Loading...
BLD2022-0723_Site_Plan_6.2.2022_10.02.46_PM_2908939Equipment Summary Modules: (31) LG 405W Inverter(s): (31) Enphase IQ8A Racking: Ironridge XR10 Table of Contents: Cover Page Al Site Overview A2 Roof Layout E1 Single Line E2 Electrical Calculations G1 Roof As Built G2 Electrician As -Built G3 Micro/optimizer map G4 Placards G5 Equipment BOM General Notes: Additional Electrical Work: Site IVCI. I'IGLCI A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. a� c a� �U CQ orn 1 T--I O o U •� 0 M� U � y Ln Ln — Ln i M N U a O N L O CO N •- M 4-' Oi 70 Q m�D� O 4-J U)_0 a 0 0N 0 0 N .� O M -0 '--1 LU REVISIONS Rev. #: I Date: IDesioned bv: Brian G I Project Manager: Will MacArthur (206)307-1741 Current Date:May 31, 2022 Cover Page Attachment Detail Side View (Portrait) (E) STANDING SEAM METAL ROOF Modules not to exceed height of existing ridge --- - - - -i--- - - - -- '611 Building height Manufactured trusses, 24" O.C. 181 (sample) Attachment point layout for array. 48" OC Max. &*41. A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. c a� CU a 0 M� O O) �00 Gl ' O O 2 U 0 �a U � y Ln �Ln — Ln i M N U a O N L O CO N •- M -0 Q m O Z i 0 O � ��-0 a o 00 0 N N .� O O� -0 LU REVISIONS Rev. #: I Date: Designed by: Brian G Project Manager: Will MacArthur (206) 307-1741 Current Date:May 31, 2022 Al Site Overview Required Setbacks from Ridge: ig•• Maximum Mount Spacing: 48" "A" Module and Rail Selection Guide �„�0, Roof Type: SSM Roof Slope: 180 "B" A&RSO BAR Array Tilt : Flush Array Azimuth(s): 3040 3211 Martin Luther King Jr Way S. Roof Area: 2939ftz Seattle, WA 98144 (206)707-9937 Array Area 654ftz Array to Roof Coverage 22% ***Roof Attachments/ Fastners; see pg. G5 Equip. BOM * * THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U C 4) V .7 �U a 289 1/2" 0 a O O 0) � O O N 00 O � N0 .� 01 -0 a 0 m�Z� U i �O O •� 0 V) 4 -0 a� a-6rJ 00 o U �O E — In M N U U 330 3/4" •0 L 736 1/ 2 a REVISIONS Rev. #: Date: Designed by: Brian G Project Manager: Will MacArthur (206) 307-1741 Current Date:May 31, 2022 A2 Roof Layout Net Meter LG-405 N 3 K-V6 41.02 x 74.02 Clamp Zone "A" 0-11.81" Clamp Zone "B" 9.85-15.74" Mods per Row Rail typel+ rail type2 (8)Portrait, (2)rows (2)17', (2)14' (7)Portrait, (2)rows (2)14', (2)14' (1)Landscape, (1)row (2)split 14', — — — — — — — — — — — — I -- — — — Line I _ 20A/2p Branch 1 0C O 11 modules + 20A/2p Load Branch 2 � 20A/2p I Located less than 10' 10 modules + I from net meter and I less than 10' from tap Branch 3 10 modules 0 Equipment Schedule I I �L--------- 5 Customer Owned Production Meter A ABC Ref. Category Equipment QTY 1 Modules LG-405N3K-V6 31 2 Inverters Enphase IQ8A-2-US 31 3 Jbox Jbox 2 41 LoaclCenters Enphase IQ Combiner Panel 80A, 240V 1 Breakers (3)2p2OA 5 MeterBase MeterBase-125A 4 Jaw w/ 3.5" AWCAP 1 Meter Landis Gyr EA110000-OP29 240V 1 6 Disconnect 60A 240V 2 Pole I Heavy Duty, Fuse, Lockable 1 DisconnectFuse FLNR - 60 A Fuses for Disconnect (qty 1 /pole) Monitoring Enphase IQ Monitoring 1 IIIIIIINNNNIIII10-4 Neutral Bar w/ bonding jumper Service entrance conductors 4/0 XHHW-2 (Ll & L2) 2/0 XHHW-2 (N) Supply Side Connection 705.11 (Existing) Main Service Panel (1ph 240V Service) Main Breaker: 200A Bus Rating: 200A (Existing) Main Service Panel (1ph 240V Service) Main Breaker: 200A Bus Rating:200A ■=A&RScope `„I' = Existing or A&RSOLAR Others Scope 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 CT Meter nverter Specs Watts Lw—1 Output LAI AC Voltage #of Inverters OCPQ Branch Enphase IQ8A-2-US 349 1.45 240 31 20 ****N/A**** 0 0 0 0 0 ****N/A**** 0 0 0 0 0 Module Specs WattsLwl Imp Vmp Voc Isc LG-405N3K-V6 1 405 1 10.78 1 37.6 45.3 1 11.2 Temp. Adjusted 1 0 1 0 1 33.9 49.1 1 0 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN O NOR ANY RIGHT M REPRODUCE THIS PA DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U C �U a O O) Z O O NCO I 0 C) > 01 41 -0 a o� m�Z� U i �O O •VC) ate+^U)� a°° O 0N U N0 E Ln LU .L Ln M N U a.+ U o L. a REVISIONS Rev. #: I Date: 0 Conductor Schedule General Notes: Utility: PSE 1. EGC Where exposed to physical damage will be #6AWG Bare CU 2. If installing conduit on the roof, maintain greater than 7/8" above the surface 3. NEC 690.12: Rapid Shutdown initiated by loss of Grid or AC Disconnect 4. For supply side taps, a #6 GEC (min.) will be run separately from the disconnect and connected to the grounding electrode with an irreversible crimp Designed by: Brian G Project Manager: Will MacArthur (206) 307-1741 Summary Distance (ft) Current @125% Operating Voltage Voltage Drop Volt. Drop (total) A (2)#10 CU, (1)#6 EGC, Q Cable, AIR 50 19.94A 240V 0.83% 2.02% Current Date:May 31, 2022 B (6)#10 CU, (1)#10 EGC, THWN-2, 0.75"EMT(min) 50 19.94A 240V 0.83% E1 Single Line D]1(2)#6 (2)#6 CU, (1)#8 N, (1)#10 EGC, THWN-2, 0.75"EMT(min) 10 56.19A 240V 0.18% CU, (1)#6 N, THWN-2, 1"PVC(min) 10 56.19A 240V 0.18% PV Electrical Calculations I nverter pptInput Amperage (Imp) Voltage (Vmp) Amps (DC) A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144(206)707-9937 THIS DRAWING CONSTITUTES THE JNFIDENTIAL INFORMATION OF A&R SOLAR ND ITS RECEPTOR. POSSESSION DOES NOT )NFER ANY RIGHT IN OR LICENSE TO USE IT JR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. C 9 J :Q Orn � 00 0 O 2 U � ' 3: U vu) n Ln a0 M �0 � 0 N 00 N N •- M Oi -0 >Q> m Z L � O 0�00 C a 0 N O �O E �-0 '� Lu Ref. Conductor Description Distance AL CU Wire Gauge (QTY) Phase Neutral Neutral EGC AWG ( ) Wire Type Conduit Min. Conduit 90°C Rating Temp Correct. Fill Derate Derated 75°C Rating Current Operating Voltage = Ln a N ft Conductors AWG �� TY (Q ) Type Ampacity @125% Voltage Drop A Longest Branch to Jbox 50 Cu #10 2 N/A N/A #6 QCable AIR N/A 40 1 100% 40.00 35 19.9 240 0.83% B Jbox to Combiner 50 Cu #10 6 N/A N/A #10 THWN-2 EMT 0.75 40 1 80% 32.00 35 19.9 240 0.83% C Combiner to Disconnect 10 Cu #6 2 #8 1 #10 THWN-2 EMT 0.75" 75 1 100% 75.00 65 56.2 240 0.18% D Disco. to Interconnect 10 Cu #6 2 #6 1 #6 THWN-2 PVC 1" 75 1 100% 75.00 65 56.2 240 0.18% REVISIONSDate: Rev. #: E F G H Designed by: Brian G Total Voltage Drop: 2.02% Project Manager: Will MacArthur (206)307-1741 Current Date:May 31, 2022 E2 Electrical Calculations Inverter Specs M Watts Output AC Voltage # of Inverters OCPD Total AC Comb. EGC AC � � Branch out. A OCPD Enphase IQ8A-2-US 349 1.45 240 31 20 45.0 60 #10 Ampe ****N/A**** 0 0.00 0 0 0 ****N/A**** 0 0.00 0 0 0 Module Specs W�s Imp Vmp Voc Isc Temp. Coef V(oc) DCC Volt LG-405N3K-V6 405 10.78 37.6 45.3 11.20 Max Array Specs (Adjusted for Temperature] Enphase IQ8A-2-US EnphaseIQ8A-2-US EnphaseIQ8A-2-US 1 2 3 1 2 3 1 2 3 10.78 0.00 0.00 10.78 0.00 0.00 10.78 0.00 0.00 33.9 0.0 0.0 33.9 0.0 0.0 33.9 0.0 0.0 49.1 0.0 0.0 49.1 0.0 0.0 49.1 0.0 0.0 11.20 0.00 0.00 11.20 0.00 0.00 11.20 0.00 0.00 Max Array Power(STC): 12.555 kW DC Max Continuous AC Power: 10.819kW AC Interconnection Calcs Main Breaker 200 Bus Bar 200 Max PV OCD AI lowed 40 PV OCPD Device Used 60 Tap or Breaker? Tap Site Conditions ASHRAE Site: Seattle Low Temp (°F) 19 High 2%Temp (°F) 84 High 0.4%Temp (°F) 91 Typical Placards A) NEC 2020 690.13 & 691.15 B) NEC 2020 705.12 (13)(3)(2) C) Utility Requirement D) Utility Requirement (Commercial Only) D) A&R Solar Requirement (Residential Customer -Owned) E) A&R Solar Requirement * if combiner used F) NEC 2020 690.13 (B) I) NEC 2020 690.31 (D)(2) K) NEC 2020 690.13 (B) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SOLAR ELECTRIC PV PANELS SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY L) NEC 2020 690.56 (C) *Used with Micro Inverters or DC Optimizers O) A&R Solar Requirement * if multiple inverters IAWARNING DUAL POWER SOURCE] SECOND SOURCE IS PHOTOVOLTAIC SYSTEM P) NEC 2020 705.12(C) & 690.59 R) AHJ Requirement * if combiner used S) NEC 2020 230.85(1) T) NEC 2020 230.85(3) Custom Placards �„��� A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT PLACARD SPECS QTi CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN C w NOR ANY RIGHT TO REPRODUCE THIS DR NEC 690.54 AWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. NEC 690.54 NEC 690.54 Letter Height: 1/8" Maintain 1/4" border Red / White Letter Height: 1/8" Maintain 1/4" border Red / White Letter Height: 1/8" Maintain 1/4" border Red / White 1 Branch of 11 (1) for each PV load 3 center, Disconnect, MSP/upstream 2 Branch of 10 �l U C .a U c Q O V) O 01) 00 Gl ' O O 2 U •� 0 U � Ln �Ln - Ln � N U ,—I a O N L O OD N •— M -0 Q m O Z i 0 O � ��_0 a o 00 0 N N .� O O� -0 LU REVISIONS Rev. #: I Date: Designed by: Brian G Project Manager: Will MacArthur (206)307-1741 Current Date:May 31, 2022 G4 Placards J) NEC 2020 690.56 (C)(2) PV Electrical Calculations I nverter pptInput Amperage (Imp) Voltage (Vmp) Amps (DC) A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144(206)707-9937 THIS DRAWING CONSTITUTES THE JNFIDENTIAL INFORMATION OF A&R SOLAR ND ITS RECEPTOR. POSSESSION DOES NOT )NFER ANY RIGHT IN OR LICENSE TO USE IT JR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. C 9 J :Q Orn � 00 0 O 2 U � ' 3: U vu) n Ln a0 M �0 � 0 N 00 N N •- M Oi -0 >Q> m Z L � O 0�00 C a 0 N O �O E �-0 '� Lu Ref. Conductor Description Distance AL CU Wire Gauge (QTY) Phase Neutral Neutral EGC AWG ( ) Wire Type Conduit Min. Conduit 90°C Rating Temp Correct. Fill Derate Derated 75°C Rating Current Operating Voltage = Ln a N ft Conductors AWG �� TY (Q ) Type Ampacity @125% Voltage Drop A Longest Branch to Jbox 50 Cu #10 2 N/A N/A #6 QCable AIR N/A 40 1 100% 40.00 35 19.9 240 0.83% B Jbox to Combiner 50 Cu #10 6 N/A N/A #10 THWN-2 EMT 0.75 40 1 80% 32.00 35 19.9 240 0.83% C Combiner to Disconnect 10 Cu #6 2 #8 1 #10 THWN-2 EMT 0.75" 75 1 100% 75.00 65 56.2 240 0.18% D Disco. to Interconnect 10 Cu #6 2 #6 1 #6 THWN-2 PVC 1" 75 1 100% 75.00 65 56.2 240 0.18% REVISIONSDate: Rev. #: E F G H Designed by: Brian G Total Voltage Drop: 2.02% Project Manager: Will MacArthur (206)307-1741 Current Date:May 31, 2022 E2 Electrical Calculations Inverter Specs M Watts Output AC Voltage # of Inverters OCPD Total AC Comb. EGC AC � � Branch out. A OCPD Enphase IQ8A-2-US 349 1.45 240 31 20 45.0 60 #10 Ampe ****N/A**** 0 0.00 0 0 0 ****N/A**** 0 0.00 0 0 0 Module Specs W�s Imp Vmp Voc Isc Temp. Coef V(oc) DCC Volt LG-405N3K-V6 405 10.78 37.6 45.3 11.20 Max Array Specs (Adjusted for Temperature] Enphase IQ8A-2-US EnphaseIQ8A-2-US EnphaseIQ8A-2-US 1 2 3 1 2 3 1 2 3 10.78 0.00 0.00 10.78 0.00 0.00 10.78 0.00 0.00 33.9 0.0 0.0 33.9 0.0 0.0 33.9 0.0 0.0 49.1 0.0 0.0 49.1 0.0 0.0 49.1 0.0 0.0 11.20 0.00 0.00 11.20 0.00 0.00 11.20 0.00 0.00 Max Array Power(STC): 12.555 kW DC Max Continuous AC Power: 10.819kW AC Interconnection Calcs Main Breaker 200 Bus Bar 200 Max PV OCD AI lowed 40 PV OCPD Device Used 60 Tap or Breaker? Tap Site Conditions ASHRAE Site: Seattle Low Temp (°F) 19 High 2%Temp (°F) 84 High 0.4%Temp (°F) 91