Loading...
FIR2022-0035+Fire_Sprinkler_Plan+4.1.2022_10.27.06_AM+2775848STEELJOIST/BEAM IE G MCLAMP W/ TRAINING STRAP ATR HANGER HANGER LABEL -12S CONCRETE DECK 4 G �8"HDIPTZ g ATR RING HANGER FOR PIPE SIZE 1"- 2" tA —�_ I I WALK-IN I COOLER WALK-IN I i ♦A COOLER I I q SCOPE OF WORK: 1. COLUMBIA FIRE INC. SCOPE OF WORK IS TO ADD AND RELOCATE FOR THE NEW TI TO COMPLY WITH NFPA #13-2016. 2. SPRINKLER PLAN SUBMIT TO THE CITY OF EDMONDS FOR APPROVAL. 3. MATERIALS PER NFPA #13-2016 EDITION STANDARDS. 4. TESTING PER NFPA #13-2016 EDITION AND THE CITY OF EDMONDS. GENERAL NOTES: 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL LISTED OR FM APPROVED. 2. PIPE LENGTH ARE SHOWN AS CUT LENGTH. 3. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13-2016 EDITION. 4. PIPING SHALL BE IN ACCORDANCE WITH NFPA #13-2016 EDITION. 5. JOINING OF PIPE/FITTINGS (THREADED AND WELDED) SHALL BE IN ACCORDANCE WITH NFPA #13-2016 EDITION. 6. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 7. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL. 8. ALL FIRE ALARMS, WIRING, AND MONITORING ARE TO BE INSTALLED BY OTHERS. RESPONSIBILITY OF THE SUB -CONTRACTOR CONSTRUCTION TYPE: KITCHEN 1. CONCRETE 2. UNOBSTRUCTED PLUG EXI; PENDENT 1 08 v N I WALK-IN I RESTROOM COOLER I KITCHEN 1 I q 0-8 I I I M I LEVEL1 - FIRE PROTECTION SCALE: 1/8" = 1'-0" DRAWING ABBREVIATION DRAWING SYMBOLS FABRICATION SYMBOLS SPRINKLER LEGEND NORTH SPR - SPRIG RN - RISER NIPPLE DP - DROP FF - FINISH FLOOR TS - TOP OF STEEL OTS - OPEN TO STRUCTURE COJ - CUT ON JOB -� EQ BRACING f -HANGER Co + BRANCH LINE RESTRAINT CENTER LINE O HYDRAULIC CAL NODE CM1.A - SPRINKLER MAIN FAB NUMBER SPRINKLER LINE FAB NUMBER SPRINKLER TYPE / SIN NUMBER RESPONSE MFG MODEL SYMBOL K-FAC THREAD TEMP FINISH ESC QTY DRY PENDENT ADD QUICK REL F3QR *A 5.6 1" 200°F CHROME CHROME 5 TOTAL: 5 — 0—— Approved by Fire 04/12/2022 A F M /<-/ -Fla tte re r Subject to field inspection F I R2022-0035 I EXISTING SPRINKLER LEGEND I SPRINKLER PIPE LEGEND I WALL LEGEND I DESIGN CRITERIA: 1. ORDINARY HAZARD -130 SQ. FT PER SPRINKLER. 2. ALL EXISTING UPRIGHTS TO REMAIN. ELEVATIONS BOTTOM OF BRANCH LINE-10'-6" BOTTOM OF EXISTING CEILING - 11'-5" WORK AREA Sauna Hui Edmondsv m` MSHH 6onar Closet Mea�ai =uanhszn.e Furl Chinese 405 4th Ave S, G Edm onds, W A 9802E Edmonds Bowl Ace Hardware Ha,dwares Resharp EC ffiondS Autohody Al6ETWs ChLROs inc A 'r 3 a3 7 m 5� Siragic N Communities Group _ P ell Way Howell Way - Howell Way RECEIVED O EXISTING PENDENT — — — — — — - EXISTING SPRINKLER PIPE Apr 04 2022 CITY OF EDMONDS DEVELOPMENT SERVICES 0 EXISTING UPRIGHT NEW SPRINKLER PIPE VICINITY MAP DEPARTMENT SCALE: NTS 1- - FLEXIBLE HOSE NORTH �........ w--ZAsxlMeTe;NOW:■ ■.-7TT--9REMMMMMMManrE � � CERTIFICATE eF CRIMPETENCY FIRE TROY RCTIO■ Sl RIMNLKR SYSTEMS Steve Adamson C 4265-0691-C Level 3 Columbia Fire,_ LLC. ; COOLLUMFL795NJ ll 0.�� � �12M'1�2210 lgnetune � R �NEIESEIEIESESEIEItiEIMItiMIEltiElEltititiMlMlMI MINIMS Mli MK DATE 1 - - REVISIONS JOB NO. 2203130 Columbia. Fire DATE 4/01 /2022 SPRINKLIR SYSTIM SIRTICI • REPAIR DESIGNER KAI MANLEY WA CL# COLUMFI952MG 111 South Findlay Street PM MERCEDES Seattle, WA 98108 (206) 232-8569 SCALE 1/8"=1'-0" ALBERTO'S CHURROS 405 HOWELL WAY EDMONDS, WA 98020 AHJ: CITY OF EDMONDS ALBERTO'S CHURROS 405 HOWELL WAY EDMONDS, WA 98020 FIRE PROTECTION FP 1