Loading...
COMPACTION REPORT - STM MH 4.26.2022FIELD DENSITY TEST REPORT Wrerracon Report Number: 81225029.0005 Service Date: 04/26/22 21905 64th Ave W, Ste 100 Report Date: 04/26/22 Mountlake Terrace, WA 98043-2251 Task: Field Density Testing 425-771-3304 Client Project - 81225029 CA Ventures LLC Anthology of Edmonds Attn: Michael Duggan 21200 72nd Ave. W. 130 E Randolph St Ste 2100 Edmonds, WA Chicago, IL 60601-6223 Material Information Mat. No. 1 Proctor Ref. No. Classification and Description 81225029.0003A 1-1/4" base course Field Test Data Test No. Test Location Permit No.: BLD2021-0088 Laboratory Test Method ASTM D1557 Lab Test Data Project Requirements Optimum Water Max. Lab Water Content Density Content Compaction (%) (pcf) (%) (%) 5.0 140.1 Min 95 Probe Wet Water Water Dry Percent Lift / Mat. Depth Density Content Content Density Compaction Elev. No. (in) (pcf) (pcf) (%) (pcf) (%) Stormwater Pipeling Trench Backfill 1 Catch basin east side of site -1 1 8 140.1 7.2 5.4 132.9 95 2 Catch basin east side of site FG 1 8 142.6 7.7 5.7 134.9 96 Datum: Pavement S/N: 31185 Make: Troxler Model: 3440 Last Cal. Date: 07/16/2021 Comments: Test and/or retest results on this report meet project requirements as noted above. Services: Perform in -place density and moisture content tests to determine degree of compa ;tion and material moisture condition. Terracon Rep.: Kyle Bennett Reported To: Catalyst Construction Contractor: Report Distribution: See attached distribution list. Reviewed By: _ Ut Jarom dray Project Manager Test Methods: ASTM D 6938 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cRoo07, 11-16-12, Rev.7 Page 1 of 1 FIELD DENSITY TESTING REPORT rerracon Report Number: 81225029.0005 Service Date: 04/26/22 21905 64th Ave W, Ste 100 Report Date: 04/26/22 Mountlake Terrace, WA 98043-2251 Task: Field Density Testing 425-771-3304 Client Project CA Ventures LLC Anthology of Edmonds Attn: Michael Duggan 21200 72nd Ave. W. 130 E Randolph St Ste 2100 Edmonds, WA Chicago, IL 60601-6223 Project Number: 81225029 Permit Number: BLD2021-0088 Time Onsite: 1020 - 1040 Attachments: Field Densitv Test Report A Terracon representative visited the site at the request of Catalyst Construction Group to perform field density test. Santana performed the earthwork activities. Field Density Tests At the time of our arrival we noted the material used as fill for the stormwater pipeline trench backfill was 1 1/4-inch crushed rock. Material was observed to be adequately moisture conditioned and was placed in lifts approximately 12-inches thick. The fill placed was observed to be firm and stable during the application of compaction efforts. Field density tests were performed utilizing nuclear method (ASTM D 6938). The test results met the minimum specified compaction requirement of 95%. Refer to the attached Field Density Test report for individual test data. Services: Perform in -place density and moisture content tests to determine degree of compaction and material moisture condition. Terracon Rep.: Kyle Bennett Reported To: Catalyst Construction Contractor: Report Distribution: See attached distribution list. Reviewed By: JUr Jarom Gray Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. AF000s, 3-7-12, Rev.s Page t of t Distribution Page Report Number: 81225029.0005 Ferracon Service Date: 04/26/22 21905 64th Ave W, Ste 100 Report Date: 04/26/22 Mountlake Terrace, WA 98043-2251 Task: Field Density Testing 425-771-3304 Distribution List (1) CA Ventures LLC, Michael Duggan (1) 801 Riverfront Property Owner LLC, Mike Roggeman (1) Catalyst Construction Group, Alex Kushner (1) Catalyst Construction Group, Alex Lebowitz (1) Catalyst Construction Group, Art Mitchell (1) Catalyst Construction Group, Eileen Mortenson (1) Catalyst Construction Group, Zach Ryan (1) City of Edmonds WA, Eric Carter (1) Malcolm Drilling Co Inc, Adam Running (1) Malcolm Drilling Co Inc, Brian Courts