Loading...
APPROVCED CALSNATIONAL CERTIFIED TESTING LABORATORIES 3310 HILLAVENUE - EVERETT, WASHINGTON 98201 - TELEPHONE (428) 25"799 FAX (425) 259-4938 www.ncU!nc.com NFRC SIMULATION REPORT NCTL310-3931 Sono REPORT TO: GLOBAL SOLARIUM 910 W. 11 TH ST. SUITE#A VANCOUVER, WA 98660 SIMULATION NUMBER: SIMULATION DATE: SIMULATION REVISION DATE: ADDENDUM SIMULATION DATE: NCTL310-3931 02/12/2014 N/A N/A PRODUCT: ALUMINUM CLASSIC SOLARIUM ROOF Report is being generated for a new product. Professionals in the Science of Testing EU)-zCW-o015 310-3931 C DD �6i Page 1 of17 ►� RECEIVED COPY BUILDING EOAO SIMULATION METHOD: NFRC 100, Procedure for Determining Fenestration Product U-Factors (2010) NFRC 200, Procedure for Determining Fenestration Product Solar Heat Gain Coefficients at Normal Incidence (2010) NFRC 500, Procedure for Determining Fenestration Product Condensation Resistance Values (2010) Technical Interpretation Manual (2010) SIMULATION PROGRAMS: Center of Glass: Window 6.3.74 2-D Heat Transfer: THERM 6.3.46 Total Product Calculations: Window 6.3.74 MODEL/TYPE: CLASSIC ALUMINUM LINE SOLARIUM ROOF (SKSL) VALIDATION MATRIX: NONE CONFIGURATION: 00 SIMULATION SIZE: 2000mm x 2000mm (79" x 79") NAIL FIN: NONE FRAME TYPE AND FINISH: Painted aluminum SASH TYPE AND FINISH: N/A THERMAL BREAK: TYPE: Urethane SIZE: 4.76mm FRAME OPTIONS: NONE REINFORCEMENT: NONE OAVA: NONE IG GLASS PARAMETERS: Glass IG unit overall dimension remains constant at a nominal 1 "; the gap varies with glass thickness. GLAZING METHOD: Glazing set on setting block against glazing tape on interior and exterior on the horizontal sections and neoprene gaskets on the vertical sections and held in place by rib cap and bolt. GAS FILL METHOD: Evacuated chamber GAS FILL CONCENTRATION: 90% Argon (PROVIDED BY THE MANUFACTURER) SPACERS: SS-D: Stainless Steel with PIB/silicone sealants. GRILLS (INTERNAL OR TDL): NONE GRILLS (PATTERNS): For U-Factor, SHGC and VT calculations standard default grid pattern established by Window 6 which is assumed to be closest to but not greater than 12" OC is used. 310 3931 Page 2 of17 EOAO WEATHERSTRIP: NONE CONTINUOUS HARDWARE: NONE THERMAL BRIDGING: Stainless steel bolt. ELECTRONIC DATA: Supporting information including THERM 6 and WINDOW 6 files are being submitted as part of this report. The simulation matrix is being submitted electronically. ADDITIONAL INFORMATION: The manufacturer is capable of producing, in its normal manufacturing process, products in sizes identical to the model sizes listed in the NFRC 100 Table 4-3 and have a least deviation of 0 within the tolerances of NFRC 100. All simulations are performed in the sizes and configurations listed in NFRC 100 Table 4-3 except that a non-standard size may be simulated and identified in the matrix to match the manufacturer's physical test sample. Glass and glazing types, Low-E placement, finishes and other required information is included in the NFRC U-Factor Simulation Summary Report and/or the NFRC SHGCNT Simulation Summary Report included in this document. Additional supporting information and modeling assumptions are included in the individual reports obtained from the approved simulation programs and in the notes following the required summary reports. NOTES: 1) All simulations use the emissivity from the NFRC approved files in IGDB Version 33.0. 2) The following simplifications to a Product Line per NFRC 100 were applied: A) For U-Factor purposes, all glazing options which vary only in glazing tint or obscurity are assumed to have the same U-Factor as glazing options without such tints or obscurity and are not simulated, provided that such options are not associated with a change in coating properties. 3) A default frame absorptance of 0.500 is assumed. 4) For Solar Heat Gain and Visible Light Transmittance; all frame, divider and glass options are grouped using the best case center of glass/worst case frame values from the "U" Factor calculations as required by NFRC 200- 2010. 310 3931 Page 3 of17 EOAO CONCLUSIONS Detailed assembly drawings, cross -sectional drawings, and a bill of materials as supplied by the client were used as the basis for performing the simulations. Copies are attached to this report. The results were secured by using the designated methods and NFRC approved simulation programs as required by, and in full compliance with NFRC procedures. This report does not constitute certification of this product. The results in this report apply to the sample as shown in the attached drawings, using the components and construction methods described herein. NCTL-NW does not warrant the accuracy of the computer programs used to obtain the results. This report is the joint property of NCTL-NW and the client to whom it is issued. Permission to reproduce this report by anyone other than NCTL-NW and the Client must be granted in writing by both of the above parties. This report may not be reproduced except in its entirety. Ratings values included in this report are for submittals to an NFRC-licensed IA are not meant to be used directly for labeling purposes. Only those values identified on a valid Certification Authorization Report (CAR) by an NFRC accredited Inspection Agency (IA) are to be used for labeling purposes. The Condensation Resistance results obtained from this procedure are for controlled laboratory conditions and do not include the effects of air movement through the specimen, solar radiation and the thermal bridging that may occur due to the specific design and construction of the fenestration system opening. Units and rounding is in accordance with NFRC 601, Units and Measurement Policy except that all units may be reported in IP as the primary units after conversion and any matrix is reported in IP units only unless requested otherwise by the client. Daniel E. Sowell Project Reviewer ` t d,tA,�, a. c4/4 g ` Martha A. Hughes NFRC Certified Simulation Technician Simulator in Responsible Charge 310 3931 Page 4 of17 EOAO KEFF NCTL FILE 310-3931 EOAO BOLT SPACING (mm) = 228.6 BOLT HEAD WIDTH (mm)= 9.407 BOLT MATERIAL ST STEEL SECTION 1 2 3 4 5 6 Kn Kb Wb = Sb = Fb = Fn = Keff = MATERIAL AIR ALUMINUM AIR cellular PVC air ALUMINUM TOTAL 0.063269 17 CONDUCTIVITY DEPTH(mm) R (m2K/w) 0.024 3.4368 0.1432 160 1.3579 8.4869E-06 0.024 3.1581 0.1315875 0.067 27.9383 0.41698955 0.024 2.5141 0.10475417 160 11.996 7.4975E-05 ST STEEL Dt Rt 0.0504012 0.79661468 9.407 BOLT HEAD WIDTH(mm) 228.6 BOLT SPACING (mm) FB % 0.041150 4.115048119 0.958850 0.760 W/m-K 310 3931 Page 5 of17 EOAO APPENDIX A NFRC SIMULATION REPORT MATRIX 310 3931 Page 6 of17 EOAO VT GRID >=1" VT GRID<1" VT NO GRID 0 U' 1- iA 0 0 SHGC GRID>=1" SHGC GRID<1" SHGC NO GRID M LO C\! 0 0 Condensation Resistance 0 U-factor r` co 0 0 Grid Size Grid Type ZI z 0 0 Spacer U) Ch Tint CC 0 U Emissivity Surface 4 Emissivity Surface 3 N 0 0 Emissivity Surface 2 N 0 0 Emissivity Surface 1 % of Gap Fill 1 rn rn 0 0 Gap Fill 1 Q Q Gap 1 c CD r- 0 0 r- 0 Pane Thickness #2 0 10 0 °r° Pane Thickness #1 r 0 0 co co co � J Pane ID #2 U E E co E co z � M Pane ID #1 ¢ U M LE Product Number N (n o PRODUCT 0 0 O O z z 310 3931 Page 7 of17 EOAO REVISION SUMMARY Revision No. Date Page No. Description EOAO 02/12/2014 Original Report 310 3931 Page 8 of17 EOAO