FIR2021-0121+Fire_Sprinkler_Plan+11.3.2021_3.21.14_PM+2500662CUP,PFNT 5TATIC WAV,
PI?F55UPF
5fAVE 70p5i
srn
E�I.FV- I0o'
MINIMUM 4"
WATF P, MAIN
3
n00
(31
I" MFTFp
20' OF
I I CQPPFp 5P51 055 FLOWING 2661 M
FXV,I01p, WALL
15' OF
1-1 / 211 POLY
WAT p 5 V I C F P TA L
W5
CONa&A [? APAMP, FITTING MOUNTING PML
N T5.
P
PI?OPFX FP TFF
9
MINIMUM CUT LFN6TH
OF TUNNG; 3-I/ 211
MAXIMUM CUT LFNC0
OF TU l%: 1211
Ir
PI?OPFX F11?F
5PINKLFI? VAPTFI?
FIFLb VFPIFY FIN15HFP
CFILING MAT DIAL
TO P7 TFpMINF MOUNTING
H%K bIMFN510N
NFPA IfV TVLF 5 6 b15TANCF5 MOM HFAT 50UPCF5
01?12INA2Y
INVMFbIATF
HFAT 50UPCF
TFMF,
TFMP,
135 � -170,
115' -225'
5112F OF �IpFl
36"
1211
`P,ONT OF FI MACF
6011
361'
WOOF PUpNil 5TM
4211
211
KITCHFN t A%G
1611
91'
WALK OVEN
1811
911
NOT AIP, FLUF5
1611
9"
UNIN51AT�l NEAT PUCT5
1611
911
UNIN51,1I,AT�P NOT WAV PH5
1211
611
5112F OF HOT AIP PIFF P,
2411
1211
FP,ONT OF NOT AR 171FFU5�r,
361'
I811
NOT WAV, H�AV
611
311
FUPNACF
611
311
50W-250W 1,I61-IT FIXTUpl
611
511
250*499W I ICK FIXTUP,�
1211
611
5J
V V�
N0�
/ 211 AQUAFFX FPOM 5 TO
MAN 5PP NUP COOP
ELFV-109'
`,I -1 / 211 AQUAPFX
TO 5Y5TFM
MINIMUM 3/ 411 5Y5TFM
PPAIN
TO PLUMING FIXTUI?F5 NOT
SHOWN ON 519I?INKLFI? LOOP
L
FULL P01?T
0—
DALL VALVF
F�Lv=io+
PFLIA3LF Model LL-FFC49 Concealed pendent Sprinkler
OO - - - 28 1/ 1611 Orifice, Maximum 5pacinq 16'xl6'
Sprinkler head demand; I� qpm @ 7.04
PFLIA3LF Model LL-PFC49 Concealed Fendent Sprinkler
O9, 155��, 7/ 1611 Orifice, Maximum 5pacinq 18'x181
Sprinkler head demand; 17 qpm @ 12,03
OU
1
m
266° PIG
21,11, PIG
O
— DINING
fl � OIO�D�]
X -f `I8°8° S.G.D.
w/ S.G.
.I
711 O'
" 50FF1 DN.
B
GEIL G 6"
AR ND
36" GOO <; I ISL ND, 5'x0l'
TOP
r
I HOOD VEN 2x KIN
1 V.T.O. NA W
1
HARDWO D I du L ND @ 5emlli
A.F
all
J �Z 1 'I V 21-011
T 42" REFER.
2w PIG
$ 2616 PIG
w/ 5.6.
Approved by Fire
14 A Floor
18 2nd Floor
32 TOTAI,
Approved set of plans must be on site at the time of
inspection. Failure to provide the approved set may
result in a re -inspection fee. System drain(s) required
at riser and must drain to the exterior. If riser is
above lowest grade, 2nd drain required and signage
at riser indicating location. Systems require signage
IAW NFPA 13D. Coverage required to the following
areas:
Clothes closets, linen closets and pantries exceeding
24 square feet in area, with the smallest dimension
greater the 3' and having wall and ceiling surfaces of
nsum board. Bathrooms more than 5F- ---._.o feet
11 1 u, — ... __ - -, - , dsent o, .
covered decks or porches, or living space above, a
least one quick -response intermediate temperature
sprinkler shall be installed above the equipment or
--a under living space.
Au ,.,1ior�rcc axrant attire if
living areas.
INAPI�V�L CONNFC10
INSTALL
'to q'overed pati
b O
2660 PIG 66 E
$ 2616 PIG I
ar
yIDE
GAS
MTTIPUPT05� rile 5RINUF 5Y5lM
• 5PPINKLFI: 5Y5TFM TO �F IN5TAlL1,F12 IN COMBINATION WITH THE
COLb 51VF OF THE POMF51C POTVIL WAV\ 5Y51FM,
• SPpINKLFI: 5Y5TFM PF516NFn TO THE 2016 F12IVON OF THE
NFPA 1317 5TANbAp12
• TH15 %661F5TF12 LAYOUT 15 I3A5FP UPON INF01?MATION
PPOVIPFn I3Y OTHFI?5 CHANGF5 IN CON5TI?UCTION OP FIFLb
CONnITION5 MAY OCCUR, WHICH MAY pFQUI I? CHAN6F5 TO THE
LAYOUT, IT 15 THE klF5FON51131LITY OF THE IN5TALLI tk TO NOTIFY
A-PFX I2F516N 51 fFVICF5 OF 5UCH CHAN6F5.
(EGRESS)
2x4 $ 2x6
WALL
�': RM 2
G
4°2 -
w/ LAM. GLA
NOTE: 5HOWER 4 —
AT INSTALLATION
MANUF. .I
_ - W�(iti�
O UF. SPECS.
f I R R4�4II l V.T.O.
HARD 00
LLPFC-16 f1� W LAUDII /� II II��aII
H.
2x6
ALL
-
IL
2x m
Ui
34Iy80
T
1
ILI
`
cr
G�
PAT�'1
246a
>a
;,�_�-SOFFIT
-
DN. O
H,22
HARDWOOD
TI E
TILE —
<;l
q�
tF_
'2
d
z
A
T11
�
2g68
IS" DE
5 SHELVES
`r
S.G.
j
BENG
36" GUARD
2x6 WALL
DN. =
ON CURB
—
o
2
5
4
5
6
a
0
TIGHT FITTING, 1-3/a" THI (MIN.)
o
FLR. ABV.
12
SOLID GORE WOOD D OR
A3
-----FURNAG OTE:
--
PLATE
O
UP 1-7 R.
RISE _ 7Y21
_ - - - - - GAS/P PANE OR OIL w/ - - -
- -
®I8
_
_ -- 26 GA. STRAP
TREADS = 10"
------ MIN. >� GGOf�
&OUTDOOR GOMBU5TION
'
�j,
AROUND W.H. T
WALL @ TOP $
2
�
BOTTOM
61 IS 14 3
12
11
AIR EXHAUST
1-r -T
A
WATER HEATER:
(i
NAVIEN NFE-240
4 dia.
1 1
I
TANKLE5 HEATER;
BOLLARD
PLRABV
I I'I
95; W/ OUTDOOR
. .
COMBUSTION
2x6 WALL
AIR � EXHAUST
O
I H.
I "x24"
OPEN TO AESV. 1
G.
2�MIN.
GRA SPACE
2—GAR &ARAGF
FOYER m
1
5, INSULATE
4" CONCRETEI+
I
HARDWOOD
II
4 WEATHERSTRIP
_
-
OARAGE NOTE:
p
I
308° S.C.
0
Jil
IN57ALL Y2" G.W.B. ®
LINE OF
I
w/ 3°26
K
WALLS $ POSTS.
WALL ABV.
S.G.
PIG ABV.
S.G.
�
CEILING
s/e," TYPE 'X' G.W.S. @
I
�v
1'-1 A.M.F.
2
I
CEILINGS 4 BEAMS.
'
I
1
DEN I4
— '
S Y2" �p
j
16080 O.H. I
`fly
m
CARPET A3
GARAGE DOOR i
m
I
166° PIC 1616 PIG
TYt' SILL
w/ 112, PIG ABV
i MAIN F L 00 P\"
1- / 114
11�11-011
i
(3)2616 PIG ABV.
o 30"x60" -
5OAKI NG
TUB
COLOV �INFTWL�6FNP
FLUF LINF5- FFFP TO FIXTUI?F5 (PATH, 5HOMP, FTC.)
FLACK LINF5- 5PI?INKLFIP, HEAR TO 5PQNKLFI? HFAI7,
i - 1 / 211 PH 5IZF
111 PIPF 51ZF
1-1/ 211 PIPE 51ZF
M05T HYPPAULICAILLY I?FMOTF HFAP5
HFAP # GPM PP? 55Ui E PEQ' b AT 5TVFFT
2 HFAn H3 & H 2 26 33,65
0
(EGRE55)
cul�
- 5.
`t L-----------------J �t 16 CARPET OC
e R.45.
4'-0" 2-0" 4'-O'-H1 4'-0" 2'-011 \41 Oil
HALL 40-70` _
CARPET G. 459
4,50
1
WHOLE HOUSE FAN -
m
2466
2'_
T'�9
(2)2x4
WALLS (EGRESS)
Pi/ AUTO TIMER $
ANUAL RRIi71E
H,.Z
0
RM 4
_
%zrFTC
VINYL
1-16
n�M
G
30"x60
s aJ
R. S.
TUBlSFfOWER
2668
TYP 5
j
40-��
WIG
LINEN
266e
G.O. O
Q
266e
CARPET
e�
TREAD5 = In't
ARD
LA \
=
FURNACE 8
12 IT 16 15 14 I
\
W.H. FLUE
2868
'
3
12'-O"
4'-O"
4'-O"77
4'-O" 4'-2" 3'-1011
BEAM AIBV
DN. I'! R.
01
BO
CASMT
o
1174
SOFFIT DN.
T,.T
56" GUARD —
H1�0
FLASHING TO WT. OF
I S O BEAM
i �2)5°16 PIG
1646 ' 1645
PIG PIG
2
F100
�Ikq'Il
UFFFr\" FLOOP\"
1411�11-011
�016 -I- . . n%dl
RVIGN SE
AES
11112 47TH AVF W
MUKILTFO, WA 98275
PH: 425-493-9680
FAX: 425-493-911 7
FMAIL; 5ale5@a-pexde5icin5ervice5.com
pF5I12FNTIAIL FIpF PI?OTFCTION 5Y5TFM
TURF TYPF; 1 / 211 TO 1-1 / 211 AQUAPFX
5PPINKLFk INFOkMATION
# 0r HF/Ab5 TH15 5HFFT - �2
# OF HF/Ab5 TH15 PROJECT - �2
5TAVC PPF55UI?F 15- 70
rr■■�■arr■■■■r.r■■■rrr■■■rr■s•
wASNINOTON sTAT/
OSRTIrIOATs OF 000MTKNOV
/1IIR ruava TION il"Umum sysTme
!� Kyle Robertson
i 7053-0809-A Leven
ie Lakeside Plumbing & Heating, s
LAKESPH0010A is
WI=a
RECEIVED
Nov 03 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
FI R2021-0121
V
N
z
0
v
z
O
0
I
PPFLIM, & CON5T, II-01-2021
2
3
N0,
PFV150N/ 155UF
bATF
FFOJFCf #
211101-16
COMPANY;
L4F9Pb PLUMNK6
CONTACT;
LAPpY f OlV5TON
CONTACT PHONF #
(206) �6�-g513
SCALP;
I/411 _ 11-011
17F5I61NFp7 Y;
LV1 y �VA
CHFCKFn 13Y;
NOAH F/AKMAN