ENG2022-0218 ROW PERMITRIGHT OF WAY MINOR PERMIT
PERMIT NUMBER
City of Edmonds
. •:• • 1 1 '
. -. •.v / 425.771.0220
Description: CITY -BORINGS FOR PH 10 SEWER REPLACEMENT PROJECT
ISSUED: 05/10/2022
Address: 121 5TH AVE N EDMONDS WA 98020
EXPIRES: 11/06/2022
Permit Type: RIGHTOF WAY MINOR Permit Subtype: CITY Parcel Number: 00434400100300
NAME TYPE NAME ADDRESS PHONE
APPLICANT RUSSELL LYNCH 121 5TH AVE. N, EDMONDS WA 98020 (425)754-5866
CONTACT CITY OF EDMONDS ENGINEERING 121 5TH AVE. N, EDMONDS WA 98020 (425)754-5866
CONTRACTOR HOLOCENE DRILLING INC 11412 62ND AVE E, PUYALLUP WA 98373 (425)329-0258
OWNER EDMONDS CITY OF 250 5TH AVENUE N, EDMONDS WA 98020
FEE INFORMATION
DESCRIPTION AMOUNT PAID
CITY TECHNOLOGY FEE CHARGED PER PERMIT
$40.00 $40.00
RIGHT OF WAY MINOR PERMIT FEE
$110.00 $110.00
1111
•
REQUIREMENT TYPE
NOTES
TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City
Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification
verifying completion of the required training in their posession.
RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with
asphalt or City approved material prior to the end of the workday - No Exceptions
WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final
inspection and acceptance of the work.
INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM
24 HR NOTICE REQUIRED
INDEMNITY I
The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of
any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments
or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of
granting this permit.
THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW
ENGINEERING DIVISION
..,7TED
RELEASED BY , f DATE
/p(vl 5 j2(J�S�(5 15/10/2022
Printed: Tuesday, May 10, 2022 7:05:54 AM 1 of 2
WAY MINOR .UM PERMIT
City of • • •
Edmonds•:• •ENG2022-0218
www.cityofedmonds. ov/425.771.0220
CONDITIONS
CONDITION TYPE
ALERT RESIDENTS
ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START.
It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in
DAMAGE TO FRONTAGE
City right of Ways or Easements to City Standards caused by or occurring during the permitted
IMPROVEMENTS
project.
MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD
ESC REQUIREMENTS
REQUIREMENTS.
Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to
indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and
agents from any and all claims for damages of whatever nature, arising directly or indirectly from the
HOLD HARMLESS
issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any
requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance
provision.
SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT.
INSPECTIONS
www.mybuildingpermit.com
POTHOLING
VERIFY CLEAR BORE CROSSINGS.
RESTORE LANDSCAPE
Restore landscape to like or better conditions
Sound or noise originating from temporary construction sites as a result of construction activity are
exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on
SOUND AND NOISE
weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all
other times the noise originating from construction sites and activities must comply with the noise
limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
All utilities shall be located prior to any excavation. New locates shall be called for if at time of
UTILITY LOCATES
excavation, original locates are no longer identifiable.
INSPECTIONS
INSPECTION TYPE DATE
RESULT
COMPLETE
X-2 ENGINEERING FINAL**
Printed: Tuesday, May 10, 2022 7:05:54 AM 2 of 2
RECEIVED
of EDAM
cy °tio� May 09 2022
RIGHT OF WAY CONSTRUCTION CITY OF EDMONDS
PERMIT APPLICATION DEVELOPMENT SERVICES
DEPARTMENT
Complete and submit this Application in accordance with the Submittal
l'vc. Ise0 Requirements outlined in Right -of -Way permit Handout E63.
If any field is not applicable to your project, write "N/A" instead of leaving blank.
All fields required. Incomplete Applications will be denied.
SECTION A
General•
Project Name City of Edmonds Phase 10 Sanitary Sewer Replacement Project
Site Address or if no site address use Property Address at NW corner of project area: Location shown in proposed exploration plan figures
Associated Permits: BLD PLN ENG
• • • .• .• -
Name of Company Franchise Ordinance No:
Point of Contact
Title
Address
City
State
Zip
Phone
Email
Contractor and Authorized Agent of Owner (see note below)
Name of Company Holocene Drilling (subcontractor to Landau Associates)
Contractor Contacts During Construction
Primary Name Tyler Cartwright (Landau Associates)
Agent Name Clay Griffith
Title Staff Engineer
Title Vice President
Mobile 425-329-0258
Address 11412 62nd Ave E
Email tartwright@landauinc.com
City Puyallup
State WA
Zip 98373
Secondary Name
Phone 253-848-6500
Title
Email cgriffith@holocenedrillingine.com
Mobile
City of Edmonds Business License No: 601709741
Email
State License No: HOLOCDI044KH
x1 Contractor verifies it is currently bonded
Contractor verifies it currently has general liability insurance
NOTE: ECDC 18.6o.02o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city
engineer.
❑ Multifamily residential ❑ Commercial X City project
❑ Single family residential subdivision ❑ Single family -other ❑ Industrial
❑ Demo and rebuild or from vacant land?
❑ Other, please specify:
❑ Utility Franchise Work associated with development (check one of the above boxes as well)
❑ Traffic Control Only (no associated development)
City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021
❑ Utility Franchise Work (no associated development)
Project Description
Include an overall narrative description of the proposed work. Be specific and detailed:
Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc.
Include whether this is construction, maintenance, or repair.
Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for
underground utilities, etc.)
Landau plans to advance three exploratory borings in support of the City of Edmonds Phase 10 Sanitary Sewer _
-Replacement project. There are three sites where borings will be advanced. Site 1 is located approximately 150 ft east of _
the intersection of 9th Ave N and Edmonds St. Site 2 is located approximately 200 ft north of Walnut St in the alley _
-between 3rd Ave S and 4th Ave S. Site 3 is located approximately 150 ft east of the intersection of 9th Ave S and Maple St_
-See attached aerial imagery for more information on proposed boring locations. At each location the roadway will need to _
-be partially closed for approximately 2 to 4 hours depending on the accessibility of the boring.
RIGHT-OF-WAY
CLOSURE
AREA
TOTAL
DURATION
(Number of Months)
Sidewalk 72 hours +
LF
JxJ
LF
SF
Alley 72 hours +
LF
JxJ
F
SF
Parking 72 hours +
LF
JxJ
LF
SF
SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C.
1. The work in the right of way is on or for the following type of facilities:
❑ telecommunications ❑ cable ❑ power ❑ gas
❑ water )0 sewer ❑ storm
Details
1.
of Work to be Completed
Does the utility owner have existin overhead infrastructure in the area of work?
Yes
X
No
2.
Will any equipment be added underground or above ground (e.g. pedestals, vaults, etc.)?
X
If yes, describe: 1 monitoring well in each exploratory boring
3.
Does the proposed work connect a lot or commercial development with utilities that serve more
than one lot or commercial development?
X
4.
Does the work involve rebuilding or relocating an existing aboveground utility system which
connects a lot or commercial development to an existing underground common utility system?
X
5.
Does the work involve proposed additions to an aboveground utility system? If es:
X
Are the additions for the purpose of serving new commercial development?
Are the additions for the purpose of serving a single-family residential subdivision?
Details of • to be Completed
Me
6. Does your project involve rebuilding or replacing utility equipment which currently serves more
than one lot or commercial development?
X
City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021
If yes, answer the following questions related to project area, i.e. the actual area in which the
project is proposed:
6a.
Does your project involve wires/cables/lines? If yes:
X
How many are existing? I I How many are to be added?
6b.
Does your project involve poles? If yes:
X
How many poles are existing in the project area?
What is the height of the existing poles?
How many poles are to be removed?
Are additional poles to be laced?
How many? I I What is the height of the additionalpoles?
6c.
Are any poles to be modified/rebuilt/replaced? If yes:
X
How many? I I What is the height of the poles after?
Describe the modification rebuild:
SECTION C
Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as
required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have
certification verifying completion of the required training in their possession.
Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be
patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS.
Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to
any permit approval.
Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials,
officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever,
foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or
omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose
acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and
specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any
respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the
expiration, revocation, or termination of any resulting permit approval.
Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and
requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to
the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal
Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable
requirements of state and federal law.
Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a
licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by
owner to act on its behalf and have authority to bind the owner to this application.
Fees. The Applicant is responsible for all permit fees.
APPLICANT SIGNATURE:
4/28/2022
APPLICANT PRINTED NAME:
Tyler Cartwright
APPLICANT TITLE: Staff Geotechnical EIT
NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE
City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021
www.invarion.com
Legend
• Cone
It Flagger
i Sign Stand
® Work Area
Sign Spaci
200' +/-
Sign Spaci
200' +/-
Sign Spacing:
200'+/-
N
Site 1
ENGINEERING DIVISION
A,..,7TED
p(� 15/09/2022
Sign Spacing: Sign Spacing:
Applicant shall repair/replace all
50' - 100' 50' - 100'
.Downstream. Flagger
Taper Taper
200' +/- O
200' +/_
I
damage to utilities or frontage
improvements in City right-of-way
,1
per city standards that is caused or
occurs during the permitted project.
�
• o
°
Edmonds St
OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING
Sign Spacing:
ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY
200'+/-
Westbound traffic
UTILITIES MAY REQUIRE A SEPERATE PERMIT.
on Edmonds takes
Sign Spacing:
priority to reduce
p 00 • +/_
��
impacting intersection16
o
OWNER/CONTRACTOR IS RESPONSIBLE FOR
RonD
EROSION CONTROL AND DRAINAGE
Z WORK
Sign Spacing:
200' +/-
Sign Spacing:
200' +/-
Flagger stations shall be
illuminated at night. worsK
AHEAD
Contractor: Landau Associates Drawn By: Andrea Sepulveda Notes:
- Maintain minimum 10' travel lanes.
Location: 9th Ave N & Edmonds St, (360) 909-6933 - Signs & supports shall not be placed in areas
Edmonds, WA 98020 designated for bikes/pedestrians.
OR TCS #05444 -All signs & devices shall conform to MUTCD
Date: April 25,2022 WA TCS#010241 standards.
Contact: Tyler Cartwright (425) 329 - 0258 Work Hours:
Job #: ---
DRAWING NOT TO SCALE
ADJUST TO FIELD CONDITIONS
CITEGRiTY
TRAFFIC
RECEIVED
To book traffic control,
call dispatch ext. 3
May 09 2022
(503) 502-5339
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Legend
• Cone
Flagger
i Sign Stand
® Work Area
Flagger stations shall be
illuminated at night.
Remove all parking
Fadjacent to work zones
to maintain minimum
DRAWING NOTTO SCALE
ADJUSTTO FIELD CONDITIONS
Sign Spacing:
100' +/-
a
I
I
Sign Spacing:
100'+/-
I —
w
fD Flagger to act as
�' spotter and facilitate
traffic in driveway
I — •
I a
Sign Spacing: .
200' +/-
I— — — Walnut St- — — — — — — — — Walnut St — — — —
Sign Spacing:
200'+/-
W
Q
IF ALLEY WILL BE CLOSED -
`� NOTIFY POLICE AND FIRE
MINIMUM OF 48 HOURS PRIOR
TO START OF WORK.
COORDINATE WITH TRASH
HAULERS.
Contractor: Landau Associates Drawn By: Andrea Sepulveda Notes:
Maintain minimum 10'travel lanes.
Location: 3rd Ave S & Walnut St, (360) 909-6933 Signs & supports shall not be placed in areas
Edmonds, WA 98020 designated for bikes/pedestrians.
OR TCS #05444 -All signs & devices shall conform to MUTCD
Date: April 25, 2022 WA TCS #010241 standards.
Contact: Tyler Cartwright (425) 329 - 0258 Work Hours:
Job #: ---
ww varion.com
Site 2
s
N
A
li\IEiF21TY
I FPAQ-IL
To book traffic control,
call dispatch ext. 3
(503) 502-5339
www.invarion.com
Legend
• Cone Flagger stations shall be Rono
?� Flagger illuminated at night. Heno
I
i Sign Stand
®Work Area Sign Spacing:
200' +/-
ONE LANE
ROAD AHEAD
Sign Spacing:
200' +1-
S
D
• ur
Sign Spacing:
200' +/-
Maple St
Sign Spacing: _ Sign Spacing:
200'+1- 200'+/-
DRAWING NOT TO SCALE
ADJUST TO FIELD CONDITIONS
ONE LANE
ROAD AHEAD
Westbound traffic
on Maple St takes
priority to reduce
impacting intersection
50' - 100' 50' - 100'
I. Flagger
Sign Spacing: Taper Taper
Sign Spacing: 200'+/-
200'+/-
4
m
ONE LANE
ROAD AHEAD
Sign Spacing: Sign Spacing: Sign Spacin 0
s
200'+1- 200'+1- 200'+1- D
O• REPAREo m
E Rono
PTO STOP WORK y
AHEAD
Maple St
Sign spacing: ONE LANE
200' +/-
ROAD AHEAD
Contractor: Landau Associates
Drawn By: Andrea Sepulveda
Notes:
Maintain minimum 10' travel lanes.
Location: 9th Ave S & Maple St,
(360) 909-6933
- Signs & supports shall not be placed in areas
CITEGRiTY
Edmonds, WA 98020
designated for bikes/pedestrians.
OR TCS #05444
-All signs & devices shall conform to MUTCD
TRAFFIC
Date: April 25,2022
WA TCS#010241
standards.
Contact: Tyler Cartwright (425) 329 - 0258
Work Hours:
To book traffic control,
call dispatch ext. 3
Job #: ---
(503) 502-5339
0
D
m
CD
N
Site b
Tr
Project Site 1 +
Proposed Exploration Planigir-
•^ •asp �.., .....��- .-
•
- O �
0 01.--@ y U o0 • 1 • •
Oki
-►�`� ~T ���'� =�' ENGINEERING DIVISION
•�-'`.r :',t ��� OWNER/CONTRACTOR IS RESPONSIBLE FOR ZA�'•
.;ate EROSION CONTROL AND DRAINAGE _ 15/09/202
• `!•� ���'_- -lam �•4
- OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING Applicant shall repair/replace all
ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY damage to utilities or frontage
J, • ~ improvements in City right-of-way
it UTILITIES MAY REQUIRE A SEPERATE PERMIT. per city standards that is caused or
•tti-�, �� occurs during the permitted project. • �, �� i•;'
w �•i�{'r+►, s• Cam. ��� ..�,•� ��!'• •� ^'��J•��'' _
Legend
Site 1 Boring
RECEIVED
May 09 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
w"I
3p
cB
(WAD,
LU
0
CL
ui
lie
(D
co
C\j
U)
Ll
e.j:v
'1 ON
Are, I.
rd
IF9
April 28, 2022
City of Edmonds
121 5th Avenue North
Edmonds, Washington 98020
Re: Right -of -Way Construction Permit Application
City of Edmonds Phase 10 Sanitary Sewer Replacement Project
Edmonds, Washington
Dear Permitting Staff:
LANDAU
ASSOCIATES
RECEIVED
May 09 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Landau Associates (Landau) is requesting review and approval of the attached right-of-way (ROW)
permit application and traffic control plan for the City of Edmonds proposed Phase 10 Sewer
Replacement Project. Mike DeLilla is the City's project manager for this project. Landau plans to
advance three shallow auger borings at the locations shown on the attached figures to evaluate the
subsurface conditions along the project alignments.
Landau has tentatively scheduled drilling for May 18 through 19, 2022. Drilling will occur between
approximately 8:00 a.m. and 5:00 p.m. Google Earth figures are attached which show the approximate
work locations. The actual locations of the borings may vary somewhat as their final positions will be
determined based on underground utility checks, which will be conducted prior to drilling.
A truck- or track -mounted drill rig equipped with hollow -stem auger will occupy each of the work
locations for approximately 2 to 3 hours. State licensed traffic control flaggers, along with appropriate
traffic control devices will be provided when the drilling activities impact traffic. Traffic control
devices will include standard "Road Work Ahead," "Left Lane Closed Ahead", "Be Prepared to Stop"
signage, traffic channelization cones, and other traffic control devices, as appropriate. The borings will
be located in the paved roadway area or in the adjacent parking strip. See the attached traffic control
plans for details.
Monitoring wells are planned to be constructed at each of the boring locations. Monitoring wells will
be constructed per the attached typical monitoring well construction detail.
Hard surficial materials (i.e., asphalt or concrete) will be cut with a 12-inch diameter coring machine
to allow for drill cuttings to exit the approximately 6-inch diameter boring while minimizing potential
damage to surrounding pavement. In locations where monitoring wells are installed, a flush mounted
steel monument set in concrete will be installed as shown in the attached typical monitoring well
detail. Excess soils will be hauled away and properly disposed of offsite. While Landau cannot
precisely determine boring locations at the time of ROW application, Landau will make every effort to
avoid locating borings in the traffic wheel paths.
Landau will have an emergency spill kit available during the drilling activities in the unlikely event of a
petroleum leak or spill.
155 NE 10011 St, Ste 302 • Seattle, Washington 98125 • (206) 631-8680 • www.landauinc.com
City of Edmonds Phase 10 Sewer Replacement Project
Landau Associates
Landau looks forward to working with you and your designated staff during this and later phases of
the project. If you have any questions, please contact either Tyler Cartwright (425-329-0258) or Steve
Wright (425-329-0290).
LANDAU ASSOCIATES, INC.
Tyler Cartwright
Staff Geotechnical EIT
TGC/SMG
Attachments: Proposed Boring Locations
Right -of -Way Construction Permit Application
Typical Monitoring Well Detail
Traffic Control Plans
Evidence of Insurance
April 28, 2022
MONITORING WELL
1.5 ft o Flush Monument embedded
in concrete seal
8.5 ft I fA JA Bentonite chips (hydrated)
1 ft+ 2-inch diameter, Schedule 40,
PVC well casing
9.5 ft 4-inch diameter, Schedule 40,
PVC screen (0.020-inch slot
size)
6 in Threaded end cap
2 ft - 2/12 sand pack
Notes:
Typical Monitoring Well Construction Figure
LANDAU Design /-