Loading...
FIR2021-0109+Fire_Alarm_Equipment_Specification_Sheets+9.23.2021_2.48.10_PM+242591421462-City of Edmonds Fire Station 20 - FA Spec # Section Manufacturer Doc Name Doc # Silent Knight Silent Knight AES Gamewell-FCI Gamewell-FCI System Sensor System Sensor Silent Knight Silent Knight Mircom System Sensor Silent Knight Silent Knight Windy City Wire Windy City Wire Fire AlarmSystemEquipnent 6808 5860R 7707P-88-ULP GW-FAD SCRL SRL, P2RL P2RK SK-PHOTO-W SK-HEAT-ROR-W, SK-HEAT-HT-W CR-135MP C01224TR SK-PULL-DA SK-MINIMON 761360-S 767969-S F I R2021-0109 RECEIVED Sep 23 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Honeywell SELENT' KNIGHT Addressable Fire Alarm Control Panel The 6808 is an addressable fire alarm control panel (FACP) that can be configured to achieve an overall point capacity of up to 198 points. It has one built-in signaling line circuit (SLC), which can support 99 System Sensor® (SK) sensors and 99 SK modules or 127 Wochiki® (SID) devices per loop. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single -point communications. It also has a built-in, dual - line POTS and IP communicator and optional cellular side -cars. 6808 The 6808 system can be enhanced by adding modules such as the 1 1 6860 remote annunciator which also has four programmable function It supports a variety of devices, including the buttons to help automate tasks and reduce time spent atthe panel. 6860, 5860, and 6855 remote annunciators, SWIFT® wireless compatibility provides options for wireless detection through a Class A mesh network. It is ideal for hard -to -wire locations, buildings where new wiring is not allowed, orto provide an easy install fire system for new construction projects. SWIFT devices can be combined with other hard -wired 6808 compatible devices. The 6808 also has Form C trouble relay, and two programmable Form C relays, along with powerful features such as drift compensation, pre - trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and calibration trouble alert. FEATURES & BENEFITS • Capable of providing up to 198 points to satisfy smaller installation needs • Connect up to 17 panels on one site with convenient single - point access using the SK-N IC Network Interface Card. Connected panels can have mixed compatible FACP models. • Convenient field-upgradeabte firmware • integrated dual path iP and POTS communications and optional cellular side -cars for reliable backup • 6860annunciator with a 4 x 40 large display, and 4 programmable function buttons. Free -up time spent at the panel. Program them for simple or complex tasks. • Built-in USB interface for convenient and quick programming 5824 serial parallel printer interface module (for printing system reports), the 5496 NAC expander, 5895XL power module, and SK or 5D devices. • Programmable date setting for automatic and convenient Daylight Saving Time changes • Built-in dual phone line and digital alarm communicator/ transmitter (DACT) for additional communication options • 125 software zones and 125 output groups for flexible design options 6808 Product Information SIGNAL LINE CIRCUIT(SLC) The 6808 SLC loop supports multiple device types, maintenance alerts, and a built-in sensor test to comply with NFPA 72 calibration testing requirements. INDICATOR LIGHTS • General Alarm (Red): Flashes if in alarm; solid when alarm is silenced • Supervisory (Yellow): Flashes if a supervisory condition exists; solid when supervisory is silenced • System Troubles (Yellow): Flashes if a trouble condition exists; solid when trouble is silenced • System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared • System Power(Green): Flashes for AC failure; solid when power systems are normal USERINTERFACE The 6808 built-in 4 x 20 annunciator with 80 character LCD display and large easy -to -use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1,000 events for viewing from the built- in or remote annunciator. System operations can be initiated with a mechanicalfirefighter's key or a valid 4- to 7-digit operator's code. non -coded) signaling services. • UL Listed • CSFM 7165-0559:0502 • FDNYCOA#6246 • FM approved • Seismic (CA) (pending) 6808 KEYPAD' ORDERING INFORMATION PROGRAMMING 6808: Addressable Fire Alarm The 6808 system offers several options Control Panel. (Red cabinet). to simplify and speed-up programming JumpStart° AutoProgramming minimizes programming required to start a new system. The built-in keypad, or the 6860, 5860 or 6855 remote annunciators giveyou on -site access to current system programming. You can also program the system using the Honeywell Fire Software Suite (HFSS), which is Windows° based. SOFTWARE TOOLS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows® software system configuration tool to create a detailed Bill of Material (BOM) and battery calculations. HFSS: Honeywell Fire Software Suite provides communication and panel programming, detector status, event history and additional data. Requires a Windows -based computer. ADDITIONAL INFORMATION Twisted -unshielded pair wire is recommended. The 6808 also has 13 preset notification cadence patterns (including ANSI 3.41). AGENCY LISTINGS AND APPROVALS NFPA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72: Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterf low, sprinkler supervisory (DACT COMPATIBLE ANNUNCIATORS 6860:4x4O LCD remote fire annunciator (4 lines and up to 160 characters) per system; four programmable buttons 5860. 4x20 LC D remote fire annunciator. 5860 is gray; 5860R is red 6855:4x20 LCD remote fire annunciator 5865-3 or 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). The 5865-4 has key switches for silence and reset, and a system trouble LLD. 5880: LLD / 10 module has 40 programmable LED outputs and eight supervised dry contact inputs which are usefulfor custom applications. You can use up to eight 5880 modules on one control panel for maximum flexibility. Its compact size allows mounting inside the annunciator, or in an accessory cabinet. 6808 COMPATIBLE DEVICES AND ACCESSORIES See the data sheets listed below for a complete listing of the SK, SD or SWIFT devices. 53623: SK Devices Data Sheet 53624: SD Devices Data Sheet 350614, 350616 &350618: SWIFT wireless devices For a complete and current listing of compatible devices and accessories go to www.sitentknight.com Important: You cannot mix SK and SD devices in the same fire alarm system. SK COMPATIBLE ADDRESSABLE DEVICES SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°Ffixed temperture SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T.- Reflected beam smoke detectorwith testfeature SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended airspeed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-ROR: Fixed rate of rise detector (135'F) SK-HEAT-HT: Fixed high temperature thermal detector (190°F) SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10 input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-T. Photoelectric smoke detector with thermal (135°F fixed temperture) SK-PHOTOR: Photoelectric detector with remote test capability SK-PULL-SA: Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2:Addressable Dual relay/ monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module B21OLP: 6" mounting base 6501:4" Flangeless mounting base B20OS: Intelligent sounder base B20OS-LF: Low -frequency intelligent sounderhase B224RB: Relay base B224BI: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES SD505-6AB: Addressable 6" base SD505-61B:Addressable 6" short circuit isolator base SD505-6RB:Addressable 6" relay base SD505-6SB:Addressable 6'sounderbase SD500-AIM.Addressable input module (switch input) SD500-ANM: Addressable notification module SD500-ARM: Addressable relay module S0505-11TS-K: Remote test switch and LED indicator forthe SD505-DUCTR SD505-DUCT: Addressable Duct Smoke Detector. S13505-DUCTR:Addressable Duct Detector housing with relay base. SD505-HEAT: Absolute temperature heat detector. Trip point range from 135°F-150°F(0°C-370C). SD500-LIM:Addressable Line isolator module SD500-MIM: Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA:Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module AUDIBLE/VISIBLE DEVICES These AV devices are all 2-wire. Color: "R" indicates red; "W" denotes white. For a complete listing of Silent Knight AV devices go to www.silentknight.com. CHSRL/CHSWL: Wall chime/strobe CHSCRL/CHSCWL: Ceiling chime/strobe CHRL/CHWL:Wall chime HRL/HWL: Wall horn P2RL/P2WL: Wall horn/strobe PC2RL/PC2WL: Ceiling horn/strobe SRL/SWL: Wall stroke SCRL/SCWL: Ceiling strobe SPSCRL/SPSCWL: Ceiling speaker/strobe SPSRL/SPSWL: Wall speaker/strobe SPRL/SPWL. Wall speaker SPCRL/SPCWL: Ceiling speaker SWIFT WIRELESS DEVICES SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. WSK-WGI: Wireless Gateway WSK-PHOTO: Wireless Photoelectric smoke detector WSK-PHOTO-T: Wireless Multi -criteria photoelectric smoke detector with thermal detection (135°Ffixed temperture) and B510W 4" base WSK-HEAT: Wireless Heat, (135°F fixed temperture) and B510W 4" base WSK-HEAT-ROR: Wireless heat, ROR (135°Ffixed temperture) and B510W 4" base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module W-USB: SWIFT Tools USB transceiver used for communication with SWIFT devices SBUS ACCESSORIES 5496: A 6 amp notification power expander with four power -limited notification appliance circuit outputs. 5883: Relay Interface. Provides 10 Form C relays. 5824; Serial/Parallel Printer Interface Module for printer connection. 5895XL: Power Supplywith six Flexput' circuits, and two Form C relays. Max.16 per system. 5815RMK: Remote mounting kit. Dimensions: 10 3/8"W x 10-3/16"H x 3"D COMMUNICATION OPTIONS CELL-CAB-SK: Cellular communicator, metal enclosure with lock/key* CELL -MOD: Cellular communicator, plastic enclosure* *Sole path, powered by panel. IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-I13-2: Remote reporting via the Internet. Requires a VisorAlarm" receiver at the central station MISC. ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link for the 6808. SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber -Optic Multi Mode, transmitter and receiver SK-FSL: Fiber -Optic Single Mode RBB: Remote battery box accessory cabinet for batteries that are too large to fit in the FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406mm W x 254mm H x 152mm D). SK-SCK: Seismic Compliance Kit used to securely fasten batteries to the fire panel. 6808 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS (NACs) For a complete listing of all Overall Dimensions:16.36"W x 26.37H x 3.91"D Four programmable circuits which can be compliance approvals and Shipping Weight: 32 lbs. programmed individually as: certifications, please visit www.silentknight.com. Color: Red NACs: 3A @27.4VDC per circuit, power -limited (with a maximum current of 6A) Microsoft, Windows, and ENVIRONMENTAL Auxiliary Power Circuits: 3A@ 27.4VDC per circuit, the Windows Logo are Operating Temperature: 32°Fto120°F (D°Cto power-lim egistered trademarksited ortrademarksof 49°C) Microsoft Corporation. Humidity: 0 to 9311/6 relative humidity (non- Supports Class B (Style 4) and Class A (Style 6 or 7) condensing) configuration for the SLC Silent Knight@, Honeywell"' and SW IFT' are registered trademarks of Honeywell ELECTRICAL E WIRING: See the product manual for wiring details International, Inc 6808 Primary AC:120 VAC @ 60Hz, 3.3A Total Accessory Load: 6A @ 27.4VDC power -limited This document is not Standby Current:l9DmA intended to be used for installation purposes. We Alarm Current:25OmA tryto keep ourproduct Battery Charging Capacity: 7 to 35AH information up -to Battery5ize: 7AH to 18AH max. allowed in control can otcand accurate. 6 cannotcoverallspecpic anel cabinet. Larger capacity batteries can be p 9 p y or applications or anticipate housed in RBB accessory cabinet. ail requirements. All specifications are subject to change without notice, For Tech nicalSupport, ca11800-446-6444. For more information Learn more about Honeywell Silent Knight and other products byvisiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 35i6081 A 111/17 Honeywell 800-328-0103 © 2017 Honeywell International Inc. SILENT 5860 Remote Annunciator KNIGHT by Honeywell Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility. Now you can operate and program your IntelliKnight system from up to eight locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy -to -use interface found on the IntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error -free system operation. All operations —including reset, silence, detector status checking, fire drill, and programming —are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description Features include an 80-character backlit LCD providing easy -to - understand system messages. The annunciator is ergonomically designed with over -sized buttons for the most frequently used features, like Reset and Silence. In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. The annunciator is available in gray to match virtually any decor and red for applications where the annunciator must stand out. The annunciator enclosure can be surface or flush mounted. A trim ring kit is available for surface mounting. Features • 80-character backlit LCD display (4 lines with 20 characters on each line) • Tactile and audible feedback • Accepts user codes or fire fighter's key • Larger keypad buttons for system reset and silence • Install up to eight 5860s per FACP • Available in red or light gray • Support for simultaneous use of multiple 5860s • RS-485 interface to panel • Operation and appearance is identical to 5860 built-in annunciator • On -board piezo sounder audibly indicates alarms, troubles, and supervisories • Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions • Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on SBUS) • UL listed, complies with NFPA 72 • CSFM approved Electrical Specifications Operating Voltage: 24 VDC Standby Current: 20 mA max Alarm Current: 25 mA Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) Max Per System: 8 Mechanical Specifications Physical 9.1" W x 7.4" H x 1.5" D (23.1 W x 18.8 H x 3.8 D cm) Shipping Weight: 2.8 Ibs (1.3 kg) Color 5860R: Red 5860: Gray 5860 Environmental Operating Temperature: 32°F — 120°F (0°C — 49°C) Humidity: 10% — 93% non - condensing Compatibility The 5860 is compatible with the following FACP's: • 5820XL Addressable Fire Control Panel • 5820XL-EVS FACP with Emergency Voice System • 5808 Addressable Fire Control Panel • 5700 Addressable Fire Control Panel Listings NFPA 72; UL Listed; CSFM 7170-0559: 135; MEA 429-92-E Vol. IX; FM Approved 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator. All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. %Vm Awn " 19 WO Fett iFrom #AC P W tc C4M $Ww, Pty UrOwm + afilla iatrte Ir1CCr;A11iR41 ,FAC-P Ordering Information 586OR Remote Annunicator four line LCD annunciator with 20 characters per line. Red. 5860 Remote Annunclator.Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring for surface mounting. 586OTG Gray Trim Ring for surface mounting. SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350224 Rev F subject to change without notice. For more information, contact Silent Knight © 2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com 319 Q s,u Q 7 RADIO ALARM TRANSMITTER (RAT) SUBSCRIBER UNIT 8 AES 7707P-88-ULP J4 REQUIRED DISTANCE FROM WALL TO T—bk ACCOMODATE FOR DOOR SWING � Mounts on top of 7788E Ro No > INTELLIPRO ACCESSORY Ro w J2 DIGITAL DIALER INTERFACEuUJ) O AES 7794A Oz0 � J3 JS TO FACP 060 IN OUT J6 J7 J8 J9 it w3tlF1L0 w3lC V O Ctr OV mny np np MW 1,V Rip ny1 Rena, O &m CAB 7794A 1001001001001O vn0 T+ o ASSEMBLE LY ffffm gum 7711 ® 000® � O NO NC C NO INC C E T G V+ + � O BATTERY 12VOLT 12 AMP. HR.7707P�88�ULP DETAIL VIEW / 7707P-88-ULP FRONT VIEW 7707P-88-ULP 3D VIEW Honeywell I Accessories QGamewell Fire Alarm Documents (FAD) Cabinet Fire Alarm Storage Cabinet General The Gamewell-FCI Fire Alarm Documents Cabinet (FAD) is the perfect solution to meet the demanding code standards required today. Gamewell-FCI's primary goal is to manufacture code compliant solutions and this product allows you to do just that. This cabinet is the answer to Comply with the NFPA 72 2007, Section 6.2.2.1 requirements which states, 'A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit. The Fire Alarm Documents cabinet maybe used as a storage box for both printed and digital documentation, enabling you to store the system's test and certified' inspectic n documents, service records, manuals and AS built drawings. This cabinet is constructed of durable 16 gauge steel with a solid piano hinge and key lock. The cabinet includes a 4GB USB memoryflash drive interface. Using a standard USB B connector, the USB flash drive interface allows you to use any standard USB printer cable to upload or download information. This feature allows you to store the fire alarm software in one secure place, so that the Technician can easily access the software and service the system. Fire Alarm Documents Cabinet The Fire Document Box (FDB) interior is designed to contain critical manuals and documents. It is constructed with a durable steel retainer. The FDB has two key ring hooks to hold system keys, and a frame to insert Authorized personnel business cards. In the inner door, you can add the Legend Sheet to record property, system, service, code and AHJ certification information, as well as required documentation. (See Figure 2). Ordering Information: GW-FAD: Fire Alarm Storage Cabinet, Red FEATURES & BENEFITS • Installed with a 4 gigabyte digital flash drive interface with USB B connector • Overall Dimensions 12"Width x 13" Height x 2 1/4" Depth (30.48 W x 33.02 H x 5.71 D cm) • Offers two, key ring hooks to hold the system keys • Contains a frame plate to insert Authorized Personnel business cards • Constructed with 16 gauge steel box and cover for added security with a solid stainless steel hinge • Coated with a durable, baked -on finish (other colors available) Built with a stainless steel piano hinge with standard 3/4"cat 30 key lock (other lock assemblies available) • Includes a Legend Sheet to record passwords and system information • Imprinted with white indelible ink, 1" high lettering labeled, "FIRE ALARM DOCUMENTS" Figure 1 shows the interior enclosure of the Fire Alarm Documents cabinet. USB Storage Interface requires Standard USl Connector Ring Hooks Card Holder Legend sheet used to store system information including the following: Contacts Sign -off Maintenance Test information -Alternate locations of additional records Figure 1 Fire Alarm Documents Cabinet Figure 2 shows the Legend Sheet attached to the inner door of the Fire Alarm Document Cabinet (See Figure 2). Property Information Minimum Required Documentation Name of Property: 1 Written narrative providing intent and system description. Address: F_1NiA FlEnclosed or Alt. Location: 2 Riser diagram Description of Property: DocupancyType: �N1A �EnclosedorAtt.Location: Certification and Approvals 3 Floor plan layout showing location of all devices and control equipment. 16.1 System Installation Contractor. F]N/A Enclosed or Alt. Location: This system, as specified herein, has been installed and 4 Sequence of operation in either an inpull output matrix or narrative form. tested according to all NFPA Standards cited therein. FIN1A Enclosed or Alt. Location: Signed: 5 Equipment technical data sheets. FINIA F1 Enclosed or Alt. Location: Printed Name: Date: 1 1 6 Manufacturers published instructions, including operation and maintenance instruction. Organization: FINIA Enclosed or Alt. Location: Title: 7 Battery calculations (where batteries are provided). DWA FlEnclosed or Alt. Location: 8 Voltage drop calculations for notification appliance circuits. Phone: 16.5 Authority Having Jurisdiction: I have witnessed a satisfactory acceptance test of thiswith FINIA F-1 Enclosed or Alt. Location: system and find it to be installed and operating property in 9 Completed record of inspection and testing in accordance with TU and 7.8.2. accordance with As approved plans and specifications, FIN1A Enclosed or Alt. Location: its approved sequence of operations, and with all NFPA 10 Completed record of completion in accordance with 7.5.6 and 7.8.2. standards cited herein. [_]N/A Enclosed or Alt. Location: Signed: 11 Copy of site speck software, where applicable. FINIA D Enclosed or Alt. Location: Printed Name: Date: 1 1 12 Record (as-buiif) drawings. Organization: F-]NiA DEnclosed or Alt. Location: Title: 13 Periodic inspection, testing, and maintenance documentation in accordance with Section 7.6. FINIA Enclosed orAtt. Location: Phone: Equipment Information ID No. 1: 14 Records, record retention, and record maintenance in accordance with 7.7. NIA D Enclosed or Alt. Location: Serial: Access Code: ID No. 2: Signed: Date: 1 1 Serial: Access Code: Figure 2 Legend Sheet Fire Alarm Documents (FAD) Cabinet Technical Specifications SYSTEMS FAD: Fire Alarm Documents Cabinet Dimensions: 12"Wx 13" H x 21/4" D (30.48 W x 33.02 H x 5.71 D cm) Door Keylock: Harrel lock and piano hinge Dimensions,. 3/4" barrel lock and 12' (30.48 cm) piano hinge FAD Cabinet: W Listed, constructed of 18 gauge cold rolled steel Cabinet Finish: Red powder coat epoxy finish Cabinet Cover Label: Silkscreen imprinted with white indelible ink, 1' high lettering labeled,'FIRFALARM DOCUMENTS' Cabinet Keylock: Keylocked with 3/4' barrel lock and 12' (30.48 cm) width stainless steel piano hinge Cabinet Backbox: The backbox includes a 4-hole knockout mounting pattern. Cabinet Frame Plate: insert frame plate accommodates and protects standard 8 1/2x 11 manuals and document records. Cabinet Inner Door Label: Legend Sheet attached to the inner door frame for system required documentation, key contacts and code information. Cabinet Flash Drive Interface:4 Gigabyte (minimum) digital flash memory drive with a standard USB B connector (used to upload and download information) is securely assembled to the interior cabinet. The drive is restricted to Authorized personnelwith permission to use secure hardware devices to access the records. Cabinet Key Holder: Two key ring holders and a pre - assembled frame plate to insert Authorized Personnel business cards. For more information Learn more about Gamewell-FCI's Fire Alarm Documents (FAD) Cabinet and other products available by visiting www.Gamewelt- FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com STANDARDS The Fire Alarm Documents (FAD) Cabinet is designed to comply with the following standard: UL Standard: S2580 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. U L: S2580, Vol. 3 CSFM:7300-0553-0110 N FPA: 72 2007 NEMA ISO 9001 Certification 9021-61027 1 A 105/18 92018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www-gameweli- fci.com/en-US/ documentation/Pages/ Listings.aspx Gamewell-FCI® is a registered trademark of Honeywell I nternational Inc. Space Age Electronics, Inc. is a ©copyright. UL® is a registered trademark of Underwriter's Laboratories Ino. This document is not intended to he used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot coverall specific applications or anticipate all requirements. Allspecifications are subjectto change without notice. Honeywell Honeywell I Notification Appliances QGamewell � � L-Series, Indoor Strobes and Horn Strobes Indoor Selectable -Output Strobes/Horn Strobes for Ceiling Applications General The L-Series audiblevisible notification products offer the most versatile and easy -to - use product line of horns, strobes, and horn strobes in the industry. This product includes lowercurrentdraws and modern aesthetic design which reduce installation times and maximize profits. In addition, the L-Series offers white and red plastic housings and wall and ceiling mounting options. Simi [arto the entire L-Series product line, the ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying the installation_ All devices offer a plug-in design so that there is mini mat intrusion into the backbox. These features make installations fast and foolproof while eliminating costly and time-consuming ground faults. To simplifythe installation,the L-Series uses a universal mounting plate allowingyou to mount the devices to a wide array of backboxes. With an on -board shorting spring, Installers can testwiring continuity before the device is installed. Installers can also easily adapt devices to suit a wide range of application requirements using the following: • Field -selectable candela settings • Automatic selection of 12- or 24-volt operation • Rotary switch for horn tones with two volume selections FEATURES & BENEFITS • Listed for ceiling mounting only • Features a plug-in design so that there is minimal intrusion into the backbox • Designed with a tamper -resistant construction • Provides an automatic selection of 12- or 24- volt operation at 15 and 30 candela • Uses field-selectabte candela settings on the following ceiling units: - 15 - 30 - 75 - 95 - 115 - 150 - 177 • Produces horn rated at 88+ d BA at 16 volts • Offers a rotary switch for horn tone and two volume selections • Includes a universal mounting plate for ceiling units Ceiling Horn Strobe • Contains a mounting plate with a shorting spring feature that checks the wiring continuity before device installation • Compatiblewith MDL3 sync module • Supports electrical compatibility with the Legacy SpectrAtert and the SpectrAlert Advance devices Architect/Engineer Specifications General The L-Series ceiling -mount strobes and horn strobes shall mount to any of the following: • double -gang backbox • 4-inch octagon backbox • a standard 4 x 4 x 1 1/2-inch backbox Two -wire products shallalso mounttoa single -gang compact2 x4 x 17/8-inch backbox.A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuitwiring shall terminate atthe universal mounting plate_ Also, the L-Series products, when used with the Sync -Circuit Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24volts. When it is used with the Sync -Circuit Module, the following occur: • 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts. • 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. The Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC orfull-wave rectified unfiltered powersupply. Ceiling strobes and horn strobes shall have the following field - selectable candela settings including: • 15 • 30 • 75 95 • 115 • 150 • 177 Strobe The strobe shall be an L-Series Model listed to UL Standard 1971 and shall be approved forfire protective service. The strobe shall be wired as a primary -signaling notification appliance and complywith the Americans with Disabilities Act requirementsforvisible signaling appliances, flashing at 1 Hz overthe strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/ reflector system. Horn Strobe Combination The horn strobe shall be an L-Series Model listed to UL Standard 1971 and ULStandard464and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and complywith the Americans with Disabilities Act requirements forvisible signaling appliances, flashing at 1 Hz overthe strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporalthree pattern and a non -temporal (continuous) pattern. These options are set by multiple position switch. The horn on horn strobe models shall operate o a coded or non -coded power supply. Synchronization Module The module shall be a Sync -Circuit model MDL3 listed to UL Standard 464 and shall be approved forfire protective service. The module shall synchronize the L-Series strobes at 1 Hz and synchronize horns attemporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single -pair of wires. The module shall mount to a 411/6 x 411/16 x 2 1/8-inch backbox. The module shall also control two Style Y (Class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy -chaining two or more synchronization modules togetherwill synchronize allthe zones they control. The module shall not operate on a coded power supply. UL Current Draw Table 1 lists the UL maximum strobe current draw. Candela 8-17.5 Volts 16-33 Volts FWR DC DC 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 Table 1: UL Maximum Strobe Current Draw (mA RMS) UL Current Draw Data Table 2 lists the maximum UL Current Draw (mA RMS) allowed far 2-Wire Horn Strobes. DC Input 8-17.5 Volts 16-33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non -Temporal High 106 173 71 90 141 165 187 230 273 Non -Temporal Low 95 166 54 71 124 161 170 216 258 3.11K Temp Hi 111 164 69 94 147 163 184 229 257 3.11K Temp Low 103 163 54 88 143 155 185 212 252 3.11K Non -Temporal High 111 172 69 94 144 164 202 229 271 3.11K Non -Temporal 103 1169 154 188 1131 1155 1187 1217 1259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non -Temporal High 107 135 179 198 223 254 286 Non -Temporal Low 78 101 151 172 199 229 262 3.1KTemporal High 108 135 179 200 225 256 289 3.11K Temporal Low 79 101 150 171 196 229 260 3.11K Non -Temporal High 108 1135 1179 1200 1225 1255 1289 3.11K Non -Temporal Low 179 1101 1150 1171 1196 1229 1260 Table 2 UL Max. Current Draw(mA RMS), 2-Wire Horn Strobe Horn Strobe Tones and Sound Output Data Table 3 lists the horn strobe tones and sound output date. Switch Position Sound Pattern dB 8-17.5 Volts 16-33 Volts FWR DC DC 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHzTemporal High 83 88 88 6 3.1 KHzTemporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 Table 3: Horn Strobe Tones and Sound Output Data L-Series Dimensions Figure 1 illustrates the dimensions for the ceiling -mount horn strobes. 6.83" diameter (173 mr^r 2AT'(62.7 mm) 1.37" (34.8 mr11) Figure 1 Ceiling -Mount Horn Strobes L-Series Dimensions Figure 2 illustrates the dimensions for the ceiling backbox surface mount backbox. 8.82" diameter (175. 2.56" Figure 2 Ceiling -Surface -Mount Sackbox L-Series Ordering Information Ceiling Horn Strobes: PC2RL: 2-Wire, Horn Strobe, Red PC2WL: 2-Wire, Horn Strobe, White PC4RL:4-Wire Ceiling Horn Strobe, Red, FIRE PC4WL:4Wire Ceiling Horn Strobe, White, FIRE Ceiling Strobes: SCRL: Strobe, SCWL: Strobe, White SCWL-CLR-ALERT: Strobe, White, ALERT 4 L- Series Dimensions Figure 3 illustrates the dimensions forthe ceiling backbox surface mount backbox. Figure 3 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Backbox SL Series Dimensions Figure 4 illustrates the dimensions for the ceiling backbox surface mount backbox. Figure 4 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Backbox L-Series Ordering Information Accessories: TRC-2: Universal Ceiling Trim Ring Red TRC-2W: Universal Ceiling Trim Ring White SBBCRL: Ceiling Surface Mount Back Box, Red SBBCWL: Ceiling Surface Mount Back Box, White L-Series, Indoor Strobes and Horn Strobes Technical Specifications SYSTEMS Temperature Ranges: Standard Operating Temperature: 321Fto 120°F(0°C to 49°C) Humidity Range: 10to 93%non-condensing Voltages: Strobe Flash Rate:1 flash per second Nominal Voltage: Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2: 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3): 8.5 to 17.5V(12 V nominal) or 16.5 to 33 V(24V nominal) Wire Gage: Input Terminal Wire Gauge: 12 to 18 AWG Dimensions: Ceiling -Mount Dimensions (including lens): 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling -Mount Surface Mount Back Box Skirt Dimensions (SBBCR, SBBCW): 6.9' diameterx 3.4' high (175 mm diameter x86 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time --varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 491C/32 -120°F and at a relative humidity 93%+ 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F For more information Learn more about Gamewell-PCPs L-Series, Indoor Strobes and Horn Strobes and other products available by visiting www.GameweLFCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.hnneywetl.com STANDARDS The L-Series, Ceiling Strobes and Horn Strobes are designed to comply with the following standard: UL Standard: UL 1971 and UL 464 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factoryfor latest listing status. UL: S5512, S4011 CSFM: 7135-1653:0503 7125-1653:0504 ISO 9001 Certification 9021-60928 1 C 1 03/18 02018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit httpJ/www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series® and Gameweli-FCI® are registered trademarks of Haneywell International Inc. UL® is a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. Allspecificatims aresubjectto change without notice. Honeywell SrsrEM SENSOR' Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Updated Modem Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 F I R E • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Strobes and Horn Strobes listed for wall mounting only • Horns listed for wall or ceiling use Agency Listings SIGNALING LISTED nYPFOVEQ S5512 FM approved except 7125-1653A5rW S4011 far ALEPT models 7135-1653'M 3057383,3057072 The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AWSB65-M • 2122/201 B - Page 1 L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 N-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double -gang back box. L-Series compact products shall mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync -Circuit`" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, 12-volt-rated notification appliance circuit Outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lenslreflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync -Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 41y16 x 411/15 x 211a-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32�Fto 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range' 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 "Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) In put Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7"W x 1.91-D (143 mm L x 119 mm W x 49 mm D) Compact Wall -Mount Dimensions (including lens) 5.26" L x 3.46" W x 1.91" D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.25'D (143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" L x 3.45" W x 1.25" D (133 mm L x 88 mm W x 32 mm D) 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVD5865-05 • 212912018 • Page 2 UL Current Draw Data UL Max. Strobe Current Draw (rnA RMS) 8-175Volts 16-33 Volts Candela DC DC FWR 8-175 Volts 16-33 Volts Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal Range 30 143 63 83 75 NIA 107 136 95 NIA 121 155 110 NIA 148 179 135 NIA 172 209 185 NIA 222 257 High 39 44 54 Temporal Low 28 32 54 Non -Temporal High 43 47 54 Non -Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 8—i7.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non Temporal High 106 166 73 94 139 160 182 211 262 Non Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.1 K Non -Temporal High 99 162 69 90 135 157 175 208 261 3.1KNon-TemporalLow 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non -Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3-1KNon-Temporal High 104 131 177 204 230 264 326 3.1 K Non -Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data ■:.rTrrr..:orn 5 robe aitprrtiroA 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3A KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 9` Coded High 85 90 90 1W 3.1 KHz Coded High 84 89 89 ' Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must be provided by the NAC. If the NAC voltage is held constant, the horn output remains constantly on. AWS865-05 • 2122M18 • Page 3 L-Series Dimensions 1.91" 3.46' 49.5 mm 1.25" 3.57' Im. 80 mm 25" � 32.. (9.1 on) (3.9 cm) 32 mm 0 W o �� p p0 00 0 5.2T ,. a, p�d0u0ppp0p0 5.38' 1339mm '-'-"-1 5.27' Op�0/ Op40p' (13.7 an) O 133.9 mm p00100pOt13o 000t000pt0t0 O 0 A0549-M Aa547-00 A0557-60 Compact Strobe, Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL, SBBGWL 4.70" (11.94 cm) 1.91" 4.7, (d.85 cm) 119 mm 32 mm asz� 11229 cm( (499 an) (3.18 mm) 014 In _4L W Zcm)LJ 5.67"G(144 mm tp000p000p0 A0554-01 Strobe, Horn Strobe Horn nosaaw Wall Surface Mount Back Box SBBRL/SBBWL L-Series Ordering Information Wall Horn Strobes Horns* P2RL 2-Wire, Horn Strobe, Red HRL* Horn, Red P2WL 2-Wire, Horn Strobe, White HWL* Horn, White P2GRL 2-Wire, Compact Horn Strobe, Red HGRL* Compact Horn, Red P26WL 2-Wire, Comp 2 tils act Horn Strobe, White HGWL* Compact Horn, White P2RL-P 2-Wire, Horn Strobe, Red, Plain Accessories P2WL-P 2-Wire, Horn Strobe, White, Plain TR-2 Universal Wall Trim Ring Red P2RLSP 2-Wire, Horn Strobe, Red, FUEGO TR-2W Universal Wall Trim Ring White P2WLSP 2-Wire, Horn Strobe, White, FUEGO SBBRL Wall Surface Mount Back Box, Red P4RL 4-Wire, Horn Strobe, Red SBBWL Wall Surface Mount Back Box, White P4WL 4-Wire, Horn Strobe, White SBBGRL Compact Wall Surface Mount Back Box, Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box, White SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Notes: All -P models have a plain housing (no "FIRE" marking on cover). All -SP models have "FUEGO" marking on cover. All -ALERT models have "ALERT' marking on cover. *Horn -only models are listed for wall or ceiling use. SYSTEM3825 Ohio Avenue • St. Charles, IL 60174 0201a systemsensor Phone: BOO-SENSOR2 • Fax: 630-377-6495 PfOdu tspec"ica"ons becttocharge wid�tn°" Visit"nms—mm SENSOR fa casein product in4ormatwn, including the latest versos of this data sheer www.systemsensor.com Avos865-05 - V22f2018 ii SrsrEM SENSOR' Outdoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications Speci Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field -selectable candela settings: 15, 15175, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from -40°F to 151aF • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Listed for ceiling or wall mounting Agency Listings SIGNALIN & F M G r r. MEA730a 1653187 (ouldocr strobes) tISTEd 7125-1653188 (ham strobes, S4011 (chimes, ban strobes. horns) APPROVED approved chime strokes) S3593 {outdoor and alert strohes) 3023572 M&4452-0.5-E 7135-1653189 (hams, chimes) SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from --40oF to 151 °F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wali applications include a variety of features that increase application flexibility and simplify installation. First, field -selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in -and - out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock -outs located on the back eliminate the need to drill holes for screw -in mounting. Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch knock -outs at the back. A screw -in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit'" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync*•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for tire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options shall be set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non -coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL The horn strobe shall be suitable for use in wet environments. Operating Temperature -40°F to 151 °F (-40°C to fib°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DCIFWRI Operating Voltage Rangez 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6"L x 4.7"W x 2.5"D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3" D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7"L x 5.1 "W x 2.0" D (145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. R S, PC, and SC products will operate at 12 V nominal only for 15 and 15175 cd. AVDS01201 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) E3��� 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB 8-17.5 Volts 16-33 Volts DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15175 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Law 38 44 44 48 75 NA NA 158 153 Non -Temporal High 57 56 69 75 95 NA NA 181 176 Non -Temporal Medium 42 50 60 69 110 NA NA 202 195 Non -Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15l75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non -Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 85 95 110 166 189 208 216 Non -Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire 16-33 Volts Horn Strobe, High Candela Range (135-185 cd) 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn and Horn Strobe Output ,8-175 candela ratings must be reduced in accordance with 16--33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output (cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at-40°F 15 Do not use below 32°F 15175 30 75 44 95 70 110 110 115 115 135 135 150 150 177 1177 185 1185 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- High 82 82 88 88 93 92 100 100 Temporal 5 Non- Medium 78 78 85 85 90 90 98 98 Temporal 6 Non- Low 75 75 81 81 88 84 96 92 Temporal 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. Aws0121)1 SpectrAlert Advance Diagrams Wall -Mount Horn Strobes C� erproof Back Box Wall -Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information 11110011311 Horn Strobes —it-escription P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor includes plastic weatherproof back box P2RHK*t 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: ' Add 'i to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-R t Add "-R" to model number for weatherproof replacement device (no back box included), onlyfor use with weatherproof outdoor flush mounting plate, WTP and WTPW "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150. 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. SYSTEM ®hochwga5 3825 Ohio Avenue + St. Charles, [L 60174 P�m��s��f,"ati��,e�t�o"h�,9ew,t"wim Ysits�tems­mm SENSOR Phone: BOO-SENSOR2 + Fax: 630-377-6495 a"e"�°°° `t"� "a°° nvoSSoi zai 01201 3�e� «s° °'u s data �` •liz SKmPHOTOmW SERIES Addressable Photoelectric Smoke Detectors The Silent Knight"' SK-PHOTO-W Series feature a modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The SK-PHOTO-W Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the SK-PHOTO Series detectors. Anew modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to senses make produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be setwith rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detector for use with DN R Series duct detector housings. FEATURES AND BENEFITS • Designed to meet UL 1268 7th Edition • Sleek and stylish contemporary design • Stable communication technique with noise immunity • Addressable by device • Rotary, decimal addressing (Refer to the Silent Knight panel manuals for device capacity) • Two -wire SLC connection • LEDs blink every time the unit is polled • 360°-field viewing angle of the visual alarm indicators (two bi-color LEDs); LEDs blink green in Normal condition and turn on steady red in Alarm • Integral communications and built-in device -type identification • Remote test feature from the panel • Built-in functionaltest switch activated by external magnet • Walktestwithaddress display (an address of 121 will blink the detector LED 12- (pause)-1) • Low standby current • Built-in tamper -resistant feature • Designed for direct -surface or electrical - box mounting • Sealed againstback pressure • Plugs into separate base for ease of installation and maintenance • Expanded color options • SEMS screws farwiring of the separate base • Optional remote, single -gang LED accessory • Optional sounder, relay, and isolator bases Honeywell SILENT' KnTIGHT INSTALLATION The SK-PHOTO-W Series plug-in intelligentthermaIdetectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see SK-61045. Note: Because of the inherent supervision provided bythe SLC loop, end -of -line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. Note: When using relay or sounder bases, consult the SK-ISO installation sheet 156-3627 for device limitations between isolator modules and isolator bases. OPERATION Each SK-PHOTO-W Series detector uses one of the panel's addresses (total limit is panel dependent) on the Signaling Line Circuit (SLC). It responds to regular polls from the control paneland reports its type and the status. If it receives a test command from the panel (or a local magnettest), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The SK-PHOTO-W Series offers features and performance that represent the latest in smoke detector technology. PRODUCT LINE INFORMATION Note: "-IV" suffix indicates ivory color. SK-PHOTO-W: White, low -profile photoelectric sensor SK-PHOTO-T-W: White, same as SK-PHOTO-W but includes a built-in 135°F (57°C) fixed -temperature thermal device S K-PHOTO-R-W: White, low -profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW B300-6: White, standard flanged low -profile mounting base B300-6-BP: Bulk pack of B300-6, package contains 10 B300-6-IV: Ivory, standard flanged low -profile mounting base B501-WHITE: White, standard European flangeless mounting base B501-BL: Black, standard European flangeless mounting base B501-IV: Ivory, standard European flangeless mounting base B501-WHITE-BP: Bulk pack of B501-WHITE, contains 10 B20OS-WH: White, Intelligent, programmable sounder base B20OS-IV: Ivory, Intelligent, programmable sounder base B200SR-WH: White, Intelligent sounder base for retrofit applications B200SR-IV: Ivory, Intelligent sounder base for retrofit applications B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounderbase B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounderbase 8200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications B224RB-WH: White, plug-in System Sensor® relay base B224RB-IV: Ivory, plug-in System Sensor relay base B224B1-WH: White, plug-in System Sensor isolator detector base B224BI-IV: Ivory, plug-in System Sensor isolator detector base ACCESSORIES TR300: White, replacement flange for B21OLP or B300-6 bases TR300-IV: Ivory, replacement flange for B21OLP or B300-6 bases RA100Z(A): Remote 3 - 32 VDC LED annunciator, mounts to a U.S. single -gang electrical box, for use with B501 and B300-6 bases only M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: White, detector color kit, pack of 10 CK300-IV: Ivory, detector color kit, pack of 10 CK300-BL: Black, detector color kit, pack of 10 Page 2 of 3 — 351634:B • 7/1/2019 SK-PHOTO-W SERIES TECHNICAL SPECIFICATIONS PHYSICAUENVIRONMENTAL Sensitivity: - UL Applications: 0.51)/o to 4.00/a per foot obscuration. - ULC Applications: 0.50/c to 3.511/6 per foot obscuration Size: 2.0" (5.3 cm) high; base determines diameter - B300-6: 6.1" (15.6 cm) diameter - B501: 4" (10.2 cm) diameter For a complete list of detector bases, see S K-61045. Shipping weight: 3.4 az. (95 g) Operating temperature range: • SK-PHOTO-W:32°Fto 122°F(0°Cto 50°C) • SK-PH0T0-T-W:32°Fto100°F(0°Ctc 38°C) • SK-PHOTO-R-W installed in a DNR/DNRW: -4°F to 158°F (-20°C to 70°C) UL/ULC Listed Velocity Range: 0-4000 ft/ min. (1219.2 m/mfn.), suitable for installation in ducts Relative humidity: 101)/o — 93% non - condensing Thermal ratings: fixed -temperature set point 135°F (57C), rate -of -rise detection 15°F (8.3"M per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak Standby current (max. avg.): 200pA @ 24 VDC (one communication every 5 seconds with LED enabled) Max current: 4.5 mA C& 24 VDC ("ON") Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.silentknight.com DETECTOR SPACING AND APPLICATIONS Silent Knight recommends spacing detectors in compliance with NFPA 72. In law airflow applications with smooth ceiling, space detectors 30 feet (9.1m). For specific information regarding detector spacing, placement, and special applications referto NFPA 72. A System Smoke Detector Application Guide, documentA05-1003, is available at www.systemsensor.com. AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document.In some cases, certain modules or applications may not be listed bycertain approval agencies, or listing may be in process. Consult factory for latest fisting status. • UL Listed: S6173 • FM Approved • CSFM:7272-0559.0512 351634 I B 1 01/19 02019 Honeywell ht.—tio dH. Honeywell SILENT' KNIGHT SKmHEATmW SERIES Addressable Heat Detectors The Silent Knight"' SK-HEAT-W Series heat detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and advanced thermal technologies make the SK-HEAT-W Series ideal for both system operation and building design. The series includes a 135°F/57°Cfixed-temperature, rate -of -rise, and a 180°F/88°Cfixed high -temperature detectors and are direct replacements for the SK-HFATSeries heat detectors. The point ID address, set using rotary decimal switches, provide specific detector locations. These thermal detectors provide effective, intelligent property protection in a variety of applications. • SK-HEAT-Woffers 135°Ffixed thermal detection. • SK-HEAT-ROR-W offers 1351Ffixed and rate -of -rise thermal detection. • SK-HEAT-HT-W provides fixed high -temperature detection at 190°F. FEATURES AND BENEFITS • Designed to meet UL 268 7th Edition • Sleek and stylish contemporary design • Advanced thermal technologyfor fast response • Fixed temperature model (SK-HEAT-W) factory preset to 135°F (57°C) • Rate -of -rise model (SK-H EAT-RO R-W), 15°F (8.3°C) per minute • High temperature model (SK-HEAT-HT-W) factory preset to 190°F (88°C) • Addressable by device • Rotary, decimal addressing (Refer to the Silent Knight panel manuals for device capacity) Two -wire SLC connection • LEDs blink every time the unit is polled • 3601-field viewing angle of the visual alarm indicators (two bi-color LEDs); LEDs blink green in Normal condition and turn on steady red in Alarm • Integral communications and built-in device -type identification • Remote test feature from the panel • Built-in functional test switch activated by external magnet • Walk testwith address display (an address of 121 will blink the detector LED 12- (pause)-1) • Low standby current • Built-in tamper -resistant feature • Designed for direct -surface or electrical - box mounting • Sealed against back pressure • Plugs into separate base for ease of installation and maintenance • SEMS screws forwiring of the separate base • Optional remote, single -gang LED accessory • Optional sounder, relay, and isolator bases • Optional flanged surface mounting kit Honeywell SUMI- " XMGM APPLICATIONS Use thermal detectors for protection of property. For further information, refer to manual 156-6529, Applications Manual for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications. INSTALLATION The SK-HEAT-W Series plug-in intelligent thermal detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see SK-61045. Note: Because of the inherent supervision provided bythe SLC loop, end -of -line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. Note: When using relay or sounder bases, consultthe SK-ISO installation sheet 156-3627 for device limitations between isolator modules and isolator bases. PRODUCT LINE INFORMATION SK-HEAT-W: White, low -profile intelligent 135°F fixed thermal sensor SK-HEAT-ROR-W: White, low -profile intelligent rate -of -rise thermal sensor SK-HEAT-HT-W: White, low -profile intelligent 1901Ffixed thermal sensor 13300-6: White, standard flanged low -profile mounting base B300-6-BP: Bulk pack of B300-6, package contains 10 B300-6-IV: Ivory, standard flanged low -profile mounting base B501-WHITE: White, standard European flangeless mounting base B501-BL: Black, standard European flangeless mounting base B501-IV: Ivory, standard European flangeless mounting base B501-WHITE-BP: Bulk pack of B501-WHITE, contains 10 B200S-WH: White, Intelligent, programmable sounder base B20OS-IV: Ivory, Intelligent, programmable sounder base B200SR-WH: White, Intelligent sounder base for retrofit applications B200SR-IV: Ivory, Intelligent sounder base for retrofit applications B200S-LF-WH: White, Low Frequency Intelligent, programmable sounderbase B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounderbase B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications B224RB-WH: White, plug-in System Sensor® relay base B224RB-IV: Ivory, plug-in System Sensor relay base B224BI-WH: White, plug-in System Sensor isolator detector base B224BI-IV: Ivory, plug-in System Sensor isolator detector base ACCESSORIES TR300: White, replacement flange for B210LP or B300-6 bases TR300-IV: Ivory, replacement flange for B21OLP or B300-6 bases RA100Z(A): Remote 3 - 32 VDC LED annunciator, mounts to a U.S. single -gang electrical box, for use with B501 and B300-6 bases only M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: White, detector color kit, pack of 10 CK300-IV: ivory, detector color kit, pack of 10 CK300-BL: Black, detector color kit, pack of 10 Page 2 of 3 — 351637:3. 7/1/2019 SK-HEAT-W SERIES TECHNICAL SPECIFICATIONS PHYSICAUE=NVIRONME=NTAL AGENCY LISTINGS AND Size: 2.0" (5.3 cm) high; base determines APPROVALS diameter These listings and approvals apply to the -B300-6: 6.1(15.6 cm) diameter modules specified in this document.ln some -B501: 4" (10.2 cm) diameter cases, certain modules or applications may not be listed bycertain approval agencies, or For a complete list of detector bases, see listing may be in process. Consult factory for SK-61045. latest listing status. Operating temperature range: SK-HEAT-W, UL Listed: 56228 SK-HEAT-ROR-W: -4°F to 100°F FM Approved (-20°C to 38°C) CSFM: 7270-0559:0511 S K-H EAT-HT-W: -4° F to 150°F (-20° C to 66°C) Detector spacing: U L approved for 50 ft. (15.24 m) center to center; FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing Relative humidity: l0%— 9311/h non - condensing Thermal ratings: Fixed -temperature set point 135°F (571C), rate -of -rise detection 151F(8.310 per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak Standby current (max. avg.): 200uA @ 24 VDC (one communication every 5 seconds with LED enabled) LED current (max.):4.5mA @ 24 VDC ("ON") Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.siLentknig ht.co rn 351637 1 B 1 07/19 O= 2019 Honeywell International Inc. Honeywell ®SILENT' KMGHT MOISTURE PROOF HEAT DETECTORS CR/CF-MP SERIES Description The CR and CF-MP Series Moisture Proof Detectors are designed for hazardous locations and Moisture Proof applications. Each Moisture Proof detector is available in single or multiple circuits with open and/or closed contact configurations, and any of the fixed temperature settings including 135, 165, 200 and 285 degrees Farenheit. The Moisture Proof detector is characterized by a black phenol -plastic seal plate and black and white pigtail connections. It is specified for use in high humidity environments and areas that are subject to corrosive elements or spray washing. The suffix "MP" denotes "Moisture Proof'. C R-135MP The Model CR-135MP is a combination Rate -of - Rise and Fixed Temperature detector. A set of normally open contacts will close when the ceiling temperature increases at a (minimum) rate of 8.4°C (15'F) per minute. Closing the contacts initiates the fire alarm sequence. Independent of the rate -of -rise operation, the fixed temperature portion consists of a spring -loaded plunger retained by a fusible alloy that releases when the ceiling temperature reaches 1357 (57°C). When released, the plunger strikes the contacts and holds them closed. Spacing on an uninterrupted ceiling is 70 ft. (21.3m) for the rate -of -rise; 40 ft. (12.2m) for the fixed temperature portion. Features • Dual Action Rate of Rise & Fixed Temperature • Detects Rate of Ambient temperature rise of 8°C (15°F) • Detectors operating on fixed temperatures are only available in two settings of 135°F (57°C) or 200°F (93°C) • Clear -anodized aluminium finish CF-135MP The Model CF-135MP is a Fixed Temperature Only detector. The fixed temperature portion consists of a spring -loaded plunger retained by a fusible alloy that releases when the ceiling temperature reaches 135°F (57C). When released, the plunger strikes a normally open set of contacts and holds them closed. Spacing on an uninterrupted ceiling is 40 ft. (21.3m). The CF-135MP is identified by a black dot on its heat collector fin. CR-20OMP The Model CR-20OMP is a combination Rate -of -Rise and Fixed Temperature detector that operates in the same way as the CR-135MP, with the exception that the fixed temperature portion releases when the ceiling temperature reaches 200°F (93°C). Spacing on an uninterrupted ceiling is 70 ft. (21.3) for the rate -of -rise, and 25 ft.(7.6m) for the fixed temperature portion (a reduced spacing parameter from the CF- 135MP). The CR-20OMP is identified by a white dot on its heat collector fin. CF-20OMP The Model CF-20OMP is a Fixed Temperature Only detector. The fixed temperature portion releases when the ceiling temperature reaches 200°F (93°C). Spacing is 25 ft., (7.6m). The CF-20OMP is identified by a black dot and a white dot on the heat collector fin. CATALOGUE NUMBER • NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Contact Configurations Any Detector in the Moisture Proof Series is available in Normally Open (by far the most common) or Normally Closed, or Multiple Circuit configurations. The Model Number does not reflect the Normally Open configuration, however the letter "C° denotes Normally Closed. For example: "CR 135 C MP" describes a rate -of -rise 1 fixed temperature detector, fusing at 1357., with Normally Closed contacts, assembled with the moisture proof seal plate. Specifications Contact Rating 3A @ 125 VAC 1A @ 28 VDC 0.3A @ 125 VDC 0.1 A @ 250 VDC Ordering Information Engineering Specifications The CR & CF Series Moisture Proof detectors shall be installed in areas where corrosive elements exist or washing of walls and ceiling surfaces is commonplace. The fixed temperature portion and the rate -of -rise operation shall be determined by the ambient temperature. The Moisture Proof detectors shall be installed in areas where environmental conditions including dust, vapours, insects, etc., would cause an ionization or photoelectric type detector to initiate a false alarm. Dimensions Diameter: 5.25" (13.4 cm) Height: 2.0" (4.85 cm) Weight 0.41 lb. (330 gm) CR-135MP Rate of Rise & Fixed Temperature to 1350F 57°C Moisture Proof Heat Detector Rate of Rise & Fixedempera ure to Moisture Proof Heata ec or CF-135MP Fixed Temperature 135OF (57°C) Moisture Proof Heat Detector CF-20OMP Fixed Temperature 200OF (93°C) Moisture Proof Heat Detector A/4,1". MI RcoM Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 Web page: http:l/www.mircommom NOT TO BE USED FOR INSTALLATION PURPOSES. U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Email: mail@mircom.com Distributed by: ISO 9001.2000 ire REGISTERED CAT. 5108 Re 4 SYSTEM SENSOR' C01224 Series Carbon Monoxide Detectors with RealTest° Technology The System Sensor CO1224T, CO1224TR and CO1224A (Canada) Carbon Monoxide (CO) Detectors use a highly accurate and reliable electrochemical sensing cell to provide early warning of dangerous CO levels. Features • A 10-year end -of -life timer • RealTest@ enables a functional test using canned CO • A code -required trouble relay • Wiring supervision with SEMS terminals • 12/24 VDC • A low current draw of 20 mA in standby and 40 mA in alarm • Versatile mounting for wall and ceiling • Accurate and reliable electrochemical sensing technology • Optional CO -PLATE CO Detector Replacement Plate to upgrade previously installed competitor detectors to the C01224T or C01224A. • C01224T tested up to 12,000 feet above sea level Agency Listings UNote: C01224T & L C01224TR are in full compliance with UL L 2075 and C01224A Lisri:n is ea LISTED saoao7s in full compliance with ULC CSA 6.19-01. C01224A C01224T When dangerous amounts of CO are detected, the C01224 Series CO detectors alert residents by sounding and flashing a temp 4 signal alarm. With 24/7 central station monitoring, residents are guaranteed protection whether they are away from home, sleeping, or already suffering from the effects of CO. The CO1224 Series detectors are designed for system operation. These detectors are fully listed to UL 2075 (US models only) and CSA 6.19-01 (Canada model only) and offer a code -required trouble relay to send a sensor failure or end -of -life signal to the control panel and the central station. The C01224 Series detectors also use SEMS-type terminal Philips head screws for quicker and more positive wiring connections and code -required wiring supervision. With a low current draw, these detectors enable more devices to be connected to the panel, limiting the need to purchase extra power supplies or more expensive panels. As 12124 VDC detectors, the C01224 Series detectors will operate on most industry security and fire alarm control panels. With RealTest technology, the CO gas sensing cell used in the CO1224 Series CO detectors can be tested using a CO gas agent, fully meeting the requirements of NFPA 720: 2009 (US models only). Simply put the detector into RealTest mode, spray a small amount of CO into the detector per the installation instructions, and within seconds the detector will alarm, indicating successful gas entry. (See the reverse page or the user manual for complete instructions.) C01224 Series Detectors Carbon Monoxide Detector Specifications Carbon monoxide (CO) detector shall be a system -connected System Sensor model number C01224T or C01224TR listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors. The Canadian model C01224A, is ULC listed to CSA 6.19-01, for residential carbon monoxide alarm devices. The detector shall be equipped with a sounder and a trouble relay. The detector's base shall be able to mount to a single -gang electrical box or direct (surface) mount to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide dual -color LED indication that blinks to indicate normal standby, alarm, or end -of -life. When the sensor supervision is in a trouble condition, the detector shall send a trouble signal to the panel. When the detector gives a trouble or end -of -life signal, the detector shall be replaced. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. For the C01224T only, the detector shall perform in the detection of CO up to 12,000 feet above sea level and alarm within the time specified by ANSI/UL 2034 for CO concentrations of 70, 150 and 400 parts per million (ppm), as verified by a Nationally Recognized Test Laboratory. Operating Voltage 12J24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA (75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0-5 A @ 30 VDC Physical Specifications Size: C01224T & C01224A Length: 5.1 in (130 mm), Width: 3.3 in (84 mm), Height: 1.3 in (33 mm) Size: C01224TR Diameter: 6.0 in (152 mm), Height: 1.3 in (33 mm) Approximate Weight C01224T & CO1224A: 7 oz (198 g); CO1224TR: 11 oz (312 g) Operating Temperature Range 32'F to 104' F (0�C to 40' C) Operating Humidity Range 22 to 90% RH InputTerminals 14 to 22 AWG Mounting Single -gang back box; surface mount to wall or ceiling Operation Modes Operation Normal (standby) Blink 1 per minute — — Alarm — Blink in temp 4 pattern Sound in temp 4 pattern RealTest" Feature: The System Sensor C01224 Series CO Detectors enable evaluation ofthe functionality of the CO sensing cell using a canned CO test agent NOTE: Check with local codes and the AHJ to determine if a functional gas test is desired for an installation. Push and hold the Testy lush button for Spray canned CO agent into the Verity CO sensing at the control panel. two seconds to enter RealTest mode. The detector. The detector will automatically exit green LED will flash once every second to RealTest alarm mode after about 20-60 indicate RealTest mode has started. seconds. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes (except in RealTest mode). Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. End -of -Life Timer: After the detector's internal sensor has reached the end of its life, a trouble signal will be sent to the panel to indicate it is time to replace the detector. An electrochemical CO detector lifespan is about ten years. The detector must be replaced by the date marked on the inside of the product. CO -PLATE: System Sensor also offers the CO -PLATE CO Detector Replacement Plate to cover the footprint (when necessary) of previously installed competitive carbon monoxide detectors that require replacement. 0 Ordering Information CO -PLATE C01224T 12/24 volt, 6-wire system -monitored carbon monoxide detector with RealTest® Technology (US only) C01224TR 12124 volt, 6-wire system -monitored round carbon monoxide detector with RealTiese Technology (US only) CO -PLATE CO detector replacement plate to cover the footprint of previously installed competitive detectors (US & Canada) SYSTEM US: 3825 Ohio Avenue Canada: 6581 Kitimat Rd, Unit 6 *2016 System Sensor. Product specifications subject to SENSOR St. Charles, 11160174 800-SENSOR2 Mississauga, Ontario L5N 3T5 800-SENS0A2 change without notice. If;!,ourwebsites for current product information, including the latest version of this data sheet. systomsensor.com systemsensotoa. CODS88600 • tot% SILENT SK-Pull-SA and SK-Pull-DA KNIGHT Intelligent Pull Stations by Honeywell The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only one motion to activate the station. The SK-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition • Dual -color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) • Meets ADA requirement for 5 Ibs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® • Reliable analog communications for trouble -free operation • Braille text on station handle • Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled • Rotary address switches for fast installation • UL Listed, including UL 38, Standard of Manually Actuated Signaling System II -SA SK-Pull-DA Compatibility The SK-Pull-SA and SK-Pull-DA are compatible with the following IntelliKnight FACP's: 5600 5700 5808 5820XL 5820XL-EVS Model SK-Pull-DA and SK-Pull-SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans, Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. IN SLC OUT Comp Wiring SK-Pull-SA & SK-Pull-DA Pull Stations Specifications Physical Height: 5.5 (14 cm) Width: 4" (10.2 cm) Depth: 5.4 oz. (3.7 cm) Housing Material: LEXAN polycarbonate resin Bi-Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (NIO) switch which closes upon activation of the pull station Electrical Operating Voltage: 15-32 VDC Average Operating Current (LED flashing): 300 pA Wire Gauge: Up to 12 AWG (3.1 mm2) Environmental Operating Temperature 321 -- 120°F (0°C -- 49°C) Humidity: 10% -- 93% non -condensing Accessories BG-TR Optional trim ring. SB-1/0 Surface backbox SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover 0 KNIGHT all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com MADE IN AMERICA FORM# 350135 Rev C © 2013 Honeywell International Inc. SILENT KNIGHT by Honeywell SK-Minimon Intelligent Mini Monitor Module The SK-Minimon addressable mini monitor modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SK-Minimon is designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description The SK-Minimon is an addressable monitor modules for use with the IntelliKnight fire alarm control panels (FACPs). The SK-Minimon acts as an interface to contact devices, such as waterFlow switches and pull stations. The SK-Minimon supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions The SK-Minimon can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. Features • Single contact monitor • SK-Minimon support for Class B (Style B) contact monitor wiring • Small and lightweight size allows for flexible mounting options • Rotary address switches for fast installation • UL listed SK-Minimon Specifications Electrical Standby Current: 400 uA max @ 24 VDC with comm. Voltage Range: 15 - 32 VDC End of Line Resistance: 47 k Ohms Physical Dimensions: 2.75" W x 1.3" H x 0.5" D Weight: 1.2 oz (37 g) Environmental Operating Temperature: 32°F — 120°F (0°C — 49°C) Humidity: 10% — 93% non -condensing Compatibility The SK-Minimon is compatible with the following IntelliKnight Systems: 5820XL 5820XL-EVS 5808 5700 5600 (Rev 2.0 or higher) SK-FFT Listings UL CSFM FM SK-Minimon Intelligent Monitor Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable monitor modules Silent Knight SK-Minimon. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SK-Minimon shall be installed inside a single gang junction box directly behind the monitored unit. IN SLc OUT compati Wiring the SK-Minimon Other Devices SILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA KNIGHT to keep our product information up-to-date and accurate. We cannot cover FORM# 350133 Rev E all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent cO 2013 Honeywell International Inc by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203)484-7118. For Technical Support, Please Call 800-446-6444. www.silentknight.com CABLE SPECIFICATIONS DESCRIPTION CONDUCTOR INSULATION COLOR CODE LAY LENGTH SHIELD DRAIN WIRE JACKET JACKET COLOR MARKING OVERALL DIAMETER CABLE WEIGHT CAPACITANCE IMPEDANCE DC RESISTANCE TEMPERATURE RATING INDUSTRY STANDARDS FLAME RATING AGENCY APPROVALS SRRARTWIRE 16 AWG 2 Conductor twisted Bare Copper, Non -Shielded Plenum Fire Alarm, FPLP (UL) 16 (Solid Bare Copper) Low -Smoke PVC .010" Black/Red 3.5" LHL (approx. 3.4 TPF) N/A N/A Low -Smoke PVC .018" Red Jacket FIRE/LIFE SAFETY CONTROL CABLE INIT. / IND. DEVICE / ZONE A B C D E 0 1 2 3 4 5 6 7 8 9 16 AWG FPLP (UL) ROHS MADE IN THE USA .178" Nom 26 Lbs/Mft. 26 pF/Ft. Nom. 72 Ohms/Mft. 4.10 Ohms/Mft @ 20 deg. C 0 C to 75 C / 300 Volt Approved For Plenum Use Without Conduit Per NFPA 262 Flame Test NEC Article 800, 760; FPLP (UL), RoHS Compliant, Made in the USA IrfAOE iNl AMER All specifications referenced are nominal measurements unless otherwise noted. CABLE SPECIFICATIONS DESCRIPTION CONDUCTOR INSULATION COLOR CODE LAY LENGTH SHIELD DRAIN WIRE JACKET JACKET COLOR MARKING OVERALL DIAMETER CABLE WEIGHT CAPACITANCE IMPEDANCE DC RESISTANCE TEMPERATURE RATING INDUSTRY STANDARDS FLAME RATING AGENCY APPROVALS SMARTWIRE 4GL�Q T E C H N❑ L O G Y 14 AWG 2 Conductor twisted Bare Copper, Non -Shielded Plenum Fire Alarm, FPLP (UL) 14 (Solid Bare Copper) Low -Smoke PVC .010" Black/Red 3.75" LHL (3.2 TPF) N/A N/A Low -Smoke PVC .018" Red Jacket with White Stripe FIRE/LIFE SAFETY CONTROL CABLE INIT. / IND. DEVICE / ZONE A B C D E 0 1 2 3 4 5 6 7 8 9 14 AWG FPLP (UL) ROHS MADE IN THE USA .206" Nom 36 Lbs/Mft. La Lr 26 pF/Ft. Nom. 72 Ohms/Mft. 2.57 Ohms/Mft @ 20 deg. C 0 C to 75 C / 300 Volt r 11 A H Approved For Plenum Use Without Conduit Per NEC Article 800, 760; FPLP (UL), RoHS Compli U� All specifications referenced are nominal measurements unless otherwise noted.