR SHALL LOCATE AND MARK ANY N UNDERGROUND UTILITIES PRIOR TO EXCAVATION POWER UPGRADE NOTE: EXISTING 100A AC SERVICE IS TO BE UPGRADED TO 200A PER SEPARATE ELECTRICAL SERVICE UPGRADE SCOPE OF WORK/DESIGN, UNDER SEPARATE ELECTRICAL PERMIT AS REQUIRED, TO BE INCLUDED IN NTP SEE POWER SURVEY/UCR *TO BE REPLACED/UPGRADE PER POWER SURVEY/UCR BY OTHERS, UNDER SEPARATE COVER, TO BE INCLUDED IN NTP & UNDER SEPARATE ELECTRICAL PERMIT IF REQUIRED EXISTING T—MOBILE TELCO BOX (TYP OF 2) TO BE REMOVED EXISTING T-MOBILE SERVICE PANEL TO BE REPLACED/UPGRADED* EXISTING T-MOBILE GEN PLUG (BELOW) TO BE REMOVED EXISTING T—MOBILE CABLE SUPPORT FRAME TO REMAIN EXISTING CONDUIT STUB —UP (TYP OF 4) TO REMAIN EXISTING T—MOBILE (8) 7/8" COAX TO BE REMOVED EXISTING T—MOBILE EQUIPMENT MOUNTED TO WALL (TYP) TO REMAIN EXISTING T-MOBILE COVE TO BE REMOVED EXISTING T—MOBILE EQUIPMENT H—FRAME TO REMAIN EXISTING T—MOBILE ACCESS GATE EXISTING IRRIGATION CONTROL VALVE I EXISTING WOOD FENCE HPL3 SSC WITH NEW CSR IXRe ROUTER, (1) NEW FSMF, (2) AMA WITH BASEBAND MODULES PER REDS PROPOSED BATTERY CABINET: SEE BATTERY NOTE EXISTING EQUIPMENT PLAN 12 11 x17" SCALE: 1/46" SCALE: " = V-0" 2' 1, 0112' ** SEE UTILITY SCOPE OF WORK & POWER -PROPOSED CAM LOC SURVEY/UCR BY OTHERS, UNDER SEPARATE MOUNTED TO WOOD FENCE COVER, TO BE INCLUDED IN NTP & UNDER SEPARATE ELECTRICAL PERMIT IF REQUIRED **UPGRADED T—MOBILE METER **RELOCATED LEC ROUTER WITHIN MV CUBE \\ **PROPOSED AAV CUBE \ ON EXISTING UNISTRUT A-4 \ PROPOSED LED TECH LIGHT ( #RAB X43 OR APPROVED EQUAL EXISTING CONCRETE PAD EXISTING CRAWL SPACE ACCESS HATCH TO REMAIN I I 1 HPL3 600A ' DC CABINET \ 1 A-5 I HPL3 BATTERY CABINET I E STING B LDING 3' CLEAR **PROPOSED EMERSON AC PANEL WITH CAM LOC GENERATOR PLUG EXISTING CONDUIT STUB —UP (TYP OF 4) EXISTING T—MOBILE CABLE SUPPORT FRAME EXISTING T—MOBILE EQUIPMENT MOUNTED TO WALL (TYP) EXISTING CRAWL SPACE ACCESS HATCH TO REMAIN PROPOSED T—MOBILE HCS 2.0 JUNCTION BOXES MOUNTED TO EXISTING H—FRAME (TYP OR 2) EXISTING T—MOBILE EQUIPMENT H—FRAME RELOCATED T—MOBILE GPS ANTENNA Hill `PROPOSED 24" WIDE ICE BRIDGE 7'f TALL AS REQUIRED (MINIMIZE HEIGHT) PROPOSED 12" GRIPSTRUT ON 2"0 POST PROPOSED OVERHEAD FIBER PATH FROM COVPs TO HPL3 EXISTING BUILDING T mo_a s N 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA .;- CONSUL T.NG NOTES: PLAN INFORMATION CONTAINED HEREIN IS TAKEN FROM THE DOCUMENTS PROVIDED BY CLIENT. NEITHER WARRANTY NOR GUARANTEE IS GIVEN BY THE ARCHITECT NOR MORRISON HERSHFIELD CORPORATION TO THE ACCURACY NOR THE COMPLETENESS OF THE COPIED COMPOUND PLAN INFROMATION. PROPOSED EQUIPMENT PLAN 11 PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 www. morrison h ershfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 90x REVIEW SA 0 02/22/21 100x FINAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: EDMONDS WAY/PUD/ BERSCHURE T—MOBILE SITE I.D. SE01632A SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 SHEET NAME: EQ6WE4MIVE4 PLAH§ 05 202 11 SHEET NUMBER: DEPARTMENT A-1.2 TIP HEIGHT OF EXISTING T-MOBILE ANTENNAS TIP HEIGHT OF T-MOBILE ANTENNAS t74'-6" AGL N n EXISTING T-MOBILE PANEL ANTENNA }7q'_6" AGL (TYP OF 2, 1 PER SECTOR) II II TO BE REMOVED /L RAD CENTER OF EXISTING T-MOBILE ANTENNAS II t72'-0" AGL II BRAD CENTER OF PROPOSED T-MOBILE ANTENNAS f70 -6 AGL EXISTING T-MOBILE DIPLEXER —EXISTING T-MOBILE TMA'S (TYP OF 8, 4 PER SECTOR)-1 II MOUNTED BEHIND ANTENNAS TO BE REMOVED - OF TO BE REMOVED TO EXISTING T-MOBILE FXFB RRU -- == EXISTING T-MOBILE FRIG RRU (TYP OF 2) (TYP OF 2, 1 PER SECTOR) TO BE REMOVED TO BE REMOVED 2HAT F T-MOBILE ANTENNAS LO f6P 1H-E7IG EXING POLE POLE tP '-O0F " f'-O0F " AGING EXISTING T-MOBILE COVP TO BE REMOVED RAD CENTER OF PROPOSED T-MOBILE ANTENNAS t60'-0" AGL EXISTING T-MOBILE ANTENNA MOUNT TO REMAIN STEELTIUTILITY POLE I EXISTING TY POLE STEEL UTILITY POLE EXISTING T-MOBILE FEEDLINES PROPOSED T-MOBILE FEEDLINES [(8) 7/8" COAX & (1) HCS 1.0 CABLE] [(2) HCS 2.01 ROUTED WITHIN POLE ROUTED WITHIN POLE REMOVE ALL FEEDLINES EXISTING TRANSFORMER EXISTING OVERHEAD CABLE (TYP) EXISTING CONDUIT EXISTING T-MOBILE (TYP OF 4) EQUIPMENT AREA _ EXISTING BUILDING EXISTING T-MOBILE METER (TYP) -LLLLLLLLLL _LLLL LLLLLH TO BE UPGRADED; SEE _LLLLLLLLLL _LL LLLLL LLLL EXISTING T-MOBILE POWER UPGRADE NOTES EQUIPMENT AREA LLLLLLLLLLLLLLLLLLLLLLLLL - LLLLLLLLLLLLLLLLLLLLLLLLLL - UPGRADED - LLLLLLLLLLLLLLLLLLLLLLLLLLL - T-MOBILE METER - - O - O h GRADE } GRADE ASSUMED 0'-0" � ASSUMED 0'-0" R PROPOSED T-MOBILE PANEL ANTENNA (TYP OF 2, 1 PER SECTOR) A-3 U PROPOSED T-MOBILE AHLOA RADIO 5 (TYP OF 2, 1 PER SECTOR) A-3 PROPOSED T-MOBILE AHFIG �(TYP OF 2, 1 PER SECTOR) RADIOe A-3 J PROPOSED T-MOBILE AEHC I 3 ANTENNA (MASSIVE-MIMO) R„ (TYP OF 2, 1 PER SECTOR) A-3 EXISTING T-MOBILE ANTENNA MOUNT NOTES: 1. INFORMATION CONTAINED HEREIN IS TAKEN FROM THE DOCUMENTS PROVIDED BY CLIENT. NEITHER WARRANTY NOR GUARANTEE IS GIVEN BY THE ARCHITECT NOR MORRISON HERSHFIELD CORPORATION TO THE ACCURACY NOR THE COMPLETENESS OF THE COPIED ELEVATION INFORMATION. 2. NO WORK SHALL COMMENCE WITHOUT THE APPROVED ANTENNA MOUNT STRUCTURAL ANALYSIS REPORT SIGNED AND SEALED BY A LICENSED PROFESSIONAL ENGINEER UNDER SEPARATE COVER. IF REQUIRED, THE CONTRACTOR SHALL MODIFY ANTENNA MOUNTS AS INDICATED IN THE ABOVE MENTIONED STRUCTURAL REPORT OR ASSOCIATED MODIFICATION DESIGN DRAWINGS. EXISTING TRANSFORMER EXISTING OVERHEAD CABLE (TYP) EXISTING CONDUIT (TYP OF 4) EXISTING BUILDING (TYP) ENGINEERING DIVISION APPROVED. 05/08/2021 T .Moi ll s 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA .;- CONSUL T.NG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 v .morrlsonhershfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 90x REVIEW BA 0 02/22/21 100x FINAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: EDMONDS WAY/PUD/ BERSCHURE T-MOBILE SITE I.D. SE01632A SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 SHEET NAME: R E c E I�[ TOWERFRQFfLES May 05 202 SHEET NUMBER: DEPARTMENT 2 C 24"x36" SCALE: 1/4" = 1'-O" 11"x17" SCALE: 1/8" = 1'-O" 4' 3' 2 1 0 4' EXISTING TOWER PROFILE 1 2 1 11�07" SALE: 1/8" = 4' 3' 2' 1' 0" 4 PROPOSED TOWER PROFILE 1 1 ANILNNA IILI BNACKLI (_A BY ANTE PIPE MOUNTING BRACKETS BY ANTENNA MFRM MOUNTING HARDWARE PROVIDED BY EQUIPMENT MFR MANUFACTURER: NOKIA MODEL: AHLOA RADIO WEIGHT: 83.8 LEIS DIMENSIONS (HxWxD): 22.1"x12.1%7.4" FREQUENCY: REFER TO RF DATA SHEET NOTE: MOUNT PER MANUFACTURER'S SPECIFICATIONS MANUFACTURER: NOKIA MODEL: AHFIG RADIO WEIGHT: 79.4 LBS DIMENSIONS "" " HXWxD : 27.6x 13.4x 5.6 ( ) e ®-- ee o k FREQUENCY: REFER TO RF DATA SHEET NOTE: 19807 NORTH CREEK PKWY N MOUNT PER MANUFACTURER'S SPECIFICATIONS BOTHELL, WA 98011 13.4" - m 1 RYKA 1 .;- CONSUL T.NG PANEL ANTENNA TOP TOP ISOMETRIC MOUNTING PIPE PIPE 7.4" \ ANCILLARY EQUIPMENT c N N N N N N FRONT SIDE NOTE: MOUNT UNIT PER MANUFACTURER'S RECOMMENDATIONS FRONT SIDE SCALE NTS TYP ANTENNA MOUNTING 7 SCALE: NTS 11 x17" TYP RADIO MOUNTING 6 SCALE: NTS 11 AHLOA 5 11 x17" Ste: NTS AHFIG 141 111"x17" SCALE: NTS SCALE: NTS x17" SCALE: NTS MANUFACTURER: NOKIA MODEL, NOKIA AIRSCALE MAA 64T64R 192AE 841 320W AEHC WEIGHT: 108 LBS (W/O MOUNTING BRACKETS) DIMENSIONS: 38.2" x 21.5" x 5.9" FREQUENCY: REFER TO RF DATA SHEET TOP 5.9" 2. FRONT SIDE N N rn 25.197" TOP N V m 25.197" FRONT MANUFACTURER: COMMSCOPE MODEL: FFVV-65C-R3-V1 WEIGHT: 124.561 LBS (WITHOUT MOUNTING KIT) DIMENSIONS (LxWxD): 95.945" x 25.197" x 9.252" FREQUENCY: REFER TO RF DATA SHEET 9.252" SIDE PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 v .morrlsonhershfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 90x REVIEW BA 0 02/22/21 100x FINAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: EDMONDS WAY/PUD/ BERSCHURE T-MOBILE SITE I.D. SE01632A SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 SHEET NAME: CON, Ed DETAIL805 202 SHEET NUMBER: DEPARTMENT A-3 C 11"x17" SCALE: NTS AEHC ACTIVE ANTENNA/RADIO NTS AEHC ACTIVE ANTENNA/RAD10133 11� 17" SCALE, NTS ANTENNA SPECIFICATIONS12 1 11"x17�� SCALE: NTSSCALE: NTS ANTENNA SPECIFICATIONS12 1 11"x17�� SCALE: NTS NOT USED 111"x17 SCALE: NTS NOT USED1"x17" NTS NOT USED1 GALV. BOX FRAME PART OF CABINET OR PLINTH NOTE: EQUIPMENT CABINET(S) TO BE MECHANICALLY ATTACHED PER MANUFACTURER'S RECOMMENDATIONS (4) 5/8"0 HILTI KB—TZ EXPANSION BOLTS (4-1/8" EMBED) INTO CONC CONC SLAB SCALE: NTS 11 x137" SCALE: WS CABINET ATTACHMENT 171 RRIJ END POWER CORD DLG FLEX CONNECTORS NV/ BOOT XX CABLE LENGTH PENDANT END HOLC CONNECTOR -' MANUFACTURER: NWS MODEL: — WEIGHT: 1.61 LB/FT DIMENSIONS: 10.2"x 16.0"x3.2" 0 ro 10.2" MOUNTING KIT BY MFR PIPE 111"x17" SCALE: NTS NOT USED 161 11 SCALE: NTS 17" SCALE: NTS HCS 2.0 JUMPER CABLE 15 11SCALE: NTS 1�07" SCALE: N S HCS 2.0 PENDANT 141 0 0 N 22.9" PLAN VIEW 3.0" FRONT VIEW HEAT EXCHANGER ANGER HEAT XCHANGER MANUFACTURER: CHARLES MODEL: CUBE RL1003AB—A WEIGHT: 260 LBS DIMENSIONS: 22.9"x 2 6.3"x 2 0. O" INSTALL PER MFR SPECIFICATIONS 20.0" RIGHT VIEW MANUFACTURER: RAYCAP MODEL' — WEIGHT: 21.9 LBS DIMENSIONS: 14.0"x 16.0"x8.0" NOTE: MOUNTING KIT BY MFR 14.0" 8.0" o FRONT VIEW RIGHT VIEW T mm��s 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA .;- CONSU' T.NG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 v .morrlsonhemhfield.com MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 SOX REVIEW SA 0 02/22/21 100x FINAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: EDMONDS WAY/PUD/ BERSCHURE T—MOBILE SITE I.D. SE01632A SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 SHEET NAME: CONII DETAIL805 202 SHEET NUMBER: DEPARTMENT A-4 C 24"x36" SCALE: NTS 11"07" SCALE: NTS AAV CUBE 1 3 111 24"%36p SCALE: NTS NOT USED 12 111 x17" SCALE: NTS H24:0CS 2.0 JUNCTION BOX 11 MANUFACTURER: PURCELL SYSTEMS INC MODEL: HPL3600A DC CABINET WEIGHT: 430 LBS (WITHOUT EQUIPMENT) DIMENSIONS : 30.0"x4 8.0"x 72.0" NOTE: • ADDITIONAL KNOCKOUTS MAY BE REQUIRED AND CAN BE DRILLED ON SITE AS NECESSARY. FOR CABINETS STARTING AT 501 THERE WILL BE A TOTAL OF (8) KNOCKOUTS (2) HORIZONTAL ROWS OF (4) RACK ASSIGNMENT RACK RU SLOT DESCRIPTION a 0 15 3RD AIRSCALE 14 13 12 FIBER MUX 11 10 2ND AIRSCALE 9 8 7 FIBER MUX 6 5 1ST AIRSCALE 4 3 2 FIBER MUX 1 RECTIFIER SHELF 0 m 16 AAV 15 CSR 14 13 4TH AIRSCALE 12 11 10 FIBER MUX 9 3RD LEGACY BBU 8 7 6 2ND LEGACY BBU 5 4 3 1ST LEGACY BBU 2 1 N N r ISO VIEW FRONT VIEW 30" 4X .875 0 HOLES FOR HPL3 AND EXPANSION CABINET 2—STRING BATTERY RACK MOUNTING POINTS 0o 00 o 0 O C O O 4X .875 0 HOLES FOR HPL3 4—STRING BATTERY RACK MOUNTING POINT SHIPPING HOOKS TO BE REMOVED AFTER CABINET INSTALL CORRECT KNOCKOUT TOOL REQUIRED FOR PUNCHING KNOCKOUTS; DO NOT DRILL KNOCKOUTS THROUGH SKU# 34038 PURCELL 2" PLINTH (OPTIONAL) FIBER ROUTE OPTION 1:— IT IS STRONGLY RECOMMENDED TO USE THESE (4) KNOCKOUTS TO & FROM COVP WITH WATER —TIGHT LB OR GROMMET N SKU# 34038 PURCELL 2" PLINTH PLAN VIEW PLAN VIEW $„ 32„ 8„ L i 00 000 00 000 O 01 oo 8g 88 88 0 0 0 RIGHT VIEW (6) KNOCKOUTS LOCATED INCONVENIENTLY FROM INTERNAL AIRSCALE EQUIPMENT & ARE NOT FEASIBLE. SEE FIBER ROUTE OPTION 1. KNOCKOUT FOR ETHERNET FOR ALARMS KNOCKOUTS FOR BATTERY WIRES 4X .75 0 HOLES FOR HPL3 AND EXPANSION CABINET CORNER MOUNTING POINTS SKU# 34038 PURCELL 2" PLINTH SIDE VIEW (4x) 5/8"0 FOR BATTERY MOUNTING (4x) 5/8"0 FOR CABINET ANCHORAGE •• •0 BACK VIEW ALL DC POWER CABLES (BLUE) TO BE ROUTED AT THE LEFT SIDE OF THE CABINET 28" 2 3/4 22 1/2" MOUNTING FOOTPRINT AIRS, BASEE FIBER ROUTE OPTION 2: REAR KNOCKOUTS CAN BE UTILIZED FOR BOTTOM FIBER ROUTING FROM COVP TO AIRSCALE IF OPTION 1 IS UNAVAILABLE. ALPHA (48 BREAKER (8) 2" KNOCKOUTS INTENDED FOR POWER, TELCO, & BOTTOM FIBERS TO COVP; ALL INCOMING CABLING TO BE IN RIGID OR FLEXIBLE CONDUIT WITH AN LB ANY OF THE BOTTOM KNOCKOUTS CAN BE USED FOR THE AC POWER FEED CSR F INTERNAL ROUTING FRONT VIEW (OPEN) FIBER KNOCKOUT FIBER CABLES (YELLOW) 19" RACK ADAPTER ALL FIBER CABLES (YELLOW) TO BE ROUTED AT THE RIGHT SIDE OF THE CABINET FIBER MUX/ DEMUX T Mok.P__% 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA .;- CONSU' T.NG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W Ww.morrlsonheirshfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 90x REVIEW BA 0 02/22/21 100x FINAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY RECTIFIERS (10 SITE NAME: POSITIONS) EDMONDS WAY/PUD/ BERSCHURE T—MOBILE SITE I.D. SE01632A AIRSCALE BASEBAND SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 LEGACY BASEBAND SHEET NAME: ik CON �FV DETAIL805 202 SHEET NUMBER: DEPARTMENT A-5 C J 24"x36" SCALE: NTS 11"07" SCALE: NTS PURCELL HPL3 600A DC POWER CABINET SPECIFICATIONS 1 1 JAUFA TURER: PUR ELL V TEM IN EL: HPL3 LARGE BATTERY CABINET GHT:350LBS (WITHOUT EQUIPMENT) N S I O N S: 30.0"x31.6"x60.4" NOTE: • WIRES RUN THROUGH PROVIDED KNOCKOUT. FOLLOW PROPER INSTALLATION OF GASKET BEFORE MATING THE 2 CABINETS 4X .875 0 HOLES FOR HPL3 AND EXPANSION CABINET 2—STRING BATTERY RACK MOUNTING POINTS 4X .875 0 HOLES FOR HPL3 4—STRING BATTERY RACK MOUNTING POINT SKU# 34038 PURCELL 2" PLINTH PLAN VIEW 4X .75 0 HOLES FOR HPL3 AND EXPANSION CABINET CORNER MOUNTING POINTS SKU# 34038 PURCELL 2" PLINTH SIDE VIEW O m N KNOCKOUT F ETHERNET F ALAS KNOCKOUTS FOR BATTERY WIRES SHIPPING HOOKS TO BE REMOVED AFTER CABINET INSTALL ORRECT KNOCKOUT TOOL EQUIRED FOR PUNCHING NOCKOUTS. DO NOT DRILL NOCKOUTS THROUGH SKU# 34038 PURCELL 2" PLINTH (OPTIONAL) BATTERY BRACKETS BATTERY VIBRATION MOUNTS 30" T .MOB, s FOR CABINET 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA .;- CONSU' T.NG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W Ww.morrlsonhemhfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 90x REVIEW BA 0 02/22/21 100x FINAL LW USED FOR CONSTRUCTION BY DESIGN PROFESSIONAL ffTA'ITIEDPPROVED BY MUNICIPALITY SITE NAME: EDMONDS WAY/PUD/ BERSCHURE T—MOBILE SITE I.D. BATTERY SE01632A ELVES, UP TO DAH SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 SHEET NAME: CON,rdIW DETAILL805 202 SHEET NUMBER: DEPARTMENT A-6 C 24"x36" SCALE: NTS 11"x17" SCALE: NTS PURCELL HPL3 LARGE BATTERY CABINET SPECIFICATIONS 1 1 MANUFACTURER: NOKIA MODEL: ASIB MODULE DIMENSIONS: 8.6"04.2%1.7" WEIGHT: 6.4 LBS � - ww ,l PROPOSED ASIB LOCATED WITHIN AMIA RACK MANUFACTURER: NOKIA MODEL: ABIA MODULE DIMENSIONS: 8.6"x14.2"x1.1 " WEIGHT: 4.6 LBS re iiiiii i iC'-G- �w .. w mow, w w, Pew s. �"��• til I w!w ` PROPOSED ABIA LOCATED WITHIN AMIA RACK MANUFACTURER: NOKIA MODEL: ABIL MODULE DIMENSIONS: 8.6"04.2"0.1 " WEIGHT: 4.4 LBS SFP28 S-RF1 S-RF2 000000000000000000000 Do 0o go 0 0. 000o0000oo00o0o00000o0000 00 00000 00 0 0000000$00000000 0 0 00 0 S-RF1 S-RF2 QSFP28 I O PROPOSED ABIL LOCATED WITHIN AMIA RACK I?"x7" 24"x36" SCALE: NITS 24"x36 SCALE: NITS 1 1SCALE: NTS AS I B161 11 "x17" SCALE: NTS ABIA 5 11 "x17" SCALE: NITS ABIL 141 MANUFACTURER: NOKIA MODEL: ABIC MODULE DIMENSIONS: 8.6"x14.2"x1.7" WEIGHT: 5.8 LBS RF2 RF4 RF6 RF8 RF1 RF3 RF5 RF7 RF9 MANUFACTURER: NOKIA MODEL: ASIK MODULE DIMENSIONS: 8.6"x14.2"x1., WEIGHT: 6.6 LBS •••••�••:••� • • • •Z•IQ•I•UI•U;� 1111 � �T• � � �1 � � 11 � � � � � •'• � � . _'! O iii » PROPOSED ASK LOCATED WITHIN AMIA RACK T Mo all IQ 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA .;- CONSUL T.NG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W Ww.morrlsonheirshfielcl.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 90x REVIEW BA 0 02/22/21 100x FINAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: EDMONDS WAY/PUD/ BERSCHURE T—MOBILE SITE I.D. SE01632A SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 SHEET NAME DETAIL805 202 SHEET NUMBER: DEPARTMENT 7 24"x36" SCALE: NTS 11"x17" SCALE: NTS ABI 3 24"x36" SCALE: NTS l� 11"x17" SCALE: NTS NOT USED 1 2 1 11"x17= SCALE: Nn ASK 1 1 MANUFACTURER: NOKIA MODEL: AMIA DIMENSIONS: 5.1 "X1 5.7"X1 7.6" WEIGHT: 11.2 LBS MANUFACTURER: NOKIA MODEL: FSMF MODULE 176" DIMENSIONS: 5.2"x17.6"x16.5" WEIGHT: 25.3 LBS NOTE: FSMF SHALL BE PLACED WITHIN RADIO CABINET PER T—MOBILE fD REQUIREMENTS N SIDE TOP INN �. a 11.�1�11.1�11.11�I:I�IL�I,i1�.� �LI ILI�I�.I�IL�LI'�a �i�j� ��:I U.I �I:I 1.1 I�.I �I.I ILI Uil ILIU.I i II Illl�a 111 if,_Illall:I N OPTIONAL POWER DISTRIBUTION OPTIONAL CAPACITY OPTIONAL TRANSPORT SUB —MODULE EXTENSION SUB —MODULE SUB —MODULE MANUFACTURER: NOKIA MODEL: IXR-E MODULE DIMENSIONS: 17.25"x 10.0"x 1 .75" WEIGHT: TBD MMww1WW 9iw W*7W www 11=:17" SCALE: NITS AMIA 16 " SCALE: NITS 111 x17" SCALE: NITS FSMF 15 111SCALE: NITS x17" SCALE: NITS IXRx36" SCALE: NITS -E 14 T Mobile 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 RYKCDNSULTING PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 www. morrison h ershfield.00m MH PROJECT NUMBER: 202119200 REV. DATE I ISSUED FOR BY A 01/21/21 90% REVIEW BA 0 02/22/21 100% flNAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: EDMONDS WAY/PUD/ BERSCHURE T—MOBILE SITE I.D. S E01632A SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 SHEET NAME: CON rdw DETAILS05 202 SHEET NUMBER: DEPARTMENT All "x" SCALE: NITS NOT USED 1 3 1 11"x24 �17SCALE: NITS " SCALE: NTS 11 x1717" SCALE: NITS SCALE: NITS NOT USED 1 2 1 11".17"24" SCALE: NITS NOT USED 11 EXISTING ANTENNA AND COAX SCHEDULE REDS ANCHOR VERSION 4, DATED 01/15/2 SECTOR ALPHA AZIMUTH RAD CENTER NUMBER OF VENDOR MODEL NUMBER OF FEEDERS FEEDER TYPE FEEDERANTENNAS LENGTH ADDITIONAL EQUIPMENT (1) FRIG Al 60' 72'-0" 1 ANDREW TMZXXX-6516-A3M (HEX) 4 7/8" 135't (2) FXFB (2) DUAL TMA (4) DIPLEXERS SECTOR BETA AZIMUTH RAD CENTER NUMBER OF VENDOR MODEL NUMBER OF FEEDER TYPE FEEDER ADDITIONAL EQUIPMENT ANTENNAS FEEDERS LENGTH (1) FRIG 4 7/8" 135'f (1) TWIN TMA B1 310' 72'-0" 1 ANDREW TMZXXX-6516-A3M (HEX) (4) DIPLEXERS 1 HCS 1.0 CABLE 175't (1) COVP EXISTING T-MOBILE FRIG RADIO (TYP OF 2, 1 PER SECTOR) TO BE REMOVED EXISTING T-MOBILE PANEL ANTENNA [ANDREW TMZXXX-6516-A3M (HEX)] q� 6� TO BE REMOVED 9 J EXISTING T-MOBILE TWIN TMA MOUNTED BEHIND ANTENNAS 81 / TO BE REMOVED Q�,P i " 1113 Al EXISTING T-MOBILE COVP (BELOW) TO BE REMOVED ` EXISTING T-MOBILE DIPLEXER EXISTING T-MOBILE PANEL ANTENNA MOUNTED (BELOW) [ANDREW TMZXXX-6516-A3M (HEX)] (TYP OF 8, 4 PER SECTOR) TO BE REMOVED TO BE REMOVED EXISTING T-MOBILE DUAL TMA's MOUNTED BEHIND ANTENNAS (TYP OF 2) TO BE REMOVED EXISTING t60'-O" STEEL UTILITY POLE EXISTING T-MOBILE FXFB RADIO (TYP OF 2) TO BE REMOVED EXISTING T-MOBILE ANTENNA MOUNT TO REMAIN RAD CENTER 72'-0" D21 3:48:16 PM PROPOSED ANTENNA AND COAX SCHEDULE REDS ANCHOR VERSION 4, DATED 01/15/2021 3:48:16 SECTOR ALPHA AZIMUTH RAD CENTER NUMBER OF ANTENNAS VENDOR MODEL NUMBER OF FEEDERS FEEDER TYPE FEEDER LENGTH ADDITIONAL EQUIPMENT Al 60' 70'-6" 1 COMMSCOPE FFW-65C-R3-V1 (OCTO) _ _ _ (1) AHFIG RADIO (1) AHLOA RADIO A2 60' 60'-0" 1 NOKIA AEHC ACTIVE ANTENNA SECTOR BETA AZIMUTH RAD CENTER NUMBER OF ANTENNAS VENDOR MODEL NUMBER OF FEEDERS FEEDER TYPE FEEDER LENGTH ADDITIONAL EQUIPMENT B1 310' 70'-6" 1 COMMSCOPE FFW-65C-R3-V1 (OCTO) 2 HCS 2.0 CABLES 175't (1) AHFIG RADIO (1) AHLOA RADIO B2 310' 1 60'-0" 1 NOKIA AEHC ACTIVE ANTENNA NOTES: 1. ALL PROPOSED EQUIPMENT IS LOW VOLTAGE, DC POWER 2. COORDINATE WITH CONSTRUCTION MANAGER FOR CURRENT REDS PRIOR TO CONSTRUCTION 3. CABLE LENGTH IS APPROXIMATE. CONTRACTOR TO FIELD VERIFY CABLE LENGTHS PRIOR TO ORDERING, FABRICATION, OR INSTALLATION OF CABLES. 4. NO WORK SHALL COMMENCE WITHOUT THE APPROVED ANTENNA MOUNT STRUCTURAL ANALYSIS REPORT (SIGNED AND SEALED) PROVIDED UNDER SEPARATE COVER. 2ePROPOSED T-MOBILE PANEL ANTENNA A-3 [COMMSCOPE FFW-65C-R3-Vl (OCTO)] 5 PROPOSED T-MOBILE AHLOA RAC BELOW ANTENI A-3 (TYP OF 2, 1 PER SECTO EXISTING ff STEEL UTILITY EXISTING T- ANTENNA MOUNT Q3 PROPOSED T A-3 AEHC i EXI STEE EXIS',,,., ANTENNA MOUNT RAD CENTER 70'-6" RAD CENTER 60'-0" Re 11 P� YPROPOSED T-MOBILE PANEL ANTENNA 2 [COMMSCOPE FFW-65C-R3-V1 (OCTO)] A-3 PROPOSED T-MOBILE AHFIG RADIO BELOW ANTENNA 4 (TYP OF 2, 1 PER SECTOR) A-3 PROPOSED T-MOBILE AEHC ANTENNA Ko P�Q 6d PM T .MOIL s 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA .;- CONSU' T.NG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 www. morrison h ershfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 90x REVIEW BA 0 02/22/21 100x FINAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: EDMONDS WAY/PUD/ BERSCHURE T-MOBILE SITE I.D. SE01632A SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 SHEET NAME CONFIGN,�LbPA2 SHEET NUMBER: DEPARTMENT RF-1 24"x36" SCALE: 3/4" = 1'-0" 11"07" SCALE: 3/8" = 1'-0" 1' 6" 0" 1 EXISTING ANTENNA LAYOUT 12 111�07" SCALE: 3/8" = -0" 1011. PROPOSED ANTENNA LAYOUT 11 Configuration 50091EZ_SR_U21 For 5G and LTE Airscale BB dimensioning refer to Finer Port matrices. (Alpha, Beta & Gamma) AEH LTE+SG Top Ground FDD - M idband 64 (L2100) - 20 MHz 41HQ lAd rjssrve Antenna B2 (L1900) - 20 MHz B25 (L1900) - 20 MHz List B66 (AWS3) - 5 MHz LZ1MWU SRAN - GSM PCS/UMTS AWS TDD - Band 41 U_ �1 L2.5-60MHz 1 , N2.5 - 100+80 MHz AH FIG AW5*PCS HCS2ba HM"0 (TowerTop �.Tcllwwop 1,152021 SE016VA Anchor 2021.01-15 (Configuration 56791][_5R For 5G and LTE Airscale GB dimensioning refer to Fiber Port matrices. (Alpha, Beta & Gamma) LB • MB FhI FDD - lowband P�%hw Anl!rntu B12 (L700)- 5 MHz B71 (L600) -10 MHz u" Lo B71 (N60C� - 10 MHz L21+AWS3 FDD - Midband B4 (L2100) - 20 MHz HIF B2 (L1900) - 20 MHz uia B25 (L1900) - 20 MHz *$G S/1 B66 (AWS3) •- 5MHz SRAN - GSM PCS/UMTS r ` AW5 TDD - Band 41 L2.5 - 60 MHz AHL.OA AHFIG N15-60MHz 700*600 1 AWS+PCS Top Grwnd HMA �.a TowMrrov I rorwfTap SRAN LTE + UMTS + GSM FSMF SRAN LTE + UMTS + GSM 5G Airscale GSMIUMTS FSMF PCS 5G Airscale GSM/UMTS PCS LTE FDDITOD Airscalei 4LTE FOC�ITDCJ Airscalel W11X bit vat q T .M0_a s 19807 NORTH CREEK PKWV N BOTHELL, WA 98011 1 1 RYKA .;- CONSU' T.NG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 v .morrlsonhershfield.00m MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 90x REVIEW BA 0 02/22/21 100x FINAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: EDMONDS WAY/PUD/ BERSCHURE T—MOBILE SITE I.D. SE01632A SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 SHEET NAME: PL_6d�eGE IV DIACb5 202 11 SHEET NUMBER: DEPARTMENT RF-2 24"x36" SCALE: NTS 11"07" SCALE: NTS PLUMBING DIAGRAM 1 1 NOKIA ITEM CODE/SECTOR PRODUCT NAME 474335A FOCZ QSFP+ 400 km SM 474385A FOUF SFP+ 10GBASE—LR 1271 nm CWDM 10 km SM 474386A FOUG SFP+ 10GBASE—LR 1291 nm CWDM 10 km SM 474387A FOUH SFP+ 1OGBASE—LR 1311 nm CWDM 10 km SM 474388A FOUI SFP+ 10GBASE—LR 1331 nm CWDM 10 km SM 474829A AOSB QSFP28 SM 10 km LC FTLX1370W4BTL SM SFP 1310 nm CPRI 9.8G 1.4km (CPRI) 473471A MAFOTA Optical SFP+ 1OGBase—SR 850nm MM FTLXB573D3BTL 1OGb/s 850nm Multimode SFP+ Datacom Transceiver NOTE: JDSU AND EXFO GEAR CAN BE USED TO READ WAVELENGTH ON THE SFPs. -PORT CONNECTION ON THE ARIA MAY VARY AND ARE DESIGNATED AS RFx ('x' CAN BE 1-6) "AHFIB/AHFIG IS ON SAME ABIA IXR—e ...._. NR LTF ARIL ASIK T mo_a s 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA , CONSUL T.NG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W Ww.rrorrlsonhershfield.com MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 90R REVIEW SA 0 02/22/21 10096 FINAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: EDMONDS WAY/PUD/ BERSCHURE T—MOBILE SITE I.D. SE01632A SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 SHEET NAME: TRFEQEIV SECTS)Sff1?202 SHEET NUMBER: DEPARTMENT RF-3 C 24"x36" SCALE: NTS 11"07" SCALE: NTS TYPICAL SECTOR SFP 1 1 GROUNDING KEYNOTES 1O EXISTING EQUIPMENT GROUND BAR. FIELD VERIFY LOCATION. 2 BOND EQUIPMENT CABINET ENCLOSURE USING A MANUF. APPROVED CONNECTION WITH (2) #2 AWG STRANDED GREEN JACKET COPPER CONDUCTORS TO GROUND BAR. 3O #2 AWG STRANDED GREEN JACKET COPPER CONDUCTORS BONDING AAV/ RADIO/JUNCTION BOX/DIPLEXER TO GROUND BAR. ROUTE CONDUCTOR IN 3/4" CONDUIT AS REQUIRED TO ROUTE ALONG WALL & PROTECT FROM DAMAGE O4 NOT USED. POWER UPGRADE NOTE: EXISTING 100A AC SERVICE IS TO BE UPGRADED TO 200A PER SEPARATE ELECTRICAL SERVICE UPGRADE SCOPE OF WORK/DESIGN, UNDER SEPARATE ELECTRICAL PERMIT AS REQUIRED, TO BE INCLUDED IN NTP T .Moi - s 19807 NORTH CREEK PKWY N N BOTHELL, WA 98011 1 1 RYKA .;- CONSU' T.NG 20POSED (1) 2"0 RIGID CONDUIT 'OM EMERSON AC PANEL TO HPL3 )R POWER 2"0 RIGID CONDUIT W/ 1" INNERDUCT W/ (4) SM TO LC (3 MM) FIBER (2) SHIELDED CAT 6 LARMS) (2) #10 THHN DC POWER CABLES FROM N CUBE TO HPL3 CABINET 3SED (1) 2"0 RIGID CONDUIT EACH COVP TO HPL3 FOR POWER LEGEND Tr GROUND BAR EXOTHERMIC CONNECTION a MECHANICAL CONNECTION 1 GROUND PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W Ww.morrlsonheirshfielcl.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 90R REVIEW BA 0 02/22/21 10096 FINAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: EDMONDS WAY/PUD/ BERSCHURE T—MOBILE SITE I.D. SE01632A SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 SHEET NAME: EQ V E LEIW GROUND Zlyi SHEET NUMBER: DEPARTMENT E-1 24"x36" SCALE: NTS 11"0 7" SCALE: NTS SCALE: NITS NOT USED 1 2 1 11:, 7;; SCALE: NTS EQUIPMENT ELECTRICAL/GROUNDING PLAN 11 RED ` DOOR ALARM SWITCH DOOR ALARM BLK DAC ALARM 1 ® }v} HEATER ALARM JSJ9 17�d JB J3 t} DAC ALARM c n DC POWER ALARM J1 J7�1 HEA1}}T�}}} � J8 J3 J274 ®® ® 0 HEATER t�00 HEATER DOOR OPEN DETECT SWITCH CODEX ALARM MODULE INSIDE FRONT DISTRIBUTION COVER DC ALARM WIRING GRN ALARM CABLE 1 WHT LU WHT ORG GR BL OR T (BROWN PAIR F910 & ()(S)(D NOT USED) 70 71 73 74 76 77 K 9 K 10 K 11 DC ALM ALARM AL3 DC MIN AL3 RTN AL4 DC MAJ AL4 RTN AC MAINS HI AILS LOW AL5 RTN 1 DOOR ALM L1 BLK L2 RED VDAC ALM D 3&4 L1 BLK SHELF 1 RED L2 L2 RED GRN V LE]GRN HTR ALM a BLK MDL 5 L2 RED V L1 BLK SHELF 2 BLK L1 DC ALM M L 3&4 L2 RED RED Lz V c I GRN GRN DC MAL V DCPP REAR VIEW AC PWR HULOW AC POWER CONNECTIONS V BAT CAB DOOR V BAT CAB DAC v BAT CAB CBALM V 10 V 11 UPPER LEVEL V TERMINALS I 12 LOWER LEVEL V TERMINALS CABINET BATTERY EXPANSION TO HEATER RELAY HEATER HEATER OPT CABINET IFAI FA IFAI IFAI IFAI IFAI 0000 0000 •000 •00• BLACK RED O ,0 OL20 FIELD WIRING 240VAC SINGLE PHASE 60Hz 200A MAX ON ON ON ON P BLK BLK BLM 3 240VAC DINRAIL ASSEMBLY GREEN WIRES TOCAB MGB 11 X17- SCALE: � ALARM WIRING DIAGRAM 1 4 1 11 x17= SCALE: NETS AC POWER WIRING DIAGRAM 1 3 1 NOTE: DIAGRAMS PROVIDED ARE PER MANUFACTURER INSTALLATION GUIDE THERMAL SYSTEM DAC AND HEATER FUTURE USE FUTURE USE FUTURE USE DC DISTRIBUTION -DOOR OPEN FROM VIEW -TIER"1 iIER"2 t101 0 ®O 0 ° (a O 0. uln rnIP t101 Wltl tlOI 0 m 0 ° 0 0° (o CIL) 0° (a co Oo 0° 00 0° 00 0° o0 0° (a call) (a° 0 m 0- (am) 0° (am 0° 00 0° co)o co)° JUMPER ° CB ^AMARM °CB AMARM r PIN AND SWRCH EIANND SWITCH ORIENTATION ORIENTATION OFF - THERMAL SYSTEM DAC AND HEATER FUTURE USE FUTURE USE FUTURE USE DC DISTRIBUTION TERMINALS iIER"3 iIER"4iIER'4 "TIER"1 OF 4(SIDE VIEW) W�D_T IP II I puL--boAII BLK tl0 (a O 0° AL P ip VOW (a C ME) 0. Oo O° �cu) (0° (o CE:) 0. ° 00 0° 00 0° 00 0° M 0° (o C ME) 0° 0 CID (o° (a CUE) 0° 0 CE) 0 ° (0) cu (0) ° ° CB AMARM CB AMARM PIN AND SWITCH PIN AND SW0 ORIENTATION ORIENTATIOP _ "OFF' OBSERVE CORRECT ALARM PIN ORIENTATION RED TO CABINET DC FUSE BLOCK 1 DAC DOOR PWR 25AIll FUTURE USE 1DA 0 = WOO W W 1 OO W FUTURE USE 1DA mE= W W W W FUTURE USE 10A W W W WW WW FRONT 00 00 WW WW 00 00 00 00 WO 00 WW WW 12 12 WW WW DC-48V HOT BUS DC RETURN (CB FROTECTED) BUS OV(+) T 1VM0LP 1 v-O 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA .;- CONSUL T.NG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W Ww.morrlsonhemhfielcl.wm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 90x REVIEW SA 0 02/22/21 100x FINAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY REAR SITE NAME: EDMONDS WAY/PUD/ BERSCHURE T-MOBILE SITE I.D. SE01632A SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 SHEET NAME: IDIA�nIV May 05 202 SHEET NUMBER: DEPARTMENT E-2 C J 24"x36" SCALE: NITS 11"07" SCALE: NITS NOT USED 12 121 "x36" SCALE: NTS DC POWER WIRING DIAGRAM 11 FROM DC DIN DISTRIBUTION FROM DOOR FROM DC DIN DISTRIBUTION FROM DOOR TO HEATER ELEMENT AC PWR FROM CIRCUIT BREAKER �J1 - TO CABINET SW1 COOL ALARM BLOCK U"U � J8 J9 J7 J8 J3 J2 J4 J9 J7 DAC J8 ALARM S1Y1 HEAT O�U � 7 ja J3 J2 OO ❑ � r�.� J�IJ4 `� l RED O o BLACK O O BLACK RED ±j BLACK RED HEATER ALARM DOOR OPEN DETECT DAC (COOLING) CONTROLLER COHN FUNCTION JI PIWR IN J8 DELTA T JUMPER J9 OUTSIDE TEMPEfATURE J7 DACFAN (LOWER) J6 DACFAN (UPPER) J3 ALARM J2 COOLING INHBIT J4 HEAT REQUEST HEATER CONTROLLER COHN FUNCTION JI PIWR IN J8 HEAT REQUEST J9 COOLING INHBIT J7 UNUSED J6 HEATER FAN J3 ALARM J2 DOOR SW INPUT J4 HEATER REALY CONTROL FROM DIN DISTRIBUTION DOOR OPEN DETECT I121"x17" SCALE: NTS DC CABINET DOOR LIGHT POWER WIRING DIAGRAM 13 TO DOOR V+ UPPER FAN V_ TO DOOR V+ LOWER FAN V_ 6o mm LL U 0 D D 7 U S 6aFa 00 m -ED LIGHT FROM DC PLANT 25A DC DISTRIBUTION (BLACK WIRE JUMPERS TO FUSE POSOTIONS REMOVED FOR CLARITY) T mo_a s 198117 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA .;- CONSU' T.NG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W W W.morrisonhershfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 90R REVIEW BA 0 02/22/21 100x FINAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY EDMONDS WAY/PUD/ BERSCHURE T—MOBILE SITE I.D. SE01632A SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 SHEET NAME: May 05 202 77, SHEET NUMBER: E DEPARTMENT E-3 C NNW SCALE: NTS 11"07" SCALE: NTS SCALE: NTS DC HEATING AND COOLING WIRING DIAGRAM 12 1 1107" SCALE: NTS DC FUSE BLOCK WIRING DIAGRAM 11 GROUNDING KEYNOTES TYF RAD CENTER 70'-6$$ RAD CENTER 60'-0" TYP TYP ONOT USED. ONOT USED. OEXISTING ANTENNA CABLE GROUND BAR. BOND ANTENNA CABLE GROUNDING KITS TO GROUND BAR. CONNECTION SHALL BE THE RESPONSIBILITY OF THE ANTENNA CABLE INSTALLER. BOND GROUND BAR TO TOWER USING ONE (1) #2 AWG SOLID TINNED COPPER CONDUCTOR. PROVIDE A U.L LISTED CONNECTOR SUITABLE FOR THE MATERIALS BEING CONNECTED. PROVIDE EXOTHERMIC WELDS FOR BONDS TO STEEL BEAM OR FRAME. ONOT USED. O5 PROPOSED T—MOBILE ANTENNA AND RADIOS PER PLAN. OEXISTING GROUNDING CONDUCTOR BONDED TO ANTENNA PIPE MOUNT. OBOND PROPOSED RADIO UNIT TO AGO WITH #2 AWG STRANDED GREEN JACKET COPPER CONDUCTOR. I GROUNDING NOTES 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. 2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METALLIC COMPONENTS USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED BUS BARS. FOLLOW ANTENNA AND BTS MANUFACTURERS PRACTICES FOR GROUNDING REQUIREMENTS. GROUND COAX SHIELD AT BOTH ENDS AND EXIT FROM TOWER OR POLE USING MFR'S PRACTICES. 3. ALL GROUND CONNECTIONS SHALL BE CADWELD AND CLEANED THOROUGHLY THEN COVERED WITH TWO (2) COATS OF SERWIN WILLIAMS GALVANTE PAINT B350W3 OR EQUAL. SEE 4. ALL WIRES SHALL BE COPPER THHN/THWN. ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE ABOVE GROUND. 5. ALL ELECTRICAL CADWELD AND MECHANICAL CONNECTIONS SHALL HAVE NON —OXIDATION COMPOUND APPLIED TO CONNECTION. 6. ALL MATERIALS AND CADWELD MOLDS, SHOTS, ETC. SHALL BE FURNISHED AND INSTALLED BY CONTRACTOR UNLESS OTHERWISE NOTED. 7. REFER TO DIVISION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL PROVISION AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING STANDARDS. 8. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. 9. USE PANI SCHEME FOR LOADING GROUNDS ON MGB AS DISCUSSED IN NSTD 119, 33 & 36. LEGEND Tr GROUND BAR EXOTHERMIC CONNECTION MECHANICAL CONNECTION 1 GROUND NOTES: 1. BOND EQUIPMENT TO GROUND BAR(S) PER MANUFACTURER SPECS 2. CONTRACTOR TO REPLACE ALL MISSING GROUND BAR AND GROUNDING CONNECTIONS AS REQUIRED T .Mo_a s 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA .;- CONSUL T.NG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 v .morrlsonhershfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 90x REVIEW BA 0 02/22/21 100x FINAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY LICENSURE: SITE NAME: EDMONDS WAY/PUD/ BERSCHURE T—MOBILE SITE I.D. SE01632A SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 SHEET NAME: G RMI V SCHE A*P8 202 SHEET NUMBER: DEPARTMENT E-4 C 24"x36" SCALE: NTS 11"07" SCALE: NTS ANTENNA GROUNDING SCHEMATIC 1 1 NOTES: 1. COAT ALL MECHANICAL CONNECTIONS WITH "NO—OX" OR APPROVED EQUAL 2. ALL EXISTING & NEW TOWER GROUNDING BARS SHALL BE ATTACHED DIRECTLY TO THE TOWER WITHOUT ISOLATORS; NO WELDING OR DRILLING PERMITTED 3. EXISTING HOME RUN GROUND(S) TO BE REMOVED NEW COAXIAL GROUND KITS W/ LONG BARREL COMPRESSION DOUBLE LUGS, ATTACH TO GROUND BAR & INSTALL BY ANTENNA CONTRACTOR (CADWELD TYPE—GL) NEW 1/4" THK COPPER GROUND BAR, INSTALLED BY GENERAL CONTRACTOR r ___1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 20" MGB OR 10" ANTENNA AGB FIELD VERIFY #2 AWG SOLID BARE TINNED COPPER GROUND WIRE (TYPE GL) STRANDED CU WIRE WITH GREEN, 600V, THHN/THWN INSULATION. SIZE AS SPECIFIED COPPER GROUND BAR ON WALL. OR ONEANTENNA TOWER I I� PANI SCHEME SPECIFICATIONS: PRODUCER (P) CONNECTS TO WIRELESS EQUIPMENT CABINETS, CABLE ENTRANCE GROUND BAR (CEGB), MAIN DISTRIBUTION FRAME GROUND BAR (MDFB), AND STANDBY ENGINE G ENERATOR SET FRAME AND OTHER NOISE PRODUCING EQUIPMENT. ABSORBER (Al CONNECTS TO THE EARTH ELECTRODE SYSTEM INCLUDING CENTRAL OFFICE GROUND GRID, BUILDING STRUCTURAL GROUND, METALLIC WATER PIPE SYSTEM, ANTENNA SUPPORTING STRUCTURE GROUND SYSTEM, AND ELECTRICAL SERVICE ENTRANCE GROUND. NON —ISOLATED (N) CONNECTS TO EQUIPMENT NOT IN AN ISOLATED GROUND ZONE (IGZ) SUCH AS CBN EQUIPMENT FRAME GROUNDS AND DC GROUND CONDUCTORS FOR DC POWER SYSTEMS THAT SERVE CBN OR BOTH CBN AND IBN EQUIPMENT ISOLATED (1) CONNECTS TO THE SINGLE POINT CONNECTION BAR (SPCB) FOR IBN EQUIPMENT ���w«��; 01 • �0l0 00 P. TWO HOLE LUG, BOLTED TO GROUND BAR USING 3/8"-16X1/4" STAINLESS STEEL HEX HEAD BOLTS AND HARDWARE `TWO HOLE LUG, TO BE USED WITH #2 AWG SOLID TINNED BARE CU WIRE OR STRANDED CU WIRE WITH GREEN, 60OV, TO ANTENNA STRUCTURE, BUILDING RING GROUND OR MGB NOTE: *GROUND BARS AT BOTTOM OF TOWERS OR MONOPOLES SHALL USE EXOTHERMIC CONNECTION N (TYPICALLY) \� 12" TO 24" a o 120" MAX. ANTENNA CABLE"GROUND CABLE CONNECTOR WEATHERPROOFING KIT (SEE NOTE 3)STRANDED COPPER WIRE (GROUNDED TO CABLE GROUND KIT BAR). SEE NOTE 1 & 2 NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 3. WEATHER PROOFING SHALL BE TWO—PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. 1111"x7" SCALE: NITS GROUND BAR 6 11"x17" SCALE: NTS x36" SCALE: NITS 1 GRND CABLE CONNECTION 5 11 "x17" SCALE: NITS COAX CABLE GROUNDING 141 TO ANTENNAS COAX JUMPER (TYP) CONNECTOR WEATHERPROOFING KIT (TYP) SEE NOTE 2 ANTENNA CABLE TO BTS EQUIPMENT (TYP) VEATHERPROOFING :IT (TYP) ROUND KIT (TYP) 16 AWG TOPPER ANTENNA GROUND AIR, ATTACHED DIRECTLY TO OWER WITHOUT ISOLATOR. 10 WELDING OR DRILLING 'ERMITTED. TO GROUND RING NOTES: DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. WEATHER PROOFING SHALL BE TWO—PART TAPE KIT. COLD SHRINK SHALL NOT BE USED. T Molk s 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA .;- CONSU' T.NG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STEEL, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W Ww.morrisonhershfield.wm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 01/21/21 90x REVIEW BA 0 02/22/21 100x FINAL LW SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: EDMONDS WAY/PUD/ BERSCHURE T—MOBILE SITE I.D. SE01632A SITE ADDRESS: 9726 EDMONDS WAY EDMONDS, WA 98020 SHEET NAME: GRAEGME IV DET194KA5 202 SHEET NUMBER: DEPARTMENT E-5 C 24"x36" SCALE: NTS 11"07" SCALE: NITS GRND CABLE CONNECTION 13 1 SCALE, NTS 11 x37" SCALE: NITS NOT USED 1 2 1 11"X17- SCALE: Nn CADWELD 1 1