APPROVED PLN_BLD BLD2021-1665+Architectural_Plan+12.8.2021_12.43.59_PM+2560474BRUBAKER RESIDENC FOUNDATION REPAIR 9712 242ND PL SW EDMONDS, WA 98020 OWNER TERIANNE BRUBAKER P.O. BOX 745 DEER PARK, WA 99006 509.385.5292 BRUBAKER.TERIANNE@ GMAIL.COM CONSULTANTS STRUCTURAL ENGINEER CG ENGINEERING 250 4TH AVE S, SUITE 200 EDMONDS, WA 98020 425.778.8500 FAX 778.5536 CONTACT: GREG GUILLEN, PE, SE LEGAL DESCRIPTION FORSHEES FIRDALE VILLAGE 5 BLK 000 D-00 - LOT II PARCEL NUMBER 00450300001100 PROPERTY INFORMATION TOTAL LOT AREA = 9,583 SQFT EX BUILDING FOOTPRINT = 2,428 SQFT PROPOSED BUILDING FOOTPRINT = NOT TO CHANGE TOTAL IMPERVIOUS SURFACE = NOT TO CHANGE GEOTECHNICAL ENGINEER NELSON GEOTECHNICAL ASSOCIATES, INC 17311-135TH AVE NE, SUITE A-500 WOODINVILLE, WA 98072 425.486.1669 KHALED M. SHAWISH SCOPE OF WORK STABILIZE THE EXISTING CONCRETE FOUNDATION WITH 2"0 PIN PILES WHERE SETTLEMENT HAS OCCURRED. NOTE: SITE PLAN HAS BEEN PREPARED BASED ON FIELD MEASUREMENTS & COUNTY RECORDS & IS NOT A SURVEY, PROPERTY LINES ARE APPROXIMATE. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS & UTILITY LOCATIONS. SITE PLAN SCALE: 1" = 10' Nothing in the permit approval process shall be interpreted as allowing or permitting the maintenance of any currently existing illegal, nonconforming or unpermitted building, structure or site condition which is outside the scope of the permit application, regardless of whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of a separate enforcement action. APPROVED BY PLANNING 4 in 13 2022 10 0 5 10 9 s N 240th St SW 240th St SW F -0th Si SW 71 �o 240th PI SW 240th PI SW 240th PI SW o _ o �. 4z f < e o y 0 e � 9t 1p15W 241 st PISW 241 st PI SW N 241s 0 P S W s� o a 242.d PI SW o T. — D m— y�P 2431d PI SW o 243rd V1 Q D io Q w El � a f Z NW 203rd PI z � D D F NW 203rd St NW 203rd St NW 203rd St w i q f VICINITY MAP NTS = PROJECT SITE q6 20 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE Special Inspection required for: Pin Pile Installation Retro Fit anchorage City Of Edmonds Building Department Work r FOUNDATION REPAIR Address 9712 242ND PL SW ---------------------------------------- Owner BRUBAKER -------------------------- Approved Date ; 01/03/2022 Building Official Erg C'a4^te4' Permit Number BLD2021-1665 ---------------------------------------------- C C ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 Cs GUI WAs� Fes' O 25385 I S f� s`SIONAL �C} 121 W 21 Y Q DESIGN: BEL DRAWN: JCP CHECK: GAG JOB NO: 21363.10 DATE: 1 2/03/21 Q CL LLJ W Z RECEIVED 0 Dec 29 2021 CITY OF EDMONDS QDEPARTMENT DEVELOPMENT SERVICES Z D O L.L. LLJ 0 U 0 Z N L d 00 0 J LLJ o Q 3:: Z C):� Z Q N J LJ Y N Z m N O W � � 0 m O) L L1 (� SHEET: STRUCTURAL NOTES GENERAL SHORING NOTES IC.� (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) CODE ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION. SPECIFICATIONS AND STANDARDS WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. DESIGN LOADS DEAD LOADS: ROOF 12 PSF FLOOR 12 PSF LIVE LOADS: ROOF (SNOW LOAD) 25 PSF RESIDENTIAL 40 PSF DECKS 60 PSF (LIVE LOADS ARE REDUCED WHERE PERMISSIBLE PER IBC SECTION 1607.11). STATEMENT OF SPECIAL INSPECTIONS SPECIAL INSPECTIONS ARE REQUIRED AS INDICATED IN THE FOLLOWING TABLE. THE CONTRACTOR SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND OWNER PRIOR TO COMMENCEMENT OF WORK IN ACCORDANCE WITH SECTION 1704.4 OF THE IBC. STRUCTURAL OBSERVATION OF THE STRUCTURAL SYSTEM BY THE ENGINEER IS NOT REQUIRED. FREQUENCY AND DISTRIBUTION OF REPORTS - INSPECTION REPORTS SHALL BE PROVIDED FOR EACH DAY ON SITE BY SPECIAL INSPECTOR. STRUCTURAL OBSERVATION REPORTS SHALL BE PROVIDED AFTER EACH OBSERVATION. REPORTS SHALL BE DISTRIBUTED TO THE CONTRACTOR, ARCHITECT, ENGINEER AND BUILDING OFFICIAL. SPECIAL INSPECTION OPERATION CONT PERIODIC REMARKS SOILS PIPE PILING INSTALLATION X PILING REFUSAL VERIFICATION X CONCRETE ADHESIVE ANCHORS X IF REO'D NOTE: ALL ITEMS MARKED WITH AN "X" SHALL BE INSPECTED IN ACCORDANCE WITH IBC CHAPTER 17. SPECIAL INSPECTION SHALL BE PERFORMED BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE OWNER. THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL SHALL BE FURNISHED WITH COPIES OF ALL RESULTS. ANY INSPECTION FAILING TO MEET THE PROJECT SPECIFICATIONS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE DESIGN TEAM. FOUNDATIONS: PIN PILES SOILS REPORT: NOT AVAILABLE DURING DESIGN ALLOWABLE PILE CAPACITY: 6,000 LBS IMPORTED STRUCTURAL FILL AND BACKFILL MATERIAL SHOULD CONSIST OF CLEAN, WELL GRADED GRANULAR MATERIAL FREE OF DEBRIS OR ORGANICS WITH A MAXIMUM PARTICLE DIAMETER OF THREE INCHES AND NO MORE THAN 10% FINES (PASSING THE #200 SIEVE). FILL AND BACKFILL MATERIAL SHOULD BE PLACED IN LEVEL LIFTS NOT EXCEEDING TWELVE (12") INCHES IN LOOSE THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITY AS DETERMINED BY ASTM TEST METHOD D1557. 2"0 PIPE PILING INSTALLATION 2" XS PIPE SHALL CONFORM TO ASTM A53 GRADE A OR B, FY = 30 KSI (MIN) PILES SHALL BE DRIVEN THROUGH LOOSE MATERIAL & BEAR IN COMPETENT DENSE SOIL AS DETERMINED BY THE GEOTECHNICAL SPECIAL INSPECTOR. PILES SHALL HAVE A MINIMUM OVERALL EMBEDMENT OF 10 FEET OR AS DETERMINED ADEQUATE BY THE GEOTECHNICAL SPECIAL INSPECTOR. PILES SHALL NOT EXCEED A MAXIMUM EMBEDMENT DEPTH OF 30 FEET. PIPE PILING SHALL BE DRIVEN INTO THE SUBGRADE TO A POINT OF REFUSAL BY MEANS OF A PNEUMATIC HAMMER OR OTHER SIMILAR HYDRAULIC HAMMER SYSTEM. THE PNEUMATIC HAMMER SHOULD WEIGH AT LEAST 140 POUNDS. REFUSAL SHALL BE DEFINED AS 1" OR LESS OF PENETRATION DURING 1 MINUTE OF SUSTAINED DRIVING. PIPE SECTIONS SHALL BE CONNECTED WITH INTERNAL SLIP COUPLINGS. THE CONTRACTOR SHALL LOCATE AND PROTECT ALL UTILITIES DURING CONSTRUCTION AND SHALL CONTACT THE UNDERGROUND UTILITIES LOCATION SERVICE (1-800-424-5555) AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY ALL UTILITIES WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THESE DRAWINGS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY AND ALL DAMAGE TO UNDERGROUND UTILITIES RESULTING FROM THEIR OPERATION. CONCRETE ALL CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED, AND PLACED IN ACCORDANCE WITH CHAPTER 26 OF ACI 318 AND THE AMERICAN CONCRETE INSTITUTE'S SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301). ALL CONCRETE SHALL BE STONE -AGGREGATE CONCRETE HAVING A UNIT WEIGHT OF APPROXIMATELY 150 POUNDS PER CUBIC FOOT. CONCRETE STRENGTHS AT 28 DAYS (fc) AND MIX CRITERIA SHALL BE AS FOLLOWS: MAXIMUM MIN CEMENT TYPE OF CONSTRUCTION f'c* WATER/CEMENT CONTENT PER CUBIC MAXIMUM SHR IN STRAIN RATIO YARD ALL CONCRETE 3000 PSI 0.55 5 1/2 SACK N/A THE MINIMUM AMOUNT OF CEMENT LISTED ABOVE MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CONCRETE. THE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE AGGREGATE, WATER, AND ADMIXTURES AS WELL AS THE WATER -CEMENT RATIO, SLUMP, CONCRETE YIELD, AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH CHAPTER 26 OF ACI 318. ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BE AIR -ENTRAINED IN ACCORDANCE WITH ACI 318 TABLE 19.3.3.1 FOR MODERATE EXPOSURE CLASS F1. *PROVIDE f'c SPECIFIED IN TABLE FOR DURABILITY REQUIREMENTS. 2500 PSI CONCRETE MEETS STRENGTH REQUIREMENTS, THEREFORE SPECIAL INSPECTION IS NOT REQUIRED. MINIMUM LAPS AND EMBEDMENT UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE AS TABULATED BELOW: f'c = 3000 PSI DEVELOPMENT LENGTH LAP SPLICE BAR TENSION COMPRESSION TENSION COMPRESSION SIZE TOP BARS OTHER BARS ALL BARS TOP BARS OTHER BARS ALL BARS #3 22 17 9 28 22 12 #4 29 22 11 37 29 15 #5 36 28 14 47 36 19 #6 43 33 17 56 43 23 #7 63 48 20 81 63 27 #8 72 1 55 22 93 1 72 30 NOTE: 1. ALL LENGTHS ARE IN INCHES. 2. ALL LAP SPLICES ARE CLASS B. 3. "TOP BARS" ARE HORIZONTAL REINFORCEMENT PLACED SUCH THAT MORE THAN 12 INCHES OF CONCRETE IS CAST IN THE MEMBER BELOW THE BAR. CONCRETE COVER ON REINFORCING CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3" CONCRETE EXPOSED TO EARTH AND WEATHER: #6 BARS AND LARGER 2" #5 BARS AND SMALLER 1 1/2" CONCRETE NOT EXPOSED TO EARTH OR WEATHER: SLABS, WALLS AND JOISTS 3/4" COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1 1/2" CONCRETE GENERAL NOTES PROVIDE CORNER BARS TO MATCH THE HORIZONTAL REINFORCING WITH TENSION LAP SPLICE AT EACH SIDE PER TABLE, OR BEND ONE SIDE OVER TO PROVIDE TENSION LAP. PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLABS ON GRADE TO BREAK UP SLAB INTO RECTANGULAR AREAS OF NOT MORE THAN 400 SQUARE FEET EACH. AREAS TO BE AS SQUARE AS PRACTICAL AND HAVE NO ACUTE ANGLES. JOINT LOCATIONS TO BE APPROVED BY THE ARCHITECT. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND PROPERLY PREPARED IMMEDIATELY PRIOR TO POURING OF CONCRETE. DOWEL STEEL SHALL BE THE SAME SIZE AND SPACING AS MAIN REINFORCING DETAILED BEYOND JOINT. UNLESS INDICATED OTHERWISE, REINFORCE AROUND OPENINGS GREATER THAN 12" IN EITHER DIRECTION WITH (2) #5 EACH SIDE AND (1) #5 x 4'-0" DIAGONAL AT EACH CORNER. EXTEND BARS 2'-0" BEYOND EDGE OF OPENING. IF 2'-0" IS UNAVAILABLE, EXTEND AS FAR AS POSSIBLE AND HOOK. HOOK ALL REINFORCING INTERRUPTED BY OPENINGS. BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. PROVIDE 3/4" CHAMFER AT ALL CORNERS UNLESS NOTED OTHERWISE. STRUCTURAL STEEL STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE AISC "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS", LATEST EDITION. PLATES, ANGLES, CHANNELS, AND RODS SHALL CONFORM TO ASTM A36, Fy = 36 KSI. STRUCTURAL TUBING SHALL CONFORM TO ASTM A500 GRADE B, Fy = 46 KSI. STEEL PIPE SHALL CONFORM TO ASTM A53 GRADE B, Fy = 35 KSI. BOLTS CONNECTING STEEL MEMBERS SHALL CONFORM TO ASTM A325-N. BOLTS SHALL BE 3/4"0 MINIMUM, UNO ANCHOR BOLTS SHALL CONFORM TO ASTM A307. CONTRACTOR SHALL PROVIDE CONNECTION ADJUSTMENT TOLERANCES TO SATISFY THE REQUIREMENTS OF AISC MANUAL OF STEEL CONSTRUCTION. UNLESS SPECIFIED AS STAINLESS STEEL, ALL STEEL MEMBERS, SHAPES, BOLTS, AND ACCESSORIES EXPOSED TO WEATHER SHALL BE HOT DIP GALVANIZED. WELDING WELDING SHALL CONFORM TO AWS "STRUCTURAL WELDING CODE", LATEST EDITION. ALL WELDING SHALL BE DONE WITH 70 KSI LOW HYDROGEN ELECTRODES. WHERE NOT CALLED OUT, MINIMUM FILLET WELD SIZE SHALL BE PER TABLE 5.8 IN AWS D1.1, LATEST EDITION. WELDING OF REINFORCING BARS SHALL NOT BE PERMITTED UNLESS SPECIFICALLY CALLED OUT ON DRAWINGS OR APPROVED BY STRUCTURAL ENGINEER. WELDING OF GRADE 60 REINFORCING BARS SHALL BE PERFORMED USING LOW HYDROGEN ELECTRODES. WELDING OF GRADE 40 REINFORCING BARS SHALL BE PERFORMED USING E70XX ELECTRODES. SEE REINFORCING NOTES FOR MATERIAL REQUIREMENTS OF WELDED BARS. WELDING WITHIN 4" OF COLD BENDS IN REINFORCING BARS IS NOT PERMITTED. ALL WELDING SHALL BE DONE BY WASHINGTON ASSOCIATION OF BUILDING OFFICIALS (WABO) CERTIFIED WELDERS. EXISTING BUILDING CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE REDESIGN. CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. CONTRACTOR TO SEE ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS). TEMPORARY SHORING CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL INSTALL AND MAINTAIN TEMPORARY SHORING AND BRACING IN ADDITION TO SHORING SHOWN ON THESE PLANS AS NECESSARY TO PROTECT WORKERS, EXISTING BUILDINGS, STREETS, WALKWAYS, UTILITIES AND OTHER EXISTING AND PROPOSED IMPROVEMENTS AND EXCAVATIONS AGAINST LOSS OF GROUND OR CAVING EMBANKMENTS. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR REMOVAL OF ANY TEMPORARY SHORING AND BRACING, AS REQUIRED. LEGEND DEFINITION SYMBOL DEFINITION SYMBOL DIRECTION OF FRAMING NATIVE SOIL . III— —III—III— EXTENT OF FRAMING lift GRANULAR FILLNOMM COLUMNS STRUCTURAL STEEL COLUMN BEARING ON BEAM P RATED SHEATHING BEAM CONTINUOUS OVER SUPPORT � SHEAR WALL (SEE SCHEDULE) SWX CONCRETE WALL COLUMN MARK (SEE SCHEDULE) BEARING STUD WALL FOOTING MARK (SEE SCHEDULE) O NON -BEARING STUD WALL ( J HOLDOWN MARK (SEE SCHEDULE) BEARING STUD SHEAR WALL HANGER MARK (SEE SCHEDULE) O NON -BEARING STUD SHEAR WALL FLAG NOTE (SEE PLAN NOTES) CMU WALL�:XXXZZ3 STEEL MOMENT FRAME CONN. y /— �V ABBREVIATIONS (A) ABOVE GLB GLUE -LAMINATED BEAM AB ANCHOR BOLT HORIZ HORIZONTAL ALT ALTERNATE KIP KING POST ARCH ARCHITECT KSI KIPS PER SQUARE INCH (B) BELOW L ANGLE BD BAR DIAMETER MECH MECHANICAL BLKG BLOCKING MF MOMENT FRAME BM BEAM MTL METAL BOT BOTTOM INS NEAR SIDE BRNG BEARING OC ON CENTER BTWN BETWEEN OPP OPPOSITE CJP COMPLETE JOINT PENETRATION PL PLATE CLR CLEAR PLCS PLACES CMU CONCRETE MASONRY UNIT PSI POUNDS PER SQUARE INCH COL COLUMN PSF POUNDS PER SQUARE FOOT CONC CONCRETE CONNECTION P/T POST TENSIONED CONN PT PRESSURE TREATED CONT CONTINUOUS REINF REINFORCING COORD COORDINATE REQ'D REQUIRED DBL DOUBLE SCHED SCHEDULE SIMILAR DIET DETAIL SIM DIA DIAMETER SOG SLAB ON GRADE DIM DIMENSION STD STANDARD DIR DIRECTION STIFF STIFFENER EA EACH STL STEEL ELEV ELEVATION EACH SIDE SYMM SYMMETRICAL SHEARWALL ES SW EX EXISTING TOC TOP OF CONCRETE EXP EXPANSION TOS TOP OF STEEL FLR FLOOR FOUNDATION TOW TOP OF WALL FDN TYP TYPICAL FTG FOOTING FAR SIDE UNO UNLESS NOTED OTHERWISE FS VERT VERTICAL GC GENERAL CONTRACTOR WF WIDE FLANGE ELEV 0'-0".o MAIN FLOOR LEVEL SURVEY SCALE: 1/8" = V-0" UPPER FLOOR LEVEL SURVEY SCALE: 1/8" = V-0" 5'-0" 0 5'-0" 5'-0" 0 5'-0" ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 GU jL 4�' Cs of WAs� ti� o 25385 GISfER 1 s`SIONAL �Cs J Q Z O Co U � (n W Lu Q a 12/WZ DESIGN: BEL DRAWN: JCP CHECK: GAG JOB NO: 21363.10 DATE: 1 2/03/21 IVA Q W RECEIVED Dec 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W 0 U 0 Z N W pp 0 J 0) W Q a� o Z N W N Q Z m N O � � 0 m O) W SHEET: Simi C�� I 1'-0" 3., O O CHIP OUT EXIST FTG AS REQ'D TO ANCHOR PILE BRACKET TO EXIST FOUNDATION, TYP (11) PILES @ 3'-6" OC MAX 35'-0" INSTALL PILE PER DET 2/S2.1 & 3/S2.1,TYP 2'-6" 05 06 U 8 09 10 11 12 13 �4) - - - - - ---------------------------- - - - - - - - - ----- I I I I I I I I I I I I I I I I 1� I 0 INSTALL PILE PER DET u, 2/S2.1 & 3/S2.1, TYP j EXIST SLAB I ON GRADE I I I I � I I +1 I I I I I I I I I I I I I I I I I I I I I I I I I I L------------------------------------- L--------------------------� FOUNDATION PLAN SCALE: 1/4" = V-0" FOUNDATION PLAN NOTES: 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS & NOTIFY ALL PARTIES OF ANY DISCREPANCIES.. 2. REFER TO GEOTECHNICAL REPORT FOR PIN PILE EMBEDMENT & ADDITIONAL INSTALLATION REQUIREMENTS NOT REFERENCED HERE. 3. VERIFY LOCATION OF EXTERIOR UTILITIES PRIOR TO PILE DRIVING. 4. "S1" INDICATES 6" STRUCTURAL SLAB W/ #5 LONGITUDINAL BARS @ 6" OC & #4 TRANSVERSE TEMPERATURE BARS @ 16" OC. 4 (8) PILES @ 2'-6" OC MAX 17'-6" 15 16 17 18 19 )20) 21 22 I F ------------- - - - - - - - -- ---� I I I I I I 5 I y (6) PILES @ 4'-0" OC MAX I 2-_0�- 6 27 28 16'-8" 29 30 31 1 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — � • • • • • • 1 ----------------------------bill- ----------I I I I V) EXIST CRACK TO BE I PATCHED W/ SIKADUR 5 CRACK SEALANT, TYP I 52.1 (8) PILES @ 4'-0" OC MAX 1 I _ 17'-8" 1 -- 2- - 33---34---35 -- 36 -- 37----38--- 39 --I I I I I SIMPSON ABU POST BASE. I PROVIDE (2) PILES I SAW -CUT BENEATH COLUMN I I EXIST SLAB I I I 1 I I I I EXIST SLAB I ON GRADE I I I I I I I I I I I I I I I I I I I I I I ■ I I I I I I I I I I L--------------------------------------J 2'-0" 4 AT INTERFACE OF NEW & EXIST CONC, PROVIDE 44 x 3'-0" LONG DOWELS @ 18" OC. CENTER DOWELS WITHIN EXIST SLAB & EMBED 4" USING SIMPSON SET XP EPDXY 2'-0" 0 2'-0" 4'-0" EXIST WALL FRAMING II EXIST GRADE ry� EXIST FOUNDATION CHIP OUT PORTION OF FTG TO INSTALL ANGLE DIRECTLY BENEATH STEM WALL 1/2" 0 THREADED ROD W/ 4" MIN EMBED INTO FTG W/ HILTI HIT HY 200 INJECTION ADHESIVE. ALTERNATELY 1/2"0 EXPANSION ANCHORS MAY BE USED W/ 4" MIN EMBED - i� L6 x 6 x 3/4 x 12" LONG II I I I I I I I I I I I I I I I I I I I I I I I I 7/8"o THREADED ROD 3 1" EXTRA STRENGTH \PIPE x 4" LONG TS5 x 3 x 1/4 x 8" LONG PIPE PILE PER PLAN CONSTRUCTION SEQUENCE NOTES: 1. INSTALL PIPE PILE. 2. TIGHTEN NUTS AFTER ANGLE SEATS TO FOUNDATION. TYPICAL STABILIZATION DETAIL SCALE: 1 1/2" = V-0" SLAB REINFORCING PER FOUNDATION PLAN NOTES, CENTERED IN SLAB STRUCTURAL SLAB PER PLAN NOTES & STRUCTURAL NOTES e z wQ a� (-A _ O O Do, o v0 Op .Cp o� 50, Op o NOTE: TOP PL & THREADED ROD NOT SHOWN FOR CLARITY EX FOUNDATION 5/8"0 LONG SLOTTED HOLES 1" ES PIPE x 4" LONG, TYP TS5 x 3 x 1/4 x 8" LONG I I I 41 I _ I I Ln I �.o I I I PIPE PILE PER PLAN 1/4 1/4 L6 x 6 x 3/4 x 12" LONG TYPICAL DETAIL 3 SCALE: 1 1/2" LAPPED PER STRUCTURAL NOTES Lij U i""' #4 x 3'-0" LONG DOWEL BAR, • SPACED TO MATCH SLAB REINF, EMBEDDED 4" W/ SIMPSON SET-XP EPDXY & LAPPED W/ SLAB REINF U m FILL VOIDS BENEATH FTG 1 W/ GEOFOAM AS REQ'D (2) #3 CLOSED STIRRUP 1 AT EA PILE, 6" FROM PILE PIPE PILE I j ADD SPACER AS 6�� NECESSARY TO PER PLAN I I 8" (3) #4 9" I CONCEAL PILE BELOW SLAB 1'-0' TYP SECTION SCALE: 1" = V-0" SECTION SCALE: 1" = V-0" THICKENED EDGE SLAB GRADE BEAM WITH (2) #5 CONT BARS, TOP & BOTTOM r REINF PER PLAN mj 2" 0 PIPE PILE, TYP �z Lu Q a� REINF PER NOTE ABOVE r4 TYP ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 Cs GUI W'4 o 25385 ��GIS'fER� 1 s`SIONAL �Cs 12/WZ w � Q O C N Y tr Q DESIGN: BEL DRAWN: JCP CHECK: GAG JOB NO: 21363.10 DATE: 1 2/03/21 ) Q J W Q ZRECEIVED 0 Dec 29 2021 QDEVELOPMENT CITY OF EDMONDS SERVICES Q QDEPARTMENT Z Z D Q O 7 W 0 Q U N J Z V) O W pp 0 J Z a- w Q O w Z w � V) ft Q Y N 0 Z Z m cv O o O W m Cy) w LL SHEET: S2ml