Loading...
REVIEWED BLD RESUB1 BLD2021-1434+MISC INFO+11.22.2021_2.46.50_PM+2533705Lntortok Code Compliance Research Report Total Quality. Assured. CC R R-0101 DIVISION: 06 00 00 — WOOD, PLASTICS, AND COMPOSITES Section: 06 50 00 — Structural Plastics Section: 06 53 00 — Plastic Decking REPORT HOLDER: The AZEK® Company LLC 894 Prairie Avenue Wilmington, OH 45177 www.azekco.com REPORT SUBJECT: AZEK ARBOR Collection® AZEK Harvest Collection® AZEK Porch Boards AZEK Vintage Collection® AZEK MAX 1.0 SCOPE OF EVALUATION 1.1 This Research Report addresses compliance with the following Codes: 2018, 2015, 2012 International Building Code® (IBC) 2018, 2015, 2012 International Residential Code' (I RC) 2017 Florida Building Code (FBC), excluding High - Velocity -Hurricane Zones (HVHZ) (See Section 9.0) NOTE: This report references 2018 Code sections with [2015] Code sections shown in brackets where they differ. FBC Code sections match IBC 2015 code sections. 1.2 AZEK Decking (Deck and Porch Boards) have been evaluated for the following properties: Structural Performance Durability Surface Burning Issue Date: 07-28-2005 Revision Date: 07-27-2020 Renewal Date: 05-31-2021 1.3 AZEK Decking (Deck and Porch Boards) are intended for use as a walking surface on exterior decks, balconies, porches, and walkways, including stairs in One- and Two - Family Dwellings regulated by the IRC and other construction types regulated by the IBC in accordance with IBC Section 705.2.3 Combustible projections [1406.3], where fire -resistance rated floor construction is not required for the deck or balcony. 2.0 STATEMENT OF COMPLIANCE AZEK Decking (Deck and Porch Boards) comply with the Codes listed in Section 1.1, for the properties stated in Section 1.2 and uses stated in Section 1.3, when installed as described in this report, including the Conditions of Use stated in Section 6. 3.0 DESCRIPTION 3.1 Materials and Processes - AZEK Decking are composed of a solid co -extruded cellular polyvinyl chloride (PVC) with a polymer cap. Harvest and Arbor collections are semi - capped (capped on three sides), and the Vintage collection is fully capped in cross section. 3.2 AZEKPorch Boards measure 1" thick with a 3.2" exposure width (3.415" overall width) and 5.5" exposure width (5.715" overall width) and are produced in five colors: Brownstone, Coastline, Dark Hickory, Mahogany, Morado®, Silver Oak®, Oyster®, and Slate Gray. 3.3 The 5.5" wide AZEK Decking measure 1" thick and are provided in the following collections: 3.3.1. AZEKHarvest® Collection®deck boards are produced in five colors: Autumn ChestnutTM, Brownstone, Island OakT" Kona®, and Slate Gray. 3.3.2. AZEK ARBOR Collection® deck boards are produced in six colors: Acacia®, Brazilian Walnut, Hazelwood, Morado®, Mountain Redwood T"°, and Silver Oak®. ETA545 E. Algonquin Road • Arlington Heights * Illinois • 60005 ACCREDITEV =1 .,. Intertek intertek.com/building PCA-101 Version: 6 April 2017 SFT-CCRR-OP-40b `� ' Code Compliance Research Report CCRR-0101 Page 2 of 11 3.3.3. AZEK Vintage Collection® deck boards are produced in 5.0 INSTALLATION six colors: Coastline, Cypress, Dark Hickory, English Walnut, Mahogany, and Weathered Teak. Installation shall be in accordance with the manufacturer's installation instructions and this report. Where differences 3.4 The 3.5" and 7.25" wide AZEK Decking measure 1" thick occur between this report and the manufacturer's installation and are provided in the following collections: instructions, this report shall govern. 3.4.1. AZEK Vintage Collection® products are produced in three colors: Cypress, Dark Hickory, and Mahogany. 3.4.2. AZEK Harvest Collection® products are produced in two colors: Brownstone and Slate Gray. 3.5 The AZEK MAX decking measures 1.5" thick by 5.5" wide and are provided in the following colors: Coastline and Slate Gray. 3.6 The walking surface is embossed with a simulated wood grain. 4.0 PERFORMANCE CHARACTERISTICS 5.1 AZEK Decking shall be installed with fastening as indicated in Table 1. 5.2 AZEK porch boards used as stair treads shall be installed as shown in Figure 5. 5.3 AZEK deck boards used as stair treads shall be installed as shown in Figures 5, 6, and 7. See Table 2 for maximum stair tread spans. 5.4 AZEK Deck and porch may be installed diagonal to support framing up to maximum of 45° with 12" o.c. maximum joist spacing. 6.0 CONDITIONS OF USE 4.1 AZEK Decking are rated for a uniform live load of 100 Ibs/ftz when installed on support framing spaced at 16" on The AZEK Decking applications identified in this report are center. This live load rating also applies to deck boards and deemed to comply with the intent of the provisions of the porch boards installed diagonal to the support framing (45° referenced building codes subject to the following conditions. max.) with 12" on center maximum joist spacing. 4.2 AZEK Deck and porch boards used as stair treads shall be installed on a minimum of a two -span condition and are rated for the code -prescribed concentrated load equal to 300 Ibs when installed in accordance with Table 2. 4.3 AZEK Decking has wind uplift resistance ratings as indicated in Table 1 when installed on support framing spaced at 16 inches on center. 4.4 AZEK Decking is deemed equivalent to preservative treated or naturally durable wood for resistance to weathering effects, attack from termites and fungus decay. 4.5 AZEK Decking structural performance has been demonstrated for a temperature range of -20' F to 125° F. 4.6 AZEK Decking has a flame spread index not exceeding 200 when tested in accordance with ASTM E 84. 6.1 The wind uplift resistance rating recognized in this report is based on attachment to treated Southern Pine framing (specific gravity, G=0.55). Installation on wood framing with a lesser specific gravity may result in a lower wind uplift rating. 6.2 AZEK Decking shall be fastened directly to supporting construction. Conventional wood supporting structure is not within the scope of this report and is subject to the evaluation and approval by the building official. Design and construction of supporting structure must satisfy the design load requirements of Chapter 16 of the IBC. ETA545 E. Algonquin Road • Arlington Heights * Illinois • 60005 ACCREDITEV =1 .,. Intertek intertek.com/buildine PCA-,o, Version: 6 April 2017 SFT-CCRR-OP-40b ton Code Compliance Research Report CCRR-0101 6.3 Where required by the building official, engineering calculations and details shall be provided. The calculations shall verify that the anchorage complies with the building code for the type of framing and condition of the supporting construction. 6.4 The compatibility of all fasteners with supporting structure, including chemically treated wood, is not within the scope of this report and subject to approval by the code official. 6.5 AZEK Decking recognized in this report are manufactured in accordance with the manufacturer's approved quality control system with inspections by Intertek. 7.0 SUPPORTING EVIDENCE 7.1 Manufacturer's drawings and installation instructions. 7.2 Reports of testing demonstrating compliance with ICC-ES AC174, Acceptance Criteria for Deck Board Span Ratings and Guardrail Systems (Guards and Handrails), revised December 2014 and ASTM D 7032-14 [10a]. 7.3 Documentation of an Intertek approved quality control system for the manufacturing of products recognized in this report. 8.0 IDENTIFICATION AZEK Decking produced in accordance with this report shall be identified with labeling on the individual deck boards that includes the following information: 8.1 Name and/or trademark of manufacturer. 8.2 The following statement: "ASTM D7032. See Intertek CCRR-0101 at https://whdirectory.intertek.com for uses and performance levels." Page 3 of 11 8.3 Packaging of deck boards shall also be identified with the Intertek identification mark and Code Compliance Research Report number (CCRR-0101) as shown: CODE COMPLIANCE ETA Intertek CCRR-0101 9.0 OTHER CODES 9.1 Scope of Evaluation: AZEK Decking was evaluated for compliance with the Florida Building Code — Building and Florida Building Code — Residential. 9.2 Conclusion: AZEK Decking, described in Sections 2.0 through 7.0 of this Research Report, comply with the Florida Building Code — Building and Florida Building Code — Residential, subject to the following conditions: Use of AZEK Decking for compliance with the High - Velocity Hurricane Zone provisions of the Florida Building Code — Building and the Florida Building Code — Residential has not been evaluated and is outside the scope of this Research Report. Intertek is an approved evaluation entity and quality assurance entity pursuant to Florida Statute 553.842 — Product Evaluation and Approval. ETA545 E. Algonquin Road • Arlington Heights * Illinois • 60005 ACCREDITEV =1 .,. Intertek intertek.com/building PCA-101 Version: 6 April 2017 SFT-CCRR-OP-40b ton Code Compliance Research Report CCRR-0101 10.0 CODE COMPLIANCE RESEARCH REPORT USE 10.1 Approval of building products and/or materials can only be granted by a building official having legal authority in the specific jurisdiction where approval is sought. 10.2 Code Compliance Research Reports shall not be used in any manner that implies an endorsement of the product by Intertek. 10.3 Reference to the https://bpdirectorV.intertek.com is recommended to ascertain the current version and status of this report. Page 4 of 11 This Code Compliance Research Report ("Report') is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Report. Only the Client is authorized to permit copying or distribution of this Report and then only in its entirety, and the Client shall not use the Report in a misleading manner. Client further agrees and understands that reliance upon the Report is limited to the representations made therein. The Report is not an endorsement or recommendation for use of the subject and/or product described herein. This Report is not the Intertek Listing Report covering the subject product and utilized for Intertek Certification and this Report does not represent authorization for the use of any Intertek certification marks. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. ETAWA 545 E. Algonquin Road • Arlington Heights * Illinois • 60005 ACCREDITED Intertek intertek.com/buildine PCA-,o, Version: 6 April 2017 SFT-CCRR-OP-40b ton Code Compliance Research Report CCRR-0101 Table 1— Fastening Schedule and Wind Rating Page 5 of 11 Product Fastening Description Span Wind Uplift Resistance (1) #8 x 2-1/2" stainless steel trim -head Headcote"" screw @ 45' through 3.2 inch AZEK Porch root of tongue into each joist 16" o.c. 294 psf Board (1) 16 GA x 2" Simpson Strong -Tie L Series Stainless Steel Flooring Cleat at 45' through root of tongue into each joist 16" o.c. 102 psf (1) #10 x 2-1/2" stainless steel trim -head Headcote'' screw @ 45' through root of tongue into each joist 16" o.c. 144 psf 5.5 inch AZEK Porch (1) #10 x 2-1/2" TOPLoc"" stainless steel screw into each joist 16" o.c. 177 psf Board (1) OMG FastenMaster° Cortex concealed fasteners each joist (#10 x 2- 1/2" screws) 16" o.c. 158 psf 3.5 inch AZEK (2) #10 x 2-1/2" TOPLoc''stainless steel screw into each joist 16" o.c. 631 psf Harvest® Collection® 3.5 inch AZEK (2) OMG FastenMaster° Cortex concealed fasteners each joist (#10 x 2- ARBOR Collection' 3/4" screws) 16" o.c. 631 psf 3.5 inch AZEK Vintage Collection® (2) SIDELoc'"' hidden fasteners per joist (#8 x 1-7/8" screws) 16" o.c. 316 psf (2) #8 x 2-1/2" stainless steel trim -head Headcote'"' screw into each joist 16" o.c. 351 psf (2) #10 x 2-1/2" TOPLoc'"'stainless steel screw into each joist 16" o.c. 593 psf (2) OMG FastenMaster° Cortex concealed fasteners each joist (#8 x 2-3/4" screws) 16" o.c. 486 psf 5.5 inch AZEK CONCEALoc'' Hidden Deck fastener with 1-1/2" pneumatic screws. Harvest® Collection® Starter board (edge) face -fastened with (1) #8 x 2-1/2" stainless steel trim- 16" o.c. 135 psf 5.5 inch AZEK head Headcote"" screw ARBOR Collection® HlDfast hidden fastener (13 GA x 2-1/2") with (1) #8 x 2-1/2" stainless 5.5 inch AZEK steel trim -head HeadcoteTm screw at each joist for the starter (edge) 16 o.c. 119 psf Vintage Collection® board. FUSIONLoc' Hidden Deck fastener with 2" pneumatic screws. Starter board (edge) face -fastened with (1) #8 x 2-1/2" stainless steel trim -head 16" o.c. 186 psf Headcote' screw EdgeFast hidden fastener (14 GA x 2-1/4" long) installed through the groove of the board and into each joist at 45° 16" O.C. 146 psf ETA545 E. Algonquin Road • Arlington Heights a Illinois • 60005 ACCREDITEV =1 .,. Intertek intertek.com/building PCA-101 Version: 6 April 2017 SFT-CCRR-OP-40b ton Code Compliance Research Report CCRR-0101 Page 6 of 11 Product Fastening Description Span Wind Uplift Resistance 7.25 inchAZEK (2) #10 x 2-1/2" TOPLocl stainless steel screw into each joist 16" o.c. 454 psf Harvest® Collection® (2) OMG FastenMaster° Cortex concealed fasteners each joist (#10 x 2- 7.25 inch AZEK 3/4" screws) 16" o.c. 372 psf Vintage Collection® (2) SIDELocTm hidden fasteners per joist (#8 x 1-7/8" screws) 16" o.c. 163 psf (2) SIDELocTm hidden fasteners perjoist (#8 x 2-3/8 inch, 9 TPI, 0.42 inch long reverse pitch, 0.162 inch major dia., 0.120 inch shank dia., 0.199 inch head 24" o.c. 162 psf dia., type 17 point screws) (2) OMG FastenMaster® Cortex® concealed fasteners each joist (#10x2- 1/2", 12 TPI, 0.55 inch long reverse pitch, 0.191 inch major dia., 0.150 inch 24" o.c. 273 psf shank dia., 0.262 inch head dia., type 17 point screws) (2) OMG FastenMaster° Cortex® concealed fasteners each joist (#10 x 2- 3/4", 12 TPI, 0.50 inch long reverse pitch, 0.191 inch major dia., 0.150 inch 24" o.c. 341 psf shank dia., 0.262 inch head dia., type A point screws) AZEK MAX (2) #10 x 2-1/2" TOPLocl stainless steel screw into each joist (12 TPI, 0.182 inch major dia., 0.132 inch shank dia., 0.265 inch head dia., type 17 point 24" o.c. 260 psf screws) (2) #10 x 3" OMG FastenMaster® TrapEase03 stainless steel screws into each joist (12 TPI, 0.50 inch long reverse pitch, 0.195 inch major dia., 0.156 24" o.c. 417 psf inch shank dia., 0.257 inch head dia., type 17 point screws) (2) #10 x 2-1/2" OMG Fasten Master' TrapEase®3 stainless steel screws into each joist (12 TPI, 0.45 inch long reverse pitch, 0.195 inch major dia., 0.156 24" o.c. 278 psf inch shank dia., 0.257 inch head dia., type 17 point screws) ETA545 E. Algonquin Road • Arlington Heights * Illinois • 60005 ACCREDITEV =1 .,. Intertek intertek.com/buildine PCA-,o, Version: 6 April 2017 SFT-CCRR-OP-40b `� ' Code Compliance Research Report CCRR-0101 Table 2 — Stair Tread Span Ratings Page 7 of 11 Maximum Product Stair Tread Installation Span 3.2" AZEK Porch Board 11" See Figure 5 for installation details. 5.5" AZEK Porch Board 10" See Figure 5 for installation details. 5.5" AZEK Harvest® Collection® 5.5"AZEK ARBOR Collection® 17.25" 2X6 additional supports. See Figure 6 for installation details. 5.5"AZEK Vintage Collection® 24" 2X4 additional supports. See Figure 7 for installation details. 7.25" AZEK Harvest® Collection® 7.25" AZEK Vintage Collection® 12" See Figure 5 for installation details. AZEK MAX 14" See Figure 5 for installation details. 215' .332" .985'': 332" 3.415" 3.2 inch Porch Board Figure 1— AZEK Porch Board _215" ,332" 332" 5.715" 5.5 inch Porch Board ETA545 E. Algonquin Road • Arlington Heights a Illinois • 60005 ACCREDITED' Intertek intertek.com/building PCA-101 Version: 6 April 2017 SFT-CCRR-OP-40b ton Code Compliance Research Report CCRR-0101 1 x 5-%: Solid Deck Board 3.5" 1.0" 1 x 3-1/2 Solid Deck Board ETA Intertek 1 " i .21 Y r� 1 x 5-%: Grooved Deck Board 1 x 7-1/4 Solid Deck Board Figure 2—AZEKArbor, Harvest, and Vintage Decking 5.55" - Figure 3 — AZEK MAX Decking 545 E. Algonquin Road • Arlington Heights * Illinois • 60005 intertek.com/building Page 8 of 11 ACCREDITED' PCA-101 Version: 6 April 2017 SFT-CCRR-OP-40b Lon ETA Intertek Version: 6 April 2017 Code Compliance Research Report CCRR-0101 FastenMasterO Cortex TOPLocTm Face Fastener CONCEALoc' Hidden Fastener Figure 4 — Fasteners HidFast Fastener EdgeFastFastener FusionLocr' Hidden Fastener Page 9 of 11 545 E. Algonquin Road • Arlington Heights * Illinois • 60005 ACCREDITED' intertek.comintertek.com/building PCA-101 SFT-CCRR-OP-40b ton ETA Intertek Code Compliance Research Report CCRR-0101 AZEK DECKW IS ATTACHED TO EACH STRNGER. SEE BELOW FOR FASTENNG. MAX SPAN Figure 5 — Stair Tread Installation with no additional support (Minimum tread length is 36") ATTACH 2X6 TREATED SO. PINE IN CENTER OF EACH TREAD AS SHOWN USING A SIMPSON A23 BRACKET AND 1 Od X 1-1 f2" AZEK DECKING IS ATTACHED TO STRINGERS USING TWO (2) #8 X 2-1 f2" k FLATHEAD WOOD SCREWS PER k STRINGER 17.25" .A MAX 3611 Figure 6 — Alternate 1 X 5-%: Stair Tread Installation for 17.25" Span (2X6 additional support) 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building Page 10 of 11 ACCREDITED' PCA-101 Version: 6 April 2017 SFT-CCRR-OP-40b ton ETA Intertek Code Compliance Research Report CCRR-0101 ATTACH TREATED SO. PINE 2X4 SUPPORT UNDER EACH TREAD AS SHaV%N USING TWO (2) 0.131" DIA X 3-114" LONG ROUND DRIVE FRAMING NAILS Version: 6 April 2017 7.500" NAIL (TYP) IN LOCATION SHOWN AZEK 1 X6 DEC KBOARD (v 4.125" 1 .875" 24.00" MAX 49.50" Page 11 of 11 A.ZEK DECKING IS ATTACHED TO STRINGERS USING TWO #7 X 2-1 A" LONG TRIM HEAD SCREWS (SWAN SECURES'S SCRUDINI OR EQUAL) Figure 7 — Alternate 1 X 5-% Stair Tread Installation for 24" Span (2X4 additional supports) 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 ACCREDITED' intertek.com/building PCA-101 SFT-CCRR-OP-40b