Loading...
FIR2021-0109+Fire_Alarm_Plan+9.23.2021_2.48.33_PM+2425916A B C D E F G IT I I TYPICAL MOUNTING HEIGHTS GENERAL SYSTEM NOTES PANEL: 1. THE FIRE ALARM CONTROL PANEL (FACP) IS TO BE MOUNTED TO THE FINISHED CEILING SURFACE. THE TOP OF THE PANEL SHALL NOT EXCEED 6 FEET ABOVE FINISHED FLOOR SURFACE. A MINIMUM CLEARANCE OF 36" WORKING SPACE WALL MOUNT CEILING MOUNT CEILING MOUNT -STROBE -STROBE -SMOKE DETECTOR SHALL BE MAINTAINED. -HORN STROBE -HEAT DETECTOR -HORN STROBE WE -HEAT DETECTOR WP 2, THE SUPPLEMENTAL NOTIFICATION APPLIANCE CONTROL PANEL (SNAG) IS -CO DETECTOR TO BE MOUNTED SURFACE, BESIDE THE FACP. THE TOP OF THE PANEL SHALL NOT EXCEED 6 FEET ABOVE FINISHED FLOOR SURFACE. A MINIMUM CLEARANCE OF 36" WORKING SPACE SHALL BE MAINTAINED. 3THE SNAG IS TO BE POWERED BY THE SAME DEDICATED 120 VAC CIRCUIT AS THE FACP. TWO CONDUCTORS TO 120 VAC, ONE CONDUCTOR TO ISOLATED GROUND, 20 AMP DEDICATED CIRCUIT. A HOUSE GROUND WILL NOT BE ACCEPTABLE. CONTROL MANUAL FARA THE BOTTOM OF THE FACP NOR THE SNAG SHALL BE PANEL PULL PENETRATEDR O STATION DEVICES: E] 1, ALL MANUAL PULL STATIONS SHALL HAVE THE TOP OF THE STATION AT F 48 INCHES ABOVE THE FINISHED FLOOR. 80" 60" 48" 60" 2. ALL SIGNALING DEVICES SHALL HAVE THE BOTTOM OF THE DEVICE PLACED AT 80 INCHES ABOVE FINISHED FLOOR WITHIN THE SPACE, OR THE TOP OF THE DEVICE 6 INCHES BELOW THE CEILING, WHICHEVER IS LOWER. 3. THE AUDIBLE DEVICES SIGNAL SHALL BE SET TO THE TEMPORAL SETTING, 4. ALL DEVICES ARE TO BE LOCATED PER THE DRAWINGS. FINISHED FLOOR 5. WHEN APPLICABLE, VERIFY WITH MECHANICAL CONTRACTOR THE EXISTENCE AND LOCATION OF ALL MOTORIZED SMOKE DAMPERS. THESE ARE TO BE 120 VAC DEVICES ON AS FEW CIRCUITS AS POSSIBLE. THESE DEVICE CIRCUITS ARE TO BE CONTROLLED BY THE FACP THROUGH AN INTERFACING RELAY. 6. WHEN APPLICABLE, VERIFY WITH SPRINKLER CONTRACTOR ALL LOCATIONS OF THE SPRINKLER WATERFLOW, DRY FLOW, HI/LO AIR, TAMPER SWITCHES AND PIV OR 0, S, & Y VALVES. 7. WHEN APPLICABLE, VERIFY WITH SPRINKLER CONTRACTOR THE EXISTENCE OF SPRINKLER HEAT TAPE. THIS HEAT TAPE SHALL BE MONITORED BY THE FACP AND SHALL REQUIRE AN APPROPRIATE RELAY THAT WILL PROVIDE SUPERVISION FOR HEAT TAPE GROUND FAULTS AND LOSS OF PRIMARY POWER. 8. WHEN APPLICABLE, VERIFY WITH SPRINKLER CONTRACTOR THAT ALL APPLICABLE INTERSTITIAL CEILING, ATTIC, OR FLOOR SPACES ARE PROTECTED WITH SPRINKLER HEADS. 9. ALL SPRINKLER WATERFLOW ZONES SHALL BE NON-SILENCEABLE PER U.L. 864. THE CONDITION MUST BE RETURNED TO A NORMAL CONDITION BEFORE THE FACP CAN BE SILENCED. WIRING: 1. TWO DEDICATED PHONE LINES TO BE INSTALLED BY OWNER TO TRANSMITTER. 2. ALL AUDIBLE / VISUAL CIRCUITS ARE TO BE 14 AWG FPL WIRE. (RISER OR PLENUM RATED WIRE WHERE REQUIRED PER NEC). 3. AUDIBLE / VISUAL CIRCUITS ARE TO HAVE AN END OF LINE RESISTOR (ELR) AS APPROPRIATE WITH THE FACP / SNAG. 4. THE DETECTION COMMUNICATION LOOP IS TO BE 16 AWG TWISTED, NON -SHIELDED, MID -CAP FPL WIRE. (RISER OR PLENUM RATED WIRE WHERE REQUIRED PER NEC). 5. THE DETECTION COMMUNICATION LOOP DOES NOT REQUIRE AN ELR AT THE END OF THE CIRCUIT. 6. WIRE TO WEATHERPROOF DEVICES SHALL BE STUBBED OUT ONLY. SURFACE WEATHERPROOF BACK BOXES SHALL BE PROVIDED WITH DEVICES, 7. ALL FIRE ALARM WIRES ARE REQUIRED TO BE IDENTIFIED AND APPROPRIATELY MARKED. S. PER NEC, NO AC VOLTAGE WIRING OF ANY KIND SHALL BE RUN IN THE SAME CONDUIT OR RISER AS THE LOW VOLTAGE FIRE ALARM SYSTEM WIRING. 9. ALL JACKETED CABLE MUST INCLUDE A JACKET REMOVAL PULL STRING AS PART OF THE CABLE. 10. SHIELDED CABLE IS NOT AN ACCEPTABLE SUBSTITUTION FOR CABLE WITHOUT "SHIELDED" AS PART OF THE DESCRIPTION. GENERAL: 1. ALL FIRE ALARM JUNCTION BOXES ARE TO BE PAINTED RED. 2. ALL END OF LINE DEVICES SHALL HAVE AN IDENTIFYING E.O.L. STICKER AT THE E.O.L. LOCATION. 3. ONLY CONDUCTORS INTENDED FOR TERMINATION TO THE SPECIFIC DEVICE ON ANY GIVEN JUNCTION BOX SHALL BE LEFT OPEN FOR TERMINATION IN THAT JUNCTION BOX. ALL OTHER CONDUCTORS SHALL PASS THROUGH, OR BE SPLICED THROUGH, THAT JUNCTION BOX. WARRANTY ALL EQUIPMENT AND LABOR PROVIDED BY ABSCO SOLUTIONS, INC. HAS A WARRANTY OF ONE YEAR FROM DATE OF INVOICE. THIS WARRANTY EXCLUDES ALL COVERAGE FOR CONSEQUENTIAL DAMAGES, AND IS GIVEN IN LIEU OF ALL OTHER EXPRESS WARRANTIES OR IMPLIED WARRANTIES OF FITNESS, HABITABILITY, OR MERCHANTABILITY OTHERWISE PROVIDED UNDER THE LAWS OF WASHINGTON. ANY WARRANTY WORK PERFORMED BY ABSCO SOLUTIONS, INC. DOES NOT EXTEND THE WARRANTY OF ONE YEAR FROM THE DATE OF THE INVOICE. THIS WARRANTY SHALL BE VOID IF A PERSON OR FIRM OTHER THAN ABSCO SOLUTIONS, INC. OR THE CONTRACTOR AUTHORIZED BY ABSCO SOLUTIONS, INC. PERFORMS OR RE -PERFORMS ANY WORK IDENTIFIED WITHIN THE ORIGINAL SCOPE OF THE WORK OF THE CONTRACT WITH ABSCO SOLUTIONS, INC. LEGAL NOTICE: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ABSCO SOLUTIONS, INC. ANY REPRODUCTION IN PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION OF ABSCO SOLUTIONS, INC. IS PROHIBITED. PATENT RIGHTS (WHERE APPLICABLE) COPYRIGHTS AND ALL OTHER PROPRIETARY RIGHTS ARE EXPRESSLY RESERVED BY ABSCO SOLUTIONS, INC. 0 IP C PANEL DETAIL — LOWER FLOOR FINISHED CEILING SMOKE DETECTOR To NOTIFICATION TO SLC DEVICES/CO DEVICES DETECTORS 3/4" EMT TYR. 3/4" EMT TYR. 1 2' 6 6" GUTTER 1' EMT TYP. 7I07P-88-UW RF COMMUNICATOR C� 0 Q 7 Ye" TO FARA •p 1640 T TRANSFORMER 6808 FACP FIRE AWE. DOCUMENTS TO 120VAC (BY OTHERS) FINISHED FLOOR i F I R2021-0109 RECEIVED Sep 23 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Approved by Fire ARM IGF-itterer Approved with redline changes. (Move exterior horn/strobe closer to entrance and keybox Need new Knox type keybox) F DEVICE LEGEND MANUFACTURER MODEL NUMBER DESCRIPTION BACK BOX SYMBOL QUANTITY SILENT KNIGHT 6808 ADDRESSABLE FIRE ALARM CONTROL PANEL PROVIDED FACP 1 SILENT KNIGHT 5860R ARE ALARM REMOTE ANNUNCIATOR SD-7511AHTR FFA-R-Al 1 AES 7707P-88-ULP RADIO TRANSMITTER PROVIDED RF 1 GAMEWELL-FCI GW-FAD FIRE ALARM DOCUMENT LOCKCABINET PROVIDED FFADCj 1 SYSTEM SENSOR SCRL CEIUNG MOUNT STROBE, RED DOUBLE GANG ® 1 SYSTEM SENSOR SRL WALL MOUNT STROBE, RED DOUBLE GANG ® 2 SYSTEM SENSOR P2RL WALL MOUNT HORN STROBE, RED DOUBLE GANG 5 SYSTEM SENSOR P2RK WALL MOUNT HORN STROBE, RED, OUTDOOR INCLUDES BACKBOX DOUBLE GANG WP 4 SILENT KNIGHT SK-PHOTO-W INTEW H M N 4SOR W/ 3-0 RING Q2 1 SILENT KNIGHT SK-HEAT-ROR-W AWRESSABLE PLUG-IN THERMAL DETECTOR, INCLUDES 6' BASE 4SOR W/ 3-0 RING ® 10 MIRCOM CR-135MP MMSIURE PROOF HEAT DFIECTOR 4SOR W/ 3-0 RING TWP 2 SILENT KNIGHT SK-HEAT-W-W BASE INCHUED IN SK UEYICE 41R W/ 3-0 RING QH 1 GAMEWELL-FCI C01224TR CONVENTIONAL CARBON MONOXIDE DETECTOR, 12/24 VDC WITH SOUNDER AND TROUBLE RELAY TEST FUNCTION, 00075 LISTED, ROUND 4-SOR W/ 3-0 RING © 2 SILENT KNIGHT SK-PULL-DA INTELLIGENT PULL STATION DUAL ACTION DEEP 4-SOR ❑F 1 SILENT KNIGHT SK-MINIMON ADDRESSABLE MINIATURE INPUT MODULE DEEP 4-SOR Q 4 WIRE LEGEND ABSCO DESIGNATION DESCRIPTION MANUFACTURER MODEL NUMBER NON -PLENUM MODEL NUMBER PLENUM MODEL NUMBER BURIAL A 16/2 UNSHIELDED PLENUM SOLID WINDY CITY WIRE 761360-S B 14/2 PLENUM UNSHIELDED FPLP WINDY CITY WIRE 767969-S GENERAL SYSTEM LEGEND NOTIFICATION DEVICE ID INITIATING DEVICE ID WIRE ID ABBREVIATIONS REARENCE WIRE LEGEND-ABSCO UCSGNARON E = EXISTING N1-1� L,MI N = NEW NOTIFICATION RR = REMOVE & RELOCATE DEVICE CIRCUITI OEVICE� WIRE ID Ott OF WIRE MULIIPLE TYPES/OTY W = WIRELESS NOTIFICATION DEVICEQ Cd = CANDELA RATING DEVICE TYPE C 2C 2C2B i �i 1 1 ^�A = MILUAMPS V = VOLTAGE A- Name and Address Absco Solutions P.O. BOX 2246 LYNNWOOD, WA 98036 PH: 425.771.1 166 FAX: 425.771.4422 www.abscosolutions.com Project Name and Address >_ O O N O O z0 O - � O � O O O O m O U OO O Mill LOOPN 5 ENSOR "M ELR = END OF LINE ODULE TFA= TO FLOOR ABOVE LEGAL NOTICE: THE INFORMATION TFB= TO FLOOR BELOW CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ABSCO SOLUTIONS, INC. ANY REPRODUCTION IN PART OR IN WHOLE WITHOUT THE WRITTEN PROJECT NOTES PERMISSION OF SOLUTIONS, INC. ABSCO PATEN IS PROHIBITED. PATENT RIGHTS (WHERE APPLICABLE) COPYRIGHTS AND ALL • TECHNICIAN TO AS -BUILD DEVICE ADDRESSES OTHER PROPRIETARY RIGHTS ARE • AMBIENT TEMPERATURE 70F IN ALL SPACES • AMBIENT SOUND LEVEL >40DB IN ALL SPACES E X P R E S S L Y R E S E R V E D Y B ABSCO S O L U TI O N S, I N C. Designer of R.— HEN DAY A— SOLUTIONS, INC. 9023 WOO AVE W STE E LONE: (42 WA 98036 PHONE: (425) ]J -1166 Far: (425) 7]1 -4422aa22 SEQUENCE OF OPERATIONS EMAIL: KEN.DAYBABSCOSOLUTDNSCOM NICLT: IV , 9J083 1-08/19/21 Submittal Set AP Rev. -Dale Revision By Drawn By A.P. Checked By D.H. Dale 08/17/21 Project Name YOST POOL Cltt OF EDMONDS Project Number 21272 System Type FIRE ALARM sheet Np LEGENDS, DETAILS, FIRE ALARM PLANS Sheet Number FZ001 SHEET 1 OF 3 7 R A B C D E F 5 H 7707P-88-ULP RF BATTERY CALCULATIONS 41 I I T11 I I I ■ 6808 FACP BATTERY CALCULATIONS �AbSC0 S0bjfi00S BATTERY STANDBY REQUIREMENTS JOB NAME: Yost Pool City of Edmonds v«..w.xaa.e Lm.wAmox Standby Current Alarm Current n w:�us�n1.11m s..:usslmma amps amps Qtv Code Description Each I Total Each Total 6808 FACP BATTERY CALCULATIONS �AbSC0 S0bjfi00S BATTERY STANDBY REQUIREMENTS JOB NAME: Yost Pool City of Edmonds v«..w.xaa.e Lm.wAmox Standby Current Alarm Current n w:�us�n1.11m s..:usslmma amps amps Qtv Code Description Each I Total Each Total 1 586OR IntelliKn' ht remtlreote AUX 0.02 0.02 0.025 0.025 1 6808 Silent Knl MAdssable panel PAN 0.19 0.19 0.25 0.25 2 C01224TR Conventional Carbon Monoxide INI 0.02 0.04 0.04 0.08 1 P2RK 115od WP Wall Md. Hom Strobe SIG 0 0 0.218 0.218 3 P2RK 75cd WP Wall Mint, Hom Strobe 1224 SIG 0 0 0.176 0.528 2 P2RL 15cd Wall Mnt. Hom Strobe SIG 0 0 0.054 0.108 3 P2RL 75cd Wall Mnt. Hom Strobe SIG 0 0 OA21 0.363 1 SCRL 15cd Ceiling Mnt. Strobe, Red SIG 0 0 0.041 0.041 1 SK-HEAT-HT- HI -TEMP HEAT DETECTOR BASE INI 0.0002 0.0002 0.0045 0.0045 10 SK-HEAT- Heat detector ROR - White, inUudes INI 0.0002 0.002 0.0045 0.045 4 SK-Mmimon Addressable miniature input module INI 0.004 0.016 0 0 1 SK-PHOTO-W Intelli ent DII smoke detectors. INI 10.0002 0.0002 0.0045 0.0045 1 SK-PULL-DA Intelligent Pull Station Dual Action INI 0.0003 0.0003 0.007 0.007 2 SRL 15cd Wall Mount Strobe SIG 0 0 0.043 0.086 Totals: 0.2687 1.76 NOTES: 6808 FACP 24V 12ah Battery Capacity Total Standby Current: 0.2687 Total Alarm Current: 1.76 X standby hours needed: 24.0 X fraction of hours needed: 0.083 Total: 6.4488 Total: 0.1461 Total Standby: 6.4488 +total alarm: 0.1461 Total: fi.5949 X d-factor: 1.2 Total Amp hour needed: 7.9139 FIRE ALARM RISER ---------------------------------------------------------------------------------------------- UPPER FLOOR UPPER FLOOR N2-6 ELR. 0.636mA I^'y 75cd 75cd 15cd 75cd 15cd 75cd WP UPPER FLOOR ________________________________________. LOWER FLOOR N1-6 ELR. 0.708mA 75cd 15cd 75cd 15W 115cd 15cd WP WP WP I - �l A A A I I�yA A A A A A A r V I I UPPER FLOOR LOWER FLOOR B I A A I A A A A A A A A A cm 1 1 ® � � ® L1 M 1 L1 A,B I FARA I _ 1 A TO 120VAC (BY OTHERS) X v LOWER FLOOR m-M-n o- --------------------------------------------------------------------------- m00"a LOWER FLOOR ^^ a� D T Azo W rn � m(n0 0 Z�0 O 3N rnm (1) 7 7 L S F 1 1 Firm Nome11 rd Atldress Absco Ions P.O. BOX 2246 LYNNWOOD, WA 98036 PH: 425.771,1 166 FAX: 425.771.4422 www.abscosolutions.com Project Name crd Atldress O Q N O 0 00 z o-) O EL U/ m0 W 0\T Ln^�'^Io Ln V i LLI LEGAL NOTICE: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ABSC0 SOLUTIONS, INC. ANY REPRODUCTION IN PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION OF ABSCO SOLUTIONS, INC. IS PROHIBITED. PATENT RIGHTS (WHERE APPLICABLE) COPYRIGHTS AND ALL OTHER PROPRIETARY RIGHTS ARE EXPRESSLY RESERVED BY ABSCO SOLUTIONS. INC. Designer of Record KEN DAY ABSCO SOLUTIONS, INC. 19023 36TH AVE W STE E LYNNWOOD, WA 96036 PHONE: (425) 77 1 -1166 FAX: (425) 771-4422 EMAIL KEN .OAYnABSCOSOLUTIONS We NICEr: IV It 97083 1-08/19/21 Submittal Set AP Rev.# -Date Revision By Drawn By A.R. Checked By D.H. Date 08/17/21 Project Name YOST POOL Cltt OF EDMONDS Project Number 21272 System Type FIRE ALARM Sheet Name FIRE ALARM RISER, NOTIFICATION CIRCUIT & BATTERY CALCULATIONS Sheet Number FZ002 SHEET 2 OF 3 A B D F F G H 7 UPPER FLOOR - FIRE ALARM PLAN SCALE: 1/8"=1'0" SUITE 202 PROPOSED NEW YOST POOL OFFICE (WITH ENCLOSED CEILING) A PROPOSED A CE NO A—ITY ROOM r - - - - - - - - - - - - - - - - - 1 r- - - - - - - - - - - - - B15cd 15cd ApprovedP 1 I A 1 1 ARMEXIST ST OOM OOM A,BI • TO FACP ® WP®11 1 I A I FgRA • with redlineIq 4—A-J-1 TO FACP CKT. N2 UPPER FLOOR 7xd WP ®®Approved suITE7o9 changes. (Move exteriorMIS I1 horn/Strobe Closer toTO CO DEFECTORS UPPER FLOOR,B 1 entrance and keyboxTO FARA 120VAC (BY OTHERS) uP 1TO IA A w Knox type L—__---__A--___ I keybox) - PROPOSEDCHAIN LINK GATE d I I PROPOSED 1 L — — — STORAGE WITH CEILING K�o: ema 7 d w. N1-6 PRoaosEU corvcRwALrc To NEW POOL ENTETERANCE ELR. 0.708mA LOWER FLOOR - FIRE ALARM PLAN SCALE: 1/8"=1'0" X v En �M m4 CID m5� 0 � v D En AZo W rn C �<O 0 0 3N rnm QO 7 L S F Firm Nomecd Addrese ISolutions P.O. BOX 2246 LYNNWOOD, WA 98036 PH: 425.771,1 166 FAX: 425.771.4422 www.abscosol oti-S.— >- 0 Q N 0 >0 O z O n 00 O o c0 O cm o O LnO �� �o °� LLI LEGAL NOTICE: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ABSC0 SOLUTIONS. INC. ANY REPRODUCTION IN PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION OF ABSCO SOLUTIONS, INC. IS PROHIBITED. PATENT RIGHTS (WHERE APPLICABLE) COPYRIGHTS AND ALL OTHER PROPRIETARY RIGHTS ARE EXPRESSLY RESERVED BY ABSCO SOLUTIONS, INC. Designer of Record KEN DAY ABSCO SOLUTIONS, INC. 19023 36TH AVE W STE E LYNNWOOD, WA 96036 PHONE: (425) 77 1 —1166 FAX: (425) 771-4422 EMAIL KEN .UAY_SCOSOLUTIONS COM NICEf: IV # 97083 1-08/19/21 Submittal Set AP Rev.# —Date Revision By Drawn By A.P. Checked By D.H. Dale 08/17/21 Project Name YOST POOL Cltt OF EDMONDS Project Number 21272 System Type FIRE ALARM Sheaf Nome LOWER FLOOR UPPER FLOOR FIRE ALARM PLAN Sheet Number 0101 SHEET 3 OF 3