APPROVED BLD-Stair DetailREVISIONS I BY
0
A
Q w
7 �- X
T
RAT u q-\-a ��► 05
Q �a�
10
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
LANS MUST BE
ON JOB SITE
CITY OF EDMONDS
BUILDING DIVISION
APPROVED PLAN
City Of -Edmonds
Building Department
---------------------------------------------------
Work STAIR REMODEL
-----------------------------
- -------------------
Address 907 DAYTON ST
Owner PALACIOS
`-------------------------
Approved Date 03/28/2022/�� A6V
Building Official All( 6G(%�iit' /Qi
---------------------------- -----
---------------------------- ----------
Permit Number BLD2022-0320
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
(STAIR LIGHTING ALL STAIRWAYS SHALL'
■ BE PROVIDED WITH LIGHT SOURCES.
!WHERE INTERIOR STAIRWAYS HAVE 6 ■
.OR MORE RISERS A WALL SWITCH !
!SHALL BE PROVIDED AT EACH FLOOR.
■ I RC R303.7 & R303.8
HANDRAILS ARE REQUIRED AT STAIRS WITH FOUR
.OR MORE RISERS. ALL HANDRAILS TO BE LOCATED ■
134" TO 38" ABOVE TREAD NOSING. OPEN SIDES OF !
-STAIRS MORE THEN 30" ABOVE ADJACENT FLOOR ■
!SHALL HAVE HANDRAILS & GUARDRAILS. THE ! Zy-t2 �?\CV:0v�L
■HANDGRIP PORTION SHALL HAVE A CROSS
!SECTIONAL DIMENSION OF 1114" TO 2". IRC R311.7.8. `
' STRINGERS MUST HAVE A ■
. POSITIVE CONNECTION AT
' THE TOP AND BOTTOM OF ALL !
■ STINGERS FOR BOTH FLIGHTS'
OS STAIRS. ■
s
(3) 2x,j>zt%&e,
SUM �600
44 cne
....I . i ■ ....I . i ■ . i ■ i ■
! Enclosed Accessible Spaces under I
,stairs shall be protected with minimum
1 1/2 inch gypsum board per IRC R302.7
W
S Gowa
(HALF WALL SHALL BE DESIGNED TO RESIST A !
■CONCENTRATED LOAD OF 200 POUNDS IN ANY
I DIRECTION AT THE TOP OF THE WALLK. INFILL ■
.COMPONENTS SHALL BE DESIGNED TO RESIST i
IA HORIZONTAL LOAD OF 50 POUNDS OVER A !
!ONE SQUARE FOOT AREA. IRC R301.5. ■
p
14
q2 q A
b
4 i 14,k. L Dow t3-Vj
RECEIVED
Mar 16 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
JA
3
�
2
'
J
�r
Date?_ -,22-2.Z
Scale AS dJtT(\m
Drawn�,tn-1 t3
Job
Sheet
Of l Sheets
is x w nWam oN ea. mm ou"MrR.