APPROVED PLN BLD BLD2022-0107+Architectural_Plan+1.26.2022_6.58.25_PM+2644319
Insulation exposed during construction shall be replaced with highest extent feasible. R503.1.1. ALL WORK SUBJECT APPROVED TO FIELDINSPECTION FOR PLANS MUST BE O © O CODE COMPLIANCE ON JOB SITE BED RM BED RM ® TSD CLOSET SD NMD LIVING RM FURNACE RM CLOSET $SD BATH KITCHEN RA 0 R RANGE LAUNDRY SINK D717R FER ----------------------- Range to vent to the ; exterior with a min. 100CFM exhaust. ------------------------- ® Existing 2x4" Interior Wall with %2" drywall removed and replaced with new %2" drywall Existing 2x6" Exterior Wall with %2" drywall removed and replaced with new %2" Drywall; ExistingR-1-9 Insulation Batts to remain in place (f�SD Smoke Detector (Hard -Wired W/Battery Backup) CMD Carbon Monoxide Detector 0 Exhaust Fan — Direct Vent to Exterior Existing Window Schedule (no changes) 0 3"x 5' Single Hung Window O 6' x 6'10" Sliding Glass Door 0 4'x4' Sliding Window ® 6'x4' Sliding Window 0 5 -2'x5' Single Hung Window © 6- 5'x6'10" Sliding Glass Door 70 7- 2'x 5' Single Hung Window ® 8 — 6'x4'Sliding Glass Window 0 9- 5'x4' Sliding Glass Window City Of Edmonds Building Department Work BASEMENT REMODEL Address 20625 88TH AVE W Owner YOUNG Approved Date 02/14/2022 Building Official Erin Carter Permit Number BLD2022-0107 - WORK AREAS: KITCHEN & LAUNDRY Scope of Work • Add second Kitchen & Laundry to existing finished basement. • New Cabinets, plumbing fixtures & electrical as required. • Add New Microwave Hood fan exhaust above range, Laundry Exhaust Fan & Dryer Exhaust Fans vented directly to outside. • Add Carbon Monoxide Detector outside existing bedrooms. • No structural framing changes. Removing some drywall to access walls for new electrical & plumbing lines. Reinstall new %2" drywall where removed. Existing R-44 Insulation to remain. APPROVED BY PLANNING Feb 17 2022 YOUNG REMODEL 20625 88TH AVE W EDMONDS, WA 98020 RECEIVED Jan 27 2022 CITY Or EDMONDS DEVELOPMENT SERVICES 90 q)sD Smoke Detector (Hard -Wired W/Battery Backup) Existing Window Schedule 0 3"x 5' Single Hung Window 0 6' x 6'10" Sliding Glass Door 30 4'x4' Sliding Window ® 6'x4' Sliding Window 0 2'x5' Single Hung Window © 5'x6'10" Sliding Glass Door 0 2'x 5' Single Hung Window ® 6'x4' Sliding Glass Window 0 5'x4' Sliding Glass Window ORIGINAL BASEMENT FLOOR PLAN YOUNG REMODEL 20625 88TH AVE W EDMONDS, WA 98020 RECEIVED Jan 27 2022 DEVELOPMENT SERVICES DEPARTMENT