APPROVED BLD PLN BLD2021-1705+Site_Plan+12.15.2021_12.06.49_PM+2574653A
C
u
MITSUBISHI ELECTRIC TRANE HVAC US: CITY MULTI VRF OUTDOOR UNIT SCHEDULE
L
F
G
J
L I M I N
2
3
4
5
System Tag
Tag Reference
M-Net Address
Model Number
Modules
Nominal Cooling
Capacity (BTU/h)
Nominal Heating
Capacity (BTU/h)
Cooling
Efficiency
IEER/EER
[SEER]
Heating COP @
47°F [HSPF]
Nom System
Connected
Capacity (% of
NOM)
Design Cooling
Outdoor Temp
DB (°F)
Design Heating
Outdoor Temp
WB (°F)
Refrig Pipe Dim
High/Low
Pressure (inch)
(See Note 4)
Corrected
Cooling Total
Capacity (BTU/h)
Corrected
Heating Capacity
(BTU/h)
Sound Pressure
(dBA)
Electrical -Per Module
Notes /Options
208/230 or [460V]
Voltage /Phase
MCA 208/230 or
[460V]
RFS
MOCP
System 1
CU-1
N/A
MUZ-GL09NA-U1
9,000.0
10,900.0
[24.60000038146
97]
[12.8]
100.0%
85.0
20.2
1/4 / 3/8
8,894.3
9,061.8
48/50
208/230V / 1-
phase
9
15
15
1, 2, 3, 4, 5
Notes &Options:
1 Nominal cooling capacities are based on indoor coil EAT of 80/67°F (DB/WB), outdoor of 95°F (DB)
2 Nominal heating capacities are based on indoor coil EAT of 70°F (DB), outdoor of 43°F (WB)
3 Efficiency values for EER, IEER, COP are based on AHRI 1230 test method for mixture of ducted &non -ducted indoor units.
4 For systems with multiple modules, refigerant pipe dimensions indicate total system combined piping downstream of module twinning.
5 Added field charge listed is in addition to factory charge, this must be updated based upon final as -built piping layout.
MITSUBISHI ELECTRIC TRANE HVAC US: CITY MULTI VRF INDOOR UNIT SCHEDULE
SCOPE OF WORK:
FOR THE PURPOSE OF ELEVATOR MODERNIZATION:
INSTALL SPLIT UNIT AIR CONDITIONING FOR THE EXISTING ELEVATOR
MACHINE ROOM. SIZE THE UNIT FOR PROPER COOLING AND AS STATED
ON THE EQUIPMENT SCHEDULE. INSTALL CONDENSER UNIT EQUIPMENT
WALL MOUNTED IN THE PLANTER ON THE BACK OF THE GARAGE WALL
PER THIS PLAN. ENERGY CODE ECONOMIZER C403.5 EXCEPTION 11
TAKEN.
MECHANICAL CODE: 2018
Cooling Design
Entering Temp
Heating Design
Entering Temp
Corrected Capacity
Refrig Pipe Dim
Peak Fan Airflow
Max Fan ESP
Setting
Sound Pressure
Per Fan Speed
Cooling Diversity
Heating Diversity
Nominal Cooling
Nominal Heating
DB/WB (°F) /
DB/WB (°F) /
Full/Partial (See
Cooling Total
Cooling Sensible
Full/Partial (See
Heating Capacity
Liquid/Suction
(cfm) / [Design
208V/230V (IN
208V/230V
Power Cooling
Power Heating
Electrical
System Tag
Room Name
Tag Reference
Model
Type
Capacity (BTU/h)
Capacity (BTU/h)
[Water in temp]
[Water in temp]
Note 5, 6)
Capacity (BTU/h)
Capacity (BTU/h)
Note 5, 6)
(BTU/h)
(inch)
gpm G(US)/min]
WG)
(dBA)
Voltage /Phase
208V/230V (kW)
208V/230V (kW)
MCA/MFS
Notes /Options
19-22-30-37-
Elevator Machine
43/19-22-30-37-
208/230V/1-
Powered by
System 1
Room
FU-1
MSZ-GL09NA-U1
Wall -Mounted
9,000.0
10,900.0
80.0/67.0
70.0
FULL DEMAND
8,894.3
7,968.4
FULL DEMAND
9,061.8
3/8 / 1/4
406
43
phase
Outdoor
1, 2, 3, 4, 5, 6
MATCH LINE
O BTAI
PEI
STA
IN
6 I I ALL W(
T
INSPE
CODE �
AP
' PLAN
NJ
10
Notes &Options:
1 Nominal cooling capacities are based on indoor coil EAT of 80/67°F (DB/WB), outdoor of 95°F (DB)
2 Nominal heating capacities are based on indoor coil EAT of 70°F (DB), outdoor of 43°F (WB)
3 See outdoor unit schedule for outdoor ambient conditions, connected capacity, and other factors associated with corrected capacities
4 See schematic piping/control diagram for indication of required indoor unit remote controllers, system controllers, and integration devices.
5 Full demand corrected capacity includes de -rate associated with indoor vs. outdoor connected capacity indicated on outdoor unit schedule for associated system. Partial corrected capacity assumes sufficient diversity exists such that the connected capacity de -rate does not apply. It is the designer's responsibility to ensure "Diamond System Builder" is set in
the appropriate output capacity setting (full demand/partial demand) prior to generating this schedule.
6 It is recommended to always base heating corrected capacity on full demand.
ELECTRICAL
JI IT F F��,�
LABOR &
JSTRIES
GARAGE
K SUBJECT
OMPLIANCE
ROVED
MUST BE
OB SITE
LOWER LEVEL
SCALE: 1 /8" = 1'
KEY LEGEND
AND
COMPONENT
LIST
SYMBOL
DESCRIPTION
QTY
PART #
MANUFACTOR
MOUNTING SPEC
EXIST
NEW
CU-1
CONDENSER UNIT
�
MUZ-GL09NA-U1
MITSUBISHI
WALL MOUNT ROOF LEVEL
��
INDOOR FAN UNIT
�
MSZ-GL09NA-U1
MITSUBISHI
7' AFF TO BOTTOM
LI N E SET
18,
3/8" / 1 /4"
-
3/8" / 1 /4"
—
CONDENSATE DRAIN
- 18,
5/8"
TUBING
FROM FAN UNIT
CONDENSATE PUMP
�
554530
LITTLE GIANT
AT INDOOR FAN UNIT
2
APPROVED BY PLANNING
/C�,v'^'
Jan 05 2022
City Of Edmonds
Building Department
Work MECHNICAL
Address 200 JAMES ST- ELEVATOR
Owner EL CAPITAN CONDOS
Approved Date 12/27/2021
Building Official . Eriri L%a�rFer
Permit Number BLD2021-1705
OUTDOOR UNIT LOCATION
SCALE: NOT TO SCALE
4
[
ro
?
a n
�
Z
�
J"'
S2A � � ,aloha St
H
�
Slerra Pi �v
Cy��
h,3
Caral Way
sunset
:� then �St
Glen SC
¢�
- 1'� Beach
144`;
pak�'
�.
� Daley St naleyst
Daley St
2
� Spra�ue5t
,Cg
Sprague St
����
m
R
t`if
.`i'� Edmonds
i�_�J �
i'�
te$
4V�1
z
sell St
8ellsc
aeusc
5oearrJer
Tralrr S[aalaR 200 J�rn�s
--
aln St
M21r1 St
DayttSrt.t n � —�
in
� q
¢ Maple St
t
'eii
104
�� L
S
�r'pr
,�'� v
:a Alder St
k7'1
,�Iders�
ti{
+5�
Q-
Walnut St
Walnut St
_ �
Hol y I?r tedar St
°cy _
��+�
I
SprU C2 SQ
�aY
Hnrne4Bs�Ot S�YCU Ce St
_
d�<���
b
9 �.
¢ _ I
Hernlock Way Hemlock St
S
ll� ri n�
�°�tn � �,•�F '� Erben Dr
5eamnntLn Laurel St
� 5� 5 1
21 � t cV
�VICINTY MAP
SCALE: NOT TO SCALE
RECEIVED
Dec 16 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
a
z
O m
� �
> �
W F
� �
W
d
0
z
� o
w
rr
W N
F O
� N
0
0
��
C � ���
�� �Oc�o
J =
� � � N
0 6_ >�
C �1 � U � N
�� W �
J X
W O
m
0
o_
H
U
a
0
U
z
0
Q
N_
Z
zw
0
Q�wo
����
� o��
aa�
Qww�
vwao
��
o�
�°�o
J
Q
U
z
Q
w
w
0
_�
z
m
m
Q
W
W
a
z
W
Z
fA
W
APPROVED BY
ER
DRAWN BY:
ER
DATE:
12/10/21
JOB#
EL CAPITAN
DWG. NO.: M-01