Loading...
FIR2022-0035+Fire_Sprinkler_Equipment_Specification_Sheets+4.1.2022_10.27.00_AM+2775847Bulletin 157 Rev. K Ill Features 1. The Model F30R sprinkler utilizes Belleville Spring Closure Technology. Reliable is the first in the industry to produce a Quick Response Dry Concealed sprin- kler utilizing this technology. 2. Styles available • Pendent • Recessed FP Pendent • Recessed F1 Pendent • Concealed • Horizontal Sidewall • Recessed FP Horizontal Sidewall • Recessed F1 Horizontal Sidewall 3. 11/2" (38mm) escutcheon adjustment on pendent sprinkler. 4. 1/2" (13mm) escutcheon adjustment on recessed sprin- kler with push -on/ thread -off FP Model Escutcheon ring. 5. 3/8" (9.5mm) cover plate adjustment on concealed sprinkler with push -on/ thread -off CCP Cover Plate. 6. 3/4" (19mm) escutcheon adjustment on recessed sprinkler with F1 Escutcheon. 7. Attractive appearance. Employs 3mm frangible glass bulb and galvanized nipple. 8. Lengths available to accommodate installation di- mensions from 2" - to - 48" (51 mm - to - 1219mm), in '/4" (6mm) increments. See specific styles for correct "A" dimension range. 9. Available in a variety of plated and painted finishes. 10. Polyester Coated or Electroless Nickel PTFE (Teflon°)* Plated Corrosion Resistant Sprinklers. *Concealed Sprinkler is not corrosion resistance. US Patent Numbers 5,775,431 and 5,967,240. Other US Patents pending. Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Style Response Sprinkler System TvDe Hazard Pendent Recessed FP Pendent Wet Pipe Light Recessed F1 Pendent Quick Dry Pipe Ordinary CCP Concealed All Preaction R5714 Horizontal Sidewall Wet Pipe Recessed Horizontal Sidewall Quick Dry Pipe Light F1 & FP R5734 All Preaction 2. Certified by FM Approvals Style ty Response p Sprinkler System Type Hazard Pendent Wet Pipe Light Ordinary, Recessed F1 Pendent Quick Dry Pipe Groups (R5714) All Preaction 1&2 Horizontal Sidewall Wet Pipe Recessed F1 Horizontal Sidewall Quick Dry Pipe Light R5734 All Preaction 3. NYC MEA 258-93-E "DuPont Registered Trademark Model F3QR Quick Response Dry Sprinklers A�14 1-0 Pendent (See Fig. 1) Recessed FP Pendent (See Fig. 3) Recessed F1 Pendent (See Fig. 5) Recessed FP Horizontal Sidewall (See Fig. 8) Pendent / HB (See Fig. 2) Concealed (See Fig. 4) Horizontal Sidewall (See Fig. 6) I^ Horizontal Sidewall / HB (See Fig. 7) Recessed F1 Horizontal Sidewall (See Fig. 9) Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F3QR Dry Pendent Sprinkler "A" Dim. 2" to 48" (51mm to 1219mm) in 1/4" (6mm) increments Finishes(') Sprinkler Escutcheon Electroless Nickel PTFE(Teflon0)"I4> Electroless Nickel PTFE (Teflon®)" Bronze Brass (3) Chrome Chrome White Polyester (2) White (') Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) Not available for HB escutcheons. (4) cULus listed Corrosion Resistant s � 17-11 -J System Tee 1" NPT 2 1 /8" Dia. [54.Omm] "A" Dimension Hole in Ceiling Adjustment Range —1/4" [-6.4mm] 1 43/64" Dia. +1 1/4" [+31 .8mm] [42.5mm] 1 1 /2" [38.1 mm] Total Adjustment Sprinkler Can Ceiling 1 1/4" [31.8mm] 1/4" [6.4mm] Escutcheon eiling C Escutcheon eilina Adjustment Nominal Position of Escutcheon 1/4" [6.4mm] Protrusion 1 5/8" [41 .3mm] 3" Dia. [76.2mm] 157FG01 Fig. 1 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal position. Escutcheon adjustment provides '/4" (-6mm) to +11/4" (+32mm) "A" dimension adjustment range. Sprinkler Guard: Model C-2 Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 "DuPont Registered Trademark 9 Model F3QR Dry Pendent w/HB Escutcheon "A" Dim. 31/2" to 48" 89mm to 1219mm in'/4" 6mm increments Standard Temperature Ratings Classification Sprinkler Temperature Rating Max. Ambient Temp. Bulb Color Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate (1) 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green High 286-F(141°C) 225°F(107°C) Blue Listed and Certified only by cULus. Electroless Nickel PTFE (Teflon®)" Plated sprinklers, escutcheons and cups are recommended for exterior applications. L J System Tee 2 1/2" [63.5mm] 1 " NPT "A" Dimension Adjustment Range Dia. Hole in Ceiling 3 1/2" [88.9mm] —1/2" [-12.7mm] +1/2" [+12.7mm] Escutheon Dia. 1/2" [12.7mm] Escutheon Adj. Ceiling 1 " [25.4] Escutcheon Total Adj. 1/2" [12.7mm] Escutheon Adj. Nominal Position Sprinkler Can -----,.-of Escutcheon 1 —1 /4" [31 .75mm] 1 5/8" Nominal Protrusion [41 .3mm] 2 13/64" [55.88mm] 757FG02 �-. .-t Dia. Fig. 2 Note: The sprinkler can protrudes 11/4" when escutcheon is in nominal position. Escutcheon adjustment provides 112" (-12.7mm) to +1/2" (+12.7mm) "A" dimension adjustment range. Sprinkler Guard: Model C-2 Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 "DuPont Registered Trademark 3. Model F3QR Dry Recessed FP Pendent Sprinkler "A" Dim. 1 31/2" to 48" 89mm to 1219mm in'/4" 6mm increments Finishes"' Standard Temperature Ratings Sprinkler Escutcheon Electroless Nickel PTFE(Teflon°)•(3) Electroless Nickel PTFE (Teflon°)"(4) Bronze Brass Chrome Chrome White Polyester (2) White Uther tinishes and colors are available on special order. Consult factory for details. Cup remainds unfinished. Only the escutcheon will contain desired finish. 21 cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) cULus Listed Corrosion Resistant Sprinkler. (4) Cup and Escutcheon Electroless Nickel PTFE (Teflon®)" Plated. Sprinkler Max. Classification Temperature Ambient Bulb Color Ratin Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate (') 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green High (1) 286°F 141°C 225°F 107°C Blue Sprinkler cup and FP Escutcheon fabricated of steel and recommended for interior applications. O) Listed and Certified only by cULus. 2 1 /2" Dia. [63.50mm] "ADimension Hole in Ceiling " Adjustment Range +1 /4" 2 19/64" Dia. [±6.35mm] [58.34mm] Nominal Position F—of Escutcheon Ceiling 1 /4" [6.35mm] Escutcheon Adjustment 1/4" [6.35mm] Escutcheon Adjustment 1/2" [12.7m1, Total Adjustment s � T" —F-- ,1�11----,i II I I — r_ System Tee 3 7/32" Dia. [81 .76mm] 1 " N PT Sprinkler Cup Assembly Escutcheon �T Ceiling � 157FGOJ Fig. 3 Note: Do not install the Model F3QR Dry Recessed FP Pendent Sprinkler in ceilings which have positive pressure in space above. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 "DuPont Registered Trademark n Model F3QR Dry Pendent Concealed Sprinkler "A" Dim. 31/z" to 48" (89mm to 1219mm) in'/4" (6mm) increments (_(`P Cnvor Plata (') Pinichas'21 Standard Temperature Ratings Standard Finishes Special Application Finishes Chrome Plated Bright Brass Plated White Black Plated Black Paint Off White Satin Chrome Utilizes the 1/2" cover plate with 3/8" total adjustment. 2> Other finishes and colors are available on special order. Consult factory for details. Sprinkler Cover Plate Max. Classification Temperature Temp. Rating Ambient Rating Temp. Ordinary 135°F (57°C) 135°F (57°C) 100°F (38°C) Ordinary 155°F (68°C) 135°F (57°C) 100°F (38°C) Intermediate (') 175°F (79°C) 165°F (74°C) 150°F (66°C) Intermediate 200°F (93°C) 165°F (74°C) 150°F (66°C) High (') 286°F (141°C) 165°F (74°C) I 150°F (66°C) Sprinkler cur) fabricated of steel and CCP Cover Plate fabricated of brass and recommended for interior applications. (') Listed and Certified only by cULus. r - - - - - - -----Jr ------1 ---------- r-AF---li P I ? � System Tee 1" NPT 2 1/2" Dia. - [6.35mm] "A" Dimension Hole in Ceiling Adjustment Range ± 3/16" 2 19/64" Dia. [±4.76mm] [58.34mm] Nominal Position of Coverplate Sprinkler Cup Assembly Coverplate Ceiling Assembly Ceiling 3/16" [4.76mm] Coverplate Adjustment 3/16" [4.76mm] Coverplate Adjustment 3 184. 16" Dia. 13mm] 3/8" [9.53mm] Total Adjustment 157FG04 Fig. 4 Note: Do not install the Model F3QR Dry Concealed Pendent Sprinkler in ceilings which have positive pressure in the space above. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 "DuPont Registered Trademark 5. Model F3QR Dry Recessed F1 Pendent Sprinkler "A" Dim. 31b" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Finishes Sprinkler Escutcheon Collar Electroless Nickel PTFE(Teflon®)*(3) Electroless Nickel PTFE (Teflon®)* Electroless Nickel PTFE (Teflon®)' Chrome Chrome Chrome White Polyester (2) White White (1) Other finishes and colors are available on special order. Consult factory for details. (1) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) cULus Listed Corrosion Resistant Sprinkler. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate (1) 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green High (1) 286°F (141°C) 225°F (107°C) Blue (1) Listed and Certified only by cULus. "A" Dimension Adjustment Range ± 1 /4" [±6.35mm] 2 1 /2" Dia. [63.50mm] Hole in Ceiling Nominal Position of Escutcheon Ceiling s� ----r--'I�---71 II II I III IiI �I� jIIII III � 1 J � System Tee 1 /4" [6.35] Escutcheon Adjustment 1 /4" [6.35] Escutcheon Adjustment 1/2" [12.7mm] Adjustment 2 27/32" [72.2mm] Fig. 5 Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 *DuPont Registered Trademark 1" NPT 1 15/16" [49.2mm] 15/16" [23.8mm Sprinkler Cup Assembly 1 /8" Ceiling �[3.2mm] Escutcheon 157FG05 Model F3QR Dry Horizontal Sidewall Sprinkler "A" Dim. 2" to 48" 51mm to 1219mm in'/4" 6mm increments Pinichoc(') Sprinkler Escutcheon Electroless Nickel PTFE(Teflon®)*(4) Electroless Nickel PTFE (Teflon®)' Bronze Brass (3) Chrome Chrome White Polyester (2) White Other finishes and colors are available on special order. Consult factory for details. z cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) Not available for HB escutcheons. (4) cl-Lus listed Corrosion Resistant System Tee 151FG06 1 1 /2" [38.1Omm Total Adjustment 1 1 /4" [31 .75mm] Escutcheon Adjustment 1 " NPT 2 1 /8" Dia [53.98mm] Hole in Wall Sprinkler Can "A" Dimension Adjustment Range 1 /4" [6.35mm] + 1 1 /4 [+31 .75mm] 12 T i] Min. L-5U4.bUmm] Max. 1 /4" [6.35mm] Escutcheon Adjustment 2 3/32" [53.18mm] 3" [76.2Omm] 1 /4" [6.35mm] Protrusion Nominal Position of Escutcheon Fig. 6 Note: The sprinkler can protrudes'/4" when escutcheon is in nominal position. Escutcheon adjustment provides '/4" (-6mm) to +1'/4" (+32mm) "A" dimension adjustment range. Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 "DuPont Registered Trademark 7. Model F3QR Dry HSW w/HB Escutcheon "A" Dim. 1 31/2" to 48" (89mm to 1219mm) in'/4" (6mm) increments Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate '> 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green Hiah (1) 286°F (141°C) 225°F (107C) Blue (1) Listed and Certified only by cULus. 1 " [25.4mm] Total Adjustment 1/2" [12.7mm] Escutcheon Adjustment 1/2" [12.7mm] Escutcheon Adjustment System Tee r-- 1" NPT 2 1/2" Dia. [63.5mm] Hole in Wall �~ "A" Dimension --- Adjustment 157FG07 Range + 1/2" [+12.7mm] — 1/2" [12.7mm] Ceiling 1 T 4" [101.60mm] Min. 12" [304.80mm] Max. 2 3/32" [53.18mm] 213/64" 3-1/2" [55.88mm] Dia. [88.9mm] Escutcheon Dia. 1-1/4" [31.75mm] Nominal Protrusion Sprinkler Can Escutcheon Nominal Position Of Escutcheon Fig. 7 Note: The sprinkler can protrudes 11/4" when escutcheon is in nominal position. Escutcheon adjustment provides '/z" (-12.7mm) to +1/2" (+12.7mm) "A" dimension adjustment range. Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 "DuPont Registered Trademark E11 Sprinkler Escutcheon Electroless Nickel PTFE(Teflon°)*(3) Electroless Nickel PTFE (Teflon°)`(') Bronze Brass Chrome Chrome White Polyester (2) White (') Other finishes and colors are available on special order. Consult factory for details. Cup remainds unfinished. "See page 2" (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) cULus Listed Corrosion Resistant Sprinkler. (4) Sprinkler's can and FP Escutcheon Electroless Nickel PTFE (Teflon®)' Plated recommended for exterior applications. System Tee 1 " N PT Model F3QR Dry Recessed FP Horizontal Sidewall Sprinkler "A" Dim. 31/z" to 48" (89mm to 1219mm) in (6mm) increments Finishes "' Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate'> 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green High '> 286°F 141°C 225°F 107°C Blue (') Listed and Certified only by cULus. I Ceiling 1 13/32" Escutcheon [35.7mm] 4" [101.6mm]Min. Cup 12" [304.8mm]Max. 2 1 /2" Dia. [63.5mm] Hole in Wall 2 19/64" Dia. [58.3mm] "A" Dimension Adjustment Range 157FG08 ± 1 /4" [±6.35mm] 3 7/32" Dia. [81 .8mm] o Nominal Position � Z of Escutcheon FOR FACTORY MUTUAL (FM) • 4" — 6" FOR UNDERWRITERS LABORATORIES (UL) Fig. 8 1 /4" [6.35] Escutcheon Adjustment 1/2" [12.7mm] Escutcheon Adjustment 1 /4" [6.35] Escutcheon Adjustment Notes: Do not install the Model i Dry Recessed FP Horizontal Sidewall Sprinkler in walls which have positive pressure in their side space. • Listed by cULus for Quick Response. Approved by FM for Standard Response. • Recessed Horizontal sidewall sprinklers are listed with cl-li for installation of min. 4" (100mm) - to - max. 6" (150mm) below ceiling and ap- proved by FM for installation of min. 4" (100mm) - to - max. 12" (300mm) below ceiling. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 `DuPont Registered Trademark s Model F3QR Dry Recessed F1 Horizontal Sidewall Sprinkler "A" Dim. 31/2' to 48" (89mm to 1219mm) in'/4" (6mm) increments Finichnc ' Standard Temperature Ratings Sprinkler Escutcheon Collar Electroless Nickel PTFE(Teflon6)`(3) Electroless Nickel PTFE (Teflon")` Electroless Nickel PTFE (Teflon°)' Chrome Chrome Chrome White Polyester (2) White White (') Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (1) cULus Listed Corrosion Resistant Sprinkler. System Tee N I Escutcheon Sprinkler Cup Assembly 1 " N PT 2 1 /2" Dic. [63.5mm] Hole in Wall 1 1 5/ 1 6" [49.2mm] "A" Dimension 157FG09 Adjustment Range ± 1 /4" [±6.35mm] Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate (') 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green High (') 286°F (141°C) 225°F (107°C) Blue (') Listed and Certified only by cULus. F Ceiling I [3.2mm] [—� 4" [101.6mm]Min. 12" [304.8mm]Max. 2 27/32" [72.2mm] Nominal Position [--A of Escutcheon 1 /4" [6.35] Escutcheon Adjustment 1 /2" [1 2.7mm] Adjustment 1 /4" [6.35] Escutcheon Adjustment FOR FACTORY MUTUAL (FM) • 4" 6" FOR UNDERWRITERS LABORATORIES (UL) Fig. 9 • Listed by cULus & Approved by FM for Quick Response. • Recessed Horizontal sidewall sprinklers are listed with cULus for installation of min. 4" (1001 - to - max. 6" (150mm) below ceiling and approved by FM for installation of min. 4" (100mm) - to - max. 12" (3001 below ceil- ing. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 "DuPont Registered Trademark 10. Technical Data: Orifice Size:'/2" (15mm) Thread Size: 1" NPT per ANSI B2.1 Working Pressure: 175 psi (12 bar) Nominal K Factor - US / (Metric): 5.6 / (80) Product Description Reliable Model F3QR Dry Sprinklers are quick response sprinklers utilizing a durable 3mm frangible glass bulb. This quick response enables these sprinklers to apply water to a fire much sooner than standard response sprinklers of the similar temperature rating. Model F3QR Dry Sprinklers are intended for use in dry and preaction systems and in areas subjected to freezing tem- peratures, such as freezers and unheated portions inside and outside buildings. Environments wherein dry sprinklers are employed can be corrosive. For this reason, Model F3 Sprinklers have a special wax fillet placed in the gap between the cup that supports the bulb and the wrenching boss. This wax will not interfere with the operation of the sprinkler, and it prevents contaminents from entering the internal portion of the drop nipple. The wax must not be removed. Operation The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. When the tem- perature increases sufficiently, due to afire, the bulb shatters allowing operating parts to clear the waterway. This enables the inlet seal to release air or water and subsequently, cause water flow over the deflector in a uniform spray pattern, con- trolling or extinguishing the fire. Ordering Information Specify: 1. Sprinkler Type (select one): (a) Model F3QR Dry Pendent (b) Model F30R Dry Pendent/HB (c) Model F3QR Dry Recessed FP Pendent (d) Model F30R Dry Recessed F1 Pendent (e) Model F3QR Dry Concealed Pendent (f) Model F3QR Dry Horizontal Sidewall (g) Model F30R Dry Horizontal Sidewall/HB (h) Model F3QR Dry Recessed FP Horizontal Sidewall - UL (i) Model F30R Dry Recessed F1 Horizontal Sidewall - UL & FM 2. Sprinkler Temperature Rating. 3. Sprinkler Finish. 4. Escutcheon type (F1 or FP). 5. Cover Plate/Escutcheon Finish. 6. Length: "A" Dimension (face of tee to face of ceiling or wall) in (6mm) increments. 7. Model F3QR Dry Pendent (a) is available without sprinkler can and escutcheon. Note: 1. The "A" dimension is based on a nominally gauged pipe thread "make-up" of 0.600" (15mm) per ANSI B2.1 [71/2 threads approximately]. 2. All platings and paintings are decorative and intend- ed for interior use. General Installation Instructions Model F30R dry sprinklers must be installed only in stan- dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) pipe tees in the horizontal position, even at branch line ends. They should not be installed into elbows or pipe couplings located on drop nipples to the sprinklers. For these and other fittings including CPVC, the dry sprinkler should be installed into a fitting to allow protrusion into the fitting in accordance with the diagrams. The "A" dimension of the dry sprinkler, which extends into the freezers or a freezing zone from wet pipe systems, should be selected to provide, as a minimum, the specified lengths in inches shown in Fig. 10. Caution: Do not install Model F30R Dry sprinklers into CPVC adapt- er fittings or tees that have an internal obstruction. This will damage the sprinkler and /or the fitting. Refer to Fig. 11. During installation, the following steps must be followed: 1. Cut the specified size hole (see illustrations) for the sprin- kler in the ceiling or wall directly in line with the tee. 2. Apply pipe joint compound to the 1" (25mm) pipe threads and install sprinkler using the Model F3 or XL02 Sprinkler Wrench as specified'. 3. Install the Model FP push -on / thread -off escutcheon or CCP cover plate if required. Note: Installation of the Model F30R Sprinklers is not recom- mended in copper pipe systems, as this may reduce the life expectancy of the sprinklers. Model F30R Concealed and Recessed In- stallation Instructions • The Model XL02 wrench (Fig. 12) is designed to lo- cate on the wrenching pads of the recessed sprin- kler while centering in the cup'. A standard'/2" drive ratchet may be used to drive this wrench. Fig. 13 and Fig. 14 show sequentially the insertion of the wrench. First the wrench, with its jaws above the sprinkler de- flector, is moved laterally until centered with the cup. Then raise the wrench inside of the cup until its jaws engage the sprinkler's square wrenching pads (Fig. 14). To remove the wrench, follow this procedure in reverse order. Care should be taken to avoid striking the deflector, with the wrench. • Model F3 Wrench (Fig. 15) is used for installation of Pendent and Horizontal Sidewall sprinklers'. Installation Wrenches: Throughout this technical bulletin, Reliable has specified specific installation wrenches for use on each version of our sprinklers. A pipe wrench may also be used to install a dry sprinkler provided that it only interfaces with the steel outer tube of the assembly (Item #8 on fig 16). Keep in mind that a pipe wrench will incorporate a large amount of torque into the final assembly. This torque will have to be matched or exceeded upon the sprinkler's removal at a later date. 11. RECOMMENDED EXPOSED MINIMUM BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DRY PENDENT SPRINKLER SHOWN) INSTALL 1 INCH NPT THREADED END OF DRY PENDENT SPRINKLER WET PIPE INTO THE 1 INCH NPT SIDE OUTLET AMBIENT TEMPERATURE OF PROTECTED AREA* AT THE DISCHARGE END OF THE SPRINKLER EXPOSED BARREL AMBIENT TEMPERATURE 40'F/4'C I 50'F/10'C I 60'F/16C EXPOSED MINIMUM BARREL LENGTH** (FACE OF TEE TO TOP OF CEILING) IN. (MM) IN. (MM) IN. (MM) 40-F (4'C) 0 0 0 30'F (—VC) 0 0 0 29F (-7'C) 4 (101) 0 0 10-F (-12'C) 8 (203) 1 (25.1) 0 0'F (-18'C) 12 (305) 3 (75) 0 —10'F (-23'C) 14 (356) 4 (101) 1 (25.1) —20-F (-29'C) 14 (356) 6 (152) 3 (75) —30-F (-34'C) 16 (406) 8 (203) 4 (101) —40'F (-40'C) 18 (457) 8 (203) 4 (101) —50-F (-46'C) 20 (508) 10 (254) 6 (152) —60'F (-51'C) 20 (508) 10 (254) 6 (152) OF A MALLEABLE IRON TEE FITTING PER ANSI B 16.3 (CLASS 150) OR CAST IRON THREADED TEE FITTING PER ANSI 16.4 (CLASS 125) ONLY. yr_�II11II�DJII_�_�_�_IIII1I�_� Ls—i i zL IF HUMIDITY AND TEMPERATURE DIFFERENTIAL CAUSES CONDENSATION ON THE EXPOSED DRY SPRINKLER, CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION, FOAM INSULATING TAPE OR EQUIVALENT. MINIMUM (HEATED AREA) SEAL THE CLEARANCE SPACE EXPOSED AROUND THE SPRINKLER TO AVOID BARREL LEAKAGE OF AIR INTO THE PROTECTED LENGTH AREA AND CONSEQUENT FORMATION OF CONDENSATE AROUND THE FRAME, WHICH COULD INHIBIT OPERATION OR CAUSE PREMATURE OPERATION. SEE BELOW FOR RECOMMENDED METHODS 'A` CLEARANCE 17 DIMENSION HOLE * THE PROTECTED AREA REFERS TO THE AREA BELOW THE CEILING. THE AMBIENT TEMPERATURE IS THE TEMPERATURE AT THE DISCHARGE END OF THE SPRINKLER. FOR PROTECTED AREA TEMPERATURES THAT OCCUR BETWEEN THE VALUES LISTED, USE THE NEXT COOLER TEMPERATURE. **THE MIN. REQUIRED BARREL LENGTH IS NOT THE SAME AS THE 'A' DIMENSION. ESCUTCHEON CEILING NOTE: EXPOSED MINIMUM BARREL LENGTHS ARE INCLUSIVE UP TO 30MPH WIND VELOCITIES IN THE PROTECTED AREA. (PROTECTED AREA) —3" DIA. *RECOMMENDED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO HORIZONTAL SIDEWALL DRY SPRINKLERS* RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PIPE (STANDARD DRY PENDENT SPRINKLER SHOWN) WET PIPE �IHIHI � i i u n (HEATED AREA) (HEATED AREA) MINIMUM MINIMUM EXPOSED EXPOSED BARREL BARREL LENGTH (SEE ABOVE) DECKTITE FLASHING RASCO #4003910 INSIDE FACE SEAL LENGTH (SEE ABOVE) (RECOMMENDED) � CLEARANCE HOLE i INSULATED FREEZER, OR COOLER STRUCTURE OR EXTERIOR FRAMING (PROTECTED AREA) DRY SPRINKLER (PROTECTED AREA) DRY SPRINKLER IN COLD AREA IN COLD AREA 157FG10 Fig. 10 12. *CAUTION* DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLERS INTO CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL DAMAGE THE SPRINKLER AND/OR THE FITTING. CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. INTERNAL NO OBSTRUCTION INTERNAL OBSTRUCTION FEMALE FEMALE PIPE PIPE . THREAD THREAD INCORRECT CORRECT CPVC ADAPTER CPVC ADAPTER FITTING OR TEE FITTING OR TEE 1 SHORTER LONGER INLET INLET MALE MALE PIPE PIPE THREAD THREAD MODEL F3-PL, MODEL F3QR-PL OR STANDARD MODEL DH56 HSW-PL MODEL F3. DRY SPRINKLER MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION 016fgO8A Fig. 11 13. Fig. 12 - XL02 Wrench Fig. 13 - XL02 Wrench Fig. 15 - F3 Wrench Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- VICE FOR FIRE PROTECTION. Removal of the pro- tectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PRO- TECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Fig. 14 - XL02 Wrench Maintenance The Model F3QR Quick Response Dry Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not remove the factory applied thermally sensitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gently vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non - operation. 14. MATERIAL SPECIFICATIONS ITEM # DESCRIPTION MATERIAL SPECIFICATION 1 FRAME BRASS PER UNS C83600 2 DEFLECTOR BRONZE PER UNS C51000 3 LOAD SCREW BRASS PER UNS C22000 4 SEAT ADAPTOR BRASS ALLOY PER UNS C36000 5 BULB INSERT COPPER ALLOY PER UNS C331400 6 GLASS BULB GLASS W/GLYCERIN SOLUTION 7 ORIFICE ADAPTOR BRASS ALLOY PER UNS C36000 8 OUTER TUBE GALVANIZED STEEL 9 INNER TUBE BRASS ALLOY PER UNS C23000 10 YOKE BRASS ALLOY PER UNS C38000 11 INLET BRASS ALLOY PER UNS C35330 12 CAP BRASS ALLOY PER UNS C54400 13 SPRING WASHER/SEAL TEFLON COATED BERYLLIUM NICKEL 14 FLIP DISK BRASS ALLOY PER UNS C54400 15 CAN/ESCUTCHEON PAINTED OR PLATED MILD STEEL (PIPE WRENCH MAY ONLY BE USED ON OUTER STEEL PIPE OF SPRINKLER) 016fg10 153fg 16 57fg 16 °EARANCE OF DEFLECTOR MAY VARY DEPENDING ON MODEL Fig. 16 15. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured b Reliable Automatic Sprinkler Co., Inc. Recycled ® (800) 431-1588 Sales Offices Paper RelsiablL (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 02/15 P/N 9999970175