Loading...
FIR2021-0126+Fire_Alarm_Plan+11.16.2021_8.10.01_AM+2521890�4t�r�i H CO O� H Mims C C � O O V �o ILL== I 0 73 o00 ��� U)00 NNN = 000 �00 NNN aC6 C) Nod rn U) U) U) G4 ao rn rn co .--� W to d� a00 0 rn r- o a� to ►1.0 m o a � � CID o 0 a w z w x � (n A c� z H A EF Q A U U w a O Wa E- E-E A w A O U � a F O U W a 0 U] E w U z 0 A 124 �-.1-4 r�-I Cz O Approved by Fire Go 1 00 00 1 0 11 /30/2021 w 'i CQ CQ AFM /��ctt��2r co A co0 rn .� 0 Approved, Subject to field inspection after contractor pre -testing z 02 DRAWINGS REVIEWED BY.• Chad McCammon, SET NICET #090810 O O Fire Alarm Systems, Level IV rm n e c M E4 Eq W E-1 U I' men t Supp d y F-1 o nsonDRAWING LIST z 0 ELECTRONIC INCLUDED SHEET NAME DRAWING NAME DRAWING IN THIS Q NAME PROJECTontro s W FA—COV-01 TITLE SHEET FA—COV-01 X FA—COV-02 COVER SHEET FA—COV-02 X W E4 FA—COV-03 COVER SHEET FA—COV-02 FA—COV-04 COVER SHEET FA—COV-02 FA—RIS-01 RISER SHEET FA —COVER W FA—DET-01 DETAIL SHEET FA—DET-01 FA—DET-02 DETAIL SHEET FA—DET-01 X FA—DET-03 DETAIL SHEET FA—DET-03 Q W Project c t Team Contact Information FA—B-01 D BASEMENT DEMO PLAN FA—B-01 D X � J w FA-13-01 BASEMENT PLAN FA—B-01 X x z Sales Representative: Lyle Fortin lyle.fortin©jci.com (206 777-4838 w ) FA—F-01 N FIRST FLOOR PLAN NORTH FA—F-01 N � � Q < Project Engineer: ,lames Beesley james.beesley@jci.com FA—F-01 E FIRST FLOOR PLAN EAST FA—F-01 W Q 0 J 9 Y j Y 1 (206) 777-4827 W FA—F-01 W FIRST FLOOR PLAN WEST FA—F-01 W o ° Project Coordinator: Cheryl Graves cheryl.groves@jci.com (206) 777-4816 U� N w ~ � o FA—F-02E SECOND FLOOR TOWER EAST FA—F-02W Technician Scheduler: Yvonne Thompson yvonne.thompson©jci.com (206) 777-4860 FA—F-02T SECOND FLOOR TOWER FA—F-02T w APPROVED BY: a S.R.B. FA—F-03T THIRD FLOOR TOWER FA—F-03T Z z DRAWN BY: RECEIVED FA—F-04E THIRD FLOOR TOWER EAST FA—F-04E � o FA—F-04T THIRD FLOOR TOWER FA—F-04T G.O.K. Nov 16 2021 DATE: CITY F EDM ND DEVELOPMENT SERVICES FA—F-05 FIFTH FLOOR TOWER FA—F-05 Y DEPARTMENT 8-1-94 FA—F-06 SIXTH FLOOR TOWER FA—F-06 3 PROJECT NUMBER: FA—F-07 SEVENTH FLOOR TOWER FA—F-07 458-90031 FA—F-08 EIGHTH FLOOR TOWER FA—F-08 FA—F-09 NINTH FLOOR TOWER FA—F-09 FA—R-01 ROOF FLOOR TOWER FA—R-01 O SHEET NUMBER: 0 FA—COV-01 FIR2021-0126 Q a GENERAL FIRE ALARM SYSTEM NOTES 1) FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE, SPECIFICATIONS AND CONTRACT DOCUMENTS OR AHJ. 2) ALL RACEWAYS MUST BE FREE OF MOISTURE 3) REFER TO JOHNSON CONTROLS FIRE ALARM DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE MOUNTING ELECTRICAL BOXES. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROPER INSTALLATION OF ALL DEVICES. 4) AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING. 5) UNRELATED (NON -FIRE ALARM) WIRING SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRING. 6) ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITED AND NON POWER -LIMITED WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7) ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS- T-TAPPING OF ZONE CIRCUITS AND SIGNAL CIRCUITS IS NOT PERMITTED. 8) REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. VERIFY ALL CONNECTIONS WITH A JOHNSON CONTROLS FIELD TECHNICAL REPRESENTATIVE PRIOR TO TERMINATION. 9) ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS AND GROUNDS. 10) ALL WIRING SHALL BE LABELED AND TAGGED 11) ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR INSTALLATION AND MAKING ALL FINAL CONNECTIONS PRIOR TO JOB CHECKOUT AND FINAL TESTING BY A JOHNSON CONTROLS FIELD TECHNICAL REPRESENTATIVE. CALL A MINIMUM OF 5 DAYS IN ADVANCE TO SCHEDULE A JOHNSON CONTROLS TECHNICIAN AT (206) 777-4860 12) ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR MAKING ALL ARRANGEMENTS FOR INSPECTION, TEST AND CERTIFICATION OF THE FIRE ALARM SYSTEM BY ALL APPROPRIATE AUTHORITIES. 13) UPON WRITTEN REQUEST, JOHNSON CONTROLS WILL PROVIDE WRITTEN INSTRUCTIONS REGARDING THE APPROPRIATE WIRE/CABLE FOR INSTALLATION OF THE EQUIPMENT/SYSTEM(S) IDENTIFIED IN THESE DRAWINGS. JOHNSON CONTROLS SHALL NOT BE RESPONSIBLE FOR PROBLEMS OR DAMAGES RESULTING FROM THE USE OF WIRE/CABLE OTHER THAN THAT WHICH HAS BEEN IDENTIFIED IN WRITING BY JOHNSON CONTROLS FOR A SPECIFIC APPLICATION. 14) ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW VOLTAGE WIRING. ARCHITECT: N/A FIRE ALARM SYSTEM DESIGNED BY: JOHNSON CONTROLS SEATTLE, WA FIRE ALARM SYSTEM INSTALLED BY: COCHRAN, INC SEATTLE, WA EQUIPMENT FOR FIRE ALARM SYSTEM SUPPLIED BY: JOHNSON CONTROLS SEATTLE, WA WASHINGTON STATE ELECTRICAL CONTRACTORS NUMBER: JOHNSCP831PR * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA. MAIN FACP SPEAKER CIRCUITS POWER CONSUMPTION 1-2) NOT USED 3 2ND FLOOR TOWER 20W 4 2ND FLOOR EAST 20W 5 3RD FLOOR TOWER 16W 6 3RD FLOOR EAST 16W 7 4TH FLOOR TOWER 15W 8 4TH FLOOR EAST 4W 9 5TH FLOOR TOWER 15W 10) 6TH FLOOR TOWER 18W 11-14) SPARES STROBE CIRCUITS 11014Ill =11Nelr 15 2ND FLOOR TOWER VD= 1.52V 16 2ND FLOOR EAST VD= 3.58V 17 3RD FLOOR TOWER VD= 1.44V 18 3RD FLOOR EAST VD= 2.51 V 19 4TH FLOOR TOWER VD= 1.01 V 20) 4TH FLOOR EAST VD= .1OV 21) 5TH FLOOR TOWER VD= .78V 22) 6TH FLOOR TOWER VD= .80V 23-26) SPARES AUXILIARY CONTACTS 1-2) NOT USED 3 2ND FLOOR TOWER DOOR HOLDERS 4 2ND FLOOR EAST DOOR HOLDERS/CLOSERS 5 3RD FLOOR TOWER DOOR HOLDERS 6 3RD FLOOR EAST DOOR HOLDERS/CLOSERS 7 4TH FLOOR TOWER DOOR HOLDERS 8 5TH FLOOR TOWER DOOR HOLDERS/CLOSERS 9 6TH FLOOR TOWER DOOR HOLDERS/CLOSERS 10) SUPERVISORY CONTACT 11) WATERFLOW ALARM 12-18) SPARE GENERATOR INTERFACE PANEL 24 POINT I/O 1) GENERATOR RUNNING 2 LOW WATER TEMPERATURE 3 APPROACH LOW OIL PRESSURE 4 APPROACH HIGH WATER TEMPERATURE 5 BATTERY CHARGER FAILURE 6 OVERSPEED 7 OVERCRANK 8 OVERCURRENT 9 LOW LUBE OIL PRESSURE 10) HIGH WATER TEMPERATURE 11) LOW COOLANT LEVEL 12 LOW FUEL MAIN TANK 13 LOW FUEL DAY TANK 14 HIGH FUEL DAY TANK 15-24) SPARE M Z (/) _0 m o I = m D m D -0 I' -0 m W CA m r_ O m 1 D M D M C� = � K a � 1 � rrl SEQUENCE OF c o O rri7z Z f Tl z OPERA TION r __j Z o m r z U-) , C7 D m n = o � O OC � Z O Z Z O Z O— 0 E� o 00 fMT1 r= M cmn CTIVATION OF LOCAL ALARM AT FACP X X X X X X X LCD DISK, ZONE LED & AUDIBLE INDICATION CTIVATE ALL AUDIBLE ALARMS X X X X X X X 2 ROUNDS CHIME TONE W VOICE CODE CTIVATE ALL AUDIBLE DEVICES ON HIRE FLOOR, X X X X X X OOR ABOVE & BELOW AFTER PREVIOUS SIGNAL CTIVATE VISUAL ALARM ON FIRE FLOOR ONLY X X X X X X TRANSMIT ALARM SIGNAL TO X X X X X X X ENTRAL STATION MONITOR INDATNO 4LARN LCD X X X X X X NN NNCIA ORI,C RTIOANDPRINTER ONE INDICATION AT NURSES STATION X X X X X NNUNCIATOR ON FIRE FLOOR SHUTDOWN RESPECTIVE HVAC UNIT X NITIATE PRIMARY ELEVATOR RECALL X SEQUENCE SEE MATRIX PER BANK NITIATE ALTERNATE ELEVATOR RECALL X SEQUENCE SEE MATRIX PER BANK RELEASE ALL ELEC. LOCKS ON FIRE FLOOR X X X X X X ELEASE ALL DOOR HOLDERS CLOSERS ON RRE FLOOR X X X X X X OUBLE SUPV INDICATION AT FACP, XXXX X CD ANNUNCIATOR, CRT AND PRINTER TRANSMIT TROUBLE SUPV SIGNAL X X X X 0 CENTRAL STA ION MONITOR RIORITY 2 ALARM INDICATION AT FACP, X CD ANNUNCIATOR, CRT & PRINTER TRANSPONDER #1 SPEAKER CIRCUITS ELECTRICAL CONTRACTOR ELECTRICAL CONTRACTOR IS TO SCHEDULE A PRELIMINARY SITE MEETING WITH A JOHNSON CONTROLS TECHNICAL REPRESENTATIVE. THESE MEETINGS ARE FOR REVIEWING EQUIPMENT LISTS, INSTALLATION PROCEDURES, AND PROVIDING ANSWERS TO QUESTIONS RELATIVE TO SYSTEM INSTALLATION. PLEASE ALLOW A MINIMUM OF TEN WORKING DAYS ADVANCE NOTICE TO SCHEDULE A TECHNICAL REPRESENTATIVE. - TO SCHEDULE A MEETING PLEASE CONTACT OUR OPERATIONS DEPARTMENT AT (206) 777-4860. - DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET POWER CONSUMPTION 25W A20 30) 1ST FLOOR EAST 29W 31) 1 ST FLOOR WEST 30.5W 32 1ST FLOOR SOUTH 19W 33 ELEVATOR #5 1W 34 ELEVATORS #6 & 7 2W 35 ELEVATOR #8 1W 36-38) SPARE STROBE CIRCUITS VOLTAGE DROP 40 BvSM N VD= 3.12V 20 42 1ST FLOOR EAST VD= 1.65V 43 1ST FLOOR WEST VD= 1.19V 44 1ST FLOOR SOUTH VD= 4.30V 57 1ST FLOOR EAST VD= .773V 69 1ST FLOOR CATH LAB VD= 3.45V 72 1ST FLOOR RME VD= .66V AUXILIARY CONTACTS 19) PRIMARY ELEV. RECALL ELEVATOR #5 20) ALTERNATE ELEV. RECALL ELEVATOR #5 21) PRIMARY ELEV. RECALL ELEVATORS #6 & 7 22 ALTERNATE ELEV. RECALL ELEVATORS #6 & 7 23 PRIMARY ELEV. RECALL ELEVATOR #8 24 ALTERNATE ELEV. RECALL ELEVATOR #8 25 BASEMENT DOOR HOLDERS 26 1ST FLOOR DOOR HOLDERS/CLOSERS 35 1ST FLOOR DOORHOLDERS CLOSERS 36 1ST FLOOR FIRE/SMOKE DAMPER CATH LAB 37-38) SPARE SPEAKER SELECT SW. 1) SUB -BASEMENT 2 BASMENT 3 1ST FLOOR WEST/CENTRAL 4 1ST FLOOR EAST/SOUTH 5 2ND FLOOR TOWER 6 2ND FLOOR EAST 7 3RD FLOOR TOWER 8 3RD FLOOR EAST 9 4TH FLOOR TOWER 10) 4TH FLOOR EAST 11) 5TH FLOOR TOWER 12 6TH FLOOR TOWER 13 7TH FLOOR TOWER 14 8TH FLOOR TOWER 15 9TH FLOOR TOWER 16 PENTHOUSE TOWER 17 ELEVATORS #1 & 2 18 ELEVATORS #3 & 4 19 ELEVATOR #5 20) ELEVATORS #6 & 7 21) ELEVATOR #8 22) CENTRAL PLANT 23-24) SPARE TRANSPONDER #2 SPEAKER CIRCUITS SCOPE OF WORK: MODIFICATION TO FIRE ALARM SYSTEM IN BASEMENT. REMOVE DEVICES AS SHOWN ON SHEET F-B-01BD AND ADD DEVICES TO OPERATING ROOM CLEAN CORRIDOR AS SHOWN ON SHEET F-B-01 POWER CONSUMPTION 45 7TH FLOOR TOWER 18W 46 8TH FLOOR TOWER 14W 47 9TH FLOOR TOWER 14W 48 PENTHOUSE TOWER 6W 49 ELEVATORS #1 & 2 2W 50 ELEVATORS #3 & 4 2W STROBE CIRCUITS ffel4rTe111 NO] 51) 7TH FLOOR TOWER VD= .19V 52 8TH FLOOR TOWER VD= 1.08V 53 9TH FLOOR TOWER VD= 1.07V 54 PENTHOUSE TOWER VD= .04V 55 9TH FLOOR TOWER VD= .47V 56) SPARE AUXILIARY CONTACTS 27 PRIMARY ELEV. RECALL ELEVATORS #1 & 2 28 ALTERNATE ELEV. RECALL ELEVATORS #1 & 2 29 PRIMARY ELEV. RECALL ELEVATORS #3 & 4 30 ALTERNATE ELEV. RECALL ELEVATORS #3 & 4 31) 7TH FLOOR DOOR HOLDERS/CLOSERS 32 8TH FLOOR DOOR HOLDERS/CLOSERS 33 9TH FLOOR DOOR HOLDERS/CLOSERS 34 INFANT ABDUCTION SYSTEM 39 CLOCK RESET 40-46) SPARE ADDRESSABLE DETECTOR IDENTIFICATION MODULE/CIRCUIT # X - X DEVICE # 24 POINT I/O TRANSPONDER #3 SPEAKER CIRCUITS WIRING CODE ALL WIRING TO MEET NEC ART. 760 CODE REQUIREMENTS LETTER QTY COLOR SIZE FUNCTION A 1 BLACK 16 ZONE 1 ORANGE 16 C 1 RED 14 STROBE 1 BLUE 14 D 2 RED 14 STROBE LOOP 2 BLUE 14 E MATCH EXISTING DOOR HOLDER/CLOSER COLOR SCHEME AND SIZE F 2 ORANGE 14 FAN SHUTDOWN H 1 W.PENN D975 18 SERIAL ANNUNCIATOR 1 RED 14 1 BLACK 14 J 1 TW/SHLD PR. 16 SPEAKER K 2 TW/SHLD PR. 16 SPEAKER LOOP L 2 YELLOW 14 ELEVATOR RECALL M 1 PINK 16 SECURITY MONITOR SW. 1 WHITE 16 N 2 W.PENN D975 18 MINIPLEX COMM. 2 TW/SHLD PR. 16 MINIPLEX AUDIO P 1 RED 14 24VDC POWER 1 BLACK 14 Q 1 BROWN 14 INFANT ABDUCTION SYSTEM 1 YELLOW 14 R 1 BLUE 16 REMOTE LED 1 WHITE 16 S 1 GRAY 14 DOOR LOCKS 1 BLUE 14 T 6 PURPLE 14 DIALER 6 YELLOW 14 U 2 W.PENN D975 18 NETWORK (ONCOLOGY) V 1 W.PENN 3244 18 PRINTER/CRT W 2 FIBER OPTIC LINES NETWORK (WARREN BLDG) X 1 W.PENN D975 18 ADDR. MAPNET DATA LINE STYLE 4 Y 1 PURPLE/WHITE 14 SMOKE DAMPER 1 PURPLE 14 Z EXISTING EXISTING DOOR HOLDER/ CLOSER NOTES: 1) TAG AND IDENTIFY ALL ZONE WIRES WITH ZONE NUMBER. 2) TAG AND IDENTIFY ALL SIGNAL CIRCUIT WIRES WITH SIGNAL CIRCUIT NUMBER. 3) TAG AND IDENTIFY ALL ANNUNCIATOR WIRES. POWER CONSUMPTION QCENTRAL PLANT 15W SPARE STROBE CIRCUITS 59) CENTRAL PLANT 60 SPARE AUXILIARY CONTACTS 39-46) SPARE 25 GENERATOR RUNNING GENERATOR 1 26 GENERATOR RUNNING GENERATOR 2 27 LOW WATER TEMPERATURE GENERATOR 1 28 LOW WATER TEMPERATURE GENERATOR 2 29 APPROACH LOW OIL PRESSURE GENERATOR 1 30 APPROACH LOW OIL PRESSURE GENERATOR 2 31) APPROACH HIGH WATER TEMPERATURE GENERATOR 1 32 APPROACH HIGH WATER TEMPERATURE GENERATOR 2 33 BATTERY CHARGER FAILURE GENERATOR 1 34 BATTERY CHARGER FAILURE GENERATOR 2 35 CONTROL VOLTAGE FAILURE GENERATOR 1 36 CONTROL VOLTAGE FAILURE GENERATOR 2 37 OVERSPEED GENERATOR 1 38 OVERSPEED GENERATOR 2 39 OVERCRANK GENERATOR 1 40 OVERCRANK GENERATOR 2 41) REVERSE POWER GENERATOR 1 42 REVERSE POWER GENERATOR 2 43 OVER CURRENT GENERATOR 1 44 OVER CURRENT GENERATOR 2 45 FAILURE TO SYNCHRONIZE GENERATOR 1 46 FAILURE TO SYNCHRONIZE GENERATOR 2 47 LOW LUBE OIL PRESSURE GENERATOR 1 48 LOW LUBE OIL PRESSURE GENERATOR 2 49 HIGH WATER TEMPERATURE GENERATOR 1 50 HIGH WATER TEMPERATURE GENERATOR 2 51) GENERATOR LOCKED OUT GENERATOR 1 52 GENERATOR LOCKED OUT GENERATOR 2 53 LOW COOLENT LEVEL GENERATOR 1 54 LOW COOLENT LEVEL GENERATOR 2 55 LOW FUEL MAIN TANK 56 FUEL LEAK MAIN TANK 57 LOW FUEL DAY TANK #1 VOLTAGE DROP VD= 1.38V 58 HIGH FUEL DAY TANK #1 59 DAY TANK #1 RUPTURE 60 LOW FUEL DAY TANK #2 61) HIGH FUEL DAY TANK #2 62 DAY TANK #2 RUPTURE 63 CONTROL NOT IN AUTOMATIC 64 CRITICAL CONTROL VOLTAGE FAILURE 65 AC CONTROL VOLTAGE FAILURE 66 GROUND FAULT 67 TRANSFER SWITCH ATS-X-NORMAL 68 TRANSFER SWITCH ATS-X-GENERATOR 69 TRANSFER SWITCH ATS-X-BYPASS 70 TRANSFER SWITCH ATS-Y-NORMAL 71) TRANSFER SWITCH ATS-Y-GENERATOR 72 TRANSFER SWITCH ATS-Y-BYPASS 73 TRANSFER SWITCH ATS-Z-NORMAL 74 TRANSFER SWITCH ATS-Z-GENERATOR 75 SPARE 76 TRANSFER SWITCH ATS-EL-NORMAL 77 TRANSFER SWITCH ATS-EL-GENERATOR 78 TRANSFER SWITCH ATS-OP-NORMAL 79 TRANSFER SWITCH ATS-OP-GENERATOR 80 TRANSFER SWITCH ATS-CP-NORMAL 81) TRANSFER SWITCH ATS-CP-GENERATOR 82 FUEL OIL LEAK DETECTION ALARM 83 ELECTRONIC METERING SWBD CP ALARM 84 ELECTRONIC METERING SWBD CP WARNING 85 ELECTRONIC METERING SWBD HP ALARM 86 ELECTRONIC METERING SWBD HP WARNING 87 ELECTRONIC METERING SWBD 2 ALARM 88 ELECTRONIC METERING SWBD 2 WARNING 89 ELECTRONIC METERING SWBD 3 ALARM 90 ELECTRONIC METERING SWBD 3 WARNING 91-96) SPARE LEGEND SYMBOL DESCRIPTION MODEL # BACK BOX ❑F ADDR. MANUAL PULL STATION 2099-9795 W/ (2) GANGABLE BOX 1-2 2099-9813 TRIM 3 X 2 X 2.75 BY EC ❑F ADDR. MANUAL PULL STATION 4099-9004 1-GANG BY EC 1-2 Mxxcd MULTICANDELA SPEAKER/STROBE E70-24MCW-FW 4" SQ 2-1/8" DEEP W/ 2 * SUBSCRIPT INDICATES CIRCUIT If & CANDELLA SETTING 1,5" EXT BY EC 15cd SPEAKER/STROBE 15/75cd E70-241575W-FR 4" SQ DEEP W/ 2 * SUBSCRIPT INDICATES CIRCUIT # 1.5" EXT BY EC ® Mxxcd SPEAKER/STROBE MC, CEILING E90-24MCC-FW 4" SQ DEEP W/ 2 * SUBSCRIPT INDICATES CIRCUIT # & CANDELLA SETTING 1.5" EXT BY EC lzzcd SPEAKER STROBE 177cd, CEILING E90-24MCCH-FW 4" SQ DEEP W/ * SUBSCRIPT INDICATES CIRCUIT # & CANDELLA SETTING 1.5" EXT BY EC 75cd A/V SPEAKER/STROBE 4903-9187 4" SQ. BY EC 2 * SUBSCRIPT INDICATES CIRCUIT # 15cd STROBE 15/75cd RSS-241575W-FR SG BY EC 2 * SUBSCRIPT INDICATES CIRCUIT # Mxxcd L� MULTICANDELA STROBE STW 1-GANG BY EC 2 * SUBSCRIPT INDICATES CIRCUIT # 2�2 15cd V/0 STROBE 4904-9137 1-GANG BY EC * SUBSCRIPT INDICATES CIRCUIT # FL I 15cd STROBE 15/75cd RSS-241575W-FR SG BY EC 2 * SUBSCRIPT INDICATES CIRCUIT # n^15cd LJ� STROBE 15cd 4904-9176 SG BY EC 2 * SUBSCRIPT INDICATES CIRCUIT # ® xxcd MULTICANDELA CEILING STROBE STWC SG BY EC * SUBSCRIPT INDICATES CIRCUIT # & CANDELA SETTING ®Mxxcd MULTICANDELA CEILING STROBE RSS-24MCC-FW SG BY EC * SUBSCRIPT INDICATES CIRCUIT # & CANDELA SETTING FDSMI DUAL SYNCHRONOUS MODULE DSM-12/24-R 4 11 /16" SQ DEEP BY EC QQ CEILING SPEAKER E-9025-W OR/ 4" SQ DEEP W/ 2 * SUBSCRIPT INDICATES CIRCUIT # 4902-9721 /E90 1 1 /2" EXT. BY EC (EH WALL SPEAKER E-7025-W 4" SQ DEEP W/ 2 * SUBSCRIPT INDICATES CIRCUIT # 1 1 /2" EXT. BY EC QQ -I WALL SPEAKER 4902-9716 4" SQ DEEP W/ 2 * SUBSCRIPT INDICATES CIRCUIT # " 1-2 1-2 a1-2 0 1-2 �D DD DR Q 1-2 OF O F IAM 1-2 IM 1-2 cz 1-2 sz 1-2 RI 1-2 RI 1-2 D RR ❑M F DH F DH S FS PS DL DS P❑ OFA SD cs MD REL SOL HALON TC PTR CRT AR LCD GIP TPR NAC FACP 4010 TRUEALARM PHOTO. SMOKE DETECTOR TRUEALARM PHOTO. SMOKE DETECTOR SMOKE SENSOR W/ BASE TRUEALARM DUCT DETECTOR TRUEALARM DUCT SENSOR REMOTE LED REMOTE LED W/TEST DUCT DETECTOR RELAY TRUEALARM HEAT DETECTOR FT 135 HEAT DETECTOR FT 200 HEAT DETECTOR TRUEALARM HEAT SENSOR ADDR. MONITOR IAM SUPERVISED IAM * SUBSCRIPT INDICATES DEVICE ADDRESS ADDR. CONTROL ZAM SIGNAL ZAM RELAY IAM * SUBSCRIPT INDICATES DEVICE ADDRESS DUAL CONTACT RELAY IAM * SUBSCRIPT INDICATES DEVICE ADDRESS REMOTE RELAY REMOTE RELAY-DPDT WALL MOUNTED DOOR HOLDER FLOOR MOUNTED DOOR HOLDER DOOR HOLDER, FLUSH MOUNT DOOR HOLDER, SURFACE MOUNT FLOW SWITCH TAMPER SWITCH PRESSURE SWITCH DOOR LOCK SECURITY DOOR SWITCH PANIC BUTTON KITCHEN HOOD CONNECTION EQUIPMENT/WIRING CONNECTION SMOKE DAMPER COIL SUPERVISION MODULE MAINTENANCE DISCONNECT SWITCH SUPPRESSION RELEASE PERIPHERAL SOLENOID JUNCTION BOX HALON PANEL TERMINAL CABINET (MIN. 12" X 12") SYSTEM PRINTER CRT/KEYBOARD SERIAL NURSES' STATION ANNUN. PBX SERIAL LCD ANNUNCIATOR 4098-9701 W/ 4098-9781 BASE 4098-9714 W/ 4098-9789 BASE 4098-9714 W/ 4098-9792 4098-9702 4098-9756 2098-9808 2098-9806 4098-9843 2098-9806 4098-9731 W/ 4098-9781 BASE 2098-9445 2098-9440 4098-9733 W/ 4098-9789 BASE 2190-9172A 4090-9001 2190-9163 2190-9161 4090-9002 4090-9008 2088-9008 2088-9010 2088-9608 2088-9610 DH24120FPC DH24120SPC BY EC BY EC BY EC EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING 2081-9046 2080-9060 4090-9006 BY OTHERS BY EC EXISTING BY EC 2190-9038 2190-9042 4602-9101 4603-9101 W/ GENERATOR INTERFACE PANEL 4120-8009 MINIPLEX TRANSPONDER 4120-8019 NAC PANEL 4009-9201 FIRE ALARM CONTROL PANEL 4120-8210 4010 4010-9402 NOTE: EC= ELECTRICAL CONTRACTOR PROVIDED NEW WIRE/RACEWAY EXISTING RACEWAY TO REMAIN 1 1 /2 EXT. BY EC 4" OCT BY EC 4" OCT BY EC 4" OCT BY EC SELF CONTAINED SELF-CONTAINED SG BY EC SG BY EC 4" SQ W/SG & COVER BY EC 4" OCT BY EC 4" OCT BY EC 4" OCT BY EC 4" OCT BY EC 4" SQ. DEEP W/ COVER BY EC 1-GANG W/4090-9810 BKT & 4090-9807 PLATE 4 11 /16" SQ. DEEP W/ 1 1 /2" EXT. BY EC 4 11 /16" SQ. W/ 2-1/8" DEEP BY EC 1-GANG W/4090-9810 BKT & 4090-9807 PLATE 4 11 /16" SQ. DEEP W/ 4090-9813 ADAPTER PLATE SELF CONTAINED SELF CONTAINED 1-GANG BY EC 1-GANG BY EC SG BOX 2 1 /8" DEEP BY EC SG BOX 2 1 /8" DEEP BY EC BY EC BY EC BY EC EXISTING EXISTING 4" SQ W/SG & COVER BY E( EXISTING EXISTING EXISTING BY OTHERS SURFACE MOUNT 8.125 X 6.125 X 4 BY OTHERS BY EC EXISTING BY EC DESK OR STAND DESK OR STAND 6G BY EC 6G BY EC 20.75 X 25.75 X 6.75 52.125 X 25.75 X 6.75 13.5"H x 16.25"W x 4.25"D (2) 52.125 X 25.75 X 6.75 22 X 24 X 6.9375 FIR2021-0126 N 0 I 0 0 I Q LL_ �`�1 4A O O C O V O O a� U) o00 o00 IZI- IZI- Ln = =$ �L 0 0 N N N 00 (3) p (D (D (.O Z3= o00 c:00 NNN CD CD a rx 4k co 0 0 CY3 0 � CY3 0 It C cq co 0 w 0 to O per+, p, C�2 0 CID � 0 CID � 0 CID m co a w w a pa F CGo ca M M M rn A z E- F c7 A a A A 0 a E cn a a a A A 0 w cU ca U 5 w L a U2 w a x F � a a w z 0 1 F U ao 0 w w 0 w .M-I .�-i �-i A Cz\2 134 O ao I co I ao I rn E A o 0 CQ co C\2 I e� � �, o) o Z w 0) 0 DRAWINGS REVIEWED BY. Chad McCammon, SET NICET #090810,�z1ti Fire Alarm Systems, Level IV U) n� W Q 0 I� W W F-1 W �4 [� Q w W co W �I w z w W Q CO 0 z C cCD o2 CN o N W APPROVED BY: S.R.B. DRAWN BY: RECEIVED G.O.K. Nov 16 2021 TY F EDM ND DATE: DEVELOPMENT SERVICES 8-1-94 DEPARTMENT PROJECT NUMBER: 458-90031 SHEET NUMBER: FA-COV-02 LOWVWPLiT I SLC LINES ID ® m B TR FROM PREVIOUS DEVICE OR FAC.P. ICI TYPICAL ADDRESSABLE WIRING DIAGRAM m m WLLY CLOSED (N.C.) MON NORMALLY OPEN (N.O.) ILMDN YCLOSED (N.C.) MALLY OPEN (N.O.) oPDONAL SHIELD m s °IV COMMON CLOSED (N.C.) Y OPEN (N.O.) Y CLOSED (N.C.) Y OPEN (N.O.) 0 0 ADDRESS SEmND UNDER TYPICAL l A M RE -SEALABLE LABEL SECONDARY IDNet/MAPNEr II LINES WIRING DIAGRAM m m M u SHIELD TO NEXT ADDRESSABLE DEVICE IDNET+ I I I 1IDNET- TYPICAL HEAT DETECTOR WIRING DIAGRAM SENSOR 4098-9733 W 501 � ME X=1 WEST PENN #D975 #18AWG L� TYPICAL E90 (s.l40_-W W) CEILING SPEAKER STROBE \ WIRING DIAGRAM B v9 8 8 Ci= (2) #14 AWG REAR VIEW FRONK MEW TO EXISTING SPEAKER CIRCUIT TO NEXT DEVICE OR 1OK OHM EOL RESISTOR SENSOR 4098-9733 E-Ii ool TO EXISTING SPEAKER CIRCUIT 2098-9806 REMOTE ALARM INDICATOR/ KEYSWITCH RED RED ALARM LED -- - - r TEST R=4 #16 AWG X=1 WEST PENN #D975 #18AWG TYPICAL DUCT DETECTOR WIRING DIAGRAM 4098-9756 4—WIRE DUCT SENSOR SW2 1L>D z 201= 300= 4=� 5 L10 691= 700= 8=� ADDRESS SWITCH 161 1 2 3 4 5 6 7 8 ®® 11 12 13 14 15 1e + - AP MAP - + - LED TEST +24V 24C ALM POWER + TO FACP 24VDC POWER SUPPLY POWER - TYPICAL SPEAKER WIRING DIAGRAM P=2 #14 AWG 2098-9806 REMOTE ALARM INDICATOR/ KEYSWITCH RED RED ALARM LED _... k TEST =4 #16 AWG P=2 #14 AWG F= 2 #1//��4 /AWG WHT VV1.1TP 7� - BLU_C 4098-9843 YEL N.C. PAM-SD — RELAY ORG—N.O. RED RED ��— TYPICAL SPEAKER WIRING DIAGRAM 1 2 W 1OK EOL SISTOR 4081-9008 TYPICAL DUCT DETECTOR WIRING DIAGRAM 4098-9756 4—WIRE DUCT SENSOR SW2 1UM= z 2 L>D 301E= 4L7 501= 6L>o 7 01= SLR ADDRESS SWITCH T61 1 2 3 4 5 6 7 8 ®® 11 12 13 + - AP + MAP - LED TEST I I I I I 24V 241 ALM ArRLI TO NEXT ADDRESSABLE DEVICE MAPNET + F=2 #114 /AWG WHT W.{Tp_Tm__ - BLU_C 4098-9843 YEL N.C. PAM-SD — RELAY ORG—N.O. RED RED- 1 2 W 10K EOL SISTOR 4081-9008 TYPICAL SIGNAL ZAM (-) ` K=2 TW/SHLD PR. #16 AWG ` K=2 TW/SHLD PR. #16 AWG WIRING DIAGRAM Fow + .slll°°s:li>» 1 FF SIGNAL ZAM 10 NACI NAC 2 K 3 NA: 4 6 1 O 1 * � i SHIELD 0 0 0 0 0 0 0 0 0P�o 0 8 8 =l ll'si lliii� 8 8 '�i:ieeeii-lll;lr NY -AY +AY -AY AY a I IN . .. I I TB4 SIGNAL MAPNET- [ CIRCUIT OUT + MAPNET IN HARDWARE ADDRESS/ () # MAPNET+ C= 2 14 AWG REAR VIEW FRONT HEW C= () # 2 14 AWG REAR VIEW FRONT VIEW r L CONFIG SOFTWARE + 0 V[ TO 4120 MINIPLEX TO NEXT DEVICE +28V TRANSPONDER 1 OR 10K OHM SIGNAL # EOL RESISTOR CIRCUIT IN 1 P=2 #14 AWG ° TYPICAL STROBE TYPICAL STROBE TO FACP 24wTBsC WIRING DIAGRAM WIRING DIAGRAM POWER SUPPLY ° ° TO EXISTING IN + �SPEAKER OUT + CIRCUIT IN - NAC + NAC + OUT - NAC - NAC - T65 8p1OK 4904 SERIES 4904 SERIES 4009-9201 12 0 IDNet NAC PANEL 0 0 ° � ADDRESSABLE NAC SYSTEM FIRE FIRE o o ASSY 0565-771 A B C D =2 TW/SHLD PR. #16 AWG��=2 TW/SHLD PR. #16 AWG TYPICAL SMOKE DETECTOR WIRING DIAGRAM SENSOR SENSOR 4098-9714 4098-9714 X=1 WEST PENN #D975 #18AWG 0® ® 0 �® ® 0 +I I I I �I +I I I I (I SHLD TO NEXT DEVICE SHLD TO TPR #1 V-L Jr.- /-"111V V-L Jr.- -"- TYPICAL POINT TO POINT WIRING DIAGRAM SCALE. • NONE FIR2021-0126 Vf CO O� C C � O V O O O U, 000 000 ,;I_1tL0 0 �00 NNN 73'- 000 NCO (NNN Q co C) CN OLo rn U) U) U) fs, O Lo O O CID .4 Co O j Nt d' d' Goo p0.+, a N � Lo � Lo o� co O o x w z w x E i t%l C172 172 z O � F A a A A E v a a A A O W z p 0 y, 0 W 5 U r w a E a W � z a' O t%] E U O O ra w 0 w A a W CD I co I Co I CA I 02 d A 02 co CI) Lo M .1 CA O z 0 1-4 02 DRAWINGS REVIEWED BY. Chad McCammon, SET NICET #090810� Fire Alarm Systems, Level IV di Q I� W W z W- I I� V�1I w LU z w Q Q I� W N ~ W W r__ z CD 2E Q w APPROVED BY: S.R.B. DRAWN BY: RECEIVE G.O.K. DATE: CITY OF EDMONDS DEVELOPMENT SERVICES 8 — 1 — 9 4 DEPARTMENT PROJECT NUMBER: 458-90031 SHEET NUMBER: FA—DET-02 J ------------- 1 K 14 3-13 P TO 28 PRE -ACTION PANEL M1-30 F D 1 DR PX K X F TO FAN SHUTDOWN I � 3-14 1 DKX DKX 29 I F EXISTING MECHANICAL ROOM #6 EA ZONE BASEMENT. M x L DN TO TEL. RM SUB —BASEMENT FIRE ALARM DEMO PLAN SCALE: 1/8" = 1'-0" 0 RS AREA OF WORK GENERAL NOTES: 1. EXISTING INFORMATION IS SHOWN LIGHT AND BASED ON INFORMATION PROVIDED BY OTHERS. FIELD VERIFY ALL EXISTING EQUIPMENT AND CONNECTIONS AS NEEDED. 2. TAP SPEAKERS AT 1 /2w 25v, UNLESS OTHERWISE INDICATED ON DRAWINGS. FIELD VERIFY SPEAKER VOLTAGE AND CONNECTIONS BEFORE INSTALATION. REVISION 20 FLAG NOTES: 20 1 EXISTING DEVICE TO BE REMOVED AND RETURNED TO OWNER. REMOVE ANY UN —NEEDED WIRING AND MAINTAIN CIRCUIT INTEGRITY. FIR2021-0126 CO O� Mims C O U O mm%o CD U) o00 CDCDC:) 0 �00 NNN 73', o00 �00 N N N Q c� � N CD Ln N di W C7) U) U) U) Ey 0 0 0 CID .., 00 cr) CQ W LID qqtp0+, d' d' a O a cy to � co 0 co c00 CD O LO CID a w z w a A z O F a a A A � U Ey M a a a a A q' O W z O 0 V) O U U a w w � z x 0 P-4 E- o 0 w 04 P w 0 w A N o w02 00 ' 0 03 A 0 LID I am LID 0)� O z 0 DRAWINGS REVIEWED BY. Chad McCammon, SET NICET#090810 Uj Fire Alarm Systems, Level IV a di Q z 0 Q W W z E.. di Z a � W N w di 0 � � Q W ~ Lu w W z z W w Q W Q = v� ~ o di W � z CD CN o N W APPROVED BY: S.R.B. DRAWN BY: RECEIVED G.O.K. Nov 16 2021 CITY OF EDMONDS DATE: DEVELOPMENT SERVICES DEPARTMENT 8-1-94 PROJECT NUMBER: 458-90031 SHEET NUMBER: FA-B-01D MEN ------- SEE ---MEN 1 K 14 3-13 P TO 28 PRE -ACTION PANEL M1-30 F D 1 DR PX KX F TO FAN SHUTDOWN I � 3-14 1 DKX I DK� 28 I F 1 I 111 I EXISTING MECHANICAL ROOM #6 MEN — EA ZONE BASEMENT. I L DN TO TEL. RM I MEN — �MATCHLINE I 1 -- K28 O LSD; 1 E EJX 1 I I KX 3-41 .� K F yI I CONTRACTORS AREA OF WORK 28 I EJX I 1 I I 1 rtiALL� 'I '1 2 r-� 1� L-J 40 I 1 I CEJX KX A 3-42 K GENERAL NOTES: F 1 1. EXISTING INFORMATION IS SHOWN LIGHT 8 AND BASED ON INFORMATION PROVIDED BY OTHERS. FIELD VERIFY ALL EXISTING EQUIPMENT AND CONNECTIONS AS _ NEEDED. 2. TAP SPEAKERS AT 1 /2w 25v, UNLESS OTHERWISE INDICATED ON DRAWINGS. 1 FIELD VERIFY SPEAKER VOLTAGE AND CEJX CONNECTIONS BEFORE INSTALATION. REVISION 20 FLAG NOTES: 20 1 EXISTING DEVICE TO BE REMOVED AND RETURNED TO OWNER. REMOVE ANY UN —NEEDED WIRING AND MAINTAIN CIRCUIT INTEGRITY. 1 K I F I28 1 MEN MEN MEN MEN MEN MEN MEN MEN ME IN SUB - BA SEMEN T FIRE ALARM FLOOR PLAN SCALE: 1/8" = 1'-0" 0 FIR2021-0126 CHAN E-FIR E-FIR E-FIR E-FIR E-FIR E-FIR E-FIR E-FIR CO O Mims C O U O mm%o CD U) 000 CDCDC:) 0 �00 NNN 73', o00 �00 N N N Q c� o� � � N CD Ln N di W C7) U) U) U) Ey 0 CD 0 0 0 CID .., 00 cr) CQ W LID q1tpO+y d' d' a O a cy to � co 0 co c00 CD O LO CID a w z a A Z O F lit A a A A U Ey a a A A' O W z O 0 V) O U U 5 u u) w a w w z x O P-4 E- IL) o O r= t�� 04 i�� p4 G4 O fa A Cz�2 O 00 0 03 E A 0 LID 02 to I am LID 0) O Z 00 0 0 CQ DRAWINGS REVIEWED BY. Chad McCammon, SET NICET#090810 Fire Alarm Systems, Level IV V 1 a di 0� Q z 0 H W W z E.. di Z 1.4 a � W NN 0 � � Q W ~ Lu w Z W Z) z W w Q W Q = v� ~ o di W � z CD CN o N W APPROVED BY: S.R.B. DRAWN BY: RECEIVED G.O.K. Nov 16 2021 CITY OF EDMONDS DATE: DEVELOPMENT SERVICES DEPARTMENT 8-1-94 PROJECT NUMBER: 458-90031 SHEET NUMBER: FA-B-01