FIR2022-0034+Fire_Alarm_Equipment_Specification_Sheets+3.31.2022_10.22.33_AM+2773145
TABLE OF CONTENTS 1. SCOPE OF WORK (1 PAGE) 2. SILENT KNIGHT 6S20 FIRE CONTROL (4 PAGES) 3. SILENT KNIGHT SS60 ANNUNCIATOR (Z PAGES) 4. AES 7707 COMMUNICATOR (4 PAGES) S. SILENT KNIGHT WSK-WGI GATEWAY (4 PAGES) 6. SILENT KNIGHT SK-PHOTO-W SMOKE DET (3 PAGES) 7. SILENT KNIGHT SK-HEAT-ROR-W HEAT DET (3 PAGES) S. SILENT KNIGHT S300-6 DETECTOR BASE (3 PAGES) 9. SILENT KNIGHT SK-MINIMON MONITOR (2 PAGES) 10. SILENT KNIGHT SK-PULL MANUAL (2 PAGES) 11. SILENT KNIGHT SK-RELAY (2 PAGES) 72. SILENT KNIGHT SWIFT WIRELESS AV (4 PAGES) 7.3. SYSTEM SENSOR STROBES AND HORNS (4 PAGES) 14. SYSTEM SENSOR OUTDOOR HIS (4 PAGES) 16d 11c RO BOX B04 VASH❑N WA, 9B❑7❑ SCOPE OF WORK EL CAPITAN CONDOS 200 JAMES STREET EDMONDS, WA 9BO20 OVERVIEW FOR THE PURPOSE OF ELEVATOR MODERNIZATION; INSTALL A NEW ADDRESSABLE FIRE ALARM PANEL AT THE EXISTING FIRE PANEL LOCATION. INSTALL A NEW ANNUNCIATOR IN THE BUILDING LOBBY. REPLACE ALL EXISTING INITIATING DEVICES WITH NEW, ADDRESSABLE DEVICES. INSTALL NEW NOTIFICATION APPLIANCES IN ALL COMMON AREAS, UNIT NOTIFICATION TO REMAIN UNCHANGED. INSTALL LOBBY AND MACHINE ROOM SMOKE DETECTION FOR ELEVATOR CONTROL. INSTALL RELAYS FOR ELEVATOR CONTROL. INSTALL MONITORING. CONTROL PANEL: THE EXISTING FIRE CONTROL PANEL IS FCI FC-72 CONVENTIONAL FIRE ALARM AND IS BEING REPLACED WITH A SILENT KNIGHT 6B20 ADDRESSABLE FIRE ALARM CONTROL WITH AES COMMUNICATOR. WIRING: ALL WIRING WILL BE FPLP OR BETTER RATED AND SIZED AS FOLLOWS: SLC CIRCUITS WILL BE AWG 16 OR GREATER INDICATING CIRCUITS WILL BE AWG 14 OR GREATER INSTALLATION: INSTALLATION WILL BE PERFORMED IN ACCORDANCE WITH NFPA 70, NFPA 72 AND APPLICABLE PROVISIONS OF THE WASHINGTON ADMINISTRATION CODE. TECHNICIANS FROM 16D, LLC, CERTIFIED BY THE STATE OF WASHINGTON AND UNDER PERMIT BY THE AUTHORITY HAVING JURISDICTION WILL PERFORM ALL INSTALLATION. TESTING AND WARRANTY: A COMPLETE TEST WILL BE PERFORMED IN THE PRESENCE OF THE OWNER, AND ANY OTHER AUTHORITY HAVING JURISDICTION DEEMED APPROPRIATE. FOLLOWING AN ACCEPTABLE TEST RESULT, THE OWNER AND 16D, LLC. WILL SET THE TERMS FOR WARRANTY SERVICE AND ARRANGE A CONFIDENCE TESTING SCHEDULE. 7 6D LLC WILL PROVIDE SYSTEMS TRAINING TO THE OWNER TO ENSURE PROPER OPERATIONS. Honeywell 5ILENT' KNIGHT Addressable Fire Alarm Control Panels Addressable Fire Alarm Control Panel The 6820 is an addressable fire alarm control panel (FACP) and is a direct replacement for the 5820XL FACP. The 6820 can be configured to achieve a point capacity of 1110 points and connect up to 17 panels in a single communications link. The 6820 has one built-in signaling line circuit (SLC), which can support 159 (SK) System Sensor' sensors and 159 SK modules or 127 (SD) Hochiki° devices per loop. To increase point capabilities, additional SLC loops can be added using the 6815 SLC expander for SK devices or the 5815XL expander for SD devices, increasing the point capacity to a maximum of 1110 points for SK devices and 635 points for SD devices. Three additional SLCs are needed to reach 1110 points (SK devices). Four additional SLCs are needed to reach 635 points (SD devices). A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single -point communications. It also has a built-in, dual - line POTS and IP communicator with additional cellular options available. The 6820 system can be enhanced by adding modules such as the 6860 remote annunciator which also has four programmable function buttons to help automate tasks and reduce time spent at the panel. SWIFT° wireless compatibility provides options forwireless detection through a Class A mesh network. It is ideal for hard -to -wire locations, buildings where newwiring is not allowed, or to provide an easy install fire system for new construction projects. SWIFT devices can be combined with other hard -wired 6820 compatible devices. FEATURES & B ENEFITS • Capable of providing up to 1110 points for enhanced design flexibility. Additional Signal Line Circuits can be added until maximum point levels are reached • Built-in USB interface for convenient and quick programming • Connect up to 17 panels on one site with convenient single - point access using the SK-NIC Network Interface Card. Connected panels can have mixed compatible FACP models • Convenient field-upgradeable firmware • Built-in dual path POTS and IP communications with optional cellular models available for reliable backup reporting • 6860annunciatorwith a 4 x 40 large display • JumpStart® auto programming reduces installation time 6820 The 6820 also has a form-C trouble relay, two programmable form-C relays, along with powerful features such as drift compensation, pre -trouble maintenance alert, a built-in sensor test to complywith NFPA 72 calibration testing requirements, and calibration trouble alert. The 6820 supports a variety of devices, including the 6860, 5860, and 6855 remote annunciators, 5824 serial parallel printer interface module (for printing system reports), the 5496 NAC expander, 5895XL power module, and SK or SD devices. • Programmable date setting for automatic and convenient Daylight Saving Time changes • Four user - programmable buttons minimize time spent executing complex or routine tasks • Flexput° circuits can be individually programmed to function as notification circuits, auxiliary power outputs, or initiating circuits that support both 2- and 4-wire smoke detectors SIGNAL LINE CIRCUIT (SLC) The 6815 signal line circuit (SLC) supports multiple device types of SK protocol, while the 5815XL signal line circuit (SLC) supports multiple device types of SD protocol. You cannot mix SD and SK SLC devices on a FACP. system silenced and system power System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1,000 events for viewing from the built - The 6820 has one built-in signaling in or remote annunciator. System line circuit (SLC) which supports multiple operations can be initiated with a devices. Additional points can be added using the 6815 SLC expanders to increase overall capacity to 1,110 maximum points (SK devices) or by adding up to four 5815XL SLC expanders to reach 635 maximum points (SD devices). The number of SLCs which can be used within one system is limited by point count. (See the Manual for additional information.) The 6820 SLC loops support multiple device types, maintenance alerts, and a built-in sensortestto complywith NFPA 72 calibration testing requirements. INDICATOR LIGHTS • General Alarm (Red): Flashes if in alarm; solid when alarm is silenced • Supervisory (Yellow): Flashes if a supervisory condition exists; solid when supervisory is silenced • System Troubles (Yellow): Flashes if a trouble condition exists; solid when trouble is silenced • System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared • System Power (Green): Flashes for AC failure; solid when power systems are normal USERINTERFACE The 6820 built-in 4 x 20 annunciator with 80 character LCD display and large easy -to -use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, mechanical firefighter's key or a valid 4- to 7-digit operator's code. PROGRAMMING The 6820 system offers several options to simplify and speed-up programming. JumpStart° AutoProgramming minimizes programming required to start a new system. The built-in keypad, or the 6860, 5860 or 6855 remote annunciators give you on -site access to current system programming. Programming can also be accomplished using the Windows° -based Honeywell Fire Software Suite (HFSS) program. SOFTWARE TOOLS SKST. Silent Knight Selection Tool provides the installer or design architect with a Windows° software system configuration tool to create a detailed Bill of Material (BOM) and battery calculations. HFSS: Honeywell Fire Software Suite provides communication and panel programming, detector status, event history and additional data. Requires a PC running Microsoft' Windows°. ADDITIONAL INFORMATION Twisted -unshielded pair wire is recommended. The 6820 also has 13 preset notification cadence patterns (including ANSI 3.41). AGENCY LISTINGS AND APPROVALS NFPA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72: Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non -coded) signaling services. • UL Listed: S2766 • CSFM:7165-0559:0500 • FDNY: COA# 6249 • FM approved ORDERING INFORMATION 6820: Addressable Fire Alarm Control Panel. (Red cabinet). COMPATIBLE ANNUNCIATORS 6860: 4x40 LCD remote fire annunciator (4 lines and up to 160 characters) per system; four programmable buttons 5860:4x20 LCD remote fire annunciator. 5860 is gray; 5860R is red 6855: 4x20 LCD remote fire annunciator 5865-3 or 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). The 5865-4 has key switches for silence and reset, and a system trouble LED. 5880: The 5880 LED / 10 module has 40 programmable LED outputs and eight supervised dry contact inputs which are useful for custom applications. You can use up to eight 5880 modules on one control panel for maximum flexibility. Its compact size allows mounting inside the annunciator, or in an accessory cabinet. 6820 COMPATIBLE DEVICES AND ACCESSORIES Seethe data sheets listed below for a complete listing of the SK, SD or SWIFT devices. 53623: SK Devices Data Sheet 53624: SD Devices Data Sheet 350614, 350616 & 350618: SWIFT wireless devices For a complete and current listing of compatible devices and accessories, visit www.siLentknight.com Important: You cannot mix SK and SD devices in the same fire alarm system. Page 2 of 4 — 351610:13 9/26/2018 SK COMPATIBLE ADDRESSABLE DEVICES SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperature SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T. Reflected beam smoke detector with test feature SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended airspeed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-W: Fixed thermal detector (135°F), white SK-HEAT-ROR: Fixed rate of rise detector (135°F) SK-HEAT-ROR-W: Fixed rate of rise detector (135°F), white SK-HEAT-HT: Fixed high temperature thermal detector (190°F) SK-HEAT-HT-W: Fixed high temperature thermal detector (190°F), white SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10 input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-W: Photoelectric smoke detector, white SK-PHOTO-T. Photoelectric smoke detector with thermal (135°F fixed temperature) SK-PHOTO-T-W: Photoelectric smoke detector with thermal (135°F fixed temperature), white SK-PHOTOR: Photoelectric detector with remote test capability SK-PHOTO-R-W: Photoelectric detector with remote test capability, white SK-PULL-SA: Add ressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2:Addressable Dual relay/ monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module 8300-6(-IV): 6" base for SK-W Series B21OLP: 6" mounting base B501(-WHITE, -IV, -130: 4" Flangeless base B501:4" Flangeless mounting base B200S(-IV, -WH): Intelligent sounder base B200S: Intelligent sounder base 13200S-LF(-IV, -WH): Low -frequency intelligent sounder base. B200S-LF: Low -frequency intelligent sounderbase B224RB(-IV, -WH): Relay base B224RB: Relay base B224B1(-IV, -WH): Isolator base B224B1: Isolator base SO COMPATIBLE ADDRESSABLE DEVICES SD505-6AB: Addressable 6" base SD505-61B: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6" relay base SD505-6SB: Addressable 6" sounder base SD500-AIM: Addressable input module (switch input) SD500-ANM: Addressable notification module SD500-ARM: Addressable relay module SD505-DTS-K: Remote test switch and LED indicator for theSD505-DUCTR SD505-DUCT:Addressable Duct Smoke Detector. SD505-DUCTR:Addressable Duct Detector housing with relay base. SD505-HEAT: Absolute temperature heat detector. Trip point range from 1350E-150OF(OOC-370C). SD500-LIM: Addressable Line isolator module SD500-MIM:Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA:Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module AUDIBLE/VISIBLE DEVICES These AV devices are all 2-wire. Color: "R" indicates red; `W" denotes white. For a complete listing of Silent Knight AV devices go to www.sitentknight.com. CHSRL/CHSWL: Wall chime/strobe CHSCRL/CHSCWL: Ceiling chime/strobe CHRL/CHWL: Wall chime HRL/HWL: Wall horn P2RL/P2WL: Wall horn/strobe PC2RL/PC2WL: Ceiling horn/strobe SRL/SWL: Wall strobe SCRL/SCWL: Ceiling strobe SPSCRL/SPSCWL: Ceiling speaker/strobe SPSRL/SPSWL: Wall speaker/strobe SPRL/SPWL: Wall speaker SPCRL/SPCWL: Ceiling speaker SWIFT WIRELESS DEVICES SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices WSK-WGI: Wireless Gateway WSK-PHOTO: Wireless Photoelectric smoke detector WSK-PHOTO-T: Wireless Multi -criteria photoelectric smoke detector with thermal detection (135°F fixed temperature) and B51OW 4" base WSK-HEAT: Wireless Heat, (135°F fixed temperature) and B510W 4" base WS K- H EAT-RO R: Wireless heat, ROR (135°F fixed temperature) and B510W 4" base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module W-USB: SWIFTTools USB transceiver used for communication with SWIFT devices SBUS ACCESSORIES 6815: Each Single Line Circuit allows for an additional 159 SK modules and 159 SK sensors to be added to the system -up to 1,110 total points. Supports System Sensor SK devices only. 5815XL: Each Single Line Circuit provides an additional 127 SD devices to be added to the system -for a maximum of 635 points. Supports SD devices only. 5496: A 6 amp notification power expander with four power -limited notification appliance circuit outputs. 5883: Relay Interface. Provides 10 Form C relays. 5824: Serial/Parallel Printer Interface Module for printer connection. 5895XL: Power Supply with six FlexputTM circuits, and two Form C relays. Max. 16 per system. 5815RMK: Remote mounting kit. Dimensions 10 3/8"W x 10-3/16"H x 3"D COMMUNICATION OPTIONS CELL-CAB-SK: Cellular communicator, metal enclosure with lock/key* CELL -MOD: Cellular communicator, plastic enclosure* *Sole path, powered by panel. IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-IP-2: Remote reporting via the Internet. Requires a VisorAlarm° receiver at the central station MISC. ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link for the 6820. SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber -Optic Multi Mode, transmitter and receiver SK-FSL: Fiber -Optic Single Mode RBB: Remote battery box accessory cabinet for batteries that are too large to fit in the FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406mm W x 254mm H x 152mm D). SK-SCK: Seismic Compliance Kit used to securely fasten batteries to the fire panel. Page 3 of 4 — 351610:13 9/26/2018 6820 Technical Specifications PHYSICAL FLEXPUT CIRCUITS Flexput°, Honeywell', Overall Dimensions: 16.36" W x 26.37" H x 3.91" D Six programmable circuits which can be JumpStart°, Silent Knight®, Shipping Weight: 32 lbs programmed individually as: SWIFT®, and System Sensor° are registered Color: Red Notification Appliance Circuits: 3A C 27.4VDC trademarks of Honeywell per circuit, power -limited (with a panel maximum International Inc. ENVIRONMENTAL current of 6A) Operating Temperature: 321Fto 120°F (0°C to Auxiliary power circuits: 3A C 27.4VDC per circuit, Hochiki° is a registered 49°C) power -limited trademark of Hochiki Corporation. MicrosoftQ Humidity: 0 to 93% relative humidity (non- Initiating Circuits (Circuits 5 and 6 Only): 100mA and Windows' are condensing) C 27.4VDC per circuit, power limited registered trademarks of Microsoft Corporation. ELECTRICAL Supports Class B (Style 4) and Class A (Style 6) This document is not 6820 Primary AC:120AC C 60Hz, 3.3ATotal configuration for SLC, SBUS, and Flexput circuits intended to be used for Accessory Load: 6A @ 27.4VDC power -limited installation purposes. We StandbyCurrent: 190mA WIRING: See the product manual for wiring details try to keep our product information up -to Alarm Current: 250mA date and accurate. We Batter Charging Capacity: 7 to 35AH Y 9� 9 p Y� cannot cover all specific ci Battery Size: 18AH max. allowed in control panel applications or anticipate cabinet. Larger capacity batteries can be housed in all requirements. All RBB accessory cabinet. specifications are subject to change without notice. For Technical Support, call 800-446-6444. Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 Honeywell 800-328-0103 351610 1 B 1 09/18 SILENT www.sitentknight.com © 2018 Honeywell International Inc. KRTIGNF Honeywell ®SILENT' NIGHT Remote Annunciator The 5860 remote annunciator, can be used to operate and program Honeywell Silent Knight fire alarm control panels (FACPs) from anywhere within the system. The 5860 features include an 80-character backlit LCD providing easy -to understand system messages. The annunciator is ergonomically designed with over -sized buttons for the most frequently used features, like Reset and Silence. _ In addition to status messages displayed o�e LCD, there are five LEDs lence for alarm, supervisory, trouble, si, and power status. The 5860 annunciator is available in gray t atch virtually any decor and red for applications where the annunciator st stand out. The annunciator enclosure can be surface orfl mounted. Atrim ring kit' available for surface mounting. COMPATIBILITY The 5860 is compatible with the following Honeywell Silent Knight FACPs: 6820: Addressable fire alarm control panel with up to 1,110 addressable points 6820EVS: Addressable fire alarm control panel with an emergency communication systems and up to 1,110 addressable points 6808: Addressable fire alarm control panel with up to 198 addressable points 6700: Addressable fire alarm control panel with up to 100 addressable points 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency communication systems 5808: Addressable fire alarm control panel 5700: Addressable fire alarm control panel FEATURES & BENEFITS • 80-character backlit LCD display (4 Lines with 20 characters per line) • Tactile / audible feedback when a key is pressed on the annunciator • Uses the RS-485 SBUS to interface with the panel • Supportfor simultaneous use of multiple 5860s • Easily view current status by alarms, supervisories, or troubles • Five Status LEDs • Available in red or light gray color • Accommodates wiring lengths up to 6000 ft. from the control panel for added design and install flexibility • Accepts user codes or fire fighter's key • Larger keypad buttons makes it easier to maneuver for system reset and silencing 5860 Technical Specifications Compatible Silent Knight FACP Wire Runs Up to 6000 Feet From FACP oa mu oa�e my �d�o mn ��m� 5860 5880 5860 to Eight 5860s Per 5700 or 6700 System to 12 5860s Per 5808, 6808, 5820XL, or 5820XL-EVS System • Up to 16 5860s per 6820 or 6820EVS System 5860 Features PHYSICAL Dimensions: 9.1"W x 7.4"H x 1.5"D (23.1W x 18.8H x 3.8D cm) Shipping Weight: 2.8 lbs (1.3 kg) Color: 5860R: Red; 5860: Gray ENVIRONMENTAL Operating Temperature:32°Fto 1201F(0°Cto 49°C) Humidity: 10%- 93% non -condensing) ELECTRICAL Operating Voltage: 24VDC Standby Current: 20mA Alarm Current: 25mA For more information Learn more about Honeywell Silent Knight and other products byvisiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 ORDERING INFORMATION 5860: Remote Annunciator, four line (4x20) LCD annunciator with 20 characters per line. Gray 586OR: Remote Annunciator, four line (4x20) LCD annunciator with 20 characters per line. Red ACCESSORIES 5860TR: Red Trim Ring for surface mounting 5860TG: Gray Trim Ring for surface mounting AGENCY LISTINGS AND APPROVALS UL listed CSFM approved Meets NFPA 72 requirements FM approved MEA approved Doc 350224 1 Rev J 112/17 © 2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit www.sitentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight° and Honeywell' are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We tryto keep our product information up -to date and accurate. We cannot coverall specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call800-446-6444. Honeywell SILENT' KNIGHT ft 'A0--W -f� ES,�� of SECURITY CORPORATION INNOVATION 7707 Fire Subscribers IntelliNet Introducing a Newer, Smarter Alarm Communications Platform New Feature Highlights aes-corp.com • Leverages state of the art technology • Applies advanced security protection no • Offers flexible power and configuration options NFPA • Engineered for backward compatibility with legacy systems • Enables future ready capabilities • Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button • Improves functionality with an adaptive Graphic User Interface (GUI) for programming via smartphones, tablet and PCs • Plus many more... U� LISTED Key Benefits that Make 2.0 the Best Alarm Monitoring Solution Ever • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks • Protects subscriber units against unauthorized access and rogue activity with a password protected Dealer Code • Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-IntelliPro full data module • Provides versatile power options: (1) Direct from the Fire Alarm Control Panel (FACP) without requiring an electrician onsite and without Subscriber backup battery (2) Directly from the FACP with Subscriber backup battery; or (3) Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network. The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data module option, they are the ideal drop -in replacement for Plain Old Telephone Service (POTS) lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status. The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop, tablet, or integrated Universal Serial Bus (USB)—without the need for special cables or having to use a handheld programmer. Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network D} Burglary Subscriber-—-—---—-—-—-—- wi B r I N i ► I rr 1 BJFire r r Subscriber I I I I Mi,Nen.erk RioneBeM.n! SrsMm B- -- - Ay Alarm — Primary AES-MuVrlNer Re(river I I I I I Panel I I Selo ndary AE S•MuIflNef He[eluer r' I I r B I B •C Alarm Automation A _ _ _ _ _ _ _ Q IIP Links Customer Location Mesh Radio Technology Central MonIto ring Staticn Alarm Panel & AES Su bs(ri per Multi-patlr AE S-krtel iNeM Network Primary& Secon da ry AES-h1ujdNet Syslern sends critical ever r[signal delivers alarm sign als via smart routing, receives transmi ssia n in 1-3 seconds The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add -on accessory board. AES subscribers' intelligent software automatically detects new hardware and devices to reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming. A laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units. A FACP Power Supply Adapter is required for certain configurations when using flexible power options. The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians to get in, out, and on to the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: http://aes-corp.com/products/fire/fire-marshal-resources/ How to Order 7707 Fire IntelliNet 2.0 Fire Subscribers PREMIUM (UL & ULC Listed, Available Now!) IntelliNet 2.0 Fire Subscriber, 8 Zone, 8 Supervised Zones, with integrated onboard 7707P-88 Local Annunciator, Red Enclosure IntelliNet 2.0 Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794A AES-IntelliPro 7707P-88-ULP and integrated onboard Local Annunciator, Red Enclosure IntelliNet 2.0 Fire Subscriber, 4 Zone, 4 Supervised Zones, with integrated onboard 7707P-44 Local Annunciator, Red Enclosure IntelliNet 2.0 Fire Subscriber, 4 Zone, 4 Supervised Zones with 7794A AES-IntelliPro 7707P-44-ULP and integrated onboard Local Annunciator, Red Enclosure 2.0 FEATURE ADD (Pending UL Review) IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies 7707P-88-M (MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated 7707P-88-ULP-M onboard Local Annunciator plus MCT, Red Enclosure IntelliNet 2.0 Fire Subscriber, 4 Zone with Multiple Communication Technologies 7707 P-44-M (MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber, 4 Zone with 7794A AES-IntelliPro, and integrated 7707P-44-ULP-M onboard Local Annunciator plus MCT, Red Enclosure 7707M-UPG IntelliNet 2.0 Fire MCT Software Upgrade 2.0 ACCESSORIES Standalone AES-IntelliPro Fire full data module add -on accessory board with 7794A firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-way Junction Box Legacy• •- 7706-ULF Integrated Fire Monitoring System, Red Enclosure Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro (7794 full data module, 7788F-ULP-P 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro, 7788F-ULP Red Enclosure 7788F Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure Legacy Fire Subscriber, 4 Zone with 7795 AES-IntelliPro (7794 full data module, 7744F-ULP-P 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure Legacy Fire Subscriber, 4x4 Zone, 4 Supervised Zones with 7794 AES-IntelliPro, 7744F-ULP Red Enclosure Legacy Fire Subscriber, 4x4 Zone, 4 Reversing Polarity, 4 Supervised Zones, 7744F Red Enclosure LEGACY ACCESSORIES Standalone AES-IntelliPro Fire full data module add -on accessory board for legacy 7794 units only, please see 7794A above for IntelliNet 2.0 version Technical Specifications 7707 Fire DIMENSIONS 13"H x 8.5"W x 4.5"D (33cmH x 21.5cmW x 11.4cmD) WEIGHT 5.8 Ibs (2.6 kilograms) excluding battery 13 Ibs (5.9 kilograms) with 10 Ah battery RADIO FREQUENCY Standard Frequency Range: 450-470 MHz Contact AES for other UHF and VHF frequencies ANTENNA 2.5 dB tamper resistant antenna included, mounts on enclosure Optional remote mounting antenna available POWER INPUT AC SOURCES Transformer: Class 2 16.5V AC nominal output 1.9 A max current (40 VA MIN) ELK ELK-TRG1640, MG ELECTRONIC SALES MGT1640, or AES 1640 (not included) DC SOURCES (includes FACP) 24V DC Regulated Power Supply with Subscriber Rechargeable Battery 1.9 A max current BACKUP BATTERY 10-12 Ah, UL recognized lead acid gel cell, size based on subscriber configuration Contact Us ALARM SIGNAL INPUTS/ZONES 8 individually programmable E.O.L. type zone inputs 4+4: 4 reverse polarity input and 4 individually programmable E.O.L. type zone inputs Optional 7794A AES-IntelliPro for full data via Contact ID, Pulse, Modem Ile and Modem IIIa2 UL LISTINGS UL 864 loth Edition Standard for Control Units and Accessories for Fire Alarm Systems ULC S559-04 1st Edition Equipment for Fire Signal Receiving Centres and Systems TROUBLE OUTPUT—ACK DELAY/ANTENNA CUT Form C relay, fail secure, rated 24V DC 1A resistive, unsupervised RESET BUTTON Located on main circuit board OPERATING TEMPERATURE 32 to 120°F (0 to 49°C) STORAGE TEMPERATURE 14 to 140°F (-10 to 60oC) RELATIVE HUMIDITY 0 to 93%, non -condensing RECHARGE CAPABILITY Will charge 12V battery size from 10-12 Ah PORTS Ethernet for configuration and message communication USB access for software upgrade REMOTE ANNUNCIATOR AES Model 7740 Remote Annunciator, supervised COMPATIBLE RECEIVERS 7705i AES-MultiNet Receiver CONFIGURATION INTERFACE Web browser capable device accessible via smartphone, tablet, laptop, or PC CURRENT CONSUMPTION Standby w/ charged backup battery: 200 mA (1.2 A Transmitting) Standby + charging backup battery: 900 mA (1.9 A Transmitting - MAX) POWER OUTPUT 2 or 5 Watts Factory set ENCLOSURE MATERIAL Steel with paint finish FINISH COLOR Red VISUAL INDICATORS Front panel LCD (2 x 20 alphanumeric character backlit display) Power and Trouble LEDs (ALM, Trouble, Tx, Rx, WA) For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com. Honeywell ® SILENT'xl CHT WSK-WGI Intelligent Wireless Devices SWIFT° Wireless Gateway The SWIFT (Smart Wireless Integrated Fire Technology) Wireless System can be applied in many situations that are problematic for traditional wired devices. In cases where areas of a building are difficult or impossible to wire, visually sensitive, or have restricted access, SWIFT wireless sensors provide an efficient, reliable solution. SWIFT wireless devices communicate via a pro prietarywireless mesh protocol to communicate with a Silent Knight° fire alarm system by means of a SWIFT wireless gateway. The SWIFT gateway connects to the SLC loop of a 6700, 6808, 6820/EVS panel using SK protocol. New type IDs for wireless devices are supported that allow the FACP to display all events such as alarms and trouble indications, as well as unique trouble conditions required for wireless devices. This capability eliminates the need for a supplementary annunciator for wireless event messages. Wireless devices in a SWIFT network develop "parent -child" communication links with other devices in the mesh, so that a message originating from a remote device "hops" to the closest parent device, and then to successive parent devices until the message reaches gateway. Alternate paths are also identified and supervised by the SWIFT protocol providing approved Class A wireless communication. If a device does not have an established communication path with adequate signal strength, an additional device such as a wireless module may be installed in between so that it will act as a repeater. A SWIFT gateway system supports up to 50 devices:1 SWIFT gateway and up to 49 wireless detectors, modules, pullstations, and A/V bases. The maximum number of gateways on a system is limited by the number of available SLC addresses on the FACP, or a maximum of 4 gateways within common wireless range. FEATURES & BENEFITS • Wireless mesh technology (902-928 MHz frequency) • Any wireless device can be added to act as a repeater • Cascading -wave mesh operation provides a verification of redundant communication paths • Each SWIFT gateway system supports up to 50 devices: 1 wireless gateway and up to 49 devices • Standard "code wheel" for setting the SLC address • Up to 4 wireless networks can be installed with overlapping radio network coverage • Site Survey feature allows for an evaluation of a site before the installation • Wireless devices use (4) CR-123A lithium batteries • Battery Life — UL listed for 2 years The SWIFT system has been designed so that it can be installed using only typical hand tools and magnets. However, the SWIFT Tools PC utility provides many benefits that can enhance the process of performing a site evaluation (Site Survey), installing a system (Mesh Configuration), or extracting detailed information from the system (Diagnostics). The utility runs on a Windows° laptop, and uses a USB radio antenna (W-USB) inserted into a USB slot to communicate with wireless devices within range of the PC. Once devices have formed a mesh, SWIFT Tools can provide current information on all devices in the mesh as long as the PC is within range of the SWIFT Gateway. The result is a fire system that combines both wired and wireless detection and presents all event information at the panel and/or network displays, when used. Compatible Control Panels • 6700 • 6808 • 6820 • 6820EVS SWI FT Tools SWIFT Tools is a Windows PC -based utility that is used for site evaluation, system configuration, and diagnostics. The SWIFT Tools program is used with the W-USB adapter to communicate with wireless devices that are notjoined in a network, or with one or more wireless gateways and all devices that have formed a network with each gateway. A graphic representation of the wireless network provides important system data in an effective format, including communication links, signal strength, battery voltage, and more. Tool -less operation is supported, allowing you to perform site evaluation and system configuration and installation can be accomplished without using SWIFT Tools when necessary. Multi- colored LEDs on SWIFT devices provide feedback for interactions. At any point, only one instance of SWI FT Tools can run on a laptop or PC. SWIFT Tools has the following utilities: • Site Survey • Create Mesh Network • Diagnostics SWIFT Tools works in a wireless environment with the WSK-WGI and devices within a range of approximately 20 feet. SWIFT Tools is designed for systems running Microsoft' Windows°. Minimum System Requirements Operating System: Windows 7 and Windows 8 (32 bit and 64 bit). Hard Drive: 20 GB hard drive space with minimum 1GB free space on hard disk. MAKIIII-11TT MA Processor speed:1GHz minimum (2.4 GHz recommended) Processor. 512K Cache. SWIFT Components and Ordering Information • WSK-WGI: Wireless SWIFT Gateway- 1 SWIFT Gateway is required for each wireless mesh, and supports up to 49 SWIFT detectors or modules. Connects to the SLC loop of a compatible panel using SK protocol. Power may be supplied by the SLC circuit or via an optional24VDC input. Note: Use of the 24VDC input maybe more convenient for service as it allows for powering down a gateway without shutting down an SLC loop. • WSK-PHOTO: Intelligent, wireless photo detector. Ships with B501W base included. Requires (4) CR-123A batteries (included). • WSK-HEAT-ROR: Intelligent wireless rate of rise (1359 heat detector. Ships with B501W base included. Requires (4) CR-123A batteries (included). • WSK-PHOTO-T: Intelligent wireless photo/heat detector. Ships with B501W base included. Requires (4) CR-123A batteries (included). • WSK-HEAT: Intelligent wireless fixed -temperature (1351) heat detector. Ships with B501W base included. Requires (4) CR-123A batteries (included). • WSK-MONITOR: Wireless monitor module. Used to monitor devices with mechanical contact actuation. Includes a special cover with a built- in tamper magnet. Recommended for installation in a SMB500-WH box (ordered separately) rather than a metal backbox for best performance. Requires (4) CR-123A batteries (included). • WSK-RELAY: Wireless relay module for use with the WSK-WGI wireless gateway. Includes a special cover with a built-in tamper magnet. Recommended for installation in an SMB500-WH box (ordered separately) rather than a metal backbox for best performance. Requires (4) CR-123A batteries (included). • WSK-PULL-DA: Wireless addressable pullstation. Requires (4) CR-123A batteries (included). • WAV-CRL, WAV-CWL: SWIFT Wireless Addressable A/V bases. Requires (8) CR-123A batteries (included). Requires a non - compact ceiling System Sensor' L-series notification device (ordered separately). • W-SYNC: Wireless sync module. Requires (4) CR-123A batteries (included). • SMB500-WH: Optional surface -mount backbox. • SWIFT Tools: Programming and diagnostic utility. Free download from www.sitentknight.com. For installation on a (typically laptop) PC running an approved version of Windows (See Minimum Page 2 of 4 — 351618:B • 10/3/2018 System Requirements for SWI FT Tools). Requires the W-USB radio/ antenna don gle for communication with SWIFT Wireless devices. • W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. The W-USB provides a communication link with SWIFT Wireless devices that are within approximately 20 feet and have not formed a mesh. Alternately, when the devices have formed a mesh, bringing the PC/W-USB within range (20 ft.) of the gateway for that mesh will allow SWIFT Tools to acquire information on all devices in that mesh, including point-to-point signal strength for all links. • W-BATCART: Wireless battery cartridge,10-pack. For use with the wireless pullstations and AN bases. Page 3 of 4 — 351618:B • 10/3/2018 W$K-WGI Technical Specifications PHYSICAL AGENCY LISTINGS AND APPROVALS Silent Knight°, System Sensor®, and SWIFT° are Height: 1 7/8" (4.5 cm) The listings and approvals belowapplyto the WSK-WGI. In registered trademarks of Diameter: 7 7/8" (20 cm) some cases, certain modules may not be listed by certain Honeywell International Inc. OPERATING approval agencies or listing may be in process. Consult Microsoft® and Windows® are factory for latest listing status. registered trademarks of 0 0 o Operating Temperature Range: 32 Fto 120 F (0 C to UL Listed: S3511 Microsoft Corporation. Duracell' is a registered 490C) CSFM: 7300-0559:0510 trademark of Duracell U.S. Operating Humidity Range: 10%to 93% non- FM Approved Operations Inc. Panasonic° is condensing FCC ID: PV3WFSGW a registered trademark of ELECTRICAL Panasonic Corporation. STANDARDS AND CODES ©2018 by Honeywell External Supply Electrical Ratings: 18V- 30VDC The SWIFT Wireless System complies with the following International Inc. All rights reserved. Unauthorized use of SLC Electrical Ratings: 15V - 30VDC UL Standards and with NFPA 72 Fire Alarm system this document is strictly Maximum ambient noise level: -85 dBM requirements. prohibited. Minimum signal strength level for trouble report: -55 UL 864 This document is not intended dBM UL 268 to be used for installation Maximum RF power output: +17 dbM purposes. We try to keep our Radio Frequency: 902-928 Hhz (lower ISM band) product information up-to- date and accurate. We cannot VW -GATE: cover all specific applications Maximum current (when powered by 24VDC): 40 mA or anticipate all requirements. All specifications are subjectto Maximum current (when powered by SLC): 24 mA change without notice. VW-DIS-D: Country of origin: Mexico Maximum current: 30 mA Maximum SLC resistance: 50 ohms Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 Honeywell 203.484.7161 3516181 e 1 10/18 13 SILENT' www.sitentknight.com ©2018 Honeywell International Inc. KNIGHT mW SERIES Addressable Photoelectric Smoke Detectors The Silent Knight"' SK-PHOTO-W Series feature a modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The SK-PHOTO-W Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the SK-PHOTO Series detectors. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (5710 fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detector for use with DN R Series duct detector housings. FEATURES AND BENEFITS • Designed to meet UL 1268 7th Edition • Sleek and stylish contemporary design • Stable communication technique with noise immunity • Addressable by device • Rotary, decimal addressing (Refer to the Silent Knight panel manuals for device capacity) • Two -wire SLC connection • LEDs blink everytime the unit is polled • 3601-field viewing angle of the visual alarm indicators (two bi-color LEDs); LEDs blink green in Normal condition and turn on steady red in Alarm • Integral communications and built-in device -type identification • Remote test feature from the panel • Built-in functional test switch activated by external magnet • Walk testwith address display (an address of 121 will blink the detector LED 12- (pause)-1) • Low standby current • Built-in tamper -resistant feature • Designed for direct -surface or electrical - box mounting • Sealed against back pressure • Plugs into separate base for ease of installation and maintenance • Expanded color options • SEMS screws forwiring of the separate base • Optional remote, single -gang LED accessory • Optional sounder, relay, and isolator bases Honeywell SILENT' KNIGHT INSTALLATION The SK-PHOTO-W Series plug-in intelligent thermal detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see SK-61045. Note: Because of the inherent supervision provided bytheSLC loop, end -of -line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class "B") wiring. Note: When using relay or sounder bases, consult the SK-ISO installation sheet 156-3627 for device limitations between isolator modules and isolator bases. OPERATION Each SK-PHOTO-W Series detector uses one of the panel's addresses (total limit is panel dependent) on the Signaling Line Circuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The SK-PHOTO-W Series offers features and performance that represent the latest in smoke detector technology. PRODUCT LINE INFORMATION Note: "-IV" suffix indicates ivory color. SK-PHOTO-W: White, low -profile photoelectric sensor SK-PHOTO-T-W: White, same as SK-PHOTO-W but includes a built-in 1350F (57°C) fixed -temperature thermal device SK-PHOTO-R-W: White, low -profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW B300-6: White, standard flanged low -profile mounting base B300-6-BP: Bulk pack of B300-6, package contains 10 B300-6-IV: Ivory, standard flanged low -profile mounting base B501-WHITE: White, standard European flangeless mounting base B501-BL: Black, standard European flangeless mounting base B501-IV: Ivory, standard European flangeless mounting base B501-WHITE-BP: Bulk pack of 3501-WHITE, contains 10 B20OS-WH: White, Intelligent, programmable sounder base B20OS-IV: Ivory, Intelligent, programmable sounder base B200SR-WH: White, Intelligent sounder base for retrofit applications B200SR-IV: Ivory, Intelligent sounder base for retrofit applications B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounderbase B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounderbase B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications B224RB-WH: White, plug-in System Sensor' relay base B224RB-IV: Ivory, plug-in System Sensor relay base B224BI-WH: White, plug-in System Sensor isolator detector base B224BI-IV: Ivory, plug-in System Sensor isolator detector base ACCESSORIES TR300: White, replacement flange for B21OLP or B300-6 bases TR300-IV: Ivory, replacement flange for B21OLP or B300-6 bases RA100Z(A): Remote 3 - 32 VDC LED annunciator, mounts to a U.S. single -gang electrical box, for use with B501 and B300-6 bases only M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: White, detector color kit, pack of 10 CK300-IV: Ivory, detector color kit, pack of 10 CK300-BL: Black, detector color kit, pack of 10 Page 2 of 3 — 351634:13 • 7/1/2019 SK-PHOTO-W SERIES TECHNICAL SPECIFICATIONS PHYSICAL/ENVIRONMENTAL Sensitivity: - UL Applications: 0.5% to 4.0% per foot obscuration. - ULC Applications: 0.5%to 3.5% per foot obscuration Size: 2.0" (5.3 cm) high; base determines diameter - B300-6: 6.1" (15.6 cm) diameter - B501: 4" (10.2 cm) diameter For a complete list of detector bases, see SK-61045. Shipping weight: 3.4 oz. (95 g) Operating temperature range: • SK-PHOTO-W:32°Ftol22°F(0°Cto50°C) • SK-PHOTO-T-W: 32°F to 100°F(0°C to 38°C) • SK-PHOTO-R-W installed in a DNR/DNRW: -4°F to 158°F (-20°C to 70°C) UL/ULC Listed Velocity Range: 0-4000 ft/ min. (1219.2 m/min.), suitable for installation in ducts Relative humidity: 10%— 93% non - condensing Thermal ratings: fixed -temperature set point 1350F (57C), rate -of -rise detection 15°F (8.3°C) per minute, high temperature heat 190OF(88°C) ELECTRICAL SPECIFICATIONS Voltage range:15 - 32 volts DC peak Standby current (max. avg.): 200pA @ 24 VDC (one communication every 5 seconds with LED enabled) Max current: 4.5 mA @ 24 VDC ("ON") Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.sitentknight.com DETECTOR SPACING AND APPLICATIONS Silent Knight recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1m). For specific information regarding detector spacing, placement, and special applications referto N FPA 72. A System Smoke Detector Application Guide, documentA05-1003, is available at www.systemsensor.com. AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document.ln some cases, certain modules or applications may not be listed bycertain approval agencies, or listing may be in process. Consult factory for latest listing status. • ULListed:S6173 • FM Approved • CSFM:7272-0559:0512 351634 1 B 1 07/19 ©2019 Honeywell International Inc. Honeywell SILENT' KNIGHT VnATmW SERIES Addressable Heat Detectors The Silent Knight"' SK-HEAT-W Series heat detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and advanced thermal technologies make the SK-HEAT-W Series ideal for both system operation and building design. The series includes a 1351F/571C fixed -temperature, rate -of -rise, and a 1801F/881C fixed high -temperature detectors and are direct replacements for the SK-HEAT Series heat detectors. The point ID address, set using rotary decimal switches, provide specific detector locations. These thermal detectors provide effective, intelligent property protection in a variety of applications. • SK-HEAT-W offers 135OF fixed thermal detection. • SK-HEAT-ROR-W offers 1350F fixed and rate -of -rise thermal detection. • SK-HEAT-HT-W provides fixed high -temperature detection at 190°F. FEATURES AND BENEFITS • Designed to meet UL 268 7th Edition • Sleek and stylish contemporary design • Advanced thermal technology for fast response • Fixed temperature model(SK-HEAT-W) factory preset to 135°F (57°C) • Rate -of -rise model (SK-H EAT-ROR-W), 15°F (8.3°C) per minute • High temperature model (SK-HEAT-HT-W) factory preset to 190OF (88°C) • Addressable by device • Rotary, decimal addressing (Refer to the Silent Knight panel manuals for device capacity) • Two -wire SLC connection • LEDs blink everytime the unit is polled • 3600-field viewing angle of the visual alarm indicators (two bi-color LEDs); LEDs blink green in Normal condition and turn on steady red in Alarm • Integral communications and built-in device -type identification • Remote test feature from the panel • Built-in functional test switch activated by external magnet • Walk testwith address display (an address of 121 will blink the detector LED 12- (pause)-1) • Low standby current • Built-in tamper -resistant feature • Designed for direct -surface or electrical - box mounting • Sealed against back pressure • Plugs into separate base for ease of installation and maintenance • SEMS screws forwiring of the separate base • Optional remote, single -gang LED accessory • Optional sounder, relay, and isolator bases • Optional flanged surface mounting kit Honeywell SILENT' KNIGHT APPLICATIONS Use thermal detectors for protection of property. For further information, refer to manual 156-6529, Applications Manual for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications. INSTALLATION The SK-HEAT-W Series plug-in intelligent thermal detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see SK-61045. Note: Because of the inherent supervision provided bytheSLC loop, end -of -line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class "B") wiring. Note: When using relay or sounder bases, consult the SK-ISO installation sheet 156-3627 for device limitations between isolator modules and isolator bases. PRODUCT LINE INFORMATION SK-HEAT-W: White, low -profile intelligent 1351Ffixed thermal sensor SK-HEAT-ROR-W: White, low -profile intelligent rate -of -rise thermal sensor SK-HEAT-HT-W: White, low -profile intelligent 190°F fixed thermal sensor B300-6: White, standard flanged low -profile mounting base B300-6-BP: Bulk pack of B300-6, package contains 10 B300-6-IV: Ivory, standard flanged low -profile mounting base B501-WHITE: White, standard European flangeless mounting base B501-BL: Black, standard European flangeless mounting base B501-IV: Ivory, standard European flangeless mounting base B501-WHITE-BP: Bulk pack of 3501-WHITE, contains 10 B200S-WH: White, Intelligent, programmable sounder base B200S-IV: Ivory, Intelligent, programmable sounder base B200SR-WH: White, Intelligent sounder base for retrofit applications B200SR-IV: Ivory, Intelligent sounder base for retrofit applications B200S-LF-WH: White, Low Frequency Intelligent, programmable sounderbase B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounderbase B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications B224RB-WH: White, plug-in System Sensor' relay base B224RB-IV: Ivory, plug-in System Sensor relay base B224BI-WH: White, plug-in System Sensor isolator detector base B224BI-IV: Ivory, plug-in System Sensor isolator detector base ACCESSORIES TR300: White, replacement flange for B210LP or B300-6 bases TR300-IV: Ivory, replacement flange for B21OLP or B300-6 bases RA100Z(A): Remote 3 - 32 VDC LED annunciator, mounts to a U.S. single -gang electrical box, for use with B501 and B300-6 bases only M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: White, detector color kit, pack of 10 CK300-IV: Ivory, detector color kit, pack of 10 CK300-BL: Black, detector color kit, pack of 10 Page 2 of 3 — 351637:13 • 7/1/2019 SK-HEAT-W SERIES TECHNICAL SPECIFICATIONS PHYSICAL/ENVIRONMENTAL Size: 2.0" (5.3 cm) high; base determines diameter -B300-6: 6.1" (15.6 cm) diameter -B501: 4" (10.2 cm) diameter For a complete list of detector bases, see S K-61045. AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document.In some cases, certain modules or applications may not be listed bycertain approval agencies, or listing may be in process. Consult factory for latest fisting status. Operating temperature range: SK-HEAT-W, . UL Listed: S6228 SK-HEAT-ROR-W:-4°Fto 100OF • FM Approved (-20°C to 38°C) • CSFM: 7270-0559:0511 S K-H EAT-HT-W: -4° F to 150O F (-20°C to 66°C) Detector spacing: UL approved for 50 ft. (15.24 m) centerto center; FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing Relative humidity: 10% — 93% non - condensing Thermal ratings: Fixed -temperature set point 135°F (5710, rate -of -rise detection 15°F (8.3°C) per minute, high temperature heat 190°F(88°C) ELECTRICAL SPECIFICATIONS Voltage range:15 - 32 volts DC peak Standby current (max. avg.): 200uA @ 24 VDC (one communication every 5 seconds with LED enabled) LED current (max.): 4.5mA @ 24 VDC ("ON") Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.sitentknight.com 351637 1 B 1 07/19 ©2019 Honeywell International Inc. Honeywell SILENT' KNIGHT 'NTE Standard, Relay, Isolator, Sounder, and Low Frequency Sounder Bases To meet local code and application requirements, Silent Knight° offers standard 4" and 6" bases, as well ass peciatty base designs including relay, isolator, sounder and low frequency sounder bases that are UL listed for low frequency operation and comply with NFPA 72 requirements for sleeping spaces for the new SK-W Series of addressable detectors as well as previous generations. The standard 4" and 6" bases offer a plug-in detector base intended for use in intelligent systems, with screw terminals provided for power (+ and —), and remote annunciator B300-6 Standard 6" connections. Communication takes place over the power (+ and —) lines. The 4" base offers a Base (White) compact design while the 6" base provides compatibility with a wider range of junction boxes. The specialty bases support application driven requirements. These bases employ a separate mounting plate that installs on variousjunction box sizes to eliminate unsightly surface -mount boxes. The mounting plate enables pre -wiring of all connections to speed and simplify installation. Relay bases (B224RB-WH/B224RB-IV) provide one form-C contact relayfor control of auxiliary functions, such as door closure and elevator recall. The relay can operate in two different modes (short and long delay). The activation time forthe short delay is 60-100 milliseconds, while the activation time for the long delay is 6-10 seconds. A shunt with pin headers, located on the base PC board, is used to set the delay timing. Isolator bases (B224B1-WH/B224B1-IV) allowthe Signaling Line Circuit (SLC) loop to operate under fault conditions created from a short circuit preventing an entire communication loop from being disabled. The base isolates the section of the loop containing the short circuit from the remainder of the circuit and automatically restores when the fault is corrected. Sounder and low frequency (-LF) sounder bases are designed for new and existing dwelling unit applications. They offer maximum flexibility in installation, configuration, and operation to meet or exceed UL268 and UL464 requirements. The low frequency sounder bases are designed to meet the NFPA 72 sleeping space requirementto produce a fundamental frequency of 520 Hz +/-10%with a square wave or its equivalent. Studies show that a lower frequency, centered around 520 Hz, is the most ideal to wake sleeping occupants, even those with mild to severe hearing loss. FEATURES AND BENEFITS • Bases enable quick and secure detector • Standard white color with ivory and black plug-in • SEMS Screws provide easy wiring connection • UL 268 compliant • Support for 12-24 AWG provides installation flexibility • Multiple base formats meet application requirements options • Mechanical locking feature restricts removal of attached sensor head • Specialty Base Features: • Pre -wired mounting plate simplifies installation • Application driven feature sets B20OS-WH Sounder Base (White) B300-6-IVStandard 6" Base (Ivory) B20OS-LF-WH Low Frequency Sounder Base (White) B501-WHITE Flangeless B501-BL Flangeless 4" Base (White) 4" Base (Black) • Sounder bases both UL268 and UL464 compliant Honeywell SILENT' EMGHT The B200S sounder and LF sounder bases (B200S-WH/B200S-IV/ B224BI-WH: White, isolator detector base B200S-LF-WH/B200S-LF-IV) adopt the same address as the detector, but use a unique device type on the loop. The Fire Alarm Control Panel (FACP) can use that address to command an individual sounder — or a group of sounders — to activate. The command set from the FACP can be tailored to multiple event - driven tone outputs allowing selection of volume (75 or 85 dBA), tone (ANSI Temporal 3, ANSI Temporal4, or March Time) and group. In addition, some FACPs will enable custom tone patterns. The B200S series sounder bases recognize the System Sensor synchronization protocol. This enables them to be used as a component of the general evacuation signal — along with other System Sensor AV appliances — when connected to a power supply or FACP output capable of generating the System Sensor synchronization pulses. The B200SR sounder and LF sounder bases (B200SR-WH/ B200SR-IV/B200SR-LF-WH/B200SR-LF-IV) are fully compatible with existing B501BH Series sounder base installations. The device enables users to select one of two B501-supported tones (ANSI Temporal 3 or Continuous) through a jumper. PRODUCT LINE INFORMATION INTELLIGENT BASES "-IV" suffix indicates Ivory color model. "-K' suffix indicates Black color model. "-WH" and "-WHITE" suffix indicates White color model. B300-6: White, 6" base, standard flanged low -profile mounting base; replacement base for the 3210LP. B300-6-BP: Bulk pack of B300-6, package contains 10; replacement for the B210LPBP. B224BI-IV: Ivory isolator detector base B20OS-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone; Uses SK protocol B20OS-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone; Uses SK protocol B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz +/- 10%with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz +/- 10%with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone; Intended for retrofit applications B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone; Intended for retrofit applications B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz+/-10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement; intended for retrofit applications B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz+/-10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applications. MOUNTING KITS AND ACCESSORIES B300-6-IV: Ivory,6" base, standard flanged low -profile mounting base. TR300: White, replacement flange for B300-6 base B501-WHITE: White, 4" standard European flangeless mounting TR300-IV: Ivory, replacement flange for B300-6-IV base base. UL/ULC listed RA10OZ: Remote LED annunciator, 3 - 32 VDC, mounts to a U.S. B501-WHITE-BP: Bulk pack of 3501-WHITE, contains 10 single -gang electrical box; For use with B501 and B300-6 B501-BL: Black, 4" standard European flangeless mounting base B501-IV: Ivory color, 4" standard European flangeless mounting base B224RB-WH: White, relay base B224RB-IV: Ivory, relay base JUNCTION BOX SELECTION GUIDE M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: White, detector color kit, pack of 10 CK300-IV: Ivory, detector color kit, pack of 10 CK300-BL: Black, detector color kit, pack of 10 Base Models Single Gang Double Gang 3.5" Oct. 4.0" Oct. 4.0" Square 4.0" Square with 3.0" mud ring 50 mm 60 mm 70 mm 75 mm B200S,B200SR Yes Yes Yes Yes Yes Yes No No No No B501 No No Yes No No Yes Yes Yes Yes No B300-6 Yes No Yes Yes Yes Yes No No No No B224BI, B224RB Yes Yes Yes Yes Yes Yes No No No No Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. Applies to all model variants "BL", "-LF", "-IV", "-WH", and "-WHITE". See Product Line Information for detailed model description. Page 2 of 3 — SK-61045:13 • 7/8/2019 INTELLIGENT BASES TECHNICAL SPECIFICATIONS ELECTRICAL For B300-6 Series bases: • Operating voltage: 15 to 32 VDC • Standby current:170 pA maximum For B501 Series bases: • Operating voltage: 15 to 32 VDC • Standby current:150 pA maximum For B200 Series bases: • External supply voltage:16 to 33 VDC (FWR) • Standby current: 500 pA maximum • Alarm current for B200S(-IV)(-WH): 35 mA maximum at high -volume setting 15 mA maximum at low -volume setting • Alarm currentfor B200S-LF(-IV)(-WH) High - volume setting: 70 mA maximum @ 33.0 VDC 90 mA maximum @ 24.0 VDC 140 mA maximum @16.0 VDC • Alarm current for B20OS-LF(-IV)(-WH) Low - volume setting: 15 mA maximum C 33.0 VDC 20 mA maximum C 24.0 VDC 25 mA maximum C 16.0 VDC • Alarm current for B200SR(-IV)(-WH): 35 mA maximum • Alarm current for B200SR-LF(-IV)(-WH): 65 mA maximum C 33.0 VDC 90 mA maximum C 24.0 VDC 125 mA maximum C16.0 VDC SLC operating voltage: 15 to 32 VDC SLC standby current: See applicable sensor specification Sound output: Greaterthan 85 dBA minimum; measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone) For 1322413I, B224RB (-IV) (-WH) bases: • Operating voltage: 15 to 32 VDC (powered by SLC) • Standby ratings: <450 pA maximum @ 24VDC • Set time: (B224RB(-IV)(-WH) only): short delay 60-100 msec; long delay 6-10 seconds • Reset time: (B224RB/-IV/-WH only): 20 milliseconds maximum • Relay characteristics: (13224RB/-IV/-WH only): two -coil latching relay; one Form-C contact; ratings (UL/CSA): 0.9 A C 125 VAC, 0.9AC110VDC, and 3.0AC30VDC PHYSICAL Note: Specifications applies to all model variants "-BL", "-LF", "-IV", -WH, -WHITE. See Product Line Information for detailed model description. Diameter: • B501-WHITE:4" (10.16 cm) • B300-6, : 6.1" (15.49 cm) • 1322413I, 8224RB: 6.2" (15.748 cm) • B200S, B200SR: 6.875" (17.46 cm) Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.sitentknight.com Wire gauge: • B224B1,B224RB:14to24AWG • B300-6, B501, B200S, B200SR12 to 24 AWG Temperature range: • B224BI, B224RB, B200S, B200SR: 32°Fto 120°F (0°C to 49°C) • B300-6, B501: -4°F to 150°F (-20°C to 66°C) Humidity range: 10%to 93% RH, non - condensing System temperature and humidity ranges: This system meets NFPA requirements for oper- ation at 0°C to 490C (32°F to 120°F); and at a relative humidity (non -condensing) of 85%at 30°C (86°F) per NFPA, and 93%± 211/6 at 32°C ± 2°C (89.6°F ± 1.1°F) per ULC. However, the use- ful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended thatthis system and all peripherals be installed in an environmentwith a nominal room temperature of 15°C to 27°C (60°F to 8019. AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S911 FM Approved CSFM: 7300-1653:0109, 7300-1653:0126, 7300-1653:0213, 7300-1653:0238 SK-61045 I B 1 07/19 ©2019 Honeywell International Inc. Honeywell ®SILENT' I acir SK-MINIMON Intelligent Mini Monitor Mom The SK-MINIMON is an addressable monitor modules for use with the Honeywell Silent Knight fire alarm control panels (FACPs). The SK- MINIMON acts as an interface to contact devices, such as waterflow switches and pullstations.The SK-MINIMON supports Class B supervised wiring to the load device. Conventional4-w' smoke detectors can be monitored for alarm and trouble conditions The SK-MINIMON can be mounted in a sin ang junction box directly behind the monitored device. Its small size light weight allow it to be installed without rigid mounting requireme INSTALLATION The SK-MINIMON can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. FEATURES & BENEFITS • Single contact monitor • Rotary address • SK-Minimon support switches for fast for Class B (Style B) installation contact monitor wiring • UL Listed • Small and lightweight • CSFM Listed size allows for flexible . FM Approved mounting options I as SK-MINIMON SK-MINIMON Technical Specifications PHYSICAL Dimensions: 2.75" W x 1.3" H x 0.5" D Weight: 1.2 oz (37 g) ELECTRICAL Operating Voltage: 15 — 32VDC SLC Standby and Alarm Current: 350 µA End -of -Line Resistance:47Kf2 Initiating device circuit wiring resistance: 1,500f2 max SLC loop resistance: 40Q max Wire Length: 6" min. ENVIRONMENTAL Operating Temperature: 32°F — 120°F (0°C — 49°C) Humidity: 10%— 93% non -condensing For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 ORDERING INFORMATION SK-MINIMON: Mini monitoring module COMPATIBILITY The SK-MINIMON is compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency voice system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system Doc 350133 1 Rev G 1 11/17 © 2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit www.sitentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight°, System Sensor' and Honeywell' are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We tryto keep our product information up -to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. Honeywell SILENT' KNIGHT Honeywell ®SILENT' I acir SK-PULL-SA / SK-PULL-DA Intelligent Pull Stations I The SK-PULL-SA is a single action pull station requiring only one motion to activate the station. The SK-PULL-DA is a dual action pull station requiring two motions to active the station. The SK-PULL-SA and SK-PULL-DA are for use with Honeywell Silent Knight Series fire control panel (FACP). Extremely easy to operate, the SK-PULL-DA and SK-PULL-SA provide a fast and practical means of manually initiating e alarm signal. The FACP recognizes each manual pull station by its ific address saving precious seconds in determining the location of an a INSTALLATION The SK-PULL-SA and SK-PULL-DA can be surface mounted to an SB-1/0 surface back box or semi -flush mounted on a standard single -gang with a minimum depth of 2.13"(5.40 cm) or double gang or 4" (10.61 cm) square electrical box. You can also use the optional (System Sensor' PN BG-TR) trim ring if the station is being semi -flush mounted. 1k FEATURES & BENEFITS • Installer can open station without causing an alarm condition • Dual -color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets ADA requirement for 5 lbs maximum pull force to active Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) • Shell, door, and handle molded from durable LEXAN° SK-PULL-SA SK-PULL-DA • Reliable analog communications for trouble -free operation • Braille text on station handle • Rotary address switches for fast installation • Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled • UL Listed, including UL 38, Standard of Manually Actuated Signaling System • CSFM Listed • MEA Listed SK-PULL-SA / SK-PULL-DA Technical Specifications For a complete listing of all compliance approvals and certifications, please visit PHYSICAL ORDERING INFORMATION www.sitentknight.com. Dimensions: 5.5" H x4" W x 1.45" D (14 x 10.2 x SK-Pull-SA: Single Action Pull Station 3.7cm) SK-Pull-DA: Dual Action Pull Station and e the Windows Logo are theWi down Logo HousingMaterial: LEXAN of carbonate resin P Y registered trademarks Bi-Colored LED: ACCESSORIES or trademarks of Blinking Green: Normal BG-TR: Optional trim ring. Microsoft Corporation. Steady Red: Alarm SB-1/0: Surface backbox, indoor/outdoor. Silent Knight®, System Switch: Single pole, single throw (SPST) normally * Unless otherwise noted, specifications apply to Sensor' and Honeywell' open (N/O) switch which closes upon activation of SK-Pull-SA and SK-Pull-DA are registered the pull station trademarks of Honeywell COMPATIBILITY International, Inc. ELECTRICAL The SK-PULL-SA AND SK-PULL-DA are This document is not Operating Voltage: 15 — 32VDC compatible with the following Honeywell Silent intended to be used for SLC Standby and Alarm Current: 350µA Knight fire alarm control panels: installation purposes. We Wire Gauge: Up to 12AWG (3.1 mmz) 6820: Addressable fire alarm control panel tryto keep our productinformation up -to 6820EVS: Addressable fire alarm control panel date and accurate. We ENVIRONMENTAL with an emergency voice system. cannot cover all specific Operating Temperature: 320F — 120°F (0°C — 6808: Addressable fire alarm control panel applications or anticipate 49°C) 6700: Addressable fire alarm control panel all requirements. All specifications are subject Humidity: 10% — 93% non -condensing 5700: Addressable fire alarm control panel to change without notice. 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel caIt 80 -446 6444. call 800-446-6444. 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford, CT 06472 Doc 350135 1 Rev E 1 11/17 SILENT 13 800-328-0103 © 2017 Honeywell International Inc. EMGHT Honeywell ®SILENT' IcNaGIF SK-RELAY Intelligent Relay Module The SK-RELAY is an addressable relay mod for use with Honeywell Silent Knight Series fire alarm control panels (FA T. The SK-RELAY allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. The SK-RELAY contacts can be used for vir ly any normally open or normally closed application. Each SK-REL programmed with a unique signaling line circuit (SLC) loop address. W an event occurs that controls the SK-RELAY, the relay is triggere y the FACP. INSTALLATION The SK-RELAY mounts directly into a 4" sq# electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor' PN SMB500) is available from Silent Knight. FEATURES & BENEFITS • Two sets of Form C contacts • Rotary address switches for fast installation • Contacts are rated for a variety of amps (see Specifications) • Panelcontrolled status LED that flashes green in normal state and is solid red in alarm • Relay programming is completely flexible — can be mapped to zone conditions • Polling LED visible through the cover plate • SEMS screws for easy wiring • UL Listed Ht SLL1:1 I' I(N (Arl' SK-RELAY SK-RELAY Technical Specifications For a complete listing of all compliance approvals and certifications, please visit PHYSICAL ORDERING INFORMATION www.sitentknight.com. 4.675" H x 4.275" W x 1.4" D SK-RELAY: Relay Module Shipping Weight: 6.3 oz (196 g) Microsoft, Windows, and ACCESSORIES. the Windows Logo are registered trademarks ELECTRICAL SM13500:4" Square Surface Mount Electrical Box or trademarks of Operating Voltage:15 — 32 VDC CB500:Module Barrier Microsoft Corporation. End -of -Line Resistance: Not used Silent Knight®, System SLC Standby &Alarm Current:.255mA max t?a COMPATIBILITY Sensor' and Honeywell' 24VDC (one communication every 5 sec with LED The SK-RELAY is compatible with the following are registered enabled) Honeywell Silent Knight fire alarm control panels: trademarks of Honeywell 6820: Addressable fire alarm control panel International, Inc. ENVIRONMENTAL 6820EVS: Addressable fire alarm control panel This document is not Operating Temperature: 320F — 120oF (OoC — with an emergency mass notification system. intended to be used for 490C) 6808: Addressable fire alarm control panel installation purposes. We Humidity: 10% — 93% non -condensing 6700: Addressable fire alarm control p anel infortrytokeep our product information up -to RELAY CONTACT RATINGS 5700: Addressable fire alarm control panel date and accurate. We 3.OA 30VDC resistive 5808: Addressable fire alarm control panel cannot cover all specific applications or anticipate 0.9AC 110VDCresistive 5820XL: Addressable fire alarm control panel all requirements. All 0.9A @ 125VAC resistive 5820XL-EVS: Addressable fire alarm control panel specifications are subject with an emergency mass notification system. to change without notice. 0.5A 125VAC inductive (PF=.35) C 0.7A C 75VAC inductive (PF = .35) For Technical Support, call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products byvisiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell N o rthfo rd, CT 06472 Doc 3501271 Rev GI 11/17 SILENT 13 800-328-0103 © 2017 Honeywell International Inc. EMGHT 4,�� SYSTEM SWIFT " Base The System Sensor SWIF1O Wireless system offers an AV base to support L-Series devices in wireless installations. Features • Wireless installation • Class A mesh network • Addressable code wheels • Commercial applications • Listed to UL 464, UL 1638, UL 1971, ULC S525, and ULC S526 • Frequency hopping • Bi-Directional Communications Agency Listings SIGNALING FM 0; LISTED 54011 3062564 7300-1653:0513 The SWIFT AV bases (WAV-CRL, WAV-CWL, WAV-RL and WAV-WL) are intended for use with compatible System Sensor L-Series AV notification appliances to meet a comprehensive range of notification requirements. The AV Base provides power for the audio and visual signals and supports wireless communication with the Fire Alarm Control Panel (FACP). The L-Series AV notification appliance is mounted directly to the wireless AV base allowing flexibility in color, placement and signal output. Power is supplied through two sets of 4 batteries — one set provides power for wireless communication, and the other set provides power for the notification appliance's audio and/or visual signal. Battery life of the wireless portion is UL listed for at least 2 years. Battery life for the AV set of batteries depends upon the activation time and output level of the audio or visual signal. The AV base boosts output voltage to support 24VDC options on connected devices. The SWIFT synchronization module (W-SYNC) can be used to provide audio and visual synchronization between SWIFT notification appliances and System Sensor wired notification appliances. The wireless synchronization module operates from 24V power with supplemental battery support and communicates through the mesh network to the gateway and FACP. Synchronization is only available with notification appliances that use the System Sensor synchronization protocol. Synchronization of the SWIFT notification appliances within a single mesh network is inherent in the wireless system and a wireless synchronization module is not needed. The W-SYNC also provides wireless control and monitoring of a Notification Appliance Circuit (NAC) expander or power supply. SWIFT SYSTEM OVERVIEW The SWIFT Smart Wireless Integrated Fire Technology wireless system offers intelligent (addressable) devices which provide secure, reliable communication to the Fire Alarm Control Panel (FACP) across a Class A mesh network. Wireless devices create an opportunity for applications where it is costly (concrete walls/ceilings, buried wires), obtrusive (surface mount conduit), or possibly dangerous SPDS902-01 • 7/29/2020 • Page 1 (asbestos) to use traditional wired devices. It allows fast installation or through one or more intermediate devices. Once an initial mesh for time -critical situations and provides the flexibility to add wireless network is formed, mesh restructuring automatically occurs to find onto wired systems for retrofit installations. Both wired and wireless the strongest paths possible within the network. devices can be present on the same FACP for an integrated solution. The mesh network within the SWIFT system creates a child -parent relationship between the devices so that each device has two parents providing a second path for communications on every device. If one device can no longer operate for any reason, the rest of the devices can still communicate with each other, directly Specifications The SWIFT system also engages frequency hopping to prevent system interference whether intentional or accidental. Each device complies with part 15 of the FCC rules: 1) The device may not cause harmful interference and 2) The device must accept any interference received including interference that may cause undesired operation. Dimensions (Ceiling) Diameter 7.4" (19 cm); Depth 1.6" (4 cm) Weight (Ceiling): 20.0 oz (567 g) installed with 8 batteries Dimensions (Wall) Height 6" (15 cm); Width 5.1" (13 cm); Depth 1.6" (4 cm) Weight (Wall) 17.6 oz (499 g) installed with 8 batteries Electrical Specifications RF Operating Voltage Range 3.3 VDC RF Maximum Current Draw 5 mA (LED On) RF Operating Voltage 12 VDC AV Output, Operating Voltage 24 VDC (nominal) AV Maximum Standby Current 6.5 mA AV Maximum Alarm Current 550 mA Standby Current 210 pA @ 3.3 VDC (LED blink enabled) Maximum Transmit RF Power 17 dBm Radio Frequency Range 902-928 MHz Operating Humidity Range 10% to 93% Relative Humidity, Non -condensing Operating Temperature Range 32°F to 120°F (0°C to 49°C) Battery Type 8 Panasonic CR123A or 8 Duracell DL123A Battery Life RFbatteries: 2 year minimum. AV batteries: See Table 2 for AV battery life. Battery Replacement Replace during annual maintenance or when TROUBLE BATTERY LOW displays. Model Model Battery Life (Hour, Minutes), per Candela Setting Type 15 cd 30 cd 75 cd 95 cd 110 cd 115 cd 135 cd 150 cd 177 cd 185 cd Wall 127h 23m Chime -only Ceiling Wall 31 h 51 m Horn -only Ceiling Wall 20h 44m 14h 09m 8h 20m 7h 22m 6h 02m — 5h 11 m — — 4h 01 m Strobe-onl y Ceiling 21 h 45m 14h 09m 8h 02m 6h 39m — 5h 39m — 4h 43m 3h 57m — Wall 18h 12m 12h 55m 7h 58m 6h 31 m 5h 18m — 4h 26m — — 3h 37m Chime Strobe Ceiling 18h 35m 12h 44m 7h 41 m 6h 28m — 5h 24m — 4h 29m 3h 45m — Wall 16h 31 m 12h 03m 7h 22m 6h 17m 5h 30m — 4h 33m — — 3h 38m Horn -Strobe Ceiling 12h 34m 9h 54m 6h 14m 5h 24m — 4h 46m — 4h 07m 3h 31 m — Low-Freq. Wall 8h 15m Sounder -Only Ceiling 8h 15m Low-Freq. Sounder- Strobe Wall — 9h 6m 7h 45m 5h 39m 4h 56m 4h 54m 4h 12m — — 3h 18m NOTE: Battery life will decrease using continuous tone or other coded patterns and under non -ambient environmental conditions. SPDS902-01 - 7/29/2020 - Page 2 Compatible Equipment Note: ULC-listed models have all required languages. Model Model Model Model (UL listed) (ULC listed) Description (UL listed) (ULC listed) Description CHRL CHWLA* Chime Red Wall P2WL-LF P2WLA-LFt 520Hz Sounder/Strobe White CHSCWL CHSCRLA* Chime/Strobe Red Ceiling Wall CHSCRLA-E Chime/Strobe Red Ceiling, P2WL-P P2WLA-P Horn Strobe 2-wire White Wall, English Plain CHSCRLA-F Chime/Strobe Red Ceiling, P2WL-SP — Horn Strobe 2-wire White Wall, French Fuego CHSCWL CHSCWLA* Chime Strobe White Ceiling PC2RL PC2RLA* Horn Strobe 2-wire Red Ceiling CHSCWLA-E Chime/Strobe White Ceiling, PC2RLA-E Horn/Strobe 2-wire Red English Ceiling, English CHSCWLA-F Chime/Strobe White Ceiling, PC2RLA-F Horn/Strobe 2-wire Red French Ceiling, French CHSWL CHSWLA* Chime Strobe Red Wall PC2WL PC2WLA* Horn Strobe 2-wire White CHSWLA-E Chime/Strobe Red Wall, Ceiling English PC2WLA-E Horn/Strobe 2-wire White CHSWLA-F Chime/Strobe Red Wall, Ceiling, English French PC2WLA-F Horn/Strobe 2-wire White CHSWL CHSWLA Chime Strobe White Wall Ceiling, French CHSWLA-E Chime/Strobe White Wall, SCRL SCWLA* Strobe Red Ceiling English SCWLA-E* Strobe Red Ceiling, English CHSWLA-F Chime/Strobe White Wall, SCWLA-F Strobe Red Ceiling, French French SCWL SCWLA* Strobe White Ceiling CHWL CHWLA Chime White Wall SCWLA-E Strobe White Ceiling, English HCRL-LF HCRLA-LFt 520Hz Sounder Red Ceiling SCWLA-F Strobe White Ceiling, French HRL HRLA Horn Red Wall SCWL-CLR- — Stobe White Ceiling Clear HRL-LF HRLA-LFt 520Hz Sounder Red Wall ALERT Lens Alert HCWL-LF HCWLA-LFt 520Hz Sounder White Ceiling SRL SRLA* Strobe Red Wall HWL HWLA Horn White Wall SRLA-E Strobe Red Wall, English HWL-LF HWLA-LFt 520Hz Sounder White Wall SRLA-F Strobe Red Wall, French P2RL P2RLA* Horn/Strobe 2-wire Red Wall SRL-P SRLA-P Strobe Red Wall, Plain P2RLA-E Horn/Strobe 2-wire Red Wall, SRL-SP — Strobe Red Wall, Fuego English SWL SWLA* Strobe White Wall P2RLA-F Horn/Strobe 2-wire Red Wall, SWLA-E Strobe White Wall, English French SWLA-F Strobe White Wall, French P2RL-LF P2RLA-LFt 520Hz Sounder/Strobe Red SWL-ALERT — Strobe White Wall, Amber Lens Wall SWL-CLR- — Strobe White Wall, Clear Lens P2RL-P P2RLA-P Horn Strobe 2-wire Red Wall, ALERT Plain SWL-P SWLA-P Strobe White Wall. Plain P2RL-SP — P2WL P2WLA P2WLA-E P2WLA-F Horn Strobe 2-wire Red Wall, Fuego *Bilingual Canadian model Horn Strobe 2-wire White Wall tAdd suffix "E" for English, "-F" for French, and "-P" for plain version (no Horn/Strobe 2-wire White Wall, text). English Horn/Strobe 2-wire White Wall, French SPDS902-01 • 7/29/2020 • Page 3 Ordering Information WAV-CRL Wireless AV base, ceiling, red WAV-CWL Wireless AV base, ceiling, white WAV-RL* Wireless AV base, wall, red WAV-WL* Wireless AV base, wall, white W-SYNC Wireless Sync Module W-BATCART Wireless battery cartridge, 10-pack *Note: WAV-RL & WAV-WL are compatible with wall -mount L-Series devices manufactured after 26 April 2019 (date code 9045 and later). WAV-CRL and WAV-CWL are compatible with all ceiling -mount L-Series devices. Accessories W-BATCART Wireless battery cartridge 0 ,► XL is l mf ,r -ir -*r System Sensor® and SWIFT® are registered trademarks of Honeywell International, Inc. Duracell® is a registered trademark of Duracell U.S. Operations Inc. Panasonic® is a registered trademark of Panasonic Corporation. SYSTEM ©t to c System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notice. Visit systemsensoccom SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 or current product information, 02-0ingthe latestversion ofthis data sheet. SPDS902-01 • 7/29/2020 4,�� SYSTEM Indoor Selectable - Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only Agency Listings SIGNALING & F M LISTED APPROVED 55512 FM approved except 7125-1653:0504 54011 for ALERT models 7135-1653:0503 3057383 The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVDS868-02 - 12/01/2017 • Page 3 L-Series Specifications General L-Series ceiling -mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double - gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit'" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling -Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02. 12/01/2017 • Page 2 UL Current Draw Data RIJNMFVf1RjM- T.i. nja;' 1IFFSL*Irii1MECi11 L max. 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16--,33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non -Temporal High 43 47 54 95 N/A 134 164 Non -Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non -Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.11K Non -Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non -Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non -Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.11K Non -Temporal High 108 135 179 200 225 255 289 3.1 K Non -Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data StrobeHorn .: 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 AVDS868-02 • 12/01/2017 • Page 3 L-Series Dimensions 0.83" di (173 n 2.47" (62.7 mm) 1.37" (34.8 min) Ceiling -Mount Horn Strobes A0545-00 A0494-01 6.92" r+— (175. Ceiling Surface Mount Back Box 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire, Horn Strobe, Red SCRL Strobe, Red PC2WL 2-Wire, Horn Strobe, White SCWL Strobe, White PC4RL 4-Wire, Horn Strobe, Red SCWL-CLR-ALERT Strobe, White, ALERT PC4WL 4-Wire, Horn Strobe, White Accessories 2.5' (64 mm) O A0546-00 TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White For a ceiling -listed horn -only device, see AVDS865 "Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications". 1-01 SYSTEM ©t to c System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notice. Visit systemsensoccom SENSOR" Phone: 800-SENSOR2 • Fax: 630-377-6495 or current product information,6,-02ngthe latestversion ofthisdata sheet. AVDS868-02 • 12/01/2017 4,�� SYSTEM Outdoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field -selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from —40°F to 151 °F • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Listed for ceiling or wall mounting Agency Listings SIGNALING O L F M MEA 7300-1653:187 (outdoor strobes) LISTED approved 7125-1653:188 (horn strobes, S4011 (chimes, horn strobes, horns) APPROVED pp chime strobes) S3593 (outdoor and alert strobes) 3N,'F79 MEA452-05-E 7135-1653:189 (horns, chimes) AIL 0 pf'r S y s t e m S e n s o ar SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40oF to 151 °F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field -selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in -and - out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock -outs located on the back eliminate the need to drill holes for screw -in mounting. Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch knock -outs at the back. A screw -in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•CircuitT" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options shall be set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non -coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature -40°F to 151 °F (-40oC to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7-W x 2.5-D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7-L x 5.1-W x 2.0-D (145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) MIMEr "MIRIMM, I 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB 8-17.5 Volts 16-33 Volts DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non -Temporal High 57 56 69 75 95 NA NA 181 176 Non -Temporal Medium 42 50 60 69 110 NA NA 202 195 Non -Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 Max. Current Draw (mA RMS), 2-Wire Horn Strobe,UL ..Candela 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non -Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 85 95 110 166 189 208 216 Non -Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current •Strobe, DC Input High 16-33 Volts 135 150 177 Candela 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 wit 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn and Horn Strobe Output •8-17.5 candela ratings must be reduced in accordance with 16-33 24-Volt Nominal this table. S h S d Volts Volts Reverberant Anechoic StrobeOutput Listed Candela Candela rating at —40°F 15 Do not use below 32°F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 1185 c Position oun Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDS01201 rAlert Advance Diagrams 2.5" 3„ Wall -Mount Horn Strobes IMP U erproof Back Box Wall -Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Wall Horn Strobes P2RK`t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK't 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK"t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK•t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK"t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK't Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK•t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: Add '-P" to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. t Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. f_ SYSTEM ©t to change System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Produc specifications subject02SysmSentnotice. Visit systemsensoccom SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 or current product information,DS01 01.3/atestversionofthisdaasheet. AVDS01201 • 3/12