Loading...
APPROVED BLD BLD2021-1201+Plans+8.30.2021_10.40.39_AM+2382730PROJECT NOTES: 1. ALL DIFFUSERS ARE EXISTING AND SHALL BE RELOCATED TO REFLECTED CEILING PLAN LOCATIONS. PROVIDE NEW FLEX DUCT WHEN REQUIRED. 2. ALL TRANSFER GRILLES ARE NEW. 3. EXISTING DUCT HEATERS SHALL REMAIN. 4. NEW DRYER EXHAUST DUCT SHALL CONNECT TO EXISTING EXTERIOR LOUVER. ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE MT1 TENANT IMPROVEMENT 21616 76TH AVENUE WEST #102 EDMONDS, WA 98026 0 NEW 4" C y SUITE 102 REFLECTED CEILING PLAN 1/8" = 1' ROOF TOP HEAT PUMP SCHEDULE TAG MANUFACTURER MODEL STATUS SUPPLY FAN COOLING CAPACITY SEER OPER. WT. CFM RPM HP TOTAL SENSIBLE HP-4 YORK LGH024S4E EXISTING 2000 1275 2 60,100 57,500 13.0 590 ABBREVIATIONS ACC. ACCESSORIES A.F.F ABOVE FINISH FLOOR AHU AIR HANDLER UNIT BTU BRITISH THERMAL UNIT CFM CUBIC FEET PER MINUTE COP COEFFICIENT OF PERFORMANCE DIA./O DIAMETER DWG DRAWING (E) EXISTING EQUIPMENT EA. EACH EC ELECTRONICALLY COMMUNICATED EER ENERGY EFFICIENCY RATIO EF EXHAUSTFAN ERV ENERGY RECOVERY UNIT EXH EXHAUST HP HORSEPOWER/HEAT PUMP MBH THOUSAND BTU'S PER HOUR MCA MINIMUM CURRENT AMPS (N) NEW EQUIPMENT NA NOT APPLICABLE/NOT AVAILABLE NIC NOT IN CONTRACT NTS NOT TO SCALE ACC. OPERATION/OPERATOR OSA OUTSIDE AIR PH PHASE (R) RELOCATED EQUIPMENT RA RETURN AIR RPM REVOLUTIONS PER MINUTE RTU ROOF TOP UNIT SA SUPPLY AIR SEER SEASONAL ENERGY EFFICIENCY RATIO STE. SUITE SQFT SQUARE FEET T THERMOSTAT TYP. TYPICAL WSEC WASHINGTON STATE ENERGY CODE WT. WEIGHT MECHANICAL LEGEND �<_ WALL RETURN GRILLE T-BAR RETURN AIR GRILLE T ®� SUPPLY AIR DIFFUSER 4-WAY 1 VOLUME DAMPER FLEX DUCT 10" DIFFUSER NECK SIZE AND CFM RATE 250 0 THERMOSTAT & TAG m ROUND DUCT DOWN m RTU SQUARE DUCT DROPS ROUND/SQUARE DUCT WITH END CAP DH DUCT HEATER OUTSIDE AIR REQUIREMENTS SPACE NAME OCCUPANCY CLASSIFICATION SPACE AREA CODE OUTSIDE AIR REQUIREMENTS EQUIPMENT TAG DESIGN AIFLOW CFM ACTUAL OUTSIDE AIR CFM CFM PER SQ FT CFM REQUIRED CFM PER PERSON NO. OF PEOPLE CFM REQUIRED TOTAL REQUIRED 101 RECEPTION AREA 252 SQFT 0.06 15 5 8 40 55 CFM HP-4 300 60 102 OFFICE SPACE 95 SQFT 0.06 6 5 2 10 16 CFM HP-4 100 20 103 OFFICE SPACE 97 SQFT 0.06 6 5 2 10 16 CFM HP-4 150 30 104 OFFICE SPACE 92 SQFT 0.06 6 5 2 10 16 CFM HP-4 100 20 105 OFFICE SPACE 92 SQFT 0.06 6 5 2 10 16 CFM HP-4 100 20 106 OFFICE SPACE 100 SQFT 0.06 6 5 2 10 16 CFM HP-4 150 30 107 OFFICE SPACE 100 SQFT 0.06 6 5 2 10 16 CFM HP-4 150 30 108 OFFICE SPACE 100 SQFT 0.06 6 5 2 10 16 CFM HP-4 150 30 109 & 111 HEALTH CLUB/WEIGHT ROOM 1165 SQFT 0.06 70 5 12 60 130 CFM HP-4 750 150 110 STORAGE 110 SQFT 0.06 7 NA NA NA 7 CFM HP-4 50 10 TOTAL REQUIRED MINIMUM VENTILATION AIR: 381.5 CFM TOTALS 3020 540 NOTES: 1. ENSURE EQUIPMENT CAN SATISFY MINIMUM OUTSIDE AIRFLOW REQUIREMENTS. 2. CALCULATIONS PER IMC2015 403.3.1.1. 3. AMOUNT OF SUPPLY AIR SHALL BE APPROXIMATELY EQUAL TO THE AMOUNT OF RETURN AIR. City Of Edmonds Building Department --- -------------- Work MECHSNICAL- ------------------ ------ ----------------- Address 21616 76TH AVE W --------------------------------------- ---------------------------------- Owner MTI PHYSICAL THERAPY ----------------------------------------- Approved Date 09/09/2021 Building Official Erg Cq**-r BLD2021-1201 Permit Number; PROJECT NAME MTI PHYSICAL THERAPY TENANT IMPROVEMENT PROJECT ADDRESS 21616 76TH AVENUE WEST SUIET 102 EDMONDS, WA 98026 PARCEL #: 00461000100101 TENANT: MTI PHYSICAL THERAPY VICINITY MAP Vn V IU11,41 1 T IVIHI-' r f1VJLl� I w�r� I ivl1j i SF NOT TO SCALE PROJECT CONTACTS TENANT: MTI PHYSICAL THERAPY 1560 140TH AVE. NE BELLEVUE, WA 425-746-2475 JIMRIVARD@MTIPT.COM MECHANICAL CONTRACTOR: MECHANICAL & CONTROL SERVICES 6426 18TH ST. E. FIFE, WA 98424 253-926-9777 JOHNM@GROUPMCS.COM SCOPE OF MECHANICAL WORK -RELOCATE EXISTING DIFFUSERS TO ACCOMMODATE NEW FLOOR LAYOUT. GOVERNING CODES 2018 INTERNATIONAL EXISTING BUILDING CODE 2018 UNIFORM BUILDING CODE 2018 INTERNATIONAL FIRE CODE 2020 NATIONAL ELECTRICAL CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 WASHINGTON STATE ENERGY CODE 2018 WASHINGTON STATE AMENDMENTS GENERAL HVAC NOTES 1. MECHANICAL DRAWING ARE DIAGRAMMATIC IN NATURE. FIELD SHALL PROVIDE ALL OFFSETS, CHANGES IN DIRECTION AND TRANSITIONS REQUIRED FOR COMPLETION OF PROJECT. 2. MECHANICAL WORK SHALL BE PERFORMED IN ACCORDANCE AND COMPLY WITH ALL GOVERNING CODES AND REGULATIONS (LOCAL AND STATE). 3. EQUIPMENT SHALL BE INSTALLED IN CONFORMANCE WITH ARCHITECTURAL FEATURES OF BUILDING/SPACE. 4. AIR -DUCT IN UNCONDITIONED SPACES SHALL HAVE A MINIMUM THICKNESS OF 1.5", R-6 INSULATION. AIR -DUCT LOCATED OUTSIDE THE BUILDING SHALL HAVE A MINIMUM OF R-8 INSULATION. SEE WSEC TABLE C403.10.1.2 FOR MORE DETAILS. 5. AIR -DUCT SIZES ON MECHANICAL PLAN ARE CLEAR INSIDE DIMENSIONS. DUCT SIZE SHALL BE UPSIZED TO ALLOW FOR REQUIRED INSULATION. 6. AIR -DUCTS JOINTS, SEAM AND CONNECTIONS SHALL BE SEALED PER 2018 IMC 603.9. 7. BALANCE HVAC SYSTEM PER WSEC C408.2.2. 8. THERMOSTATS SHALL BE SEVEN-DAY TYPE AND HAVE NIGHT SETBACK WITH 5-DEGREE DEADBAND. 9. PROJECT CLOSE OUT DOCUMENTATION & TRAINING OF THE BUILDING OPERATIONS PERSONNEL IS REQUIRED FOR ALL MECHANICAL COMPONENTS, EQUIPMENT AND SYSTEMS. CLOSE OUT DOCUMENTATION SHALL INCLUDE RECORD DOCUMENTS, O&M MANUALS, APPLICABLE WSEC COMPLIANCE FORMS & CALCULATIONS. RECEIVED Aug 30 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT U Z cli LU °6 > J 0C 00 U cw E J O j Z V QEr UZfl 3 w ti L u O 0 U rn LL I� 1z N C�) w N N W co N N 00 L0 LLi N Z CO O i< c0 Li a Z W WN 0 �w� �w� �>o � =o ago �w Z WN rn Lo } p z m z Z �w 3: O O Q w > 6i N H 00 Q N 0 m � z O w a_ U U C0 w w 0 MECH. SET M�i