Loading...
BLD2022-0508_Manufacturer_Specifications_and_Installation_Instructions_4.20.2022_8.36.20_PM_2817394r DA/K/N UP To 16 SEER 1'2 To 5 TONS ■ Standard Features • High -efficiency Copeland® scroll compressor • High -density foam compressor sound blanket • Advanced Copeland® CoreSenseTm Technology • Single -speed PSC condenser fan motor • Factory -installed filter drier • Copper tube / enhanced aluminum fin coil • Sweat connection service valves with easy access to gauge ports • AHRI Certified; ETL Listed Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR® criteria. Ask your contractor for details or visit www.energystacgov. DX16SA HIGH -EFFICIENCY SPLIT SYSTEM AIR CONDITIONER Contents Nomenclature ........................................ 2 Product Specifications ........................... 3 Expanded Cooling Data ......................... 4 AHRI Ratings (see note) ....................... 24 Dimensions .......................................... 25 Wiring Diagrams ................................. 26 Accessories .......................................... 28 ■ Cabinet Features • Heavy -gauge galvanized steel cabinet with grille -style sound control top • Custom Nickel Gray powder -paint finish • 500-hour salt -spray tested • Wire fan discharge grille • Steel louver coil guard • Rust -resistant coated screws • Top and side maintenance access • Single -panel access to controls with space pro- vided for field -installed accessories • When properly anchored, meets the 2017 Florida Building Code unit integrity requirements for hurri- cane -type winds (Anchor bracket kits available.) ETA US Ilsosam Intertek "— * Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 6-Year Unit Replacement Limited Warranty and 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Additional requirements for annual maintenance are required for the Unit Replacement Limited Warranty. Online registration and some of the additional requirements are not required in California or Quebec. SS-DX16SA www.daikincomfort.com 12/19 Supersedes 11/19 NOMENCLATURE D X 16 S A 036 3 AA 1 2 3,4 5 6 7,8,9 10 11,12 Brand Engineering* D - Daikin Major & Minor revisions Not used for inventory control. Type Voltage X - AC R-410A 1- 208/230 V Single -Phase 60 Hz Z - H P R-410A Nominal Tonnage SEER 018 - 1% tons 031- 2% tons 048 - 4 tons 14 - 14 SEER 18 - 18 SEER 024 - 2 tons 036 - 3 tons 060 - 5 tons 16 - 16 SEER 20 - 20 SEER 030 - 2Y2 tons 037 - 3 tons 061- 5 tons 042 - 3% tons (high capacity) Compressor Feature Set S - Single Stage A - Base D - Deluxe T - Two Stage C - Communicating N - Nominal 2 www.daikincomfort.com SS-DX16SA PRODUCT SPECIFICATIONS 1 1 . 1 . CAPACITIES Nominal Cooling (BTU/h) 18,000 23,600 29,000 30,000 34,800 36,000 42,000 45,500 54,000 57,000 Decibels 71.5 71.5 71.5 71.5 71.5 73 73 73 73 73 COMPRESSOR RLA 9.0 13.5 12.8 12.8 14.1 15.4 17.9 17.9 21.4 25 LRA 46 58.3 64 64 77 83.9 112 112 135 134 CONDENSER FAN MOTOR Horsepower 1/6 1/6 1/6 1/6 1/6 1/6 1/6 1/4 1/3 1/4 FLA 0.95 0.95 0.95 0.95 0.95 0.95 0.95 1.30 2.80 1.30 REFRIGERATION SYSTEM Refrigerant Line Size Liquid Line Size ("O.D.) %" %" W, %" %" %" %" %" %" %" Suction Line Size 'O.D. %" W,%" �u ' 3/V V Y" 3/8" �" 3/8" Refrigerant Connection Size Liquid Valve Size ("O.D.) %" %" W, W, %" %" %" %" W, W Suction Valve Size ("O.D.) 3/" '/" %" %" %" %" %" %" %" %" Valve Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Refrigerant Charge (oz.) 78 70 78 94 94 93 110 121 237 125 ELECTRICAL DATA Voltage / Phase (60 Hz) 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 Minimum Circuit Ampacity z 12.2 17.8 17.0 17.0 18.6 20.2 23.3 23.7 28.3 32.6 Max. Overcurrent Protections 20 30 25 25 30 35 40 40 50 50 Min/ Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253 Electrical Conduit Size %" or W %" or W %" or W %" or %" %" or W %" or W %" or W %" or W %" or W %" or W EQUIPMENT WEIGHT (LBS) 145 142 149 161 162 182 206 219 279 291 SHIP WEIGHT (LBS) 163 160 167 179 180 204 228 241 301 314 ENERGY STAR® CERTIFIED ^ I m 11A T, rai M I m [ NO ^ ENERGY STAR NOTES • Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov. • The www.energystar.gov website provides up-to-date system combinations certified to meet ENERGY STAR requirements. See Page 24 for all ENERGY STAR certified combinations as of this document's revision date. Tested and rated in accordance with AHRI Standard 210/240 Z Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes a Must use time -delay fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. • Installer will need to supply Y8" to 1%" adapters for suction line connections. • Unit is charged with refrigerant for 15' of W liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL. SS-DX16SA www.daikincomfort.com OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F D: ENTERING INDOOR WET BULB TEMPERATURE MBh 15.8 16.4 17.9 - 15.4 16.0 17.5 - 15.1 15.6 17.1 - 14.7 15.2 16.7 - 14.0 14.5 15.9 - 12.9 13.4 14.7 - S/T 0.66 0.55 0.38 0.69 0.57 0.40 0.70 0.59 0.41 0.73 0.61 0.42 0.75 0.63 0.44 0.76 0.64 0.44 AT 18 16 12 19 16 12 19 16 12 19 16 12 18 16 12 17 15 11 525 kW 1.18 1.20 1.23 1.26 1.28 1.31 1.32 1.35 1.38 1.38 1.41 1.45 1.43 1.46 1.50 1.47 1.50 1.54 Amps 4.3 4.3 4.5 4.6 4.7 4.8 4.9 5.0 5.2 5.2 5.4 5.5 5.6 5.7 5.9 5.9 6.0 6.2 HiPR 198 213 225 222 239 252 253 272 287 288 310 327 324 348 368 358 385 406 Lo PR 102 109 119 108 115 125 112 119 130 118 125 137 124 131 144 128 136 148 MBh 17.1 17.7 19.4 16.7 17.3 19.0 16.3 16.9 18.5 15.9 16.5 18.1 15.1 15.7 17.2 14.0 14.5 15.9 S/T 0.69 0.57 0.40 0.71 0.59 0.41 0.73 0.61 0.42 0.75 0.63 0.44 0.78 0.65 0.45 0.79 0.66 0.46 AT 17 14 11 17 15 11 17 15 11 17 15 11 17 14 11 16 14 10 70 650 kW 1.21 1.23 1.26 1.28 1.31 1.34 1.35 1.38 1.41 1.41 1.44 1.48 1.46 1.49 1.53 1.51 1.54 1.58 Amps 4.4 4.5 4.6 4.7 4.8 4.9 5.1 5.2 5.3 5.4 5.5 5.7 5.7 5.8 6.0 6.0 6.2 6.4 HiPR 204 220 232 229 246 260 260 280 296 297 319 337 334 359 379 369 397 419 Lo PR 105 112 122 111 118 129 116 123 134 122 129 141 127 136 148 132 140 153 MBh 17.1 17.7 19.4 16.7 17.3 19.0 16.3 16.9 18.5 15.9 16.5 18.1 15.1 15.7 17.2 14.0 14.5 15.9 S/T 0.69 0.57 0.40 0.71 0.59 0.41 0.73 0.61 0.42 0.75 0.63 0.44 0.78 0.65 0.45 0.79 0.66 0.46 AT 16 14 11 16 14 11 16 14 11 16 14 11 16 14 11 15 13 10 675 kW 1.21 1.23 1.26 1.28 1.31 1.34 1.35 1.38 1.41 1.41 1.44 1.48 1.46 1.49 1.53 1.51 1.54 1.58 Amps 4.4 4.5 4.6 4.7 4.8 4.9 5.1 5.2 5.3 5.4 5.5 5.7 5.7 5.8 6.0 6.0 6.2 6.4 HiPR 204 220 232 229 246 260 260 280 296 297 319 337 334 359 379 369 397 419 Lo PR 1 105 112 122 111 118 129 116 123 134 122 129 141 127 136 148 132 140 153 MBh 16.1 16.5 17.9 19.2 15.7 16.2 17.5 18.8 15.3 15.8 17.1 18.3 15.0 15.4 16.7 17.9 14.2 14.6 15.8 17.0 13.2 13.5 14.7 15.7 S/T 0.75 0.67 0.51 0.33 0.78 0.70 0.53 0.34 0.80 0.72 0.54 0.35 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.86 0.77 0.59 0.38 AT 21 20 16 11 21 20 16 11 21 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10 525 kW 1.19 1.21 1.24 1.28 1.27 1.29 1.32 1.36 1.33 1.36 1.39 1.43 1.39 1.42 1.46 1.50 1.44 1.47 1.51 1.55 1.48 1.51 1.56 1.60 Amps 4.3 4.4 4.5 4.7 4.6 4.7 4.9 5.0 5.0 5.1 5.2 5.4 5.3 5.4 5.6 5.8 5.6 5.7 5.9 6.1 5.9 6.1 6.3 6.5 HiPR 200 215 227 237 224 242 255 266 255 275 290 303 291 313 330 345 327 352 372 388 361 389 411 428 Lo PR 103 110 120 128 109 116 127 135 113 121 132 140 119 127 138 147 125 133 145 154 129 137 150 160 MBh 17.4 17.9 19.4 20.8 17.0 17.5 19.0 20.3 16.6 17.1 18.5 19.9 16.2 16.7 18.1 19.4 15.4 15.8 17.2 18.4 14.3 14.7 15.9 17.1 S/T 0.78 0.70 0.53 0.34 0.81 0.72 0.55 0.35 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.89 0.80 0.60 0.39 0.90 0.80 0.61 0.39 AT 19 18 15 10 19 18 15 10 19 18 15 10 20 18 15 10 19 18 15 10 18 17 14 9 75 650 kW 1.21 1.24 1.27 1.30 1.29 1.32 1.35 1.39 1.36 1.39 1.42 1.46 1.42 1.45 1.49 1.53 1.47 1.50 1.54 1.59 1.52 1.55 1.59 1.64 Amps 4.4 4.5 4.6 4.8 4.7 4.8 5.0 5.2 5.1 5.2 5.4 5.6 5.4 5.6 5.7 5.9 5.8 5.9 6.1 6.3 6.1 6.2 6.4 6.7 HiPR 206 222 234 244 231 249 263 274 263 283 299 312 300 323 341 355 337 363 383 400 373 401 423 442 Lo PR 106 113 124 132 113 120 131 139 117 124 136 145 123 131 143 152 129 137 150 159 133 142 155 165 MBh 17.4 17.9 19.4 20.8 17.0 17.5 19.0 20.3 16.6 17.1 18.5 19.9 16.2 16.7 18.1 19.4 15.4 15.8 17.2 18.4 14.3 14.7 15.9 17.1 S/T 0.78 0.70 0.53 0.34 0.81 0.72 0.55 0.35 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.89 0.80 0.60 0.39 0.90 0.80 0.61 0.39 AT 19 17 14 10 19 17 14 10 19 17 14 10 19 17 14 10 19 17 14 10 17 16 13 9 675 kW 1.21 1.24 1.27 1.30 1.29 1.32 1.35 1.39 1.36 1.39 1.42 1.46 1.42 1.45 1.49 1.53 1.47 1.50 1.54 1.59 1.52 1.55 1.59 1.64 Amps 4.4 4.5 4.6 4.8 4.7 4.8 5.0 5.2 5.1 5.2 5.4 5.6 5.4 5.6 5.7 5.9 5.8 5.9 6.1 6.3 6.1 6.2 6.4 6.7 HiPR 206 222 234 244 231 249 263 274 263 283 299 312 300 323 341 355 337 363 383 400 373 401 423 442 Lo PR 106 113 124 132 113 120 131 139 117 124 136 145 123 131 143 152 129 137 150 159 133 142 155 165 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) High and low pressures are measured at the liquid and suction service valves. kW = Total system power k V N 0) Ln IN O N 00 N Q 0 3 0 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 16.4 16.7 17.9 19.1 16.0 16.3 17.4 18.6 15.6 15.9 17.0 18.2 15.2 15.6 16.6 17.8 14.5 14.8 15.8 16.9 13.4 13.7 14.6 15.6 S/T 0.83 0.77 0.63 0.47 0.86 0.80 0.65 0.49 0.88 0.82 0.67 0.50 0.91 0.85 0.69 0.52 0.94 0.88 0.72 0.54 0.95 0.89 0.72 0.54 AT 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 21 19 15 525 kW 1.20 1.22 1.25 1.28 1.27 1.30 1.33 1.37 1.34 1.37 1.40 1.44 1.40 1.43 1.47 1.51 1.45 1.48 1.52 1.57 1.49 1.52 1.57 1.61 Amps 4.3 4.4 4.6 4.7 4.6 4.7 4.9 5.1 5.0 5.1 5.3 5.5 5.3 5.5 5.6 5.8 5.7 5.8 6.0 6.2 6.0 6.1 6.3 6.5 Hi PR 202 217 230 239 227 244 258 269 258 277 293 306 294 316 334 348 330 355 375 392 365 393 415 433 Lo PR 104 111 121 129 110 117 128 136 115 122 133 142 120 128 140 149 126 134 146 156 130 139 152 161 MBh 17.7 18.1 19.4 20.7 17.3 17.7 18.9 20.2 16.9 17.3 18.5 19.7 16.5 16.8 18.0 19.2 15.7 16.0 17.1 18.3 14.5 14.8 15.8 16.9 S/T 0.86 0.80 0.65 0.49 0.89 0.83 0.68 0.51 0.91 0.85 0.69 0.52 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.56 0.98 0.92 0.75 0.56 AT 21 21 18 14 22 21 18 14 22 21 18 14 22 21 18 15 22 21 18 14 20 19 17 13 80 650 kW 1.22 1.24 1.28 1.31 1.30 1.32 1.36 1.40 1.37 1.40 1.43 1.48 1.43 1.46 1.50 1.54 1.48 1.51 1.56 1.60 1.53 1.56 1.60 1.65 Amps 4.4 4.5 4.7 4.8 4.8 4.9 5.0 5.2 5.1 5.3 5.4 5.6 5.5 5.6 5.8 6.0 5.8 5.9 6.1 6.4 6.1 6.3 6.5 6.7 Hi PR 208 224 237 247 234 251 266 277 266 286 302 315 303 326 344 359 341 366 387 404 376 405 428 446 Lo PR 108 114 125 133 114 121 132 141 118 126 137 146 124 132 144 153 130 138 151 161 134 143 156 166 MBh 17.7 18.1 19.4 20.7 17.3 17.7 18.9 20.2 16.9 17.3 18.5 19.7 16.5 16.8 18.0 19.2 15.7 16.0 17.1 18.3 14.5 14.8 15.8 16.9 S/T 0.86 0.80 0.65 0.49 0.89 0.83 0.68 0.51 0.91 0.85 0.69 0.52 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.56 0.98 0.92 0.75 0.56 AT 21 20 17 14 21 20 17 14 21 20 17 14 21 20 18 14 21 20 17 14 19 19 16 13 675 kW 1.22 1.24 1.28 1.31 1.30 1.32 1.36 1.40 1.37 1.40 1.43 1.48 1.43 1.46 1.50 1.54 1.48 1.51 1.56 1.60 1.53 1.56 1.60 1.65 Amps 4.4 4.5 4.7 4.8 4.8 4.9 5.0 5.2 5.1 5.3 5.4 5.6 5.5 5.6 5.8 6.0 5.8 5.9 6.1 6.4 6.1 6.3 6.5 6.7 Hi PR 208 224 237 247 234 251 266 277 266 286 302 315 303 326 344 359 341 366 387 404 376 405 428 446 Lo PR 108 114 125 133 114 121 132 141 118 126 137 146 124 132 144 153 130 138 151 161 134 143 156 166 MBh 16.6 17.0 17.8 19.0 16.3 16.6 17.4 18.5 15.9 16.2 16.9 18.1 15.5 15.8 16.5 17.6 14.7 15.0 15.7 16.8 13.6 13.9 14.5 15.5 S/T 0.87 0.84 0.75 0.61 0.90 0.87 0.78 0.63 0.92 0.89 0.80 0.65 0.95 0.92 0.83 0.67 0.99 0.95 0.86 0.70 0.99 0.96 0.87 0.70 AT 25 25 23 20 26 25 24 21 26 25 24 21 26 25 24 21 25 25 24 20 24 23 22 19 525 kW 1.21 1.23 1.26 1.29 1.28 1.31 1.34 1.38 1.35 1.38 1.41 1.45 1.41 1.44 1.48 1.52 1.46 1.49 1.53 1.58 1.51 1.53 1.58 1.63 Amps 4.4 4.5 4.6 4.7 4.7 4.8 4.9 5.1 5.1 5.2 5.3 5.5 5.4 5.5 5.7 5.9 5.7 5.8 6.0 6.2 6.0 6.2 6.4 6.6 Hi PR 204 220 232 242 229 246 260 271 260 280 296 309 297 319 337 352 334 359 379 395 369 397 419 437 Lo PR 105 112 122 130 111 118 129 138 116 123 134 143 122 129 141 150 127 136 148 158 132 140 153 163 MBh 18.0 18.4 19.3 20.5 17.6 18.0 18.8 20.1 17.2 17.5 18.4 19.6 16.8 17.1 17.9 19.1 15.9 16.2 17.0 18.2 14.8 15.0 15.8 16.8 S/T 0.90 0.87 0.78 0.63 0.93 0.90 0.81 0.66 0.95 0.92 0.83 0.67 0.98 0.95 0.86 0.70 1.00 0.99 0.89 0.72 1.00 0.99 0.90 0.73 AT 23 23 21 18 23 23 22 19 23 23 22 19 23 23 22 19 23 23 21 19 21 21 20 17 85 650 kW 1.23 1.25 1.29 1.32 1.31 1.33 1.37 1.41 1.38 1.41 1.44 1.49 1.44 1.47 1.51 1.55 1.49 1.52 1.57 1.61 1.54 1.57 1.62 1.66 Amps 4.5 4.6 4.7 4.9 4.8 4.9 5.1 5.2 5.2 5.3 5.5 5.7 5.5 5.7 5.8 6.0 5.9 6.0 6.2 6.4 6.2 6.3 6.5 6.8 Hi PR 210 226 239 249 236 254 268 280 268 289 305 318 306 329 347 362 344 370 391 408 380 409 432 450 Lo PR 109 116 126 134 115 122 133 142 119 127 139 148 125 133 146 155 131 140 153 162 136 145 158 168 MBh 18.0 18.4 19.3 20.5 17.6 18.0 18.8 20.1 17.2 17.5 18.4 19.6 16.8 17.1 17.9 19.1 15.9 16.2 17.0 18.2 14.8 15.0 15.8 16.8 S/T 0.90 0.87 0.78 0.63 0.93 0.90 0.81 0.66 0.95 0.92 0.83 0.67 0.98 0.95 0.86 0.70 1.00 0.99 0.89 0.72 1.00 0.99 0.90 0.73 AT 22 22 20 18 22 22 21 18 22 22 21 18 23 22 21 18 22 22 21 18 20 20 19 17 675 kW 1.23 1.25 1.29 1.32 1.31 1.33 1.37 1.41 1.38 1.41 1.44 1.49 1.44 1.47 1.51 1.55 1.49 1.52 1.57 1.61 1.54 1.57 1.62 1.66 Amps 4.5 4.6 4.7 4.9 4.8 4.9 5.1 5.2 5.2 5.3 5.5 5.7 5.5 5.7 5.8 6.0 5.9 6.0 6.2 6.4 6.2 6.3 6.5 6.8 Hi PR 210 226 239 249 236 254 268 280 268 289 305 318 306 329 347 362 344 370 391 408 380 409 432 450 Lo PR 109 116 126 134 115 122 133 142 119 127 139 148 125 133 146 155 131 140 153 162 136 145 158 168 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k z 0 rn 0 n O O r- z G1 ZD OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E F 952F 1052F 1152F D: ENTERING INDOOR WET BULB TEMPERATURE MBh 22.1 22.9 25.1 - 21.6 22.4 24.5 - 21.1 21.9 23.9 - 20.6 21.3 23.4 - 19.5 20.3 22.2 - 18.1 18.8 20.6 - S/T 0.68 0.57 0.39 0.70 0.59 0.41 0.72 0.60 0.42 0.75 0.62 0.43 0.77 0.65 0.45 0.78 0.65 0.45 AT 20 17 13 20 17 13 20 17 13 20 17 13 20 17 13 19 16 12 700 kW 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.97 1.96 1.97 1.97 1.97 1.97 1.97 Amps 7.6 7.6 7.6 7.6 7.6 7.6 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.8 7.8 7.8 7.8 HiPR 205 221 233 230 248 262 262 282 298 298 321 339 336 361 381 371 399 421 Lo PR 102 109 119 108 115 126 112 120 131 118 126 137 124 132 144 128 136 149 MBh 22.5 23.3 25.5 21.9 22.7 24.9 21.4 22.2 24.3 20.9 21.6 23.7 19.8 20.6 22.5 18.4 19.1 20.9 S/T 0.71 0.59 0.41 0.73 0.61 0.42 0.75 0.63 0.43 0.77 0.65 0.45 0.80 0.67 0.46 0.81 0.68 0.47 AT 19 17 13 20 17 13 20 17 13 20 17 13 20 17 13 18 16 12 70 750 kW 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.97 1.97 1.97 1.97 1.97 1.97 1.97 Amps 7.6 7.6 7.6 7.6 7.6 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.8 7.8 7.8 7.8 7.8 HiPR 209 225 237 234 252 266 266 287 303 303 326 345 341 367 388 377 406 429 Lo PR 104 111 121 110 117 128 114 122 133 120 128 140 126 134 146 130 139 151 MBh 23.2 24.1 26.4 22.7 23.5 25.8 22.2 23.0 25.2 21.6 22.4 24.5 20.5 21.3 23.3 19.0 19.7 21.6 S/T 0.75 0.63 0.43 0.78 0.65 0.45 0.80 0.67 0.46 0.82 0.69 0.48 0.85 0.71 0.49 0.86 0.72 0.50 AT 18 15 12 18 16 12 18 16 12 18 16 12 18 15 12 17 14 11 900 kW 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 Amps 7.6 7.6 7.6 7.6 7.6 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.8 7.8 7.8 7.8 7.8 HiPR 213 229 242 239 257 271 272 292 309 309 333 352 348 375 396 385 414 437 Lo PR 106 113 123 112 119 130 117 124 136 123 130 142 128 137 149 133 141 154 MBh 22.5 23.2 25.1 26.9 22.0 22.6 24.5 26.3 21.4 22.1 23.9 25.6 20.9 21.5 23.3 25.0 19.9 20.5 22.1 23.8 18.4 19.0 20.5 22.0 S/T 0.77 0.69 0.52 0.34 0.80 0.72 0.54 0.35 0.82 0.73 0.56 0.36 0.85 0.76 0.57 0.37 0.88 0.79 0.60 0.38 0.89 0.79 0.60 0.39 AT 23 21 17 12 23 21 17 12 23 21 17 12 23 21 18 12 23 21 17 12 21 20 16 11 700 kW 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 Amps 7.6 7.6 7.6 7.6 7.6 7.6 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.8 7.7 7.7 7.8 7.8 7.8 7.8 7.8 7.8 HiPR 207 223 236 246 233 250 264 276 265 285 301 314 301 324 342 357 339 365 385 402 374 403 426 444 Lo PR 103 110 120 128 109 116 127 135 114 121 132 141 119 127 139 148 125 133 145 155 129 138 150 160 MBh 22.8 23.5 25.4 27.3 22.3 23.0 24.9 26.7 21.8 22.4 24.3 26.0 21.2 21.9 23.7 25.4 20.2 20.8 22.5 24.1 18.7 19.2 20.8 22.4 S/T 0.80 0.72 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.38 0.91 0.82 0.62 0.40 0.92 0.82 0.62 0.40 AT 22 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 21 19 16 11 75 750 kW 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.97 1.96 1.96 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 Amps 7.6 7.6 7.6 7.6 7.6 7.6 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.8 7.7 7.8 7.8 7.8 7.8 7.8 7.8 7.8 HiPR 211 227 240 250 237 255 269 280 269 290 306 319 306 330 348 363 345 371 392 409 381 410 433 452 Lo PR 105 112 122 130 111 118 129 138 116 123 134 143 121 129 141 150 127 135 148 157 132 140 153 163 MBh 23.6 24.3 26.3 28.3 23.1 23.8 25.7 27.6 22.5 23.2 25.1 27.0 22.0 22.6 24.5 26.3 20.9 21.5 23.3 25.0 19.3 19.9 21.6 23.1 S/T 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.38 0.91 0.81 0.61 0.39 0.93 0.84 0.63 0.41 0.97 0.87 0.66 0.42 0.98 0.87 0.66 0.43 AT 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 19 18 15 10 900 kW 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.97 1.96 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 Amps 7.6 7.6 7.6 7.6 7.6 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.9 Hi PR 215 231 244 255 241 260 274 286 274 295 312 325 313 336 355 371 352 378 400 417 389 418 442 461 Lo PR 107 114 125 133 113 121 132 140 118 125 137 146 124 132 144 153 130 138 151 160 134 143 156 166 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (NA) conditions Amps = outdoor unit amps (comp.+fan) High and low pressures are measured at the liquid and suction service valves. kW = Total system power k V N `T Ln IN O N .p N Q 0 3 0 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 75OF 85°F I 959F 1052F 1152F D: ENTERING INDOOR WET BULB TEMPERATURE MBh 22.9 23.4 25.0 26.7 22.4 22.8 24.4 26.1 21.8 22.3 23.8 25.5 21.3 21.8 23.2 24.8 20.2 20.7 22.1 23.6 18.7 19.1 20.5 21.9 S/T 0.85 0.80 0.65 0.48 0.88 0.82 0.67 0.50 0.90 0.84 0.69 0.51 0.93 0.87 0.71 0.53 0.97 0.91 0.74 0.55 0.97 0.91 0.74 0.56 AT 25 24 21 17 26 25 21 17 26 25 22 17 26 25 22 17 26 25 21 17 24 23 20 16 700 kW 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.97 1.96 1.96 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 Amps 7.6 7.6 7.6 7.6 7.6 7.6 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.8 7.7 7.8 7.8 7.8 7.8 7.8 7.8 7.8 Hi PR 209 225 238 248 235 253 267 278 267 288 304 317 304 327 346 361 342 368 389 406 378 407 430 448 Lo PR 104 111 121 129 110 117 128 137 115 122 133 142 121 128 140 149 126 134 147 156 131 139 152 162 MBh 23.2 23.7 25.4 27.1 22.7 23.2 24.8 26.5 22.2 22.6 24.2 25.9 21.6 22.1 23.6 25.2 20.5 21.0 22.4 24.0 19.0 19.4 20.8 22.2 S/T 0.88 0.82 0.67 0.50 0.91 0.85 0.70 0.52 0.93 0.88 0.71 0.53 0.96 0.90 0.74 0.55 1.00 0.94 0.76 0.57 1.00 0.95 0.77 0.58 AT 25 24 21 17 25 24 21 17 25 24 21 17 26 24 21 17 25 24 21 17 23 23 20 16 80 750 kW 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.97 1.96 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 Amps 7.6 7.6 7.6 7.6 7.6 7.6 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.8 7.7 7.8 7.8 7.8 7.8 7.8 7.8 7.8 Hi PR 213 229 242 252 239 257 272 283 272 293 309 322 310 333 352 367 348 375 396 413 385 414 437 456 Lo PR 106 113 123 131 112 119 130 139 117 124 136 144 123 130 142 152 128 137 149 159 133 141 154 164 MBh 24.1 24.6 26.3 28.1 23.5 24.0 25.6 27.4 22.9 23.4 25.0 26.8 22.4 22.9 24.4 26.1 21.3 21.7 23.2 24.8 19.7 20.1 21.5 23.0 S/T 0.93 0.88 0.71 0.53 1.00 0.91 0.74 0.55 1.00 0.93 0.76 0.57 1.00 0.96 0.78 0.58 1.00 1.00 0.81 0.61 1.00 1.00 0.82 0.61 AT 23 22 19 15 24 22 19 15 23 22 19 15 23 22 20 16 22 22 19 15 20 21 18 14 900 kW 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.97 1.97 1.96 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 Amps 7.6 7.6 7.6 7.7 7.6 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.9 Hi PR 217 234 247 257 244 262 277 289 277 298 315 329 316 340 359 374 355 382 404 421 393 422 446 465 Lo PR 108 115 126 134 115 122 133 142 119 127 138 147 125 133 145 155 131 139 152 162 136 144 157 168 MBh 23.3 23.7 24.9 26.5 22.7 23.2 24.3 25.9 22.2 22.6 23.7 25.3 21.7 22.1 23.1 24.7 20.6 21.0 22.0 23.4 19.1 19.4 20.4 21.7 S/T 0.89 0.86 0.77 0.63 0.92 0.89 0.80 0.65 0.94 0.91 0.82 0.67 0.97 0.94 0.85 0.69 1.00 0.98 0.88 0.71 1.00 0.98 0.89 0.72 AT 27 27 25 22 28 27 26 22 28 27 26 22 28 27 26 22 27 27 25 22 25 25 24 21 700 kW 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.97 1.96 1.96 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 Amps 7.6 7.6 7.6 7.6 7.6 7.6 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.8 7.7 7.8 7.8 7.8 7.8 7.8 7.8 7.8 Hi PR 211 228 240 251 237 255 270 281 270 290 307 320 307 331 349 364 346 372 393 410 382 411 434 453 Lo PR 106 112 123 131 112 119 130 138 116 123 135 143 122 130 141 151 128 136 148 158 132 140 153 163 MBh 23.6 24.1 25.2 26.9 23.1 23.5 24.7 26.3 22.5 23.0 24.1 25.7 22.0 22.4 23.5 25.1 20.9 21.3 22.3 23.8 19.4 19.7 20.7 22.0 S/T 0.92 0.89 0.80 0.65 0.95 0.92 0.83 0.67 0.98 0.94 0.85 0.69 1.00 0.98 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.92 0.75 AT 27 26 25 21 27 27 25 22 27 27 25 22 27 27 25 22 26 26 25 22 24 24 23 20 85 750 kW 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.97 1.96 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 Amps 7.6 7.6 7.6 7.6 7.6 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.9 Hi PR 215 232 244 255 241 260 274 286 275 295 312 325 313 336 355 371 352 379 400 417 389 418 442 461 Lo PR 107 114 125 133 113 121 132 140 118 125 137 146 124 132 144 153 130 138 151 161 134 143 156 166 MBh 24.5 24.9 26.1 27.9 23.9 24.4 25.5 27.2 23.3 23.8 24.9 26.6 22.8 23.2 24.3 25.9 21.6 22.0 23.1 24.6 20.0 20.4 21.4 22.8 S/T 0.98 0.94 0.85 0.69 1.00 0.98 0.88 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.97 0.79 1.00 1.00 0.98 0.79 AT 24 24 23 20 24 24 23 20 24 24 23 20 23 24 23 20 22 23 23 20 20 21 21 19 900 kW 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.96 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 1.97 Amps 7.6 7.6 7.6 7.7 7.6 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.9 Hi PR 219 236 249 260 246 265 280 292 280 301 318 332 319 343 362 378 359 386 408 425 396 427 450 470 Lo PR 110 117 127 135 116 123 134 143 120 128 140 149 126 134 147 156 132 141 154 164 137 146 159 169 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k n z m n O O r- z G1 n E OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F •: ENTERING INDOOR WET BULB TEMPERATURE MBh 25.5 26.4 28.9 - 24.9 25.8 28.2 - 24.3 25.2 27.6 - 23.7 24.6 26.9 - 22.5 23.3 25.6 - 20.8 21.6 23.7 - S/T 0.70 0.59 0.41 0.73 0.61 0.42 0.75 0.62 0.43 0.77 0.64 0.45 0.80 0.67 0.46 0.81 0.67 0.47 AT 19 16 12 19 16 12 19 16 13 19 17 13 19 16 12 18 15 12 875 kW 1.87 1.90 1.96 2.00 2.04 2.10 2.11 2.15 2.22 2.21 2.26 2.32 2.30 2.34 2.41 2.37 2.42 2.49 Amps 6.8 6.9 7.1 7.3 7.5 7.7 7.9 8.1 8.4 8.5 8.7 9.0 9.0 9.2 9.5 9.5 9.8 10.1 HiPR 214 230 243 240 259 273 273 294 311 311 335 354 350 377 398 387 416 440 Lo PR 104 110 120 110 117 127 114 121 132 120 127 139 125 133 146 130 138 151 MBh 27.6 28.6 31.3 26.9 27.9 30.6 26.3 27.3 29.9 25.7 26.6 29.1 24.4 25.3 27.7 22.6 23.4 25.6 S/T 0.73 0.61 0.42 0.75 0.63 0.44 0.77 0.65 0.45 0.80 0.67 0.46 0.83 0.69 0.48 0.84 0.70 0.48 AT 18 16 12 19 16 12 19 16 12 19 16 12 19 16 12 17 15 11 70 1000 kW 1.91 1.95 2.00 2.04 2.08 2.14 2.16 2.20 2.27 2.26 2.31 2.38 2.35 2.40 2.47 2.43 2.48 2.55 Amps 6.9 7.1 7.3 7.5 7.7 7.9 8.2 8.3 8.6 8.7 8.9 9.2 9.3 9.5 9.8 9.8 10.1 10.4 HiPR 221 238 251 248 267 282 282 303 320 321 345 365 361 388 410 399 429 453 Lo PR 107 114 124 113 120 131 117 125 136 123 131 143 129 138 150 134 142 155 MBh 28.4 29.5 32.3 27.8 28.8 31.5 27.1 28.1 30.8 26.4 27.4 30.0 25.1 26.0 28.5 23.3 24.1 26.4 S/T 0.76 0.64 0.44 0.79 0.66 0.46 0.81 0.68 0.47 0.84 0.70 0.48 0.87 0.73 0.50 0.88 0.73 0.51 AT 18 15 12 18 16 12 18 16 12 18 16 12 18 15 12 17 14 11 1125 kW 1.92 1.96 2.02 2.06 2.10 2.16 2.18 2.22 2.29 2.28 2.33 2.40 2.37 2.42 2.49 2.45 2.50 2.57 Amps 7.0 7.2 7.4 7.6 7.8 8.0 8.2 8.4 8.7 8.8 9.0 9.3 9.4 9.6 9.9 9.9 10.1 10.5 HiPR 223 240 253 250 269 284 285 306 323 324 349 368 365 392 414 403 434 458 Lo PR 1 108 115 125 114 121 133 119 126 138 125 133 145 131 139 152 135 144 157 MBh 25.9 26.7 28.9 31.0 25.3 26.0 28.2 30.3 24.7 25.4 27.5 29.5 24.1 24.8 26.8 28.8 22.9 23.6 25.5 27.4 21.2 21.8 23.6 25.4 S/T 0.80 0.71 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.57 0.37 0.88 0.78 0.59 0.38 0.91 0.81 0.62 0.40 0.92 0.82 0.62 0.40 AT 22 20 16 11 22 20 17 11 22 20 17 11 22 20 17 12 22 20 16 11 20 19 15 11 875 kW 1.88 1.92 1.97 2.03 2.01 2.05 2.11 2.17 2.13 2.17 2.23 2.30 2.23 2.27 2.34 2.41 2.31 2.36 2.43 2.51 2.39 2.44 2.51 2.59 Amps 6.8 7.0 7.2 7.5 7.4 7.5 7.8 8.1 8.0 8.2 8.5 8.8 8.5 8.8 9.0 9.4 9.1 9.3 9.6 10.0 9.6 9.9 10.2 10.6 Hi PR 216 233 246 256 243 261 276 288 276 297 314 327 314 338 357 373 354 381 402 419 391 421 444 463 Lo PR 105 111 122 130 111 118 129 137 115 122 134 142 121 129 140 150 127 135 147 157 131 139 152 162 MBh 28.1 28.9 31.3 33.6 27.4 28.2 30.5 32.8 26.8 27.5 29.8 32.0 26.1 26.9 29.1 31.2 24.8 25.5 27.6 29.7 23.0 23.6 25.6 27.5 S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.60 0.38 0.91 0.81 0.61 0.40 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41 AT 21 20 16 11 22 20 16 11 22 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10 75 1000 kW 1.92 1.96 2.02 2.08 2.06 2.10 2.16 2.22 2.18 2.22 2.29 2.36 2.28 2.33 2.40 2.47 2.37 2.42 2.49 2.57 2.45 2.50 2.57 2.66 Amps 7.0 7.2 7.4 7.7 7.6 7.8 8.0 8.3 8.2 8.4 8.7 9.0 8.8 9.0 9.3 9.7 9.4 9.6 9.9 10.3 9.9 10.2 10.5 10.9 HiPR 223 240 253 264 250 269 284 297 285 306 323 337 324 349 368 384 365 392 414 432 403 434 458 478 Lo PR 108 115 125 134 114 121 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167 MBh 28.9 29.8 32.2 34.6 28.2 29.1 31.5 33.8 27.6 28.4 30.7 33.0 26.9 27.7 30.0 32.2 25.5 26.3 28.5 30.5 23.7 24.4 26.4 28.3 S/T 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.92 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.99 0.88 0.67 0.43 1.00 0.89 0.67 0.43 AT 20 19 15 11 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 19 18 15 10 1125 kW 1.94 1.97 2.03 2.09 2.07 2.11 2.18 2.24 2.19 2.24 2.30 2.37 2.30 2.35 2.42 2.49 2.39 2.44 2.51 2.59 2.47 2.52 2.60 2.68 Amps 7.1 7.2 7.5 7.8 7.6 7.8 8.1 8.4 8.3 8.5 8.8 9.1 8.9 9.1 9.4 9.7 9.4 9.7 10.0 10.4 10.0 10.2 10.6 11.0 Hi PR 225 242 256 267 253 272 287 300 287 309 327 341 327 352 372 388 368 396 419 437 407 438 462 482 Lo PR 109 116 127 135 115 123 134 143 120 127 139 148 126 134 146 156 132 140 153 163 136 145 158 169 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (NA) conditions Amps = outdoor unit amps (comp.+fan) High and low pressures are measured at the liquid and suction service valves. kW = Total system power k V N 0) IN O W O N Q 0 3 0 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 859E I 952F 1052F 1152F D: ENTERING INDOOR WET BULB TEMPERATURE MBh 26.4 26.9 28.8 30.8 25.7 26.3 28.1 30.0 25.1 25.7 27.4 29.3 24.5 25.1 26.8 28.6 23.3 23.8 25.4 27.2 21.6 22.0 23.6 25.2 S/T 0.88 0.82 0.67 0.50 0.91 0.85 0.69 0.52 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00 0.94 0.77 0.57 AT 24 23 20 16 25 24 20 16 25 24 20 16 25 24 21 16 24 23 20 16 23 22 19 15 875 kW 1.90 1.93 1.99 2.04 2.03 2.07 2.13 2.19 2.14 2.19 2.25 2.32 2.25 2.29 2.36 2.43 2.33 2.38 2.45 2.53 2.41 2.46 2.53 2.61 Amps 6.9 7.0 7.3 7.5 7.4 7.6 7.9 8.2 8.1 8.3 8.5 8.9 8.6 8.8 9.1 9.5 9.2 9.4 9.7 10.1 9.7 10.0 10.3 10.7 Hi PR 219 235 248 259 245 264 279 291 279 300 317 331 318 342 361 376 357 385 406 424 395 425 449 468 Lo PR 106 113 123 131 112 119 130 138 116 124 135 144 122 130 142 151 128 136 149 158 132 141 154 164 MBh 28.6 29.2 31.2 33.3 27.9 28.5 30.5 32.6 27.2 27.8 29.7 31.8 26.6 27.1 29.0 31.0 25.2 25.8 27.6 29.5 23A 23.9 25.5 27.3 S/T 0.91 0.85 0.69 0.52 0.94 0.88 0.72 0.54 0.96 0.90 0.74 0.55 1.00 0.93 0.76 0.57 1.00 0.97 0.79 0.59 1.00 0.98 0.80 0.59 AT 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 23 23 20 16 21 21 19 15 80 1000 kW 1.94 1.97 2.03 2.09 2.07 2.11 2.18 2.24 2.19 2.24 2.30 2.37 2.30 2.35 2.42 2.49 2.39 2.44 2.51 2.59 2.47 2.52 2.60 2.68 Amps 7.1 7.2 7.5 7.8 7.6 7.8 8.1 8.4 8.3 8.5 8.8 9.1 8.9 9.1 9.4 9.7 9.4 9.7 10.0 10.4 10.0 10.2 10.6 11.0 Hi PR 225 242 256 267 253 272 287 300 287 309 327 341 327 352 372 388 368 396 419 437 407 438 463 482 Lo PR 109 116 127 135 115 123 134 143 120 127 139 148 126 134 146 156 132 140 153 163 136 145 158 169 MBh 29.4 30.1 32.1 34.3 28.7 29.4 31.4 33.5 28.0 28.7 30.6 32.7 27.4 28.0 29.9 31.9 26.0 26.6 28.4 30.3 24.1 24.6 26.3 28.1 S/T 0.95 0.89 0.73 0.54 1.00 0.93 0.75 0.56 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.83 0.62 1.00 1.00 0.83 0.62 AT 23 22 19 15 23 22 19 15 23 22 19 15 22 23 19 16 21 22 19 15 20 20 18 14 1125 kW 1.95 1.99 2.05 2.11 2.09 2.13 2.19 2.26 2.21 2.25 2.32 2.39 2.32 2.36 2.44 2.51 2.41 2.46 2.53 2.61 2.48 2.54 2.62 2.70 Amps 7.1 7.3 7.5 7.8 7.7 7.9 8.2 8.5 8.4 8.6 8.9 9.2 9.0 9.2 9.5 9.8 9.5 9.8 10.1 10.5 10.1 10.3 10.7 11.1 Hi PR 228 245 259 270 255 275 290 303 290 312 330 344 331 356 376 392 372 400 423 441 411 442 467 487 Lo PR 110 117 128 136 116 124 135 144 121 129 141 150 127 135 148 157 133 142 155 165 138 147 160 170 MBh 26.8 27.3 28.6 30.5 26.2 26.7 28.0 29.8 25.6 26.1 27.3 29.1 24.9 25.4 26.6 28.4 23.7 24.2 25.3 27.0 22.0 22.4 23.4 25.0 S/T 0.92 0.89 0.80 0.65 0.95 0.92 0.83 0.67 0.98 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.92 0.74 AT 26 25 24 21 26 26 24 21 26 26 24 21 26 26 25 21 25 25 24 21 23 24 23 20 875 kW 1.91 1.95 2.00 2.06 2.04 2.08 2.14 2.21 2.16 2.20 2.27 2.34 2.26 2.31 2.38 2.45 2.35 2.40 2.47 2.55 2.43 2.48 2.55 2.63 Amps 6.9 7.1 7.3 7.6 7.5 7.7 7.9 8.2 8.1 8.3 8.6 8.9 8.7 8.9 9.2 9.6 9.3 9.5 9.8 10.2 9.8 10.1 10.4 10.8 Hi PR 221 238 251 262 248 267 281 294 282 303 320 334 321 345 365 380 361 388 410 428 399 429 453 473 Lo PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 143 153 129 137 150 160 134 142 155 165 MBh 29.1 29.6 31.0 33.1 28.4 28.9 30.3 32.3 27.7 28.2 29.6 31.6 27.0 27.6 28.9 30.8 25.7 26.2 27.4 29.2 23.8 24.2 25.4 27.1 S/T 0.95 0.92 0.83 0.67 0.99 0.95 0.86 0.70 1.00 0.98 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.77 1.00 1.00 0.95 0.77 AT 25 25 24 20 26 25 24 21 25 25 24 21 25 25 24 21 24 24 24 21 22 22 22 19 85 1000 kW 1.95 1.99 2.05 2.11 2.09 2.13 2.19 2.26 2.21 2.25 2.32 2.39 2.32 2.36 2.44 2.51 2.41 2.46 2.53 2.61 2.48 2.54 2.62 2.70 Amps 7.1 7.3 7.5 7.8 7.7 7.9 8.2 8.5 8.4 8.6 8.9 9.2 9.0 9.2 9.5 9.8 9.5 9.8 10.1 10.5 10.1 10.3 10.7 11.1 Hi PR 228 245 259 270 255 275 290 303 290 312 330 344 331 356 376 392 372 400 423 441 411 442 467 487 Lo PR 110 117 128 136 116 124 135 144 121 129 141 150 127 135 148 157 133 142 155 165 138 147 160 170 MBh 29.9 30.5 31.9 34.1 29.2 29.8 31.2 33.3 28.5 29.1 30.5 32.5 27.8 28.4 29.7 31.7 26.4 27.0 28.2 30.1 24.5 25.0 26.2 27.9 S/T 1.00 0.96 0.87 0.70 1.00 1.00 0.90 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.95 0.77 1.00 1.00 0.99 0.80 1.00 1.00 1.00 0.81 AT 24 24 23 20 24 24 23 20 23 24 23 20 23 23 23 20 22 22 23 20 20 20 21 18 1125 kW 1.97 2.00 2.06 2.12 2.10 2.15 2.21 2.28 2.23 2.27 2.34 2.41 2.33 2.38 2.45 2.53 2.43 2.48 2.55 2.63 2.50 2.56 2.64 2.72 Amps 7.2 7.4 7.6 7.9 7.8 8.0 8.2 8.5 8.5 8.7 8.9 9.3 9.0 9.3 9.6 9.9 9.6 9.9 10.2 10.6 10.2 10.4 10.8 11.2 Hi PR 230 247 261 272 258 278 293 306 293 316 333 348 334 359 380 396 376 404 427 445 415 447 472 492 Lo PR 111 118 129 138 118 125 137 145 122 130 142 151 128 137 149 159 135 143 156 166 139 148 162 172 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k z 0 rn 0 n O O r- z G1 ZD OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F D: ENTERING INDOOR WET BULB TEMPERATURE MBh 29.1 29.5 30.4 - 28.8 29.2 30.1 - 28.1 28.5 29.4 - 26.8 27.2 28.0 - 25.2 25.6 26.5 - 23.7 24.1 25.0 - S/T 0.62 O.S4 0.40 0.63 0.55 0.41 0.65 0.57 0.44 0.67 0.59 0.46 1.00 0.62 0.48 1.00 0.67 0.53 AT 20 18 15 20 18 15 20 18 15 20 18 15 20 18 14 21 19 15 875 kW 1.67 1.67 1.67 1.86 1.86 1.86 2.07 2.07 2.07 2.30 2.30 2.30 2.55 2.55 2.55 2.85 2.85 2.85 Amps 6.0 6.0 6.0 6.9 6.8 6.8 7.8 7.8 7.8 8.9 8.8 8.8 10.0 10.0 10.0 11.4 11.4 11.4 HiPR 241 242 244 280 281 282 319 321 322 362 363 365 409 410 412 458 459 461 Lo PR 123 125 128 130 132 135 137 139 142 143 144 147 148 150 153 155 156 159 MBh 29.5 29.9 30.8 29.2 29.6 30.5 28.5 28.9 29.7 27.2 27.6 28.4 25.6 26.0 26.8 24.1 24.5 25.4 S/T 0.68 0.60 0.47 0.69 0.61 0.47 0.71 0.64 0.50 1.00 0.66 0.52 1.00 0.68 0.54 1.00 0.73 0.59 AT 19 17 13 19 17 13 19 17 14 19 17 13 18 17 13 20 18 14 70 1000 kW 1.68 1.68 1.68 1.87 1.87 1.87 2.08 2.08 2.08 2.31 2.31 2.31 2.56 2.56 2.56 2.86 2.86 2.86 Amps 6.0 6.0 6.0 6.9 6.9 6.9 7.9 7.9 7.8 8.9 8.9 8.9 10.1 10.1 10.0 11.4 11.4 11.4 HiPR 243 245 246 282 283 284 322 323 324 364 366 367 411 412 414 460 461 463 Lo PR 125 126 129 132 134 137 139 140 144 144 146 149 150 151 154 157 158 161 MBh 29.9 30.3 31.2 29.7 30.1 31.0 28.9 29.3 30.2 27.6 28.0 28.9 26.0 26.4 27.3 24.6 25.0 25.8 S/T 0.72 0.64 0.50 0.72 0.65 0.51 0.75 0.67 0.53 1.00 0.69 0.55 1.00 0.71 0.57 1.00 0.77 0.63 AT 18 16 13 18 16 12 18 16 13 18 16 12 17 16 12 19 17 13 1125 kW 1.69 1.69 1.69 1.88 1.88 1.88 2.09 2.09 2.09 2.32 2.32 2.31 2.57 2.57 2.57 2.87 2.87 2.87 Amps 6.1 6.1 6.1 6.9 6.9 6.9 7.9 7.9 7.9 8.9 8.9 8.9 10.1 10.1 10.1 11.5 11.5 11.4 HiPR 245 247 248 284 285 286 323 325 326 366 368 369 413 414 416 462 463 465 Lo PR 1 127 128 131 134 136 139 141 142 146 146 148 151 152 153 156 159 160 163 MBh 29.1 29.5 30.4 31.7 28.9 29.3 30.1 31.5 28.1 28.5 29.4 30.7 26.8 27.2 28.1 29.4 25.2 25.6 26.5 27.8 23.7 24.1 25.0 26.3 S/T 0.75 0.68 0.54 0.39 0.76 0.68 0.54 0.40 1.00 0.71 0.57 0.42 1.00 0.73 0.59 0.44 1.00 0.75 0.61 0.46 1.00 1.00 0.66 0.52 AT 24 22 19 15 24 22 19 15 24 22 19 15 24 22 19 15 24 22 18 15 25 23 19 16 875 kW 1.67 1.67 1.67 1.68 1.86 1.86 1.86 1.87 2.07 2.07 2.07 2.08 2.30 2.30 2.29 2.31 2.55 2.55 2.55 2.56 2.85 2.85 2.85 2.86 Amps 6.0 6.0 6.0 6.0 6.8 6.8 6.8 6.9 7.8 7.8 7.8 7.9 8.9 8.8 8.8 8.9 10.0 10.0 10.0 10.1 11.4 11.4 11.4 11.4 HiPR 242 243 244 249 280 281 282 287 320 321 322 327 363 364 365 370 409 410 412 416 458 459 461 465 Lo PR 123 125 128 133 131 132 135 140 137 139 142 147 143 144 147 153 148 150 153 158 155 156 160 165 MBh 29.5 29.9 30.8 32.1 29.2 29.6 30.5 31.8 28.5 28.9 29.8 31.1 27.2 27.6 28.4 29.8 25.6 26.0 26.9 28.2 24.1 24.5 25.4 26.7 S/T 0.81 0.74 0.60 0.45 0.82 0.74 0.60 0.46 1.00 0.77 0.63 0.48 1.00 0.79 0.65 0.50 1.00 0.81 0.67 0.53 1.00 1.00 0.73 0.58 AT 23 21 18 14 23 21 17 14 23 21 18 14 23 21 17 14 22 21 17 14 24 22 18 15 75 1000 kW 1.68 1.68 1.68 1.69 1.87 1.87 1.87 1.88 2.08 2.08 2.08 2.09 2.31 2.31 2.30 2.32 2.56 2.56 2.56 2.57 2.86 2.86 2.86 2.87 Amps 6.0 6.0 6.0 6.1 6.9 6.9 6.9 6.9 7.9 7.8 7.8 7.9 8.9 8.9 8.9 8.9 10.1 10.1 10.0 10.1 11.4 11.4 11.4 11.5 HiPR 244 245 246 251 282 283 285 289 322 323 324 329 365 366 367 372 411 412 414 418 460 462 463 467 Lo PR 125 126 129 135 132 134 137 142 139 140 144 149 144 146 149 154 150 151 155 160 157 158 161 167 MBh 30.0 30.4 31.2 32.6 29.7 30.1 31.0 32.3 28.9 29.3 30.2 31.5 27.6 28.0 28.9 30.2 26.0 26.4 27.3 28.6 24.6 25.0 25.9 27.2 S/T 0.85 0.77 0.63 0.49 1.00 0.78 0.64 0.49 1.00 0.80 0.66 0.52 1.00 0.82 0.68 0.54 1.00 0.85 0.71 0.56 1.00 1.00 0.76 0.61 AT 22 20 17 13 22 20 17 13 22 20 17 13 22 20 17 13 22 20 16 13 23 21 17 14 1125 kW 1.69 1.69 1.69 1.70 1.88 1.88 1.87 1.89 2.09 2.09 2.08 2.10 2.32 2.32 2.31 2.33 2.57 2.57 2.57 2.58 2.87 2.87 2.86 2.88 Amps 6.1 6.1 6.0 6.1 6.9 6.9 6.9 7.0 7.9 7.9 7.9 7.9 8.9 8.9 8.9 9.0 10.1 10.1 10.1 10.1 11.5 11.5 11.4 11.5 HiPR 246 247 248 253 284 285 287 291 324 325 326 331 367 368 369 374 413 414 416 420 462 464 465 469 Lo PR 127 128 132 137 134 136 139 144 141 142 146 151 146 148 151 156 152 153 157 162 159 160 163 169 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) High and low pressures are measured at the liquid and suction service valves. kW = Total system power k V N 0) Ln IN O Uj F-� N Q 0 3 0 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 29.3 29.7 30.5 31.9 29.0 29.4 30.3 31.6 28.2 28.7 29.5 30.9 26.9 27.3 28.2 29.5 25.3 25.8 26.6 27.9 23.9 24.3 25.2 26.5 S/T 1.00 0.80 0.66 0.52 1.00 0.81 0.67 0.52 1.00 0.84 0.70 0.55 1.00 0.86 0.72 0.57 1.00 1.00 0.74 0.59 1.00 1.00 0.79 0.65 AT 28 26 23 19 28 26 23 19 28 26 23 19 28 26 23 19 28 26 22 19 29 27 24 20 875 kW 1.67 1.67 1.67 1.68 1.86 1.86 1.86 1.87 2.07 2.07 2.07 2.08 2.30 2.30 2.30 2.31 2.55 2.55 2.55 2.56 2.85 2.85 2.85 2.86 Amps 6.0 6.0 6.0 6.0 6.9 6.8 6.8 6.9 7.8 7.8 7.8 7.9 8.9 8.8 8.8 8.9 10.0 10.0 10.0 10.1 11.4 11.4 11.4 11.4 Hi PR 242 243 245 249 280 281 283 287 320 321 323 327 363 364 366 370 409 410 412 416 459 460 462 466 Lo PR 124 125 128 133 131 133 136 141 138 139 142 148 143 145 148 153 149 150 153 158 155 157 160 165 MBh 29.6 30.1 30.9 32.3 29.4 29.8 30.7 32.0 28.6 29.0 29.9 31.2 27.3 27.7 28.6 29.9 25.7 26.1 27.0 28.3 24.3 24.7 25.5 26.9 S/T 1.00 0.87 0.73 0.58 1.00 0.87 0.73 0.59 1.00 0.90 0.76 0.61 1.00 1.00 0.78 0.63 1.00 1.00 0.80 0.65 1.00 1.00 0.85 0.71 AT 27 25 22 18 27 25 22 18 27 25 22 18 27 25 21 18 27 25 21 18 28 26 22 19 80 1000 kW 1.68 1.68 1.68 1.69 1.87 1.87 1.87 1.88 2.08 2.08 2.08 2.09 2.31 2.31 2.30 2.32 2.56 2.56 2.56 2.57 2.86 2.86 2.86 2.87 Amps 6.0 6.0 6.0 6.1 6.9 6.9 6.9 6.9 7.9 7.9 7.8 7.9 8.9 8.9 8.9 8.9 10.1 10.1 10.0 10.1 11.4 11.4 11.4 11.5 Hi PR 244 245 247 251 282 283 285 289 322 323 325 329 365 366 368 372 411 413 414 418 461 462 464 468 Lo PR 125 127 130 135 133 134 138 143 139 141 144 149 145 146 150 155 150 152 155 160 157 159 162 167 MBh 30.1 30.5 31.4 32.7 29.8 30.3 31.1 32.5 29.1 29.5 30.4 31.7 27.8 28.2 29.1 30.4 26.2 26.6 27.5 28.8 24.7 25.1 26.0 27.3 S/T 1.00 0.90 0.76 0.61 1.00 0.91 0.77 0.62 1.00 0.93 0.79 0.65 1.00 1.00 0.81 0.67 1.00 1.00 0.84 0.69 1.00 1.00 0.89 0.74 AT 26 24 21 17 26 24 21 17 26 24 21 17 26 24 21 17 26 24 20 17 27 25 21 18 1125 kW 1.69 1.69 1.69 1.70 1.88 1.88 1.88 1.89 2.09 2.09 2.09 2.10 2.32 2.32 2.31 2.33 2.57 2.57 2.57 2.58 2.87 2.87 2.86 2.88 Amps 6.1 6.1 6.1 6.1 6.9 6.9 6.9 7.0 7.9 7.9 7.9 7.9 8.9 8.9 8.9 9.0 10.1 10.1 10.1 10.1 11.5 11.5 11.4 11.5 Hi PR 246 247 249 253 284 285 287 291 324 325 327 331 367 368 370 374 413 415 416 420 463 464 466 470 Lo PR 127 129 132 137 135 136 140 145 141 143 146 151 147 148 152 157 152 154 157 162 159 161 164 169 MBh 29.8 30.2 31.0 32.4 29.5 29.9 30.8 32.1 28.7 29.1 30.0 31.3 27.4 27.8 28.7 30.0 25.8 26.2 27.1 28.4 24.4 24.8 25.7 27.0 S/T 1.00 0.91 0.77 0.62 1.00 0.91 0.77 0.63 1.00 1.00 0.80 0.65 1.00 1.00 0.82 0.67 1.00 1.00 0.84 0.70 1.00 1.00 1.00 0.75 AT 32 30 26 23 31 30 26 23 32 30 26 23 31 30 26 23 31 29 26 22 32 31 27 24 875 kW 1.68 1.68 1.67 1.69 1.87 1.86 1.86 1.88 2.08 2.07 2.07 2.09 2.30 2.30 2.30 2.31 2.56 2.56 2.55 2.57 2.86 2.85 2.85 2.86 Amps 6.0 6.0 6.0 6.1 6.9 6.9 6.8 6.9 7.8 7.8 7.8 7.9 8.9 8.9 8.9 8.9 10.0 10.0 10.0 10.1 11.4 11.4 11.4 11.4 Hi PR 243 244 246 250 281 282 284 288 321 322 324 328 364 365 367 371 411 412 413 418 460 461 463 467 Lo PR 125 127 130 135 133 134 138 143 139 141 144 149 145 147 150 155 150 152 155 160 157 159 162 167 MBh 30.1 30.5 31.4 32.7 29.9 30.3 31.2 32.5 29.1 29.5 30.4 31.7 27.8 28.2 29.1 30.4 26.2 26.6 27.5 28.8 24.8 25.2 26.0 27.4 S/T 1.00 0.97 0.83 0.68 1.00 1.00 0.84 0.69 1.00 1.00 0.86 0.72 1.00 1.00 0.88 0.74 1.00 1.00 0.90 0.76 1.00 1.00 1.00 0.81 AT 30 29 25 22 30 29 25 22 31 29 25 22 30 29 25 22 30 28 25 21 31 29 26 22 85 1000 kW 1.69 1.69 1.68 1.70 1.88 1.87 1.87 1.89 2.09 2.08 2.08 2.10 2.31 2.31 2.31 2.32 2.57 2.57 2.56 2.58 2.87 2.86 2.86 2.87 Amps 6.1 6.0 6.0 6.1 6.9 6.9 6.9 7.0 7.9 7.9 7.9 7.9 8.9 8.9 8.9 9.0 10.1 10.1 10.1 10.1 11.4 11.4 11.4 11.5 Hi PR 245 246 248 252 283 284 286 290 323 324 326 330 366 367 369 373 413 414 415 420 462 463 465 469 Lo PR 127 129 132 137 135 136 139 145 141 143 146 151 147 148 151 157 152 154 157 162 159 161 164 169 MBh 30.6 31.0 31.9 33.2 30.3 30.7 31.6 32.9 29.6 30.0 30.9 32.2 28.3 28.7 29.5 30.9 26.7 27.1 28.0 29.3 25.2 25.6 26.5 27.8 S/T 1.00 1.00 0.86 0.72 1.00 1.00 0.87 0.72 1.00 1.00 0.90 0.75 1.00 1.00 0.92 0.77 1.00 1.00 1.00 0.79 1.00 1.00 1.00 0.85 AT 29 28 24 21 29 28 24 21 30 28 24 21 29 28 24 21 29 27 24 20 30 28 25 22 1125 kW 1.70 1.69 1.69 1.71 1.88 1.88 1.88 1.89 2.09 2.09 2.09 2.10 2.32 2.32 2.32 2.33 2.58 2.57 2.57 2.59 2.87 2.87 2.87 2.88 Amps 6.1 6.1 6.1 6.1 7.0 6.9 6.9 7.0 7.9 7.9 7.9 8.0 9.0 8.9 8.9 9.0 10.1 10.1 10.1 10.2 11.5 11.5 11.5 11.5 Hi PR 247 248 250 254 285 286 288 292 325 326 328 332 368 369 371 375 415 416 417 422 464 465 467 471 Lo PR 129 131 134 139 137 138 141 147 143 145 148 153 149 150 153 159 154 156 159 164 161 163 166 171 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k z 0 rt, 0 O O r_ z G1 ZD OUTDOOR AMBIENT TEMPERATURE 652F 752F 859E I 952F 1052F 1152F D: ENTERING INDOOR WET BULB TEMPERATURE MBh 30.6 31.7 34.7 - 29.8 30.9 33.9 - 29.1 30.2 33.1 - 28.4 29.5 32.3 - 27.0 28.0 30.7 - 25.0 25.9 28.4 - S/T 0.73 0.61 0.42 0.76 0.63 0.44 0.78 0.65 0.45 0.80 0.67 0.47 0.84 0.70 0.48 0.84 0.70 0.49 AT 20 17 13 20 17 13 20 17 13 20 17 13 20 17 13 18 16 12 1050 kW 2.23 2.27 2.34 2.39 2.44 2.51 2.53 2.58 2.66 2.65 2.70 2.79 2.75 2.81 2.90 2.84 2.90 2.99 Amps 8.1 8.3 8.5 8.7 8.9 9.2 9.5 9.7 10.0 10.1 10.4 10.7 10.8 11.1 11.4 11.5 11.7 12.1 HiPR 219 236 249 246 265 280 280 301 318 319 343 362 359 386 408 396 427 450 Lo PR 103 109 120 109 116 126 113 120 131 119 126 138 124 132 144 129 137 149 MBh 33.1 34.3 37.6 32.3 33.5 36.7 31.6 32.7 35.8 30.8 31.9 35.0 29.3 30.3 33.2 27.1 28.1 30.8 S/T 0.76 0.64 0.44 0.79 0.66 0.46 0.81 0.68 0.47 0.83 0.70 0.48 0.87 0.72 0.50 0.87 0.73 0.51 AT 19 17 13 20 17 13 20 17 13 20 17 13 19 17 13 18 16 12 70 1200 kW 2.28 2.33 2.39 2.44 2.49 2.57 2.59 2.64 2.72 2.71 2.77 2.85 2.82 2.88 2.97 2.91 2.97 3.07 Amps 8.3 8.5 8.8 9.0 9.2 9.5 9.8 10.0 10.3 10.4 10.7 11.1 11.1 11.4 11.8 11.8 12.1 12.5 HiPR 226 243 257 254 273 288 289 311 328 329 354 374 370 398 420 409 440 464 Lo PR 106 113 123 112 119 130 116 124 135 122 130 142 128 136 149 133 141 154 MBh 34.1 35.3 38.7 33.3 34.5 37.8 32.5 33.7 36.9 31.7 32.9 36.0 30.1 31.2 34.2 27.9 28.9 31.7 S/T 0.80 0.67 0.46 0.83 0.69 0.48 0.85 0.71 0.49 0.87 0.73 0.51 0.91 0.76 0.53 0.92 0.76 0.53 AT 19 16 12 19 16 12 19 16 12 19 16 12 19 16 12 17 15 11 1350 kW 2.30 2.34 2.41 2.46 2.51 2.59 2.61 2.66 2.74 2.73 2.79 2.88 2.84 2.90 2.99 2.94 3.00 3.09 Amps 8.4 8.6 8.9 9.1 9.3 9.6 9.8 10.1 10.4 10.5 10.8 11.2 11.2 11.5 11.9 11.9 12.2 12.6 HiPR 228 246 260 256 276 291 292 314 331 332 357 377 374 402 424 413 444 469 Lo PR 107 114 124 113 120 131 118 125 137 124 131 144 130 138 150 134 143 156 MBh 31.1 32.0 34.6 37.2 30.4 31.3 33.8 36.3 29.6 30.5 33.0 35.4 28.9 29.8 32.2 34.6 27.5 28.3 30.6 32.8 25.4 26.2 28.4 30.4 S/T 0.83 0.75 0.56 0.36 0.86 0.77 0.58 0.38 0.89 0.79 0.60 0.39 0.91 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.96 0.86 0.65 0.42 AT 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 21 20 16 11 1050 kW 2.25 2.29 2.36 2.43 2.41 2.45 2.53 2.60 2.55 2.60 2.68 2.76 2.67 2.73 2.81 2.90 2.78 2.83 2.92 3.01 2.87 2.93 3.02 3.11 Amps 8.1 8.3 8.6 8.9 8.8 9.0 9.3 9.7 9.6 9.8 10.1 10.5 10.2 10.5 10.8 11.3 10.9 11.2 11.6 12.0 11.6 11.9 12.3 12.7 HiPR 222 239 252 263 249 268 283 295 283 304 321 335 322 347 366 382 362 390 412 430 400 431 455 475 Lo PR 104 111 121 129 110 117 128 136 114 121 133 141 120 128 139 148 126 134 146 155 130 138 151 161 MBh 33.7 34.7 37.5 40.3 32.9 33.9 36.6 39.3 32.1 33.1 35.8 38.4 31.3 32.2 34.9 37.5 29.8 30.6 33.2 35.6 27.6 28.4 30.7 33.0 S/T 0.86 0.77 0.59 0.38 0.90 0.80 0.61 0.39 0.92 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.98 0.88 0.67 0.43 0.99 0.89 0.67 0.43 AT 22 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 22 21 17 12 21 19 16 11 75 1200 kW 2.30 2.34 2.41 2.48 2.46 2.51 2.59 2.67 2.61 2.66 2.74 2.83 2.73 2.79 2.88 2.97 2.84 2.90 2.99 3.09 2.94 3.00 3.09 3.19 Amps 8.4 8.6 8.9 9.2 9.1 9.3 9.6 10.0 9.9 10.1 10.4 10.8 10.5 10.8 11.2 11.6 11.2 11.5 11.9 12.3 11.9 12.2 12.6 13.1 Hi PR 228 246 260 271 256 276 291 304 292 314 331 346 332 357 377 394 374 402 425 443 413 444 469 489 Lo PR 107 114 124 133 113 120 131 140 118 125 137 146 124 131 144 153 130 138 150 160 134 143 156 166 MBh 34.7 35.7 38.6 41.5 33.9 34.9 37.7 40.5 33.1 34.0 36.9 39.6 32.3 33.2 36.0 38.6 30.6 31.6 34.2 36.7 28.4 29.2 31.6 34.0 S/T 0.91 0.81 0.61 0.39 0.94 0.84 0.64 0.41 0.96 0.86 0.65 0.42 0.99 0.89 0.67 0.43 1.00 0.92 0.70 0.45 1.00 0.93 0.70 0.45 AT 21 20 16 11 22 20 16 11 22 20 16 11 22 20 16 11 21 20 16 11 19 19 15 10 1350 kW 2.32 2.36 2.43 2.50 2.48 2.53 2.61 2.69 2.63 2.68 2.76 2.85 2.76 2.81 2.90 2.99 2.86 2.93 3.02 3.11 2.96 3.02 3.12 3.22 Amps 8.4 8.7 8.9 9.3 9.1 9.4 9.7 10.0 9.9 10.2 10.5 10.9 10.6 10.9 11.3 11.7 11.3 11.6 12.0 12.5 12.0 12.3 12.7 13.2 HiPR 231 248 262 274 259 279 294 307 295 317 335 349 335 361 381 398 377 406 429 447 417 449 474 494 Lo PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) High and low pressures are measured at the liquid and suction service valves. kW = Total system power k V N Ln IN O Ga N Q 0 3 0 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 959F 1052F 1152F D: ENTERING INDOOR WET BULB TEMPERATURE MBh 31.6 32.3 34.5 36.9 30.9 31.6 33.7 36.1 30.2 30.8 32.9 35.2 29.4 30.1 32.1 34.3 28.0 28.6 30.5 32.6 25.9 26.5 28.3 30.2 S/T 0.91 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.97 0.91 0.74 0.55 1.00 0.94 0.77 0.57 1.04 0.98 0.79 0.59 1.05 0.98 0.80 0.60 AT 25 24 21 17 26 25 21 17 26 25 21 17 26 25 22 17 25 24 21 17 24 23 20 16 1050 kW 2.26 2.31 2.38 2.45 2.42 2.47 2.55 2.62 2.57 2.62 2.70 2.78 2.69 2.75 2.83 2.92 2.80 2.86 2.94 3.04 2.89 2.95 3.04 3.14 Amps 8.2 8.4 8.7 9.0 8.9 9.1 9.4 9.8 9.7 9.9 10.2 10.6 10.3 10.6 11.0 11.4 11.0 11.3 11.7 12.1 11.7 12.0 12.4 12.8 Hi PR 224 241 254 265 251 270 285 298 286 307 325 339 325 350 370 386 366 394 416 434 404 435 460 479 Lo PR 105 112 122 130 111 118 129 137 115 123 134 143 121 129 141 150 127 135 147 157 131 140 152 162 MBh 34.3 35.0 37.4 40.0 33.5 34.2 36.5 39.1 32.7 33.4 35.7 38.1 31.9 32.6 34.8 37.2 30.3 30.9 33.1 35.3 28.1 28.7 30.6 32.7 S/T 0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.56 1.00 0.95 0.77 0.57 1.00 0.98 0.79 0.59 1.00 1.00 0.82 0.62 1.00 1.00 0.83 0.62 AT 25 24 21 17 25 24 21 17 25 24 21 17 24 24 21 17 23 24 21 17 21 22 19 16 80 1200 kW 2.32 2.36 2.43 2.50 2.48 2.53 2.61 2.69 2.63 2.68 2.76 2.85 2.76 2.81 2.90 2.99 2.87 2.93 3.02 3.11 2.96 3.02 3.12 3.22 Amps 8.4 8.7 8.9 9.3 9.1 9.4 9.7 10.0 9.9 10.2 10.5 10.9 10.6 10.9 11.3 11.7 11.3 11.6 12.0 12.5 12.0 12.3 12.7 13.2 Hi PR 231 248 262 274 259 279 294 307 295 317 335 349 335 361 381 398 377 406 429 447 417 449 474 494 Lo PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167 MBh 35.3 36.1 38.5 41.2 34.5 35.2 37.6 40.2 33.7 34.4 36.7 39.3 32.8 33.5 35.8 38.3 31.2 31.9 34.1 36.4 28.9 29.5 31.5 33.7 S/T 1.00 0.93 0.76 0.57 1.00 0.97 0.79 0.59 1.00 1.00 0.81 0.60 1.00 1.00 0.83 0.62 1.00 1.00 0.86 0.65 1.00 1.00 0.87 0.65 AT 24 23 20 16 23 23 20 16 23 23 20 16 22 23 20 16 21 22 20 16 20 20 19 15 1350 kW 2.33 2.38 2.45 2.52 2.50 2.55 2.63 2.71 2.65 2.70 2.78 2.87 2.78 2.83 2.92 3.02 2.89 2.95 3.04 3.14 2.98 3.05 3.14 3.24 Amps 8.5 8.7 9.0 9.4 9.2 9.5 9.8 10.1 10.0 10.3 10.6 11.0 10.7 11.0 11.4 11.8 11.4 11.7 12.1 12.6 12.1 12.4 12.9 13.3 Hi PR 233 251 265 276 262 281 297 310 297 320 338 353 339 365 385 402 381 410 433 452 421 453 479 499 Lo PR 109 116 127 135 116 123 134 143 120 128 139 148 126 134 146 156 132 141 153 163 137 145 159 169 MBh 32.2 32.8 34.4 36.7 31.4 32.0 33.6 35.8 30.7 31.3 32.8 34.9 29.9 30.5 32.0 34.1 28.4 29.0 30.4 32.4 26.3 26.9 28.1 30.0 S/T 0.96 0.92 0.83 0.68 0.99 0.96 0.87 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.96 0.78 AT 27 27 25 22 27 27 25 22 27 27 25 22 26 27 26 22 25 25 25 22 23 24 24 20 1050 kW 2.28 2.33 2.39 2.46 2.44 2.49 2.57 2.64 2.59 2.64 2.72 2.80 2.71 2.77 2.85 2.94 2.82 2.88 2.97 3.06 2.91 2.97 3.07 3.17 Amps 8.3 8.5 8.8 9.1 9.0 9.2 9.5 9.9 9.8 10.0 10.3 10.7 10.4 10.7 11.1 11.5 11.1 11.4 11.8 12.2 11.8 12.1 12.5 13.0 Hi PR 226 243 257 268 254 273 288 301 289 311 328 342 329 354 373 390 370 398 420 438 409 440 464 484 Lo PR 106 113 123 131 112 119 130 139 116 124 135 144 122 130 142 151 128 136 149 159 133 141 154 164 MBh 34.9 35.5 37.2 39.7 34.1 34.7 36.4 38.8 33.2 33.9 35.5 37.9 32.4 33.1 34.6 36.9 30.8 31.4 32.9 35.1 28.5 29.1 30.5 32.5 S/T 0.99 0.96 0.87 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.95 0.77 1.00 1.00 0.99 0.80 1.00 1.00 0.99 0.81 AT 27 26 25 21 26 26 25 22 25 26 25 22 25 25 25 22 24 24 25 21 22 22 23 20 85 1200 kW 2.33 2.38 2.45 2.52 2.50 2.55 2.63 2.71 2.65 2.70 2.78 2.87 2.78 2.83 2.92 3.02 2.89 2.95 3.04 3.14 2.98 3.05 3.14 3.24 Amps 8.5 8.7 9.0 9.4 9.2 9.5 9.8 10.1 10.0 10.3 10.6 11.0 10.7 11.0 11.4 11.8 11.4 11.7 12.1 12.6 12.1 12.4 12.9 13.3 Hi PR 233 251 265 276 262 281 297 310 297 320 338 353 339 365 385 402 381 410 433 452 421 453 479 499 Lo PR 109 116 127 135 116 123 134 143 120 128 139 148 126 134 146 156 132 141 153 163 137 145 159 169 MBh 35.9 36.6 38.3 40.9 35.1 35.8 37.4 40.0 34.2 34.9 36.6 39.0 33.4 34.1 35.7 38.0 31.7 32.4 33.9 36.1 29.4 30.0 31.4 33.5 S/T 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.96 0.78 1.00 1.00 1.00 0.81 1.00 1.00 1.00 0.84 1.00 1.00 1.00 0.85 AT 24 25 24 21 24 24 24 21 23 24 24 21 23 23 24 21 22 22 23 21 20 20 21 19 1350 kW 2.35 2.40 2.47 2.54 2.52 2.57 2.65 2.73 2.67 2.72 2.81 2.89 2.80 2.86 2.95 3.04 2.91 2.97 3.07 3.16 3.01 3.07 3.17 3.27 Amps 8.6 8.8 9.1 9.4 9.3 9.5 9.9 10.2 10.1 10.4 10.7 11.1 10.8 11.1 11.5 11.9 11.5 11.8 12.2 12.7 12.2 12.5 13.0 13.5 Hi PR 235 253 268 279 264 284 300 313 300 323 341 356 342 368 389 406 385 414 437 456 425 458 483 504 Lo PR 110 117 128 137 117 124 135 144 121 129 141 150 127 135 148 158 133 142 155 165 138 147 160 171 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k z 0 rn 0 n O O r- z G1 ZD OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F D: ENTERING INDOOR WET BULB TEMPERATURE MBh 36.6 37.1 38.2 - 36.3 36.8 37.9 - 35.3 35.9 37.0 - 33.7 34.2 35.3 - 31.7 32.2 33.3 - 29.8 30.4 31.5 - S/T 0.60 0.53 0.39 0.61 0.53 0.40 0.63 0.56 0.42 0.65 0.58 0.44 0.67 0.60 0.46 1.00 0.65 0.51 AT 21 19 15 21 19 15 21 19 16 21 19 15 21 19 15 22 20 16 1050 kW 2.10 2.10 2.10 2.34 2.34 2.34 2.61 2.61 2.60 2.90 2.89 2.89 3.22 3.21 3.21 3.59 3.59 3.59 Amps 7.6 7.6 7.6 8.7 8.7 8.7 9.9 9.9 9.9 11.2 11.2 11.2 12.7 12.7 12.7 14.4 14.4 14.4 HiPR 245 246 248 283 285 286 324 325 327 367 369 370 414 416 417 465 466 467 Lo PR 118 120 123 126 127 130 132 133 136 137 139 142 143 144 147 149 151 154 MBh 37.1 37.6 38.7 36.8 37.3 38.4 35.8 36.3 37.4 34.2 34.7 35.8 32.2 32.7 33.8 30.3 30.8 31.9 S/T 0.66 0.59 0.45 0.67 0.59 0.46 0.69 0.62 0.48 0.71 0.64 0.50 1.00 0.66 0.52 1.00 0.71 0.57 AT 20 18 14 20 18 14 20 18 14 20 18 14 19 17 14 21 19 15 70 1200 kW 2.12 2.11 2.11 2.35 2.35 2.35 2.62 2.62 2.61 2.91 2.91 2.90 3.23 3.23 3.22 3.61 3.60 3.60 Amps 7.7 7.7 7.7 8.8 8.8 8.7 10.0 10.0 10.0 11.3 11.3 11.3 12.8 12.8 12.7 14.5 14.5 14.5 HiPR 247 248 250 286 287 288 326 327 329 370 371 372 417 418 419 467 468 469 Lo PR 120 122 125 127 129 132 134 135 138 139 140 143 144 146 149 151 152 155 MBh 37.7 38.2 39.3 37.4 37.9 39.0 36.4 36.9 38.0 34.8 35.3 36.4 32.7 33.3 34.4 30.9 31.4 32.5 S/T 0.70 0.62 0.48 0.70 0.63 0.49 0.73 0.65 0.52 0.75 0.67 0.54 1.00 0.69 0.56 1.00 0.74 0.61 AT 19 17 13 19 17 13 19 17 13 19 17 13 18 16 13 20 18 14 1350 kW 2.13 2.12 2.12 2.36 2.36 2.36 2.63 2.63 2.62 2.92 2.92 2.91 3.24 3.24 3.23 3.62 3.61 3.61 Amps 7.7 7.7 7.7 8.8 8.8 8.8 10.0 10.0 10.0 11.4 11.3 11.3 12.8 12.8 12.8 14.5 14.5 14.5 HiPR 249 250 252 288 289 290 328 329 331 372 373 374 419 420 421 469 470 472 Lo PR 1 122 124 127 129 131 134 136 137 140 141 142 145 146 148 151 153 154 157 MBh 36.6 37.2 38.3 39.9 36.3 36.8 37.9 39.6 35.4 35.9 37.0 38.6 33.7 34.2 35.3 37.0 31.7 32.2 33.3 35.0 29.9 30.4 31.5 33.2 S/T 0.73 0.65 0.52 0.38 0.74 0.66 0.53 0.38 0.76 0.69 0.55 0.41 1.00 0.70 0.57 0.43 1.00 0.73 0.59 0.45 1.00 0.78 0.64 0.50 AT 25 23 20 16 25 23 20 16 25 23 20 16 25 23 20 16 25 23 19 16 26 24 20 17 1050 kW 2.10 2.10 2.10 2.11 2.34 2.34 2.33 2.35 2.61 2.60 2.60 2.62 2.89 2.89 2.89 2.91 3.22 3.21 3.21 3.23 3.59 3.59 3.59 3.60 Amps 7.6 7.6 7.6 7.7 8.7 8.7 8.7 8.8 9.9 9.9 9.9 10.0 11.2 11.2 11.2 11.3 12.7 12.7 12.7 12.8 14.4 14.4 14.4 14.5 HiPR 245 246 248 252 284 285 286 291 324 325 327 331 368 369 370 375 415 416 417 422 465 466 468 472 Lo PR 118 120 123 128 126 127 130 135 132 133 136 141 137 139 142 147 143 144 147 152 149 151 154 159 MBh 37.1 37.6 38.7 40.4 36.8 37.3 38.4 40.1 35.8 36.4 37.5 39.1 34.2 34.7 35.8 37.5 32.2 32.7 33.8 35.5 30.4 30.9 32.0 33.6 S/T 0.79 0.71 0.58 0.44 0.80 0.72 0.59 0.44 1.00 0.75 0.61 0.47 1.00 0.76 0.63 0.49 1.00 0.79 0.65 0.51 1.00 0.84 0.70 0.56 AT 24 22 18 15 24 22 18 15 24 22 19 15 24 22 18 15 24 22 18 14 25 23 19 16 75 1200 kW 2.11 2.11 2.11 2.13 2.35 2.35 2.35 2.36 2.62 2.62 2.61 2.63 2.91 2.90 2.90 2.92 3.23 3.23 3.22 3.24 3.60 3.60 3.60 3.62 Amps 7.7 7.7 7.6 7.7 8.8 8.8 8.7 8.8 10.0 10.0 10.0 10.0 11.3 11.3 11.3 11.4 12.8 12.8 12.7 12.8 14.5 14.5 14.5 14.5 HiPR 247 248 250 254 286 287 289 293 326 327 329 333 370 371 373 377 417 418 420 424 467 468 470 474 Lo PR 120 122 125 130 127 129 132 137 134 135 138 143 139 140 144 149 144 146 149 154 151 152 155 160 MBh 37.7 38.2 39.3 41.0 37.4 37.9 39.0 40.7 36.4 36.9 38.0 39.7 34.8 35.3 36.4 38.1 32.8 33.3 34.4 36.0 30.9 31.4 32.5 34.2 S/T 0.82 0.75 0.61 0.47 0.83 0.75 0.62 0.48 1.00 0.78 0.64 0.50 1.00 0.80 0.66 0.52 1.00 0.82 0.69 0.54 1.00 0.87 0.74 0.59 U 23 21 17 14 23 21 17 14 23 21 18 14 23 21 17 14 23 21 17 13 24 22 18 15 1350 kW 2.12 2.12 2.12 2.14 2.36 2.36 2.36 2.38 2.63 2.63 2.62 2.64 2.92 2.91 2.91 2.93 3.24 3.24 3.23 3.25 3.61 3.61 3.61 3.63 Amps 7.7 7.7 7.7 7.8 8.8 8.8 8.8 8.9 10.0 10.0 10.0 10.1 11.3 11.3 11.3 11.4 12.8 12.8 12.8 12.9 14.5 14.5 14.5 14.6 Hi PR 249 250 252 256 288 289 291 295 328 329 331 335 372 373 375 379 419 420 422 426 469 470 472 476 Lo PR 122 124 127 132 129 131 134 139 136 137 140 145 141 142 145 150 146 148 151 156 153 154 157 162 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) High and low pressures are measured at the liquid and suction service valves. kW = Total system power k V N 0) Ln IN O Ga V N Q 0 3 0 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E F 952F 1052E 1152F ENTERING INDOOR WET BULB TEMPERATURE •: MBh 36.8 37.4 38.4 40.1 36.5 37.0 38.1 39.8 35.6 36.1 37.2 38.8 33.9 34.4 35.5 37.2 31.9 32.4 33.5 35.2 30.1 30.6 31.7 33.3 S/T 0.85 0.78 0.64 0.50 1.00 0.79 0.65 0.51 1.00 0.81 0.68 0.53 1.00 0.83 0.69 0.55 1.00 0.85 0.72 0.57 1.00 1.00 0.77 0.63 AT 29 27 24 20 29 27 24 20 30 28 24 20 29 27 24 20 29 27 24 20 30 28 25 21 1050 kW 2.10 2.10 2.10 2.12 2.34 2.34 2.34 2.35 2.61 2.61 2.60 2.62 2.90 2.89 2.89 2.91 3.22 3.21 3.21 3.23 3.59 3.59 3.59 3.61 Amps 7.6 7.6 7.6 7.7 8.7 8.7 8.7 8.8 9.9 9.9 9.9 10.0 11.2 11.2 11.2 11.3 12.7 12.7 12.7 12.8 14.4 14.4 14.4 14.5 Hi PR 245 247 248 253 284 285 287 291 325 326 327 332 368 369 371 375 415 416 418 422 465 466 468 472 Lo PR 119 120 123 128 126 128 131 136 132 134 137 142 138 139 142 147 143 145 148 153 150 151 154 159 MBh 37.3 37.8 38.9 40.6 37.0 37.5 38.6 40.3 36.0 36.6 37.6 39.3 34.4 34.9 36.0 37.7 32.4 32.9 34.0 35.7 30.5 31.1 32.2 33.8 S/T 0.91 0.84 0.70 0.56 1.00 0.84 0.71 0.57 1.00 0.87 0.73 0.59 1.00 0.89 0.75 0.61 1.00 1.00 0.78 0.63 1.00 1.00 0.83 0.69 AT 28 26 23 19 28 26 23 19 28 27 23 19 28 26 23 19 28 26 22 19 29 27 24 20 80 1200 kW 2.12 2.11 2.11 2.13 2.35 2.35 2.35 2.37 2.62 2.62 2.61 2.63 2.91 2.91 2.90 2.92 3.23 3.23 3.22 3.24 3.61 3.60 3.60 3.62 Amps 7.7 7.7 7.7 7.7 8.8 8.8 8.7 8.8 10.0 10.0 10.0 10.0 11.3 11.3 11.3 11.4 12.8 12.8 12.7 12.8 14.5 14.5 14.5 14.6 Hi PR 248 249 250 255 286 287 289 293 327 328 329 334 370 371 373 377 417 418 420 424 467 468 470 474 Lo PR 121 122 125 130 128 129 132 137 134 136 139 144 140 141 1" 149 145 146 149 154 151 153 156 161 MBh 37.9 38.4 39.5 41.2 37.6 38.1 39.2 40.9 36.6 37.1 38.2 39.9 35.0 35.5 36.6 38.2 33.0 33.5 34.6 36.2 31.1 31.6 32.7 34.4 S/T 1.00 0.87 0.74 0.60 1.00 0.88 0.74 0.60 1.00 0.90 0.77 0.63 1.00 0.92 0.79 0.65 1.00 1.00 0.81 0.67 1.00 1.00 0.86 0.72 AT 27 25 22 18 27 25 22 18 27 26 22 18 27 25 22 18 27 25 21 18 28 26 23 19 1350 kW 2.13 2.12 2.12 2.14 2.36 2.36 2.36 2.38 2.63 2.63 2.62 2.64 2.92 2.92 2.91 2.93 3.24 3.24 3.23 3.25 3.62 3.61 3.61 3.63 Amps 7.7 7.7 7.7 7.8 8.8 8.8 8.8 8.9 10.0 10.0 10.0 10.1 11.3 11.3 11.3 11.4 12.8 12.8 12.8 12.9 14.5 14.5 14.5 14.6 Hi PR 250 251 252 257 288 289 291 295 329 330 331 336 372 373 375 379 419 420 422 426 469 470 472 476 Lo PR 123 124 127 132 130 131 134 139 136 138 141 146 141 143 146 151 147 148 151 156 153 155 158 163 MBh 37.5 38.0 39.1 40.7 37.1 37.6 38.7 40.4 36.2 36.7 37.8 39.5 34.5 35.0 36.1 37.8 32.5 33.0 34.1 35.8 30.7 31.2 32.3 34.0 S/T 1.00 0.88 0.74 0.60 1.00 0.89 0.75 0.61 1.00 1.00 0.78 0.63 1.00 1.00 0.80 0.65 1.00 1.00 0.82 0.68 1.00 1.00 0.87 0.73 AT 33 31 28 24 33 31 28 24 33 32 28 24 33 31 28 24 33 31 27 24 34 32 29 25 1050 kW 2.11 2.11 2.10 2.12 2.35 2.34 2.34 2.36 2.61 2.61 2.61 2.62 2.90 2.90 2.89 2.91 3.22 3.22 3.22 3.23 3.60 3.60 3.59 3.61 Amps 7.6 7.6 7.6 7.7 8.7 8.7 8.7 8.8 9.9 9.9 9.9 10.0 11.3 11.3 11.2 11.3 12.7 12.7 12.7 12.8 14.5 14.5 14.4 14.5 Hi PR 247 248 249 254 285 286 288 292 326 327 329 333 369 370 372 376 416 417 419 423 466 468 469 473 Lo PR 121 122 125 130 128 129 132 137 134 136 139 144 140 141 144 149 145 146 149 154 151 153 156 161 MBh 37.9 38.5 39.5 41.2 37.6 38.1 39.2 40.9 36.7 37.2 38.3 39.9 35.0 35.5 36.6 38.3 33.0 33.5 34.6 36.3 31.2 31.7 32.8 34.4 S/T 1.00 0.94 0.80 0.66 1.00 0.95 0.81 0.67 1.00 1.00 0.84 0.69 1.00 1.00 0.85 0.71 1.00 1.00 0.88 0.73 1.00 1.00 0.93 0.79 AT 32 30 27 23 32 30 26 23 32 30 27 23 32 30 26 23 32 30 26 22 33 31 27 24 85 1200 kW 2.12 2.12 2.11 2.13 2.36 2.36 2.35 2.37 2.62 2.62 2.62 2.64 2.91 2.91 2.91 2.92 3.23 3.23 3.23 3.25 3.61 3.61 3.60 3.62 Amps 7.7 7.7 7.7 7.8 8.8 8.8 8.8 8.8 10.0 10.0 10.0 10.1 11.3 11.3 11.3 11.4 12.8 12.8 12.8 12.8 14.5 14.5 14.5 14.6 Hi PR 249 250 251 256 287 288 290 294 328 329 331 335 371 372 374 378 418 419 421 425 469 470 471 476 Lo PR 122 124 127 132 130 131 134 139 136 137 140 146 141 143 146 151 147 148 151 156 153 155 158 163 MBh 38.5 39.0 40.1 41.8 38.2 38.7 39.8 41.5 37.2 37.7 38.8 40.5 35.6 36.1 37.2 38.9 33.6 34.1 35.2 36.9 31.7 32.3 33.3 35.0 S/T 1.00 0.97 0.84 0.70 1.00 0.98 0.84 0.70 1.00 1.00 0.87 0.73 1.00 1.00 0.89 0.75 1.00 1.00 0.91 0.77 1.00 1.00 1.00 0.82 AT 31 29 26 22 31 29 25 22 31 29 26 22 31 29 25 22 31 29 25 21 32 30 26 23 1350 kW 2.13 2.13 2.12 2.14 2.37 2.37 2.36 2.38 2.63 2.63 2.63 2.65 2.92 2.92 2.92 2.93 3.24 3.24 3.24 3.26 3.62 3.62 3.61 3.63 Amps 7.7 7.7 7.7 7.8 8.8 8.8 8.8 8.9 10.1 10.0 10.0 10.1 11.4 11.4 11.3 11.4 12.8 12.8 12.8 12.9 14.6 14.6 14.5 14.6 Hi PR 251 252 254 258 289 290 292 296 330 331 333 337 373 374 376 380 420 421 423 427 471 472 473 478 Lo PR 124 126 129 134 132 133 136 141 138 139 142 147 143 145 148 153 149 150 153 158 155 157 160 165 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp +fan) kW = Total system power k z 0 rn 0 n O O r_ Z G1 ZD OUTDOOR AMBIENT TEMPERATURE 652F 752F 859E 959F 1059E 1159F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 36.9 38.2 41.9 - 36.0 37.3 40.9 - 35.2 36.4 39.9 - 34.3 35.6 39.0 - 32.6 33.8 37.0 - 30.2 31.3 34.3 - S/T 0.71 0.59 0.41 0.73 0.61 0.42 0.75 0.63 0.43 0.78 0.65 0.45 0.80 0.67 0.47 0.81 0.68 0.47 AT 20 17 13 20 17 13 20 17 13 20 17 13 20 17 13 18 16 12 1225 kW 2.70 2.76 2.83 2.89 2.95 3.03 3.06 3.12 3.21 3.20 3.27 3.37 3.33 3.39 3.50 3.43 3.50 3.61 Amps 9.9 10.1 10.4 10.7 10.9 11.3 11.6 11.8 12.2 12.3 12.6 13.1 13.1 13.4 13.9 13.9 14.2 14.7 HiPR 219 236 249 246 265 280 280 301 318 319 343 362 359 386 408 396 427 451 Lo PR 102 109 119 108 115 126 113 120 131 118 126 137 124 132 144 128 136 149 MBh 40.0 41.4 45.4 39.0 40.5 44.3 38.1 39.5 43.3 37.2 38.5 42.2 35.3 36.6 40.1 32.7 33.9 37.1 S/T 0.73 0.61 0.42 0.76 0.63 0.44 0.78 0.65 0.45 0.80 0.67 0.47 0.83 0.70 0.48 0.84 0.70 0.49 AT 19 17 13 19 17 13 19 17 13 20 17 13 19 17 13 18 16 12 70 1400 kW 2.76 2.82 2.90 2.96 3.02 3.10 3.13 3.19 3.29 3.28 3.34 3.45 3.40 3.48 3.58 3.51 3.59 3.70 Amps 10.1 10.4 10.7 10.9 11.2 11.6 11.9 12.2 12.6 12.7 13.0 13.4 13.5 13.8 14.3 14.3 14.6 15.1 HiPR 226 243 257 254 273 288 289 311 328 329 354 374 370 398 420 409 440 464 Lo PR 106 112 123 112 119 130 116 123 135 122 130 142 128 136 148 132 141 153 MBh 41.2 42.7 46.7 40.2 41.7 45.7 39.2 40.7 44.6 38.3 39.7 43.5 36.4 37.7 41.3 33.7 34.9 38.3 S/T 0.77 0.64 0.44 0.80 0.67 0.46 0.82 0.68 0.47 0.84 0.70 0.49 0.87 0.73 0.51 0.88 0.74 0.51 AT 18 16 12 19 16 12 19 16 12 19 16 12 19 16 12 17 15 11 1575 kW 2.78 2.84 2.92 2.98 3.04 3.13 3.15 3.21 3.31 3.30 3.37 3.47 3.43 3.50 3.61 3.54 3.62 3.73 Amps 10.2 10.5 10.8 11.0 11.3 11.7 12.0 12.3 12.7 12.8 13.1 13.6 13.6 14.0 14.4 14.4 14.8 15.3 HiPR 228 246 260 256 276 291 292 314 331 332 357 377 374 402 425 413 444 469 Lo PR 1 107 114 124 113 120 131 117 125 136 123 131 143 129 137 150 133 142 155 MBh 37.5 38.6 41.8 44.9 36.6 37.7 40.8 43.8 35.8 36.8 39.9 42.8 34.9 35.9 38.9 41.7 33.1 34.1 36.9 39.6 30.7 31.6 34.2 36.7 S/T 0.80 0.72 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.38 0.91 0.82 0.62 0.40 0.92 0.82 0.62 0.40 AT 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 21 20 16 11 1225 kW 2.72 2.78 2.86 2.94 2.91 2.97 3.06 3.15 3.08 3.14 3.23 3.33 3.23 3.29 3.39 3.50 3.35 3.42 3.53 3.64 3.46 3.53 3.64 3.76 Amps 10.0 10.2 10.5 10.9 10.8 11.0 11.4 11.8 11.7 11.9 12.3 12.8 12.5 12.8 13.2 13.7 13.3 13.6 14.0 14.6 14.0 14.4 14.9 15.4 HiPR 222 239 252 263 249 268 283 295 283 304 321 335 322 347 366 382 363 390 412 430 401 431 455 475 Lo PR 104 110 120 128 109 116 127 135 114 121 132 141 119 127 139 148 125 133 145 155 129 138 150 160 MBh 40.6 41.8 45.3 48.6 39.7 40.9 44.2 47.5 38.7 39.9 43.2 46.3 37.8 38.9 42.1 45.2 35.9 37.0 40.0 43.0 33.3 34.2 37.1 39.8 S/T 0.83 0.75 0.56 0.36 0.86 0.77 0.58 0.38 0.89 0.79 0.60 0.39 0.91 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.96 0.86 0.65 0.42 AT 22 20 17 12 23 21 17 12 23 21 17 12 23 21 17 12 22 21 17 12 21 19 16 11 75 1400 kW 2.78 2.84 2.92 3.01 2.98 3.04 3.13 3.22 3.15 3.21 3.31 3.41 3.30 3.37 3.47 3.58 3.43 3.50 3.61 3.72 3.54 3.62 3.73 3.85 Amps 10.2 10.5 10.8 11.2 11.0 11.3 11.7 12.1 12.0 12.3 12.7 13.2 12.8 13.1 13.6 14.1 13.6 14.0 14.4 15.0 14.4 14.8 15.3 15.9 HiPR 229 246 260 271 256 276 291 304 292 314 331 346 332 357 377 394 374 402 425 443 413 444 469 489 Lo PR 107 114 124 132 113 120 131 139 117 125 136 145 123 131 143 152 129 137 150 160 133 142 155 165 MBh 41.9 43.1 46.6 50.1 40.9 42.1 45.6 48.9 39.9 41.1 44.5 47.7 38.9 40.1 43.4 46.6 37.0 38.1 41.2 44.2 34.3 35.3 38.2 41.0 S/T 0.87 0.78 0.59 0.38 0.91 0.81 0.61 0.39 0.93 0.83 0.63 0.40 0.96 0.86 0.65 0.42 0.99 0.89 0.67 0.43 1.00 0.90 0.68 0.44 AT 21 20 16 11 22 20 16 11 22 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10 1575 kW 2.80 2.86 2.94 3.03 3.00 3.06 3.15 3.25 3.17 3.24 3.34 3.44 3.33 3.40 3.50 3.61 3.46 3.53 3.64 3.75 3.57 3.65 3.76 3.88 Amps 10.3 10.6 10.9 11.3 11.1 11.4 11.8 12.2 12.1 12.4 12.8 13.3 12.9 13.2 13.7 14.2 13.8 14.1 14.6 15.1 14.6 14.9 15.4 16.0 Hi PR 231 248 262 274 259 279 294 307 295 317 335 349 336 361 381 398 377 406 429 447 417 449 474 494 Lo PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 157 167 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) High and low pressures are measured at the liquid and suction service valves. kW = Total system power k V N 0) Ln IN O 44 N N Q 0 3 0 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 859E I 952F 1052F 1152F D: ENTERING INDOOR WET BULB TEMPERATURE MBh 38.2 39.0 41.7 44.5 37.3 38.1 40.7 43.5 36.4 37.2 39.7 42.5 35.5 36.3 38.8 41.4 33.7 34.5 36.8 39.4 31.2 31.9 34.1 36.5 S/T 0.88 0.83 0.67 0.50 0.91 0.86 0.70 0.52 0.94 0.88 0.71 0.53 0.97 0.91 0.74 0.55 1.00 0.94 0.77 0.57 1.01 0.95 0.77 0.58 AT 25 24 21 17 26 24 21 17 26 25 21 17 26 25 21 17 25 24 21 17 24 23 20 16 1225 kW 2.74 2.80 2.88 2.96 2.93 2.99 3.08 3.17 3.10 3.17 3.26 3.36 3.25 3.32 3.42 3.52 3.38 3.45 3.55 3.66 3.49 3.56 3.67 3.79 Amps 10.0 10.3 10.6 11.0 10.8 11.1 11.5 11.9 11.8 12.1 12.5 12.9 12.6 12.9 13.3 13.8 13.4 13.7 14.2 14.7 14.2 14.5 15.0 15.6 Hi PR 224 241 254 265 251 270 286 298 286 308 325 339 325 350 370 386 366 394 416 434 405 435 460 480 Lo PR 105 111 121 129 110 118 128 137 115 122 133 142 121 128 140 149 126 134 147 156 131 139 152 162 MBh 41.4 42.3 45.2 48.3 40.4 41.3 44.1 47.1 39.4 40.3 43.1 46.0 38.5 39.3 42.0 44.9 36.5 37.3 39.9 42.7 33.9 34.6 37.0 39.5 S/T 0.91 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.97 0.91 0.74 0.55 1.00 0.94 0.77 0.57 1.00 0.98 0.79 0.59 1.00 0.98 0.80 0.60 AT 25 24 21 17 25 24 21 17 25 24 21 17 25 24 21 17 24 24 21 17 22 22 19 16 80 1400 kW 2.80 2.86 2.94 3.03 3.00 3.06 3.15 3.25 3.18 3.24 3.34 3.44 3.33 3.40 3.50 3.61 3.46 3.53 3.64 3.75 3.57 3.65 3.76 3.88 Amps 10.3 10.6 10.9 11.3 11.1 11.4 11.8 12.2 12.1 12.4 12.8 13.3 12.9 13.2 13.7 14.2 13.8 14.1 14.6 15.1 14.6 14.9 15.4 16.0 Hi PR 231 248 262 274 259 279 294 307 295 317 335 349 336 361 381 398 377 406 429 447 417 449 474 494 Lo PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 157 167 MBh 42.6 43.5 46.5 49.7 41.6 42.5 45.4 48.6 40.6 41.5 44.3 47.4 39.6 40.5 43.3 46.2 37.6 38.5 41.1 43.9 34.9 35.6 38.1 40.7 S/T 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00 0.95 0.78 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.83 0.62 1.00 1.00 0.84 0.63 AT 24 23 20 16 24 23 20 16 24 23 20 16 23 24 20 16 22 22 20 16 20 21 19 15 1575 kW 2.82 2.88 2.96 3.05 3.02 3.08 3.17 3.27 3.20 3.26 3.36 3.47 3.35 3.42 3.53 3.64 3.49 3.56 3.67 3.78 3.60 3.67 3.79 3.91 Amps 10.4 10.7 11.0 11.4 11.2 11.5 11.9 12.3 12.2 12.5 12.9 13.4 13.0 13.4 13.8 14.3 13.9 14.2 14.7 15.2 14.7 15.1 15.6 16.2 Hi PR 233 251 265 276 262 282 297 310 298 320 338 353 339 365 385 402 381 410 433 452 421 453 479 499 Lo PR 109 116 126 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 168 MBh 38.8 39.6 41.5 44.2 37.9 38.7 40.5 43.2 37.0 37.7 39.5 42.2 36.1 36.8 38.6 41.2 34.3 35.0 36.6 39.1 31.8 32.4 33.9 36.2 S/T 0.92 0.89 0.80 0.65 0.96 0.92 0.83 0.68 0.98 0.95 0.85 0.69 1.00 0.98 0.88 0.72 1.00 1.00 0.92 0.74 1.00 1.00 0.92 0.75 AT 27 26 25 22 27 27 25 22 27 27 25 22 27 27 26 22 26 26 25 22 24 24 24 20 1225 kW 2.76 2.82 2.90 2.98 2.96 3.01 3.10 3.20 3.13 3.19 3.28 3.38 3.28 3.34 3.44 3.55 3.40 3.47 3.58 3.69 3.51 3.59 3.70 3.82 Amps 10.1 10.4 10.7 11.1 10.9 11.2 11.6 12.0 11.9 12.2 12.6 13.0 12.7 13.0 13.4 13.9 13.5 13.8 14.3 14.8 14.3 14.6 15.1 15.7 Hi PR 226 243 257 268 254 273 288 301 289 311 328 342 329 354 374 390 370 398 420 438 409 440 464 484 Lo PR 106 112 123 131 112 119 130 138 116 123 135 143 122 130 141 151 128 136 148 158 132 140 153 163 MBh 42.1 42.9 44.9 47.9 41.1 41.9 43.9 46.8 40.1 40.9 42.8 45.7 39.1 39.9 41.8 44.6 37.2 37.9 39.7 42.4 34.4 35.1 36.8 39.2 S/T 0.96 0.92 0.83 0.68 0.99 0.96 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.96 0.78 AT 26 26 25 21 27 26 25 22 26 26 25 22 26 26 25 22 24 25 25 21 23 23 23 20 85 1400 kW 2.82 2.88 2.96 3.05 3.02 3.08 3.17 3.27 3.20 3.26 3.36 3.47 3.35 3.42 3.53 3.64 3.49 3.56 3.67 3.78 3.60 3.67 3.79 3.91 Amps 10.4 10.7 11.0 11.4 11.2 11.5 11.9 12.3 12.2 12.5 12.9 13.4 13.0 13.4 13.8 14.3 13.9 14.2 14.7 15.2 14.7 15.1 15.6 16.2 Hi PR 233 251 265 276 262 282 297 310 298 320 338 353 339 365 385 402 381 410 433 452 421 453 479 499 Lo PR 109 116 126 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 168 MBh 43.3 44.2 46.3 49.4 42.3 43.2 45.2 48.2 41.3 42.1 44.1 47.1 40.3 41.1 43.0 45.9 38.3 39.0 40.9 43.6 35.5 36.2 37.9 40.4 S/T 1.00 0.97 0.87 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.93 0.75 1.00 1.00 0.96 0.78 1.00 1.00 1.00 0.81 1.00 1.00 1.00 0.81 AT 25 25 24 20 25 25 24 21 24 25 24 21 24 24 24 21 22 23 24 21 21 21 22 19 1575 kW 2.85 2.90 2.98 3.07 3.05 3.11 3.20 3.30 3.22 3.29 3.39 3.49 3.38 3.45 3.55 3.67 3.51 3.59 3.70 3.81 3.63 3.70 3.82 3.94 Amps 10.5 10.8 11.1 11.5 11.3 11.6 12.0 12.4 12.3 12.6 13.0 13.5 13.2 13.5 13.9 14.5 14.0 14.3 14.8 15.4 14.8 15.2 15.7 16.3 Hi PR 235 253 268 279 264 284 300 313 301 323 342 356 342 368 389 406 385 414 438 456 425 458 483 504 Lo PR 110 117 128 136 116 124 135 144 121 128 140 149 127 135 147 157 133 141 154 164 137 146 160 170 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k z 0 rn 0 n O O r- z G1 ZD OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E F 952F 1052F 1152F D: ENTERING INDOOR WET BULB TEMPERATURE MBh 42.6 44.2 48.4 - 41.6 43.2 47.3 - 40.7 42.1 46.2 - 39.7 41.1 45.0 - 37.7 39.1 42.8 - 34.9 36.2 39.6 - S/T 0.70 0.58 0.40 0.72 0.60 0.42 0.74 0.62 0.43 0.77 0.64 0.44 0.79 0.66 0.46 0.80 0.67 0.46 AT 20 17 13 20 17 13 20 17 13 20 17 13 20 17 13 18 16 12 1400 kW 2.95 3.01 3.10 3.16 3.22 3.32 3.34 3.41 3.51 3.50 3.57 3.68 3.64 3.71 3.83 3.76 3.84 3.95 Amps 10.8 11.0 11.4 11.6 11.9 12.3 12.6 12.9 13.4 13.5 13.8 14.3 14.4 14.7 15.2 15.2 15.6 16.1 HiPR 219 235 248 245 264 279 279 300 317 318 342 361 357 385 406 395 425 449 Lo PR 106 113 123 112 119 130 116 124 135 122 130 142 128 136 149 132 141 154 MBh 43.3 44.9 49.2 42.3 43.8 48.0 41.3 42.8 46.9 40.3 41.7 45.7 38.3 39.6 43.4 35.4 36.7 40.2 S/T 0.72 0.60 0.42 0.75 0.63 0.43 0.77 0.64 0.44 0.79 0.66 0.46 0.82 0.69 0.48 0.83 0.69 0.48 AT 19 17 13 19 17 13 19 17 13 20 17 13 19 17 13 18 16 12 70 1500 kW 2.99 3.05 3.14 3.20 3.26 3.36 3.39 3.45 3.56 3.55 3.62 3.73 3.69 3.76 3.88 3.81 3.89 4.01 Amps 10.9 11.2 11.6 11.8 12.1 12.5 12.8 13.1 13.6 13.7 14.1 14.5 14.6 15.0 15.5 15.5 15.8 16.4 HiPR 222 239 2S3 2S0 269 284 284 305 322 323 348 367 364 391 413 402 432 457 Lo PR 108 115 125 114 121 132 118 126 137 124 132 144 130 139 151 135 143 156 MBh 44.8 46.4 50.9 43.8 45.4 49.7 42.7 44.3 48.5 41.7 43.2 47.3 39.6 41.0 45.0 36.7 38.0 41.6 S/T 0.77 0.64 0.44 0.80 0.67 0.46 0.82 0.68 0.47 0.84 0.70 0.49 0.88 0.73 0.51 0.88 0.74 0.51 AT 18 15 12 18 15 12 18 15 12 18 16 12 18 15 12 17 14 11 1800 kW 3.03 3.09 3.18 3.25 3.31 3.41 3.44 3.51 3.61 3.60 3.68 3.79 3.75 3.82 3.94 3.87 3.95 4.07 Amps 11.1 11.4 11.8 12.0 12.3 12.7 13.1 13.4 13.8 14.0 14.3 14.8 14.9 15.2 15.7 15.8 16.1 16.7 HiPR 227 244 258 255 274 289 289 312 329 330 355 375 371 399 421 410 441 466 Lo PR 1 110 117 128 116 124 135 121 128 140 127 135 147 133 141 154 137 146 160 MBh 43.4 44.6 48.3 51.9 42.4 43.6 47.2 50.7 41.3 42.6 46.1 49.5 40.3 41.5 45.0 48.2 38.3 39.5 42.7 45.8 35.5 36.5 39.6 42.5 S/T 0.79 0.71 0.54 0.35 0.82 0.73 0.56 0.36 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.81 0.62 0.40 AT 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 21 20 16 11 1400 kW 2.97 3.03 3.12 3.21 3.18 3.25 3.34 3.44 3.37 3.44 3.54 3.65 3.53 3.60 3.71 3.83 3.67 3.74 3.86 3.98 3.79 3.87 3.99 4.11 Amps 10.9 11.1 11.5 11.9 11.7 12.0 12.4 12.9 12.8 13.1 13.5 14.0 13.6 14.0 14.4 15.0 14.5 14.9 15.4 15.9 15.4 15.7 16.3 16.9 HiPR 221 238 251 262 248 267 282 294 282 303 320 334 321 345 365 380 361 389 410 428 399 429 453 473 Lo PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 143 153 129 138 150 160 134 142 155 165 MBh 44.0 45.3 49.1 52.7 43.0 44.3 47.9 51.4 42.0 43.2 46.8 50.2 41.0 42.2 45.6 49.0 38.9 40.1 43.4 46.5 36.0 37.1 40.2 43.1 S/T 0.82 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.94 0.84 0.63 0.41 0.94 0.84 0.64 0.41 AT 22 20 17 12 22 21 17 12 22 21 17 12 23 21 17 12 22 21 17 12 21 19 16 11 75 1500 kW 3.01 3.07 3.16 3.25 3.22 3.29 3.39 3.49 3.41 3.48 3.59 3.70 3.58 3.65 3.76 3.88 3.72 3.79 3.91 4.04 3.84 3.92 4.04 4.17 Amps 11.0 11.3 11.7 12.1 11.9 12.2 12.6 13.1 13.0 13.3 13.7 14.2 13.8 14.2 14.7 15.2 14.7 15.1 15.6 16.2 15.6 16.0 16.5 17.2 Hi PR 225 242 255 266 252 271 286 299 287 309 326 340 327 351 371 387 367 395 417 435 406 437 461 481 Lo PR 109 116 126 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 168 MBh 45.6 46.9 50.8 54.5 44.5 45.8 49.6 53.2 43.4 44.7 48.4 52.0 42.4 43.6 47.2 50.7 40.3 41.5 44.9 48.2 37.3 38.4 41.6 44.6 S/T 0.87 0.78 0.59 0.38 0.91 0.81 0.61 0.39 0.93 0.83 0.63 0.40 0.96 0.86 0.65 0.42 0.99 0.89 0.67 0.43 1.00 0.90 0.68 0.44 AT 20 19 15 11 21 19 16 11 21 19 16 11 21 19 16 11 20 19 15 11 19 18 14 10 1800 kW 3.06 3.12 3.21 3.30 3.27 3.34 3.44 3.54 3.46 3.53 3.64 3.75 3.63 3.71 3.82 3.94 3.78 3.85 3.97 4.10 3.90 3.98 4.11 4.24 Amps 11.2 11.5 11.9 12.3 12.1 12.4 12.8 13.3 13.2 13.5 14.0 14.5 14.1 14.4 14.9 15.5 15.0 15.4 15.9 16.5 15.9 16.3 16.8 17.5 HiPR 229 247 260 272 257 277 292 305 292 315 332 347 333 358 378 395 375 403 426 444 414 446 470 491 Lo PR 111 118 129 137 117 125 136 145 122 130 142 151 128 136 149 158 134 143 156 166 139 148 161 172 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) High and low pressures are measured at the liquid and suction service valves. kW = Total system power k 51, Q 0 3 0 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052E 1152E •: ENTERING INDOOR WET BULB TEMPERATURE MBh 44.1 45.1 48.2 51.5 43.1 44.0 47.1 50.3 42.1 43.0 45.9 49.1 41.1 41.9 44.8 47.9 39.0 39.9 42.6 45.5 36.1 36.9 39.4 42.2 S/T 0.87 0.82 0.66 0.50 0.90 0.85 0.69 0.51 0.92 0.87 0.71 0.53 0.95 0.89 0.73 0.54 0.99 0.93 0.76 0.56 1.00 0.94 0.76 0.57 AT 25 24 21 17 26 24 21 17 26 24 21 17 26 2S 21 17 25 24 21 17 24 23 20 16 1400 kW 3.00 3.05 3.14 3.24 3.21 3.27 3.37 3.47 3.39 3.46 3.57 3.68 3.56 3.63 3.74 3.86 3.70 3.77 3.89 4.01 3.82 3.90 4.02 4.15 Amps 11.0 11.2 11.6 12.0 11.9 12.1 12.5 13.0 12.9 13.2 13.6 14.1 13.8 14.1 14.6 15.1 14.6 15.0 15.5 16.1 15.5 15.9 16.4 17.1 Hi PR 223 240 253 264 250 269 284 297 285 306 323 337 324 349 368 384 365 393 414 432 403 434 458 478 Lo PR 108 115 126 134 114 121 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167 MBh 44.8 45.8 48.9 52.3 43.8 44.7 47.8 51.1 42.7 43.7 46.6 49.9 41.7 42.6 45.5 48.6 39.6 40.5 43.2 46.2 36.7 37.5 40.0 42.8 S/T 0.90 0.85 0.69 0.51 0.93 0.88 0.71 0.53 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.56 1.00 0.96 0.78 0.59 1.00 0.97 0.79 0.59 AT 25 24 21 16 25 24 21 17 25 24 21 17 25 24 21 17 24 24 21 17 22 22 19 15 80 1500 kW 3.03 3.09 3.18 3.28 3.25 3.31 3.41 3.52 3.44 3.51 3.61 3.73 3.60 3.68 3.79 3.91 3.75 3.82 3.94 4.07 3.87 3.95 4.07 4.20 Amps 11.1 11.4 11.8 12.2 12.0 12.3 12.7 13.2 13.1 13.4 13.8 14.4 14.0 14.3 14.8 15.4 14.9 15.2 15.8 16.3 15.8 16.1 16.7 17.3 Hi PR 227 244 258 269 255 274 289 302 290 312 329 343 330 355 375 391 371 399 422 440 410 441 466 486 Lo PR 110 117 128 136 116 124 135 144 121 128 140 149 127 135 147 157 133 141 154 164 137 146 160 170 MBh 46.4 47.4 50.6 54.1 45.3 46.3 49.4 52.9 44.2 45.2 48.3 51.6 43.1 44.1 47.1 50.3 41.0 41.9 44.7 47.8 38.0 38.8 41.4 44.3 S/T 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00 0.96 0.78 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.83 0.62 1.00 1.00 0.84 0.63 AT 23 22 19 15 23 22 19 15 23 22 19 15 22 23 19 15 21 21 19 15 19 20 18 14 1800 kW 3.08 3.14 3.23 3.33 3.30 3.36 3.46 3.57 3.49 3.56 3.67 3.78 3.66 3.74 3.85 3.97 3.80 3.88 4.01 4.13 3.93 4.01 4.14 4.27 Amps 11.3 11.6 12.0 12.4 12.3 12.6 13.0 13.4 13.3 13.6 14.1 14.6 14.2 14.6 15.1 15.6 15.1 15.5 16.0 16.7 16.1 16.4 17.0 17.7 Hi PR 231 249 263 274 260 279 295 308 295 318 336 350 336 362 382 399 378 407 430 449 418 450 475 496 Lo PR 112 119 130 139 118 126 138 147 123 131 143 152 129 138 150 160 136 144 157 168 140 149 163 173 MBh 44.9 45.8 47.9 51.1 43.9 44.7 46.8 50.0 42.8 43.6 45.7 48.8 41.8 42.6 44.6 47.6 39.7 40.4 42.4 45.2 36.8 37.5 39.2 41.9 S/T 0.91 0.88 0.79 0.64 0.94 0.91 0.82 0.67 0.97 0.93 0.84 0.68 1.00 0.96 0.87 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.91 0.74 AT 27 26 25 22 27 27 25 22 27 27 25 22 27 27 26 22 26 27 25 22 24 25 23 20 1400 kW 3.02 3.08 3.17 3.26 3.23 3.30 3.39 3.50 3.42 3.49 3.59 3.70 3.58 3.66 3.77 3.89 3.73 3.80 3.92 4.04 3.85 3.93 4.05 4.18 Amps 11.1 11.3 11.7 12.1 12.0 12.2 12.7 13.1 13.0 13.3 13.7 14.3 13.9 14.2 14.7 15.3 14.8 15.1 15.6 16.2 15.7 16.0 16.6 17.2 Hi PR 225 242 256 267 253 272 287 300 288 309 327 341 327 352 372 388 368 396 419 437 407 438 463 482 Lo PR 109 116 127 135 115 123 134 143 120 128 139 148 126 134 146 156 132 140 153 163 136 145 159 169 MBh 45.6 46.5 48.7 51.9 44.5 45.4 47.5 50.7 43.5 44.3 46.4 49.5 42.4 43.2 45.3 48.3 40.3 41.1 43.0 45.9 37.3 38.0 39.8 42.5 S/T 0.95 0.91 0.82 0.67 0.98 0.95 0.85 0.69 1.00 0.97 0.87 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.94 0.76 1.00 1.00 0.95 0.77 AT 26 26 25 21 27 26 25 22 27 26 25 22 26 26 25 22 25 25 25 21 23 23 23 20 85 1500 kW 3.06 3.12 3.21 3.30 3.27 3.34 3.44 3.54 3.46 3.53 3.64 3.75 3.63 3.71 3.82 3.94 3.78 3.85 3.97 4.10 3.90 3.98 4.11 4.24 Amps 11.2 11.5 11.9 12.3 12.1 12.4 12.8 13.3 13.2 13.5 14.0 14.5 14.1 14.4 14.9 15.5 15.0 15.4 15.9 16.5 15.9 16.3 16.8 17.5 Hi PR 229 247 260 272 257 277 292 305 292 315 332 347 333 358 379 395 375 403 426 444 414 446 471 491 Lo PR 1 111 118 129 137 117 125 136 145 122 130 142 151 128 136 149 158 134 143 156 166 139 148 161 172 MBh 47.2 48.1 50.4 53.7 46.1 47.0 49.2 52.5 45.0 45.9 48.0 51.2 43.9 44.7 46.9 50.0 41.7 42.5 44.5 47.5 38.6 39.4 41.2 44.0 S/T 1.00 0.97 0.87 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.93 0.75 1.00 1.00 0.96 0.78 1.00 1.00 1.00 0.81 1.00 1.00 1.00 0.81 AT 24 24 23 19 24 24 23 20 23 23 23 20 22 23 23 20 21 22 23 20 20 20 21 18 1800 kW 3.10 3.16 3.25 3.35 3.32 3.39 3.49 3.60 3.52 3.59 3.70 3.81 3.69 3.77 3.88 4.00 3.83 3.92 4.04 4.17 3.96 4.04 4.17 4.31 Amps 11.4 11.7 12.1 12.5 12.4 12.7 13.1 13.6 13.4 13.8 14.2 14.8 14.4 14.7 15.2 15.8 15.3 15.7 16.2 16.8 16.2 16.6 17.2 17.8 Hi PR 234 252 266 277 262 282 298 311 298 321 339 354 340 366 386 403 382 411 434 453 422 455 480 501 Lo PR 113 121 132 140 120 127 139 148 124 132 144 154 131 139 152 162 137 146 159 169 142 151 164 175 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k n z 0 m 0 n O O r_ z G1 a OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 51.4 53.2 58.3 - 50.2 52.0 57.0 - 49.0 50.8 55.6 - 47.8 49.5 54.3 - 45.4 47.1 51.6 - 42.1 43.6 47.8 - S/T 0.73 0.61 0.42 0.76 0.64 0.44 0.78 0.65 0.45 0.80 0.67 0.47 0.84 0.70 0.48 0.84 0.70 0.49 AT 20 17 13 20 17 13 20 17 13 20 17 13 20 17 13 19 16 12 1750 kW 3.42 3.48 3.58 3.65 3.72 3.83 3.86 3.94 4.06 4.05 4.13 4.25 4.20 4.29 4.42 4.34 4.43 4.56 Amps 12.6 12.9 13.3 13.6 13.9 14.4 14.8 15.1 15.6 15.8 16.1 16.7 16.7 17.2 17.7 17.7 18.2 18.8 HiPR 216 233 246 243 261 276 276 297 313 314 338 357 353 380 402 391 420 444 Lo PR 1 103 109 119 109 115 126 113 120 131 118 126 138 124 132 144 128 137 149 MBh 51.4 53.2 58.3 50.2 52.0 57.0 49.0 50.8 55.6 47.8 49.5 54.3 45.4 47.1 51.6 42.1 43.6 47.8 S/T 0.73 0.61 0.42 0.76 0.64 0.44 0.78 0.65 0.45 0.80 0.67 0.47 0.84 0.70 0.48 0.84 0.70 0.49 AT 21 18 14 21 18 14 21 18 14 21 18 14 21 18 14 19 17 13 70 1625 kW 3.42 3.48 3.58 3.65 3.72 3.83 3.86 3.94 4.06 4.05 4.13 4.25 4.20 4.29 4.42 4.34 4.43 4.56 Amps 12.6 12.9 13.3 13.6 13.9 14.4 14.8 15.1 15.6 15.8 16.1 16.7 16.7 17.2 17.7 17.7 18.2 18.8 HiPR 216 233 246 243 261 276 276 297 313 314 338 357 353 380 402 391 420 444 Lo PR 103 109 119 109 115 126 113 120 131 118 126 138 124 132 144 128 137 149 MBh 53.2 55.1 60.4 51.9 53.8 59.0 50.7 52.5 57.6 49.5 51.3 56.2 47.0 48.7 53.4 43.5 45.1 49.4 S/T 0.78 0.65 0.45 0.81 0.67 0.47 0.83 0.69 0.48 0.86 0.71 0.49 0.89 0.74 0.51 0.90 0.75 0.52 AT 17 15 11 17 15 11 17 15 11 17 15 11 17 15 11 16 14 10 2250 kW 3.47 3.53 3.63 3.71 3.78 3.89 3.92 4.00 4.12 4.11 4.19 4.32 4.27 4.36 4.49 4.41 4.50 4.64 Amps 12.8 13.1 13.6 13.9 14.2 14.6 15.0 15.4 15.9 16.0 16.4 17.0 17.1 17.5 18.0 18.1 18.5 19.1 HiPR 220 237 251 247 266 281 281 303 320 320 345 364 361 388 410 398 429 453 Lo PR 105 111 122 111 118 129 115 122 134 121 129 140 127 135 147 131 139 152 MBh 52.2 53.8 58.2 62.5 51.0 52.5 56.9 61.0 49.8 51.3 55.5 59.6 48.6 50.0 54.2 58.1 46.2 47.5 51.5 55.2 42.8 44.0 47.7 51.2 S/T 0.83 0.75 0.56 0.36 0.86 0.77 0.59 0.38 0.89 0.79 0.60 0.39 0.91 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.96 0.86 0.65 0.42 AT 23 21 17 12 23 21 17 12 23 21 18 12 23 22 18 12 23 21 17 12 22 20 16 11 1750 kW 3.44 3.51 3.61 3.71 3.68 3.75 3.86 3.98 3.89 3.97 4.09 4.21 4.08 4.16 4.29 4.42 4.24 4.32 4.46 4.59 4.37 4.46 4.60 4.75 Amps 12.7 13.0 13.4 13.9 13.7 14.1 14.5 15.0 14.9 15.3 15.7 16.3 15.9 16.3 16.8 17.4 16.9 17.3 17.9 18.6 17.9 18.3 18.9 19.6 HiPR 218 235 248 259 245 264 278 290 279 300 317 330 317 342 361 376 357 384 406 423 395 425 448 468 Lo PR 104 110 121 128 110 117 127 136 114 121 132 141 120 127 139 148 125 133 146 155 130 138 151 160 MBh 52.2 53.8 58.2 62.5 51.0 52.5 56.9 61.0 49.8 51.3 55.5 59.6 48.6 50.0 54.2 58.1 46.2 47.5 51.5 55.2 42.8 44.0 47.7 51.2 S/T 0.83 0.75 0.56 0.36 0.86 0.77 0.59 0.38 0.89 0.79 0.60 0.39 0.91 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.96 0.86 0.65 0.42 AT 24 22 18 12 24 22 18 13 24 22 18 13 24 22 18 13 24 22 18 13 22 21 17 12 75 1625 kW 3.44 3.51 3.61 3.71 3.68 3.75 3.86 3.98 3.89 3.97 4.09 4.21 4.08 4.16 4.29 4.42 4.24 4.32 4.46 4.59 4.37 4.46 4.60 4.75 Amps 12.7 13.0 13.4 13.9 13.7 14.1 14.5 15.0 14.9 15.3 15.7 16.3 15.9 16.3 16.8 17.4 16.9 17.3 17.9 18.6 17.9 18.3 18.9 19.6 HiPR 218 235 248 259 245 264 278 290 279 300 317 330 317 342 361 376 357 384 406 423 395 425 448 468 Lo PR 104 110 121 128 110 117 127 136 114 121 132 141 120 127 139 148 125 133 146 155 130 138 151 160 MBh 54.1 55.7 60.3 64.7 52.8 54.4 58.9 63.2 51.6 53.1 57.5 61.7 50.3 51.8 56.1 60.2 47.8 49.2 53.3 57.2 44.3 45.6 49.3 52.9 S/T 0.89 0.79 0.60 0.39 0.92 0.82 0.62 0.40 0.94 0.84 0.64 0.41 0.97 0.87 0.66 0.42 1.00 0.90 0.68 0.44 1.00 0.91 0.69 0.44 AT 20 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 18 17 14 10 2250 kW 3.49 3.56 3.66 3.77 3.73 3.81 3.92 4.04 3.95 4.03 4.15 4.28 4.14 4.22 4.35 4.49 4.30 4.39 4.53 4.67 4.44 4.53 4.67 4.82 Amps 13.0 13.3 13.7 14.2 14.0 14.3 14.8 15.3 15.2 15.5 16.0 16.6 16.2 16.6 17.1 17.8 17.2 17.6 18.2 18.9 18.2 18.7 19.3 20.0 HiPR 223 240 253 264 250 269 284 296 284 306 323 337 324 348 368 384 364 392 414 432 402 433 457 477 Lo PR 106 113 123 131 112 119 130 138 116 124 135 144 122 130 142 151 128 136 149 158 132 141 154 164 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) High and low pressures are measured at the liquid and suction service valves. kW = Total system power k Q 0 3 0 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 859E I 952F 1052F 1152F D: ENTERING INDOOR WET BULB TEMPERATURE MBh 53.2 54.3 58.1 62.1 51.9 53.1 56.7 60.6 50.7 51.8 55.4 59.2 49.5 50.5 54.0 57.7 47.0 48.0 51.3 54.8 43.5 44.5 47.5 50.8 S/T 0.91 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.97 0.91 0.74 0.55 1.00 0.94 0.77 0.57 1.00 0.98 0.80 0.59 1.00 0.98 0.80 0.60 AT 26 24 21 17 26 25 22 17 26 25 22 17 26 25 22 17 25 25 21 17 23 23 20 16 1750 kW 3.47 3.53 3.63 3.74 3.71 3.78 3.89 4.01 3.92 4.00 4.12 4.25 4.11 4.19 4.32 4.45 4.27 4.36 4.49 4.63 4.41 4.50 4.64 4.78 Amps 12.8 13.1 13.6 14.1 13.9 14.2 14.6 15.2 15.0 15.4 15.9 16.5 16.0 16.4 17.0 17.6 17.1 17.5 18.0 18.7 18.1 18.5 19.1 19.8 Hi PR 221 237 251 261 247 266 281 293 281 303 320 334 321 345 364 380 361 388 410 427 398 429 453 472 Lo PR 105 112 122 130 111 118 129 137 115 122 134 142 121 129 140 150 127 135 147 157 131 139 152 162 MBh 53.2 54.3 58.1 62.1 51.9 53.1 56.7 60.6 50.7 51.8 55.4 59.2 49.5 50.5 54.0 57.7 47.0 48.0 51.3 54.8 43.5 44.5 47.5 50.8 S/T 0.91 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.97 0.91 0.74 0.55 1.00 0.94 0.77 0.57 1.00 0.98 0.80 0.59 1.00 0.98 0.80 0.60 AT 27 26 22 18 27 26 23 18 27 26 23 18 27 26 23 18 26 26 22 18 24 24 21 17 80 1625 kW 3.47 3.53 3.63 3.74 3.71 3.78 3.89 4.01 3.92 4.00 4.12 4.25 4.11 4.19 4.32 4.45 4.27 4.36 4.49 4.63 4.41 4.50 4.64 4.78 Amps 12.8 13.1 13.6 14.1 13.9 14.2 14.6 15.2 15.0 15.4 15.9 16.5 16.0 16.4 17.0 17.6 17.1 17.5 18.0 18.7 18.1 18.5 19.1 19.8 Hi PR 221 237 251 261 247 266 281 293 281 303 320 334 321 345 364 380 361 388 410 427 398 429 453 472 Lo PR 105 112 122 130 111 118 129 137 115 122 134 142 121 129 140 150 127 135 147 157 131 139 152 162 MBh 55.0 56.2 60.1 64.2 53.8 54.9 58.7 62.7 52.5 53.6 57.3 61.2 51.2 52.3 55.9 59.7 48.6 49.7 53.1 56.8 45.1 46.0 49.2 52.6 S/T 1.00 0.91 0.74 0.55 1.00 0.94 0.77 0.57 1.00 1.00 0.79 0.59 1.00 1.00 0.81 0.61 1.00 1.00 0.84 0.63 1.00 1.00 0.85 0.64 AT 22 21 18 15 22 21 18 15 21 22 18 15 21 21 19 15 20 20 18 15 18 19 17 14 2250 kW 3.52 3.58 3.69 3.80 3.76 3.84 3.95 4.07 3.98 4.06 4.18 4.31 4.17 4.26 4.39 4.52 4.34 4.42 4.56 4.70 4.48 4.57 4.71 4.86 Amps 13.1 13.4 13.8 14.3 14.1 14.4 14.9 15.5 15.3 15.7 16.2 16.8 16.3 16.7 17.3 17.9 17.4 17.8 18.4 19.1 18.4 18.8 19.5 20.2 Hi PR 225 242 256 267 252 272 287 299 287 309 326 340 327 352 372 388 368 396 418 436 406 437 462 482 Lo PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 143 153 129 137 150 160 134 142 155 165 MBh 54.1 55.1 57.8 61.6 52.8 53.9 56.4 60.2 51.6 52.6 55.1 58.8 50.3 51.3 53.7 57.3 47.8 48.7 51.0 54.5 44.3 45.1 47.3 50.4 S/T 0.96 0.93 0.84 0.68 0.99 0.96 0.87 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.96 0.78 AT 27 27 25 22 28 27 26 22 27 27 26 22 26 27 26 22 25 26 25 22 23 24 24 21 1750 kW 3.49 3.56 3.66 3.77 3.74 3.81 3.92 4.04 3.95 4.03 4.15 4.28 4.14 4.23 4.35 4.49 4.30 4.39 4.53 4.67 4.44 4.53 4.67 4.82 Amps 13.0 13.3 13.7 14.2 14.0 14.3 14.8 15.3 15.2 15.5 16.0 16.6 16.2 16.6 17.1 17.8 17.2 17.6 18.2 18.9 18.2 18.7 19.3 20.0 Hi PR 223 240 253 264 250 269 284 296 284 306 323 337 324 348 368 384 364 392 414 432 402 433 457 477 Lo PR 106 113 123 131 112 119 130 138 116 124 135 144 122 130 142 151 128 136 149 158 132 141 154 164 MBh 54.1 55.1 57.8 61.6 52.8 53.9 56.4 60.2 51.6 52.6 55.1 58.8 50.3 51.3 53.7 57.3 47.8 48.7 51.0 54.5 44.3 45.1 47.3 50.4 S/T 0.96 0.93 0.84 0.68 0.99 0.96 0.87 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.96 0.78 AT 28 28 26 23 29 28 27 23 28 28 27 23 28 28 27 23 26 27 27 23 24 25 25 22 85 1625 kW 3.49 3.56 3.66 3.77 3.74 3.81 3.92 4.04 3.95 4.03 4.15 4.28 4.14 4.23 4.35 4.49 4.30 4.39 4.53 4.67 4.44 4.53 4.67 4.82 Amps 13.0 13.3 13.7 14.2 14.0 14.3 14.8 15.3 15.2 15.5 16.0 16.6 16.2 16.6 17.1 17.8 17.2 17.6 18.2 18.9 18.2 18.7 19.3 20.0 Hi PR 223 240 253 264 250 269 284 296 284 306 323 337 324 348 368 384 364 392 414 432 402 433 457 477 Lo PR 1 106 113 123 131 112 119 130 138 116 124 135 144 122 130 142 151 128 136 149 158 132 141 154 164 MBh 56.0 57.1 59.8 63.8 54.7 55.8 58.4 62.3 53.4 54.4 57.0 60.8 52.1 53.1 55.6 59.3 49.5 50.4 52.8 56.4 45.8 46.7 48.9 52.2 S/T 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.75 1.00 1.00 0.94 0.77 1.00 1.00 0.97 0.79 1.00 1.00 1.00 0.82 1.00 1.00 1.00 0.83 AT 23 23 22 19 22 23 22 19 22 22 22 19 21 22 22 19 20 21 22 19 19 19 20 18 2250 kW 3.54 3.61 3.71 3.82 3.79 3.87 3.98 4.10 4.01 4.09 4.21 4.34 4.20 4.29 4.42 4.56 4.37 4.46 4.60 4.74 4.51 4.61 4.75 4.90 Amps 13.2 13.5 13.9 14.4 14.2 14.6 15.0 15.6 15.4 15.8 16.3 16.9 16.5 16.9 17.4 18.1 17.5 18.0 18.5 19.2 18.6 19.0 19.6 20.4 Hi PR 227 245 258 269 255 274 290 302 290 312 330 344 330 355 375 391 372 400 422 440 411 442 467 487 Lo PR 108 115 125 134 114 121 132 141 119 126 138 147 125 132 145 154 131 139 152 161 135 144 157 167 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k z 0 rn 0 n O O r- z G1 ZD OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 54.2 56.2 61.6 - 53.0 54.9 60.1 - 51.7 53.6 58.7 - 50.4 52.3 57.3 - 47.9 49.7 54.4 - 44.4 46.0 50.4 - S/T 0.66 0.55 0.38 0.68 0.57 0.39 0.70 0.58 0.40 0.72 0.60 0.42 0.75 0.62 0.43 0.75 0.63 0.44 AT 21 18 14 21 19 14 21 19 14 22 19 14 21 18 14 20 17 13 1550 kW 3.75 3.83 3.95 4.04 4.13 4.27 4.31 4.40 4.55 4.54 4.64 4.79 4.73 4.84 5.00 4.90 5.01 5.18 Amps 13.4 13.8 14.3 14.6 15.0 15.5 16.0 16.4 17.0 17.2 17.6 18.3 18.4 18.8 19.5 19.5 20.0 20.8 HiPR 227 244 248 257 276 280 292 314 318 333 358 363 359 386 392 426 458 464 Lo PR 113 116 127 116 120 131 120 124 135 123 127 139 126 130 141 129 133 145 MBh 55.9 57.9 63.4 54.6 56.5 62.0 53.3 55.2 60.5 52.0 53.9 59.0 49.4 51.2 56.1 45.7 47.4 51.9 S/T 0.69 0.58 0.40 0.71 0.60 0.41 0.73 0.61 0.42 0.76 0.63 0.44 0.78 0.66 0.45 0.79 0.66 0.46 AT 20 18 13 20 18 13 20 18 13 21 18 14 20 18 13 19 16 12 70 1750 kW 3.78 3.86 3.99 4.08 4.17 4.31 4.34 4.44 4.59 4.57 4.68 4.83 4.77 4.88 5.05 4.94 5.06 5.23 Amps 13.6 13.9 14.4 14.8 15.1 15.7 16.1 16.6 17.2 17.3 17.8 18.4 18.5 19.0 19.7 19.7 20.2 21.0 HiPR 229 247 250 259 279 283 295 317 322 336 361 366 363 390 396 430 462 469 Lo PR 114 117 128 117 121 132 121 125 136 124 128 140 127 131 143 130 134 146 MBh 56.1 58.2 63.7 54.8 56.8 62.3 53.5 55.5 60.8 52.2 54.1 59.3 49.6 51.4 56.3 45.9 47.6 52.2 S/T 0.70 0.58 0.40 0.72 0.60 0.42 0.74 0.62 0.43 0.77 0.64 0.44 0.80 0.66 0.46 0.80 0.67 0.46 AT 18 16 12 18 16 12 18 16 12 18 16 12 18 16 12 17 15 11 2000 kW 3.81 3.89 4.02 4.11 4.20 4.34 4.38 4.48 4.63 4.61 4.72 4.88 4.81 4.92 5.09 4.98 5.10 5.27 Amps 13.7 14.1 14.6 14.9 15.3 15.8 16.3 16.7 17.3 17.5 18.0 18.6 18.7 19.2 19.9 19.9 20.4 21.2 HiPR 232 249 253 262 282 286 298 320 325 339 365 370 366 394 400 434 467 474 Lo PR 1 115 119 129 118 122 133 122 126 138 126 130 141 128 132 144 131 135 148 MBh 55.1 56.8 61.5 66.0 53.9 55.5 60.0 64.4 52.6 54.1 58.6 62.9 51.3 52.8 57.2 61.4 48.7 50.2 54.3 58.3 45.1 46.5 50.3 54.0 S/T 0.75 0.67 0.51 0.33 0.77 0.69 0.52 0.34 0.79 0.71 0.54 0.35 0.82 0.73 0.55 0.36 0.85 0.76 0.58 0.37 0.86 0.77 0.58 0.37 AT 24 23 18 13 25 23 19 13 25 23 19 13 25 23 19 13 25 23 19 13 23 21 17 12 1550 kW 3.75 3.83 3.95 4.08 4.04 4.13 4.27 4.41 4.31 4.40 4.55 4.70 4.54 4.64 4.79 4.96 4.73 4.84 5.00 5.18 4.90 5.01 5.18 5.36 Amps 13.4 13.8 14.3 14.8 14.6 15.0 15.5 16.2 16.0 16.4 17.0 17.7 17.2 17.6 18.3 19.0 18.4 18.8 19.5 20.3 19.5 20.0 20.8 21.6 HiPR 227 244 248 253 257 276 280 286 292 314 318 326 333 358 363 371 359 386 392 400 426 458 464 475 Lo PR 113 116 127 135 116 120 131 139 120 124 135 144 123 127 139 148 126 130 141 151 129 133 145 154 MBh 56.8 58.5 63.3 67.9 55.5 57.1 61.8 66.4 54.2 55.8 60.4 64.8 52.8 54.4 58.9 63.2 50.2 51.7 55.9 60.0 46.5 47.9 51.8 55.6 S/T 0.78 0.70 0.53 0.34 0.81 0.73 0.55 0.35 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.89 0.80 0.60 0.39 0.90 0.80 0.61 0.39 AT 23 22 18 12 24 22 18 12 24 22 18 12 24 22 18 12 24 22 18 12 22 20 17 11 75 1750 kW 3.78 3.86 3.99 4.12 4.08 4.17 4.31 4.45 4.34 4.44 4.59 4.74 4.57 4.68 4.83 5.00 4.77 4.88 5.05 5.22 4.94 5.06 5.23 5.41 Amps 13.6 13.9 14.4 15.0 14.8 15.1 15.7 16.3 16.1 16.6 17.2 17.9 17.3 17.8 18.4 19.2 18.5 19.0 19.7 20.5 19.7 20.2 21.0 21.8 HiPR 229 247 250 256 259 279 283 289 295 317 322 329 336 361 366 374 363 390 396 404 430 462 469 479 Lo PR 114 117 128 137 117 121 132 141 121 125 136 145 124 128 140 149 127 131 143 152 130 134 146 156 MBh 57.1 58.8 63.6 68.3 55.8 57.4 62.1 66.7 54.4 56.0 60.7 65.1 53.1 54.7 59.2 63.5 50.4 51.9 56.2 60.3 46.7 48.1 52.1 55.9 S/T 0.79 0.71 0.54 0.35 0.82 0.74 0.56 0.36 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.82 0.62 0.40 AT 21 19 16 11 21 19 16 11 21 19 16 11 21 20 16 11 21 19 16 11 20 18 15 10 2000 kW 3.81 3.89 4.02 4.15 4.11 4.20 4.34 4.49 4.38 4.48 4.63 4.78 4.61 4.72 4.88 5.04 4.81 4.92 5.09 5.26 4.98 5.10 5.27 5.46 Amps 13.7 14.1 14.6 15.1 14.9 15.3 15.8 16.5 16.3 16.7 17.3 18.0 17.5 18.0 18.6 19.4 18.7 19.2 19.9 20.7 19.9 20.4 21.2 22.0 HiPR 232 249 253 258 262 282 286 292 298 320 325 332 339 365 370 378 366 394 400 408 434 467 474 484 Lo PR 115 119 129 138 118 122 133 142 122 126 138 147 126 130 141 151 128 132 144 154 131 135 148 157 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) High and low pressures are measured at the liquid and suction service valves. kW = Total system power k n z m 0 n O O r- 'z G1 n n Q 0 3 0 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E F 952F 1052F 1152F D: ENTERING INDOOR WET BULB TEMPERATURE MBh S6.1 S7.4 61.3 65.5 54.8 56.0 59.9 64.0 S3.S S4.7 58.4 62.5 52.2 53.4 57.0 60.9 49.6 S0.7 54.2 S7.9 45.9 46.9 50.2 53.6 S/T 0.82 0.77 0.63 0.47 0.85 0.80 0.6S 0.48 0.87 0.82 0.66 030 0.90 0.84 0.69 0.51 0.93 0.87 0.71 0.53 0.94 0.88 0.72 0.54 AT 27 26 23 18 28 26 23 18 28 26 23 18 28 27 23 19 27 26 23 18 26 25 21 17 1550 kW 3.75 3.83 3.95 4.08 4.04 4.13 4.27 4.41 4.31 4.40 4.55 4.70 4.54 4.64 4.79 4.96 4.73 4.84 5.00 5.18 4.90 5.01 5.18 5.36 Amps 13.4 13.8 14.3 14.8 14.6 15.0 15.5 16.2 16.0 16.4 17.0 17.7 17.2 17.6 18.3 19.0 18.4 18.8 19.5 20.3 19.5 20.0 20.8 21.6 Hi PR 227 244 248 253 257 276 280 286 292 314 318 326 333 358 363 371 359 386 392 400 426 458 464 475 Lo PR 113 116 127 135 116 120 131 139 120 124 135 144 123 127 139 148 126 130 141 151 129 133 145 154 MBh 57.8 59.1 63.1 67.5 56.5 57.7 61.6 65.9 55.1 56.3 60.2 64.3 53.8 55.0 58.7 62.8 51.1 52.2 55.8 59.6 47.3 48.4 51.7 55.2 S/T 0.86 0.81 0.66 0.49 0.89 0.84 0.68 0.51 0.91 0.86 0.70 0.52 0.94 0.88 0.72 0.54 1.00 0.92 0.75 0.56 1.00 0.93 0.75 0.56 AT 26 25 22 17 26 25 22 18 26 25 22 18 27 26 22 18 27 25 22 17 25 24 20 16 80 1750 kW 3.78 3.86 3.99 4.12 4.08 4.17 4.31 4.45 4.34 4.44 4.59 4.74 4.57 4.68 4.83 5.00 4.77 4.88 5.05 5.22 4.94 5.06 5.23 5.41 Amps 13.6 13.9 14.4 15.0 14.8 15.1 15.7 16.3 16.1 16.6 17.2 17.9 17.3 17.8 18.4 19.2 18.5 19.0 19.7 20.5 19.7 20.2 21.0 21.8 Hi PR 229 247 250 256 259 279 283 289 295 317 322 329 336 361 366 374 363 390 396 404 430 462 469 479 Lo PR 114 117 128 137 117 121 132 141 121 125 136 145 124 128 140 149 127 131 143 152 130 134 146 156 MBh 58.1 59.4 63.4 67.8 56.7 58.0 61.9 66.2 55.4 56.6 60.5 64.6 54.0 55.2 59.0 63.1 51.3 52.5 56.0 59.9 47.6 48.6 51.9 55.5 S/T 0.87 0.82 0.66 0.50 0.90 0.85 0.69 0.51 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00 0.94 0.76 0.57 AT 23 22 19 15 24 23 20 16 24 23 20 16 24 23 20 16 24 22 19 16 22 21 18 15 2000 kW 3.81 3.89 4.02 4.15 4.11 4.20 4.34 4.49 4.38 4.48 4.63 4.78 4.61 4.72 4.88 5.04 4.81 4.92 5.09 5.26 4.98 5.10 5.27 5.46 Amps 13.7 14.1 14.6 15.1 14.9 15.3 15.8 16.5 16.3 16.7 17.3 18.0 17.5 18.0 18.6 19.4 18.7 19.2 19.9 20.7 19.9 20.4 21.2 22.0 Hi PR 232 249 253 258 262 282 286 292 298 320 325 332 339 365 370 378 366 394 400 408 434 467 474 484 Lo PR 115 119 129 138 118 122 133 142 122 126 138 147 126 130 141 151 128 132 144 154 131 135 148 157 MBh 57.1 58.2 61.0 65.0 55.8 56.9 59.6 63.5 54.5 55.5 58.1 62.0 53.1 54.2 56.7 60.5 50.5 51.4 53.9 57.5 46.7 47.7 49.9 53.2 S/T 0.86 0.83 0.75 0.61 0.89 0.86 0.78 0.63 0.91 0.88 0.80 0.65 0.94 0.91 0.82 0.67 0.98 0.94 0.85 0.69 0.99 0.95 0.86 0.70 AT 29 29 27 23 29 29 27 24 29 29 27 24 30 29 28 24 29 29 27 24 27 27 25 22 1550 kW 3.75 3.83 3.95 4.08 4.04 4.13 4.27 4.41 4.31 4.40 4.55 4.70 4.54 4.64 4.79 4.96 4.73 4.84 5.00 5.18 4.90 5.01 5.18 5.36 Amps 13.4 13.8 14.3 14.8 14.6 15.0 15.5 16.2 16.0 16.4 17.0 17.7 17.2 17.6 18.3 19.0 18.4 18.8 19.5 20.3 19.5 20.0 20.8 21.6 Hi PR 227 244 248 253 257 276 280 286 292 314 318 326 333 358 363 371 359 386 392 400 426 458 464 475 Lo PR 113 116 127 135 116 120 131 139 120 124 135 144 123 127 139 148 126 130 141 151 129 133 145 154 MBh 58.8 60.0 62.8 67.0 57.5 58.6 61.3 65.4 56.1 57.2 59.9 63.9 54.7 55.8 58.4 62.3 52.0 53.0 55.5 59.2 48.2 49.1 51.4 54.8 S/T 0.90 0.87 0.78 0.64 0.93 0.90 0.81 0.66 0.96 0.92 0.83 0.68 0.99 0.95 0.86 0.70 1.00 0.99 0.89 0.72 1.00 1.00 0.90 0.73 AT 28 27 26 22 28 28 26 23 28 28 26 23 28 28 26 23 27 28 26 23 25 26 24 21 85 1750 kW 3.78 3.86 3.99 4.12 4.08 4.17 4.31 4.45 4.34 4.44 4.59 4.74 4.57 4.68 4.83 5.00 4.77 4.88 5.05 5.22 4.94 5.06 5.23 5.41 Amps 13.6 13.9 14.4 15.0 14.8 15.1 15.7 16.3 16.1 16.6 17.2 17.9 17.3 17.8 18.4 19.2 18.5 19.0 19.7 20.5 19.7 20.2 21.0 21.8 Hi PR 229 247 250 256 259 279 283 289 295 317 322 329 336 361 366 374 363 390 396 404 430 462 469 479 Lo PR 1 114 117 128 137 117 121 132 141 121 125 136 145 124 128 140 149 127 131 143 152 130 134 146 156 MBh 59.1 60.3 63.1 67.3 57.7 58.8 61.6 65.8 56.4 57.4 60.2 64.2 55.0 56.0 58.7 62.6 52.2 53.2 55.8 59.5 48.4 49.3 51.7 55.1 S/T 0.91 0.88 0.80 0.65 0.95 0.91 0.82 0.67 0.97 0.94 0.84 0.69 1.00 0.97 0.87 0.71 1.00 1.00 0.91 0.73 1.00 1.00 0.91 0.74 AT 25 24 23 20 25 25 23 20 25 25 23 20 25 25 24 20 24 24 23 20 22 23 22 19 2000 kW 3.81 3.89 4.02 4.15 4.11 4.20 4.34 4.49 4.38 4.48 4.63 4.78 4.61 4.72 4.88 5.04 4.81 4.92 5.09 5.26 4.98 5.10 5.27 5.46 Amps 13.7 14.1 14.6 15.1 14.9 15.3 15.8 16.5 16.3 16.7 17.3 18.0 17.5 18.0 18.6 19.4 18.7 19.2 19.9 20.7 19.9 20.4 21.2 22.0 Hi PR 232 249 253 258 262 282 286 292 298 320 325 332 339 365 370 378 366 394 400 408 434 467 474 484 Lo PR 115 119 129 138 118 122 133 142 122 126 138 147 126 130 141 151 128 132 144 154 131 135 148 157 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k n n AHRI RATINGS ALL AHRI SYSTEM RATINGS ARE ACCESSIBLE IN THE UNITARY MATCHUP TOOL VIA DAIKIN CITY OR IN THE DAIKIN SYSTEM CONFIGURATOR TOOL VIA PARTNERUNK. 24 www.daikincomfort.com SS -DX 16SA IZ v :' 0 3 0 0 0 3 8 7 6 5 4 3 2 1 ECN REV ZONE DESCRIPTION HK D DATE XXXXXXX A XXXXX GL E DIMENSIONS E MODEL W" D" H" DX16SA0181A* 29 29 32% DX16SA0241A* 29 29 32% DX16SA0301A* 29 29 36% DX16SA0311A* 29 29 38% D DX16SA0361A* 29 29 38% D W D DX16SA0371A* 35% 35% 36% DX16SA0421A* 35% 35% 36% DX16SA0481A* 35% 35% 40 i ' DX16SA0601A* 35% 35% 38% DX16SA0611A* 35% 35Y2 40 C C B I I I H B 0 Daikin Manufacturing Co., LLC A aR DX16SA A SPECIAL CHARACTERISTICS: COMPONEMSANDMATERIA SPECIFIED HEREIN WILLAILSO CONFORM TO THE APPLICABLE SECTION OF GOODMAN MEE 824.01 WORKMANSHIP TILERANIES DWNBV: ENG: STANDARD FOR FIT, FEEL AND FINISH. K, - f GlE.1. SHT10F1 � 6s=6SIGMA V CRITICAL CHARACTERISTIC SIGNIFICANT CHARACTERISTIC Al CONFIDENTIAL PROPERTY OF THE GOODMAN MANl-URING COMPANY, LP. NOTTO BE DISCLOSED TO OTHERS, CDPIED, OR USED FOR ANY PURPOSE O REV EKCEPTAS AUTHORIZED IN WRITING. MUSAGE RETURNED UPON DEMAND, ON COMPLETION OF ORDER, OR OTHER PURPOSE FOR WHICH IT WAS LENT. TUBEHOII.:, .06 G.3 A 8 7 6 5 4 3 1 1-1 m z 1 0 z tA N O_ 0 3 a 0 O 3 Ln N X N rn D CONTROL BOX T1T0 T2T0 L11p L21p ALTERNATE DOUBLE POLE CONTACTOR 9MAIN PU AUX BR 10 BK CM LVJB YL — V ] SEE NOTE 1 BL —C t t LVJB COLOR CODE BK---------- BLACK BIL --------- BLUE BL/PK------- BLUEIPINK STRIPE BR -------BROWN OR -------- ORANGE PU------- PURPLE RD--------- RED Sc WH-------- WHITE YL--------- YELLOW YL/PK-------- YELLOW /PINK STRIPE P121 WIRING CODE FACTORYWIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE--� FIELD WIRING HIGH VOLTAGE« — LOW VOLTAGE — — CSM I 'L RD BK I 1 RerBL PK HPS BL/ K I —Eli COMP MAIN AUX YLJ K UPS OUTDOOR POWER SUPPLY SEE RATING PLATE �""— RCCIF SAFLHPS LPS USED)oEz L(N�_FT­RD iL'C COMPONENrCODE --------- CONTACTOR CSM ----- CORESENSE MODULE C V SEE NOTE 1 CM ----- OUTDOOR FAN MOTOR t t COMP ----COMPRESSOR NOTES: HIPS ------- HIGH PRESSURE SWITCH 1) TO INDOOR UNIT LOW VOLTAGE 10--------- INTERNAL OVERLOAD TERMINAL BLOCK & INDOOR THERMOSTAT. EQUIPMENT GROUND LVJB ------ LOW VOLTAGE JUNCTION BOX 2) START ASSIST FACTORY EQUIPPED WHEN NOTE 3 RCCF ------ RUN CAPACITOR FOR COMPRESSOR & FAN REQUIRED. SA ------- START ASSIST 3) USE COPPER CONDUCTORS ONLY. SC -------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) SR -------- START RELAY FOR COMPRESSOR (OPTIONAL) t t USE N.E.C. CLASS 2 WIRE LPS------- LOW PRESSURE SWITCH V U K CONTROLS SHOWN WITH THERMOSTAT IN'OFF' POSITION. Mm Wiring is subject to change. Always High Voltage: Disconnect all power before servicing or installing this unit. Multiple power refer to the wiring diagram on the I J WARNING sources may be present. Failure to do so may cause property damage, personal injury, or death. unit for the most up-to-date wiring. a••yam 0140R00275-C CONTROLBOX SR J-BL— YL C 1 � 1 O 3 O 0 O 3 (QY� TT TT O L1A L2A BL YL ALTERNATE ONTAOCTOR UBLE POLE I I I BK I I COMP I � MAIN �/YL = RD J BK AUX BK YL BR C S R Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. SC I PU . RD RCC H C O — — YL I YL 1 i 1 B BA J (IF USED INOTE 2 - . R11 I I I I � 4CH EQUIPMENT GROUND SEE NOTE 3 r GR 1 j LVJB YL —Y BL—C tt SEE NOTE 1 COLOR CODE BK ---- BLACK BIL ----- BLUE BIR ------- BROWN OR -------- ORANGE PU-------- PURPLE RD—...... - RED WH---------- WHITE YL--------- YELLOW GR/YL----GREEN/YELLOW STRIP GR--------- GREEN WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE COMPONENT CODE C ------ CONTACTOR CM ------- OUTDOOR FAN MOTOR COMP-- COMPRESSOR 10 ---- INTERNAL OVERLOAD LVJB -- LOW VOLTAGE JUNCTION BOX RCC------- RUN CAPACITOR FOR COMPRESSOR SA ------- START ASSIST SC ---------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) SR-------- START RELAY FOR COMPRESSOR (OPTIONAL) CH— ------ -CRANKCASE HEATER CONTROLS SHOWN WITH THERMOSTAT IN'OFF' POSITION. OUTDOOR POWER SUPPLY SEE RATING PLATE Li CTi 5 SR 2 1 ILZ SC 10 H C y COMP o R C w I RCC ' Z I m p 1 I 1 r S ¢z ZO XO < w A��3 ¢ a CM (IF USED) BK (L1 L2 BK CH RN GR 1 i C CM Y *BL Y C NOTES 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK & INDOOR THERMOSTAT. 2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. 3) USE COPPER CONDUCTORS ONLY. t t USE N.E.C. CLASS 2 WIRE A High Voltage: Disconnect all power before servicing or installing this unit. Multiple power L WARNING sources may be present. Failure to do so may cause property damage, personal injury, or death. 7 0140R00287-A ACCESSORIES 0 0. ABK-20 Anchor Bracket Kit ^ X X X X X X X X X X ABK-21 Anchor Bracket Kit ^ ASC-01 Anti -Short Cycle Kit X X X X X X X X X X CSR-U-1 Hard -start Kit X X X X X X CSR-U-2 Hard -start Kit X X X X X X CSR-U-3 Hard -start Kit X X X 0130ROOOOOS Low -Pressure Switch Kit X X X X X X X X X X LAKT0IA Freeze-Stat Kit X X X X X X X X X X TXV-302 TXV Kit X X X X TXV-422 TXV Kit X X X TXV-482 TXV Kit X TXV-602 TXV Kit X X Contains 20 brackets; four brackets needed to anchor unit to pad Field -installed, non -bleed, expansion valve kit 28 www.daikincomfort.com SS-DX16SA NOTES SS-DX16SA www.daikincomfort.com 29 NOTES Our continuing commitment to quality products may mean a change in specifications without notice. ©2019 DA/K/NMANUFACTUR/NGCOMPANY. L.P. • Houston, Texas • Printed in the USA 30 www.daikincomfort.com SS-DX16SA