Loading...
APPROVED BLD PLN RESUB1 BLD2021-1028+Arch. & SITE_Plan+2.28.2022_2.03.14_PM+2706786CASH �. CRIB TFCHNiG�T. SFRVT�:F.S SITE PLAN PREPARED BY: CASH M. CARR PE. PROJECT NAME: DATE: 2/23/2022 ADDRESS: 9000 196th St, SW EDMONDS PARCEL # 27041900204700 DESCRIPTION OF WORK: INSTALL PATIO COVER PAGE NUMBER: 1 NOTE: PROPERTY LINES AREAS PER GIS DATA. THIS IS NOT A SURVAY. WORK PERFORMED ON NON -CONFORMING STRUCTURES REQUIRES A SURVAY AND/OR WRITEN AGREEMENT OF THE PROPERTY OWNER AS PER COMPLIENCE WITH _ _ _ _ _ _ _ _ _ _ _ _ _ _ 196th ST Sw THE APPLICABLE LAWS AND REGULATIONS. -------------------------__—_ NOTE: CONTRACTOR RESPONSABLE FOR OBTAINING LOCATES FOR ALL UTILITIES. City Of Edmonds Building Department Work PATIO COVER Address 9000 196TH ST SW Owner TRENT Approved Date 03/09/2022 Building Official /�err�ia B�a�r�e�ci Permit Number BLD2021-1028 ELEVATION CALCULATIONS A 350' B 350' C 345' D 345' TOTAL = 1390' AVERAGE ELEVATION = (A+B+C+D)/4 = 347.5' ACTUAL = 357.5' MAXIMUM ELEVATION = 25' +AVERAGE ELEVATION = 372.5' ELEVATION/ A: 350' GENERAL NOTES: APPROVED 1. SHEAR ATTACHMENT ALL EXTERIOR WALLS 4" O.C. AND WITHIN 12" OF PLATE ENDS UNLESS OTHERWISE SPECIFIED. ATTACHMENT PLANS MUST BE SHALL BE 5/8" DIA. BOLT WITH PLATE WASHER AND 7" MIN. EMBEDMENT. ON JOB SITE 2. ALL STRUCTURAL HARDWARE SHALL BE SIMPSON STRONG TIE UNLESS OTHERWISE SPECIFIED. ALL FASTENERS FOR STRUCTURAL HARDWARE SHALL BE AS PER MANUFACTER'S INSTRUCTIONS. ALL HARDWARE APPROVED FOR USE WITH SDS SCREWS OR SD SCREWS SHALL BE ATTACHED WITH SUCH. 3. ALL STRUCTURAL LUMBER SHALL BE #2 DF, #2 HF OR BETTER UNLESS OTHERWISE SPECIFIED. Clty Of EdmOndS 4. ROOF SHEATHING SHALL BE 5/8" MIN. PLYWOOD OSB 5. FLOOR SHEATHING SHALL BE 3/4" T&G PLYWOOD OR OSB UNLESS ARCHITECTURAL PLANS SPECIFY A GREATER THICKNESS. BUIlding Department 6. FLOOR SHEATHING SHALL BE NAILED WITH 8d NAILS 6" O.C. PANEL FIELD, 4" O.C. PANEL EDGES UNLESS OTHERWISE SPECIFIED. 7. ROOF SHEATHING: #8 SCREWS OR 8d RING SHANK NAILS 4" O.C. PANEL EDGES, 6" O.C. PANEL FIELD. APPROVED PIar1S 8. CONCRETE SHALL BE 2500 PSI OR HIGHER COMPRESSIVE STRENGTH UNLESS SPECIFIED 9. ALL EXTERIOR WALLS SHALL BE NAILED WITH lOd NAILS 12" O.C. FIELD, 6" O.C. PANEL EDGES UNLESS OTHERWISE SPECIFIED. 10. NON -BEARING INTERIOR WALL SHALL BE POSITIVELY ATTACHED TOP AND BOTTOM WITH A #10 SCREW TO EACH JOIST. ALL WORK SUBJECT ELEVATION 1 1. ALL ROOF JOISTS SHALL BE FASTENED FOR WIND UPLIFT WITH HURICANE TIES EACH JOIST AT EACH POINT OF SUPPORT. 12. SDWC15600 FULLY THREADED 6"SCREWS MAY BE SUBSTITUED FOR HURICANE TIES. WALL FRAMING ADJACENT TO VAULTED CEALINGS OR OPENINGS IN DIAPHRAM SHALL BE FRAMED WITH FULL HEIGHT TO FIELD C: 345'\ INSPECTION FOR FRAMING. END WALLS AND TRUSSES SHALL BE BRACED TO ROOF 6' O.C. FOR LATERAL LOADS. 13. ALL STRUCTURAL HARDWARE SHALL BE SIMPSON STRONG -TIE OR LOAD RATED EQUIVELENT, UNLESS OTHERWISE SPECIFIED. CODE COMPLIANCE HARDWARE SHALL USE SDS OR SD SCREWS IN ALL INSTANCES ALLOWED. 14. ALL CONCRTEE ANCHORS SHALL BE TITEN HD OR EQUIVELENT UNLESS OTHERWISE SPECIFIED. EPDXY SHALL BESET-XP OR EQUIVELENT. 15. STRAP ALL EXTERIOR WINDOW AND DOOR OPENINGS ADJACENT TO SHEAR WALLS (SW3, SW4, SW5, SW6) WITH LATERAL LSTA24 STRAPS AT CORNERS FOR SHEAR FLOW. APPROVED BY PLANNING T r}��C,IiAP,� �� +¢G� �wnsr�rH'�k�, 4 Rr f?��1. �F � � NORTH 0 10' 20' 30' 40' 50' SCALE: 1 " = 20' Mar 01 2022 Nothing in the permit approval process shall be interpreted as allowing or permitting the maintenance of any currently existing illegal, nonconforming or unpermitted building, structure or site condition which is outside the scope of the permit application, regardless of whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of a separate enforcement action. �' � , o' w W I z � RESIDENCE � I 900 196th St S � I EDMONDS O � ! � iEXISTING DECK ELEVATION B: 350' I I I I I I W I I I I I c� o' w Q w z J o' w O PROPOSED PATIO COVER I I O � DATUM 332' AS PER ELEVATION SNOHOMISH D:345' COUNTY DIGITAL ELEVATION MODEL J EXISTING STRUCTURE 18.0 Zone RS-12 Corner N Flag N Setbacks: Required 'Actual Front 25' > 25' Side 10' > 10' Rear -----�5�--- > 25' Other Height 25' >25' ACTUAL SETBACKS LISTED ARE TO THE RESUB Feb 8 2022 CITY O EDMONDS EVELOP ENT SERVICES PROPOSED PATIO COVER NOTE: INSTALL HU610 WITH 0.162"x3.5" NAILS AS PER MANUFACTER'S INSTRUCTIONS FILL ALL ROUND AND TRIANGULAR HOLES CASH IVL � �CARR►o ENGINEERING PLAN DRAWN BY: CASH M. CARR DATE: 6/26/2021 EDGE OF EXISTING DECK PAGE NUMBER: 2 0 1' 2' 3' 4' 5' I I I I I I SCALE: 1 /4" = 1' NORTF _ }���F1AL� �� y� a�wns�,�, q 0 N 2x, DTT1Z TENSIOIN TIES EACH END FROM ROOF SHEATHING TO STUDS. SPACE 16" O.C. TENSION TIES ATTACH TO JOISTS WITH 3/8"xb" SDWH SCREW � 6' EXISTING DOOR HU610 BEAM HANGER I HU610 BEAM HANGER I I 2x6 HF2 AT 24" O.C. 2x6 HF2 AT 24" O.C. m I J °J° 'n I OD V n X I X � � x I I � 15/32" OSB NAIL 6" O.C. WITH 8d NAILS PERIMETER ................ NAIL 12" O.C. FIELD I I I 5.5"x7.5" GLB (PRESERVATIVE -TREATED LUMBER REQUIRED WHERE FLOOR ■ JOISTS ARE CLOSER THAN 18" TO THE EXPOSED GROUND, I ■WHERE FLOOR GIRDERS ARE CLOSER THAN 12" TO THE (EXPOSED GROUND, ALL WOOD ON CONCRETE OR MASONRY ■ ■IN DIRECT CONTACT WITH THE GROUND, EXTERIOR SIDING, ISHEATHING AND FRAMING WITH A CLEARANCE LESS THAN 6" ■ TO THE GROUND OR 2" TO CONCRETE SURFACES, ANY WOOD I ■ATTACHED DIRECTLY TO THE INTERIOR OF MASONRY OR `CONCRETE WALLS BELOW GRADE. ■ \ 1.75"xl 6" LVL RIM JOIST FASTEN TO STUDS WITH 2x, 0.22"x4" SDWS SCREWS AT 16" O.C. FASTEN TO RIM JOISTS WITH 0.22"x4" SDWS SCREWS AT 8" O.C. I DECK CONSTRUCTION TO CONSIST OF APPROVED ■WOODS OF NATURAL RESISTANCE TO DECAY OR I BE TREATED WOOD AND LABELED ACCORDINGLY. . I RC R317.1 & R317.2 ■ I FASTENERS FOR PRESERVATIVE -TREATED ! ■AND FIRE -RETARDANT -TREATED WOOD SHALL \IBE OF HOT -DIPPED ZINC -COATED GALVANIZED I bxb HF2 POST .STEEL, STAINLESS STEEL, SILICON BRONZE OR ■ ALTERNITIVLY (COPPER. COATING WEIGHTS FOR ZINC -COATED I 5.5"x5.5" GL POST .FASTENERS SHALL BE IN ACCORDANCE WITH ■ 2x, ML24 ANGLES TO POST �ASTM A153. IRC R317.3 2'x2' FOOITNGS RESUB Feb 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT �� 1 L TECH I�1[C; A � c'rnti�rr�rr ENGINI DRAWN BY: CAS DATE: 6/26/� PAGE NUM FOOTING DETAIL 2.0 LEDGER DETAIL LTT1 Z TENSION TIE AS PER ENGINEERING PLAN 3/8"xb" SDWH SCREW TO EXISTING JOISTS ROOFING 15/32" OSB FLASHING GLB `SDWC TRUSS SCREW EACH JOIST ALTERNITIVLY: H1 TIE HU610 BEAM HANGER INSTALL HU610 WITH 0.162"x3.5" NAILS AS PER MANUFACTER'S INSTRUCTIONS FILL ALL ROUND AND TRIANGULAR HOLES 1.75"xl6" LVL RIM JOIST: 1.75"x9.5" LVL RIM JOIST FASTEN TO STUDS WITH 2x, 0.22"x4"SDWS SCREWS AT 16" O.C. FASTEN TO RIM JOISTS WITH 0.22"x4"SDWS SCREWS AT 8" O.C. 0 1' 2' 3' 4' 5' O z 0 O Z x w Q w 2 z _� X w RESUB Feb 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCALE: 1 " = 1 ' TECHNICAL SERVICES SOUTH ELEVATION DRAWN BY: CASH M. CARR DATE: 2/ 1 1 /2022 PAGE NUMBER: 4 ------------------------------------------- i- -' NOTE: EXISTING RESIDENCE PROFILE IS APROXIMATE i" �,- �- 1 2x, 0.22"xb"SDWS SCREWS I I � 5.5"x7.5" GLB 1'-0" MIN. CLEARANCE 2x6 HF2 JOISTS AT 24" o.c. I TO DECK I 2x, ML24 ANGLES ACTUAL HEIGHT I I 15 " OSB SHE I I EXISTING DECK u 5.5"x7.5" GLB u � 5.5"x7.5" GLB 2x, ML24 ANGLES I I � 2x, 0.22"x6"SDWS SCREWS EXISTING DOOR HU610 BEAM HANGER I I 2x, 0.22"x6"SDWS SCREWS '� L AVERAGE GRADE 0 1' 2' 3' 4' 5' i i i i i i SCALE: 1 /4" = 1' _�_ NORTf _ }.���F1tIL� �� y� a�wns�,�, q MAXIMUM HEIGHT RESUB Feb 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT CASH IVL � �CARR►� WEST ELEVATION DRAWN BY: CASH M. CARR DATE: 2/ 1 1 /2022 PAGE NUMBER: 4 MAXIMUM HEIGHT 0 1' 2' 3' 4' 5' i i i i i i SCALE: 1 /4" = 1' NORTF �.� o�wns�ro q 0 �i CV CV Feb 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT