FIR2022-0057_Fire_Sprinkler_Equipment_Specification_Sheets_5.26.2022_9.45.05_AM_2895017
FireLock° V27, K5.6 Models V2709,V2710 Standard Spray Horizontal and Recessed Horizontal Sidewall Standard and Quick Response d- - now,/ L /� V2709/V2710 V2709/V2710 Standard Horizontal Recessed Horizontal Sidewall Sidewall Approvals/Listings: c usreu us FM LPCB See Victaulic Publication 10.01 for more details. Product Description: These Model V27, standard spray horizontal sidewall sprinklers are designed for up to ordinary Hazard per NFPA 13, and can be used for standard or recessed installations. The design provides a crescent -shaped water discharge pattern for installation along a wall or under a beam or ceiling. It is cast with a hex -shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides up to 3/411/19 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. Job/Owner System No Location Contractor Submitted By Date ✓ctaulia® 40.11 Technical Specifications: Models: V2709, V2710 Style: Horizontal Sidewall or Recessed Horizontal Sidewall Nominal Orifice Size: 1/2713 mm K Factor: 5.6 Imp./8.1 S.I.1 Nominal Thread Size: 1/2715 mm Max. Working Pressure: • 175 psi/1200 kPa (FM) • 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Min. Operating Pressure: • 7 psi/48 kPa Temperature Rating: See chart on page 3 1 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Engineer Spec Section Paragraph Approved Date Exaggerated for clarity victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.11 40.11 2545 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. 1 �ctauI c' victaulic.com I Sprinklers I Fire Lock® I K5.6, V27 I Publication 40.11 Material Specifications: Accessories Horizontal Deflector: Commercial bronze per UNS C22O00 Bulb: Glass with glycerin solution Bulb Nominal Diameter: ❑ Standard: 5.0 mm ❑ Quick Response: 3.0 mm Load Screw: Low Silicon bronze per UNS C65100 Pip Cap: Low Silicon bronze per UNS C651OO Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S3O2OO Installation Wrench: ❑ Open End: V27 ❑ Recessed: V27-2 Sprinkler Finishes: ❑ Plain Brass ❑ Chrome plated ❑ White painted3 ❑ Flat black painted3 ❑ Custom painted3 ❑ Proprietary Nickel/Teflon2 coating3 ❑ VC-2504 155, 200, 286 SR Only: ❑ Wax3 For cabinets and other accessories refer to separate sheet. NOTE: Weather resistant recessed escutcheon available upon request. 2 Teflon is a registered trademark of Dupont Co. 3 UL Listed for corrosion resistance. 4 UL Listed and FM Approved for corrosion resistance. 40.11 2545 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 2 ictauliic' victaulic.com I Sprinklers I Fire Lock® I K5.6, V27 I Publication 40.11 Approvals/Listings: Model APPROVALS/LISTINGS V2709 V2709 Recessed V2710 V2710 Recessed V2710 Recessed Orifice Size (inches) 1/2" 1/2" 1/2" 1/2" 1/2" Orifice Size (mm) 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.I s 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Quick Quick Quick Recessed Recessed Recessed Deflector Type Horizontal Horizontal Horizontal Horizontal Horizontal Sidewall Sidewall* Sidewall Sidewall (up to Sidewall (up to 1/2" adjustment) 3/4" adjustment) Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 155°F/68°C 135°F/57°C 155°F/68°C 135°F/57°C 135°F/57°C cULus 175°F/79°C 155°F/68°C 175°F/79°C 155°F/68°C 155°F/68°C 200°F/93°C 175°F/79°C 2 F/C 175°F/79°C 175°F/79°C 286°F/141°C 200°F/93°C 286'F/141°C 200°F/93°C 200°F/93°C 360°F/182°C 135°F/57°C 135°F/57°C 155°F/68°C 135°F/57°C 155°F/68°C 135°F/57°C FM 6 175°F/79°C 155°F/68°C 175°F/79°C 155°F/68°C None 200°F/93°C 175°F/79°C 2 F/ C 175°F/79°C 286°F/141°C 200°F/93°C 286*F/141°C 200°F/93°C 360°F/182°C 135°F/57°C 135°F/57°C 155°F/68°C 135°F/57°C 155°F/68°C 135°F/57°C 135°F/57°C NYC/M EA 6 #62 99 E 175°F/79°C 155°F/68°C 175°F/79°C 155°F/68°C 155°F/68°C 200°F/93°C 175°F/79°C 2 F/C 175°F/79°C 175°F/79°C 286°F/141°C 200°F/93°C 286*F/141°C 200°F/93°C 200°F/93°C 360°F/182°C 135°F/57°C 135°F/57°C 155°F/68°C 135°F/57°C 155°F/68°C 135°F/57°C 135°F/57°C CSFM 6 #7690 0531:112 175°F/79°C 155°F/68°C 175°F/79°C 155°F/68°C 155°F/68°C 200°F/93°C 175°F/79°C 2 F/C 175°F/79°C 175°F/79°C 286°F/141°C 200°F/93°C 286*F/141°C 200°F/93°C 200°F/93°C 360°F/182°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C LPCB 6104b/01 175°F/79°C None 175°F/79°C None None 6104b/02 200°F/93°C 286°F/141°C 00 200°F/93° C 93 360°F/182°C 2 F/ C 135°F/57°C 135°F/57°C 155°F/68°C 135°F/57°C 155°F/68°C 135°F/57°C VNIIPO 175°F/79°C 155°F/68°C 175°F/79°C 155°F/68°C None 200°F/93°C 175°F/79°C 2 F/C 175°F/79°C 286°F/141°C 200°F/93°C 286*F/141°C 200°F/93°C 360°F/182°C CCU ZSTBS None None None None 155°F/68°C 5 For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 6 Light Hazard ONLY Note: Listings and Approvals as of printing. All are approved open. 40.11 2545 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 3 iCtSU1_iC® victaulic.com I Sprinklers I Fire Lock® I K5.6, V27 I Publication 40.11 ulmensions: 3"/89 mm 57 mm 1'A 8 mm. 11 mm 32mrn L -- — — _- Standard HSW — V2709, V2710 11/16"7 7mm 56 rnrn J 43 mm1/16'430 mm7 56 mm Finished Ceiling I Finished Ceiling 4 - 12"1102 - 305 mm 4 - 12"7102 - 305 mm Per NFPA Per NFPA 2751 mm 23/8760 mm 215/16"/ 2°751 mm 23/8"760 mm Min. Hole Max. Hole 75 mm Min. Hole Max. Hole Finished Surface I Finished Surfaces � I �I I�Typical Wall F�Typical Wall MAXIMUM EXTENSION MAXIMUM RECESS 1/2" Adjustment Recessed — V2709, V2710 (drawing not to scale) 15/1 24 mm 23/167 9/16718 mm 7/16" 5/16",- 56 mm 37mm 37mm Finished Ceiling Finished Ceiling 4 - 127102 - 305 mm 4 - 12"7102 - 305— Per NFPA Per NFPA -0-42751 mm 23/8"/60 mm 215/167 II� 2751 mm 23/8"/60 mm Min. Hole Max. Hole 75 mm Min. Hole Max. Hole Finished Surface Finished Surface - Typical Wall �J Typical Wall MAXIMUM EXTENSION MAXIMUM RECESS 3/4" Adjustment Recessed — V2709, V2710 (drawing not to scale) 40.11 2545 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 4 iCtsulid victaulic.com I Sprinklers I Fire Lock® I K5.6, V27 I Publication 40.11 Distribution Patterns: 10, 3.0 m Models V2709, V2710 K5.6 Standard Horizontal Sidewall and Recessed Horizontal Sidewall Distribution Patterns - Trajectory 0 2' 4' 6' 8' 10, 12' 14' 16' 18' 20' 22' 24' 26' 0,6m 1,2m 1,8m 2.4m 3.0m 3.7m 4.3m 4.9m 5.5m 6.1m 6.7m 7.3m 7.9m 2' 0.6 m 4' 1.2 m 6' 1.8 m 8' 2A m 10, 3.0 m 12' 3.7 m 14' 4.3 m 16' 4.9 m Models V2709, V2710 K5.6 Standard and Recessed Horizontal Sidewall Distribution Patterns - Plan View 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 28' 0.6m 1.2m 1.8m 2Am 3.0m 3.7m 4.3m 4.9m 5.5m 6.1 m 6.7m 7.3m 7.9m 8.5m 7psi �••�••' 48 kPa 15 psi 103 kPa 30psi ...mmmm 207 kPa 7psi �••�••' 48 kPa 15 psi 103 kPa 30psi ....... 207 kPa NOTES: A. Data shown is approximate and can vary due to differences in installation. B. These graphs illustrate approximate trajectories, floor -wetting, and wall -wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. 40.11 2545 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 5 ictaUI_iC' victaulic.com I Sprinklers I Fire Lock® I K5.6, V27 I Publication 40.11 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67T (-55°C) to those shown in the table below. Temperature - °F/°C7GIass No escutcheon Sprinkler Victaulic Nominal MaximumWith Ambient escutcheon Temperature Part Temperature Temperature Bulb Classification Identification Rating Allowed Color Ordinary A 135°F/57°C 100°F/38°C Orange Ordinary C 155°111 100°F/38°C Red Intermediate E 17501 151 Yellow Intermediate F 200°111 151 Green High J 286' 141°C 225°F/107oC Blue Extra High 7 K 3600 1820C 300°F/149°C Purple - M Open - No Bulb 7 Standard response only. V27-2 V27 Recessed Open End A WARNING • Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. • Installation rules, especially those governing obstruction, must be strictly followed. • Painting, plating, or any re -coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 0OISE 001-610-559-3300. Installation Note Reference should always be made to the 1-40 Victaulic Fire Lock Automatic Sprinklers This product shall be manufactured by Victaulic or to Victaulic specifications. All products Installation and Maintenance Sheet for the product you are installing. This installation sheet to be installed in accordance with current Victaulic installation/assembly instructions. is included with each shipment of Victaulic products for complete installation and assembly Victaulic reserves the right to change product specifications, designs and standard data, and is available in PDF format on our website at victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic is a registered trademark of Victaulic Company. 40.11 2545 Rev. J Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 6 ictauI c®