APPROVED BLD2022-0106+Plumbing_Plan+1.26.2022_8.30.10_AM+2641944 (2)1-0 L14014:�_1� PLUMBING PIPING ABBREVIATIONS VICINITY MAP N NN N r- SYMBOL ABBR DESCRIPTION AAV AUTOMATIC AIR VENT 45° ELBOW < 45' DOWN 90° ELBOW 0 UP C DN DOWN AD ACCESS DOOR IN CEILING AD ACCESS DOOR IN WALL ALIGNMENT GUIDE ANCHOR i BV BALL VALVE BFV BUTTERFLY VALVE CHK CHECK VALVE CIRCUIT SETTER FLANGE FLEX GAS COCK GLOBE VALVE GV GATE VALVE PRV PRESSURE REDUCING VALVE RV RELIEF VALVE SV SOLENOID VALVE NEEDLE ISOLATION VALVE BREAK E CAP CENTERLINE xx'-X CL-EL CENTERLINE OF PIPE ELEVATION DETAIL CALL -OUT X-X X SECTION CALL -OUT L-*-* I SP*-* Do FLOW ARROW iE xx'-xx" IE INVERT PIPE ELEVATION 9fIPE PER FOOT PITCH "R" FOR RISE, "D" FOR DROP, IN DIRECTION OF ARROW METER PLUG POC POINT OF CONNECTION PG PRESSURE GAUGE ROLLING 45 DOWN REDUCER <1— REDUCING CONCENTRIC 17:�_ REDUCING ECCENTRIC Ox DRAWING NOTE DESIGNATION SLEEVE lei TEE DOWN 4— TEE A TH THERMOMETER T TEMPERATURE PRESSURE TEST PLUG WC -I I EQUIPMENT OR FIXTURE TAG, IDENTIFIES TYPE AND UNIQUE IDENTIFIER - REFER TO SCHEDULES OOP xx'-xx" BOP BOTTOM OF PIPE ELEVATION OP xx'-xx" TOP TOP OF PIPE ELEVATION U UNION VALVE IN PIPE RISE OR DROP ~ STR WYE TYPE STRAINER 'Sy~ WYE TYPE STRAINER WITH VALVE �OxJ AND HOSE END WITH CAP VB VACUUM BREAKER VENTURI SYMBOL ABBR DESCRIPTION CD — CD CONDENSATE DRAIN —Tl+-- DOUBLE COMBO Ti COMBO LEFT —tT+-- COMBO LEFT W/ 1/4 BEND Tz COMBO LEFT W/ 1/8 BEND is COMBO RIGHT COMBO RIGHT W/ 1/4 BEND COMBO RIGHT W/ 1/8 BEND I� CO CLEANOUT CW DOMESTIC COLD WATER D D INDIRECT DRAIN LINE DCBP DCBP DOUBLE CHECK BACKFLOW PREVENTER — DET — DET DETERGENT OO DRAIN 0 FCO FLOOR CLEANOUT GWY GWY GRAY WATER — GRW — GRW GREASE WASTE — GW — GW GARAGE WASTE HB HOSE BIBB IID� HOSE END DRAIN VALVE HW DOMESTIC 120° F HOT WATER —140 — HW DOMESTIC 140° F HOT WATER HWC DOMESTIC 120° F HOT WATER CIRCULATION 140 HWC DOMESTIC 140° F HOT WATER CIRCULATION IR IR IRRIGATION LINE IW IW INDIRECT WASTE FLONG RADIUS 90 — NP — NP NON -POTABLE ORD OVERFLOW ROOF DRAIN — ORL — ORL OVERFLOW RAIN WATER LEADER C}C+— P-TRAP PC PC PUMPED CONDENSATE PW PW PUMPED WASTE OO RD ROOF DRAIN RPBP RPBP REDUCED PRESSURE BACKFLOW PREVENTER — RWL — RWL RAIN WATER LEADER, ABOVE GROUND SD SD STORM DRAIN SS SS SANITARY SEWER T T TEMPERED WATER TP TP TRAP PRIMER TR TR TEMPERED WATER RETURN V VENT AIL VTR VENT THRU ROOF W W WASTE HY WALL HYDRANT WHA WATER HAMMER ARRESTER WYE LEFT WYE RIGHT SYMBOL ABBR DESCRIPTION BFW BFW BOILER FEED WATER ---- 0 BUCKET STEAM TRAP CA— CA CONTROL AIR , COMPRESSED AIR CHR CHR CHILLED WATER RETURN CHS CHS CHILLED WATER SUPPLY CR— CR CONDENSER WATER RETURN CS— CS CONDENSER WATER SUPPLY m FLOAT AND THERMOSTATIC STEAM TRAP FOR— FOR FUEL OIL RETURN FOS FOS FUEL OIL SUPPLY — FOV— FOV FUEL OIL VENT G G NATURAL GAS GLR GLR GLYCOL RETURN GLS GLS GLYCOL SUPPLY — HCR— HCR HIGH PRESSURE CONDENSATE RETURN HG— HG HOT GAS —HPS— HPS HIGH PRESSURE STEAM HWR HWR HEATING WATER RETURN — HWS— HWS HEATING WATER SUPPLY — LCR — LCR LOW PRESSURE CONDENSATE RETURN LPS LPS LOW PRESSURE STEAM MAV MANUAL AIR VENT — MCR— MCR MEDIUM PRESSURE CONDENSATE RETURN MG MG MEDIUM PRESSURE NATURAL GAS MPS— MPS MEDIUM PRESSURE STEAM — PCR— PCR PUMPED CONDENSATE RETURN RL— RL REFRIGERANT LIQUID RS— RS REFRIGERANT SUCTION CONTROLS PI PI PRESSURE INDICATOR TI TI TEMPERATURE INDICATOR Ts TS TEMPERATURE SENSOR ALL WOR S BJECT TOFE D INSPECT O FOR CODE CO IANCE APPROVE PLANS MUST ON JOB SIT ADA AMERICAN DISABILITY ACT AD ACCESS DOOR, AREA DRAIN AFF ABOVE FINISHED FLOOR CB CATCH BASIN CO2 CARBON DIOXIDE CID CHANGE PROPOSAL DF DRINKING FOUNTAIN EWC ELECTRIC WATER COOLER FD FLOOR DRAIN FS FLOOR SINK LAV LAVATORY LA LAB AIR LV LAB VAC LCW LAB COLD WATER LHW LAB HOT WATER LHWC LAB HOT WATER RECIRC LW LAB WASTE LCW LAB COLD WATER NIC NOT IN CONTRACT NTS NOT TO SCALE REV REVISION RFI REQUEST FOR INFORMATION SS STAINLESS STEEL TYP TYPICAL TW TEPID WATER UR URINAL UNO UNLESS NOTED OTHERWISE VTR VENT THROUGH ROOF GENERAL NOTES 1. THE PLUMBING SCOPE OF WORK SHALL INCLUDE WORK INDICATED ON DRAWINGS. 2. VERIFY EXISTING CONDITIONS BEFORE COMMENCING WORK ON AN EXISTING PLUMBING SYSTEM. 3. VERIFY LOCATIONS AND DIMENSIONS OF EQUIPMENT AND COORDINATE WORK PRIOR TO START OF CONSTRUCTION 4. COORDINATE PLUMBING WORK WITH OTHER TRADES TO INSURE PROPER AND ADEQUATE INTERFACE OF THEIR WORK WITH THE WORK OF THIS CONTRACTOR. INSTALL PLUMBING WORK AS HIGH AS POSSIBLE, TIGHT TO STRUCTURE ABOVE, OR AS SLOPING ALLOWS. 5. ELEVATIONS ARE REFERENCED FROM FINISHED FLOOR, UNLESS NOTED OTHERWISE. 6. THE PLUMBING DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT ATTEMPT TO SHOW ALL REQUIRED OFFSETS. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR CONSTRUCTION DETAILS. 7. PROVIDE NEC CODE MINIMUM HORIZONTAL AND VERTICAL WORKING CLEARANCES FOR ELECTRICAL PANELS AND EQUIPMENT. OFFSET PLUMBING WORK AS REQUIRED. 8. COORDINATE EXACT LOCATIONS OF MOUNTING HEIGHTS OF PLUMBING FIXTURES WITH CASEWORK AND ARCHITECTURAL DRAWINGS, REFERENCE ARCHITECTURAL. 9. REFERENCE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR FLOOR SLOPING OR ROOM THRESHOLD AT FLOOR DRAINS 10. PLUMBING DRAWINGS SHOW APPROXIMATE LOCATIONS FOR FLOOR DRAINS. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS IN MECHANICAL EQUIPMENT AREAS, COORDINATE LOCATIONS OF THE FLOOR DRAINS WITH HOUSEKEEPING PADS AND EQUIPMENT DRAIN LOCATIONS. 11. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL CONSTRUCTION, INCLUDING BUT NOT LIMITED TO: EQUIPMENT HOUSEKEEPING PADS, PENETRATION DETAILS, FLASHING AND SEALING DETAILS AND OTHER ELEMENTS OF GENERAL CONSTRUCTION. PLUMBING CONTRACTOR TO COORDINATE THE SIZE AND LOCATION OF EQUIPMENT HOUSEKEEPING PADS WITH APPROVED EQUIPMENT SUBMITTALS. 12. OBTAIN APPROVAL OF STRUCTURAL ENGINEER PRIOR TO PENETRATION OF ANY STRUCTURAL ELEMENT, IF PENETRATION IS NOT SHOWN ON STRUCTURAL DRAWINGS. 13. PROVIDE SEISMIC RESTRAINTS AND ANCHORAGE PER SMACNA AND THE BUILDING CODE FOR PLUMBING SYSTEMS, REFERENCE STRUCTURAL. PLUMBING CONTRACTOR SHALL INDICATE IF A DEFERRED SUBMITTAL FOR PERMITTING IS REQUESTED. SENERAL CONTRACTOR SHALL PROVIDE CUTTING, FRAMING, PATCHING, SEALING AND PAINTING OF WALLS, ILING AND FLOOR OPENINGS. THIS INCLUDES OPENINGS THOUGH AREA SEPARATION WALLS. LEGAL DESCRIPTION THAT POR OF N 1/2 OF NE 1/4 OF SW 1/4 LY ELY OF RR R/WS LESS CO RD & LESS RD (ROW DEDICATION PER CITY OF KENT REC #20190918000293) PARCEL NUMBER 1222049018 GOaAI&RLVJ11111010 NORTH ARROW PLUMBING DRAWING INDEX SHEET # DESCRIPTION P0.01 LEGEND, DRAWING INDEX, VICINITY MAP AND GENERAL NOTES P0.02 PLUMBING MATERIALS, SCOPE, AND CODE SUMMARY PD2.01 LEVEL SEVEN - PLUMBING DEMO PLAN P2.01 LEVEL SEVEN - PLUMBING PLAN P4.01 PLUMBING DETAILS Medical gas reports to be provided to City Inspector prior to final inspection. City Of Edmonds Building Department Work MED GAS OUTLETES Address 21601 76TH AVE W Owner SWEDISH BIRTHING CENTER Approved Date 02/08/2022 Building Official Erica Carter Permit Number BLD2022-0106 Approved by Fire 02/09/2022 AFM /<_/F1 tt °rer RECEIVED Jan 27 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Legal: THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. H W a cG 0 0 CAI Q O W M O Z H m CO O o O CM JO O W rn LL ti Q Q o ti ~ UHco ■ C/� Z 0 LU Q r 0 p �02 o 0 °' N W o LU) Z J LJ Z a ��- FO Z _U V �U W 0 V O\. Z Cie / Z V J G/ST F SG: S�0 NA L End Drawn By UMC Checked By RVK Original Issue Date 1/21/2022 Job No. 8565 Scale NONE Sheet No PO.01 TRADE CATEGORY BOD CRITERIA INPUT SOURCE ADDITIONAL SOURCE INFO (DATE, MEETING, E-MAIL,ETC) CODE BASIS FOR PROJECT MECHANICAL BUILDING CODE 2018 INTERNATIONAL BUILDING CODE (IBC) AND ICC/ANSI A117.1-09, ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES, WITH STATE AMENDMENTS AHJ MECHANICAL ELECTRICAL CODE 2018 NATIONAL ELECTRICAL CODE WITH LOCAL AMENDMENTS AHJ MECHANICAL ENERGY CODE 2018 WASHINGTON STATE ENERGY CODE WITH LOCAL AMMENDMENTS AHJ MECHANICAL FIRE CODE 2018 INTERNATIONAL FIRE CODE WITH STATE AND LOCAL AMMENDMENTS AHJ MECHANICAL FUEL GAS CODE 2018 INTERNATIONAL FUEL GAS CODE WITH STATE AND LOCAL AMMENDMENTS AHJ MECHANICAL MECHANICAL CODE 2018 INTERNATIONAL MECHANICAL CODE WITH STATE AND LOCAL AMMENDMENTS AHJ MECHANICAL FACILITIES GUIDELINES 2018 FACILITY GUILDELINE INSTITUTE (FGI), GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITAL AND HEALTHCARE FACILITIES AHJ PLUMBING PLUMBING CODE 2018 UNIFORM PLUMBING CODE WITH STATE AND LOCAL AMMENDMENTS AHJ LEED NO REQUIREMENT FOR LEED CERTIFICATION REFERENCE SPECIFIC TRADE DRAWING SET TO VERIFY CODE COMPLIANCE PATH ELECTRICAL, ARCHITECTURAL, FIRE PROTECTION N (D N O o N PROJECT NAME: SMCE - 7TH FLOOR BIRTHING MED GAS RMS 704-706 N PLUMBING SCOPE OF WORK: DEMO MED GAS SERVICES TO CEILING SPACE SHUTDOWN MED GAS AND INSTALL VALVES SO EXISTING ROOMS HAVE SERVICE DURING CONSTRUCTION INSTALL BEACON MEDAES SERIES B CONCEALED MED GAS OUTLETS AS SHOWN ON PLANS U co a� 0 a� CG W a ce O 0 W tnn Sn z aaaaaaa 'Q V MED CAL GAS PPE S S o �'3 Z GC m CO M E D CAS GAS OUTLETS o cr, 0 O O Wrn J L �: Q ¢ = o � H (� ■ C/� Z Lu Q T O p �02 U L� U (O o o y ° NW c o O cn L LJ 0 O U Z Q W E O cU/) U E J Q W 5¢ V Z m J WAS 4778 �0'<\ �F0/STER FSs/O NA L Drawn By UK Checked By RVK Legal: THIS DRAWING AND THE DESIGN Original Issue Date 12/21/2022 RECEIVED HEREIN ARE THE PROPERTY OF Jan 27 2022 UNIVERSITY MECHANICAL Job No. 8565 CONTRACTORS, INC. FOR THEIR CITY OFEDMONDS USE IN CONSTRUCTION OF THIS DEVELOPMENT SERVICES Scale NONE DEPARTMENT PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE Sheet No. WRITTEN CONSENT OF UNIVERSITY PO.02 MECHANICAL CONTRACTORS, INC. MED GAS PIPE SIZE TO OUTLETS 02 i/2 MV 3/4 MA 1/2 MED GAS PANDA BED oz � i MV 1 MA 1 1 MARK O O U M (_ D_ _00 V) Z r-O W Y Z m N N J O W N Q � U_ N MEDICAL GAS FIXTURE SCHEDULE TAG LT-1 DESCRIPTION SERVICE 02, MED AIR, MED VAC LOCATION WALL MOUNTED OUTLET CONFIGURATION TRIPLE EQUIPM NT MANUFACTURER BEACON MEDAES MODEL SERIES B TRIM OPTION OUTLET ROUGH IN ASSEMBLY LABORATORY VACUUM ITEMS 6" And Smaller PIPE MATERIALS Pipe, Copper Type L 688 JOINT TYPE Swt —Lead—Free Solder, Silvabrite 100 FITTING MATERIAL Wrot Copper 616.22 FLANGES 150� Press Companion Flange, Cast Bronze 616.24 GASKETS Gasket, 1/8" Non —Asbestos Ring, 616.21 BOLT TYPE Bolts, A307 Grade B Plated VALVES BALL VALVE: 150# Ball Valve, Two —Piece Full Port SP-110 Brnz Swt —Apollo 77C-200 ZONE VALVE BOX ASSEMBLY Zone Valve Box Assembly —Beacon Medaes SPECIALTIES PRESSURE GAUGE Pressure Gauge —Beacon Medaes NOTES: 1 —Use "Branch Takeoff" in lieu of fitting if branch piping is 1 sizes less than main or more. Example; Use 1-1/2" T—Drill in lieu of 2"x1-1/2" Tee. OXYGEN AND LAB AIR ITEMS 6" And Smaller PIPE MATERIALS Pipe, Copper Type L 6819 (Cleaned And Bagged) JOINT TYPE Brz — AWS A5.8, BAg-1 or BAg-2 Silver Solder FITTING MATERIAL Wrot Copper 616.22 (Cleaned And Capped) FLANGES 150# Press Companion Flange, Cast Bronze 616.24 (Cleaned And Bagged) GASKETS Gasket, 1/8" Non —Asbestos Ring, 616.21 BOLT TYPE Bolts, A307 Grade B Plated VALUES BALL VALVE: Ball Valve W/ Lockable Handle —Beacon Medaes ZONE VALVE BOX ASSEMBLY Zone Valve Box Assembly —Beacon Medaes SPECIALTIES PRESSURE GAUGE Pressure Gauge —Beacon Medaes NOTES: 1 — 'Use "Branch Takeoff" in lieu of fitting if branch piping is 1 sizes less than main or more. 'Example; Use 1-1/2" T—Drill in lieu of 2"x1-1/2" Tee. 3 v O N v D_ to N / w v 0 U / CO O I O r- co E L N O rn v a� E rn C C L O O t I a� U E U I LO LO 00 m 0 U .21 a I O O Q) C N C C N / N 1 U I U m D_ = CO V Z W Y Z m N N J O W N Q � U_ N EXISTING 3/4" MED VAC - EXISTING 1/2" VED AIR - FKSTING 1/2" 02 — D DEMO EXISTING MED AIR; 02, AND MED VAC SERVICES UP TO COILING SPACE, TYP 1 2 3 4 5 6 7 I I I I I I n v m m m I I I I I I I I I I I I I I a n ♦ m o 0 I I I I I I I I I o O O O I� r ❑ 7r6 II ° II I lJ o i I I ® I ° a ❑ O ❑MJ �I I I � ❑ ❑ ° ❑ ❑ e� I I I I — I I I I I m I I I — LEVEL 7 - PLUMBING DEMO PLAN SCALE: 1 /4"44' — g — C - — — D — — F — — RECEIVED Jan 27 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT NORTH ARROW Legal: THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. W a 0 0 z aaaaaaa Q 0 W CM Z H III m co IC= N 5 O M 0 O O Wrn 0 JLL Q Q o v♦ Z LU p Q s 0 �0� U �/ U coo L o y � 2 o Z Q J 50 L W 0 V Z Cm L .J CL Z W W J W W J N N O o N r- N r- rn 3 v O N a w O U co 0 I 0 r- co E V) O rn E C C L O 0 w -C I a� U E U) I LO LO 00 i 41 0 U .21 a I O 0 rn C C N N 1 U I U m = CO V Z W Y Z m N N J O W N Q � U_ N 1 2 3 4 5 6 I I I N I A— n L I n I — A — — A— v I ♦ I m I m I m I o I AREA OF WORK I 1 � 1 1, Nl- 3/4" MED VAC, 1/2" MED AIR, AND m 1/2" 02 DOWN, CONNECT TO BEACON MEDAES SERIES B CONCEALED MED GAS OUTLETS ON BOTH SIDES OF WALL, REFER TO ARCHITECTURAL LT-1 PLANS FOR OUTLET INFORMATION LT-1 SHUTDOWN MED GAS AND INSTALL I VALVES SO EXISTING ROOMS HAVE GAS, TYP. EXISTING 3/4" MED VAC TI NT EXISTING 1/2" MED AIR EXISTING 1/2" 02 3/4" MED VAC, 1/2" MED AIR, A 1/2" 02 DOWN, CONNECT TO _1 BEACON MEDAES SERIES B CONCEALED MED GAS OUTLETS ON BOTH SIDES OF WALL, REFER TO p NT ARCHITECTURAL PLANS FOR OUTLET 701 INFORMATION NEW 1/2" MED AIR CONNECTION TO RUN TO SOUTH WALL OF ROOM PATIENT 704 Lr-1 CE�- 3/4" MED VAC, 1/2" MED AIR, AND 1/2" 02 DOWN, CONNECT TO BEACON MEDAES SERIES B CONCEALED MED GAS OUTLETS ON WALL, REFER TO ARCHITECTURAL — —PLANS FOR OUTLET INFORMATION— I I — F— I — F— — F — — F— — F— — F — — F— — F— — F — — F I I N I I 10 I Y I m I I I I LEVEL 7 - PLUMBING PLAN SCALE: 1 /4"44' I 0 I I — A — — E — — A — — g — — — D — — E — RECEIVED Jan 27 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT NORTH ARROW Legal: THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. W a O 0 W N U z aaaaaaa Q 0 W Z H Ili m IC= N o O CM O Wrn 0 JO QQ o ti �Hcl) cc) a ■ C/� L Z 0 LLJ Q r 0 U �/ U coo L o y�NW o J V Z 5m L J I Z W W J W W J 0 U �U E N N N O o N N Back to Back outlet Installation Extension Tub Piping Extension Tube System ® Individual - Console Extension Installation outlet ' \ Anchor Tu be Rough -in V) Reducing Adapter Assembl EL Finished Service i 1 0 Wall Identification Label orizonta race ' i Structural Mounting Sur- face Mounting Toggle Bolt a 1 Holes (top and bottom) °�s Mtln Box Structural Mounting Holes �p oo�FR 9 O 1 6a�1>,B °o�FR TOP N co�ST ® °T *Required for Ba 0o R ToP �o�FR more than z aaaaaaa pe�RoT No, three ganged y w a2 "84e�,, a assemblies -cc ® o� (furnished byLU o oo�E� others). M 0 R CM Dust Cover eu NoT Approximately z ® pN Ry 5' from Floor l�ae Screw (2) I I 16 oc N Front Edge of Rough -in o o M 00 Flush to 3/4" Below o C> WO Finished Wall Surface = o a ti ti � u) N z Alternate Extension Tube Position v O 0 i o 0CW o N W o 1 MED GAS WALL OUTLET DETAIL (PIPING ROUGH IN ONLY BY MECHANICAL) SCALE: NONE E E � U ._I U Q E LU Z m J e(i ��F OV W A, ti—o 477 �01 G/ST 0' Drawn By UMC Checked By RVK Legal: RECEIVED THIS DRAWING AND THE DESIGN Original Issue Date 1/21/2022 HEREIN ARE THE PROPERTY OF Jan 27 2022 UNIVERSITY MECHANICAL Job No. 8565 CONTRACTORS, INC. FOR THEIR CITY OF EDMONDS USE IN CONSTRUCTION OF THIS DEVELOPMENTScale NONE SERVICES PROJECT. NO OTHER USE SHALL DEPARTMENT BE PERMITTED WITHOUT THE Sheet No. WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. P6.01