Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2022-0508_Manufacturer_Specifications_and_Installation_Instructions_4.20.2022_8.40.07_PM_2817395
VP rOA/K/N ■ Standard Features • Heavy-duty stainless -steel dual -diameter, tubular heat exchanger • Two -stage gas valve provides quiet, economical heating • Durable Silicon Nitride igniter • Quiet two -speed draft inducer • Self -diagnostic control board • Efficient and quiet multi -speed airflow system • Multiple continuous fan speed options offer quiet air circulation • California Low NOx emissions -compliant models available • Can no longer be installed in California's South Coast Air Quality Management District (SCAQMD) on or after October 1,2019 • AHRI Certified; ETL Listed DM80VE / DC80VE TWO -STAGE, MULTI -SPEED ECM GAS FURNACE 80% AFUE HEATING INPUT.- 40, 000-120, 000 BTU/H ■ Contents Nomenclature.............................................2 Product Specifications................................3 Dimensions.................................................5 Airflow Data................................................7 Wiring Diagram ....................................... 20 Accessories...............................................21 ■ Cabinet Features • Multi -position installation: DM80VE: Upflow, horizontal left or right. DC80VE: Downflow, horizontal left or right. Convenient left or right connection for gas and electrical service • Cabinet air leakage (QLeak) <_ 2% • Heavy -gauge steel cabinet with durable baked -enamel finish • Fully insulated heat exchanger and blower section � � � IS09001 ce.ro�eo Intertek ^-- * Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), the 6-Year Unit Replacement Limited Warranty and the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Additional requirements for annual maintenance are required forthe Unit Replacement Limited Warranty. Online registration and some of the additional requirements are not required in California or Quebec. SS-DM80VE www.daikincomfort.com 02/21 Supersedes 07/20 NOMENCLATURE D M 80 V E 060 3 A X 1 2 Brand D - Daikin Brand Configuration M - Upflow/Horizontal C - Downflow/Horizontal D - Dedicated Downflow AFUE 97 — 97-98% AFUE 92-92%AFUE 96-96%AFUE 80-80%AFUE Gas Valve 3,4 5 6 7,8,9 10 11 12 M - Modulating H - Convertible Two -Stage V - Two Stage S - Single Stage Motor C - Variable Speed ECM / Communicating E - Multi -Speed ECM S - Multi -Speed PSC M BTU/h 040 - 40,000 BTU/h 100 - 100,000 BTU/h 060 - 60,000 BTU/h 120 - 120,000 BTU/h 080 - 80,000 BTU/h 140 - 140,000 BTU/h 13 14 Minor Revision A - Initial Release B - 1st Revision Major Revision A - Initial Release B - 1st Revision NOx N -Natural Gas X - Low NOx Cabinet Width A-14" C-21" B-17%" D-24W' Maximum CFM 2 - 800 CFM 3-1200CFM 4-1600CFM 5 - 2000 CFM 2 www.daikincomfort.com SS-DM80VE PRODUCT SPECIFICATIONS HEATING CAPACITY High Fire Input (BTU/h)' 40,000 60,000 80,000 80,000 80,000 100,000 120,000 High Fire Output (BTU/h)' (below) Natural Gas 32,000 48,000 64,000 64,000 64,000 80,000 96,000 LP Gas 32,000 48,000 64,000 64,000 64,000 80,000 96,000 Low Fire Input (BTU/h)' 28,000 42,000 56,000 56,000 56,000 70,000 84,000 Low Fire Output (BTU/h)' (below) Natural Gas 22,400 33,600 44,800 44,800 44,800 56,000 67,200 LP Gas 22,400 33,600 44,800 44,800 44,800 56,000 67,200 AFUE' 80 80 80 80 80 80 80 Available AC@0.5"ESP 1.5-3.0 1.5-4.0 3.0-4.0 2.5-5.0 2.5-5.0 2.0-5.0 2.0-5.0 Temperature Rise Range (° F) 15-45 / 15-45 15-45 / 15-45 30-60 / 30-60 25-55 / 25-55 20-50 / 20-50 20-50 / 20-50 40-70 / 40-70 CIRCULATOR BLOWER Size (DxW) 10"x6" 10"x8" 101.x8" 10"x10" 11"x10" 10"x10" 11"x10" Horsepower- RPM 1/2 1/2 1/2 3/4 3/4 1 1 Speed 5 5 5 5 5 5 5 Vent Diameter' 4" 4" 4" 4" 4" 4" 4" No. of Burners 3 3 4 4 4 5 6 ELECTRICAL DATA Min. CircuitAmpacity° 8.7 8.7 8.7 15.32 15.32 15.32 15.32 Max. Overcurrent Device (amps)' 15 15 15 20 20 20 20 SHIP WEIGHT(LBS) 105 107 118 129 129 124 124 Low -fire rate is 75% of high -fire rate. Natural Gas BTU/h; for altitudes 0-4500' above sea level, reduce input rating by 4%for each 1000' above 4500' altitude. z DOE AFUE based upon Isolated Combustion System (ICS) ' Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). ° Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. s Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. • Gas Service Connection %" FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. SS-DM80VE www.daikincomfort.com 3 PRODUCT SPECIFICATIONS HEATING CAPACITY High Fire Input (BTU/h)' 40,000 60,000 60,000 80,000 80,000 100,000 High Fire Output (BTU/h)' (below) Natural Gas 32,000 48,000 48,000 64,000 64,000 80,000 LP Gas 32,000 48,000 48,000 64,000 64,000 80,000 Low Fire Input (BTU/h)' 28,000 42,000 42,000 56,000 56,000 70,000 Low Fire Output (BTU/h)l (below) Natural Gas 22,400 33,600 33,600 44,800 44,800 56,000 LP Gas 22,400 33,600 33,600 44,800 44,800 56,000 AFUE2 80 80 80 80 80 80 Available AC@0.5"ESP 1.5-3.0 1.5-4.0 1.5-4.0 2.0-5.0 2.5-5.0 2.0-5.0 Temperature Rise Range (° F) 15-45 / 15-45 30-60 / 30-60 25-55 / 25-55 30-60 / 30-60 30-60 / 30-60 20-50 / 20-50 CIRCULATOR BLOWER Size (DxW) 10"x6" 10"x6" 10"x8" 10"x10" 10"x10" 10"x10" Horsepower - RPM 1/2 % 1/2 3/4 3/4 1 Speed 5 5 5 5 5 5 Vent Diameter' 4" 4" 4" 4" 4" 4" No. of Burners 3 3 3 4 4 5 ELECTRICAL DATA Min. CircuitAmpacity° 8.7 8.7 8.7 12.45 15.32 15.32 Max. Overcurrent Device (amps) 5 15 15 15 15 20 20 SHIP WEIGHT (LBS) 105 107 107 121 129 124 Low -fire rate is 75% of high -fire rate. Natural Gas BTU/h; for altitudes 0-4500' above sea level, reduce input rating by 4%for each 1000' above 4500' altitude. z DOE AFUE based upon Isolated Combustion System (ICS) 3 Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). ° Minimum Circuit Ampacity= (1.25 x Circulator Blower Amps)+ ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. s Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. • Gas Service Connection W' FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. 4 www.daikincomfort.com SS-DM80VE I�71�E:i�l9�i u Alternate Gas Inlet Alt. Flue Outlet — Horizontal Left A 1 /6 11 B 19Y=" 1 33%" Alt. Gas Inlet High -Voltage Inlet 20 ! l 235/16' Alt. High Voltage 13'%" 15" Low -Voltage Inlet Alt. Low Voltage 23„ 28" - .. DM80VE0403A* DIMENSIONS 14" 12%" DM80VE0603B* 17%" 16" DM80VE0803B* 17%" 16" DM80VE0805C* 21" 19%" DM80VE0805D* 24%" 23" DM80VE1005C* 21" 19%" DM80VE1205D* 24%" 23" MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS C = If placed on combustible floor, the floor MUST be wood ONLY NOTES • For servicing or cleaning, a 24" front clearance is recommended. • Unit connections (electrical, flue, and drain) may necessitate greater clearances than the minimum clearances listed above. • In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. • Refer to the appropriate USA and Canadian codes: • In the USA: the National Fuel Gas Code NFPA 54 / ANSI Z223.1 • In Canada: the Canada National Standard of Canada, CAN/CSA 3149.1 and CAN/CSA B142.2 SS-DM80VE www.daikincomfort.com 5 I�Z�:�i]�/�i u]�i7►� 118%" 1. A B 33 W 28" 19%" High -Voltage Electrical Low -Voltage , Electrical Gas Inlet . . O 0 0 O 0 0 0 DC80VE0403A* DIMENSIONS 14" 12%" DC80VE0603A* 14" 12%" DC80VE0603B* 17%" 16" DC80VE0804B* 17%" 16" DC80VE0805C* 21" 19%" DC80VE1005C* 21" 19%" MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS C = If placed on combustible floor, the floor MUST be wood ONLY. Notes: • For servicing or cleaning, a 24" front clearance is recommended. • Unit connections (electrical, flue, and drain) may necessitate greater clearances than the minimum clearances listed above. • In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. • Refer to the appropriate USA and Canadian codes: In the USA: the National Fuel Gas Code NFPA 54 / ANSI Z223.1 In Canada: the Canada National Standard of Canada, CAN/CSA 13149.1 and CAN/CSA 6142.2 www.daikincomfort.com SS-DM80VE id # "AA1D A rA PCBBF139 DM80VE0403A* - COOLING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM S1-1 S1-2 S1-3 Ylo 1138 1093 1057 1016 981 945 912 876 OFF OFF OFF* Y 1367 1321 1286 1255 1223 1190 1160 1133 Ylo 923 865 824 802 759 715 674 631 ON OFF OFF Y 1138 1093 1057 1016 981 945 912 876 Ylo 923 865 824 802 759 715 674 631 ON ON OFF Y 1367 1321 1286 1255 1223 1190 1160 1133 Ylo 1138 1093 1057 1016 981 945 912 876 OFF ON OFF Y 553 496 436 372 308 252 198 N/A Ylo 1138 1093 1057 1016 981 945 912 876 OFF OFF ON Y 750 703 651 600 553 504 456 409 Ylo 923 865 824 802 759 715 674 631 OFF ON ON Y 553 496 436 372 308 252 198 N/A Ylo 750 703 651 600 553 504 456 409 ON OFF ON Y 1367 1321 1286 1255 1223 1190 1160 1133 Ylo 750 703 651 600 553 504 456 409 ON ON ON Y 923 865 824 802 759 715 674 631 *DEFAULT PCBBF139 DM80VE0403A* - CONTINOLIS FAN DIP SWITCHES S2-2 S2-3 S2-4 STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM G 553 496 436 372 308 252 198 N/A ON OFF OFF G 750 703 651 600 553 504 456 409 ON ON OFF G 923 865 824 802 759 715 674 631 OFF ON OFF G 1138 1093 1057 1016 981 945 912 876 OFF OFF ON G 1367 1321 1286 1255 1223 1190 1160 1133 OFF ON ON G 553 496 436 372 308 252 198 N/A ON OFF ON G 553 496 436 372 308 252 198 N/A ON ON ON G 553 496 436 372 308 252 198 N/A PCBBF139 DM80VE0403A* - HEATING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S1-4 S2-1 TsTAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 553 38 496 42 436 N/A 372 N/A 308 N/A 252 198 N/A OFF OFF* W2 750 40 703 42 651 N/A 600 N/A 553 N/A 504 456 409 W1 923 22 865 24 824 25 802 26 759 27 715 674 631 ON OFF W2 750 40 703 42 651 N/A 600 N/A 553 N/A 504 456 409 W1 923 22 865 24 824 25 802 26 759 27 715 674 631 ON ON W2 1138 26 1093 27 1057 28 1016 29 981 30 945 912 876 W1 1138 N/A 1093 N/A 1057 N/A 1016 N/A 981 N/A 945 912 876 OFF ON** W2 1367 N/A 1321 N/A 1286 N/A 1255 N/A 1223 N/A 1190 1160 1133 *DEFAULT **NOT RECOMMENDED NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For mostjobs, about 400 CFM per ton when coaling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. SS-DM80VE www.daikincomfort.com DM80VE AIRFLOW DATA (CONT.) PCBBF139 DM80VE0603B* - COOLING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM S1-1 S1-2 S1-3 Y10 1330 1280 1229 1187 1146 1103 1061 1018 OFF OFF OFF* Y 1465 1416 1382 1340 1299 1278 1257 1219 Ylo 737 661 589 531 456 384 313 252 ON OFF OFF Y 1330 1280 1229 1187 1146 1103 1061 1018 Y10 737 661 589 531 456 384 313 252 ON ON OFF Y 1465 1416 1382 1340 1299 1278 1257 1219 Ylo 1330 1280 1229 1187 1146 1103 1061 1018 OFF ON OFF Y 1155 1100 1048 1002 952 907 861 816 Ylo 1330 1280 1229 1187 1146 1103 1061 1018 OFF OFF ON Y 1418 1376 1333 1288 1248 1206 1163 1124 Ylo 737 661 589 531 456 384 313 252 OFF ON ON Y 1155 1100 1048 1002 952 907 861 816 Y10 1418 1376 1333 1288 1248 1206 1163 1124 ON OFF ON Y 1465 1416 1382 1340 1299 1278 1257 1219 Y10 1418 1376 1333 1288 1248 1206 1163 1124 ON ON ON Y 737 661 589 531 456 384 313 252 *DEFAULT PCBBF139 DM80VE0603B* - CONTINOUS FAN DIP SWITCHES S2-2 S2-3 S2-4 STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM G 1155 1100 1048 1002 952 907 861 816 ON OFF OFF G 1418 1376 1333 1288 1248 1206 1163 1124 ON ON OFF G 737 661 589 531 456 384 313 252 OFF ON OFF G 1330 1280 1229 1187 1146 1103 1061 1018 OFF OFF ON G 1465 1416 1382 1340 1299 1278 1257 1219 OFF ON ON G 1155 1100 1048 1002 952 907 861 816 ON OFF ON G 1155 1100 1048 1002 952 907 861 816 ON ON ON G 1155 1100 1048 1002 952 907 861 816 PCBBF139 DM80VE0603B* - HEATING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S1-4 S2-1 TsTAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 1155 27 1100 28 1048 30 1002 31 952 33 907 861 816 OFF OFF* W2 1418 31 1376 32 1333 33 1288 35 1248 36 1206 1163 1124 W1 737 42 661 N/A 589 N/A 531 N/A 456 N/A 384 313 252 ON OFF W2 1418 31 1376 32 1333 33 1288 35 1248 36 1206 1163 1124 W1 737 42 661 N/A 589 N/A 531 N/A 456 N/A 384 313 252 ON ON W2 1330 33 1280 35 1229 36 1187 37 1146 39 1103 1061 1018 W1 1330 N/A 1280 N/A 1229 N/A 1187 N/A 1146 N/A 1103 1061 1018 OFF ON** W2 1465 N/A 1416 N/A 1382 N/A 1340 N/A 1299 N/A 1278 1257 1219 *DEFAULT **NOT RECOMMENDED NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For mostjobs, about 400 CFM per ton when coaling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. www.daikincomfort.com SS-DM80VE DMSOVE AIRFLOW DATA (CONT.) PCBBF139 DM80VE0803B* - COOLING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM S1-1 S1-2 S1-3 Ylo 1160 1107 1060 1011 965 920 868 818 OFF OFF OFF* Y 1231 1185 1136 1093 1049 1004 956 908 Ylo 706 631 563 486 404 338 280 232 ON OFF OFF Y 1160 1107 1060 1011 965 920 868 818 Ylo 706 631 563 486 404 338 280 232 ON ON OFF Y 1231 1185 1136 1093 1049 1004 956 908 Ylo 1160 1107 1060 1011 965 920 868 818 OFF ON OFF Y 1133 1009 956 903 856 804 774 722 Ylo 1160 1107 1060 1011 965 920 868 818 OFF OFF ON Y 1402 1358 1317 1274 1234 1195 1154 1113 Ylo 706 631 563 486 404 338 280 232 OFF ON ON Y 1133 1009 956 903 856 804 774 722 Ylo 1402 1358 1317 1274 1234 1195 1154 1113 ON OFF ON Y 1231 1185 1136 1093 1049 1004 956 908 Ylo 1402 1358 1317 1274 1234 1195 1154 1113 ON ON ON Y 706 631 563 486 404 338 280 232 *DEFAULT PCBBF139 DM80VE0803B* - CONTINOUS FAN DIP SWITCHES S2-2 S2-3 S2-4 STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM G 1133 1009 956 903 856 804 774 722 ON OFF OFF G 1402 1358 1317 1274 1234 1195 1154 1113 ON ON OFF G 706 631 563 486 404 338 280 232 OFF ON OFF G 1160 1107 1060 1011 965 920 868 818 OFF OFF ON G 1231 1185 1136 1093 1049 1004 956 908 OFF ON ON G 1133 1009 956 903 856 804 774 722 ON OFF ON G 1133 1009 956 903 856 804 774 722 ON ON ON G 1133 1009 956 903 856 804 774 722 PCBBF139 DM80VE0803B* - HEATING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S1-4 S2-1 TsTAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 1133 37 1009 41 956 43 903 46 856 48 804 774 722 OFF OFF* W2 1402 42 1358 44 1317 45 1274 47 1234 48 1195 1154 1113 W1 706 N/A 631 N/A 563 N/A 486 N/A 404 N/A 338 280 232 ON OFF** W2 1402 N/A 1358 N/A 1317 N/A 1274 N/A 1234 N/A 1195 1154 1113 W1 706 N/A 631 N/A 563 N/A 486 N/A 404 N/A 338 280 232 ON ON** W2 1160 N/A 1107 N/A 1060 N/A 1011 N/A 965 N/A 920 868 818 W1 1160 36 1107 37 1060 39 1011 41 965 43 920 868 818 OFF ON W2 1231 48 1185 50 1136 52 1093 54 1049 56 1004 956 908 *DEFAULT **NOT RECOMMENDED NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For mostjobs, about 400 CFM per ton when coaling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. SS-DM80VE www.daikincomfort.com DM80VE AIRFLOW DATA (CONT.) PCBBF139 DM80VE0805D* - COOLING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM S1-1 S1-2 S1-3 Y10 1698 1621 1553 1497 1437 1393 1328 1270 OFF OFF OFF* Y 2266 2202 2143 2090 2040 1995 1945 1896 Ylo 1088 999 899 772 667 561 490 418 ON OFF OFF Y 1698 1621 1553 1497 1437 1393 1328 1270 Y10 1088 999 899 772 667 561 490 418 ON ON OFF Y 2266 2202 2143 2090 2040 1995 1945 1896 Ylo 1698 1621 1553 1497 1437 1393 1328 1270 OFF ON OFF Y 1450 1382 1314 1243 1181 1115 1047 973 Y10 1698 1621 1553 1497 1437 1393 1328 1270 OFF OFF ON Y 1886 1822 1758 1701 1646 1591 1535 1482 Y10 1088 999 899 772 667 561 490 418 OFF ON ON Y 1450 1382 1314 1243 1181 1115 1047 973 Y10 1886 1822 1758 1701 1646 1591 1535 1482 ON OFF ON Y 2266 2202 2143 2090 2040 1995 1945 1896 Y10 1886 1822 1758 1701 1646 1591 1535 1482 ON ON ON Y 1088 999 899 772 667 561 490 418 *DEFAULT PCBBF139 DM80VE0805D* - CONTINOUS FAN DIP SWITCHES S2-2 S2-3 S2-4 STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM G 1450 1382 1314 1243 1181 1115 1047 973 ON OFF OFF G 1886 1822 1758 1701 1646 1591 1535 1482 ON ON OFF G 1088 999 899 772 667 561 490 418 OFF ON OFF G 1698 1621 1553 1497 1437 1393 1328 1270 OFF OFF ON G 2266 2202 2143 2090 2040 1995 1945 1896 OFF ON ON G 1450 1382 1314 1243 1181 1115 1047 973 ON OFF ON G 1450 1382 1314 1243 1181 1115 1047 973 ON ON ON G 1450 1382 1314 1243 1181 1115 1047 973 PCBBF139 DM80VE0805D* - HEATING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S1-4 S2-1 TsTAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 1450 29 1382 30 1314 32 1243 33 1181 35 1115 1047 973 OFF OFF* W2 1886 31 1822 33 1758 34 1701 35 1646 36 1591 1535 1482 W1 1088 38 999 42 899 46 772 N/A 667 N/A 561 490 418 ON OFF W2 1886 31 1822 33 1758 34 1701 35 1646 36 1591 1535 1482 W1 1088 38 999 42 899 46 772 N/A 667 N/A 561 490 418 ON ON W2 1698 35 1621 37 1553 38 1497 40 1437 41 1393 1328 1270 W1 1698 24 1621 26 1553 27 1497 28 1437 29 1393 1328 1270 OFF ON W2 2266 26 2202 27 2143 28 2090 28 2040 29 1995 1945 1896 *DEFAULT NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For mostjobs, about 400 CFM per ton when coaling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 10 www.daikincomfort.com SS-DM80VE DMSOVE AIRFLOW DATA (CONT.) PCBBF139 DM80VE0805C* - COOLING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM S1-1 S1-2 S1-3 Y10 1583 1536 1515 1478 1434 1383 1317 1265 OFF OFF OFF* Y 2145 2089 2058 2036 2020 2000 1971 1935 Ylo 1171 884 667 576 495 399 338 302 ON OFF OFF Y 1583 1536 1515 1478 1434 1383 1317 1265 Y10 1171 884 667 576 495 399 338 302 ON ON OFF Y 2145 2089 2058 2036 2020 2000 1971 1935 Y10 1583 1536 1515 1478 1434 1383 1317 1265 OFF ON OFF Y 1436 1402 1362 1313 1244 1182 1132 1079 Ylo 1583 1536 1515 1478 1434 1383 1317 1265 OFF OFF ON Y 1782 1744 1715 1700 1660 1619 1579 1510 Ylo 1171 884 667 576 495 399 338 302 OFF ON ON Y 1436 1402 1362 1313 1244 1182 1132 1079 Y10 1782 1744 1715 1700 1660 1619 1579 1510 ON OFF ON Y 2145 2089 2058 2036 2020 2000 1971 1935 Ylo 1782 1744 1715 1700 1660 1619 1579 1510 ON ON ON Y 1171 884 667 576 495 399 338 302 *DEFAULT PCBBF139 DM80VE0805C* - CONTINOUS FAN DIP SWITCHES S2-2 S2-3 S2-4 STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM G 1436 1402 1362 1313 1244 1182 1132 1079 ON OFF OFF G 1782 1744 1715 1700 1660 1619 1579 1510 ON ON OFF G 1171 884 667 576 495 399 338 302 OFF ON OFF G 1583 1536 1515 1478 1434 1383 1317 1265 OFF OFF ON G 2145 2089 2058 2036 2020 2000 1971 1935 OFF ON ON G 1436 1402 1362 1313 1244 1182 1132 1079 ON OFF ON G 1436 1402 1362 1313 1244 1182 1132 1079 ON ON ON G 1436 1402 1362 1313 1244 1182 1132 1079 PCBBF139 DM80VE0805C* - HEATING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S1-4 S2-1 TsTAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 1436 29 1402 30 1362 30 1313 32 1244 33 1182 1132 1079 OFF OFF* W2 1782 33 1744 34 1715 35 1700 35 1660 36 1619 1579 1510 W1 1171 35 884 47 667 N/A 576 N/A 495 N/A 399 338 302 ON OFF W2 1782 33 1744 34 1715 35 1700 35 1660 36 1619 1579 1510 W1 1171 35 884 47 667 N/A 576 N/A 495 N/A 399 338 302 ON ON W2 1583 37 1536 39 1515 39 1478 40 1434 41 1383 1317 1265 W1 1583 N/A 1536 N/A 1515 N/A 1478 N/A 1434 N/A 1383 1317 1265 OFF ON** W2 2145 N/A 2089 N/A 2058 N/A 2036 N/A 2020 N/A 2000 1971 1935 *DEFAULT **NOT RECOMMENDED NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For mostjobs, about 400 CFM per ton when coaling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. SS-DM80VE www.daikincomfort.com 11 DM80VE AIRFLOW DATA (CONT.) PCBBF139 DM80VE1205D* - COOLING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM S1-1 S1-2 S1-3 Ylo 1627 1566 1520 1470 1420 1398 1391 1343 OFF OFF OFF* Y 2226 2165 2126 2083 2048 2011 1983 1945 Ylo 815 742 662 590 503 422 362 299 ON OFF OFF Y 1627 1566 1520 1470 1420 1398 1391 1343 Ylo 815 742 662 590 503 422 362 299 ON ON OFF Y 2226 2165 2126 2083 2048 2011 1983 1945 Ylo 1627 1566 1520 1470 1420 1398 1391 1343 OFF ON OFF Y 1381 1324 1274 1220 1164 1137 1109 1049 Ylo 1627 1566 1520 1470 1420 1398 1391 1343 OFF OFF ON Y 1831 1770 1723 1677 1630 1590 1547 1506 Ylo 815 742 662 590 503 422 362 299 OFF ON ON Y 1381 1324 1274 1220 1164 1137 1109 1049 Ylo 1831 1770 1723 1677 1630 1590 1547 1506 ON OFF ON Y 2226 2165 2126 2083 2048 2011 1983 1945 Ylo 1831 1770 1723 1677 1630 1590 1547 1506 ON ON ON Y 815 742 662 590 503 422 362 299 *DEFAULT PCBBF139 DM80VE1205D* - CONTINOUS FAN DIP SWITCHES S2-2 S2-3 S2-4 STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM G 1381 1324 1274 1220 1164 1137 1109 1049 ON OFF OFF G 1831 1770 1723 1677 1630 1590 1547 1506 ON ON OFF G 815 742 662 590 503 422 362 299 OFF ON OFF G 1627 1566 1520 1470 1420 1398 1391 1343 OFF OFF ON G 2226 2165 2126 2083 2048 2011 1983 1945 OFF ON ON G 1381 1324 1274 1220 1164 1137 1109 1049 ON OFF ON G 1381 1324 1274 1220 1164 1137 1109 1049 ON ON ON G 1381 1324 1274 1220 1164 1137 1109 1049 PCBBF139 DM80VE1205D* - HEATING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S1-4 S2-1 TsTAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 1381 45 1324 47 1274 49 1220 51 1164 53 1137 1109 1049 OFF OFF* W2 1831 49 1770 50 1723 52 1677 53 1630 55 1590 1547 1506 W1 815 N/A 742 N/A 662 N/A 590 N/A 503 N/A 422 362 299 ON OFF** W2 1831 N/A 1770 N/A 1723 N/A 1677 N/A 1630 N/A 1590 1547 1506 W1 815 N/A 742 N/A 662 N/A 590 N/A 503 N/A 422 362 299 ON ON** W2 1627 N/A 1566 N/A 1520 N/A 1470 N/A 1420 N/A 1398 1391 1343 W1 1627 38 1566 40 1520 41 1470 42 1420 44 1398 1391 1343 OFF ON W2 2226 40 2165 41 2126 42 2083 43 2048 43 2011 1983 1945 *DEFAULT **NOT RECOMMENDED NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For mostjobs, about 400 CFM per ton when coaling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 12 www.daikincomfort.com SS-DM80VE h7�.7►►li e e PCBBF139 DC80VE0403A* - COOLING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM S1-1 S1-2 S1-3 Y10 785 754 736 690 650 604 565 527 OFF OFF OFF* Y 1348 1294 1261 1250 1229 1233 1205 1182 Ylo 663 647 597 551 501 458 408 355 ON OFF OFF Y 785 754 736 690 650 604 565 527 Y10 663 647 597 551 501 458 408 355 ON ON OFF Y 1348 1294 1261 1250 1229 1233 1205 1182 Ylo 785 754 736 690 650 604 565 527 OFF ON OFF Y 591 568 518 463 411 355 300 243 Ylo 785 754 736 690 650 604 565 527 OFF OFF ON Y 1104 1058 1020 1022 1013 981 952 918 Ylo 663 647 597 551 501 458 408 355 OFF ON ON Y 591 568 518 463 411 355 300 243 Y10 1104 1058 1020 1022 1013 981 952 918 ON OFF ON Y 1348 1294 1261 1250 1229 1233 1205 1182 Y10 1104 1058 1020 1022 1013 981 952 918 ON ON ON Y 663 647 597 551 501 458 408 355 *DEFAULT PCBBF139 DC80VE0403A* - CONTINUOUS FAN DIP SWITCHES S2-2 S2-3 S2-4 STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM OFF OFF OFF G 591 568 518 463 411 355 300 243 ON OFF OFF G 1104 1058 1020 1022 1013 981 952 918 ON ON OFF G 663 647 597 551 501 458 408 355 OFF ON OFF G 785 754 736 690 650 604 565 527 OFF OFF ON G 1348 1294 1261 1250 1229 1233 1205 1182 OFF ON ON G 591 568 518 463 411 355 300 243 ON OFF ON G 591 568 518 463 411 355 300 243 ON ON ON G 591 568 518 463 411 355 300 243 PCBBF139 DC80VE0403A* - HEATING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S1-4 S2-1 TsTAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 591 35 568 37 518 40 463 45 411 N/A 355 300 243 OFF OFF* W2 1104 27 1058 28 1020 29 1022 29 1013 29 981 952 918 W1 663 31 647 32 597 35 551 38 501 41 458 408 355 ON OFF W2 1104 27 1058 28 1020 29 1022 29 1013 29 981 952 918 W1 663 31 647 32 597 35 551 38 501 41 458 408 355 ON ON W2 785 38 754 39 736 40 690 43 650 N/A 604 565 527 W1 785 26 754 28 736 28 690 30 650 32 604 565 527 OFF ON W2 1348 22 1294 23 1261 23 1250 24 1229 24 1233 1205 1182 *DEFAULT NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For mostjobs, about 400 CFM per ton when coaling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. See Notes on page 10. SS-DM80VE www.daikincomfort.com 13 DCSOVE AIRFLOW DATA (CONT.) PCBBF139 DC80VE0603A*- COOLING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM S1-1 S1-2 S1-3 Y10 1160 1102 1055 1017 970 930 891 847 OFF OFF OFF* Y 1411 1356 1313 1272 1235 1198 1162 1127 Ylo 656 589 532 465 402 348 271 219 ON OFF OFF Y 1160 1102 1055 1017 970 930 891 847 Y10 656 589 532 465 402 348 271 219 ON ON OFF Y 1411 1356 1313 1272 1235 1198 1162 1127 Ylo 1160 1102 1055 1017 970 930 891 847 OFF ON OFF Y 716 647 592 541 478 420 368 296 Ylo 1160 1102 1055 1017 970 930 891 847 OFF OFF ON Y 1054 1002 951 906 861 820 797 754 Ylo 656 589 532 465 402 348 271 219 OFF ON ON Y 716 647 592 541 478 420 368 296 Y10 1054 1002 951 906 861 820 797 754 ON OFF ON Y 1411 1356 1313 1272 1235 1198 1162 1127 Ylo 1054 1002 951 906 861 820 797 754 ON ON ON Y 656 589 532 465 402 348 271 219 *DEFAULT PCBBF139 DC80VE0603A* - CONTINOUS FAN DIP SWITCHES S2-2 S2-3 S2-4 STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM G 716 647 592 541 478 420 368 296 ON OFF OFF G 1054 1002 951 906 861 820 797 754 ON ON OFF G 656 589 532 465 402 348 271 219 OFF ON OFF G 1160 1102 1055 1017 970 930 891 847 OFF OFF ON G 1411 1356 1313 1272 1235 1198 1162 1127 OFF ON ON G 716 647 592 541 478 420 368 296 ON OFF ON G 716 647 592 541 478 420 368 296 ON ON ON G 716 647 592 541 478 420 368 296 PCBBF139 DC80VE0603A* - HEATING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S1-4 S2-1 TsTAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 716 43 647 48 592 53 541 58 478 N/A 420 368 296 OFF OFF* W2 1054 42 1002 44 951 47 906 49 861 52 820 797 754 W1 656 47 589 53 532 58 465 N/A 402 N/A 348 271 219 ON OFF W2 1054 42 1002 44 951 47 906 49 861 52 820 797 754 W1 656 47 589 53 532 58 465 N/A 402 N/A 348 271 219 ON ON W2 1160 38 1102 40 1055 42 1017 44 970 46 930 891 847 W1 1160 N/A 1102 N/A 1055 N/A 1017 N/A 970 N/A 930 891 847 OFF ON** W2 1411 N/A 1356 N/A 1313 N/A 1272 N/A 1235 N/A 1198 1162 1127 *DEFAULT **NOT RECOMMENDED NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For mostjobs, about 400 CFM per ton when coaling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 14 www.daikincomfort.com SS-DM80VE DCSOVE AIRFLOW DATA (CONT.) PCBBF139 DC80VE0603B* - COOLING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM S1-1 S1-2 S1-3 Ylo 1223 1144 1081 995 918 839 798 738 OFF OFF OFF* Y 1395 1332 1272 1207 1136 1074 1007 948 Ylo 1032 800 578 487 387 301 235 151 ON OFF OFF Y 1223 1144 1081 995 918 839 798 738 Ylo 1032 800 578 487 387 301 235 151 ON ON OFF Y 1395 1332 1272 1207 1136 1074 1007 948 Ylo 1223 1144 1081 995 918 839 798 738 OFF ON OFF Y 1025 850 754 670 594 520 443 366 Ylo 1223 1144 1081 995 918 839 798 738 OFF OFF ON Y 1258 1179 1115 1030 954 885 814 776 Ylo 1032 800 578 487 387 301 235 151 OFF ON ON Y 1025 850 754 670 594 520 443 366 Y10 1258 1179 1115 1030 954 885 814 776 ON OFF ON Y 1395 1332 1272 1207 1136 1074 1007 948 Ylo 1258 1179 1115 1030 954 885 814 776 ON ON ON Y 1032 800 578 487 387 301 235 151 *DEFAULT PCBBF139 DC80VE06036* - CONTINOUS FAN DIP SWITCHES S2-2 S2-3 S2-4 STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM G 1025 850 754 670 594 520 443 366 ON OFF OFF G 1258 1179 1115 1030 954 885 814 776 ON ON OFF G 1032 800 578 487 387 301 235 151 OFF ON OFF G 1223 1144 1081 995 918 839 798 738 OFF OFF ON G 1395 1332 1272 1207 1136 1074 1007 948 OFF ON ON G 1025 850 754 670 594 520 443 366 ON OFF ON G 1025 850 754 670 594 520 443 366 ON ON ON G 1025 850 754 670 594 520 443 366 PCBBF139 DC80VE0603B* - HEATING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S1-4 S2-1 TsTAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 1025 30 850 37 754 41 670 46 594 52 520 443 366 OFF OFF* W2 1258 35 1179 38 1115 40 1030 43 954 47 885 814 776 W1 1032 30 800 39 578 54 487 N/A 387 N/A 301 235 151 ON OFF W2 1258 35 1179 38 1115 40 1030 43 954 47 885 814 776 W1 1032 30 800 39 578 54 487 N/A 387 N/A 301 235 151 ON ON W2 1223 36 1144 39 1081 41 995 45 918 48 839 798 738 W1 1223 N/A 1144 N/A 1081 N/A 995 N/A 918 N/A 839 798 738 OFF ON** W2 1395 N/A 1332 N/A 1272 N/A 1207 N/A 1136 N/A 1074 1007 948 *DEFAULT **NOT RECOMMENDED NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For mostjobs, about 400 CFM per ton when coaling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. SS-DM80VE www.daikincomfort.com 15 DCSOVE AIRFLOW DATA (CONT.) PCBBF139 DC80VE0804B* - COOLING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM S1-1 S1-2 S1-3 Ylo 1596 1553 1512 1491 1450 1411 1388 1347 OFF OFF OFF* Y 1757 1713 1691 1664 1625 1588 1552 1522 Ylo 784 716 645 583 516 405 334 282 ON OFF OFF Y 1596 1553 1512 1491 1450 1411 1388 1347 Ylo 784 716 645 583 516 405 334 282 ON ON OFF Y 1757 1713 1691 1664 1625 1588 1552 1522 Ylo 1596 1553 1512 1491 1450 1411 1388 1347 OFF ON OFF Y 1040 973 936 918 859 805 770 720 Ylo 1596 1553 1512 1491 1450 1411 1388 1347 OFF OFF ON Y 1401 1366 1320 1278 1236 1194 1153 1112 Ylo 784 716 645 583 516 405 334 282 OFF ON ON Y 1040 973 936 918 859 805 770 720 Ylo 1401 1366 1320 1278 1236 1194 1153 1112 ON OFF ON Y 1757 1713 1691 1664 1625 1588 1552 1522 Ylo 1401 1366 1320 1278 1236 1194 1153 1112 ON ON ON Y 784 716 645 583 516 405 334 282 *DEFAULT PCBBF139 DC80VE08046* - CONTINOUS FAN DIP SWITCHES S2-2 S2-3 S2-4 STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM G 1040 973 936 918 859 805 770 720 ON OFF OFF G 1401 1366 1320 1278 1236 1194 1153 1112 ON ON OFF G 784 716 645 583 516 405 334 282 OFF ON OFF G 1596 1553 1512 1491 1450 1411 1388 1347 OFF OFF ON G 1757 1713 1691 1664 1625 1588 1552 1522 OFF ON ON G 1040 973 936 918 859 805 770 720 ON OFF ON G 1040 973 936 918 859 805 770 720 ON ON ON G 1040 973 936 918 859 805 770 720 PCBBF139 DC80VE0804B* - HEATING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S1-4 S2-1 TsTAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 1040 40 973 43 936 44 918 45 859 48 805 770 720 OFF OFF* W2 1401 42 1366 43 1320 45 1278 46 1236 48 1194 1153 1112 W1 784 53 716 58 645 N/A 583 N/A 516 N/A 405 334 282 ON OFF W2 1401 42 1366 43 1320 45 1278 46 1236 48 1194 1153 1112 W1 784 53 716 58 645 N/A 583 N/A 516 N/A 405 334 282 ON ON W2 1596 37 1553 38 1512 39 1491 40 1450 41 1411 1388 1347 W1 1596 N/A 1553 N/A 1512 N/A 1491 N/A 1450 N/A 1411 1388 1347 OFF ON** W2 1757 N/A 1713 N/A 1691 N/A 1664 N/A 1625 N/A 1588 1552 1522 *DEFAULT **NOT RECOMMENDED NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For mostjobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. MINIMUM FILTER SIZES Filter Size (in') 1 (1) 16 x 25 (Side or Bottom) 1 (1) 16 x 25 (Side or Bottom)' (2) 16 x 25 (Side) or (1) 20 x 25 (Bottom) Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located. ' Use 2 -16 X 25 filters on side returns or 20 X 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity. 16 www.daikincomfort.com SS-DM80VE DCSOVE AIRFLOW DATA (CONT.) PCBBF139 DC80VE0805C* - COOLING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM S1-1 S1-2 S1-3 Y10 1782 1744 1715 1700 1660 1619 1579 1510 OFF OFF OFF* Y 2145 2089 2058 2036 2020 2000 1971 1935 Ylo 1171 884 667 576 495 399 338 302 ON OFF OFF Y 1782 1744 1715 1700 1660 1619 1579 1510 Y10 1171 884 667 576 495 399 338 302 ON ON OFF Y 2145 2089 2058 2036 2020 2000 1971 1935 Ylo 1782 1744 1715 1700 1660 1619 1579 1510 OFF ON OFF Y 1175 1098 1024 947 883 823 764 703 Ylo 1782 1744 1715 1700 1660 1619 1579 1510 OFF OFF ON Y 1547 1506 1474 1442 1390 1332 1273 1222 Ylo 1171 884 667 576 495 399 338 302 OFF ON ON Y 1175 1098 1024 947 883 823 764 703 Y10 1547 1506 1474 1442 1390 1332 1273 1222 ON OFF ON Y 2145 2089 2058 2036 2020 2000 1971 1935 Ylo 1547 1506 1474 1442 1390 1332 1273 1222 ON ON ON Y 1171 884 667 576 495 399 338 302 *DEFAULT PCBBF139 DC80VE0805C* - CONTINOUS FAN DIP SWITCHES S2-2 S2-3 S2-4 STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM G 1175 1098 1024 947 883 823 764 703 ON OFF OFF G 1547 1506 1474 1442 1390 1332 1273 1222 ON ON OFF G 1171 884 667 576 495 399 338 302 OFF ON OFF G 1782 1744 1715 1700 1660 1619 1579 1510 OFF OFF ON G 2145 2089 2058 2036 2020 2000 1971 1935 OFF ON ON G 1175 1098 1024 947 883 823 764 703 ON OFF ON G 1175 1098 1024 947 883 823 764 703 ON ON ON G 1175 1098 1024 947 883 823 764 703 PCBBF139 DC80VE0805C* - HEATING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S1-4 S2-1 TsTAT CALL CFM RISE CFM RISE CFM RISE I CFM RISE CFM RISE CFM CFM CFM W1 1175 35 1098 38 1024 41 947 44 883 47 823 764 703 OFF OFF* W2 1547 38 1506 39 1474 40 1442 41 1390 43 1332 1273 1222 W1 1171 35 884 47 667 N/A 576 N/A 495 N/A 399 338 302 ON OFF W2 1547 38 1506 39 1474 40 1442 41 1390 43 1332 1273 1222 W1 1171 N/A 884 N/A 667 N/A 576 N/A 495 N/A 399 338 302 ON ON** W2 1782 N/A 1744 N/A 1715 N/A 1700 N/A 1660 N/A 1619 1579 1510 W1 1782 N/A 1744 N/A 1715 N/A 1700 N/A 1660 N/A 1619 1579 1510 OFF ON** W2 2145 N/A 2089 N/A 2058 N/A 2036 N/A 2020 N/A 2000 1971 1935 *DEFAULT **NOT RECOMMENDED NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For mostjobs, about 400 CFM per ton when coaling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. See Notes on page 12. SS-DM80VE www.daikincomfort.com 17 DCSOVE AIRFLOW DATA (CONT.) PCBBF139 D*80VE1005C* - COOLING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM S1-1 S1-2 S1-3 Ylo 1820 1769 1726 1685 1642 1603 1557 1521 OFF OFF OFF* Y 2235 2185 2139 2108 2076 2032 2000 1964 Ylo 803 719 631 540 471 337 298 265 ON OFF OFF Y 1820 1769 1726 1685 1642 1603 1557 1521 Ylo 803 719 631 540 471 337 298 265 ON ON OFF Y 2235 2185 2139 2108 2076 2032 2000 1964 Ylo 1820 1769 1726 1685 1642 1603 1557 1521 OFF ON OFF Y 1626 1574 1524 1479 1433 1410 1400 1358 Ylo 1820 1769 1726 1685 1642 1603 1557 1521 OFF OFF ON Y 2169 2116 2070 2038 2003 1970 1933 1897 Ylo 803 719 631 540 471 337 298 265 OFF ON ON Y 1626 1574 1524 1479 1433 1410 1400 1358 Y10 2169 2116 2070 2038 2003 1970 1933 1897 ON OFF ON Y 2235 2185 2139 2108 2076 2032 2000 1964 Ylo 2169 2116 2070 2038 2003 1970 1933 1897 ON ON ON Y 803 719 631 540 471 337 298 265 *DEFAULT PCBBF139 D*80VE1005C* - CONTINOUS FAN DIP SWITCHES S2-2 S2-3 S2-4 STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 TsTAT CALL CFM CFM CFM CFM CFM CFM CFM CFM G 1626 1574 1524 1479 1433 1410 1400 1358 ON OFF OFF G 2169 2116 2070 2038 2003 1970 1933 1897 ON ON OFF G 803 719 631 540 471 337 298 265 OFF ON OFF G 1820 1769 1726 1685 1642 1603 1557 1521 OFF OFF ON G 2235 2185 2139 2108 2076 2032 2000 1964 OFF ON ON G 1626 1574 1524 1479 1433 1410 1400 1358 ON OFF ON G 1626 1574 1524 1479 1433 1410 1400 1358 ON ON ON G 1626 1574 1524 1479 1433 1410 1400 1358 PCBBF139 D*80VE1005C* - HEATING DIP SWITCHES STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S1-4 S2-1 TsTAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 1626 32 1574 33 1524 34 1479 35 1433 36 1410 1400 1358 OFF OFF* W2 2169 34 2116 35 2070 36 2038 36 2003 37 1970 1933 1897 W1 803 N/A 719 N/A 631 N/A 540 N/A 471 N/A 337 298 265 ON OFF W2 2169 34 2116 35 2070 36 2038 36 2003 37 1970 1933 1897 W1 803 N/A 719 N/A 631 N/A 540 N/A 471 N/A 337 298 265 ON ON W2 1820 41 1769 42 1726 43 1685 44 1642 45 1603 1557 1521 W1 1820 N/A 1769 N/A 1726 N/A 1685 N/A 1642 N/A 1603 1557 1521 OFF ON** W2 2235 N/A 2185 N/A 2139 N/A 2108 N/A 2076 N/A 2032 2000 1964 *DEFAULT **NOT RECOMMENDED NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For mostjobs, about 400 CFM per ton when coaling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 18 www.daikincomfort.com SS-DM80VE V) b 00 00 0 m Q 0 3 0 0 0 3 BTU OUTPUT VS. TEMPERATURE RISE CHART 100 90 80 70 w N_ LU 60 1-1 a w 50 w i- 40 30 20 10 30 40 50 60 70 80 90 100 110 120 130 140 150 OUTPUT BTU/H X 1,000 600 CFM zoo soo 900 1000 1100 1200 i 1400 1600 1800 2000 2200 CFM 400 FORMULAS BTU/h Output = CFM x 1.08 x Rise BTU/H Output Rise = CFM x 1.08 m v m C m m z c) m n 2 � r � —ill GND C r, L.. 1� VAC/1 /60HZ POWERSUPPLV WITH OVERCURRENT ID BLOWER TWO -STAGE PRESSURE 1 HOT SWITCH ASSEMBLY j Z �` L PROTECTION DEVICE C K IGNITER OR HIGH FIREr K r 1 WARNING:DISCONNECT LOW FIRE PRESSURE SWITCH ` POWER BEFORE N SERVICING. WIRING C PRESSURE OOR W TO UNIT MUST BE SWITCH N PROPERLY POLARIZED DISCONNECT 2 CIRCUIT � AND GROUNDED. TO 115VAC/ 1 /60 HZ POWER SUPPLY WITH CONNECTOR HI a PU OVERCURRENT PROTECTION DEVICE FLAME WARNING: L GND i TWO STAGE C 2 GV SENSOR DISCONNECT POWER BEFORE SERVICING. GAS VALVE PM 1 SR WIRING TO UNIT (WHITE RODGERS) MUST BE PROPERLY SOME UNITS MAY HAVE POLARIZED AND DISCONNECT GROUNDED. 1 ROLL OUT SWITCH BL PK�OR D' DOOR (7 SWITCH J AUTO RESET PRIMARY ti JUNCTION Box LIMIT CONTROL PU O ti � INDUCED A GND INDOOR 3 WH DRAFT CIRCULATOR RD BLOWER Z BLWR BK GND BURNER COMPARTMENT GND LINE O NEUTrta - BLOWER COMPARTMENT PU AUTO RESET T. AUXILIARY K 9 HUM OUT �� r K HUMIDIFIER J LI1TfiAL LIMIT CONTROL HUM �_ �. m ELECTRONIC NEIIIi1n , AI`CLEANEF , Q IND HI NEUIHnI D BLWR ND LO NEUTRAL O BK RD HOTS IGNITER BL � D r-s BK FLAME SENSOR LINE 115 VAC NEUTRAL OR 1 A N x O iv ca a 3 OI O; A 30 UTRAL 40 VA FUSE3A TH 5 TRANSFORMER O O O a 29 R "VAC PRIMARY O Ol O ❑ ❑ ❑ AUTO RESET I TO LIMIT CONTROL I _ 2 HL < V1 O 1t �� AUTO RESET AUXILIARY LIMIT I a CONTROLS O PS1 (12) C �51 0� NO S2 LOW FIRE PRESS Z W2 m PS2(2) NO SWITCH TO C V2 MC R i HIGH FIRE /�I� ROLLOUT PRESS. SWTICH MAMIT Z MGV lrr�� LIMIT CONTROLS CONTRO BR m O HLI (8) ®DIAGNOSTIC y EHUM I MVL(J) Q LED'S PD T Q PM YL 1, PK �_ I MVH (1) C L BR C MVC(8) OR HI YLO V W1 W2 R G C TWIN GND (4) GAS TR I, GN�7 VALVE N.E.C. CLASS 2 WIRE A TO O FUSE <N <� ECM MTR 0 m BK z INDOOR H HARNESS II BE O To MICRO CIRCULATOR BLWR GND 3 W �$ G C+N g� BK INTEGRATED CONTROL MODULE BK BK � O = I NOTES: 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT AMPS. C D GND a 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. BLOWER CIRCULATOR BLOWER COMPARTMENT DOOR SWITCH 3. IF ANY OF THE ORIGINAL W IRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL (OPENWHEN HAVING ATEMPERATURE RATING OF AT LEAST 105°C. USE COPPER CONDUCTORS ONLY. DOOR OPEN) 4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. 5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY 11 NO THERMOSTAT INPUTS) RED LED FLASH CODE Y ON = INTERNAL GV ERROR, MICRO AND FREQUENCY CHECK LED FLASH CODE COLOR CODES: I EQUIPMENTGND rh yA.M�BER RAPID =TWINNINGERROR Lvr RAPID = LOW FLAME SENSE CURRENT PK PINK FIELD GND 1 ISTEAD 1FLASH= FLAME SENSEDWHEN NO FLAME SHOULD BE PRESENT }�•Tyt1FLASH= NORMAL OPERATION WITH CALL FOR BR BROWN 2 FLASHES =PRESSURE SWITCH STUCKCLOSED/INDUCER ERROR 1ST STAGE WH WHITE FIELD SPLICE EHEAT ION 2 FLASHES - NORMAL OPERATION WITH 3 FLASHES =1ST STAGE PRESSURE SWITCH STUCK BL BLUE SWITCH (TEMP.) FOR OPENANDUCER ERROR ��,,yy CALL FOR 2ND STAGE HEAT GV GRAY r0 3 FLASHES= W2 PRESENT WITH NO W1 RD RED IGNITER 4 FLASHES =OPEN LIMIT SWITCH q 4FLASHES = Y PRESENT WITH NOGCALL, YLO YL YELLOW SWITCH (PRESS.) 5 FLASHES =OPEN ROLLOUT/OPEN FUSE DETECTED PRESENT WITH NO G CALL OR ORANGE QVERCURRENT 6 FLASHES = PRESSURE SWITCH CYCLE LOCKOUT GREEN LED FLASH CODE PU PURPLE EEEI PROT. DEVICE FLASHES =EXTERNAL LOCKOUT (RETRIES) ON =STANDBY 8 8FLASHES = EXTERNAL LOCKOUT (RECYCLES) GN GREEN BK BLACKTERMINAL JUNCTION TSTEADY RAPID = NORMAL OPERATION WITH CALL FOR FAN (G) INTERNAL TO S FLASHES +GROUNDING OR REVERSED POLARITY 1 FLASH = NORMAL OPERATION WITH CALL FOR —_ INTEGRATED CONTROL 10 FLASHES = GAS FLOW WITH NO CALL FOR HEAT LOW STAGE COOL (YLO+G) PLUG CONNECTION 11 FLASHES = LIMIT SWITCH OPEN -BLOWER FAILURE *, 2 FLASHES = NORMAL OPERATION W ITH CALL FOR HIGH LOW VOLTAGE(24V) STAGE COOUOR SINGLE STAGE COOLING(V+G) 12 FLASHES=IGNITOR RELAY FAILURE LOW VOLTAGE FIELD— — 3 DOUBLE FLASHES = 2ND STAGE PRESSURE SWITCH HI VOLTAGE (115V) STUCK OPEWINDUCER ERROR 0140F02480-A HI VOLTAGE FIELD u 20 www.daikincomfort.com SS-DM80VE ACCESSORIES MODEL LPM-06 LP Conversion Kit (Springs & Orifice)' AFE18-60A Fossil Fuel Kit (must be used in a dual -fuel application with a compatible thermostat) ASAS Electronic Air Cleaners (sizes = -10, -11, -12 or -18) AMU Media Air Cleaners (sizes = 1620, 2020, 1625 or 2025) ' White -Rodgers and Honeywell valves NOTE: Twinning kit is not required, but the furnace is capable of twinning. See details in the unit 10 manual. SS-DM80VE www.daikincomfort.com 21 NOTES 22 www.daikincomfort.com SS-DM80VE NOTES SS-DM80VE www.daikincomfort.com 23 NOTES Our continuing commitment to quality products may mean a change in specifications without notice. ©2021 DA/K/NMANUFACTURING COMPANY. L.P. • Houston, Texas • Printed in the USA. 24 www.daikincomfort.com SS-DM80VE