Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FIR2021-0135+Manufacturer_Equipment_Sheets+11.30.2021_12.18.54_PM+2543880
Kidde® WHDRTM System Parameters* Controls &Detection XVTM Control System KRS-50 Control Head 87-120099-002 87-120010-000 Max Number of Corner Pulleys 50 (each line) 40 Max Cable Length 200 ft (each line) 200 ft Mnnusl Pull Max Number of Corner Pulleys 50 Release -to -Trip (each line) 40 30 Pull -to -trip line Max Length of Cable 200 ft Release -to -Trip (each line) 100 ft Pull -to -Trip line Inline w/detection cable Mechanical Gas Line Max Number of Corner Pulleys 30 16 Max Length of Cable 100 ft 50 ft Actuation Parameters 1/4" copper tubing, compression or flare fittings) Cylinder quantity & Up to 20 cylinders Up to 5 cylinders actuation line lengths 1-12 Cylinders: 106 ft max, 5 ft min 23 ft max total 13-20 Cylinders: 91 ft max, 5 ft min Min 3 ft to 1 st cylinder Fusible & Tharmnhulh Link neter_tnre Type KML, A-360, KGS, KGR, DAF A-360, KGS, KGR Max Quantity 40 (each line) 40 I Model I 60-120064-001,WK-804548-000 1 60-120064-001 1 I Max Quantity 1 4 (pigtail or terminal type) 1 2 (pigtail tvDe only) Cylinders Cylinder Flow Points Diam in) Height (in) (top of SVA WHDR-125 4 8 17 WHDR-260 8 9 22-3/4 WHDR-400S 12 12-1/4 20-3/4 WHDR-400M 12 10 26-3/16 WHDR-600 18 10 36-15/16 "T I_ Kidde Fire Systems Rectangular Duct Coverage Single ADP Duct Coverage Two ADP Duct Coverage Side A (in) Max Side B (in) 21.0 4.0 20.5 4.5 20.0 5.0 19.5 5.5 19.0 6.0 18.5 6.5 18.0 7.0 17.5 7.5 17.0 8.0 16.5 8.5 16.0 9.0 15.5 9.5 15.0 10.0 14.5 10.5 14.0 11.0 13.5 11.5 13.0 12.0 12.5 12.5 Piping Flow Demand Min Pipe Size 1-2 1/4" 1-8 3/8" 1-12 1/2" 13 - 24 3/4" 25 - 48 11. Side A Max Side B I in (mm) in (mm). 44.0 6.0 43.0 7.0 42.0 8.0 41.0 9.0 40.0 10.0 39.0 11.0 38.0 12.0 37.0 13.0 36.0 14.0 35.0 15.0 34.0 16.0 33.0 16.8 32.0 17.2 31.0 17.7 30.0 18.1 29.0 18.5 28.0 18.9 27.0 19.3 26.0 19.7 25.0 19.9 24.0 20.2 23.0 20.5 22.0 20.8 21.0 21.0 *Summary sheet for reference only. Refer to Kidde WHDR Design, Installation, Operation & Maintenance Manual P/N 87-122000-001 for complete design and installation requirements. Copyright 00 2018 Kidde-Fenwal Inc. WHDR & XV are trademarks of Kidde-Fenwal. Inc. KHrio Faro comma Ann sen;.. Q4 A.W a see n47e4 Kidde® WHDRTM Nozzle Parameters` Systems I Kidde Fire 5 y Duct see page 2 for coverage tables) Perimeter Max Diameter Max Length Nozzle Type Flows Manual Page # Up to 50" Perimeter Duct (11.78" max throw) 50" 15.91" Unlimited ADP 1 3-35 Up to 100" Perimeter Duct (11.78" max throw) 100" 31.83" Unlimited ADP (min 2) 1 ea 3-36 Greater than 100" Perimeter Duct (11.78" max throw) Refer to manual Refer to manual Unlimited ADP 1 ea 3-37 Plenum Len th Max Width Max Filters Nozzle T e Flows Manual Page # Plenum 10, 4' 'V' Bank or Single ADP 1 3-33 Appliance Cooking Area [inches Nozzle Height/Dist inches Nozzle Position Nozzle Tvpe Flows Manual Page # Range, Four -Burner 28 X 28 20 to 42 Within 9" radius of mid point R 1 3-15 Range, Low Proximity 24 x 24 16 to 20 Centered over hazard LPR 1 3-18 Griddle (with or without raised ribs) 30 X 42 13 to 48 On perimeter, aim Win 3" rad of ctr ADP 1 3-27 Fryer, Single Vat (Drip Board up to 5") 18 X 18 27 to 45 450 to 900 from horizontal F 2 3-6 Fryer, Single Vat (2 nozzle, Drip Board up to 6-1/2") 18-1/2 X 18 27-1/2 to 45 450 to 900 from horizontal (2) F 2 ea 3-7 Fryer, Single Vat (Drip Board up to 10-1/2") 14 x 14 27-1/2 to 45 450 to 900 from horizontal F 2 3-9 Fryer, Single Vat (Drip Board less than 1 ") 24 x 24 27-1/2 to 46 On or within perimeter F 2 3-10 Fryer, Single Vat - Low Prox (Drip Board up to 7-3/4") 14 X 15-1/2 12 to 24 3.5" to 13.5" offset" Min 8 flow pts on s stem LPF 2 3-12 Fryer, Split Vat (Drip Board up to 6") 14 x 15 27 to 45 450 to 900 from horizontal F 2 3-8 Fryer, Split Vat - Low Proximity (Drip Board to 6") 14 x 15 16 to 27 On or within perimeter ADP 1 3-11 Krispy Kreme Model 270 d/h Doughnut Fryer 93 x 33 22-1/2 to 29-1/2 See Table 3-11 & Fig 3-9 (8) ADP 1 ea 3-14 Wok (3" to 8" deep) 14 to 28 dia 35 to 56 2" offset from center GRW 1 3-28 Tilt Skillet / Braising Pan 24 x 24 27-1/2 to 46 Front edge, within perimeter F 2 3-29 Upright Broiler, Salamander Broiler 30-1/4 X 34 Top 4" of broiler comp See Table 3-19 ADP 1 3-20 Chain Broiler, Closed Top 28 X 29 See Table 3-24 See Table 3-24 & Fig 3-20 ADP 1 3-25 Chain Broiler, Open Top 28 X 29 See Table 3-25 See Table 3-25 & Fig 3-21 (2) ADP 1 ea 3-26 Charbroiler, Gas - Pumice, Lava, Ceramic, Synth Rock 25-1/4 X 24 30 to 48 On or within perimeter; max 2 rock layers F 2 Addendum Charbroiler, Gas - Radiant / Electric — option 1 21 X 24 24 to 48 450 to 900 from horizontal GRW 1 3-22 Charbroiler, Gas - Radiant / Electric — option 2 25-1/4 x 36 34 to 45 On or within perimeter F 2 Addendum Charcoal Broiler, Natural or Mesquite Charcoal 24 X 24 24 to 48 450 - 900; max 6" fuel depth ADP 1 3-23 Mesquite Log Charbroiler (wood chips, chunks or logs) 30 X 24 24 to 48 450 - 900; max 10" fuel depth DM 3 3-24 *Summary sheet for reference only. Refer to Kidde WHDR Design, Installation, Operation & Maintenance Manual PIN 87-122000-001 for complete design and installation requirements. Copyright ©2018 Kidde-Fenwal Inc. WHDR & XV are trademarks of Kidde-Fenwal, Inc. Kidde Fire Systems 400 Main St Ashland MA 01721