Loading...
REVIEWED BLD-BLD2021-1361+Calculations+10.4.2021_7.21.34_PM+2444089G✓2 5NGIN4659e Fax954 : (425) 954-2748 P.O. Box 13423 Fax: (425) -7539 Mill Creek, WA 98082 info@cs2engineers.com Civil d Structural Challenge d Success REVIEWED BY CITY OF EDMONDS € BUILDING DEPARTMENT Structural Calculations Strickland Residence Deck Replacement 929 Cary Road Edmonds, WA 98020 (Parcel # 27032400210800) G52 FN61NFF1R✓ Civil d Structural Gh3lIenge d Success - Prepared By: Sung U. Cho, P.E. Prepared Date: September 27, 2021 CS2 No.: 2125 RECEIVED Oct 05 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Project: Strickland Residence Deck Replacement Date: September 27, 2021 Location: Edmonds, WA Prepared By: S. Cho CS2 No: 2125 Pate I. Scope of Work Provide structural design calculations of replacement of the existing deck construction. The project house is located on 929 Cary Road at City of Edmonds. The information in this report summarizes the requirements for construction of structural elements for the gravity loads and lateral loads resisting in conformance with the International Building Code 2018. The engineering of such structural elements and connections are designed to resist the vertical (gravity) loading particular to concrete foundation. Unless noted otherwise, all means and methods used shall be in keeping with good and generally accepted construction practices. Please refer to the following calculations and supporting sketches as well as the architectural drawing package as provided by others. II. Loads/Design Criteria: (IBC 2018 & ASCE 7-16) Please refer to the following calculations 1. Dead Load — See calculation 2. Live Load — Deck = 60 psf 3. Seismic — Ss = 1.291g, S, = 0.455g, Sos = 1.033, Sp, = N/A Site Class D, I = 1.0, R = 6.5 4. Wind — Exposure B, Basic Wind Speed (V3s) = 98 mph, I = 1.0 5. Concrete Design Parameter Concrete compressive strength, f'c = 3,000 psi Concrete steel reinforcing strength, fy = 60,000 psi 6. Foundation Design Parameter (assumed) Allowable soil bearing pressure = 1,500 psf References: 1. IBC 2018 2. ASCE 7-16 3. ACI 318-14 4. SPDWS 2015 5. NDS 2018 III. Conclusions and Recommendations General contractor shall verify all existing dimensions, member sizes and conditions prior to commencing any work. All dimensions of existing condition shown on the reference are intended as guidelines only and must be verified in field. Any discrepancies shall be called to the attention of the architect or engineer and shall be resolved before proceeding with the work. Contractor shall provide temporary bracing for the structure and structural components until all final connections have been completed in accordance with the plans. TEL: (425) 408-2748 P.O. Box 13423 Page 1 of 21 FAX: (425) 954-7539 Mill Creek, WA 98082 info@cs2engineers.com Project: Strickland Residence Deck Replacement Location: Edmonds, WA Date: September 27, 2021 Prepared By: S. Cho CS2 No: 2125 Page Design Calculation TEL: (425) 408-2748 P.O. Box 13423 Page 2 of 21 FAX: (425) 954-7539 Mill Creek, WA 98082 info@cs2engineers.com P.O. Box 13423 - G52 ffN0/NFF1Z5 Mill Creek, WA 98082 TEL. 425.408.2748 challenge a �ucce5e -civil a atructurel FAX. 425.954.7539 info@cs2engineers.com Wood Beam DESCRIPTION: Deck joist (2x8 @ 16" o.c.) CODE REFERENCES Project Title: Engineer: Project ID: Project Descr: Printed: 27 SEP 2021, 5:27PM File: 2125 EnerCalc.ec6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2018 Material Properties Analysis Method: Allowable Stress Design Fb + 850 psi E: Modulus of Elasticity Load Combination iBC 2018 Fb - 850 psi Ebend- xx 1300 ksi Fc - Prll 1300 psi Eminbend - xx 470 ksi Wood Species Hem -Fir Fc - Perp 405 psi Wood Grade : No.2 Fv 150 psi Ft 525 psi Density 26.84pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling Repetitive Member Stress Increase D(0.015996) L(0.07998) Span = 9.0 f: Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.0120, L = 0.060 ksf, Tributary Width =1.333 ft DESIGN SUMMARY 514INT11191 Maximum Bending Stress Ratio = 0.757 1 Maximum Shear Stress Ratio = 0.345 : 1 Section used for this span 2x8 Section used for this span 2x8 fb: Actual = 887.41 psi fv: Actual = 51.74 psi Fb: Allowable = 1,173.00psi Fv: Allowable = 150.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 4.500ft Location of maximum on span = 8.409 ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.192 in Ratio = 563>=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.230 in Ratio = 469>=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FIV C i C r C m C t C L M fb F'b V fv F'v D Only 0.00 0.00 0.00 0.00 Length = 9.0 ft 1 0.140 0.064 0.90 1.200 1.00 1.15 1.00 1.00 1.00 0.16 147.90 1055.70 0.06 8.62 135.00 +D+L 1.200 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 9.0 ft 1 0.757 0.345 1.00 1.200 1.00 1.15 1.00 1.00 1.00 0.97 887.41 1173.00 0.38 51.74 150.00 +D+0.750L 1.200 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 9.0 ft 1 0.479 0.218 1.25 1.200 1.00 1.15 1.00 1.00 1.00 0.77 702.53 1466.25 0.30 40.96 187.50 +0.60D 1.200 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 9.0 ft 1 0.047 0.022 1.60 1.200 1.00 1.15 1.00 1.00 1.00 0.10 88.74 1876.80 0.04 5.17 240.00 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. 'Y' Defl Location in Span +D+L 1 0.2301 4.533 0.0000 0.000 Page 3 of 21 P.O. Box 13423 Project Title: G52 ffN0/NPP1Z5 Mill Creek, WA 98082 Engineer: TEL.425.408.2748 Project ID: cnauenye :��e55 -� �n d atruarura� FAX. 425.954.7539 Project Descr: info@cs2engineers.com Printed: 27 SEP 2021, 5:27PM Wood Beam File: 2125 EnerCalc.ec6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 r.i DESCRIPTION: Deck joist (2x8 @ 16" o.c.) Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.432 0.432 Overall MINimum 0.360 0.360 D Only 0.072 0.072 +D+L 0.432 0.432 +D+0.750L 0.342 0.342 +0.60D 0.043 0.043 L Only 0.360 0.360 Page 4 of 21 SCE AMERICAN SOCIETY OF CIVIL ENGINEERS Address: 929 Cary Rd Edmonds, Washington 98020 ASCE 7 Hazards Report Standard: ASCE/SEI 7-16 Elevation: 18.23 ft (NAVD 88) Risk Category: II Latitude: 47.820886 Soil Class: D - Default (see Longitude:-122.374195 Section 11.4.3) ,lb ti Cable � r.' Area : / I: r.. - • -•fir ? Wind HarsNllE I ti ' yor ��5 r '— n�. hF. Hill Creek Lpr n•A' od I 'lilt• i 'I'� .(I �,� R oln ell C'ub Isn BIIr1k-- - - fry-! .Von Intl boob - L]kC . IPalest � ' SWtomch Parr I Kirkland lab Results: Wind Speed: 98 Vmph 10-year MRI 67 Vmph 25-year MRI 74 Vmph 50-year MRI 78 Vmph 100-year MRI 83 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1 B and Figs. CC.2-1—CC.2-4, and Section 26.5.2 Date Accessed: Mon Sep 27 2021 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane -prone region as defined in ASCE/SEI 7-16 Section 26.2. https://asce7hazardtool.online/ Page 1 of 5 Mon Sep 27 2021 Page 5 of 21 -ASCE® AMERICAN SOCIETY OF CIVIL ENGINEERS Seismic Site Soil Class: D - Default (see Section 11.4.3) Results: Ss : 1.291 Sol N/A S, 0.455 TL 6 Fa 1.2 PGA: 0.55 FV N/A PGA m : 0.66 Sans : 1.55 FPGA 1.2 SM, N/A le 1 SIDS 1.033 Cv 1.358 Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Data Accessed: Mon Sep 27 2021 Date Source: USGS Seismic Design Maps https://asce7hazardtool.onIine/ Page 2 of 5 Mon Sep 27 2021 Page 6 of 21 -ASCE® AMERICAN SOCIETY OF CIVIL ENGINEERS Snow Results: Elevation: Data Source: Date Accessed: Mon Sep 27 2021 In "Case Study" areas, site -specific case studies are required to establish ground snow loads. Extreme local variations in ground snow loads in these areas preclude mapping at this scale. Ground snow load determination for such sites shall be based on an extreme value statistical analysis of data available in the vicinity of the site using a value with a 2 percent annual probability of being exceeded (50-year mean recurrence interval). Site is outside ASCE/SEI 7-16, Table 7.2-5 boundaries. For ground snow loads in this area, see SEAW Snow Load Analysis for Washington, 2nd Ed. (1995). Structural Engineers Association of Washington, Seattle, WA. Statutory requirements of the Authority Having Jurisdiction are not included. https://asce7hazardtool.onIine/ Page 3 of 5 Mon Sep 27 2021 Page 7 of 21 -ASCE® AMERICAN SOCIETY OF CIVIL ENGINEERS Flood Results: Flood Zone Categorization: X (unshaded) Base Flood Elevation: Data Source: FEMA National Flood Hazard Layer - Effective Flood Hazard Layer for US, where modernized (htti2s://msc.fema.gov/portal/search) Date Accessed: Mon Sep 27 2021 FIRM Panel: If available, download FIRM panel here Insurance Study Note: Download FEMA Flood Insurance Study for this area here Tsunami Results: Tsunami: Not in mapped tsunami design zone. Data Source: ASCE Tsunami Design Geodatabase Date Accessed: Mon Sep 27 2021 https://asce7hazardtool.onIine/ Page 4 of 5 Mon Sep 27 2021 Page 8 of 21 -ASCE® ZERICAN SOCIETY OF CIVIL ENGINEERS The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided "as is" and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third -party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third -parry content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. https://asce7hazardtool.online/ Page 5 of 5 Mon Sep 27 2021 Page 9 of 21 Project: Strickland Residence Deck Replacement G52 FNG/NMFRS Client: Owner Job No.: 2125 Civil e Structural By: S. Cho Date: 9/27/21 Challenge S Success Subiect: Desian Calculations Paae: IBC 2018 & ASCE 7-16 Seismic Loadi Seismic Ground Motion Value Per USGS Seismic Data SS = 1.291 g SMS = 1.033 g Site Class = D (Per USGS) S, = 0.455 g SMi = N/A g Calculate Seismic Design Base Shear Structure Height, hh, (ft) = 10 SoS = 2/3 SMs = 0.689 (per USGS) Spy = 2/3 SM, = N/A (per USGS) Risk Category= Standard -Occupancy Buildings = II Seismic Design Category per SDS = D Occupancy Importance Factor, IE = 1 (ASCE 7, Table 11.5.1) Response Modification Factor, R = 1.5 (ASCE 7, Table 12.2-1) Building Period Coefficient, Ct = 0.02 (ASCE 7, Table 12.8-2) T = C, x (h )3" = 0.112 (ASCE 7, Eq 12.8-7) TL = long -period transaction = 6 (ASCE 7, Fig 22-15) CS = Sos/(R/IE) = 0.459 (ASCE 7, Eq 12.8-2) But need not exceed: CS = Spy/[T(R/IE)j = N/A (ASCE 7, Eq 12.8-3) But not less than: CS = 0.44SDSIE ;(not less than 0.01) = 0.030 (ASCE 7, Eq 12.8-5) Cs = 0.5S,/(R/IE) (if S, > or = 0.6g) = N/A (ASCE 7, Eq 12.8-6) Seismic Base Shear, Vs = CsW, (kips) = 0.459 x Weight Calculate Seismic Force for Components (Per ASCE7-16 Chapter 131 Component amplification factor, ap Component Importance factor, Ip Component operating weight, WP Component response modification factor, RP Height of attachment / Mean roof height, z/h Seismic Design Force, Fp = (0.4aPS ,WP) (1+2xz/h) _ RP/IP 1 (ASCE 7, Table 13.5.1 & 13.6.1) 1 (ASCE 7, Section 13.3) WP (lb) 2.5 (ASCE 7, Table 13.5.1 & 13.6.1) 1 (z/h need not exceed 1.0) 0.331 WP (Eq. 13.3-1) Max. seismic design force, Fpmax = 1.6SpslpWp = 1.102 WP (Eq. 13.3-2) Min. seismic design force, Fpm;,, = 0.3SpslpWp = 0.207 WP (Eq. 13.3-3) Seismic Design Force, Fp = 0.331 WP TEL: (425) 408-2748 P.O. Box 13423 Page 10 of 21 FAX: (425) 954-7539 Mill Creek, WA 98082 info@cs2engineers.com WEST ELEVATION 1N =- 6'-0 1/16" 7'-3 I/9"- DBL1X10 N286TR TREATED (51DI13M8B1R TREATED STRINGER 4U #2flBTR TREATED BEAM TYP. 3-0 1/2" ' LTT 19 TIES ON ENDS OF DECK / OFHOUAG INTO EXIG RIM JOIST OF HOUSE PROFME]WANE PROOF MEMRRANE-TILE APPRO%KB 50FT -TT 19 TIES ON ENDS OF DECK - 1QW-AG INTO EXTG RIM JOIST OFHODSE 7�L L FE] E [] F] P Area = FRAMING / FOUNDATION PLAN Lateral force calculation: Weight of deck = 344.5 ft2 x 12 psf = 4,134 Ibs Seismic force (V) = CSW = (0.459 x 4,134 Ibs) = 1,898 Ibs Longitudinal directional force = 1,898 Ibs / 2 = 949 Ibs Transverse directional force = 1,898 Ibs --> Deck tension tie (DTT1Z) requirement = 1,898 Ibs / 750 Ibs = 2.5 --> Use minimum of (3) DTT1Z Tension tie (see reference) L719 TIES ON ENS F,DECN- 1R'%SRAG INTO RIM JOIST OF HOUSE 949 Ibs %10-STRTREATED 2X8 JOIST 16.00 TYPICAL. 8-10 1/2" EXISTING DECKTO REMAIN 949 I bs (4) "DTT1Z" Tension Tie equally spaced. Mi.n 24" from end. c 0 a� c -C- CD Tn U Co W Or CDC 1..1..E LU w CIO CU U �j vJ BY: CC DATE: -21 PERMIT SET A2 Page 11 of 21 DTT1z G" n m. ` Cogs aI side-moum 1 installation / I a" min. I Do notover-driwe anchoring screw Predrill 44ie-diameter hole for fully threaded / lag screw. Predrilling not / required with / Strong -Drive SDVVH Timber -Hex HDG Screw. \ (Siding not shown for clarity) / \ Pi.ureA / / B'8"TILE OVER WATER PROOF MEMBRA =L45HING 1-118"T&O UNDERIAYMENT SCHULTERTU EDGE COW NOUS I ' JOIST 16 CTYPI —2XB PT BRIDGING TYP. IP EDGE Fvsxwc TYPPT %13 FASCIASOS1B'X4'GALVIAG13 LIOR TTYPIO PT RFAM 1 SIMPSON CC048SDS] S AT EACH POST SIMPSON -a L11S]SZ JOIST HANGAR TYP. USE END COLUMN CAP AT EACH END. PXBPTRIMJOISTATTACH WI #12 CONSTRUCTION SCREWS @8" OC STAGER TOP BBTM WI 2 Xd BAR EA DIRECTION SECTION 1 ENLARGED STAIR ELEVATIOM CEDAR PORT 0 W fn U C6 Cll ui N o Cll F- LU ry w ICU C 0 Co Co Y C U 0 VJ 04 0') BY: CC GATE: —21 PERMIT SET A3 Page 12 of 21 TECHNICAL BULLETIN Allowable Loads Anchor Allowable Tension Load (lb.) (160) Dry Wet Model No. Diameter Fasteners or Type DF/SP SPF/HF DF/SP SPF/HF %11 (6) SD #9 x 1 Y2" 840 840 840 755 (6)10d x 1 Y2" 910 6404 795 6404 DTT1 Z 3/a" or SDWHS (8)10d x 1 Y2" 910 850 910 850 DTT2Z/DTT2SS 13/is" Y2" (8) SDS 1/4" x 1Y2" 1 1,825 1,800 1,825 1,615 1. Allowable loads have been increased 60% for short-term loading with no further increase allowed. 2. Dry values are applicable to installations into wood with a moisture content that does not exceed 19%. 3. Wet values are applicable to installations into wood with a moisture content greater than 19% at time of installation or in service. Values include an NDS wet service factor for the fasteners. 4. DTT1Z installations with allowable loads below 750 Ib. do not satisfy the 2015/2018 IRC requirements for deck -to -house lateral load connections. 5. DTT1Z installed with the Strong -Drive® SDWH Timber -Hex HDG screw with a min. of 3" thread penetration achieves the lesser of the table load or 855 lb. SDWH installed with 3" of thread penetration into dry lumber has an allowable withdrawal load (160) of 1,380 lb. into SP, 1,225 lb. into DF and 1,020 Ib. into SPF/HF. 6. Load values are valid if the product is flush with the end of the framing member or installed away from the end. 7. Fasteners: SD #9 x 11/2" (model SD9112) = 0.131" dia. x 1'/2", 10d x 11/2' = 0.148" dia. x 11/2" long. Conditions Not Shown in the IRC DTT1Z DTT2Z The IRC details describe particular methods that are appoved and do not represent all common framing conditions. When these are encountered, alternate methods of construction may need to be approved by the building official to ensure they satisfy the intent of the code and are at least equivalent to the prescribed method. Several alternate construction methods are shown here. DTT1Z --------------- 3" min. Optional side -mount o installation i 3" min. 1�' 11 11 a 4 a DTT1Z Do not over -drive anchoring screw Predrill 3/1s"-diameter hole for fully threaded lag screw. Predrilling not required with Strong -Drive SDWH Timber -Hex HDG screw. (Siding not shown for clarity) Figure 4 DTT1 Z — 750 lb. Assembly Condition 1 — Holdown Cannot Be Installed Flush with Wall Sheathing Unlike some holdowns, the DTT1Z seat is not required to bear on sheathing or framing and can be installed away from the wall to account for non-structural siding, joist hanger interference or other conditions. Longer screw anchors may be required to ensure a minimum of 3" thread penetration by a fully threaded lag screw or Strong -Drive SDWH Timber -Hex HDG screw into the wall framing. Condition 2 — Top of Wall Plate Does Not Align with Bottom of Deck Joist The 2015/2018 IRC detail shows a holdown installed on the bottom of the joist. However, the DTT1 Z was tested and developed using 11/2" fasteners into either the narrow edge or wide face of a 2x member, allowing the DTT1 Z to be installed at any location along the depth of the joist. m a Y U 0 U H a 0 U m 2 Q E Cn 0 0 P.O. Box 13423 - G52 ffN0/NFF1Z5 Mill Creek, WA 98082 TEL. 425.408.2748 challenge a �ucce5e -civil a atructurel FAX. 425.954.7539 info@cs2engineers.com Wood Beam DESCRIPTION: Deck joist (2x8 @ 16" o.c.) CODE REFERENCES Project Title: Engineer: Project ID: Project Descr: Printed: 27 SEP 2021, 5:27PM File: 2125 EnerCalc.ec6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2018 Material Properties Analysis Method: Allowable Stress Design Fb + 850 psi E: Modulus of Elasticity Load Combination iBC 2018 Fb - 850 psi Ebend- xx 1300 ksi Fc - Prll 1300 psi Eminbend - xx 470 ksi Wood Species Hem -Fir Fc - Perp 405 psi Wood Grade : No.2 Fv 150 psi Ft 525 psi Density 26.84pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling Repetitive Member Stress Increase D(0.015996) L(0.07998) Span = 9.0 f: Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.0120, L = 0.060 ksf, Tributary Width =1.333 ft DESIGN SUMMARY 514INT11191 Maximum Bending Stress Ratio = 0.757 1 Maximum Shear Stress Ratio = 0.345 : 1 Section used for this span 2x8 Section used for this span 2x8 fb: Actual = 887.41 psi fv: Actual = 51.74 psi Fb: Allowable = 1,173.00psi Fv: Allowable = 150.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 4.500ft Location of maximum on span = 8.409 ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.192 in Ratio = 563>=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.230 in Ratio = 469>=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FIV C i C r C m C t C L M fb F'b V fv F'v D Only 0.00 0.00 0.00 0.00 Length = 9.0 ft 1 0.140 0.064 0.90 1.200 1.00 1.15 1.00 1.00 1.00 0.16 147.90 1055.70 0.06 8.62 135.00 +D+L 1.200 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 9.0 ft 1 0.757 0.345 1.00 1.200 1.00 1.15 1.00 1.00 1.00 0.97 887.41 1173.00 0.38 51.74 150.00 +D+0.750L 1.200 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 9.0 ft 1 0.479 0.218 1.25 1.200 1.00 1.15 1.00 1.00 1.00 0.77 702.53 1466.25 0.30 40.96 187.50 +0.60D 1.200 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 9.0 ft 1 0.047 0.022 1.60 1.200 1.00 1.15 1.00 1.00 1.00 0.10 88.74 1876.80 0.04 5.17 240.00 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. 'Y' Defl Location in Span +D+L 1 0.2301 4.533 0.0000 0.000 Page 14 of 21 P.O. Box 13423 Project Title: G52 ffN0/NPP1Z5 Mill Creek, WA 98082 Engineer: TEL.425.408.2748 Project ID: cnauenye :��e55 -� �n d atruarura� FAX. 425.954.7539 Project Descr: info@cs2engineers.com Printed: 27 SEP 2021, 5:27PM Wood Beam File: 2125 EnerCalc.ec6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 r.i DESCRIPTION: Deck joist (2x8 @ 16" o.c.) Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.432 0.432 Overall MINimum 0.360 0.360 D Only 0.072 0.072 +D+L 0.432 0.432 +D+0.750L 0.342 0.342 +0.60D 0.043 0.043 L Only 0.360 0.360 Page 15 of 21 P.O. Box 13423 - G52 ffN0/NFF1Z5 Mill Creek, WA 98082 TEL. 425.408.2748 challenge a �ucce5e -civil a atructurel FAX. 425.954.7539 info@cs2engineers.com Wood Beam DESCRIPTION: Deck Beam (410 @ 8'-0" o.c.) CODE REFERENCES Project Title: Engineer: Project ID: Project Descr: Printed: 27 SEP 2021, 6:27PM File: 2125 EnerCalc.ec6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2018 Material Properties Analysis Method: Allowable Stress Design Fb + 850.0 psi E: Modulus of Elasticity Load Combination iBC 2018 Fb - 850.0 psi Ebend- xx 1,300.0 ksi Fc - Prll 1,300.0 psi Eminbend - xx 470.0 ksi Wood Species Hem -Fir Fc - Perp 405.0 psi Wood Grade : No.2 Fv 150.0 psi Ft 525.0 psi Density 26.840 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling 4x10 Span = 8.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.0120, L = 0.060 ksf, Tributary Width = 4.50 ft DESIGN SUMMARY • Maximum Bending Stress Ratio = 0.611: 1 Maximum Shear Stress Ratio = 0.324 : 1 Section used for this span 4x10 Section used for this span 4x10 fb: Actual = 623.18psi fv: Actual = 48.65 psi Fb: Allowable = 1,020.00psi Fv: Allowable = 150.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 4.000ft Location of maximum on span = 7.241 ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.083 in Ratio = 1151 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.100 in Ratio = 959 >=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C i Cr C m C t C L M fb F'b V fv F'v D Only 0.00 0.00 0.00 0.00 Length = 8.0 ft 1 0.113 0.060 0.90 1.200 1.00 1.00 1.00 1.00 1.00 0.43 103.86 918.00 0.18 8.11 135.00 +D+L 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 8.0 ft 1 0.611 0.324 1.00 1.200 1.00 1.00 1.00 1.00 1.00 2.59 623.18 1020.00 1.05 48.65 150.00 +D+0.750L 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 8.0 ft 1 0.387 0.205 1.25 1.200 1.00 1.00 1.00 1.00 1.00 2.05 493.35 1275.00 0.83 38.52 187.50 +0.60D 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 8.0 ft 1 0.038 0.020 1.60 1.200 1.00 1.00 1.00 1.00 1.00 0.26 62.32 1632.00 0.11 4.87 240.00 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. °+° Defl Location in Span +D+L 1 0.1001 4.029 0.0000 0.000 Page 16 of 21 P.O. Box 13423 Project Title: G52 ffN0/NPP1Z5 Mill Creek, WA 98082 Engineer: TEL.425.408.2748 Project ID: cnauenye :��e55 -� �n d atruarura� FAX. 425.954.7539 Project Descr: info@cs2engineers.com Printed: 27 SEP 2021, 6:27PM Wood Beam File: 2125 EnerCalc.ec6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 DESCRIPTION: Deck Beam (410 @ 8'-0" o.c.) Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 1.296 1.296 Overall MINimum 1.080 1.080 D Only 0.216 0.216 +D+L 1.296 1.296 +D+0.750L 1.026 1.026 +0.60D 0.130 0.130 L Only 1.080 1.080 Footing design load = 2D + 2L = 432 Ibs + 2,160 Ibs Page 17 of 21 P.O. Box 13423 - G52 ffN0/NFF1Z5 Mill Creek, WA 98082 TEL. 425.408.2748 challenge a �ucce5e —civil a atructurel FAX. 425.954.7539 info@cs2engineers.com General Footing DESCRIPTION: Footing Design Code References Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16 Load Combinations Used : IBC 2018 General Information Project Title: Engineer: Project ID: Project Descr: Printed: 27 SEP 2021, 6:29PM File: 2125 EnerCalc.ec6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 Material Properties Soil Design Values fc : Concrete 28 day strength = 3.0 ksi Allowable Soil Bearing = 1.50 ksf fy : Rebar Yield = 60.0 ksi Increase Bearing By Footing Weight = No Ec : Concrete Elastic Modulus = 3,122.0 ksi Soil Passive Resistance (for Sliding) = 250.0 pcf Concrete Density = 145.0 pcf Soil/Concrete Friction Coeff. = 0.30 cp Values Flexure = 0.90 Shear = 0.750 Increases based on footing Depth Analysis Settings Footing base depth below soil surface = 1.50 ft Min Steel % Bending Reinf. = Allow press. increase per foot of depth = ksf Min Allow % Temp Reinf. = 0.00180 when footing base is below = ft Min. Overturning Safety Factor = 1.0 : 1 Min. Sliding Safety Factor = 1.0 : 1 Increases based on footing plan dimension Add Ftg Wt for Soil Pressure Yes Allowable pressure increase per foot of depth Use ftg wt for stability, moments & shears Yes = ksf Add Pedestal Wt for Soil Pressure Yes when max. length or width is greater than - - ft Use Pedestal wt for stability, mom & shear Yes Dimensions Width parallel to X-X Axis = 1.5 ft Length parallel to Z-Z Axis = 1.50 ft Footing Thickness = 8.0 in Pedestal dimensions... px : parallel to X-X Axis = 8.0 in pz : parallel to Z-Z Axis = 8.0 in Height - 8.0 in Rebar Centerline to Edge of Concrete... at Bottom of footing = 3.0 in Reinforcing Bars parallel to X-X Axis Number of Bars - 2 Reinforcing Bar Size = # 4 Bars parallel to Z-Z Axis Number of Bars = 2 Reinforcing Bar Size = # 4 Bandwidth Distribution Check (ACI 15.4.4.2) Direction Requiring Closer Separation n/a # Bars required within zone n/a # Bars required on each side of zone n/a Applied Loads D P : Column Load = 0.4320 OB : Overburden = M-xx M-zz V-x V-z FA X-X Section Looking to +Z Lr L S W 2.160 Z-#Gears Z-Z Sedion Looking m tX E H k ksf k-ft k-ft k k Page 18 of 21 P.O. Box 13423 G52 ffN0/NPP1Z5 Mill Creek, WA 98082 Project Title: Engineer: TEL.425.408.2748 Project ID: cnauenye :��e55 -� �n d atruarura� FAX. 425.954.7539 Project Descr: info@cs2engineers.com Printed: 27 SEP 2021, 6:29PM General Footing g File:2125 EnerCalc.ec6 ` Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 DESCRIPTION: Footing Design DESIGN SUMMARY - • Min. Ratio Item Applied Capacity Governing Load Combination PASS 0.8940 Soil Bearing 1.341 ksf 1.50 ksf +D+L about Z-Z axis PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding PASS n/a Uplift 0.0 k 0.0 k No Uplift PASS 0.02698 Z Flexure (+X) 0.1534 k-ft/ft 5.686 k-ft/ft +1.20D+1.60L PASS 0.02698 Z Flexure (-X) 0.1534 k-ft/ft 5.686 k-ft/ft +1.20D+1.60L PASS 0.02698 X Flexure (+Z) 0.1534 k-ft/ft 5.686 k-ft/ft +1.20D+1.60L PASS 0.02698 X Flexure (-Z) 0.1534 k-ft/ft 5.686 k-ft/ft +1.20D+1.60L PASS n/a 1-way Shear (+X) 0.0 psi 82.158 psi n/a PASS 0.0 1-way Shear (-X) 0.0 psi 0.0 psi n/a PASS n/a 1-way Shear (+Z) 0.0 psi 82.158 psi n/a PASS n/a 1-way Shear (-Z) 0.0 psi 82.158 psi n/a PASS n/a 2-way Punching 7.367 psi 82.158 psi +1.20D+1.60L Detailed Results Soil Bearing Rotation Axis & Xecc Zecc Actual Soil Bearing Stress @ Location Actual 1 Allow Load Combination... Gross Allowable (in) Bottom, -Z Top, +Z Left, -X Right, +X Ratio X-X, D Only 1.50 n/a 0.0 0.3813 0.3813 n/a n/a 0.254 X-X, +D+L 1.50 n/a 0.0 1.341 1.341 n/a n/a 0.894 X-X, +D+0.750L 1.50 n/a 0.0 1.101 1.101 n/a n/a 0.734 X-X, +0.60D 1.50 n/a 0.0 0.2288 0.2288 n/a n/a 0.153 Z-Z, D Only 1.50 0.0 n/a n/a n/a 0.3813 0.3813 0.254 Z-Z, +D+L 1.50 0.0 n/a n/a n/a 1.341 1.341 0.894 Z-Z, +D+0.750L 1.50 0.0 n/a n/a n/a 1.101 1.101 0.734 Z-Z, +0.60D 1.50 0.0 n/a n/a n/a 0.2288 0.2288 0,153 Overturning Stability Rotation Axis & Load Combination... Overturning Moment Resisting Moment Stability Ratio Status Footing Has NO Overturning Sliding Stability All units k Force Application Axis Load Combination... Sliding Force Resisting Force Stability Ratio Status Footing Has NO Sliding Footing Flexure Flexure Axis &Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status k-ft Surface inA2 inA2 in2 k-ft X-X, +1.40D 0.02345 +Z Bottom 0.1728 Min Temp % 0.2667 5.686 OK X-X, +1.40D 0.02345 -Z Bottom 0.1728 Min Temp % 0.2667 5.686 OK X-X, +1.20D+1.60L 0.1534 +Z Bottom 0.1728 Min Temp % 0.2667 5.686 OK X-X, +1.20D+1.60L 0.1534 -Z Bottom 0.1728 Min Temp % 0.2667 5.686 OK X-X, +1.20D+0.50L 0.06177 +Z Bottom 0.1728 Min Temp % 0.2667 5.686 OK X-X, +1.20D+0.50L 0.06177 -Z Bottom 0.1728 Min Temp % 0.2667 5.686 OK X-X, +1.201) 0.02010 +Z Bottom 0.1728 Min Temp % 0.2667 5.686 OK X-X, +1.20D 0.02010 -Z Bottom 0.1728 Min Temp % 0.2667 5.686 OK X-X, +0.90D 0.01508 +Z Bottom 0.1728 Min Temp % 0.2667 5.686 OK X-X, +0.901) 0.01508 -Z Bottom 0.1728 Min Temp % 0.2667 5.686 OK Z-Z, +1.40D 0.02345 -X Bottom 0.1728 Min Temp % 0.2667 5.686 OK Z-Z, +1.40D 0.02345 +X Bottom 0.1728 Min Temp % 0.2667 5.686 OK Z-Z, +1.20D+1.60L 0.1534 -X Bottom 0.1728 Min Temp % 0.2667 5.686 OK Z-Z, +1.20D+1.60L 0.1534 +X Bottom 0.1728 Min Temp % 0.2667 5.686 OK Z-Z, +1.20D+0.50L 0.06177 -X Bottom 0.1728 Min Temp % 0.2667 5.686 OK Z-Z, +1.20D+0.50L 0.06177 +X Bottom 0.1728 Min Temp % 0.2667 5.686 OK Page 19 of 21 P.O. Box 13423 G52 FNG/NFgR5 Mill Creek, WA 98082 Project Title: Engineer: TEL.425.408.2748 Project ID: - �h�nenge :��e55 - oiv a �erU�t�rai FAX. 425.954.7539 Project Descr: info@cs2engineers.com Printed: 27 SEP 2021, 6:29PM General FootingFile:2125 EnerCalc.ec6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 i.i DESCRIPTION: Footing Design Footing Flexure Flexure Axis &Load Combination Mu Side Tension As Req'd Gvm. As Actual As Phi*Mn Status k-ft Surface in^2 in^2 in^2 k-ft Z-Z, +1.20D 0.02010 -X Bottom 0.1728 Min Temp % 0.2667 5.686 OK Z-Z, +1.20D 0.02010 +X Bottom 0.1728 Min Temp % 0.2667 5.686 OK Z-Z, +0.90D 0.01508 -X Bottom 0.1728 Min Temp % 0.2667 5.686 OK Z-Z, +0.90D 0.01508 +X Bottom 0.1728 Min Temp % 0.2667 5.686 OK One Way Shear Load Combination... Vu @ -X Vu @ +X Vu @ -Z Vu @ +Z Vu:Max Phi Vn Vu 1 Phi*Vn Status +1.401) 0.00 psi 0.00 psi 0.00 psi 0.00 psi 0.00 psi 82.16 psi 0.00 OK +1.20D+1.60L 0.00 psi 0.00 psi 0.00 psi 0.00 psi 0.00 psi 82.16 psi 0.00 OK +1.20D+0.50L 0.00 psi 0.00 psi 0.00 psi 0.00 psi 0.00 psi 82.16 psi 0.00 OK +1.20D 0.00 psi 0.00 psi 0.00 psi 0.00 psi 0.00 psi 82.16 psi 0.00 OK +0.90D 0.00 psi 0.00 psi 0.00 psi 0.00 psi 0.00 psi 82.16 psi 0.00 OK Two -Way "Punching" Shear All units k Load Combination... Vu Phi*Vn Vu 1 Phi*Vn Status +1.40D 1.13 psi 164.32psi 0.006853 OK +1.20D+1.60L 7.37 psi 164.32psi 0.04483 OK +1.20D+0.50L 2.97 psi 164.32psi 0.01805 OK +1.201) 0.97 psi 164.32psi 0.005874 OK +0.90D 0.72 psi 164.32psi 0.004405 OK Page 20 of 21 Project: Strickland Residence Deck Replacement Location: Edmonds, WA Date: September 27, 2021 Prepared By: S. Cho CS2 No: 2125 Page Appendix TEL: (425) 408-2748 P.O. Box 13423 Page 21 of 21 FAX: (425) 954-7539 Mill Creek, WA 98082 info@cs2engineers.com W PDS Property Report Snohomish County Planning & Development Services Report Generated On: 912712021 9:48:56 AM Snohomish County shall have no liability for the data or lack thereof, or any decisions made, or action not taken in reliance upon any of the information provided in this report. Please consult PDS Staff for the most current information. This report is subject to the disclaimer as noted on the bottom of each page and at the end of the report.* Aerial LOCATION Site Address: 929 CARY RD City: EDMONDS ZIP Code: 98020-2651 Tax Parcel: 27032400210800 Quarter Section T&R: NW 24 T27N R 3E ASSESSOR ♦' NOrth sfream Lnz Dr,% Q' 00 Tidelands p4ge d �n #1 Park f �n Puget Sound Puget Dr Puget Way Melody Ln �a Hindley Ln 00 z o ere Dr s 0) > o < > R m fD U Edmonds Z Vicinity Latitude / Longitude: Latitude = 47.821015 (NAD83) Longitude =-122.373469 WA State Plane North: X = 1,262,083.42 (NAD83, US Feet) Y = 303,264.60 Owner Name: STRICKLAND R T Gross Size (Acres): 3.33 Land Value: $3,978,000 Taxpayer of Record: STRICKLAND R T Improvement Value: $1,018,700 Total Value: $4,996,700 Use Code: Property Account 940 Open Space General RCW 84.34 Assessor's Tax Information Summary: Tax Year: 2021 Permit Information: Permit History Assessment Date: 01/01/2020 ADMINISTRATIVE Land Use Jurisdiction: City of Edmonds Tribal Lands Status: Non -tribal land Tribal Lands Name: Non -tribal land Council District: County Council District 3 Fire District: Not in a fire district Fire Authority: Not in a Fire Authority area Park District: Not in a park district Park Service Area: Nakeeta Beach Tax Parcel: 27032400210800 School District: Edmonds School District 15 Sewer District: Not in a sewer district Water District: Not in a water district Water Provider (CWSP): City of Edmonds Water System Drainage District: Not in a drainage district Diking District: Not in a diking district Flood Control District: Not in a flood control district Data Compiled On: 0912612021 *All information contained in this report is subject to the data disclaimer, as stated on the final page. Page 1 13 I�ed Zoning: ity of Edmonds Y /A Future Land Use Zoning PLANNING Future Land Use (FLU): CITY Conservation Easements No Data FLU Description: No -Shooting Area: Inside a No -shooting Area (SCC 10.12) Incorporated City Lot Status: Unconfirmed Zoning: SCC 30.23.040 (22) Minimum Lot Size does not apply CITY Applies: (per SCC 30.23.040(22)) Official Zoning and other map products Transportation Services F Zoning Description: Area: City TDR Sending Area: Not in a TDR Sending area TDR Receiving Area: Not in a TDR Receiving area Urban Growth Area (UGA): Southwest County UGA Mineral Resource Area: Not in an Mineral Resource area Municipal UGA: Mineral Resource Name: Not in a mineral resource overlay EDMONDS area Transportation ILA: Shoreline Management Not in an Transportation Interlocal Area: Not in a Shoreline Management Agreement Area Area Snow Load Factor: 0.0489999987185 Critical Area Site Plan No Critical Area Site Plan Present (CASP): Snow Load: View CASP information, if applicable. 25.00 Ibs/sq ft NOTIFICATION Lahar Volcanic Notice Agriculture Notification: Not within an agriculture (200 ft.): Not in a lahar hazard area Area: notification area Commercial Forest Paine Field Airport: Not within 500 ft of a commercial Not within 20,000 ft of Paine Field Notice (500 ft.): forest Airpark: Mineral Resource No airparks within 2500 ft Notice (2,000 ft.): Not within 2,000 ft of a Mineral Airport Compatibility Not within an airport compatibility Resource Overlay area Area: area Airport Influence Area: Not within an airport influence area Tax Parcel: 27032400210800 Data Compiled On: 0912612021 *All information contained in this report is subject to the data disclaimer, as stated on the final page. Page 2 13 CRITICAL AND PHYSICAL Watershed: Cedar-Sammamish watershed Aquifer Sensitivity: Low Aquifer Sensitivity Elevation: Approximately 2.0 to 30.0 ft (NAVD88, US Feet) Basin: Puget Sound Sub -basin: Puget Sound Drainage sub -basin Water Resource Inventory WRIA 8 Area (WRIA): Hydric Soils: No hydric soils Hydric soils present Flood Hazard Area: A portion of the parcel is inside the flood hazard area Sole Source Aquifer: Not in a sole source aquifer 100 Year Flood Plain: Puget Sound Critical Aquifer Recharge Area: Not in a critical aquifer recharge area Pipelines: No petroleum pipelines within 1,000 feet Geology: preFraser nonglacial - Olympia (Erodible Surface) gravel/Whidbey fm : Water WALKABLE PUBLIC AMENITIES Parks Within 1/2 Mile: Tidelands #1 National Wetlands Inventory: Estuarine and Marine Wetland Freshwater Emergent Wetland PDS Wetlands Inventory: Inventoried Steep Slopes (> 33%): Steep slopes present Landslide Hazard Area: Not within a known landslide and outside the modeled LHA area More Information: SCC 30.62B.340 Mine Hazard: No mines within 200 feet Levees: No levees within 1,000 feet Levees Source: No levee on the property Soil Type: Bus Stops Within 1/2 Mile: 3rd Ave N & 4th Ave N 3rd Ave N & Giltner Ln 3rd Ave N & Daley St 9th Ave N & Hindley Ln 3rd Ave N & 4th Ave N ALDERWOOD-URBAN LAND COMPLEX, 2 TO 8 PERCENT SLOPES:EVERETT GRAVELLY SANDY LOAM, 0 TO 8 PERCENT SLOPES: WATER Schools Within 1/2 Mile: Edmonds Elementary School DATA DISCLAIMER All maps, data, and information set forth herein ("Data"), are for illustrative purposes only and are not to be considered an official citation to, or representation of, the Snohomish County Code. Ammendments and updates to the Data, together with other applicable County Code provisions, may apply wheich are not depicted herein. Snohomish County makes no representation or warranty concerning the content, accuracy, currency, completeness or quality of the Data contained herein and expressly disclaims any warranty of merchantability or fitness for any particular purpose. All persons accessing or otherwise using this Data assume all responsibility for use thereof and agree to hold Snohomish County harmless from and against any damages, loss, claim or liability arising out of any error, defect or omission contained within said Data. Washington State Law, Ch. 42.56 RCW, prohibits state and local agencies from providing access to lists of individuals intended for use for commercial purposes and, thus, no commercial use may be made of any Data comprising lists of individuals contained herein. Snohomish County Planning and Development Services 3000 Rockefeller Avenue Everett, WA 98201 Phone: 425-388-3311 Customer Service Hours: Monday/Tuesday/Wednesday/Friday: 8:00 AM - 4:00 PM Thursday: 10:00 AM - 4:00 PM Walk-ins will be assisted on a first -come, first -served basis. Tax Parcel: 27032400210800 Data Compiled On: 0912612021 *All information contained in this report is subject to the data disclaimer, as stated on this page. Page 3 1 3