Loading...
ENG2021-0351 ROW PERMITOF WAY EUC PERMIT PERMITNUMBER, City of Edmonds EdmondsRIGHT 98020 1 1 www.cityofedmonds.gov Description: PUD-REPLACE 11 BAD ORDER POLES ISSUED: 05/26/2022 Address: 18809 SOUND VIEW PL EDMONDS WA 98020-2358 EXPIRES: 11/26/2022 Permit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 27031300401100 NAME TYPE NAME ADDRESS PHONE APPLICANT SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216 CONTRACTOR SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216 OWNER RONDEAU RICHARD & SHELLEY UNKNOWN, UNKNOWN WA FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $0.00 ENGINEERING INSPECTION FEE $220.00 $0.00 RIGHT OF WAY STANDARD - EUC PERMIT FEE $330.00 $0.00 • REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW 05/26/2022 :»•>/F9:1H ]1 DATE Printed: Thursday, May 26, 2022 8:45:07 AM 1 of 2 -KRWOF WAY EUC PERMIT City of Edmonds •:• •ENG2021-0351 www.cityofedmonds. ov/425.771.0220 CONDITIONS CONDITION TYPE ALERT RESIDENTS ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD ESC REQUIREMENTS REQUIREMENTS. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the HOLD HARMLESS issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT. INSPECTIONS www.mybuildingpermit.com POTHOLING VERIFY CLEAR BORE CROSSINGS. RESTORE LANDSCAPE Restore landscape to like or better conditions Sound or noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND AND NOISE weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites and activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION TYPE DATE RESULT COMPLETE A-1 JOB START X-2 ENGINEERING FINAL** E-7 TRAFFIC CTRL Printed: Thursday, May 26, 2022 8:45:07 AM 2 of 2 ENG2021-0351 of EDMOtios RECEIVED RIGHT OF WAY CONSTRUCTION PERMIT APPLICATION AUG 19 2021 Complete and submit this Application in accordance with the Submittal CITY OF EDMONDS i?ao Requirements outlined in Right -of -Way permit Handout E6�. DEVELOPMENT SERVICES DEPARTMENT If any field is not applicable to your project, write "N/A" instead of leaving biaiiK. All fields required. Incomplete Applications will be denied. SECTION A General Info Project Name Replace Depreciated poles in City of Edmonds Site Address or if no site address use Property Address at NW corner of project area: Various Locations Associated Permits: BLD PLN ENG Owner and Entity Holding Franchise (if applicable) Name of Company Snohomish County PUD # 1 Franchise Ordinance No: Point of Contact Andrea Nelson Title Lead Designer Address P.O. Box 1107 city Everett State WA zip 982o6 Phone 425-512-3526 Email ajnelson@snopud.com Contractor and Authorized Agent of Owner Name of Company (see note below) Contractor Contacts During Construction Primary Name Agent Name Title Title Mobile Address Email City State Zip Secondary Name Phone Title Email Mobile City of Edmonds Business License No: Email State License No: 313-005-741 a Contractor verifies it is currently bonded Ey Contractor verifies it currently has general liability insurance NOTE: ECDC18.6o.o2o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. ❑ Multifamily residential ❑ Commercial ❑ City project ❑ Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as welt ❑ Traffic Control Only (no associated development) iNUtility Franchise Work (no associated development) City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021 Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) Replace (11) Depreciated poles in City of Edmonds. WO# 100002o63, sheet 1 Tree Trimming needed in various spots Communications on poles are Comcast and Ziply RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF I x LF SF Alley 72 hours + LF Ix I LF SF Parking 72 hours + LF Ix I LF SF SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C. 1. The work in the right of way is on or for the following type of facilities: ❑ telecommunications ❑ cable iN power ❑ gas ❑ water ❑ sewer ❑ storm Details of Work to be Completed 1. Does the utility owner have existing overhead infrastructure in the area of work? Yes x No 2. Will any equipment be added underground or above ground (e.. pedestals, vaults, etc.)? X If yes, describe: 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? X 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility stem? X 5. Does the work involve proposed additions to an aboveground utility stem? If es: x Are the additions for the purpose of serving new commercial development? Are the additions for the purpose of serving a single-family residential subdivision? Details of Work to be Completed Yes No 6. Does your project involve rebuilding or replacing utility equipment which currently serves more than one lot or commercial development? If yes, answer the following questions related to project area, i.e. the actual area in which the X project is proposed: 6a. Does your project involve wires/cables/lines? If yes: X How many are existing? I I How many are to be added? NONE City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 6b. Does your project involve poles? If yes: X How many poles are existing in the project area? 11 What is the height of the existing poles? 45 How many poles are to be removed? 11 Are additional poles to be laced? X How many? I I What is the height of the additionalpoles? 6c. Are any poles to be modified/rebuilt/replaced? If yes: X How many? 1 11 1 What is the height of the poles after? same Describe the modification rebuild: replace existing SECTION C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsible for all permit fees. APPLICANT SIGNATURE: Andrea Nelson DATE: 8/18/2021 APPLICANT PRINTED NAME: Andrea Nelson APPLICANT TITLE: Lead Designer NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM scB O E, NTS 37 CKT CONSTRUCTION NOTES" FU654�' 12-345 O PLI# 134 SET 35 CL2 POLE 1'W AS STAKED, SET 7'DEEP (PW2035) INSTL (U 12' SNGL HLX AHR E,L=5'(AO102) INSTL (ll 3/8' DG IN PRI POS TO AHR (GO113) INSTL NEUT- SERV INSUL (]0102) CNCT 145'OF EX SEC TO NEW POLE ©AT REDUCED TENSION XFR (2) OH SEC SRVCS STRIP, TOP,& ENFORCE POLE ATTACHMENT AGREEMENT © PLI# 133 SET 45' CL1 POLE 2' N & 4'E, SET 9' DEEP (PW1050) (AGAINST FENCE) INSTL (D 12' SNGL HLX AHR NW, L=15'AS STAKED (AO102) INSTL (ll 3/8" DG ]N PRI POS TO AHR (GO113) INSTL POLE KEY- EAST (PFO100) FRAME ASSY (12V109) 1 PHASE VERT DE RMV 75KVA OH XFMR DIST# 75-1902 SER# HANG 37KVA OH XFMR & 15A FU (12V601, BA21P, E0115) DIST# SER# VOLT ----- /----- /-____ INSTL NEW 4'ARM (10501) XFR ST LT HEAD SL-130600-A XFR (4) OH SEC SRVC INSTL 2" PRI RISER ASSY & 40A FU (12U111, E0140) -SEE BO CABLE UG# 4096 WO# 10007633-0060 STRIP, TOP,& ENFORCE POLE ATTACHMENT AGREEMENT © PLI# 129 ALREADY BEEN DONE UG UG WIRE REMOVAL NOTES Fuss FU25 OPLI# 205 SET 50' CL1 POLE 7' EAST, SET 7' DEEP (PW1050)-10' OFF TRAVEL FROM PLI-133 TO PLI-120 LANE 75 FRAME ASSY (12F304) 3 PHASE DBL ARM ANGLE REMOVE (1) #6 CU IF-650' 37 4- FRAME ASSY (12V115) 1 PHASE END OF ARM -WEST INSTL (U 12" SGL HLX AHR E,L=5'(A0102) INSTL SIDE WALK DG IN PRI POS TO AHR (GO107) RMV50KVA ON CKT 25 J~� DIST# 50-1918 - PUD TO ENFORCE POLE ATTACHMENT MPL 12 ZP SER# AGREEMENT. 15 0 25 HANG NEW 25KVA ON XFMR & 8A FU (12F601,BA21N,E0108) - PUD IS RESPONSIBLE FOR ENSURING THAT THE DG DIST# DG FU25 OLD POLES ARE REMOVED. _- SER# VOLT REPL 6'ST LT ARM (L0502) XFR ST LT HEAD #SL-113070-A INSTL 3" SEC RISER ASSY OU707) SET LRG RED (VO102) AT E BASE OF POLE W/ (3) 5-POS TERM BARS (T1522) RUN 40'OF 350KCM POLE TO RED (C1204) RECONNECT EX SEC SRVCS STRIP, TOP.& ENFORCE POLE ATTACHMENT AGREEMENT OPLI# 211 SET 45'CL2 POLE- 3' NE, SET 7' DEEP (PW2045)-10'FROM HYDRANT & LANE INSTL (D 12" SGL HLX AHR E,L=5'(A0102) INSTL (ll 3/8' S/W GUY IN PR[ POS TO AHR (GO107) FRAME ASSY (12F313)3 PHASE TANGENT W/ END OF ARM TAP XFR 25KVA OH XFMR (12V601) DIST# 25-12215 SER# INSTL 2" PR[ RISER ASSY & 15A FU (12U111, E1015) PLUMB 2" RISER INTO EX PRI CONDUIT -SEE BO CABLE UG# 5795 WO# 100002063-0060 INSTL (D 3" SEC RISER ASSY NU705) SET SM PED (VO10D AT BASE OF POLE W/ (3) 4-POS TERM BARS (T1521) OPLI# 132 RUN 35' 350KCM POLE TO PED (C1204) REFRAME POLE USING ASSY (12V101) 1 PHASE VERT TANGENT REPL 10' ST LT ARM (LO504) RMV EX CROSSARM ASSY XRF ST LT HEAD #SL-130131-A REPLACE CO (E0202) XFR (1) OH & (1) UG SEC SRVC STRIP, TOP,& ENFORCE POLE ATTACHMENT AGREEMENT OPLI# 128 REFRAME POLE USING ASSY (12V113) 1 PHASE VERT TANG LATERAL SLACK SPAN LATERAL RMV EX CROSSARM ASSY OK PLI# 208 REPLACE CO (E0202) SET 35'POLE 6'W AS STAKED, SET 6'DEEP INSTL NEUT-SVCE INSUL (I0102) OPLI# 127 XFR EX OH SEC SRVC REFRAME POLE USING ASSY (12V101) 1 PHASE VERT TANGENT STRIP, TOP, & ENFORCE POLE ATTACHMENT AGREEMENT RMV EX CROSSARM ASSY REPLACE CO (E0202) REPL 8'ARM AND SL-2474-D W/ LED A-11(L0503, L0210) © PLI# 126 SET 45'CL2 POLE 1' NE AS STAKED, SET 7' DEEP (SW2045) FRAME ASSY (12V101) 1 PHASE VERT TANGENT RMV 25KVA ON XFMR DIST# 25-26036 SER# HANG NEW 15KVA ON XFMR & 6A FU (12V601, BA21L, E0106) DIST # SER# OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING VOLT ----- /----- /----- ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY INSTL UMB 2"PR SER INTO 2°40ONDUIT12U111, E0140) UTILITIES MAY REQUIRE A SEPERATE PERMIT. -SEE BO CABLE UG# 2511 WO# 100076336 STRIP, TOP,& ENFORCE POLE ATTACHMENT AGREEMENT OPLI# 122 REFRAME POLE USING ASSY (12V113) 1 PHASE VERT TANG LATERAL RMV 25KVA OH XFMR DIST# 25-11411 SER# HANG NEW 15KVA OH XFMR & 6A FU (12V601, BA21L, E0106) DIST# SER# VOLT ----- /----- /----- OWNER/CONTRACTOR IS RESPONSIBLE FOR REEL 8'ARM (10503) EROSION CONTROL AND DRAINAGE XFR ST LT HEAD #SL-130633-A RMV EX CROSSARM ASSY R E S U B Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. 25 15 (U #4 CU SOLID PRI & (U #4 CU SOLID NEUT AFTER, NTS UG jSFU25 37 37 ON 25 Q_ MPL 12-345 15 25 UG 1125 UG J�o �O 25 15 37 25 FU15 5 W 37 FU40 U 25_ FU15 D_ J O FU15 FU25 5 25 (2) #6 CU SOLID, (1) #2 ACSR (PH2) PRI & (1) 46 CU SOLID 1 2 3 CKT MPL FU65 25 12-345 25 FU15 15 W 7 FU40 U 25 FU15 CL T O FU15 FU25 15 (U #4 CU SOLID PR] & (2) #6 CU SOLID, (1) #4 CU SOLID NEUT (U #2 ACSR (PH2) PR] & (1) #6 CU SOLID NEUT 1 2 3 on WO 100002063 - TASK 0030 SCALE 1" = 100' DFTR CHKR E ENGR MARK BABB w APVD DATE 5/5/21 126 / - - - - FUOO `18921 0 ENGINEERING DIVISION Ma 12 2022 y / /� 26-2s63s i 19095 P BLAKE 2P11 ' E19°79 19611 o .E APPROVED AS NOTED � PL CITY OF EDMONDS H � 0122 9656 9648 O DEVELOPMENT SERVICES 19013 9615 19012 4108 AA ,, II,, 11Qll WQ✓;tdj..nn? 05/25/2022 VV DEPARTMENT 12 � SL-130633--A s45 �tiotie� K 208 • 3 ^f ^^ ^ 1 OF 3 �i Pun LAYOUT LEGEND: V AU L T CABLE ALL FOOTAGES APPROXIMATE PAD MOUNTED TRANSFORMER BY PUD OR PUD'S CONTRACTOR FROM POLE TO A-48614 ® so' OF (1) 1/0 AL 15KV CNCTRC NEUT JCKTD PRI IN EXST 2" PVC SUBMERSIBLE TRANSFORMER A- 4 8 6 14 MAKE PO REEL J ABOVE GROUND J-BOX 42" x 42" x 30" CONCRETE OPEN BOTTOM W/A 11" x 25" ACCESS HOLE FROM A-48614 TO A-8814 0 SUBMERSIBLE J-BOX 285' OF (1) 1/0 AL 15KV CNCTRC NEUT JCKTD PRI IN EXST 2" PVC Q SECONDARY VAULT MAKE PO REEL ❑ PULLING VAULT CONSTRUCTION NOTES: FROM A-48614 TO A-13710 O AT POLE 240' OF (1) 1/0 AL 15KV CNCTRC NEUT JCKTD PRI IN EXST 2" PVC SWITCH CABINET MAKE PO REEL NEW POLE SET ON TASK# 03. © SMALL SECONDARY PEDESTAL AT VAULT A-48614 TOTAL FOOTAGE OF 1/0 CABLE INSTALLED: 585' © LARGE SECONDARY PEDESTAL INSTALL J-BOX CABINET (12U151). SL STREET LIGHT PEDESTAL NSTALL (3)1/0 200 AMP LB ELBOWS (T1105). INSTALL 1) INSTALL CABLE AMR TAGS PER CAP SCHEMATIC. DUCT PRIMARY UNDERGROUND CABLE DIRECTIONAL BORE BY PUD'S CONTRACTOR -------�—�- #350 SECONDARY UNDERGROUND CABLE AT VAULT A-8814 - - - - - - - - 4/0 SECONDARY UNDERGROUND CABLE REMOVE EXISTING 75 KVA PDMT TRANSFORMER. OA 36' OF (1) Y'HDPE 1/0 SECONDARY UNDERGROUND CABLE DIST S- -X TOTAL FOOTAGE OF 2" HDPE INSTALLED: 36' --—--STREET LIGHT CABLE SER SERVICE CONDUIT MAKE CABLE NOTES o POLE AND OVERHEAD LINE REMOVE LILY PAD. FROM POLE TO A-8814,ABANDON PRIMARY UGND CABLE# 14680. PROPERTY LINE INSTALL CONCRETE OPEN BOTTOM VAULT 42"x42" FROM POLE TO A-13710, REMOVE PRIMARY UGND CABLE# 50072 x3O" W/A 21" x 25" ACCESS HOLE (VO301A). — RIGHT-OF-WAY LINE SET NEW 37.5 KVA 240/120V PDMT TRANSFORMER. TOTAL FOOTAGE: 555' U EXISTING UNDERGROUND CABLE OTC EXISTING DUCT SER — FUTURE DUCT MAKE ------- S------ SANITARY SEWER/MANHOLE ------- D -----fl STORM DRAIN/CATCH BASIN INSTALL (1) 200 AMP LB ELBOW (T1105). INSTALL CABLE TAGS PER SCHEMATIC. ------- W ------ WATER MAIN/METER AT VAULT A-13710 Y FIRE HYDRANT REMOVE EXISTING 25 KVA PDMT TRANSFORMER. + STREET LIGHT * UNDERGROUND LOCATOR MARKER DIST N- -X SER SCHEMATIC: MAKE SET NEW 25 KVA 240/120V PDMT TRANSFORMER. REFER TO SHEET S1 OTC VAULT INSPECTION FORM: SFR MAKE REFER TO SHEET 3 INSTALL (1) 200 AMP LB ELBOW (T1105). / NSTALL CABLE TAGS PER SCHEMATIC. RIGHT OF WAY AND PUD EASEMENT: THE FOLLOWING APPLIES TO SOUND VIEW PLACE ` R.O.W. = 50 FEET \ \ PUD EASEMENT = 10 FEET 18732 \ 18726 � A 8814 EXISTING L \\___— P ' 18803 - EXISTING176 OF �� 2" PVC \ � O o `EXISTING / 2OF ` 2"" PVC 18805 / \ A-13710 \,� / ABANDON 36' EXISTING sFCTION OF *j A-48614 CABLE# 14680 S-1902-X i / NEPO /SEW ON LE TASK* 03 LAYOUT / V= 41' LOCATION 18732 SOUND VIEW PLACE,EDMONDS 98020 AREA LYNNWOOD POLE NO SEWS 13 T 27 R 3 DATE 1/12/15 ORDER 100076334 REASON FOR WORK REPLACE BO CABLE FOR ENGINEER S. HUNT OPERATION 0060 ROBERTSON DRAFTER McPHERSON UGND No 4096-2 APPROVED ALSF SCALE NOTED DATE WORK COMPLETED FOREMAN DATE 3/2/21 INSPECTOR SUBSTATION MAPLEWOOD CIRCUIT NO 12-345 PHASE 1 DATE FEES REQ'D ❑ res ■ No ROAD CROSSINGS ONLY PRIMARY OVERHEAD ❑ RESIDENTIAL ❑ COMMERCIAL APPV DATE DESCRIPTION LED REVISIONS .S =$ APPV NO. DATE DESCRIPTION PRIMARY UNDERGROUND ❑ RESIDENTIAL PAS 1 5/21 REV CONSTRUCTION NOTES AT A-8814 AND A-13710 ❑ COMMERCIAL BASIC FEE S LEU• SECONDARY UNDERGROUND BASIC FEES S IAS—BUILT I WORK IN RIGHT OF WAY ❑ PRIMARY ❑ SECONDARY FT mS 3 MISCELLANEOUS FEES VAULT S— PERMIT S s— s S TOTAL DUES_ DATE PAID RECEIPT• ENGINEER SPENCER HUNT CUSTOM PHONE (425) 783-4370 PHONE PAGER/ DISTRICT PROJECT LEADER: ANDREA NELSON (425) 512-3526 N NORTH RESUB May 12 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PI UGrl SOUND WORK SITE VICINITY MAP PERMITS (DATE GRANTED) ■ TREE TRIM ❑ STATE ❑ COUNTY ■ EDMONDS EASEMENTS ❑ REQUIRED E ■ NOT REQUIRED REQUEST NO. DATE APPROVED FOREIGN CONTACTS ❑ JPN- ❑ JOINT TRENCH FRONTIER & CATV ❑ JOINT BORE FRONTIER & CATV POLE STENCILING FROM TO TAKE OFF POLE PRE-CONSTR REQUIREMENTS ■ TREE TRIM ❑ PUD LOCATOR ❑ BACKHOE ❑ ■ ONE CALL DATE STREET LIGHTING ❑ YES ❑ NO READY I IIPHASING GIS I IWORKING 1 LINE I IFINISHED POLE/ OINT USE LOCATION MAP PAGE 454, G3 PRINTED C TAGS ZD o� VAULT: A-48614 CABLE: 90234 THRU 90236 oa 0) � 40 SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM LANE CLOSURE ON A TWO—LANE LOW —VOLUME ROAD (ONE FLAGGER OPERATION) W20-1 'X IxEIO I u W20-4 aow u[1p W20-7A ■� ` SPEED Lei SPACINGGNBUFFER A. B.0 IF T) (FT) 25 200 55 30 200 85 35 350 120 40 350 170 45 500 220 50 500 280 55 500 335 FA F20-4 LANE CLOSURE ON A TWO—LANE ROAD (TWO FLAGGER OPERATION) W20-1 m u.m T u W20-A .EW m W20-7A • nao C20-2 =(OPTIONAL) gL Op� ° IW lW cr H t/1 O O <E_C20-2A .o10imc L (OPTIONAL) nu�? �E*A. � SPACING NG B.0 IF 13 BUFFER (FT) 25 200 55 30 200 85 35 350 120 /0 350 170 45 500 220 50 500 280 55 1 500 1 335 ac EME w W20-. TRAFFIC CONTROL INSPECTION SHALL BE SCHEDULED EVERY TIME THE WORK ZONE IS SET UP. WO 100002053 TASK 03 $ SCALE NTS DFTR LEGEND, CHKR O CHANNELIZING DEVICE r FLAGGING STATION ENGR A. NELSON e PORTABLE SIGN AND SUPPORT RECEIVED APVD ®® WORK VEHICLE WITH FLASHING LIGHT ENGINEERING DIVISION DATE 2/12/21 ®® TRUCK-MOUN TRUCK -MOUNTED OR ATT NUATOR (TMA)HICLE WITH A U G 19 2021 APPROVED AS NOTED _ WORK AREA ,l�� i,�Q✓.XFa.nnp 05/25/2022 TRAFFIC a O WARNING SIGN CITY OF EDMONDSvv C�ITRvL DEVELOPMENT 5 SERVICES DEPARTMENT 1 HIGH LEVEL WARNING DEVICE TCP